Introduction to B-tek Introduction to B-tek “Digital” load cell “Digital” load cell Shows complete assembly as in the Shows complete assembly as in the “Centurion” Truck Scale. “Centurion” Truck Scale. Has a 5 year Has a 5 year “end wall to end wall” “end wall to end wall” warranty, which includes lightning warranty, which includes lightning strikes. strikes. Shows how easily the system can be Shows how easily the system can be serviced serviced
14

Introduction to B-tek “Digital” load cell

Dec 30, 2015

Download

Documents

abdul-burton

Introduction to B-tek “Digital” load cell. Shows complete assembly as in the “Centurion” Truck Scale. Has a 5 year “end wall to end wall” warranty, which includes lightning strikes. Shows how easily the system can be serviced. Base Plate. Galvanized Retainer Plate. - PowerPoint PPT Presentation
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: Introduction to B-tek  “Digital” load cell

Introduction to B-tek Introduction to B-tek “Digital” load cell“Digital” load cell

Shows complete assembly as in the Shows complete assembly as in the “Centurion” Truck Scale.“Centurion” Truck Scale.

Has a 5 year Has a 5 year “end wall to end wall”“end wall to end wall” warranty, which includes lightning warranty, which includes lightning strikes.strikes.

Shows how easily the system can be Shows how easily the system can be servicedserviced

Page 2: Introduction to B-tek  “Digital” load cell

Base Plate

Page 3: Introduction to B-tek  “Digital” load cell

Galvanized Retainer Plate

Checks the load cell assembly unto the load plate, galvanized to inhibit rust

Page 4: Introduction to B-tek  “Digital” load cell

Non-Metallic Insulation Disc Installed

Insulates metal base platefrom load cell receiver

Page 5: Introduction to B-tek  “Digital” load cell

Bottom Load Pin Receiver Installed

Page 6: Introduction to B-tek  “Digital” load cell

Anti-Rotation Pin Installed

Positive check to keep load cell from rotating

Page 7: Introduction to B-tek  “Digital” load cell

Load Cell Insulation Ring Installed

Page 8: Introduction to B-tek  “Digital” load cell

Stainless Steel Hermetically-Sealed Load Cell

100% digital communication to indicator

Water-proof quick disconnect

Page 9: Introduction to B-tek  “Digital” load cell

Top Load Pin Installed

Mounts into weigh bridgereceiver hole

Page 10: Introduction to B-tek  “Digital” load cell

Sealed Quick Disconnect Cable

Water proof all stainless steel with stainless sheath load cell cable and weather resistant connector cover

Page 11: Introduction to B-tek  “Digital” load cell

Water Proof Quick-Disconnect Connector Installed

Easy to change load cell if necessary

Page 12: Introduction to B-tek  “Digital” load cell

Weather Proof Connector Cover Installed

Page 13: Introduction to B-tek  “Digital” load cell

Grounding Straps Installed

All items installed gives a (5)year end wall to end wall warranty, includes lightning

Page 14: Introduction to B-tek  “Digital” load cell

Call Midwest Scale Company Call Midwest Scale Company (800)521-0857(800)521-0857