Top Banner
JA-80 JA-80 Make your premises an Oasis of security JA-80_EN_042007_c1
73

JA-80

Feb 02, 2016

Download

Documents

yves

JA-80. Make your premises an Oasis of security. JA-80_EN_042007 _c1. A solution for your security & comfort. Oasis basic features:. 50 addresses for wireless devices (detectors, RC, keypads and sirens) 50 positions for user codes or/and proxy cards - PowerPoint PPT Presentation
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: JA-80

JA-80JA-80Make your premises an Oasis of security

JA-80_EN_042007_c1

Page 2: JA-80

A solution for your security & comfort......

Page 3: JA-80

Oasis basic features:

50 addresses for wireless devices (detectors, RC, keypads and sirens)

50 positions for user codes or/and proxy cards

2 wired inputs in the control panel ( plus Inputs in keypad and detectors)

Lithium batteries – calculated lifetime 3 years

868 MHz operating frequency

Grade 2 by the EN 50131 standard (medium risk)

Page 4: JA-80

“LEGO” architecture

Page 5: JA-80

JK-81JK-81 kit kit

Devices supplied pre-enrolled and pre-programmed

Simple installation

Page 6: JA-80

JK-81JK-81 consists of: consists of: Control panel with GSM communicator Wireless keypad PIR detector Magnetic detector Indoor siren Key fob Wireless door bell button Proximity card Accessories (batteries etc.)

Page 7: JA-80

11

55 66

77

Installation in 7 steps Installation in 7 steps

33

44

22

Page 8: JA-80

Service mode after powering upService mode after powering up

AA:: Enrollment ofEnrollment of more devicesmore devices

• key key 11 and connect batteriesand connect batteries, , exitexit with with ##

BB: Communication quality test: Communication quality test

• keykey 298298 ( (turns on signal measurementturns on signal measurement))

• arrow keys scroll devicesarrow keys scroll devices

• device triggering = signal from 1/4 to 4/4device triggering = signal from 1/4 to 4/4

• # returns you to Service mode # returns you to Service mode

•CC:: GSM signal strength testGSM signal strength test

• keykey 992222

• return to Service mode by #return to Service mode by #

Each signal should be at leastEach signal should be at least 2/4 2/4

Page 9: JA-80

ProgrammingProgrammingExample:Example:

4 hh mm DD MM YY4 hh mm DD MM YY = = clockclock

220011 Exit delayExit delay 10sec. 10sec.

81 1 777 775 081 1 777 775 02222 00 = tel. = tel. numbernumber

92619261 = = forward forward SMSSMS

Page 10: JA-80

299299 enrollment of PGX to AC relay X enrollment of PGX to AC relay X232377 PGX function = on / off PGX function = on / off

Page 11: JA-80

Handover to the userHandover to the user

Page 12: JA-80

SET(arm)

UNSET(disarm)

Operating a key-fobOperating a key-fob

Both buttons Both buttons = = PANICPANIC

Page 13: JA-80

Keypad layoutKeypad layoutAlarm or fault SET A, B and C Power

DetailsSetting (arming)Hot keysA, B & C

PGXOn / Off

Detail reading

Page 14: JA-80

Let the user feel that (s)he is the masterLet the user feel that (s)he is the master

„Master“ card enrollment: 5 1234 card

Access card enrollment: 6, Master card, key nn, card

Access code programming: 6, Master card, key nn, code

To erase access code and card: 6, Master card, key nn, 0000

nn = user number 01 to 50Each user can have code, card or both

John 2375

Page 15: JA-80

Keypad operation Keypad operation Card / code Unsetting / Setting

ABC Complete setting

A Partial setting A (if used)

B Partial setting B (if used)

? Status details (open windows, PG, faults)

PGX on

PGX off

# Esc

Function

Page 16: JA-80

instructionsinstructions 1 ABC arming(=ABC button)

2 A arming(=A button)

3 B arming(=B button)

4 Memory reading

5 Master code / card changing

6 Access code / card programming

7 Operating under duress

8 PGX control (81/80 = on/off or 8 = 2sec. pulse)

9 PGY control (91/90 = on/off or 9 = 2sec. pulse)

0 Service or Maintenance ( 0 service or master code)

Page 17: JA-80

2 level partial arming

Evening armingGarage….

