Datasheet International Headquarters Building 2, No. 28 of the Shangdi 6th Street, Haidian District,Beijing. 100085, China Tel: +86 10 8288 3305 Fax: +86 10 8288 3056 www.raisecom.com U.S.A. Headquarters 19337 US 19 North, Suite 306 Clearwater, Florida. 33764. USA. Tel: +1 888 816 4808 Fax: +1 727 547 9124 Email: [email protected]Raisecom Technology Co., Ltd. Copyright@1999-2013 All rights reserved Technical information is subjected to change without notice ISCOM RAX 711-C | Essential Demarcation Device Product Overview ISCOM RAX 711-C has a smaller size and more reliable power supply, which extend your network across carrier facilities as a 10G External Network to Network Interface (ENNI) or as a Carrier-grade Ethernet Demarcation Device (EDD), which enables CE2.0 compliant EPL, EVPL, EP-LAN, EVP-LAN and E-Access services that are widely deployed for business connections, mobile backhaul and cloud scenarios. ISCOM RAX 711-C provides an industry standard way to quickly and seamlessly connect enterprise networks with carrier Ethernet facilities, ensuring faster rollout and advanced visibility across virtualized network connections With the auto-provisioning functions and tool-kit, the 711 series greatly reduces the complexity and costs for large-scale deployment or upgrade. Service verification and turn-up can be also done remotely and efficiently with Y.1564 test sets embedded with ISCOM RAX711-C. In compliance with the latest OAM standards including IEEE 802.3ah, IEEE 802.1ag and ITU-T Y.1731, the series allows cost-effective delivery of committed SLA end-to-end or end-to-core. KPIs including throughput, jitter, delay, packet loss and availability can be performed, reported and visualized on a per service basis. ISCOM RAX711-C is defined as a universal network terminal suitable for most last mile access applications. It ensures ultra-low delay and jitter for mission-critical services with hardware-based SLA performances. ISCOMRAX711-C supports SyncE or clock and time synchronizations, which greatly extend the backhaul bandwidth at an affordable price in comparison with traditional T1/E1 or GPS-based synchronization while retaining reliable connectivity and excellent management attributes. Highlights Creation, identification and isolation of CE2.0-compliant service end-to-end or end-to-core Zero-touch Auto Provisioning ideal for large-scale deployment & upgrade Service turn-up verification based on embedded Y.1564 real-traffic simulation test suite Stable and reliable network assurance with real-time monitoring and multipoint visualized SLA parameters Low latency and low jitter for delivery of high performance services Comprehensive OAM solutions based on 802.3ah, 802.1ag and Y.1731 for OPEX reduction Carrier-class EDD with supports of SyncE for mobile backhaul applications Specifications NNI: 2 x 10GE SFP+ interfaces (10GE SFP+ & 1000BASE-X SFP support) UNI: 2 x 10GE SFP+ interfaces (10GE SFP+ & 1000BASE-X SFP support) SNMP interface: 1 x RJ45 Console interface: 1 x RJ45 Indicators: Power Supply(flashing) NNI & UNI Port: LNK/ACT SYS indicator: Indicate System status MGT indicator: Auto-Provisioning Dimensions: 220(L), 180(W), 44.45(H) mm³ Indoor temperature: 0 to 50⁰C ISCOM RAX 711-C
3
Embed
ISCOM RAX 711-C Essential Demarcation Device - raisecom…€¦ · Datasheet International Headquarters Building 2, No. 28 of the Shangdi 6th Street, Haidian District,Beijing. 100085,
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Datasheet
International Headquarters Building 2, No. 28 of the Shangdi 6th Street, Haidian District,Beijing. 100085, China Tel: +86 10 8288 3305 Fax: +86 10 8288 3056 www.raisecom.com
U.S.A. Headquarters 19337 US 19 North, Suite 306 Clearwater, Florida. 33764. USA. Tel: +1 888 816 4808 Fax: +1 727 547 9124 Email: [email protected]
Raisecom Technology Co., Ltd. Copyright@1999-2013 All rights reserved Technical information is subjected to change without notice
ISCOM RAX 711-C | Essential Demarcation Device
Product Overview
ISCOM RAX 711-C has a smaller size and more reliable power supply, which extend your network across carrier
facilities as a 10G External Network to Network Interface (ENNI) or as a Carrier-grade Ethernet Demarcation
Device (EDD), which enables CE2.0 compliant EPL, EVPL, EP-LAN, EVP-LAN and E-Access services that are widely
deployed for business connections, mobile backhaul and cloud scenarios.
ISCOM RAX 711-C provides an industry standard way to quickly and seamlessly connect enterprise networks with
carrier Ethernet facilities, ensuring faster rollout and advanced visibility across virtualized network connections With the auto-provisioning functions and tool-kit, the 711 series greatly reduces the complexity and costs for
large-scale deployment or upgrade. Service verification and turn-up can be also done remotely and efficiently
with Y.1564 test sets embedded with ISCOM RAX711-C. In compliance with the latest OAM standards including
IEEE 802.3ah, IEEE 802.1ag and ITU-T Y.1731, the series allows cost-effective delivery of committed SLA
end-to-end or end-to-core. KPIs including throughput, jitter, delay, packet loss and availability can be performed,
reported and visualized on a per service basis.
ISCOM RAX711-C is defined as a universal network terminal suitable for most last mile access applications. It
ensures ultra-low delay and jitter for mission-critical services with hardware-based SLA performances.
ISCOMRAX711-C supports SyncE or clock and time synchronizations, which greatly extend the backhaul
bandwidth at an affordable price in comparison with traditional T1/E1 or GPS-based synchronization while
retaining reliable connectivity and excellent management attributes.
Highlights
Creation, identification and isolation of CE2.0-compliant
service end-to-end or end-to-core
Zero-touch Auto Provisioning ideal for large-scale deployment
& upgrade
Service turn-up verification based on embedded Y.1564
real-traffic simulation test suite
Stable and reliable network assurance with real-time
monitoring and multipoint visualized SLA parameters
Low latency and low jitter for delivery of high performance
services
Comprehensive OAM solutions based on 802.3ah, 802.1ag and
Y.1731 for OPEX reduction
Carrier-class EDD with supports of SyncE for mobile backhaul
applications
Specifications
NNI: 2 x 10GE SFP+ interfaces
(10GE SFP+ & 1000BASE-X SFP
support)
UNI: 2 x 10GE SFP+ interfaces
(10GE SFP+ & 1000BASE-X SFP
support)
SNMP interface: 1 x RJ45
Console interface: 1 x RJ45
Indicators: Power Supply(flashing)
NNI & UNI Port: LNK/ACT
SYS indicator: Indicate System status
MGT indicator: Auto-Provisioning
Dimensions: 220(L), 180(W), 44.45(H) mm³ Indoor temperature: 0 to 50⁰C
ISCOM RAX 711-C
Datasheet
International Headquarters Building 2, No. 28 of the Shangdi 6th Street, Haidian District,Beijing. 100085, China Tel: +86 10 8288 3305 Fax: +86 10 8288 3056 www.raisecom.com
U.S.A. Headquarters 19337 US 19 North, Suite 306 Clearwater, Florida. 33764. USA. Tel: +1 888 816 4808 Fax: +1 727 547 9124 Email: [email protected]
Raisecom Technology Co., Ltd. Copyright@1999-2013 All rights reserved Technical information is subjected to change without notice
Eco-system warranty with low power consumption design Humidity: 5 to 95%, non-condensing
Lightning proof: 6kV/AC, 2kV/DC
AC&DC dual-power for ISCOM RAX711-C
Max power consumption: 26 W
Access Capacity
MTU:12,288 byte (default 1,526 byte)
Switching buffer size: 16Mbit
Synchronization
ITU-T G.8262 Synchronous Ethernet
E1 mode (120 Ohm): -2Mhz or 2M BITS
T1 mode (100 Ohm): -1.5Mhz or 1.5M BITS
Support sync status message
Ethernet
Up to 32k MAC
Support VLANXC
Support 4,094VLANs (C-tag), stacked VLANs (QinQ,
S-tag), VLAN mapping and 1:1 inner/outer VLAN
translation
Recommended 32 Ethernet virtual circuits (EVC)
per network interface device (NID)1
Layer 2 loopback on single and multiple flows
Interface protection, port monitoring
Layer 2 control protocol (L2CP) handling
IP Services
ARP
DHCP client, snooping, option 82
IPv4, IPv6
Static routing
IPv6 routing
Traffic Management
Service classification per port/VLAN/CoS(DSCP)
Support SP, WRR and SP+WRR scheduling modes,
and up to 8 queues per port
MEF-compliant 3-color policing with color-aware
and color-blind mode
Bandwidth throttling per port/VLAN/CoS(DSCP),
CIR/EIR per flow
Support hierarchical bandwidth profile in the
ingress direction
Traffic shaping for both UNI and NNI
Security
Secure MAC address
ACL based on VLAN, CoS, MAC, EtherType,
IPv4(Optional: Source IP, Destination IP, IP Protocol,
Source Port number and Destination port number
TOS/DSCP), IPv6, or user-define combinations
RADIUS, TACACS+
Storm control (broadcast, multicast, DLF)
Reliability
Link aggregation group (LAG) –four load balancing
modes based on source/destination IP and/or
MAC
Interface backup
ITU-T G.8031 Ethernet link protection switching
(ELPS) and G.8032 Ethernet ring protection
switching (ERPS) with the automatic protection
switchover time less than 50ms
Port/VLAN-based Ethernet local loop detection
Fault propagation
AC&DC dual-feed power supplies
Ethernet OAM
IEEE 802.3ah EFM-OAM link management
IEEE 802.1ag connectivity fault management (CFM)
with 3.3ms CCM resolution
ITU-T Y.1731 performance monitoring (PM)
Datasheet
International Headquarters Building 2, No. 28 of the Shangdi 6th Street, Haidian District,Beijing. 100085, China Tel: +86 10 8288 3305 Fax: +86 10 8288 3056 www.raisecom.com
U.S.A. Headquarters 19337 US 19 North, Suite 306 Clearwater, Florida. 33764. USA. Tel: +1 888 816 4808 Fax: +1 727 547 9124 Email: [email protected]
Raisecom Technology Co., Ltd. Copyright@1999-2013 All rights reserved Technical information is subjected to change without notice
Hardware-based frame delay (FD) measurement
ITU-T Y.1564 service activation test, up to 8 flows
simulation
Multipoint SLA KPIs per port or EVC, which include