oil, gas, heat pumps, wood, pellet, solar & wind.
High-efficiency Polyurethane insulation and powder paintedsteel
casing provide high thermal efficiency and modernappearance.
Oval thermal tanks are only 780 mm wide so they fit through
Jaspi Thermal Storage Tanks use the best-in-class heatstorage
and discharge technology. Design and location ofthe connections
ensure efficient thermal layering and easyinstallation.
Classy and efficient, the GTV tanks are suitable for
newapplications as well as heating system renovations for
Jaspi GTV thermal tanks feature thick, high
efficiencypolyurethane insulation minimizing the ambientheat
loss.
All Jaspi GTV thermal tanks have a powder painted steelcasing,
are designed to fit through narrow openings andcan be positioned in
confined spaces.
Indirect hot water coils are flange mounted and can easily
expanding water space and storing energy, for example inheat
pump systems.
be installed later on or replaced if needed. All GTV
thermaltanks have connections for electric immersion heaters.
Jaspi GTV thermal storage tanks Jaspi Oval thermal storage
tanks
Jaspi Oval thermal tanks can be used with any heat source;
most doors and take less space than an equivalent roundcylinder.
This makes them especially suitable for heatingsystem upgrades and
renovations.
thermal storageJASPI GTV & Oval
-
Jaspi GTV 500Jaspi GTV 500 is used as a heat storage for
largerenergy quantities. Connected in series, GTV 500 thermaltanks
are a good solution for more powerful solid fuelheating or
night-time electric charge. A hot water coilwill be selected for
GTV 500 based on hot water supplydemand.
GTV 500 to boiler connection1. Heat source, solid wood boiler,
heat pump etc.2. GTV 500 thermal storage tank3. Thermostatic mixing
hot water supply valve4. Heating circuit circulating pump5.
Charging pump6. Expansion vessel7. Required quantity of electric
immersion heaters8. Boiler filling valve9. Thermal safety valve10.
1.5 bar safety valve11. Thermostatic charging valve12. Pump
thermostat
ModelGTV500-1,5500-35-1,5500-80-1,5500-4500-35-4500-80-4500-100-4
700
700-35
Volumel
500500500500500500500
700700
Weightkg210210210210210210210
230230
Pressurebar1,51,51,54,04,04,04,0
1,51,5
l/min-
3580-
3580100
-35
-Ø22 Cu
R 1”-
Ø22 CuR 1”
R 1 1/4”
-Ø22 Cu
Dimensions mmheight (A) x width (B) x depth (C)
1665 x 743 x 7431665 x 743 x 7431665 x 743 x 7431665 x 743 x
7431665 x 743 x 7431665 x 743 x 7431665 x 743 x 743
2000 x 780 x 8202000 x 780 x 820
Hot water coil
Specifications Jaspi GTV 5001. Replaceable hot water coil2. R 2"
electric immersion heater3. R 1" heating circuit flow4. R 1” boiler
supply5. Additional R 1" heating circuit flow / return6. R 1"
boiler return / heating circuit return7. R 1/2” drain
Specifications Jaspi GTV 7001. Ø22 Cu solar power coil
(optional)2. R 2" BP electric immersion heater3. Ø22 hot water and
additional heat source coils4. R 1/2" lower level thermometer5. R
1/2" upper level thermometer6. R 1” BP heating circuit
outlet/expansion (ensure deaeration)7. R 3/4” BP drain8. R 1” BP
heating circuit return (expansion)9. R 1" BP underfloor heating
circuit return10. R 3/4” BP thermostat11. R 1” BP underfloor
heating supply. Can also be used as
an additional heating circuit feed12. R 1” BP direct boiler
connection
Jaspi GTV 700Jaspi GTV 700 is designed to be connected to
various, simultaneousenergy sources. It can be used as a heat store
for heat pumps,solid fuel, pellet, oil & gas boilers. Also
Solar and wind power systemscan be connected. GTV 700's two
domestic hot water coils ensureconstant high pressure hot water
supply. GTV 700 can accommodateup to 3 separate heat sources. The
solar indirect coil can also beadded at a later stage.
Design temperature: 100 °CWe reserve the right to modify design
and dimensions
All measurements in mm.
-
Jaspi Oval thermal storage tanks 1000, 1200, 1500, 1800,
2400
Jaspi Thermal Storage Tanks use the best-in-class heat storage
and discharge technology. Design and location of theconnections
ensure efficient thermal layering and easy installation.
Domestic hot water is supplied via the internal high efficiency
hot water coil(s) which can easily be replaced or upgraded.As the
high efficiency hot water coil(s) produce the hot water when it is
needed, there is no need for a separate water heater.
flexibility to use the cheapest heat source available at the
time. Jaspi Oval thermal tanks can be used with any heat
source;oil, gas, heat pumps, wood, pellet, solar & wind.
Several heating circuits can be supplied from a single tank,
making it easy to separate between radiators / underfloor heatingor
main house / garage or annex.
Optional night storage electric immersion heaters are located at
the lowest possible height to heat the entire water volume
Specifications1. R 1 1/4" supply from the boiler2. R 2" return
to the boiler/expansion3. R 2" night time electric immersion
heater4. R 2" daytime electric immersion heater5. R 1" heating
circuit flow6. R 1" heating circuit return7. Ø22 hot water
preheating coil8. Ø22 hot water main coil9. Ø22 solar coil
(optional)10. R 3/4" nightime thermostat connection11. R 3/4"
daytime thermostat connection12. R 1/2" thermometer connection13. R
1/2" drain connection14. R 1" air vent/expansion vessel
connection
Model
Oval
1.0
1.2
1.5
1.8
2.4
Volume
(l)
1000
1200
1500
1800
2400
Weight
(kg)
270
305
365
410
525
Dimensions mmheight (A) x width (B) x depth (C)
1720 x 1230 x 780
2020 x 1230 x 780
1720 x 1770 x 780
2020 x 1770 x 780
2020 x 2310 x 780
Design pressure: 1.5 barDesign temperature: 100°CWe reserve the
right to modify design and dimensions
All measurements in mm.
Oval 2.4Oval 1.0 / 1.2 Oval 1.5 / 1.8
Oval thermal tanks are only 780 mm wide so they fit through most
doors and take less space than an equivalent roundcylinder. This
makes them perfect for heating system renovations.
The solar indirect coil can also be installed at a later
stage.
with cheaper night tariff. Another set higher up the tank can be
used during the day and warms the top of the tank only.
15. Detachable lifting hook
Jaspi Oval provides unrivalled expandibility. Up to six heat
sources can be connected in to a single tank giving the user
-
Oval thermal storage tank connected to a solid fuel boiler
Oval thermal storage tank connected to solar heating system
Oval thermal storage tank connected to an air-to-water heat
pump
System connection examples. Do not use as detailed installation
drawings.
-
water output even in the most demanding circumstances.
demand.
Jaspi-Immersion heaters
back-up and boost in the event of a boiler failure, orwhen other
heat sources are not available. All threeversions; 3, 4.5 & 6kW
have a built-in thermostat,safety cut-off, indicator light and are
made of high
Solar heating package
This Solar heating package can be connected to any
solar panels, pump station, solar controller, 40 L of
transfer
immersion coil is needed.
JAMA Moon 10 Air-to-water heat pump
Extra equipment for Jaspi Thermal Storage Tanks
ISO 14001ISO 9001EN 729-2
HEAT ING
Copper coilAn efficient Cu-coil guarantees excellent domestic
hot
With special order heat storage tanks are deliveredwith even
higher output coils, based on DHW supply
Perfect fit for GTV & Oval tanks. They will provide
grade, ultra long life Incoloy Alloy Steel.
Jaspi GTV or Oval system. Full kit includes 3 or 5
fluid, roof fixings and an expansion vessel. In addition to a
solar heating kit, a pre-heating coil as well as a solar
Manufacturer:
KAUKORA OY
Email [email protected] www.jaspi.uk
Telephone 01392 247 343JASPI UK
/ColorImageDict > /JPEG2000ColorACSImageDict >
/JPEG2000ColorImageDict > /AntiAliasGrayImages false
/CropGrayImages true /GrayImageMinResolution 150
/GrayImageMinResolutionPolicy /OK /DownsampleGrayImages true
/GrayImageDownsampleType /Bicubic /GrayImageResolution 200
/GrayImageDepth -1 /GrayImageMinDownsampleDepth 2
/GrayImageDownsampleThreshold 1.12500 /EncodeGrayImages true
/GrayImageFilter /DCTEncode /AutoFilterGrayImages true
/GrayImageAutoFilterStrategy /JPEG /GrayACSImageDict >
/GrayImageDict > /JPEG2000GrayACSImageDict >
/JPEG2000GrayImageDict > /AntiAliasMonoImages false
/CropMonoImages true /MonoImageMinResolution 1200
/MonoImageMinResolutionPolicy /OK /DownsampleMonoImages true
/MonoImageDownsampleType /Bicubic /MonoImageResolution 1200
/MonoImageDepth -1 /MonoImageDownsampleThreshold 1.50000
/EncodeMonoImages true /MonoImageFilter /CCITTFaxEncode
/MonoImageDict > /AllowPSXObjects false /CheckCompliance [ /None
] /PDFX1aCheck false /PDFX3Check false /PDFXCompliantPDFOnly false
/PDFXNoTrimBoxError true /PDFXTrimBoxToMediaBoxOffset [ 0.00000
0.00000 0.00000 0.00000 ] /PDFXSetBleedBoxToMediaBox true
/PDFXBleedBoxToTrimBoxOffset [ 0.00000 0.00000 0.00000 0.00000 ]
/PDFXOutputIntentProfile () /PDFXOutputConditionIdentifier ()
/PDFXOutputCondition () /PDFXRegistryName () /PDFXTrapped
/False
/Description >>> setdistillerparams>
setpagedevice