JA-80 JA-80 Make your premises an Oasis of security JA-80_EN_042007_c1
Feb 02, 2016
JA-80JA-80Make your premises an Oasis of security
JA-80_EN_042007_c1
A solution for your security & comfort......
Oasis basic features:
50 addresses for wireless devices (detectors, RC, keypads and sirens)
50 positions for user codes or/and proxy cards
2 wired inputs in the control panel ( plus Inputs in keypad and detectors)
Lithium batteries – calculated lifetime 3 years
868 MHz operating frequency
Grade 2 by the EN 50131 standard (medium risk)
“LEGO” architecture
JK-81JK-81 kit kit
Devices supplied pre-enrolled and pre-programmed
Simple installation
JK-81JK-81 consists of: consists of: Control panel with GSM communicator Wireless keypad PIR detector Magnetic detector Indoor siren Key fob Wireless door bell button Proximity card Accessories (batteries etc.)
11
55 66
77
Installation in 7 steps Installation in 7 steps
33
44
22
Service mode after powering upService mode after powering up
AA:: Enrollment ofEnrollment of more devicesmore devices
• key key 11 and connect batteriesand connect batteries, , exitexit with with ##
BB: Communication quality test: Communication quality test
• keykey 298298 ( (turns on signal measurementturns on signal measurement))
• arrow keys scroll devicesarrow keys scroll devices
• device triggering = signal from 1/4 to 4/4device triggering = signal from 1/4 to 4/4
• # returns you to Service mode # returns you to Service mode
•CC:: GSM signal strength testGSM signal strength test
• keykey 992222
• return to Service mode by #return to Service mode by #
Each signal should be at leastEach signal should be at least 2/4 2/4
ProgrammingProgrammingExample:Example:
4 hh mm DD MM YY4 hh mm DD MM YY = = clockclock
220011 Exit delayExit delay 10sec. 10sec.
81 1 777 775 081 1 777 775 02222 00 = tel. = tel. numbernumber
92619261 = = forward forward SMSSMS
299299 enrollment of PGX to AC relay X enrollment of PGX to AC relay X232377 PGX function = on / off PGX function = on / off
Handover to the userHandover to the user
SET(arm)
UNSET(disarm)
Operating a key-fobOperating a key-fob
Both buttons Both buttons = = PANICPANIC
Keypad layoutKeypad layoutAlarm or fault SET A, B and C Power
DetailsSetting (arming)Hot keysA, B & C
PGXOn / Off
Detail reading
Let the user feel that (s)he is the masterLet the user feel that (s)he is the master
„Master“ card enrollment: 5 1234 card
Access card enrollment: 6, Master card, key nn, card
Access code programming: 6, Master card, key nn, code
To erase access code and card: 6, Master card, key nn, 0000
nn = user number 01 to 50Each user can have code, card or both
John 2375
Keypad operation Keypad operation Card / code Unsetting / Setting
ABC Complete setting
A Partial setting A (if used)
B Partial setting B (if used)
? Status details (open windows, PG, faults)
PGX on
PGX off
# Esc
Function
instructionsinstructions 1 ABC arming(=ABC button)
2 A arming(=A button)
3 B arming(=B button)
4 Memory reading
5 Master code / card changing
6 Access code / card programming
7 Operating under duress
8 PGX control (81/80 = on/off or 8 = 2sec. pulse)
9 PGY control (91/90 = on/off or 9 = 2sec. pulse)
0 Service or Maintenance ( 0 service or master code)
2 level partial arming
Evening armingGarage….
