Top Banner
JSW1 INSTALLATION AND USE Suitable for use with clean water and with liquids that are not chemically aggressive towards the materials from which the pump is made. The self-priming JSW pumps are designed to pump water even in cases where air is present. Because of their reliability and the fact that they are easy to use, they are recommended for use in domestic applications such as the distribution of water in combination with small or medium sized pressure tanks, and for the irrigation of gardens and orchards, etc. Installation needs to be undertaken in well ventilated closed areas or anyway protected from bad weather. PATENTS - TRADE MARKS - MODELS JSW® Registered Trade Mark n. 013073135 Registered EU Design n. 002218610 European Patent n. 1 510 696 OPTIONS AVAILABLE ON REQUEST Pump body with NPT ANSI B 1.20.1 threaded ports Pumps with technopolymer impeller Other voltages GUARANTEE 2 years subject to terms and conditions PERFORMANCE RANGE Flow rate up to 60 l/min (3.6 m³/h) Head up to 48 m APPLICATION LIMITS Manometric suction lift up to 9 m (HS) Liquid temperature between -10 °C and +40 °C Ambient temperature up to +40 °C Max. working pressure 6 bar Continuous service S1 CONSTRUCTION AND SAFETY STANDARDS EN 60335-1 IEC 60335-1 CEI 61-150 EN 60034-1 IEC 60034-1 CEI 2-3 CERTIFICATIONS Company with management system certified DNV ISO 9001: QUALITY Clean water Domestic use Self-priming “JET” pumps 60 Hz | JSW1
4

JSW1 - Pedrollo · 2020. 9. 3. · JSW1. JSW1. 124 | GENERAL CATALOGUE 60 Hz. INSTALLATION AND USE. Suitable for use with clean water and with liquids that are not chemically aggressive

Mar 28, 2021

Download

Documents

dariahiddleston
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: JSW1 - Pedrollo · 2020. 9. 3. · JSW1. JSW1. 124 | GENERAL CATALOGUE 60 Hz. INSTALLATION AND USE. Suitable for use with clean water and with liquids that are not chemically aggressive

JSW1

124 | GENERAL CATALOGUE 60 Hz

INSTALLATION AND USESuitable for use with clean water and with liquids that are not chemically aggressive towards the materials from which the pump is made. The self-priming JSW pumps are designed to pump water even in cases where air is present. Because of their reliability and the fact that they are easy to use, they are recommended for use in domestic applications such as the distribution of water in combination with small or medium sized pressure tanks, and for the irrigation of gardens and orchards, etc.Installation needs to be undertaken in well ventilated closed areas or anyway protected from bad weather.

PATENTS - TRADE MARKS - MODELS • JSW® Registered Trade Mark n. 013073135 • Registered EU Design n. 002218610 • European Patent n. 1 510 696

OPTIONS AVAILABLE ON REQUEST • Pump body with NPT ANSI B 1.20.1 threaded ports • Pumps with technopolymer impeller • Other voltages

GUARANTEE2 years subject to terms and conditions

PERFORMANCE RANGE • Flow rate up to 60 l/min (3.6 m³/h) • Head up to 48 m

APPLICATION LIMITS • Manometric suction lift up to 9 m (HS) • Liquid temperature between -10 °C and +40 °C • Ambient temperature up to +40 °C • Max. working pressure 6 bar • Continuous service S1

CONSTRUCTION AND SAFETY STANDARDSEN 60335-1IEC 60335-1CEI 61-150

EN 60034-1IEC 60034-1CEI 2-3

CERTIFICATIONSCompany with management system certified DNVISO 9001: QUALITY

Clean water

Domestic use

Self-priming “JET” pumps

60 Hz | JSW1

Page 2: JSW1 - Pedrollo · 2020. 9. 3. · JSW1. JSW1. 124 | GENERAL CATALOGUE 60 Hz. INSTALLATION AND USE. Suitable for use with clean water and with liquids that are not chemically aggressive

0 5 10 15 20 25 30 35 40 45 50 55 605

10

15

20

25

30

35

40

45

50

25

50

75

100

125

150

0 5 10 15

0 5 10

0 0.5 1 1.5 2 2.5 3 3.5

HS = 9 m

9 m

8

7

6

5

43

21

1

1

2

2

3

3

4

4

5

5

6

6

7

7

8

8

HS = 9 m

US g.p.m.

