Page 1: Is the HUMVEE Powered Sufficiently? Operation Charge 10/5/06.

Is the HUMVEE Is the HUMVEE Powered Sufficiently?Powered Sufficiently?

Operation Charge Operation Charge

10/5/0610/5/06

Page 2: Is the HUMVEE Powered Sufficiently? Operation Charge 10/5/06.

PurposePurpose

To model power usage of the To model power usage of the HUMVEE.HUMVEE.

To identify power losses.To identify power losses. To propose alterations to meet final To propose alterations to meet final

goals.goals.

Page 3: Is the HUMVEE Powered Sufficiently? Operation Charge 10/5/06.

Gear RadioGear Radio

Three different gear ratios were Three different gear ratios were chosen for comparisonchosen for comparison• 19:119:1• 15:115:1• 10:110:1

This gear ratio includes the gear This gear ratio includes the gear reducer, gear differential, and portal reducer, gear differential, and portal axelaxel

Page 4: Is the HUMVEE Powered Sufficiently? Operation Charge 10/5/06.

Possible SpeedsPossible SpeedsHUMVEE MPH

0

20

40

60

80

100

120

0 2000 4000 6000 8000 10000 12000

AC Propulsion RPM

HU

MV

EE

MP

H

HUMVEE MPH 19:1

HUMVEE MPH 15:1

HUMVEE MPH 10:1

Page 5: Is the HUMVEE Powered Sufficiently? Operation Charge 10/5/06.

Developing Power ModelDeveloping Power Model

Power=Vi[Cr*Mg*cos(Θ)+Mg*sin(Θ)+.5*ρair*Cd*Af*Vi2]

Vi=Velocity

Cf=Rolling Resistance=.01

Cd=Coeff of drag=.446

ρair=1.2kg/m^3

Page 6: Is the HUMVEE Powered Sufficiently? Operation Charge 10/5/06.

Required Power to Move HUMVEERequired Power to Move HUMVEEPower for 0 slope

0

20

40

60

80

100

120

0 20 40 60 80 100 120

HUMVEE MPH

Po

wer

(K

W)

Pow er KW Required 19:1

Pow er KW Required 15:1

Pow er KW Required 10:1

Page 7: Is the HUMVEE Powered Sufficiently? Operation Charge 10/5/06.

Torque RequirementsTorque Requirements

Required Torque Curve 0% Grade

0

500

1000

1500

2000

2500

3000

3500

0 10 20 30 40 50 60 70 80 90 100

HUMVEE MPH

To

rqu

e (N

m)

Tire Torque 19:1 (Nm)

Tire Torque 15:1 (Nm)

Tire Torque 10:1 (Nm)

Torque Nm Reguired 19:1

Torque Nm Reguired 15:1

Torque Nm Reguired 10:1

Page 8: Is the HUMVEE Powered Sufficiently? Operation Charge 10/5/06.

Power Required to move HUMVEE Power Required to move HUMVEE in with efficiencies. (0% Upgrade)in with efficiencies. (0% Upgrade)

Page 9: Is the HUMVEE Powered Sufficiently? Operation Charge 10/5/06.

Torque RequirementsTorque RequirementsRequired Torque Curve 6% Grade

0

500

1000

1500

2000

2500

3000

3500

0 10 20 30 40 50 60 70 80 90 100

HUMVEE MPH

To

rqu

e (N

m)

Tire Torque 19:1 (Nm)

Tire Torque 15:1 (Nm)

Tire Torque 10:1 (Nm)

Torque Nm Reguired 19:1

Torque Nm Reguired 15:1

Torque Nm Reguired 10:1

Page 10: Is the HUMVEE Powered Sufficiently? Operation Charge 10/5/06.

Power Required to move HUMVEE Power Required to move HUMVEE in with efficiencies. (6% Upgrade)in with efficiencies. (6% Upgrade)

Page 11: Is the HUMVEE Powered Sufficiently? Operation Charge 10/5/06.

Torque RequirementsTorque RequirementsRequired Torque Curve 10% Grade

0

500

1000

1500

2000

2500

3000

3500

0 10 20 30 40 50 60 70 80 90 100

HUMVEE MPH

To

rqu

e (N

m)

Tire Torque 19:1 (Nm)

Tire Torque 15:1 (Nm)

Tire Torque 10:1 (Nm)

Torque Nm Reguired 19:1

Torque Nm Reguired 15:1

Torque Nm Reguired 10:1

Page 12: Is the HUMVEE Powered Sufficiently? Operation Charge 10/5/06.

Torque RequirementsTorque RequirementsRequired Torque Curve 15% Grade

0

500

1000

1500

2000

2500

3000

3500

0 10 20 30 40 50 60 70 80 90 100

HUMVEE MPH

To

rqu

e (N

m)

Tire Torque 19:1 (Nm)

Tire Torque 15:1 (Nm)

Tire Torque 10:1 (Nm)

Torque Nm Reguired 19:1

Torque Nm Reguired 15:1

Torque Nm Reguired 10:1

Page 13: Is the HUMVEE Powered Sufficiently? Operation Charge 10/5/06.

Power Required to move HUMVEE Power Required to move HUMVEE in with efficiencies.(15% Upgrade)in with efficiencies.(15% Upgrade)

Page 14: Is the HUMVEE Powered Sufficiently? Operation Charge 10/5/06.

Torque RequirementsTorque RequirementsRequired Torque Curve 11.5% Grade

0

500

1000

1500

2000

2500

3000

3500

0 10 20 30 40 50 60 70 80 90 100

HUMVEE MPH

To

rqu

e (N

m)

Tire Torque 19:1 (Nm)

Tire Torque 15:1 (Nm)

Tire Torque 10:1 (Nm)

Torque Nm Reguired 19:1

Torque Nm Reguired 15:1

Torque Nm Reguired 10:1