A
C
BA
KeyKey AAAA A
A
A
B
B
B
C
C
C
KeyKey B BA+BA+B
Key Key ABCABCA+B+CA+B+C
Night armingGround floor + garage
Complete arming
Example: Family house
Split systemExample: Two families in a house
Code or cardBush
If both A+B armed,then C also armed
A
C
B
A B
A B
BushARMED
BlairARMED
Entire house armed incl. Common section
Code or cardBlair
C
C
Communicator testCommunicator testBoth buttonsBoth buttonsPANIPANICC
Panic alarm SMS
Result:
Function test Knowing the SIM card tel. number
Remote access testingRemote access testingPhone keypad authorization: Call and wait for the system to respond (after 5 rings) Enter a valid code (master, user or service) Operate the system… hang up at the end
SMS instructions: „Code space INSTRUCTION“
SET Arming
UNSET Disarming
STATUS Status checking
MEMORY Last event memory checking
PGX ON Turning PGX on
PGX OFF Turning PGX off
PGY ON Turning PGY on
PGY OFF Turning PGX off
AUX ON Turning AUX on
AUX OFF Turning AUX off
CREDIT Prepaid SIM card balance checking
Control panel JA-80KFeatures 1: Back up battery 1.3Ah or 2.6Ah Standby consumption 50 mA Outputs:
EW - external warning (dry contact, max. 1A) IW - internal warning (switches to GND, max. 0.5A) PGX & PGY (switch to GND max. 0.2A) +U power, max. 0.4A
Built in transceiver Optional external antenna Up to 50 wireless devices
Selectable reactions (Natural or others) Assignment to sections (A, B, C) All devices have natural reaction in section C as factory-default Devices can also be enrolled by keying in their production codes
Control panel JA-80KHard-wired inputs (addresses 01 and 02)Maximum of 5 detectors in a loop, Differentiates between triggering and tamperingProgrammable reaction (Natural = delayed)Enrollment of a wireless device to address 01 or 02 disables the input terminal
Connected to COM via a 1 k resistor = untriggered input Connected to COM via 2 to 5 k = triggered input, Connected to COM via less then 700 or more then 7k8 k = tamper signal
Features 2: Two-level partial setting (A, AB, ABC) Or split system: A, B and C (common section) Devices and codes/cards can have reactions:
Off, Natural, Panic, Fire, 24hr., Next delay, Instant, Set, PG control, Set/Unset Up to 5 final-door detectors Intruder alarm confirmation by a 2nd detector Annual inspection request indication option Indication of permanently triggered detectors (details by ? key) Winter/Summer time automatic change (1st of November/1st of April) Memory for the last 255 events Replaceable memory chip
Can be operated with up to: 50 user codes (locally or remotely by phone or internet) 50 user cards Option: Confirmation of the card by code
Control panel JA-80K
The JA-80F keypad
LCD (2x 16 characters) 1st line = status or event 2nd line = name of the event source
Keypad menu – 15 languages and Chime feature Built in proximity card readers Hard-wired input IN (NC,
Natural reaction = Delayed) Arrow keys allow you to control PGX (81 and 80)
A, B & ABC arming hot keys
? Detail reading
Keypad turns off after 20sec (if battery powered) 2 x AA Lithium 3V batteries (3 year lifetime - 2 operations/day)
JA-80E = hard-wired version
Keypad text editingIn service mode: Holding ? pressed opens editing Keys:
Arrow – selects the text string to be edited 1 and 7 - scroll through characters (A, B, C…..8,9,0)4 and 5 - move cursor 2 deletes character# exits editing
Comlink SW allows more convenient editing (special signs / letters enabled) - keypad must be connected to the control panel bus
The PC-01 proximity card RFID access card (EM UNIQUE 125kHz)
Up to 50 cards can be enrolled to the system The card has the same function as an access code For higher security the card can be combined with a code PC-02 is a key tag version
The JA-80H outdoor keypad Built in RFID reader Connects to the control panel bus via WJ-80 Provides a doorbell button Illuminated keys IP-65 Standby consumption 45 mA
The JA-80N outdoor reader RFID card reader Connects to the control panel bus via WJ-80 IP-65 Standby consumption 40 mA
The WJ-80 interface Connects outdoor keypad (reader) to the control panel Built-in door bell transmitter (for JA-80L) Output to operate an electrical door lock (Z8-12V) Provides output to operate the electric strike of an
electrical door lock an open button input Keypad uses Wiegand protocol 26b DIP switches:
1. System keypad / Outdoor bypass switch2. PGY can operate the door lock as well (Y/N)3. Door lock activation time 3 / 6 seconds4. Exit & entrance beeps (Y/N)
Control panel bus
Sequence248 = PGY pulseAuthorized phone opening777 775 0229To program81 1 777 775 022 *79*0
The RC-80 key-fob 2 housings provided (2 or 4 buttons) Key lock (4 buttons only) Can also be used with UC, AC, JA-80L an CA-180x Alkaline battery 6V, life time 2 to 3 years Working range up to 100m
The RC-88 button
DIP switches: Panic (remote control or panic button function) TMP (disable tamper sensors and communication supervision)
Can also be used with UC, AC and JA-80L 1x 1/2 AA Lithium 3V battery
(3 year life time, max. 20 activations/day)
The RC-89 door bell button Works with the JA-80L indoor siren Can be enrolled to the control panel as a portable panic
button (by keeping pressed for 3 seconds) Can also be used with AC and UC modules No radio communication supervision 6V alkaline battery Working range up to 200m
Mr. Jones
The RC-87 personal panic button Can be enrolled to the control panel, siren or UC/AC modules Optional
Wrist watch or necklace version Audible confirmation of triggering Delay (10s) to stop accidental triggering
No radio communication supervision CR2032 lithium battery Working range up to 200m
HW in testing
The RC-85 remote control module Designed to be installed in a car (from 12V to 24V) 3 wires
GND A = if connected to +U transmits signal B = if connected to +U transmits signal both A + B connected to +U transmits a panic signal
Works with the control panel, UC, AC and JA-80L No battery, powered by car Flashing full-beam headlights or blowing the horn send signals Can also be used to transmit an alarm from a car alarm Optional to choose “double click” activation
The JA-80P detector PIR sensor Hard-wired input IN (initiate same reaction as PIR) 15 min test mode after closing the cover 5 min sleep time (can be shortened to 1 minute) DIP switches
DEL / INS (natural reaction) NORM / HIGH (immunity level)
Covers 120° / 12m Optional lenses (pet, long corridor, vertical curtain)
1 x AA Lithium battery 3V (3 year life time)
úhel záběru(poh led shora)
2
2,5
1,5
1
0,5
1,6 3,7 12 dosah[m]
výška[m]
Pracovní dosah - pohled z boku
120º
12m
zóna A
zóna B
zóna C
zóna A
zóna Bzóna C
The JA-80PB detector PIR sensor + glass-break sensor Enrolls to 2 addresses in the system PIR = identical to JA-80P GB detection - up to 9m (GBT-212 tester) 15 min test mode after cover closing Glass-break DIP switches
DEL / INS (natural reaction) PIR / GBS (LED indicator function in test mode)
2 Lithium 3V batteries: 1 x AA + 1x 1/2 AA
úhel záběru(poh led shora)
2
2,5
1,5
1
0,5
1,6 3,7 12 dosah[m]
výška[m]
Pracovní dosah - pohled z boku
120º
12m
zóna A
zóna B
zóna C
zóna A
zóna Bzóna C
PIR sensor + CMOS camera PIR = identical to JA-80P 2 way communication Processing module in the control panel If armed and a movement detected = takes pictures
1st immediately without flash 2nd & 3rd with flash High resolution stored to internal memory (USB) Low resolution sent to server (within 25sec)
2 Lithium 3V batteries AA sizeúhel záběru
(poh led shora)
2
2,5
1,5
1
0,5
1,6 3,7 12 dosah[m]
výška[m]
Pracovní dosah - pohled z boku
120º
12m
zóna A
zóna B
zóna C
zóna A
zóna Bzóna C
Working samples
The JA-84P detector & camera
The JA-89P detector Outdoor PIR sensor 2 sensors eliminate small animals Adjustable detection angle IP-54 cover Installation height 0.8 - 1.2 m 1 x AA Lithium battery 3V (3 year life time) Based on the Optex product
Working samples
Covered area adjustable not covered area
The JA-80M detector Magnetic door / window detector Status detector (optional pulse reaction) DIP switches:
DEL / INS (natural reaction) MG ON / MG OFF (enables/disables internal sensor)
2 input terminals: TMP = tamper input IN = alarm input
1x 1/2 AA Lithium 3V battery (3 year life time for 20 activations/day)
m a x. 5 m mm
agne
t
LIT
HIU
M3V
1/2
AA
+
M G O FF
M G O N
tam per sw itch
externalsensor
Reaction
m ag. sensor O N/O FF
INSTAN T
DELAYED
The JA-82M detector Invisible window (door) detector (EURO or wooden) To be installed in the frame of a window (door) DIP switches:
INS / DEL TMP on / off Status / pulse reporting
Communicating range up to 200 meters 2 x CR2354 Lithium 3V battery
(3 year life time 5 activations/day)
A
B
Prototypes
The JA-80S detector
LITHIUM 3V AA+
Int. S iren
O n
O ff
Reaction
Fire
Instant
Fire detector (optical smoke + temperature over 60°) Testing by test button or by aerosol Optional to disconnect siren by test button in alarm Jumpers:
FIRE / INS (natural reaction) SIREN ON / OFF (enables / disables internal siren)
