IT Energy Savings for Non-Techies

Identifying & Understanding Opportunities

September 2013

Mike Walker, President Beacon Consultants Network Inc. (An ENERGY STAR Technical Support Contractor)

Page 2: IT Energy Savings for Non-Techies - State Electronics Challenge

2

Who are we?

• Work on behalf of EPA’s ENERGY STAR program as “technical support contractors”

• 3 core areas of expertise: – Large scale “human behavior change” – IT management & consulting – Energy efficiency, sustainability

• Vendor/product/solution neutral • Our services are free -- we get paid by EPA

Page 3: IT Energy Savings for Non-Techies - State Electronics Challenge

3

EPA as IT energy efficiency advisors

• Developed 1st system to centrally manage PC power

• Worked with Microsoft to improve Windows Vista, 7

EZ GPO is a free tool for network administrators

Page 4: IT Energy Savings for Non-Techies - State Electronics Challenge

4

EPA as IT energy efficiency advisors, cont.

• Developed ENERGY STAR ratings for: – Servers, PCs, copiers, printers, etc. – Data centers – UPS* systems – Coming soon: data storage and data center cooling

• Advised/assisted hundreds of organizations

*UPS stands for Uninterruptable Power Supply

Page 5: IT Energy Savings for Non-Techies - State Electronics Challenge

5

Why are we here today?

1. Misaligned incentives in most large orgs

2. Most IT pros don’t have the required technical expertise

• We’ve figured out how to move you past these barriers

• EPA has documented enormous potential IT energy savings, but the savings remain untapped

Page 6: IT Energy Savings for Non-Techies - State Electronics Challenge

6

Overcoming barriers to IT energy savings: resources

• Vendor-neutral technical consultations for saving energy – Power managing networked computers – Data centers – Misc. IT & plug load

• Software solutions for CPM • Savings estimates • Power metering studies • Public recognition

Page 7: IT Energy Savings for Non-Techies - State Electronics Challenge

7

Imagine…

Page 8: IT Energy Savings for Non-Techies - State Electronics Challenge

8

Imagine…

Page 9: IT Energy Savings for Non-Techies - State Electronics Challenge

9

Page 10: IT Energy Savings for Non-Techies - State Electronics Challenge

10

IT Energy Savings: 4 Opportunities

1. Power-manage networked computers 2. Specify ENERGY STAR for all office equipment

purchases 3. Computer peripherals & misc. plug load 4. Data centers

Page 11: IT Energy Savings for Non-Techies - State Electronics Challenge

What is “CPM”, and why should I care?

Page 12: IT Energy Savings for Non-Techies - State Electronics Challenge

12

Energy saving features on every computer

• Automatically place inactive computer (not just monitor) into low power mode

• Wakes upon mouse or keyboard input

“CPM” settings must be activated!

• Built into Windows, Mac OS X, some Linux OSs – “Standby” and “hibernate” on PC – “Sleep” on Mac

Page 13: IT Energy Savings for Non-Techies - State Electronics Challenge

13

Would you leave your office like this every night?

Page 14: IT Energy Savings for Non-Techies - State Electronics Challenge

14

Page 15: IT Energy Savings for Non-Techies - State Electronics Challenge

15

Why power management?

• electricity consumption by $10-100/PC/yr. • cooling loads (saves additional $3-30/PC/yr.) • peak load demand charges • air pollution • carbon footprint • Executive Order 13423 requires federal

agencies to activate “sleep” features

Page 16: IT Energy Savings for Non-Techies - State Electronics Challenge

16

“Plug load” in office buildings is mostly computers

• Source: Office Plug Load Field Monitoring Report, CEC, October 2008. • CA study of 47 buildings that metered 7,000 plug load devices. • Business equipment = paper shredders, adding machines, portable lamps, and coffee makers.

Page 17: IT Energy Savings for Non-Techies - State Electronics Challenge

17

Monitor power management: no-brainer

• Easy to activate • Can’t interfere with software patching • Saves $10-35+ per monitor annually

Most organizations already utilize MPM features – but make sure!

