2344 Schedule of External Materials Project - Exeter College, Walton Street Client- Exeter College Date - 12.01.15 Item No. Item Material Floor Area / Room Finish Size (Visible) G Value Specification Notes Drawing Reference Image 1.1 Roof Rimex Stainless Steel Sh First - Fourth Roof Finish: Rimex Stainless Steel Bronze 335 x 335 H76/ 120 A0070 Rimex Stainless Steel Shingles Extensive Green Roof Paladin Pattern A0071 Granex Bead Blasting M1A A0072 A0073 First - Fourth Roof Finish: Rimex Stainless Steel Champagne 335 x 335 H76/ 120 A0170 to A0172 Paladin Pattern Granex Bead Blasting M1A Granex Bead Blasting M1A Bronze Colour Typical Sedum Roof Fourth Ridge / Hip Standing Seam Finish: Rimex Stainless Steel Bronze H75 / 330 A0170 to A0172 Paladin Pattern Paladin Pattern Granex Bead Blasting M1A 1.2 Slate Third Roof lsating to the Walton Street Parapet Welsh Slate, Bugail Dark Blue / Grey H62 / 105 A0170 to A0172 Champagne Colour Existing Slates to be Reused 1.3 Green Roof Ground Extensive Green Roof to Bauder Green Roof System Q37 / 130 A0170 1.3 Green Roof Ground Extensive Green Roof to the Hall Bauder Green Roof System Q37 / 130 A0170 2.1 Rain Water Goods Gutter First Gutter Finish: Rmex Stainless Steel Bronze H75 / 215 A0070, 71, 72, 73 Rimex Stainless Champagne Steel Shingles Paladin Pattern A1120 Granex Bead Blasting M1A 2.2 RWP RWP - Ruskin Facade As existing. All RWP / Goods to the Ruskin Facade, as existing - Refurbished. A0070 2.2 RWP RWP - West Elevation TBC All RWP other than those to the west elevation of 2.2 RWP RWP - West Elevation West Wing TBC All RWP other than those to the west elevation of the West Wing, concealed within the building fabric. 3.1 Walls Stone Basement - First Hartham Park Lime Stone - Top Bed F21 / 110 A0070 Hartham Park Lime Stone A0071 Hartham Park Lime Stone - Base Bed F21 / 115 A0072 A0073 A3000 to A3009 A3009 3.2 Metal First Mezzanine Plant Room Screen Laser cut Steel Plates with Diagonal Patter, PPC Steel, Syntha Pulvin Metalic Range to match RAL Analok 543 L10 / 600 A0072 Timber South Gable Wall - Built in facsimile 3.3 Timber Third Species: IPE, Profile Chamfered 3.3 Timber Third Timber Weatherboarding to the Roof Terrace Species: IPE, Profile Chamfered 75mm H21 / 116 TBC 3.4 Brick Ground - First South Gable Wall Brickes reused from existing facade A0071 4.1 Curtain Glazing Glazing Basement - Ground Learning Commons Frame: PPC Metalic Bronze Steel 0.5 W/m2K H11 / 110 L10 / 330 For detailed values per window refer to 2344-SH- 0001 and 2344-SH-0002, Glazing Shedule. A5008 A5009 Anodised Aluminium Cills and Reveals: Anodised Aluminium Bronze Analok 541 H72 / 160 Anolok 541 Anolok 543 Ground Hall Frame: PPC Metalic Bronze Steel 0.4 W/m2K H11 / 110 For detailed values per window refer to 2344-SH- 0001 and 2344-SH-0002, Glazing Shedule. A5010 Cills and Reveals: Anodised Aluminium Bronze Anolok 541 H72 / 160 Powder Coated Stainless Steel Ground Curtain Glazing Generally Schucco Frame: Anodised Aluminium Bronze Anolok 543 0.4 W/m2K H11 / 115 For detailed values per window refer to 2344-SH- 0001, Glazing Shedule. A5000 to A5013 Metalic Bronze Steel Cills and Reveals: Anodised Aluminium Bronze Analok 541 H72 / 160 Ground South Cloister Frame: Plant on system, with Anodised For detailed values per window refer to 2344-SH- Ground South Cloister Frame: Plant on system, with Anodised Aluminium Caps Anolok 543 0.3W/m2K H11 / 120 For detailed values per window refer to 2344-SH- 0001 and 2344-SH-0002, Glazing Shedule. A5006 A5007 Cills, Reveals and Bespoke Capping: Anodised Aluminium Bronze Analok 541 H72 / 160 165
4
Embed
Item No. Item Material Floor Area / Room Finish ... - Oxfordmycouncil.oxford.gov.uk/documents/s22611/Former...Galvanised Mild Steel Oxford Two Tier Shelter, Cycle Pod Shelter Q50
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
2344 Schedule of External Materials
Project - Exeter College, Walton Street
Client- Exeter College
Date - 12.01.15
Item No. Item Material Floor Area / Room Finish Size (Visible) G Value Specification Notes Drawing Reference Image
Ground South Cloister Frame: Plant on system, with Anodised For detailed values per window refer to 2344-SH-Ground South Cloister Frame: Plant on system, with Anodised
Aluminium Caps Anolok 543 0.3W/m2K H11 / 120
For detailed values per window refer to 2344-SH-
0001 and 2344-SH-0002, Glazing Shedule.A5006
A5007
Cills, Reveals and Bespoke Capping:
Anodised Aluminium Bronze Analok 541 H72 / 160
165
2344 Schedule of External Materials
Project - Exeter College, Walton Street
Client- Exeter College
Date - 12.01.15
Ground North Cloister0.4 W/m2K H11 / 120
For detailed values per window refer to 2344-SH-
0001 and 2344-SH-0002, Glazing Shedule.A5013
Cills, Reveals and Bespoke Capping:
Anodised Aluminium BronzeAnalok 541 H72 / 160
Third Fellows Studies Composite Frame: Protec Anodised
Aluminium Bronze Anolok 5430.3 W/m2K H11 / 125
For detailed values per window refer to 2344-SH-
0001 and 2344-SH-0002, Glazing Shedule.A5012
Cills and Reveals: Anodised Aluminium
Bronze Anolok 541H72 / 160
Fourth Senior Common Room Composite Frame Sliding Door: Frame: