Top Banner
1/2 TECHNICAL SPECIFICATIONS Self Discharge Short Circuit Current Approx. Weight Terminal Type Max. Charge Current Internal Resistance Max. Discharge Current (5S) Container Material Nominal Voltage (V) Dimension (mm) Ambient Temperature o Designed Floating Life (25 C) o Nominal Capacity (25 C) 12 V voltage AGM tech 5 years design life 26Ah capacity Float Charge Voltage Equalize and cycle Use Charge Voltage Complied standards IEC 60896-21/22 GB/T19638 JIS C8704 BS6290 part 4 ) l a n o i t p o 0 V - 4 9 ( L U S B A 5 Years 12 (6 cells per unit) 26 Ah @ 20 -rate (to 1.75Vpc) HR o 14. V @25 C 4 o o 13.6V @25 C (-3mV/ cell/ C) Approx. 2.5% per month @ 20° C 1000 A 7 8 17 2 . kg ( . lbs) 7.2 A 310 A Approx. 0.0 Ohm (fully charged @ 25° C) 10 L1 mm x W mm x H1 mm 75 166 25 Charge: - ~ °C 20 50 Storage: - ~45° C 20 Discharge: - ~55° C 20 BATTERY DIMENSIONS BATTERY DISCHARGE TABLE Female Copper Insert M5 (torque:4~6N.m) M5mm m m 5 . 0 175mm 166mm 5 m m 2 1 Terminal 5 min 10 min 15 min 30 min 1h 2h 3h 4h 5h 8h 10h 20h 1.60 V 72.9 53.8 44.4 27.3 16.4 9.54 6.86 5.49 4.57 3.12 2.58 1.39 1.67 V 65.0 49.6 41.9 26.1 16.0 9.36 6.80 5.42 4.51 3.08 2.55 1.35 1.70 V 58.1 45.0 39.5 25.1 15.6 9.23 6.74 5.36 4.48 3.04 2.51 1.32 1.75 V 50.5 41.9 36.7 24.3 15.3 9.11 6.62 5.30 4.42 3.00 2.48 1.30 1.80 V 44.6 38.0 34.3 23.2 Constant Current Discharge Characteristics: Amps (25°C) F.V /T ime 14.8 8.87 6.50 5.18 4.31 2.93 2.43 1.28 1.85 V 38.2 34.3 31.2 21.9 14.2 8.57 6.26 5.03 4.21 2.87 2.37 1.25 F.V /T ime 5min 10 min 15 min 30 min 1h 2h 3h 4h 5h 8h 10h 20h 1.60 V 128 96.6 80.8 50.5 30.6 17.9 13.0 10.4 8.69 6.00 4.98 2.69 1.67 V 116 89.9 77.1 48.6 30.0 17.7 12.9 10.3 8.69 5.96 4.94 2.65 1.70 V 105 82.6 73.5 47.1 29.5 17.6 12.9 10.3 8.63 5.93 4.91 2.61 1.75 V 92.3 77.8 68.6 45.9 29.1 17.4 12.8 10.3 8.63 5.89 4.88 2.58 1.80 V 82.6 71.7 65.0 44.3 Constant Power Discharge Characteristics: W/cell (25°C) 28.4 17.3 12.6 10.1 8.44 5.80 4.83 2.55 1.85 V 71.7 65.0 59.6 42.2 27.5 16.7 12.3 9.90 8.32 5.71 4.73 2.50 KB1226 12V 26Ah Kaise Battery series are Top terminal VRLA AGM battery for General use. With advanced manufacturing technique and industry scale, KB series delivers high energy density and high reliability performance, highly suited for UPS systems, security and alarm systems, telecommunication, utilities, emergency light systems, CATV and other backup applications.
2

KAISE-KB1226-hresys - ARG

Jun 01, 2022

Download

Documents

dariahiddleston
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: KAISE-KB1226-hresys - ARG

1/2

TECHNICAL SPECIFICATIONS

Self Discharge

Short Circuit Current

Approx. WeightTerminal Type

Max. Charge CurrentInternal Resistance

Max. Discharge Current (5S)

Container Material

Nominal Voltage (V)

Dimension (mm)

Ambient Temperature

oDesigned Floating Life (25 C)oNominal Capacity (25 C)

12 Vvoltage

AGMtech

5 yearsdesign life

26Ahcapacity

Float Charge Voltage

Equalize and cycle Use Charge Voltage

Complied standardsIEC 60896-21/22GB/T19638JIS C8704BS6290 part 4)lanoitpo 0V-49( LUSBA

5 Years

12 (6 cells per unit)

26 Ah @ 20 -rate (to 1.75Vpc)HR

o14. V @25 C4

o o13.6V @25 C (-3mV/ cell/ C)

Approx. 2.5% per month @ 20° C1000 A

7 8 17 2. kg ( . lbs)

