July '19 PLANNING DRAWINGS - Kilkenny · elevation3-3. new access through existing masonry wall, existing wall to be removed existing wall to be retained and reduced in height existing
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
R:\M
CT0
759
- Eirs
pan
TO30
2 N
78 C
astle
com
er F
ootb
ridge
\8.0
Dra
win
gs\P
l\MC
T075
9PL0
100.
dwg
Drn
Chk
Client
Rev Date Amendment / Issue AppModel File Identifier File Identifier
Sheets
Created on
Scale Project
Title
Status Rev
(iii) This drawing is the property of RPS, it is a projectconfidential classified document. It must not be copied usedor its contents divulged without prior written consent. Theneeds and expectations of client and RPS must beconsidered when working with this drawing.
(iv) Information including topographical survey,geotechnical investigation and utility detail used in thedesign have been provided by others.
General Notes(i) Hard copies, dwf and pdf will form a controlled issue of the drawing.
All other formats (dwg etc.) are deemed to be an uncontrolled issueand any work carried out based on these files is at the recipientsown risk. RPS will not accept any responsibility for any errors fromthe use of these files, either by human error by the recipient, listingof the un-dimensioned measurements, compatibility with therecipients software, and any errors arising when these files areused to aid the recipients drawing production, or setting out on site.
Eirspan Task Order No. 302 N78, Castlecomer FootbridgeJuly '19
PLANNING DRAWINGS
COUNCILCOUNTYKILKENNY
COUNCILCOUNTYKILDARE
INDEX SHEETMCT0759PL0100-01
PROPOSED OPTION (Sheet 1 of 3)PROPOSED OPTION (Sheet 2 of 3)
MCT0759PL0102-01MCT0759PL0102-02
LOCATION PLANMCT0759PL0101-01
PROPOSED OPTION (Sheet 3 of 3)MCT0759PL0102-03
PROPOSED SITEBOUNDARY
(Scale 1 : 50,000)
Footbridge
LOCATION PLAN 1 : 50,000(Scale 1 : 2,500)
Footbridge
LOCATION PLAN 1 : 2,500
R:\M
CT0
759
- Eirs
pan
TO30
2 N
78 C
astle
com
er F
ootb
ridge
\8.0
Dra
win
gs\P
l\MC
T075
9PL0
101.
dwg
Drn
Chk
Client
Rev Date Amendment / Issue AppModel File Identifier File Identifier
Sheets
Created on
Scale Project
Title
Status Rev
(iii) This drawing is the property of RPS, it is a projectconfidential classified document. It must not be copied usedor its contents divulged without prior written consent. Theneeds and expectations of client and RPS must beconsidered when working with this drawing.
(iv) Information including topographical survey,geotechnical investigation and utility detail used in thedesign have been provided by others.
General Notes(i) Hard copies, dwf and pdf will form a controlled issue of the drawing.
All other formats (dwg etc.) are deemed to be an uncontrolled issueand any work carried out based on these files is at the recipientsown risk. RPS will not accept any responsibility for any errors fromthe use of these files, either by human error by the recipient, listingof the un-dimensioned measurements, compatibility with therecipients software, and any errors arising when these files areused to aid the recipients drawing production, or setting out on site.
EXISTING MASONRYPIER AND ENTRANCEGATE TO BERETAINED
NEW ACCESSTHROUGH EXISTINGMASONRY WALL,EXISTING WALL TOBE REMOVED
NEW MASONRY WALLBETWEEN THE EXISTINGMASONRY GATE PIER ANDRIVER, 2.1m HIGH OVERACCESS RAMP
EXISTING LAWN
DININ RIVER
EXISTING WEIR TOBE RETAINED
EXISTING RIVERSIDEWALL TO BERETAINED / REBUILTUNDER BRIDGE
EXISTING BRIDGEPARAPET TO BERETAINED
NEW ACCESSTHROUGH EXISTINGMASONRY WALL,EXISTING WALL TOBE REMOVED
RAISED BANK AREA
1-1
2-2
3-3
EXISTING LIGHTINGCOLUMN TO BERELOCATED
EXISTING WALL TOBE RETAINED ANDREDUCED IN HEIGHT
EXISTING ROADSIGNS TO BERELOCATED
EXISTING LIGHTINGCOLUMN TO BERELOCATED
FLO
W
PROPOSEDINFORMATIONBOARD
PROPOSED LIGHTINGCOLUMN
EXISTING RUBBINGSTRIP TO TAKEN UPAND RELAID
PROPOSEDBOLLARDS
PROPOSEDBOLLARDS
EXISTING WALL TO BE REMOVED
EXISTING WALL TO BE RETAINED
HANDRAIL
NEW PEDESTRIAN ACCESS
NEW WALL
LEGEND :-
EXISTING WALL TO BE RETAINEDAND REDUCED IN HEIGHT
PROPOSED SITE BOUNDARY
ELEVATION1-1
NEW ACCESSTHROUGH EXISTINGMASONRY WALL
DININ RIVER
EXISTING LAWN
EXISTING WEIR TOBE RETAINED
RAISED BANK AREA
EXISTING RIVERSIDEWALL TO BERETAINED / REBUILTUNDER BRIDGE
NEW MASONRY WALL BETWEENTHE EXISTING MASONRY GATEPIER AND RIVER, 2.1m HIGHOVER ACCESS RAMP
EXISTING MASONRYPIER AND ENTRANCEGATE TO BERETAINED
EXISTING BRIDGEPARAPET TO BERETAINED
NEW ACCESSTHROUGH EXISTINGMASONRY WALL
ABUTMENT AND WALL TOBE MASONRY CLAD.MASONRY TO MATCHEXISTING BRIDGE
EXISTING BRIDGE NICHESAND EASTERN SPANDRELWALL TO BE ILLUMINATED
TP
115.37
Pipe Invert
diam=0.30
115.45
Pipe Invert
diam=0.30
TIC
G
113.76
TP
112.59
Pipe Invert
diam=0.3
PROPOSEDSITEBOUNDARY
PROPOSED LAYOUT(Scale 1 : 100)
R:\M
CT0
759
- Eirs
pan
TO30
2 N
78 C
astle
com
er F
ootb
ridge
\8.0
Dra
win
gs\P
l\MC
T075
9PL0
102.
dwg
Drn
Chk
Client
Rev Date Amendment / Issue AppModel File Identifier File Identifier
Sheets
Created on
Scale Project
Title
Status Rev
(iii) This drawing is the property of RPS, it is a projectconfidential classified document. It must not be copied usedor its contents divulged without prior written consent. Theneeds and expectations of client and RPS must beconsidered when working with this drawing.
(iv) Information including topographical survey,geotechnical investigation and utility detail used in thedesign have been provided by others.
General Notes(i) Hard copies, dwf and pdf will form a controlled issue of the drawing.
All other formats (dwg etc.) are deemed to be an uncontrolled issueand any work carried out based on these files is at the recipientsown risk. RPS will not accept any responsibility for any errors fromthe use of these files, either by human error by the recipient, listingof the un-dimensioned measurements, compatibility with therecipients software, and any errors arising when these files areused to aid the recipients drawing production, or setting out on site.
Rev Date Amendment / Issue AppModel File Identifier File Identifier
Sheets
Created on
Scale Project
Title
Status Rev
(iii) This drawing is the property of RPS, it is a projectconfidential classified document. It must not be copied usedor its contents divulged without prior written consent. Theneeds and expectations of client and RPS must beconsidered when working with this drawing.
(iv) Information including topographical survey,geotechnical investigation and utility detail used in thedesign have been provided by others.
General Notes(i) Hard copies, dwf and pdf will form a controlled issue of the drawing.
All other formats (dwg etc.) are deemed to be an uncontrolled issueand any work carried out based on these files is at the recipientsown risk. RPS will not accept any responsibility for any errors fromthe use of these files, either by human error by the recipient, listingof the un-dimensioned measurements, compatibility with therecipients software, and any errors arising when these files areused to aid the recipients drawing production, or setting out on site.
(Sheet 2 of 3)P01 July'19 DCEC Issue For Planning AO'B
AutoCAD SHX Text
PL0102-01
AutoCAD SHX Text
(Scale 1 : 25)
AutoCAD SHX Text
BR0102-01
AutoCAD SHX Text
(Scale 1 : 50)
PHOTOMONTAGE 1 PROPOSED OPTION
R:\M
CT0
759
- Eirs
pan
TO30
2 N
78 C
astle
com
er F
ootb
ridge
\8.0
Dra
win
gs\P
l\MC
T075
9PL0
102.
dwg
Drn
Chk
Client
Rev Date Amendment / Issue AppModel File Identifier File Identifier
Sheets
Created on
Scale Project
Title
Status Rev
(iii) This drawing is the property of RPS, it is a projectconfidential classified document. It must not be copied usedor its contents divulged without prior written consent. Theneeds and expectations of client and RPS must beconsidered when working with this drawing.
(iv) Information including topographical survey,geotechnical investigation and utility detail used in thedesign have been provided by others.
General Notes(i) Hard copies, dwf and pdf will form a controlled issue of the drawing.
All other formats (dwg etc.) are deemed to be an uncontrolled issueand any work carried out based on these files is at the recipientsown risk. RPS will not accept any responsibility for any errors fromthe use of these files, either by human error by the recipient, listingof the un-dimensioned measurements, compatibility with therecipients software, and any errors arising when these files areused to aid the recipients drawing production, or setting out on site.