Page 18: IT Energy Savings for Non-Techies - State Electronics Challenge

18

Computer power management: more challenging, more savings

• Drops power draw from 40-100+ to 1-3 watts

• Wakes up in a few seconds

• Saves $10-40 per PC annually – Can save > $100 if

monitor sleep hasn’t already been deployed

Microsoft Windows 7 Power Options

Page 19: IT Energy Savings for Non-Techies - State Electronics Challenge

19

For optimal savings & user experience, EPA recommends:

• Set display to enter sleep mode after 5-20* minutes of inactivity

• Set computer to enter system standby/hibernate/sleep after 30-60 minutes – Change “AC” or “Plugged in” profile, not “On battery” – Disregard “Turn off hard disks”

• The lower the settings, the more energy you save

Page 20: IT Energy Savings for Non-Techies - State Electronics Challenge

20

Two challenges

1. Activating settings on many computers at once

2. Ensuring that sleep settings don’t interfere with periodic distribution of software updates – E.g., Windows security patches, antivirus definitions

Numerous solutions exist, including admin tools that you may already own, and free software

Page 21: IT Energy Savings for Non-Techies - State Electronics Challenge

21

CPM offers a compelling return on investment (ROI)

• Software costs: ~ $0-15 / seat – Many solutions are free – Commercial solutions: $3-15 per PC

• Labor costs: ~ $5 / seat – Identifying appropriate solutions – Testing & troubleshooting exceptions – Ensuring that sleeping computers still get

software updates

• Vs. energy savings of $120-$160 / seat!

Assumptions: 1000 seats; labor costs = 2 weeks of work for one network administrator @ $2,500 per week

Page 22: IT Energy Savings for Non-Techies - State Electronics Challenge

22

Myth or reality?

You’d actually save more energy – and a lot of trouble – if you simply

required people to turn off their computers each night.

Page 23: IT Energy Savings for Non-Techies - State Electronics Challenge

23

The verdict: myth!

• Surveys and interviews with IT managers consistently conclude that policies “requiring” users to turn off their PCs at night result in only about 70-90% compliance

• You only save a watt or two by turning off a computer vs. placing it in sleep mode

• Forgetting to shut down your computer just a handful of times will negate an entire year’s worth of incremental energy savings

Page 24: IT Energy Savings for Non-Techies - State Electronics Challenge

24

Case Study: West Hartford Public Schools

• Challenge: – Monitor power management not activated – Most PCs were not being turned off after hours

• Solution: – EZ GPO (free software from ENERGY STAR)

• Results: – More than 3,000 computers sleep when they are inactive

• Monitors sleep after 30 min of idle • Computers sleep after 40 min

– Avg. of $63.86 savings per PC annually

Page 25: IT Energy Savings for Non-Techies - State Electronics Challenge

25

IT Energy Savings: 4 Opportunities

1. Power-manage networked computers 2. Specify ENERGY STAR for all office equipment

purchases 3. Computer peripherals & misc. plug load 4. Data centers

Page 26: IT Energy Savings for Non-Techies - State Electronics Challenge

26

ENERGY STAR-qualified Office Equipment

Coming soon: uninterruptible power supplies, data center storage, small network equipment, products using battery charging systems

Page 27: IT Energy Savings for Non-Techies - State Electronics Challenge

27

New ENERGY STAR Servers can Consume 54% Less Power

• Replacing an older server with a new ENERGY STAR-qualified model will save energy and deliver more processing power in the bargain

Page 28: IT Energy Savings for Non-Techies - State Electronics Challenge

28

ENERGY STAR qualified vending machines can save $150 / yr

• Typically use 7x more energy than a refrigerator • Nationwide stock (3 million) uses more energy than

Delaware

=

Misc. Office Plug Load

Ask your vending service co. to provide ENERGY STAR vending machines or retrofit kits -- or use a VendingMiser® device

Sample procurement language: www.energystar.gov/index.cfm?c=vending_machines.pr_proc_vendingmachines

Page 29: IT Energy Savings for Non-Techies - State Electronics Challenge

29

IT Energy Savings: 4 Opportunities

1. Power-manage networked computers 2. Specify ENERGY STAR for all office equipment

purchases 3. Computer peripherals & misc. plug load 4. Data centers

Page 30: IT Energy Savings for Non-Techies - State Electronics Challenge

30

“Smart” Power Strips can Save $10-100+ per Year

Lighting, printer/scanner, PC speakers, backup drives, space heaters, etc.