A

C

BA

KeyKey AAAA A

A

A

B

B

B

C

C

C

KeyKey B BA+BA+B

Key Key ABCABCA+B+CA+B+C

Night armingGround floor + garage

Complete arming

Example: Family house

Page 18: JA-80

Split systemExample: Two families in a house

Code or cardBush

If both A+B armed,then C also armed

A

C

B

A B

A B

BushARMED

BlairARMED

Entire house armed incl. Common section

Code or cardBlair

C

C

Page 19: JA-80

Communicator testCommunicator testBoth buttonsBoth buttonsPANIPANICC

Panic alarm SMS

Result:

Function test Knowing the SIM card tel. number

Page 20: JA-80

Remote access testingRemote access testingPhone keypad authorization: Call and wait for the system to respond (after 5 rings) Enter a valid code (master, user or service) Operate the system… hang up at the end

SMS instructions: „Code space INSTRUCTION“

SET Arming

UNSET Disarming

STATUS Status checking

MEMORY Last event memory checking

PGX ON Turning PGX on

PGX OFF Turning PGX off

PGY ON Turning PGY on

PGY OFF Turning PGX off

AUX ON Turning AUX on

AUX OFF Turning AUX off

CREDIT Prepaid SIM card balance checking

Page 21: JA-80

Control panel JA-80KFeatures 1: Back up battery 1.3Ah or 2.6Ah Standby consumption 50 mA Outputs:

EW - external warning (dry contact, max. 1A) IW - internal warning (switches to GND, max. 0.5A) PGX & PGY (switch to GND max. 0.2A) +U power, max. 0.4A

Built in transceiver Optional external antenna Up to 50 wireless devices

Selectable reactions (Natural or others) Assignment to sections (A, B, C) All devices have natural reaction in section C as factory-default Devices can also be enrolled by keying in their production codes

Page 22: JA-80

Control panel JA-80KHard-wired inputs (addresses 01 and 02)Maximum of 5 detectors in a loop, Differentiates between triggering and tamperingProgrammable reaction (Natural = delayed)Enrollment of a wireless device to address 01 or 02 disables the input terminal

Connected to COM via a 1 k resistor = untriggered input Connected to COM via 2 to 5 k = triggered input, Connected to COM via less then 700 or more then 7k8 k = tamper signal

Page 23: JA-80

Features 2: Two-level partial setting (A, AB, ABC) Or split system: A, B and C (common section) Devices and codes/cards can have reactions:

Off, Natural, Panic, Fire, 24hr., Next delay, Instant, Set, PG control, Set/Unset Up to 5 final-door detectors Intruder alarm confirmation by a 2nd detector Annual inspection request indication option Indication of permanently triggered detectors (details by ? key) Winter/Summer time automatic change (1st of November/1st of April) Memory for the last 255 events Replaceable memory chip

Can be operated with up to: 50 user codes (locally or remotely by phone or internet) 50 user cards Option: Confirmation of the card by code

Control panel JA-80K

Page 24: JA-80

The JA-80F keypad

LCD (2x 16 characters) 1st line = status or event 2nd line = name of the event source

Keypad menu – 15 languages and Chime feature Built in proximity card readers Hard-wired input IN (NC,

Natural reaction = Delayed) Arrow keys allow you to control PGX (81 and 80)

A, B & ABC arming hot keys

? Detail reading

Keypad turns off after 20sec (if battery powered) 2 x AA Lithium 3V batteries (3 year lifetime - 2 operations/day)

JA-80E = hard-wired version

Page 25: JA-80

Keypad text editingIn service mode: Holding ? pressed opens editing Keys:

Arrow – selects the text string to be edited 1 and 7 - scroll through characters (A, B, C…..8,9,0)4 and 5 - move cursor 2 deletes character# exits editing

Comlink SW allows more convenient editing (special signs / letters enabled) - keypad must be connected to the control panel bus

Page 26: JA-80

The PC-01 proximity card RFID access card (EM UNIQUE 125kHz)

