Intrinsically Safe Pressure Gauge Model AI DESCRIPTION As an in-process gauge or portable calibrator, the hand-held Model AI delivers long-lasting performance with enhanced accu- racy. Accuracy of 0.05 % coupled with an enhanced resolution, 4½-digit display makes this unit an excellent transfer standard for calibrating pressure measuring equipment. The AI is rugged and features high/low pressure capture with a field-adjustable update rate from three-to-ten times per sec- ond. These units are manufactured from stainless steel and use sensor technology which has no moving parts, requires little recalibration and has excellent overpressure tolerance. NEMA 4 construction provides EMI and RFI protection. Units of measure are field-selectable, and the unit is offered with gage, absolute, vacuum, or compound reference. The Model AIW is powered by one or two common 9 V alkaline batteries. The Model AIV is powered by an 11 Vdc to 32 Vdc power supply. The AI Digital Gauges have the following complete Factory Mu- tual Approved Classifications: Class I: Gases and vapor Class II: Combustible dust Class III: Fibers Intrinsically safe systems limit the thermal and electrical energy to the hazardous area to help prevent ignition. Division 1: present or likely to be present in normal operation Division 2: not present in normal operation Group A: Acetylene Group B: Hydrogen Group C: Acetaldehyde, Ethylene, Methyl Ether Group D: Acetone, Gasoline, Methanol, Propane Group E: Metal dust Group F: Carbon dust Group G: Grain dust FEATURES • High accuracy: 0.05 % full scale • Factory Mutual approved • Ranges to 10000 psi - gage, absolute, vacuum, or com- pound • Stainless steel construction • 4½ digit display with 0.5 in height • On/off switch • Optional handles • Optional carrying case and panel mounting ring • 9 V battery power • High/low capture and store Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
46
Embed
Intrinsically Safe Pressure Gauge - Steven EngineeringDigital Pressure Test Gauge Model AK DESCRIPTION The hand-held Model AK is an in-progress gauge or por-table calibrator and delivers
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Intrinsically Safe Pressure GaugeModel AI
DESCRIPTIONAs an in-process gauge or portable calibrator, the hand-held
Model AI delivers long-lasting performance with enhanced accu-
racy. Accuracy of 0.05 % coupled with an enhanced resolution,
4½-digit display makes this unit an excellent transfer standard
for calibrating pressure measuring equipment.
The AI is rugged and features high/low pressure capture with a
field-adjustable update rate from three-to-ten times per sec-
ond. These units are manufactured from stainless steel and use
sensor technology which has no moving parts, requires little
recalibration and has excellent overpressure tolerance. NEMA 4
construction provides EMI and RFI protection. Units of measure
are field-selectable, and the unit is offered with gage, absolute,
vacuum, or compound reference.
The Model AIW is powered by one or two common 9 V alkaline
batteries. The Model AIV is powered by an 11 Vdc to 32 Vdc
power supply.
The AI Digital Gauges have the following complete Factory Mu-
tual Approved Classifications:
Class I: Gases and vapor
Class II: Combustible dust
Class III: Fibers
Intrinsically safe systems limit the thermal and electrical energy
to the hazardous area to help prevent ignition.