Imp g.p.m.feet

l/minm³/h

JSW1A

JSW1B

JSW1C

JSW1

2

0 bar

4 6

8

10

2

0 bar

4 6

8

10

GENERAL CATALOGUE 60 Hz | 125

CHARACTERISTIC CURVES AND PERFORMANCE DATA 60 Hz n= 3450 min-1 HS= 0 m

Flow rate Q 4

Hea

d H

(met

res) 4

STANDARD INSTALLATION

MODEL POWER (P2)Q

m³/h 0 0.3 0.6 1.2 1.5 1.8 2.4 2.7 3.0 3.6

Single-phase Three-phase kW HP � l/min 0 5 10 20 25 30 40 45 50 60

JSWm 1 C JSW 1 C 0.37 0.50IE2

H metres

35 32 28.5 23.5 21 18.5 15 13.5 12 10

JSWm 1 B JSW 1 B 0.48 0.65 37 34 30.5 25.5 23 20.5 17 15.5 14 12

JSWm 1 A JSW 1 A 0.55 0.75 IE3 48 43 39 31.5 28.5 26 22 20.5 19 17

Q = Flow rate H = Total manometric head HS = Suction height Tolerance of characteristic curves in compliance with EN ISO 9906 Grade 3B.

� Three-phase motor efficiency class (IEC 60034-30-1)

JSW1 | 60 Hz

Page 3: JSW1 - Pedrollo · 2020. 9. 3. · JSW1. JSW1. 124 | GENERAL CATALOGUE 60 Hz. INSTALLATION AND USE. Suitable for use with clean water and with liquids that are not chemically aggressive

JSW1

1 43 6 95

772 8

126 | GENERAL CATALOGUE 60 Hz

POS. COMPONENT CONSTRUCTION CHARACTERISTICS

1 PUMP BODY Cast iron with an Epoxy Electro Coating treatment, with threaded ports in compliance with ISO 228/1

2 BODY BACKPLATE Stainless steel AISI 304

3 NOZZLE ASSEMBLY Noryl

4 IMPELLER Stainless steel AISI 304

5 MOTOR SHAFT Stainless steel AISI 431

6 MECHANICAL SEAL Seal Shaft MaterialsModel Diameter Stationary ring Rotational ring Elastomer

AR-12 Ø 12 mm Ceramic Graphite NBR

7 BEARINGS 6201 ZZ / 6201 ZZ

8 CAPACITOR Pump CapacitanceSingle-phase (220 V) (110 V or 127 V)

JSWm 1C 10 μF - 450 VL 25 μF - 250 VLJSWm 1B 10 μF - 450 VL 25 μF - 250 VLJSWm 1A 14 μF - 450 VL 25 μF - 250 VL

9 ELECTRIC MOTOR JSWm: single-phase 220 V - 60 Hz with thermal overload protector incorporated into the winding.JSW: three-phase 220/380 V - 60 Hz or 220/440 V - 60 Hz.

➠ The three-phase pumps are fitted with high performance motors up to P2=0.48 kW in class IE2 and from P2=0.55 kW in class IE3 (IEC 60034-30-1)

– Insulation: class F – Protection: IP X4

60 Hz | JSW1

Page 4: JSW1 - Pedrollo · 2020. 9. 3. · JSW1. JSW1. 124 | GENERAL CATALOGUE 60 Hz. INSTALLATION AND USE. Suitable for use with clean water and with liquids that are not chemically aggressive

f

a

w

DN

1

h1

h3

h2

t

n2

h

s

DN2

GENERAL CATALOGUE 60 Hz | 127

DIMENSIONS AND WEIGHT

MODEL GROUPAGE CONTAINER

Single-phase Three-phase n. pumps n. pumps

JSWm 1C JSW 1C 98 140

JSWm 1B JSW 1B 98 140

JSWm 1A JSW 1A 98 140

MODEL VOLTAGE

Three-phase 220 V 380 V 220 V 440 V

JSW 1C 2.0 A 1.15 A 1.7 A 1.1 A

JSW 1B 2.3 A 1.3 A 2.1 A 1.2 A

JSW 1A 3.1 A 1.8 A 2.6 A 1.5 A

MODEL VOLTAGE

Single-phase 220 V 110 V 127 V

JSWm 1C 3.0 A 6.0 A 5.2 A

JSWm 1B 3.3 A 6.6 A 5.7 A

JSWm 1A 4.0 A 8.0 A 6.9 A

MODEL PORTS DIMENSIONS mm kg

Single-phase Three-phase DN1 DN2 a f h h1 h2 h3 t n2 w s 1~ 3~

JSWm 1C JSW 1C

1" 1" 94 357 171 127 35 162 158 124 24 10

9.8 9.7

JSWm 1B JSW 1B 9.7 9.9

JSWm 1A JSW 1A 10.5 9.7

ABSORPTION

PALLETIZATION

JSW1 | 60 Hz