http://catalog.moeller.net CI insulated enclosures CI insulated distribution boards In many craftmen‘s and preparation workshops there are often demanding conditions for the impact resistance of the enclosures. The CI enclosure from polycarbonate offers here absolute safety for individual enclosures or wall mounting and floor-standing distribution boards. E individual enclosures - Metric cable entry knockouts in all sides - All enclosure side walls can also be knocked out over a large area - Fast conversion of individual enclosures into distribution boards Part no: CI23E-125 Page 13/6 X individual enclosures - Smooth side walls - No collection of dust and dirt Part no: CI44X-150 Page 13/7 MCB enclosures - Protection against sprayed water, dust and aggressive vapours - Complete impact resistance with high safety - The protective measure Total Insulation does not age and is therefore always effective Page 13/46 Wall-mounting and floor- standing distribution boards - With its modular construction, the box-type distribution board system up to 630 A can be easily adapted for a wide range of structural characteristics and applications. - Assembly, wiring and testing of the distribution board is carried out as standard by Moeller. As an alternative many system modules are available for self-assembly. Page 13/38 Further information and products can be found in the electronic catalogue Individual fuse enclosures, distribution board fuse enclosures, fuse enclosures with switches Enclosures with low-voltage h.b.c. fuse bases Enclosure with low voltage h.b.c. fuse switch- disconnectors CI enclosure, basic information Engineering, distribution board assembly Engineering, busbar modular system Page Technical overview 13/2 System overview 13/4 Ordering CI-E individual enclosures (empty) 13/6 CI-X individual enclosures (empty) 13/6 CI distribution board enclosure without cable gland plates 13/9 KST distribution board enclosure with cable gland plates fitted 13/9 Enclosure bases 13/13 Enclosure cover 13/14 Accessories for empty enclosures 13/15 MCB individual enclosures 13/16 MCB distribution board enclosures 13/17 MCB enclosures modular system 13/18 CI enclosures for NZM1, 2, 3 circuit-breakers and N1, 2, 3/PN1, 2, 3 switch-disconnectors 10/98 Meter enclosures 13/19 Busbar enclosures 13/21 Accessories for busbar enclosures 13/22 Busbar enclosure modular system 13/24 Mounting systems for empty enclosures 13/28 Flanges 13/30 Doors 13/31 Fitting of meters 13/32 Enclosure assembly 13/33 Metric cable glands/cable grommets 13/35 Terminals 13/36 Copper band 13/37 Distribution board assembly 13/38 Accessories for distribution board assembly 13/41 Technical data Insulated enclosures 13/45 Insulated distribution boards 13/46 Dimensions Insulated enclosures 13/48 CI insulated enclosures CI insulated enclosures Moeller HPL0211-2007/2008 Contents 13/1
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
http://catalog.moeller.net
CI insulated enclosures CI insulated distribution boards
In many craftmen‘s and preparation workshops there are often demanding conditions for the impact resistance of the enclosures. The CI enclosure from polycarbonate offers here absolute safety for individual enclosures or wall mounting and fl oor-standing distribution boards.
E individual enclosures- Metric cable entry knockouts in all
sides- All enclosure side walls can also be
knocked out over a large area- Fast conversion of individual
enclosures into distribution boards
Part no: CI23E-125
Page 13/6
X individual enclosures- Smooth side walls- No collection of dust and dirt
Part no: CI44X-150
Page 13/7
MCB enclosures- Protection against sprayed water,
dust and aggressive vapours- Complete impact resistance with high
safety- The protective measure Total
Insulation does not age and is therefore always effective
Page 13/46
Wall-mounting and fl oor-standing distribution boards- With its modular construction, the
box-type distribution board system up to 630 A can be easily adapted for a wide range of structural characteristics and applications.
- Assembly, wiring and testing of the distribution board is carried out as standard by Moeller. As an alternative many system modules are available for self-assembly.