Division 1: present or likely to be present in normal operation
Division 2: not present in normal operation
Group A: Acetylene
Group B: Hydrogen
Group C: Acetaldehyde, Ethylene, Methyl Ether
Group D: Acetone, Gasoline, Methanol, Propane
Group E: Metal dust
Group F: Carbon dust
Group G: Grain dust
FEATURES• Highaccuracy:0.05%fullscale
• FactoryMutualapproved
• Rangesto10000psi-gage,absolute,vacuum,orcom-
pound
• Stainlesssteelconstruction
• 4½digitdisplaywith0.5inheight
• On/offswitch
• Optionalhandles
• Optionalcarryingcaseandpanelmountingring
• 9Vbatterypower
• High/lowcaptureandstore
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Rating NEMA 4 (also provides temperature range of -18 °C to 82 °C [0 °F to 180 °F])
Power, Model AIW Oneortwo9Valkalinebatteries(in-cluded)
Power, Model AIV 11 Vdc to 32 Vdc @ 100 mA (3 ft cable included)
MECHANICAL SPECIFICATIONS
Characteristic Measure
Diameter 93,98 mm [3.7 in]
Display 4 LCD digits - 12,7 mm [0.5 in] high
Pressure port 9/16-18 UNF-2B - female straight thread with SAE spec J514 o-ring boss
Wetted parts Stainless steel
Case material Stainless steel
Low battery indication Standard
Face membrane Tactile feedback raised buttons
Calibration data Stored on memory chip
MOUNTINg DIMENSIONS AND CHARACTERISTICS
For reference only
ADDITIONAL SPECIFICATIONS
Pressure range (psi)
Maximum safe over pressure (psi)1
Incremental display steps
0 psi to 15 psi = 15
75 0.005
0 psi to 50 psi = 50
250 0.01
0 psi to 100 psi = 100
500 0.02
0 psi to 200 psi = 200
1000 0.05
0 psi to 500 psi = 500
1500 0.1
0 psi to 750 psi = 750
1500 0.2
0 psi to 1000 psi = 1K
2000 0.2
0 psi to 1500 psi = 1.5K
3000 0.5
0 psi to 2000 psi = 2K
4000 0.5
0 psi to 5000 psi = 5K
7500 1
0 psi to 7500 psi = 7.5K
12000 2
0 psi to 10000 psi = 10K
15000 2
1 Maximum safe overpressure is the pressure which the unit can experience oc-casionally without the loss of accuracy or permanent damage
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Warranty. Honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship. Honeywell’s standard product warranty applies unless agreed to otherwise by Honeywell in writing; please refer to your order acknowledgement or consult your local sales office for specific warranty details. If warranted goods are returned to Honeywell during the period of coverage, Honeywell will repair or replace, at its option, without charge those items it finds defective. The foregoing is buyer’s sole remedy and is in lieu of all warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall Honeywell be liable for consequential, special, or indirect damages.
While we provide application assistance personally, through our literature and the Honeywell web site, it is up to the customer to determine the suitability of the product in the application.
Specificationsmaychangewithoutnotice.Theinformationwesupply is believed to be accurate and reliable as of this printing. However, we assume no responsibility for its use.
FormoreinformationaboutSensingandControlproducts,visitwww.honeywell.com/sensing or call +1-815-235-6847Email inquiries to [email protected]
Failure to comply with these instructions could result in death or serious injury.
Notes
1.Thelimit/relaymodelsincludetwoLEDstatusindicatorsonfrontfaceand two form C relays (normally open, common, normally closed) that are rated at a maximum 24 Vdc/Vac at 1 A or 48 Vdc/Vac at 1/2 A.
ORDER gUIDE
W = Battery powered (9 V alkaline)*V = 11 Vdc to 32 Vdc (3 ft. cable)
* = Example
SERIESAI
AI W 200 G
POWER
PRESSURE RANGE (PSI)
REFERENCEG = Gage (std) reads zero at atmosphere *A = Absolute (opt) reads zero at vacuum (15 psi or higher)V = Vacuum (opt) scaled in In Hg (15 psi or lower)C = Compound (opt) reads both positive & negative
(vacuum) pressure
ELECTRICAL CONNECTION
Z
15 = 0-1550 = 0-50100 = 0-100200 = 0-200*
500 = 0-500750 = 0-7501K = 0-10001.5K = 0-1500
2K = 0-20005K = 0-50007.5K = 0-750010K = 0-10000
Z = No electrical connection (Model AIW - 9 V battery)*C = 3 foot cable (Model AIV)Call factory for availability of other electrical connections and cable lengths.
Each gauge has the following scaling built in for field selection:FIELD SELECTABLE STANDARD UNITS OF MEASURE
Bar = BarmBar = MillibarkPa = KilopascalsMPa = Megapascals
Ft H20 = Feet of waterIn H20 = Inches of waterIn Hg = Inches of mercurymmHg = mm of mercury
Consult factory for other units of measure not listed
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Digital Pressure Test GaugeModel AK
DESCRIPTIONThe hand-held Model AK is an in-progress gauge or por-
table calibrator and delivers long-lasting, enhanced accuracy
performance. Accuracy of 0.05 % coupled with an enhanced
resolution, 4½-digit display makes this unit an excellent transfer
standard for calibrating pressure measuring equipment.
The AK is rugged and features high/low pressure capture with
a field-adjustable update rate from three to 10 times per sec-
ond. These units are manufactured from stainless steel and use
sensor technology which has no moving parts, requires little
recalibration and has excellent overpressure tolerance. Optional
NEMA 4 rating extends the operating temperature to -18 °C to
82 °C [0 °F to 180 °F]. Units of measure are field-selectable and
the unit is offered with gage, absolute, vacuum, or compound
reference.
* with optional NEMA 4 rating
FEATURES• Highaccuracy:0.05%fullscale
• 0°Fto180°Foperatingtemperature*
• Enhancedresolution
• Stainlesssteelconstruction
• Field-selectableunitsofmeasure
• 4½digitdisplaywith0.5inheight
• Customerrecalibration
• On/Offswitch
• CEcompliant(certainmodels,consultfactory)
• NEMA4rating(optional)
• Optionalcarryingcaseandpanelmountingring
• Optionalpressureports
• NISTtraceable(optional)
• 9Vbatterypower
• High/lowcaptureandstore
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
REFERENCEG = Gage (std) reads zero at atmosphere *A = Absolute (opt) reads zero at vacuum (15 psi or higher)V = Vacuum (opt) scaled in In Hg (15 psi or lower)C = Compound (opt) reads both positive & negative
(vacuum) pressure
ELECTRICAL CONNECTIONZ = No electrical connection (Model AKW - 9 V battery)*C = 3 foot cable (Model AKV)T = ac adapter (Model AKT)
Call factory for availability of other electrical connections & cable lengths.
Z
OPTIONAL4 = NEMA 4 (Not available on AKT)
NEMA 4 option also provides temperature range of 0-180°F
4
Each gauge has the following scaling built in for field selection:FIELD SELECTABLE STANDARD UNITS OF MEASURE
Bar = BarmBar = MillibarkPa = KilopascalsMPa = Megapascals
Ft H20 = Feet of waterIn H20 = Inches of waterIn Hg = Inches of mercurymmHg = mm of mercury
Consult factory for other units of measure not listed
ORDER CODES
ADDITIONAL SPECIFICATIONS
Pressurerange(psi) Maximum safe over pressure(psi)1
Incrementaldisplaysteps
0 psi to 15 psi = 15 75 0.005
0 psi to 50 psi = 50 250 0.01
0 psi to 100 psi = 100 500 0.02
0 psi to 200 psi = 200 1000 0.05
0 psi to 500 psi = 500 1500 0.1
0 psi to 750 psi = 750 1500 0.2
0 psi to 1000 psi = 1K 2000 0.2
0 psi to 1500 psi = 1.5K 3000 0.5
0 psi to 2000 psi = 2K 4000 0.5
0 psi to 5000 psi = 5K 7500 1
0 psi to 7500 psi = 7.5K 12000 2
0 psi to 10000 psi = 10K 15000 2
1 Maximum safe overpressure is the pressure which the unit can experience oc-casionally without the loss of accuracy or permanent damage
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Warranty. Honeywellwarrantsgoodsofitsmanufactureasbeing free of defective materials and faulty workmanship. Honeywell’sstandardproductwarrantyappliesunlessagreedtootherwisebyHoneywellinwriting;pleaserefertoyourorder acknowledgement or consult your local sales office for specificwarrantydetails.IfwarrantedgoodsarereturnedtoHoneywellduringtheperiodofcoverage,Honeywellwillrepairor replace, at its option, without charge those items it finds defective. The foregoing is buyer’s sole remedy and is in lieu of all warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall Honeywell be liable for consequential, special, or indirect damages.
While we provide application assistance personally, through our literatureandtheHoneywellwebsite,itisuptothecustomertodetermine the suitability of the product in the application.
Specificationsmaychangewithoutnotice.Theinformationwesupply is believed to be accurate and reliable as of this printing. However,weassumenoresponsibilityforitsuse.
FormoreinformationaboutSensingandControlproducts,visitwww.honeywell.com/sensing or call [email protected]
6.Urefaciblafeuipitnostinvullamzzrildolestoconsentnisdelipsusci-lis nismodiamcor sustinit am eugait velestinit ut nibh elisim eugait nim iril ut del duisi.
MOUNTING DIMENSIONS AND CHARACTERISTICS
For reference only
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Model JA
DESCRIPTIONThe Series JA digital pressure test gauge with 0.1 % full scale
accuracy uses transducer technology and a stainless steel
diaphragm for high overpressure protection. The transducer
technology provides enhanced accuracy over the entire pres-
sure range. The JA has no moving parts and thus, may provide
a long life with fewer re-calibrations. The stainless steel NEMA
construction also provides EMI and RFI protection. The JA
provides high resolution with an easy to read digital display.
There are no operator errors due to interpolation of hash marks
or parallax errors.
The Model JAB provides a 4 mA to 20 mA, two-wire output.
The Model JAE provides a 0 Vdc to 5 Vdc output. The Model
JAR has two programmable limits and relays with no analog
output. The Model JAX provides a 0 Vdc to 5 Vdc output with
two programmable limits and relays for process control or alarm
indication. The Model JAW is powered by one or two common
9 V alkaline batteries. The Model JAT is powered by a 110 Vac
adapter. The Model JAV is powered by an 11 Vdc to 32 Vdc
power supply.
Each unit has a membrane face with raised buttons and tactile
feedback for setup and operation. The high, low, and clear but-
tons are easily accessible on this front membrane. Zero adjust-
ment and zero offset/tare functions are standard on each unit.
Calibration and setup parameters are stored on a memory chip
to protect from loss even when power is interrupted. Unauthor-
ized set ups and calibrations are also blocked with internal
security. Various combinations of the front panel buttons can be
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
2Honeywell•SensingandControl
Model JA
PERFORMANCE SPECIFICATIONS
Characteristic Measure
Linearity and hysteresis 0.1%fullscale(betterthantestgaugeaccuracy)
Pressure range 0 psi to 10, 20, 50, 100, 200, 500, 1000, 2000, 5000 and 10000 psi
Highandlowcapture Standard
Update speed 3 times per sec
Zero and span signal adjustment
Standard: Models JAB, JAE, JAX
ENVIRONMENTAL SPECIFICATIONS
Characteristic Measure
Temperature, operating -1 °C to 71 °C [30 °F to 160 °F]
ELECTRICAL SPECIFICATIONS
Characteristic Measure
Rating NEMA2(optionalNEMA4)
Power, Model JAW Oneortwo9Valkalinebatteries(in-cluded)
Power, Model JAT 110Vacadapter@60Hz(included)
Power, Model JAV 11Vdcto32Vdc@100mA(3ftcableincluded)
Power, Model JAB 11Vdcto32Vdc(dependingonloopresistance)@20mA
Power, Model JAE 11 Vdc to 32 Vdc @ 100 mA
Power, Model JAR 11 Vdc to 32 Vdc @ 100 mA
Power, Model JAX 11 Vdc to 32 Vdc @ 100 mA
Electrical connection 3 ft cable standard: Models JAB, JAE, JAR, JAX, JAV
2 Maximum safe overpressure is the pressure which the unit can experience oc-casionally without the loss of accuracy or permanent damage
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Warranty. Honeywellwarrantsgoodsofitsmanufactureasbeing free of defective materials and faulty workmanship. Honeywell’sstandardproductwarrantyappliesunlessagreedtootherwisebyHoneywellinwriting;pleaserefertoyourorder acknowledgement or consult your local sales office for specific warranty details. If warranted goods are returned to Honeywellduringtheperiodofcoverage,Honeywellwillrepairor replace, at its option, without charge those items it finds defective. The foregoing is buyer’s sole remedy and is in lieu of all warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall Honeywell be liable for consequential, special, or indirect damages.
While we provide application assistance personally, through our literatureandtheHoneywellwebsite,itisuptothecustomertodetermine the suitability of the product in the application.
Specifications may change without notice. The information we supply is believed to be accurate and reliable as of this printing. However,weassumenoresponsibilityforitsuse.
