Description Technical data Accessories Downloads ITEM 098582 CES-AR-C01-EH-SA Features Safety switch with integrated evaluation electronics Up to 20 switches in series Short circuit monitoring 2 safety outputs (semiconductor outputs) Category 4 / PL e according to EN ISO 13849-1 Fixcode evaluation (incl. actuator CES-A-BPA) Approach direction Can be adjusted in 90° steps Short circuit monitoring The switch generates its own clock signal on the output cables OA/OB. Pay attention to this aspect when connecting to control systems and relays. Fixcode evaluation An actuator CES-A-BPA is permanently allocated to the switch. The switch can be operated only with this actuator. The actuator is taught-in at EUCHNER prior
14
Embed
ITEM 098582 CES-AR-C01-EH-SAria-groupp.com.ua/pdf/euchner/20953.pdf · Description Technical data Accessories Downloads ITEM 098582 CES-AR-C01-EH-SA Features Safety switch with integrated
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Description Technical data Accessories Downloads
ITEM 098582 CES-AR-C01-EH-SA
Features
Safety switch with integrated evaluation electronicsUp to 20 switches in seriesShort circuit monitoring2 safety outputs (semiconductor outputs)Category 4 / PL e according to EN ISO 13849-1Fixcode evaluation (incl. actuator CES-A-BPA)
Approach direction
Can be adjusted in 90° steps
Short circuit monitoring
The switch generates its own clock signal on the output cables OA/OB. Payattention to this aspect when connecting to control systems and relays.
Fixcode evaluation
An actuator CES-A-BPA is permanently allocated to the switch. The switch canbe operated only with this actuator. The actuator is taught-in at EUCHNER prior
to delivery. No additional actuators can be taught-in.
Category according to EN 13849-1
Due to two redundantly designed semiconductor outputs (safety outputs) withinternal monitoring suitable for:
Category 4/PL e according to EN 13849-1Important: To achieve the stated category in accordance with EN ISO 13849-1,both safety outputs (OA and OB) must be evaluated.
LED indicator
STATE Status LEDDIA Diagnostics LED
Additional connections
OUT Monitoring output (semiconductor)RST Reset input
Typical operating distance
With actuator CES-A-BPA
FigureFor a side approach direction for the actuator and safety switch, a minimumdistance of s = 6 mm must be maintained so that the operating distance of theside lobes is not entered.
Connector assignment
Plug connector (view ofconnection side)
Pin Designation Function Wire colorconnectioncable
1 IB Enable inputfor channel 2
WH
2 UB Power supply,DC 24 V
BN
3 OA Safety output,channel 1
GN
4 OB Safety output,channel 2
YE
5 OUT Doormonitoringoutput
GY
6 IA Enable inputfor channel 1
PK
7 0V Ground, DC 0V
BU
8 RST Reset input RD
Plug connector (view ofconnection side)
Pin Designation Function Wire colorconnectioncable
Approvals
Components included in the set
098775 Actuator CES-A-BPAFeatures
Mechanical figures and environment
Housing material Plastic, PBTGround
Net 0,12 kgAmbient temperature -20 ... 55 °CDegree of protection IP67Resilience to vibration In acc. with EN IEC 60947-5-2Mounting distance min. 40 mmInstallation position AnyTightening torque
External (operating voltage) 0,25 ... 8 ARated insulation voltage U 300 V Rated impulse withstand voltage U max. 1,5 kVEMC protection requirements In accordance with EN IEC 60947-5-3 and EN IEC 61326-3-
1Degree of contamination (external,according to EN 60947-1)
3
Switch-on timeSafety outputs max. 400 ms
Safety class IIIRisk time according to EN 60947-5-3
Delay per device 5 msSingle device max. 260 ms
Monitoring output OUTType of output p-switching, short circuit-proofSwitching current max. 200 mAOutput voltage 0,8 x UB ... UB V DC
Safety outputs OA/OBTest pulses max. 1 msType of output Semiconductor outputs, p-switching, short circuit-proofSwitching current
per safety output 1 ... 400 mAOutput voltage
HIGH U(OA) / U(OB) UB-1,5 ... UB V DC LOW U(OA) / U(OB) 0 ... 1 V DC
Utilization category acc. to EN 60947-5-2
DC-13 24V 400mA Rated conditional short-circuit current max. 100 AOff-state current I max. 0,25 mATime difference max. 10 ms
Operating distance
Repeat accuracy RAccording to EN 60947-5-2 ≤ 10
Miscellaneous
For the approval according to UL thefollowing applies
Operation only with UL class 2 power supply, or equivalentmeasures
Reliability values according to EN ISO 13849-1
Monitoring of the safety guard positionCategory 4
i [1]
imp
[2]
[3]
[4]
r
Performance Level PL ePFH 2.1 x 10
Mission time 20
In combination with Actuator CES-A-BPA
Operating distance
Switch-on distance 22 mm Assured switch-off distance S max. 58 mmAssured operating distance S min. 18 mmSwitching hysteresis 1 ... 2 mm
Tested by BG up to 75V Values at a switching current of 50 mA without taking into account the cable lengths.
Caution: outputs must be protected with a free-wheeling diode in case of inductive loads. Applying the limit value from EN ISO 13849-1:2008, section 4.5.2 (MTTFd = max. 100
years), BG certifies a PFHd of max. 2.47 x 10 . For surface mounting on aluminum. In a non-metallic environment the typical operating
distance increases to 30 mm
Dimension drawing
d -9 [5]
[6]
arao
[1]
[2, 3]
[4]
[5]-8
[6]
Legende
1 LED status indication2 Active face
Dimension drawing
Legende
1 Active face2 Active face
Wiring diagram
Connection material
Connection cable with plug connector M12, 8-pin, 5m
113189 C-M12F08-08X025PU10,0-MA-113189FeaturesM12 female plug, 8-pinAngled plug connectorCable outlet C (left)PUR cableCable length 10 mWith flying lead
Y-distributor M12 with connection cable
111696 Y-VERTEILER M12 MIT ANSCHLUSSKABELFeaturesY-distributor M12 with connection cable, 2 x 5-pin, 1 x 8-pinStraight plug connectorPVC cableCable length 0.2 m
112395 Y-VERTEILER M12 MIT 1M KABELFeaturesY-distributor M12 with connection cable, 2 x 5-pin, 1 x 8-pinStraight plug connectorPVC cableCable length 1 m
Connection cable with plug connector M12, 8-pin, 30m
120861 AC-DP-04-SA-120861FeaturesConnection of up to 4 CES-AR, CET-AR, CTP-AR and ESL-ARLEDs for the indication of the door position on each portCan be connected in series
082220 RIEGEL CES-A-CFeaturesSteel boltFor non-contact safety switch CES-A-C.../CES-A-W.../CES-AR...For left or right hinged doorsBall detent mechanism in closed positionCan be locked in open position with padlocksActuator included
Bolt CES-A-C/F with escape release
098357 RIEGEL CES-A-C/FFeaturesSteel boltFor left or right hinged doorsLever for escape release from the danger areaFor non-contact safety switches CES-A-C.../ CES-A-W.../ CES-..-C01-…Connection via M12 plug connectorDetent knob in open positionCan be locked in open position with padlocksCES actuator integrated in the bolt tongue