Up to 50 cards can be enrolled to the system The card has the same function as an access code For higher security the card can be combined with a code PC-02 is a key tag version

Page 27: JA-80

The JA-80H outdoor keypad Built in RFID reader Connects to the control panel bus via WJ-80 Provides a doorbell button Illuminated keys IP-65 Standby consumption 45 mA

Page 28: JA-80

The JA-80N outdoor reader RFID card reader Connects to the control panel bus via WJ-80 IP-65 Standby consumption 40 mA

Page 29: JA-80

The WJ-80 interface Connects outdoor keypad (reader) to the control panel Built-in door bell transmitter (for JA-80L) Output to operate an electrical door lock (Z8-12V) Provides output to operate the electric strike of an

electrical door lock an open button input Keypad uses Wiegand protocol 26b DIP switches:

1. System keypad / Outdoor bypass switch2. PGY can operate the door lock as well (Y/N)3. Door lock activation time 3 / 6 seconds4. Exit & entrance beeps (Y/N)

Control panel bus

Sequence248 = PGY pulseAuthorized phone opening777 775 0229To program81 1 777 775 022 *79*0

Page 30: JA-80

The RC-80 key-fob 2 housings provided (2 or 4 buttons) Key lock (4 buttons only) Can also be used with UC, AC, JA-80L an CA-180x Alkaline battery 6V, life time 2 to 3 years Working range up to 100m

Page 31: JA-80

The RC-88 button

DIP switches: Panic (remote control or panic button function) TMP (disable tamper sensors and communication supervision)

Can also be used with UC, AC and JA-80L 1x 1/2 AA Lithium 3V battery

(3 year life time, max. 20 activations/day)

Page 32: JA-80

The RC-89 door bell button Works with the JA-80L indoor siren Can be enrolled to the control panel as a portable panic

button (by keeping pressed for 3 seconds) Can also be used with AC and UC modules No radio communication supervision 6V alkaline battery Working range up to 200m

Mr. Jones

Page 33: JA-80

The RC-87 personal panic button Can be enrolled to the control panel, siren or UC/AC modules Optional

Wrist watch or necklace version Audible confirmation of triggering Delay (10s) to stop accidental triggering

No radio communication supervision CR2032 lithium battery Working range up to 200m

HW in testing

Page 34: JA-80

The RC-85 remote control module Designed to be installed in a car (from 12V to 24V) 3 wires

GND A = if connected to +U transmits signal B = if connected to +U transmits signal both A + B connected to +U transmits a panic signal

Works with the control panel, UC, AC and JA-80L No battery, powered by car Flashing full-beam headlights or blowing the horn send signals Can also be used to transmit an alarm from a car alarm Optional to choose “double click” activation

Page 35: JA-80

The JA-80P detector PIR sensor Hard-wired input IN (initiate same reaction as PIR) 15 min test mode after closing the cover 5 min sleep time (can be shortened to 1 minute) DIP switches

DEL / INS (natural reaction) NORM / HIGH (immunity level)

Covers 120° / 12m Optional lenses (pet, long corridor, vertical curtain)

1 x AA Lithium battery 3V (3 year life time)

úhel záběru(poh led shora)

2

2,5

1,5

1

0,5

1,6 3,7 12 dosah[m]

výška[m]

Pracovní dosah - pohled z boku

120º

12m

zóna A

zóna B

zóna C

zóna A

zóna Bzóna C

Page 36: JA-80

The JA-80PB detector PIR sensor + glass-break sensor Enrolls to 2 addresses in the system PIR = identical to JA-80P GB detection - up to 9m (GBT-212 tester) 15 min test mode after cover closing Glass-break DIP switches

DEL / INS (natural reaction) PIR / GBS (LED indicator function in test mode)

2 Lithium 3V batteries: 1 x AA + 1x 1/2 AA

úhel záběru(poh led shora)

2

2,5

1,5

1

0,5

1,6 3,7 12 dosah[m]

výška[m]

Pracovní dosah - pohled z boku

120º

12m

zóna A

zóna B

zóna C

zóna A

zóna Bzóna C

Page 37: JA-80

PIR sensor + CMOS camera PIR = identical to JA-80P 2 way communication Processing module in the control panel If armed and a movement detected = takes pictures