Page 13/38
Further information and products can be found in the electronic catalogue
Individual fuse enclosures, distribution board fuse
enclosures, fuse enclosures with switches
Enclosures with low-voltage h.b.c. fuse bases
Enclosure with low voltage h.b.c. fuse switch-
disconnectors
CI enclosure, basic information
Engineering, distribution board assembly
Engineering, busbar modular system
Page
Technical overview 13/2
System overview 13/4
Ordering
CI-E individual enclosures (empty) 13/6
CI-X individual enclosures (empty) 13/6
CI distribution board enclosure without cable gland plates 13/9
KST distribution board enclosure with cable gland plates fi tted 13/9
Enclosure bases 13/13
Enclosure cover 13/14
Accessories for empty enclosures 13/15
MCB individual enclosures 13/16
MCB distribution board enclosures 13/17
MCB enclosures modular system 13/18
CI enclosures for NZM1, 2, 3 circuit-breakers and N1, 2, 3/PN1, 2, 3 switch-disconnectors 10/98
Enclosure with GS... low-voltage fuse bases Enclosures with GSTA... low-voltage h.b.c. fuseswitch disconnectors With PE/N terminals– 5th terminal can be retrofitted– NH00, NH1, NH2
GS, GSTA: a Electronic catalogue
GS00/I23E1 X 100 A, 1 X NH00GSTA00/I23E1 x 100 A, 1 x NH00
2GS00/I43E2 x 100 A, 2 x NH002GSTA00/I43E2 x 100 A, 2 x NH00
GS00-160/I43E-G1 x 160 A, 1 x NH00GSTA00-160/I43E-G1 x 160 A, 1 x NH00
GS1/I45E1 x 250 A, 1 x NH1GSTA1/I45E1 x 250 A, 1 x NH1
GS2/I45E1 x 400 A, 1 x NH2GSTA2/I45E1 x 400 A, 1 x NH2
Empty enclosuresFive frame sizes can be combinedWidth f 187.5 F 375 mmHeight f 250 F 750 mm Depth f 150 F 275 mmMetric cable entry knockouts in the sidesCover fastner with I/0 position,can be sealed, pressure relief through the built-in springTransparent cover with/without non-transparent door ,RAL 7032
a Page 13/6
Product features
•• Degree of protection IP65• Protection class 2• Distribution board system with 25 mm
grid• Modular system• Captive, sponge-rubber gaskets• Insulating wedge-lock fastener for
connecting the enclosures with each other
• Enclosures of self-extinguishing, halogen-free polycarbonate
Standards and regulations• IEC/EN 60439-1• VDE 0660 Part 500• BS 5486 part 1• NF EN 60439-1• SN EN 60439-1
Busbar system 15-conductor systemsRated operational current up to 630 ATinned copper busbars up to 630 ABusbar terminals
a Page 13/21
Fixing 2Support frame for wall mounting and floor-standing enclosuresWall fixing bracketsFixing straps
a 13/34
Cabling area 3PlinthsCable compartment cladding
a 13/42, a 13/44
Cable entries 4Gland plates for large cross-sectionsFlangesMetric cable glands/cable grommetsTerminals, copper band
a Page 13/30, a Page 13/33, a Page 13/35, a Page 13/37
Mounting systems for basic enclosures 5Sheet steel and insulating mounting platesPredrilled mounting plates for mounting standard devices
a Electronic CatalogueMounting rails and module mounting rails to IEC/EN 60715Mounting depths 125 to 250 mmMeter equipment
a Page 13/28
Enclosures with components fitted/service distribution boards (TTA)
6
MCB enclosuresFuse enclosures
a Electronic CatalogueEnclosures with low-voltage h.b.c. fuse bases a Electronic CatalogueEnclosures with low-voltage h.b.c. fuse-switch disconnectors a Electronic CatalogueCI enclosures for NZM1, 2, 3 circuit-breakers and N1, 2, 3, PN1, 2, 3 switch disconnectors
a Page 10/98
Meter enclosures
a Page 13/19
Enclosure stylesThe enclosure cover is identical for all three construction types.
CI...E-... individual enclosure• Metric cable entry knockouts in all sides• All enclosure sides can also be knocked out• Also for use in CI distribution board systems
CI...X-... individual enclosure• All four enclosure side plates walls smooth
without knockouts
CI...-... panel enclosure• Horizontal enclosure sides open• Vertical enclosure sides with large knockouts• Suitable for CI distribution board systems
Dimensions Enclosure depth:Dimensions from top:1. Mounting depth for mounting plate2. Mounting depth for mounting rails, 7.5 mm height3. Mounting depth for mounting rails, 15 mm height4. Enclosure depth
Cover Part no.Article no.
Pricesee price list
Std. pack
mm mm
Individual enclosures E and X
• Degree of protection IP65• Cover transparent or non-transparent (RAL 7032, pebble grey)• Fixing straps for wall mounting• Sealable cover fastenersE individual enclosures• With metric knockouts in all enclosure sides, side walls can be knocked outX individual enclosures• Smooth side plates, without knockouts
Dimensions Enclosure depth:Dimensions from top:1. Mounting depth for mounting plate2. Mounting depth for mounting rails, 7.5 mm height3. Mounting depth for mounting rails, 15 mm height4. Enclosure depth
Dimensions Enclosure depth:Dimensions from top:1. Mounting depth for mounting plate2. Mounting depth for mounting rails, 7.5 mm height3. Mounting depth for mounting rails, 15 mm height4. Enclosure depth
Cover Part no.Article no.
Pricesee price list
Std. pack
mm mm
Individual enclosures E and X• Degree of protection IP65• Cover transparent or non-transparent (RAL 7032, pebble grey)• Fixing straps for wall mounting• Sealable cover fastenersE individual enclosures• With metric knockouts in all enclosure sides, side walls can be knocked outX individual enclosures• Smooth side plates, without knockouts
Dimensions Enclosure depth:Dimensions from top:1. Mounting depth for mounting plate2. Mounting depth for mounting rails, 7.5 mm height3. Mounting depth for mounting rails, 15 mm height4. Enclosure depth
Cable entry External diameter
Part no.Article no.
Pricesee price list
Std. pack
mm mm mm
Distribution board with/without gland plates fitted
• Degree of protection IP65 (from below)• Sides closed, but with full area knockout, open at top• Cover transparent, cover fasteners can be sealedKST distribution board enclosure with cable gland plates fitted• Fitting of cable supports in the distribution board with wedge-lock fastner• Gland plate can be split, cables can be inserted from the front
Dimensions Enclosure depth:Dimensions from top:1. Mounting depth for mounting plate2. Mounting depth for mounting rails, 7.5 mm height3. Mounting depth for mounting rails, 15 mm height4. Enclosure depth
Cable entry External diameter
Part no.Article no.
Pricesee price list
Std. pack
mm mm mm
Distribution board with/without gland plates fitted
• Degree of protection IP65 (from below)• Sides closed, but with full area knockout, open at top• Cover transparent, cover fasteners can be sealedKST distribution board enclosure with cable gland plates fitted• Fitting of cable supports in the distribution board with wedge-lock fastner• Gland plate can be split, cables can be inserted from the front
Dimensions Enclosure depth:Dimensions from top:1. Mounting depth for mounting plate2. Mounting depth for mounting rails, 7.5 mm height3. Mounting depth for mounting rails, 15 mm height4. Enclosure depth
Dimensions Enclosure depth:Dimensions from top:1. Mounting depth for mounting plate2. Mounting depth for mounting rails, 7.5 mm height3. Mounting depth for mounting rails, 15 mm height4. Enclosure depth
Cable entry External diameter
Part no.Article no.
Pricesee price list
Std. pack
mm mm mm
Distribution board with/without gland plates fitted
• Degree of protection IP65 (from below)• Sides closed, but with full area knockout, open at top• Cover transparent, cover fasteners can be sealedKST distribution board enclosure with cable gland plates fitted• Fitting of cable supports in the distribution board with wedge-lock fastner• Gland plate can be split, cables can be inserted from the front
• For CI...E, CI...X individual enclosures• For CI... panel enclosures: at the sides, when no flange is fitted
CI48: 1 setEach set consists of 2 hinges.
DSCH-CI034224
5 off
Handle
• Quick-release fastener for opening the enclosure manuallyCI23(...)-125, 150: 4 offCI43(...)-125, 150: 4 offCI44(...)-125, 150: 4 offHigher cover in conjunction with the extension for the handle.
HG-CI046382
20 off
Extension for handle
• For cover D200-...CI43-200/(D200-CI43): 4 offCI44-200/(D200-CI44): 4 offCI48-200/(D200-CI48): 6 off
VHG50-CI044880
8 off
Sealing kit
• At the top edge of cover with D200-...Use one set diagonally per enclosure.One set consists of 2 seals.
OrderingIndividual enclosures for miniature circuit-breakers
Dimensions 1-pole MCBs PE and N terminals, quantity x cross-section
Features Part no.Article no.