1x AA Lithium 3V battery (3 year life time)
The JA-80G detector Combustive gas or fume detector Mains powered Can be tested with a cigarette lighter DIP switches:
10 / 20% LEL (gas concentration) MEM ON / OFF (memory function)
Output relay contact max. 6A
Prototypes
The JA-85P detector Mini-size PIR detector Can be used in a house or in a car (CA-1802 or 1803) 15 min test mode after closing the cover DIP switches
NORM / HIGH (immunity level) DEL / INS (natural reaction) Supervision ON / OFF Sleep 1 / 5 minutes
Semi-sphere lens max. detection distance 5m Communicating range up to 200 meters 1 x AA Lithium 3V battery
(3 year life time)
The JA-85B detector Mini-size glass-break detector Can be used in a house or in a car (CA-1802 or 1803) 15 min test mode after closing the cover DIP switches
DEL / INS (natural reaction) Supervision ON / OFF
Detection up to 9 meters (can be tested with GBT-212) Communicating range up to 200 meters 1 x AA Lithium 3V battery
(3 year life time)
The JA-80L indoor siren Mains powered
Tampering reported if disconnected from the power during an alarm = ALARM CONFIRMATION
Enrolls by plugging in Generates sounds:
IW alarm Exit and entrance beeps Door bell - 8 melodies Detector - triggered sounds - 8 melodies
LED indicates PGY status Two volume levels (by keeping the button pressed) Triple click enables/disables arming chirp sounds Signal level measurement – by pressing button
The JA-80A outdoor siren Totally wire-free !!! Loudness increases gradually Max. duration of the siren sound: 3 min. Flashes 30 min. after the alarm Jumpers:
50 / 25 s. (communication cycle with the control panel) LED ON / OFF (warning flash every minute)
Enrolls by connecting its battery Lithium battery BAT-80 (max. life time 3 to 5 years)
S ire n c o nn e c to r(b e w a re o f h ig h v o lta g e s )
L E D s
To p c ov e r s e ns o r S ire n re m ov a l s en s o r
B a tte ry co n n e c to r
enabled
disabled
communication
interval 25s
interval 50s
LED indication
a n te n n a
The JA-80Y communicator Communication via GSM/GPRS GSM gateway function Events reporting by:
SMS (15 lang. Selection) phone calls ARC (IP, SMS or CID protocols), ARC
programming can be locked Remote access via:
Phone (keypad registration or SMS) Internet - www.gsmlink.cz Unanswered ringing from an authorized phone
number ARC programming can be locked Remote access possible with a valid code
(UC, MC, SC)
Combination of LAN and PSTN enables the same features as GSM / GPRS.
Most of the JA-80V and JA-80Y functions are identical
The JA-80V communicator Communication via LAN & PSTN Events reporting by:
SMS (15 lang. selection) phone calls ARC (IP, CID or DR protocols) ,ARC
programming can be locked Remote access via:
Phone (keypad registration or SMS) Internet - www.gsmlink.cz Unanswered ringing from an authorized phone
number Remote access possible with a valid code
(UC, MC, SC)
INTERNETINTERNET
Events reportingEvents reporting
OasisOasis
Telephone networkTelephone network
AutomaticAutomaticReceivingReceivingCenter Center
andandoror
UserUsernotificationnotification
Remote accessRemote accesswww.GSMLink.czwww.GSMLink.cz
INTERNETINTERNET
InternetInternet TTelephoneelephone
aandndoror
The JA-80X voice communicator Reports alarms with voice messages Up to 4 phone numbers via PSTN 7 voice messages
System name Intrusion Fire Tampering Panic Technical alarm Remote access welcome note
Allows remote access via telephone keypad authorization (DTMF)
Supports CID protocol transmission to ARC (PSTN line) Can be combined with JA-80V or JA-80Y
Prototype
The SP-02 speaker phone For listening in and talking Can be connected to PSTN or to the phone line
simulated by JA-80Y Answers calls from authorized numbers Half-duplex communication allows a high sensitivity
for listening Push-to-talk feature to call an emergency number 2 x AA alkaline 1.5V battery
Prototype
The UC-82 relay module Powered by 12V DC 2 output relays (X & Y) - max 2A Low bat. output External antenna is optional Powered by 12V (20mA) external source Can be used with:
Control panel Detectors RC-8x transmitters
no. Reaction Device Enrolls with Max. number
key fob button pressing 1 impulse 1 sec. detector battery connecting
60
key fob button pressing 2 impulse 2 min. detector battery connecting
60
latch key fob button pressing 60 3 tamper detector battery connecting 8
key fob button pressing 60 on / off PG outputs of
control panel entry of 299 in Service mode
1 4
triggering detector battery connecting 8
buttons