For more information about Sensing and Control products, visit www.honeywell.com/sensing or call +1-815-235-6847Email inquiries to [email protected]
Failure to comply with these instructions could result in death or serious injury.
ORDER gUIDE
* = ExampleZG1KWJA ( )
The following order code is used ONLY if you want this option.
4 = NEMA 4 (not available on Model JAT)
G = Gage (std) reads zero at atmosphere*A = Absolute (opt) reads zero at vacuum(15 psi or higher)
ELECTRICAL CONNECTION
PRESSURE RANGE (PSI)
Models with Output SignalB = 4 mA to 20 mA (two-wire)E = 0 Vdc to 5 VdcR = 2 programmable limits & relaysX = 0 Vdc to 5 Vdc with two limits & relays
Models with No Output SignalW = Battery powered (9 V alkaline) *T = 110 Vac adapter (included)V = 11 Vdc to 32 Vdc (3 ft. cable)
MODEL DESIGNATION
SERIESJA = High accuracy 0.1% full scale*
0-10 =100-20 =200-50 =500-100=100
REFERENCE
0-200 = 2000-500 = 5000-1000 = 1K*0-2000 = 2000
0-5000 = 5K0-10000 = 10K
This ordercode is usedONLY if you
wantNEMA 4Rating.
Z = No electrical connection (Model JAW - 9 volt battery)*C = 3 foot cableT = ac adapter (Model JAT)B = Bendix (opt) PTIH-10-6P or equal (connector sold separately)Call factory for availability of other electrical connections and cablelengths.
Bar = Bar Ft H20 = Feet of waterMBar = Millibar In H20 = Inches of waterkPa = Kilopascals In Hg = Inches of mercuryMPa = Megapascals mmHg = mm of mercuryConsult factory for other units of measure not listed
FIELD SELECTABLE STANDARD UNITS OF MEASURE
NEMA 4 CONSTRUCTION
NOTES1. The limit/relay models include two LED status indicators on front
faceandtwoformCrelays(normallyopen,common,normallyclosed)thatareratedatamaximum24Vdc/Vacat1Aor48Vdc/Vac at 1/2 A.
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Differential Digital Pressure GaugeModel JD
FEATURES• Ranges 1 psi to 10000 psi differential
• Field selectable units of measure
• 4 mA to 20 mA (two-wire) or 0 Vdc to
5 Vdc analog outputs (optional)
• Two programmable limits and relays (optional)
• High and low detection with microprocessor memory
• 4½ digit display with 0.5 in height
• Accuracy 0.2 % full scale
• Optional NEMA 4 rating
• NIST traceable
• CE compliant (certain models, consult factory)
• On/off switch with auto-off feature
DESCRIPTIONThe hand-held Model JD wet/wet differential pressure gauge de-
of 0.2 % coupled with an enhanced resolution, 4½-digit display
makes this unit an excellent transfer standard for calibrating
pressure measuring equipment.
The JD is rugged and features high/low pressure capture with an
update rate of three times per second. These units are manufac-
tured from stainless steel and use sensor technology which has
no moving parts, requires little recalibration, and has excellent
overpressure tolerance.
Each unit has a membrane face with raised buttons and tactile
feedback for setup and operation. The high, low, and clear but-
tons are easily accessible on this front membrane. Zero adjust-
ment and zero offset/tare functions are standard on each unit.
Calibration and setup parameters are stored on a memory chip
to protect from loss even when power is interrupted. Unauthor-
ized set ups and calibrations are also blocked with internal
security. Various combinations of the front panel buttons can be
de-activated.