Pricesee price list
Std. pack
mm Number mm2
Individual enclosures for miniature circuit-breakers
• Metric cable entry knockouts in all sides• Degree of protection IP65• For flush mounting devices with frame size 1 to DIN 43880• Transparent cover with quick-release fasteners, transparent door for operator access to devices fitted• Mounting rails for snap-fitting the devices• Blanking strip for unused locations, protective shroud with inscription label• PE/N bars• Fixing straps for wall mounting, cover fasteners can be sealed• Enclosure depth 150 mm
OrderingPanel enclosures for miniature circuit-breakers
CI in
sula
ted
encl
osur
es
Dimensions Enclosure depth 1-pole MCBs Part no.Article no.
Pricesee price list
Std. pack
mm mm Number
Panel enclosures for miniature circuit-breakers
• Sides closed, but with full area knockout, open top and bottom• Degree of protection IP65• For flush mounting devices with frame size 1 to DIN 43880• Transparent cover with quick-release fasteners• Mounting rails for snap-fitting the devices• Blanking strip for unused locations, protective shroud with inscription label• Fixing straps for wall mounting, cover fasteners can be sealed
Dimensions Enclosure depth:Dimensions from top:1. Meter rail2. Enclosure depth
Features Part no.Article no.
Pricesee price list
Std. pack
mm mm
Meter enclosures, meter railMeter enclosures• Metric cable entry knockouts in all sides (Exception: ZG/I48-200)• Degree of protection IP65• Cover/door transparent• ZG/I48-200 top and bottom with full area knockouts for FL4... flange• Meter rail to DIN 43853 including meter fixing screws and nuts• Fixing strap for wall mounting• Sealable fasteners at the top edge of the cover
• Degree of protection IP65• Cover transparent• Top and bottom with full-area knockouts• Sides closed, but with full-area knockouts• Fixing straps for wall fixing• Cover fasteners can be sealed• Enclosure depth 225 mm• 50 mm between busbar centres
250 L1, L2, L3, PEN 1,34 SKA254-I44034221
1 off
400 L1, L2, L3, PEN 2,35 SKA404-I44034220
630 L1, L2, L3, PEN 3,69 SKA634-I44090135
250 L1, L2, L3, PE, N 1,68 SKA255-I44034209
400 L1, L2, L3, PE, N 2,68 SKA405-I44034208
630 L1, L2, L3, PE, N 4,36 SKA635-I44090138
250 L1, L2, L3, PEN 2,68 SKA254-2I44034207
400 L1, L2, L3, PEN 4,69 SKA404-2I44034204
630 L1, L2, L3, PEN 7,37 SKA634-2I44090141
250 L1, L2, L3, PE, N 3,35 SKA255-2I44034203
400 L1, L2, L3, PE, N 5,36 SKA405-2I44034202
630 L1, L2, L3, PE, N 8,71 SKA635-2I44090144
Busbar coupling kits
including sealing and fixing material 250 – 630 L1, L2, L3, PE, N 0,00 SVS250630-5002066
1 off
1000 L1, L2, L3 for copper busbars 2 x 30 x 10 mm
0,00 AVS30L093842
3 off
500 PE, N, PEN for copper busbars 30 x 10 mm
0,00 AVS30PEN096215
2 off
1600 L1, L2, L3 for copper busbars 3 x 40 x 10 mm
0,00 AVS40098588
3 off
Notes1) Calculating extra material cost a General section2)
• Degree of protection IP65• Door opening angle to 180°• Hinge position can be changed by customer to right, left, top or bottom• Adhesive film for marking cutout• Fixing screws• Transparent
CI23..., D...-CI23 T-CI23093833
2 off
CI43..., D...-CI43: 1 xCI45..., D...-CI45: 2 x
T-CI43096206
CI44..., D...-CI44: 1 xCI48..., D...-CI48: 2 x
T-CI44098579
Hinged flaps
• For positioning on cover, change as required• Degree of protection IP55.• Opening angle to 180°• Hinge on one side cannot be changed
145 x 80 mm K-A043372
1 off
185 x 90 mm KG-A055244
1 off
Mounting depth: For use with Part no.Article no.
Pricesee price list
Std. pack
mm
Covers with door
• Degree of protection IP65125 U-CI23... D125-CI23/T
Meter shroudsin CI43E-200, CI44E-250 enclosuresFor snap fitting of 96 x 96 mm meters, max. 6 off.The meter shroud is secured using AH-GA support brackets.
CI43E-200 and CI44E-200 enclosures GA-MS-I43053502
1 off
CI44E-250 enclosure GA-MS-I44055875
1 off
CI44E-200 enclosuresFor snap fitting of 96 x 96 mm meters, max. 6 off.The meter shroud is secured using AH-GA support brackets.