Monitor (sleep mode triggers switch)

Computer, phone charger

Your utility may offer discounts/rebates

Page 31: IT Energy Savings for Non-Techies - State Electronics Challenge

31

Consolidate Printers

• Reduce the number of devices • Ensure that remaining devices are cost effective:

– Eliminate inkjet & other high-cost printers – Share “workgroup” printers – Use multi-function devices

• Benefits: – Save electricity – Reduce hardware costs – Reduce maintenance expenses – Cut paper, ink, and toner costs

Savings: 30-60% of printing budget

Page 32: IT Energy Savings for Non-Techies - State Electronics Challenge

32

IT Energy Savings: 4 Opportunities

1. Power-manage networked computers 2. Specify ENERGY STAR for all office equipment

purchases 3. Computer peripherals & misc. plug load 4. Data centers

Page 33: IT Energy Savings for Non-Techies - State Electronics Challenge

33

Why are data centers energy hogs?

33

• Industrial Light & Magic deployed 84 blade servers/rack

• Just 1 rack… – Uses 28 kW – Requires 8 tons of cooling per rack

vs.

Heat equivalent to 4 Weber Spirit gas grills

280 burgers/hour!

Page 34: IT Energy Savings for Non-Techies - State Electronics Challenge

34

Data center energy savings: 3 areas of opportunity

1. IT equipment 2. Airflow management 3. HVAC adjustments

Page 35: IT Energy Savings for Non-Techies - State Electronics Challenge

35

Info available on energystar.gov/lowcarbonit

• Non-technical descriptions

• Impartial information about – Costs – Savings – Implementation

considerations

Top 12 Data Center Opportunities

1. Virtualization of Servers 2. Decommissioning of Unused

Servers 3. Consolidation of Lightly Utilized

Servers 4. Data Storage Opportunities 5. Efficient Equipment Purchase 6. Hot Aisle/Cold Aisle Arrangement 7. Containment/Enclosures 8. Variable Speed Drives 9. Housekeeping: Blanking Panels,

Cabling and Gaps 10. Server Inlet Temperature and

Humidity Adjustments 11. Air Side Economizer 12. Water Side Economizer

35

Page 36: IT Energy Savings for Non-Techies - State Electronics Challenge

36

4 Steps For Getting Everyone on Board

1. Schedule a facility walk-thru to look for potential savings opportunities – For computers, review current settings:

• Are sleep features enabled on monitors? Computers? • Do users leave PCs on at night? • Roughly how many total computers & monitors?

2. Counter technical concerns/questions with… – “You might be right: why don’t we ask an expert?” – Schedule a (free) conference call with our vendor-neutral technical advisors

3. Estimate project ROI – Estimate savings at www.energystar.gov/lowcarbonit – Contact your utility and ask about incentive programs – Emphasize increased reliability and security as side benefits

4. Build a coalition for change – Share opportunities with friends in Finance, Facilities

Page 37: IT Energy Savings for Non-Techies - State Electronics Challenge

37

Why do IT energy efficiency projects run out of steam?

Page 38: IT Energy Savings for Non-Techies - State Electronics Challenge

38

Page 39: IT Energy Savings for Non-Techies - State Electronics Challenge

39

…and what to do about it

1. Schedule a facility walk-thru to look for potential savings opportunities – For computers, review current settings:

• Are sleep features enabled on monitors? Computers? • Do users leave PCs on at night? • Roughly how many total computers & monitors?

2. Counter technical concerns/questions with… – “You might be right: why don’t we ask an expert?” – Schedule a (free) conference call with our vendor-neutral technical advisors

3. Estimate project ROI – Estimate savings at www.energystar.gov/lowcarbonit – Contact your utility and ask about incentive programs – Emphasize increased reliability and security as side benefits

4. Build a coalition for change – Share opportunities with friends in Finance, Facilities

You need an IT expert on your team. Now you have one!

Page 40: IT Energy Savings for Non-Techies - State Electronics Challenge

40

Free services to help you overcome barriers to savings

• Vendor-neutral technical consultations for saving energy – Power managing networked computers – Data centers – Misc. IT & plug load

• Software solutions for CPM • Savings estimates • Power metering studies • Public recognition

Page 41: IT Energy Savings for Non-Techies - State Electronics Challenge

41

Contact information

• Additional information at: www.energystar.gov/lowcarbonit

• Contacts: – Mike Walker, Beacon Consultants Network Inc.

(EPA Technical Support Contractor): 617-921-8445, [email protected]

– Steve Ryan, US EPA ENERGY STAR Program Manager: 202-343-9123, [email protected]