Top Banner
www.inl.gov 2010 RELAP5 International Users Seminar September 20-23, 2010 West Yellowstone, Montana IRUG Member Meeting
20

IRUG Member Meeting

Jan 09, 2016

Download

Documents

Sen

IRUG Member Meeting. 2010 RELAP5 International Users Seminar September 20-23, 2010 West Yellowstone, Montana. Agenda. Acceptance of August 2009 meeting minutes Status of IRUG Membership Old Business Status of User Problems Selected User Problem Descriptions New Business - PowerPoint PPT Presentation
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: IRUG Member Meeting

www.inl.gov

2010 RELAP5 International Users SeminarSeptember 20-23, 2010West Yellowstone, Montana

IRUG Member Meeting

Page 2: IRUG Member Meeting

Agenda

• Acceptance of August 2009 meeting minutes

• Status of IRUG Membership

• Old Business– Status of User Problems– Selected User Problem Descriptions

• New Business– Schedule for code release– Other items

• Election of New Chair

• Adjourn

• Status

Page 3: IRUG Member Meeting

IRUG Member Status

Members:• Bechtel Marine Propulsion

Corporation (KAPL/Bettis)• NRI-Rez• Areva NP• General Dynamics Electric

Boat• INSS• Rolls-Royce• Mitsubishi Heavy Industries

Participants:• Arizona Public Service• Newport News• Nuclear Engineering LTD

(Japan)• Nuclear Engineering LTD• JNES• Oak Ridge National Lab• ILD Power• KIT

• Institute of Nuclear Energy Research (China)

Page 4: IRUG Member Meeting

Current University License Holders

• Oregon State Univ.• Texas A&M Univ.• U. of Catalonia• Univ of Pisa• U. of Michigan• Idaho State Univ.• Univ. of Tennessee

• Univ of Massachusetts• Ohio State• U. Of Illinois-UC• Florida International

• Universidade Federal de Minas Gerais

• Univ Of Wisconsin• UC Berkeley

Page 5: IRUG Member Meeting

National Laboratories

• ORNL

• LANL

• ANL

• LLNL

Page 6: IRUG Member Meeting

User Problem HistoryJuly 2009 - July 2010

176 reported/worked-on

Resolved: Work has been completed on user problem, update has been submitted, and update is in latest developmental version

Solved: Work has been completed on user problem, update has been submitted, but update is not in latest developmental version

In-Work: Work on user problem is currently being carried out

On-Hold: Work has not begun on user problem, or work was began on user problem but work is now stopped on user problem

In-Work (53)

Solved (0)

On-Hold (34)

Resolved (89)

Page 7: IRUG Member Meeting

Selected User Problems

Page 8: IRUG Member Meeting

Problem 00041

• Symptom: Many nodal kinetics input models require more memory than code has available; this necessitates updating code to increase size of FAST array. Problem was found in version 1.1 (cf02); affects all earlier versions and some later versions.

• Root Cause: Maximum size of FAST array was a fixed number.

• Resolution: Resolved. During FORTRAN 95 conversion, allocates were used after reading in input model. At this point, the code knows the size an array needs to be for a given input model. Update appeared in version 2.9.2.

Page 9: IRUG Member Meeting

Problem 06035

• Symptom: System calculation using 3D hydro (multid) components fails in input processing in BPLU solver reordering. Calculation runs with MA18 solver. Problem was found in version 2.4.1; affects all earlier versions and some later versions.

• Root Cause: BPLU solver arrays are dimensioned too small.

• Resolution: Resolved. During FORTRAN 95 conversion, BPLU solver arrays are now allocated. Update appeared in version 2.9.4.

Page 10: IRUG Member Meeting

Problem 10016

• Symptom: Simple ATR heat transfer problem fails on second problem of stacked job when heat conduction enclosure model is used. Both problems run when enclosure model is commented out. Error message says number of conduction sets does not agree with number requested. This was found in version 2.9.4; this affects some earlier RELAP5-3D versions.

• Root Cause: Variable ‘l3a(1)’ in subroutine RRADHT was not reset properly when running stacked cases.

• Resolution: Resolved. Added line ‘l3a(1) = 60000000’ at beginning of subroutine RRADHT. Update appeared in version 2.9.5.

Page 11: IRUG Member Meeting

Problem 10024

• Symptom: HTGR calculation fails with multiple thermodynamic property failures when axial conduction model is used together with implicit heat transfer coupling. Failures do not occur when explicit coupling is used or when implicit coupling is used without axial conduction. This was found in version 2.9.4; this affects some earlier RELAP5-3D versions.

• Root Cause: Variables ‘htc2x’ and ‘htb2x’ were set incorrectly in subroutine HT2TDP.

• Status: Resolved. Fixed subroutine HT2TDP coding. Update appeared in version 2.9.5.

Page 12: IRUG Member Meeting

Problem 10031

• Symptom: In comparing Groeneveld et al. CHF table in code (subroutine CHFTAB) to 1986 paper, errors were found. Errors go back to RELAP5/MOD3.