CI44E-200 enclosure GA-RS-I44022653
2 off
CI43E-200 and CI44E-200 enclosures GA-MS-I43053502
1 off
Set of support bracketsFor meters and protective shrouds(Order GA-MS-143 meter shroud separately)Each set consists 4 brackets.
AH-GA002305
10 off
Set of support bracketsTo blank off unused spaces:Also required as an adapter with snap-fittting 72 x 72 mm meters and when fitting PKZM0 (voltmeters) as well as T0-... (meter changeover switch)(Order GA-MS-143 meter shroud separately)
HBA-4344002316
10 off
Fixing kitsFor fitting PKZM0. T0, max. 2 offFitting parallel to 250 mm side of the enclosure.(Order GA-MS-143 meter shroud separately)
BFS-PT3002317
5 off
For fitting PKZM0. T0, max. 3 offFitting parallel to 375 mm side of the enclosure.(Order GA-MS-143 meter shroud separately)
• For securing CI enclosures directly to the wall• For up to 4 x CI43... enclosures
Each set contains 4 straps BL-CI036168
5 off
Steel version V2A Each set contains 4 straps BL-CI-VA038541
5 off
Wall fixing brackets
• For securing CI enclosures at a distance of 50 mm from the wall• Fit one wall fixing bracket to every second enclosure across the width; for transport purposes add more brackets at
the bottom.Section length 2125 mm, cut to fit. W16/32
0901461 off
Max. 2 x CI43 one above the other W4/8048755
Max. 2 x CI44 one above the other W6/12051128
Max. 4 x CI43 one above the other W8/16053501
Max. 5 x CI43 one above the other W10/20055874
Fixing screwFor securing CI enclosures on the W... wall fixing bracketsFor securing CI enclosures on WS..., WW... profiles
LT284-M6X20-C050325
100 off
Connecting bracketEnclosure assembly and flange connection,K-CI required
VS-CI002315
100 off
For attatching gland plates,K-CI required
VS-KS-CI038460
25 off
WedgeWith VS-CI or VS-KS-CI for enclosure assembly and attaching flanges and gland plates
K-CI002314
100 off
BracketEnclosure assemblies, enclosure dimension 375 mm KD4-CI
00231325 off
Gaskets
For enclosure assemblyEnclosure dimension 187.5 mm D2-CI
Example of application: NYM/NYY cable, 4-core Part no.Article no.
Pricesee price list
Std. pack
mm mm mm2
Metric diaphragm grommets
• IP66, with built-in push-through diaphragm• PE and thermoplastic elastomer, halogen-free
M16 16.5 1 … 9 H03VV-F3 x 0.75 mm2, NYM 1 x 16/3 x 1.5 mm2 KT-M16216983
100 off
M20 20.5 1 – 13 H03VV-F3 x 0.75 mm2, NYM 5 x 1.5/5 x 2.5 mm2 KT-M20207602
M25 25.5 1 – 18 H03VV-F 3 x 0.75 mm2, NYM 4 x 10 mm2 KT-M25207603
M32 32.5 1 … 25 H03VV-F 3 x 0.75 mm2, NYM 4 x 16/5 x 10 mm2 KT-M32207604
Metric cable glands to EN 50262Metric cable glands• With lock nut and built-in strain relief• IP68 up to 5 bar, polyamide, halogen-free• Flammability classification V2 to UL94
M12 12.5 3 … 7 H03VV-F 3 x 0.75 mm2, NYM 1 x 2.5 mm2 V-M12215078
20 off
M16 16.5 4.5 … 10 H05VV-F 3 x 1.5 mm2, NYM 1 x 16/3 x 1.5 mm2 V-M16215077
M20 20.5 6 – 13 H05VV-F 4 x 2.5/3 x 4 mm2, NYM 5 x 1.5/5 x 2.5 mm2 V-M20206910
M25 25.5 9 – 17 H05VV-F 5 x 2.5/5 x 4 mm2, NYM 5 x 2.5/5 x 6 mm2 V-M25206911
M32 32.5 13 – 21 NYM 5 x 10 mm2 V-M32206912
10 off
M32 32.5 18 – 25 NYM 5 x 16 mm2 V-M32G1)
226156M40 40.5 16 … 28 NYM 5 x 16 mm2 V-M40
209668
M50 50.5 21 … 35 NYM 4 x 35/5 x 25 mm2 V-M50206913
5 off
M63 63.5 34 … 48 NYM 4 x 35 mm2 V-M63214835
3 off
Multiple gasketsM25 – 4 x
5 … 6H03VV-F 2 x 0.75/3 x 0.75 mm2 MFD25
21545125 off
M32 – 4 x 3.5 … 7
H03VV-F 4 x 0.75 mm2 MFD32215452
25 off
Stoppers for unused openings in MFD... multiple gasketsM25 – MFV25-6
21545350 off
M32 – MFV32-7215454
50 off
Cable grommets
For wall thickness 2 – 3 mm, PVC58 14 … 54 KT3
0315232 off
75 14 … 68 KT4036269
3 off
Pressure compensating grommet/ventilation glandVentilation grommet with filter, metricFor use in the enclosure bottom or sides, PE and PVC
M25 25.5 KT-M25F224556
50 off
Ventilation cable gland IP56• Permeable to air, un-permeable to dust• For the prevention of condensationFor use in the enclosure bottom or sides, polyamide, halogen free
Dimensions (Number of layers x width x thickness of a layer)
Cross-section2) Cu factor3) Part no.Article no.