1st immediately without flash 2nd & 3rd with flash High resolution stored to internal memory (USB) Low resolution sent to server (within 25sec)

2 Lithium 3V batteries AA sizeúhel záběru

(poh led shora)

2

2,5

1,5

1

0,5

1,6 3,7 12 dosah[m]

výška[m]

Pracovní dosah - pohled z boku

120º

12m

zóna A

zóna B

zóna C

zóna A

zóna Bzóna C

Working samples

The JA-84P detector & camera

Page 38: JA-80

The JA-89P detector Outdoor PIR sensor 2 sensors eliminate small animals Adjustable detection angle IP-54 cover Installation height 0.8 - 1.2 m 1 x AA Lithium battery 3V (3 year life time) Based on the Optex product

Working samples

Covered area adjustable not covered area

Page 39: JA-80

The JA-80M detector Magnetic door / window detector Status detector (optional pulse reaction) DIP switches:

DEL / INS (natural reaction) MG ON / MG OFF (enables/disables internal sensor)

2 input terminals: TMP = tamper input IN = alarm input

1x 1/2 AA Lithium 3V battery (3 year life time for 20 activations/day)

m a x. 5 m mm

agne

t

LIT

HIU

M3V

1/2

AA

+

M G O FF

M G O N

tam per sw itch

externalsensor

Reaction

m ag. sensor O N/O FF

INSTAN T

DELAYED

Page 40: JA-80

The JA-82M detector Invisible window (door) detector (EURO or wooden) To be installed in the frame of a window (door) DIP switches:

INS / DEL TMP on / off Status / pulse reporting

Communicating range up to 200 meters 2 x CR2354 Lithium 3V battery

(3 year life time 5 activations/day)

A

B

Prototypes

Page 41: JA-80

The JA-80S detector

LITHIUM 3V AA+

Int. S iren

O n

O ff

Reaction

Fire

Instant

Fire detector (optical smoke + temperature over 60°) Testing by test button or by aerosol Optional to disconnect siren by test button in alarm Jumpers:

FIRE / INS (natural reaction) SIREN ON / OFF (enables / disables internal siren)

1x AA Lithium 3V battery (3 year life time)

Page 42: JA-80

The JA-80G detector Combustive gas or fume detector Mains powered Can be tested with a cigarette lighter DIP switches:

10 / 20% LEL (gas concentration) MEM ON / OFF (memory function)

Output relay contact max. 6A

Prototypes

Page 43: JA-80

The JA-85P detector Mini-size PIR detector Can be used in a house or in a car (CA-1802 or 1803) 15 min test mode after closing the cover DIP switches

NORM / HIGH (immunity level) DEL / INS (natural reaction) Supervision ON / OFF Sleep 1 / 5 minutes

Semi-sphere lens max. detection distance 5m Communicating range up to 200 meters 1 x AA Lithium 3V battery

(3 year life time)

Page 44: JA-80

The JA-85B detector Mini-size glass-break detector Can be used in a house or in a car (CA-1802 or 1803) 15 min test mode after closing the cover DIP switches

DEL / INS (natural reaction) Supervision ON / OFF

Detection up to 9 meters (can be tested with GBT-212) Communicating range up to 200 meters 1 x AA Lithium 3V battery

(3 year life time)

Page 45: JA-80

The JA-80L indoor siren Mains powered

Tampering reported if disconnected from the power during an alarm = ALARM CONFIRMATION

Enrolls by plugging in Generates sounds:

IW alarm Exit and entrance beeps Door bell - 8 melodies Detector - triggered sounds - 8 melodies

LED indicates PGY status Two volume levels (by keeping the button pressed) Triple click enables/disables arming chirp sounds Signal level measurement – by pressing button

Page 46: JA-80

The JA-80A outdoor siren Totally wire-free !!! Loudness increases gradually Max. duration of the siren sound: 3 min. Flashes 30 min. after the alarm Jumpers:

50 / 25 s. (communication cycle with the control panel) LED ON / OFF (warning flash every minute)

