Top Banner

of 20

IS800-6Tens_140

Apr 05, 2018

Download

Documents

Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
  • 7/31/2019 IS800-6Tens_140

    1/20

    TENSION MEMBERS

  • 7/31/2019 IS800-6Tens_140

    2/20

    Dr S R Satish Kumar IIT Madras 2

    DESIGN OF TENSION MEMBERS

    Introduction

    Behaviour of Tension Members

    Plates Under Tension

    Threaded Rods

    Angles Under Tension

    Code Provisions

    Summary

  • 7/31/2019 IS800-6Tens_140

    3/20

    Dr S R Satish Kumar IIT Madras 3

    Tension Members in Buildings

    suspenders

    (b) Suspended Building

    tie (a) Roof Truss

    rafter

    (c) Roof Purlin System

    purlin

    Sag rod

    Top chord

    (d) Braced frame

  • 7/31/2019 IS800-6Tens_140

    4/20

    Dr S R Satish Kumar IIT Madras 4

    INTRODUCTION

    Characteristics

    Members Experience

    Axial force

    Stretching Uniform stress over the cross section

    Very Efficient Member

    Strength governed by the material strength Bolt holes affect the strength

  • 7/31/2019 IS800-6Tens_140

    5/20

    Dr S R Satish Kumar IIT Madras 5

    INTRODUCTION

    Built up sections

    Angle Double AngleChannel

    Rod Cable

    Cross Sections Used for Tension Members

  • 7/31/2019 IS800-6Tens_140

    6/20

  • 7/31/2019 IS800-6Tens_140

    7/20

    Dr S R Satish Kumar IIT Madras 7

    BEHAVIOUR IN TENSION

    Plates with a Hole

    (a) Elastic (b) Elasto-Plastic (c) Ultimate

    uy

  • 7/31/2019 IS800-6Tens_140

    8/20

    Dr S R Satish Kumar IIT Madras 8

    BEHAVIOUR IN TENSION

    Plates with Holes (Cl 6.3)

    (b)(a)

    (c)

    P = pitch

    g = gauge

    1

    1 4p

    g2

    3

    bd

    Case a: Net Area: = t (b - 2*d)

    Case b: Net Area: = t (b

    d)

    Case c: t (b - 2*d)

  • 7/31/2019 IS800-6Tens_140

    9/20

    Dr S R Satish Kumar IIT Madras 9

    BEHAVIOUR IN TENSION

    Plates with Holes

    An = [ b n d + (p2 / 4 g)]t

  • 7/31/2019 IS800-6Tens_140

    10/20

    Dr S R Satish Kumar IIT Madras 10

    BEHAVIOUR IN TENSION

    ANGLES Eccentrically Loaded Through Gussets

    Gusset plate

  • 7/31/2019 IS800-6Tens_140

    11/20

    Dr S R Satish Kumar IIT Madras 11

    Revised IS 800:2007

    SECTION 6 DESIGN OF TENSION MEMBERS

    6.1 Tension Members

    6.2 Design Strength due to Yielding of Gross Section

    6.3 Design Strength due to Rupture of Critical Section

    6.3.1 Plates

    6.3.2 Threaded Rods

    6.3.3 Single Angles

    6.3.4 Other Sections

    6.4 Design Strength due to Block Shear

    6.4.1 Plates

    6.4.2 Angles

  • 7/31/2019 IS800-6Tens_140

    12/20

    Dr S R Satish Kumar IIT Madras 12

    6.1 Tension Members

    The factored design tension T, in the members T < Td

    6.2 Design Strength due to Yielding of Gross Section

    The design strength of members under axial tension Tdg, Tdg= fyAg / m0

    mo = 1.1

    6.3 Design Strength due to Rupture of Critical Section

    6.3.1 Plates The design strength in tension of a plate, Tdn,

    Tdn=0.9 fuAn/ m1 m1 = 1.25

    An = Contt

    g

    pndb

    i i

    ih

    4

    2

    Revised IS 800:2007 CODAL PROVISIONS

  • 7/31/2019 IS800-6Tens_140

    13/20

    Dr S R Satish Kumar IIT Madras 13

    6.3.2 Threaded Rods

    The design strength of threaded rods in tension, Tdn,

    Tdn=0.9 fuAn/m1

    Ultimateelastic elastic -Plastic

    droot

    dgross

    f

  • 7/31/2019 IS800-6Tens_140

    14/20

    Dr S R Satish Kumar IIT Madras 14

    6.3.3SingleAnglesThe design strength, Tdn, as governed

    by tearing

    Tdn =0.9fuAnc / m1 + Ago fy/ m0

    =1.4 0.076(w/t)(fu/fy)(bs/L ) [1.4-0.52(bs/L)]

    Alternatively, the tearing strength of net section may be

    taken as

    Tdn = An fu / m

    Revised IS 800:2007 CODAL PROVISIONS

  • 7/31/2019 IS800-6Tens_140

    15/20

    Dr S R Satish Kumar IIT Madras 15

    Fig. 6.2 Angles with end connections

    bs=w

    ww

    w1

    bs=w+w1

    Revised IS 800:2007 CODAL PROVISIONS

  • 7/31/2019 IS800-6Tens_140

    16/20

    Dr S R Satish Kumar IIT Madras 16

    6.4 Design Strength due to Block Shear

    6.4.1 PlatesThe block shear strength, Tdb, of connection shall be taken as the

    smaller of

    Tdb= ( Avg fy/( 3 m0) +fu Atn / m1 )

    or

    Tdb= ( fuAvn/( 3 m1) + fyAtg/ m0)

    Fig 6.2 Block Shear Failure of Plates

    12

    43

    1 2

    3

    Fig 6.3 Block Shear Failure of Angles

    4

    Revised IS 800:2007 CODAL PROVISIONS

  • 7/31/2019 IS800-6Tens_140

    17/20

  • 7/31/2019 IS800-6Tens_140

    18/20

    Dr S R Satish Kumar IIT Madras 18

    DESIGN OF TENSION MEMBERS

    Stiffness RequirementsDesigned for compression under

    stress reversal /r < 250

    Not designed for compression under

    stress reversal /r < 350

    Members under tension only /r < 400

  • 7/31/2019 IS800-6Tens_140

    19/20

    Dr S R Satish Kumar IIT Madras 19

    DESIGN OF TENSION MEMBERS

    Summary

    Efficient load carrying members

    Efficiency may reduce due to

    bolt holes

    shear lag

    block shear

  • 7/31/2019 IS800-6Tens_140

    20/20

    Dr S R Satish Kumar IIT Madras 20

    www.steel-insdag.org

    Dr S R Satish KumarAsso. Professor & Head,

    Structural Engineering Laboratory,

    Dept. of Civil Engineering,IIT Madras, Chennai 600 [email protected]

    http://www.steel-insdag.org/mailto:[email protected]:[email protected]://www.steel-insdag.org/http://www.steel-insdag.org/http://www.steel-insdag.org/