Pricesee price list
Std. pack
Ie
A mm mm2
Tinned copper band, conductor: E-CU
• Rated voltage 690 V AC• UL approved up to max. 600 V AC• Dielectric strength 20 kV/mm• Insulating material heat resistant up to +105 °C• Expansion 370 %• Self-extinguishing to UL 94 V 0• 2000 mm long, black (BK), blue (BU) and green/yellow (GNYE).
100 3 x 9 x 0.8 21.6 0,41 CU-BAND3X9X0,8-BK081167
20 off
100 3 x 9 x 0.8 21.6 0,41 CU-BAND3X9X0,8-GNYE081006
100 3 x 9 x 0.8 21.6 0,41 CU-BAND3X9X0,8-BU080960
160 6 x 9 x 0.8 43.2 0,83 CU-BAND6X9X0,8-BK081414
10 off
160 6 x 9 x 0.8 43.2 0,83 CU-BAND6X9X0,8-GNYE081367
160 6 x 9 x 0.8 43.2 0,83 CU-BAND6X9X0,8-BU081344
200 9 x 9 x 0.8 64.8 1,24 CU-BAND9X9X0,8-BK081515
200 9 x 9 x 0.8 64.8 1,24 CU-BAND9X9X0,8-GNYE081485
200 9 x 9 x 0.8 64.8 1,24 CU-BAND9X9X0,8-BU081436
250 6 x 16 x 0.8 74.4 1,43 CU-BAND6X16X0,8-BK081310
250 6 x 16 x 0.8 74.4 1,43 CU-BAND6X16X0,8-GNYE081275
250 6 x 16 x 0.8 74.4 1,43 CU-BAND6X16X0,8-BU081222
400 10 x 16 x 0.8 124 2,38 CU-BAND10X16X0,8-BK080739
5 off
400 10 x 16 x 0.8 124 2,38 CU-BAND10X16X0,8-GNYE080698
400 10 x 16 x 0.8 124 2,38 CU-BAND10X16X0,8-BU079736
630 11 x 21 x 1 231 4,44 CU-BAND11X21X1-BK080923
630 11 x 21 x 1 231 4,44 CU-BAND11X21X1-GNYE080836
630 11 x 21 x 1 231 4,44 CU-BAND11X21X1-BU080769
Notes 1) Rated operational current: conform to VDE 02812) Cross-section: wiring instructions for devices (e.g. terminal capacity at least ... mm) must be given priority3) Calculating extra material cost a General section
OrderingAccessories for distribution board assembly
For use with Use Part no.Article no.
Pricesee price list
Std. pack
Cross plates for wall-mounting and floor-standing distribution boards
• For connection of horizontal and vertical section• Including fixing sundries
KVB-ID002300
10 off
Assembly bracket
• For connection of distribution boards and for transport units• Including fixing sundries
Wall-mounting distribution system top and bottom on WW... sectionWall-mounting distribution boards 2 off, floor-standing enclosure 1 off
ARB-ID002302
10 off
Lifting eye fixing
For securing TOR-GG lifting eyes, M12 threadWall-mounting distribution boards, floor-standing distribution boardsMounting in WS... vertical profiles
– TOB-ID093848
10 off
Lifting eyes kit
For securing lifting eyes, M12 threadWall-mounting distribution boards, floor-standing distribution boardsFor fixing using TOB-ID to the vertical sectionsOne set consists of 4 lifting eyes.