Enrolls by connecting its battery Lithium battery BAT-80 (max. life time 3 to 5 years)

S ire n c o nn e c to r(b e w a re o f h ig h v o lta g e s )

L E D s

To p c ov e r s e ns o r S ire n re m ov a l s en s o r

B a tte ry co n n e c to r

enabled

disabled

communication

interval 25s

interval 50s

LED indication

a n te n n a

Page 47: JA-80

The JA-80Y communicator Communication via GSM/GPRS GSM gateway function Events reporting by:

SMS (15 lang. Selection) phone calls ARC (IP, SMS or CID protocols), ARC

programming can be locked Remote access via:

Phone (keypad registration or SMS) Internet - www.gsmlink.cz Unanswered ringing from an authorized phone

number ARC programming can be locked Remote access possible with a valid code

(UC, MC, SC)

Page 48: JA-80

Combination of LAN and PSTN enables the same features as GSM / GPRS.

Most of the JA-80V and JA-80Y functions are identical

The JA-80V communicator Communication via LAN & PSTN Events reporting by:

SMS (15 lang. selection) phone calls ARC (IP, CID or DR protocols) ,ARC

programming can be locked Remote access via:

Phone (keypad registration or SMS) Internet - www.gsmlink.cz Unanswered ringing from an authorized phone

number Remote access possible with a valid code

(UC, MC, SC)

Page 49: JA-80

INTERNETINTERNET

Events reportingEvents reporting

OasisOasis

Telephone networkTelephone network

AutomaticAutomaticReceivingReceivingCenter Center

andandoror

UserUsernotificationnotification

Page 50: JA-80

Remote accessRemote accesswww.GSMLink.czwww.GSMLink.cz

INTERNETINTERNET

InternetInternet TTelephoneelephone

aandndoror

Page 51: JA-80

The JA-80X voice communicator Reports alarms with voice messages Up to 4 phone numbers via PSTN 7 voice messages

System name Intrusion Fire Tampering Panic Technical alarm Remote access welcome note

Allows remote access via telephone keypad authorization (DTMF)

Supports CID protocol transmission to ARC (PSTN line) Can be combined with JA-80V or JA-80Y

Prototype

Page 52: JA-80

The SP-02 speaker phone For listening in and talking Can be connected to PSTN or to the phone line

simulated by JA-80Y Answers calls from authorized numbers Half-duplex communication allows a high sensitivity

for listening Push-to-talk feature to call an emergency number 2 x AA alkaline 1.5V battery

Prototype

Page 53: JA-80

The UC-82 relay module Powered by 12V DC 2 output relays (X & Y) - max 2A Low bat. output External antenna is optional Powered by 12V (20mA) external source Can be used with:

Control panel Detectors RC-8x transmitters

no. Reaction Device Enrolls with Max. number

key fob button pressing 1 impulse 1 sec. detector battery connecting

60

key fob button pressing 2 impulse 2 min. detector battery connecting

60

latch key fob button pressing 60 3 tamper detector battery connecting 8

key fob button pressing 60 on / off PG outputs of

control panel entry of 299 in Service mode

1 4

triggering detector battery connecting 8

buttons

P C B tab

Y

Y

X

X

tam persw itch

ext.an tenna connector

RA

DIO

1234

LED s

Page 54: JA-80

The AC-82 relay module Powered directly from mains 230V, 50Hz 2 output relays (X and Y) - max 5A Can be used with:

Control panel Detectors RC-8x transmitters TP-8x thermostats

no. Reaction Device Enrolls with Max. number

key fob button pressing 1 impulse 1 sec. detector battery connecting

60

key fob button pressing 2 impulse 2 min. detector battery connecting

60

latch key fob button pressing 60 3 tamper detector battery connecting 8

key fob button pressing enrolls pair of buttons

60

PG outputs of control panel

entry of 299 in Service mode

1 on / off

thermostat battery connecting 8

4

triggering detector battery connecting 8

1234

RA

DIO

ma

x F

5 A

/ 25

0V

buttons

LEDs

fusem ax 5 A

X Y

Page 55: JA-80

The TP-80 thermostat Enrolls to AC-82 Transmits signals:

Temperature below target (normal heating) Below 6°C (anti-freezing) Below 3°C (Freezing alarm - Panic) Above 60°C (Fire alarm) Supervision and battery status

Normal heating can be enabled or disabled in the AC-82 receiver by signals from the control panel (PG), remote controls or detectors

1 AA alkaline battery 1.5V, 1 year lifetime

Page 56: JA-80

The TP-82 thermostat Enrolls to AC-82 Indicates temperature Transmits signals:

Temperature below target (normal heating) Below 6°C (anti-freezing) Below 3°C (Freezing alarm - panic) Above 60°C (Fire alarm) Supervision and battery status

Normal heating can be enabled or disabled in the AC-82 receiver by signals from the control panel (PG), remote controls or detectors

1 AA alkaline battery 1.5V, 1 year life timeTP-83 weekly temperature programming ( 3Q 2007)

Page 57: JA-80

Simple heating control

Thermostat AC-82

Radio Cable

Thermostat is enrolled to the AC receiver

Page 58: JA-80

Heating

AC-82

Thermostat

Window detectors Control panelRemote controls

Telephone

Smart heating systemSmart heating system

Thermostat is enrolled to the AC receiver and also to the control panel

Page 59: JA-80

Normal heating controlHeating = ON

Heating

AC-82

Thermostat

Window detectors Control panelRemote controls

Telephone

Smart heating systemSmart heating system

Page 60: JA-80

Heating

AC-82

Thermostat

Window detectors Control panelRemote controls

Telephone

Smart heating systemSmart heating system

Operating heating by remote controlsON = normal heatingOFF = anti-freezing heating only

Page 61: JA-80

Heating

AC-82

Thermostat

Window detectors Control panelRemote controls

Telephone

Smart heating systemSmart heating system

Operating the heating by keypadON = normal heatingOFF = anti freezing heating only

Page 62: JA-80

Heating

AC-82

Thermostat

Window detectors Control panelRemote controls

Telephone

Smart heating systemSmart heating system

Operating the heating by a phoneON = normal heatingOFF = anti freezing heating only

Page 63: JA-80

Heating

AC-82

Thermostat

Window detectors Control panelRemote controls

Telephone

Smart heating systemSmart heating system

Operating the heating by windowsCLOSED = normal heatingOPEN = anti freezing heating only

Page 64: JA-80

Heating

AC-82

Thermostat

Window detectors Control panelRemote controls

Telephone

Smart heating systemSmart heating system

Robbery ALARM !!!!

Page 65: JA-80

Heating

AC-82

Thermostat

Window detectors Control panelRemote controls

Telephone

Smart heating systemSmart heating system

Freezing ALARM !!!!(heating is defective)

Page 66: JA-80

Heating

AC-82

Thermostat

Window detectors Control panelRemote controls

Telephone

Smart heating systemSmart heating system

Fire ALARM !!!!(temperature above 60 °C )

Page 67: JA-80

Heating

AC-82

Thermostat

Window detectors Control panelRemote controls

Telephone

Smart heating systemSmart heating system

Low battery in thermostat

Page 68: JA-80

Heating

AC-82

Thermostat

Window detectors Control panelRemote controls

Telephone

Smart heating systemSmart heating system

Communication lost with thermostat

Page 69: JA-80

““Many useful and intuitive features are Many useful and intuitive features are hidden within the system, disturbing neither hidden within the system, disturbing neither the installer nor the end user….”the installer nor the end user….”

OASiSOASiS brings security and comfort brings security and comfort

Page 70: JA-80

The UC-8014 multiple channel receiver

Power 230V AC 7 to 28 outputs Extra output for circulation pump Enrolls:

• thermostats• RC controllers • window detectors• control panel PG outputs

Designed for larger heating systems (floor heating systems and etc.)

Page 71: JA-80

Optional antennasCan be used with:

Control panel UC-82

AN-80

AN-81

Page 72: JA-80

The JA-80T PC cable Connects control panel to PC Provides USB interface Suitable for Comlink 80 and higher JA-80BT (Bluetooth option - 2007)

Page 73: JA-80

Comlink 80Comlink 80

Compatible with JA-6x and JA-80