Ion Mobility Spectrometry Photo Ionization Detector Gas Chromatography MPS Introduction Our MPS is designed for subsequently continuous monitoring of multiple measuring points. It’s desig- ned to work as an integral part of a measuring sys- tem. It is used for online measurements. The sample pump, valves and sample lines are at ambient tem- perature. It is an ideal tool to measure components in ambient conditions from several measuring points. The design is based on blocks of 4 measurement channels each. You can combine this by up to 16 points per device. It is available in a wall mounted stainless steel case or 19" rack system which includes all valves, a flow meter and two pumps. The function of the MPS is fully automatic and con- trolled by the internal software. Features - Long-term-stability and reliability - Solid-state electronics and few moving parts - Low Maintenance Time - High Up Time - Different enclosures possible
2

Ion Mobility Spectrometry MPSiut-technologies.de/wp-content/uploads/2020/10/eng...Ion Mobility Spectrometry Photo Ionization Detector Gas Chromatography MPS Introduction Our MPS is

Jan 26, 2021

Download

Documents

dariahiddleston
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
  • Ion Mobility Spectrometry

    Photo Ionization Detector

    Gas Chromatography MPS

    Introduction

    Our MPS is designed for subsequently continuous monitoring of multiple measuring points. It’s desig-ned to work as an integral part of a measuring sys-tem.

    It is used for online measurements. The sample pump, valves and sample lines are at ambient tem-perature. It is an ideal tool to measure components in ambient conditions from several measuring points.

    The design is based on blocks of 4 measurement channels each. You can combine this by up to 16 points per device.

    It is available in a wall mounted stainless steel case or 19" rack system which includes all valves, a flow meter and two pumps.

    The function of the MPS is fully automatic and con-trolled by the internal software.

    Features

    - Long-term-stability and reliability

    - Solid-state electronics and few moving parts

    - Low Maintenance Time - High Up Time

    - Different enclosures possible

  • Ion Mobility Spectrometry

    Photo Ionization Detector

    Gas Chromatography Specifications

    Description Multipoint Sampling System for Gas analyzers Sample Points chooseable between 4,8, 12 and 16 points per deviceSolid-state electronics and few moving parts

    Operating ambient Temperature

    OutputMaintenance Rate

    19" Housing: 15 °C - 30 °C (+59 °F - 86 °F)NEMA 4X Housing: -40 °C - 50 °C (-40 °F - 122 °F)

    Integrated graph. display, 1 RS 232, LAN/W-LAN (optional), Digital I/O1x yearly service

    Dimensions

    Weight

    19" Housing: 483 (W) x 138 (H) x 420 mm (D) (19.1 x 5.4 x 16.5 inch)NEMA 4X Housing: 500 (W) x 500 (H) x 210 mm (D) (19.7 x 19.7 x 8.3 inch)

    19" Housing: 10 kg (22,1 lbs)NEMA 4X Housing: 18 kg (39,7 lbs)

    Power supplyAvg. power consump.Peak power consump.

    230 (115) VAC; 3 (5) A; 50 (60) Hz19" Housing: 12 W NEMA 4X Housing: 12 W19" Housing: 50 W NEMA 4X Housing: 50 W

    MPS

    Operating Specification

    Analyzer Physical Specification

    Utility Requirements

    IUT Technologies GmbHVolmerstrasse 7 BD-12489 BerlinGermanyphone: +49 (0)30 20 14 33 00 0fax: +49 (0)30 20 14 33 00 9e-mail: [email protected]

    Seite1Seite2