7.2 A

310 A

Approx. 0.0 Ohm (fully charged @ 25° C)10

L1 mm x W mm x H1 mm75 166 25

Charge: - ~ ° C20 50Storage: - ~45° C20

Discharge: - ~55° C20

BATTERY DIMENSIONS

BATTERY DISCHARGE TABLE

Female Copper Insert M5 (torque:4~6N.m)

M5mmmm5.0

175mm166mm

5m

m21

Terminal

5 min 10 min 15 min 30 min 1h 2h 3h 4h 5h 8h 10h 20h1.60 V 72.9 53.8 44.4 27.3 16.4 9.54 6.86 5.49 4.57 3.12 2.58 1.391.67 V 65.0 49.6 41.9 26.1 16.0 9.36 6.80 5.42 4.51 3.08 2.55 1.351.70 V 58.1 45.0 39.5 25.1 15.6 9.23 6.74 5.36 4.48 3.04 2.51 1.321.75 V 50.5 41.9 36.7 24.3 15.3 9.11 6.62 5.30 4.42 3.00 2.48 1.301.80 V 44.6 38.0 34.3 23.2

Constant Current Discharge Characteristics: Amps (25°C)F.V /T ime

14.8 8.87 6.50 5.18 4.31 2.93 2.43 1.281.85 V 38.2 34.3 31.2 21.9 14.2 8.57 6.26 5.03 4.21 2.87 2.37 1.25

F.V /T ime 5 min 10 min 15 min 30 min 1h 2h 3h 4h 5h 8h 10h 20h1.60 V 128 96.6 80.8 50.5 30.6 17.9 13.0 10.4 8.69 6.00 4.98 2.691.67 V 116 89.9 77.1 48.6 30.0 17.7 12.9 10.3 8.69 5.96 4.94 2.651.70 V 105 82.6 73.5 47.1 29.5 17.6 12.9 10.3 8.63 5.93 4.91 2.611.75 V 92.3 77.8 68.6 45.9 29.1 17.4 12.8 10.3 8.63 5.89 4.88 2.581.80 V 82.6 71.7 65.0 44.3

Constant Power Discharge Characteristics: W/cell (25°C)

28.4 17.3 12.6 10.1 8.44 5.80 4.83 2.551.85 V 71.7 65.0 59.6 42.2 27.5 16.7 12.3 9.90 8.32 5.71 4.73 2.50

KB1226 12V 26Ah

Kaise Battery series are Top terminal VRLA AGM battery for General use. With advanced manufacturing technique and industry scale, KB series delivers high energy density and high reliability performance, highly suited for UPS systems, security and alarm systems, telecommunication, utilities, emergency light systems, CATV and other backup applications.

Page 2: KAISE-KB1226-hresys - ARG

2 2/

CHARACTERISTICS

FINAL VOLTAGE SETTINGS RECOMMENDEDACCORDING TO THE DISCHARGE CURRENT

Dis charge Current I (A)Final of Voltage

I1.85Vpc 1.80Vpc 1.75Vpc 1.70Vpc 1.60Vpc

0.08C I<0.2C 0.2C I<0.6C 0.6C I<1.0C I 1.0C

2.17

2.00

1.83

1.67

1.60

1.33

0 2 6 12 30 60 3 10 20Min Hour

1CA 0.55CA

0.25CA0.1CA 0.05CA

ODischarge Characteristic (2 C)5

Storage time(months)

201812 1610 1486420

)%( yticapa

C

0

20

40

60

80

100

120

Self ischarge haracteristicsD C

o40 C o30 C o20 C

0

0.05

60

40

0 2

100

120

80

AC )(

84 6 10 12

ChargeCapacity

ChargeVoltage

Charge Current

2.40

2.20

2.00

1.80

egrahC

tnerruC

egrahC

(%)oConstant Charge at 0.25 -2.40V (2 C)CA 5

0.10

0

20

60

400.15

0.25

0 2

100

120

80

(V/Cell)

84 6 10 12

Charge Characteristic

ChargeCapacity

ChargeVoltage

100%Discharge

Charge Current

Time(hour)

0

yticapaC

egrahC

egatloV

50%Discharge0.20

2CA3CA

o5 C

Temperature vs Float Life

Float Voltage (V/cell)2.10 2.20 2.30 2.40 2.50

100

80

60

40

20

0

)%( efiL taolF

2.25V/cell

Test Procedure:Temp:20~25�Discharge :0.25CACut-off Voltage:1.75V/cellEnd of life: 60% of nominal capacity

Float voltage vs Float life

)sraey(efiL

oTemperature ( C )

0

20

40

60

80

100

120

-20 -10 0 10 20 30 40 50

Temperature (° C)

Capacity vs Temperature

)%( yticapa

C

0

1

2

3

4

5

6

20 25 30 35 40 45 50

KB1226 12V 26Ah