– TOR-GG048276
1 off
Fixing screws
For secure CI enclosures to the frame sectionsFor securing CI enclosures on the W... wall fixing bracketsFor securing CI enclosures on WS..., WW... profiles
– LT284-M6X20-C050325
100 off
Plinths
For fitting floor-standing distribution boardsWidth 375 mm – SS5-ID0375
GeneralComponents Switchgear assembly components are type-tested. They are available
individually for the self-assembly of switchgear installations, distribution boards and control panels.
Devices that can be fitted The reference values indicated in the table apply to the basic elements of the distribution board. As far as devices, terminals etc. fitted into the enclosures are concerned, their own specific technical data and rated values apply.
StandardsTTA – Type Tested Assemblies IEC/EN 60439-1, VDE 0660 Part 500
Low-voltage fuses IEC/EN 60269, VDE 0636Type test VDE 0660 Part 500, IEC/EN 60439-1Creepage and clearance distances III/3 to IEC/EN 60439-1Flammability characteristics – Glow rod test VDE 0304 Part 3 level IIb, level IIb to IEC 60707Regulation for the fire resistance tests of electrical products, their modules and components, glow wire test
VDE 0471 Part 2
Operating and ambient conditions to VDE 0660 Part 500Ambient temperature
Mean value over 24 hours °C 35Limit values °C -5…40
Indoor installationRelative humidity
at 20 °C % 90at 40 °C % 50
Altitude m 2000Degree of protection
CI enclosure IP 65KST cable entry from below IP 65KST cable entry from above IP64Cable entry, open IP00
Modular grid mm 25 (DIN 43660)Colour
Base RAL 7032, pebble greyCover Transparent, colourless or RAL 7032, pebble grey
Surface protection for metals Galvanized, passivatedDissipatable heat loss a page 13/47
Electrical characteristicsBusbar system
Rated operational voltage Ue V AC 690 690 690 690Rated insulation voltage
AC Ui V AC 690 690 690 690DC Ui V DC 800 800 800 800
Rated operational current Ie A 160 250 400 630Rated short-time withstand current
t = 0.1 s c = 0.2 Icw kA 20 25 35 40t = 1 s Icw kA 4 7 14 28Rated peak withstand current Ipk kA 40 52.5 73.5 84
Distance between busbar supports mm 375 375 375 375
Notes When calculating the heat dissipation, the quadratic relationship of current with the rated diversity factor a must be considered.Pv = I 2 x RPv’ = Pv x a 2
If no data is available concerning the load relationships of the individual circuits, the rated diversity factor is selected conform to VDE 0660 Part 500.
KT-M… V-M… MFD… MFV… KT-M25F STB-M…F
Material Polyethylen and thermoplastic elastomer
Polyamide, halogen free
Thermoplastic elastomer
Polyamide PVC and polyethylene
Glass-fibre reinforced polyamide with flame protection, self-extinguishing
Colour Grey, RAL 7035 Grey, RAL 7035 Black, similar to RAL 9005
Red Grey, RAL 7032 + white
Grey, RAL 7035
Degree of protection up to IP66 IP68 up to 5 bar(30 min)
IP66 – up to IP50 IP56, mounting only on the bottom side of enclosure
Chemical resistant Resistant against: Alcohol, animal and plant fat, brine, light acids, water
Resistant against : Acetone, petrol, paraffin, diesel, grease, oil, solvent for paints and varnishes
– – Resistant against, diluted non-oxidising acids, lye and salt, alcohol, aromatic and halogen-free hydrocarbon, surfactant.
Resistant against : Acetone, petrol, paraffin, diesel, grease, oil, solvent for paints and varnishes
Danger of stress fracture Relative high low – – Relative high low
Heat resistance –40 °C…80 °C, short-time up to approx. 100 °C
–20 °C…100 °C, short-time up to approx. 120 °C
–25 °C…100 °C, short-time up to approx. 120 °C
–25 °C…80 °C, short-time up to approx. 120 °C
0 °C…60 °C, short-time up to 80 °C
–40 °C…100 °C, short-time up to approx. 150 °C
Flame retardant – Glow wire test 750 °C according to EN 60695-2-11
– – – Glow wire test 750 °C according to EN 60695-2-11