• Root Cause: Errors introduced when reading numbers from paper and typing them into code.

• Status: Resolved. Fixed subroutine CHFTAB by electronically reading pdf file numbers (from paper) and converting them into ascii numbers. There were 41 errors; 15 potentially significant (differences of 1.3% and greater); rest all having differences less than 0.5%. Update appeared in version 2.9.5.

Page 13: IRUG Member Meeting

Problem 10041

• Symptom: In running system problem, an error regarding variable ‘conv’ was found in subroutine RTMDV; coding is correct in subroutine RTMDJ. Error was found in version 2.4.1. Error goes back to RELAP5/MOD1.

• Root Cause: An ‘if test’ on variable ‘conv’ was missing in subroutine RTMDV.

• Status: Resolved. Fixed subroutine RTMDV to add ‘if test’ on variable ‘conv’ as is done in subroutine RTMDJ. Update appeared in version 2.9.5.

Page 14: IRUG Member Meeting

Problem 10043

• Symptom: Code gave same results with and without Card 1 Option 23, which turns on Godunov scheme for boron tracking. Error was found in version 2.4.1. Fixing inverted junction table errors in subroutines STGODU and BRNTRN in RELAP5/MOD3.2.1.2, that were fixed in version 2.4.1, shows the same bad result.

• Root Cause: Unknown.

• Status: In-Work. Coding is under investigation. Code manual implies Godunov scheme gives better results than default upwind difference scheme, however AP600 experience found Godunov scheme is not reliable at steady state; thus it was not chosen as default scheme. Manual was modified.

Page 15: IRUG Member Meeting

Problem 10044

• Symptom: Code gave severe oscillations for the offtake model for larger small breaks. Subroutine HZFLOW calculates mass flux based on max of volume mass flux and junction mass flux. Subroutine PHANTV calculates mass flux based on volume mass flux. For a large enough break, junction mass flux can exceed volume mass flux; this can lead to inconsistent interpolations. Error was found in version 2.4.1. Error was introduced in RELAP5/MOD3.

• Root Cause: Inconsistent interpolations.

• Status: In-Work. An update has been developed, and it is currently being tested.

Page 16: IRUG Member Meeting

Next Code Version Release

• Last Released IRUG Version was 2.4.3• FORTRAN 95 Version 3.0 Ready for Beta version

release to IRUG Members• Receipt of the Code Will Require a Beta Version

License• Beta Version Will be Executable With Approximately a

Three Month License File• Large Number of New Features and Capability Have

Been Added in Addition to the FORTRAN 95 Programming Language Change

Page 17: IRUG Member Meeting

RELAP5-3D CHANGES SINCE VERSION 2.4.3

• RELAP5-3D Changes/New Features Since Version 2.4.3

• New Features– FORTRAN 95– Restructuring with FOR_STRUCT– Developmental Assessment– Improved Time Step Control– Improved Nodal Kinetics– Institutionalized Card 1, Option 3 (Consistent Sound Speed

Calculation between Volumes and Junctions when Noncondensables are Present)

Page 18: IRUG Member Meeting

RELAP5-3D CHANGES SINCE VERSION 2.4.3 (cont.)

– Allow Efficiency Multiplier (for Type-3 Turbine) using a Control Variable and Turbine Inlet Junction Form Loss Multiplier using a Control Variable

– Allow PVM Coupled Restart from Uncoupled Runs– Modified PVM Coupling to send any RELAP5-3D Nodal Kinetics

Variable instead of the Restricted List of Power, Zone, Heat Structure Average Temperature, etc.

– Added Card 1 Option 27 to set Theta Velocity in Outermost Ring of Rigid Body Rotation and R-theta Symmetric Problems to 1.0 m/s

– Added Card 1 Option 29 to allow more Accurate Solution to Momentum Equations for Low Flows

– Allow Fluid Interactive Capability for the Working Fluid D2O– Allow Input Options NEW and NEWATH to use all Working Fluids

Page 19: IRUG Member Meeting

RELAP5-3D CHANGES SINCE VERSION 2.4.3 (cont.)

– ANS 2005 Decay Heat Standard– Pump Head and Torque Multiplier as a Function of

Pressure and Void Fraction– CO2 Properties Improvement for Running near and

through the Critical Point– Improved Compressor Model (Allow Input Negative

Flows on Speed Tables, Allow Compressors to Run with Noncondensable Gases)– Added Command Line Argument ‘-stat’ for Run

Statistics for Developmental Assessment

Page 20: IRUG Member Meeting

RELAP5-3D CHANGES SINCE VERSION 2.4.3 (cont.)

– 2D Heat Conduction Model without Reflood– Alternate Heat Structure – Fluid Coupling Model– Linux SUSE Platform Capability– R5FORCE Windows PC Platform Capability– PVM Coupling Junction– Fluids DOWTHERM A and R134a (SUVA)– Added Card 1 Option 71 to allow Improved

Metastable Extrapolation into Superheated Liquid– Added Additional Mass Error Edits– AptPlot Capability