P C B tab
Y
Y
X
X
tam persw itch
ext.an tenna connector
RA
DIO
1234
LED s
The AC-82 relay module Powered directly from mains 230V, 50Hz 2 output relays (X and Y) - max 5A Can be used with:
Control panel Detectors RC-8x transmitters TP-8x thermostats
no. Reaction Device Enrolls with Max. number
key fob button pressing 1 impulse 1 sec. detector battery connecting
60
key fob button pressing 2 impulse 2 min. detector battery connecting
60
latch key fob button pressing 60 3 tamper detector battery connecting 8
key fob button pressing enrolls pair of buttons
60
PG outputs of control panel
entry of 299 in Service mode
1 on / off
thermostat battery connecting 8
4
triggering detector battery connecting 8
1234
RA
DIO
ma
x F
5 A
/ 25
0V
buttons
LEDs
fusem ax 5 A
X Y
The TP-80 thermostat Enrolls to AC-82 Transmits signals:
Temperature below target (normal heating) Below 6°C (anti-freezing) Below 3°C (Freezing alarm - Panic) Above 60°C (Fire alarm) Supervision and battery status
Normal heating can be enabled or disabled in the AC-82 receiver by signals from the control panel (PG), remote controls or detectors
1 AA alkaline battery 1.5V, 1 year lifetime
The TP-82 thermostat Enrolls to AC-82 Indicates temperature Transmits signals:
Temperature below target (normal heating) Below 6°C (anti-freezing) Below 3°C (Freezing alarm - panic) Above 60°C (Fire alarm) Supervision and battery status
Normal heating can be enabled or disabled in the AC-82 receiver by signals from the control panel (PG), remote controls or detectors
1 AA alkaline battery 1.5V, 1 year life timeTP-83 weekly temperature programming ( 3Q 2007)
Simple heating control
Thermostat AC-82
Radio Cable
Thermostat is enrolled to the AC receiver
Heating
AC-82
Thermostat
Window detectors Control panelRemote controls
Telephone
Smart heating systemSmart heating system
Thermostat is enrolled to the AC receiver and also to the control panel
Normal heating controlHeating = ON
Heating
AC-82
Thermostat
Window detectors Control panelRemote controls
Telephone
Smart heating systemSmart heating system
Heating
AC-82
Thermostat
Window detectors Control panelRemote controls
Telephone
Smart heating systemSmart heating system
Operating heating by remote controlsON = normal heatingOFF = anti-freezing heating only
Heating
AC-82
Thermostat
Window detectors Control panelRemote controls
Telephone
Smart heating systemSmart heating system
Operating the heating by keypadON = normal heatingOFF = anti freezing heating only
Heating
AC-82
Thermostat
Window detectors Control panelRemote controls
Telephone
Smart heating systemSmart heating system
Operating the heating by a phoneON = normal heatingOFF = anti freezing heating only
Heating
AC-82
Thermostat
Window detectors Control panelRemote controls
Telephone
Smart heating systemSmart heating system
Operating the heating by windowsCLOSED = normal heatingOPEN = anti freezing heating only
Heating
AC-82
Thermostat
Window detectors Control panelRemote controls
Telephone
Smart heating systemSmart heating system
Robbery ALARM !!!!
Heating
AC-82
Thermostat
Window detectors Control panelRemote controls
Telephone
Smart heating systemSmart heating system
Freezing ALARM !!!!(heating is defective)
Heating
AC-82
Thermostat
Window detectors Control panelRemote controls
Telephone
Smart heating systemSmart heating system
Fire ALARM !!!!(temperature above 60 °C )
Heating
AC-82
Thermostat
Window detectors Control panelRemote controls
Telephone
Smart heating systemSmart heating system
Low battery in thermostat
Heating
AC-82
Thermostat
Window detectors Control panelRemote controls
Telephone
Smart heating systemSmart heating system
Communication lost with thermostat
““Many useful and intuitive features are Many useful and intuitive features are hidden within the system, disturbing neither hidden within the system, disturbing neither the installer nor the end user….”the installer nor the end user….”
OASiSOASiS brings security and comfort brings security and comfort
The UC-8014 multiple channel receiver
Power 230V AC 7 to 28 outputs Extra output for circulation pump Enrolls:
• thermostats• RC controllers • window detectors• control panel PG outputs
Designed for larger heating systems (floor heating systems and etc.)
Optional antennasCan be used with:
Control panel UC-82
AN-80
AN-81
The JA-80T PC cable Connects control panel to PC Provides USB interface Suitable for Comlink 80 and higher JA-80BT (Bluetooth option - 2007)
Comlink 80Comlink 80
Compatible with JA-6x and JA-80