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
2 Honeywell • Sensing and Control
Model JD
PERFORMANCE SPECIFICATIONS
Characteristic Measure
Linearity and hysteresis 0.2 % full scale (better than test gage accuracy)
NISTCERTS NIST certification (in addition to NIST statement)
* Stainless steel available
ADDITIONAL SPECIFICATIONS
Pressure range (psi)
Maximum line pressure (psi)1
Maximum safe over pressure (psi)2
Incremental display steps (psi) - positive only
0 psi to 1 psi 1500 1500 0.001
0 psi to 2 psi 1500 1500 0.001
0 psi to 5 psi 1500 1500 0.005
0 psi to 10 psi 1500 1500 0.01
0 psi to 15 psi 1500 1500 0.01
0 psi to 25 psi 1500 1500 0.02
0 psi to 50 psi 1500 1500 0.05
0 psi to 75 psi 1500 1500 0.05
0 psi to 100 psi 1500 1500 0.1
0 psi to 150 psi 1500 1500 0.1
0 psi to 200 psi 1500 1500 0.1
0 psi to 300 psi 1500 1500 0.2
0 psi to 500 psi 1500 1500 0.5
0 psi to 750 psi 1500 1500 0.5
0 psi to 1000 psi 1500 1500 1
0 psi to 1500 psi 3500 2250 1
0 psi to 2000 psi 4000 3000 1
0 psi to 3000 psi 5000 4500 2
0 psi to 5000 psi 7000 7000 5
0 psi to 7500 psi 9500 9500 5
0 psi to 10000 psi
12000 12000 5
1 Maximum line pressure is the amount of pressure that can be placed on both sides of the diaphragm
2 Maximum safe overpressure is the pressure which the unit can experi-ence occasionally without the loss of accuracy or permanent damage
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Honeywell • Sensing and Control 3
Differential Digital Pressure Gauge
For reference only
MOUNTINg DIMENSIONS AND ChARACTERISTICS
DRAIN PORT2X, 1/8-27 NPT
↑
↓
↑↑
↓
↓
←
→
→3.0
3.5
3.7
5.1
← 2.25↑
MOUNTING HOLESTYPICAL EACH
SIDE1/4-28 UNF .3125"
PRESSURE PORT2X, 1/8-27 NPT
Request certified drawing before designingmountings or fixtures. Specifications subject to
change without notice.
↑
3.7
↓
3.0
↓
↑
↑
↓
5.1
← →1.82← →
DRAIN PORT2X, 1/8-27 NPT
↑ PRESSURE PORT2X, 1/8-27 NPT
MOUNTING HOLESTYPICAL EACH
SIDE1/4-28 UNF .3125 in
2.5
↑
↓↑
↓
↑
↓
3.7
5.1
2.25
← 2.25 →←→
2X, .40
OPTIONAL 3 FEETCABLE
PRESSURE PORT2X, 1/4-18 NPT
FEMALE
1 TO 25PSID
50 TO750 PSID
1000 TO10000PSID
allpressure
ranges
→← 2.2
→← 2.2
→← 2.2
ORDER gUIDE
D = Differential unit scaled from 0 psi to positive full scalevalue on the positive pressure side.*
MODEL DESIGNATION
* = Example
SERIESJD*
WJD ZD5
Models with output sIgnalB = 4 mA to 20 mA (two-wire)E = 0 Vdc to 5 VdcR = 2 programmable limits & relaysX = 0 Vdc to 5 Vdc with two limits & relaysModels with no output sIgnalW = Battery powered (9 V alkaline)*T = 110 Vac adapter (included)V = 11 Vdc to 32 Vdc (3 ft. cable)PRESSURE RANGE (PSID)
REFERENCE
Bi-directional scaling is available as an option.Please consult the factory.
ELECTRICAL CONNECTIONZ = No electrical connection (Model JDW - 9 V battery)*C = 3 foot cable (Models JDB, JDE, JDR, JDX & JDV)T = ac adapter (Model JDT)B = Bendix (opt) PTIH-10-6P or equal (connector sold separately)Call factory for availability of other electrical connections and cable lengths.
NEMA 4 CONSTRUCTION4 = NEMA 4 (not available on Model JDT)
Bar = Bar Ft H20 = Feet of waterMBar = Millibar In H20 = Inches of waterkPa = Kilopascals In Hg = Inches of mercuryMPa = Megapascals mmHg = mm of mercuryConsult factory for other units of measure not listed
FIELD SELECTABLE STANDARD UNITS OF MEASURE
This ordercode is
used ONLYif you want
NEMA 4rating
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Warranty. Honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship. Honeywell’s standard product warranty applies unless agreed to otherwise by Honeywell in writing; please refer to your order acknowledgement or consult your local sales office for specific warranty details. If warranted goods are returned to Honeywell during the period of coverage, Honeywell will repair or replace, at its option, without charge those items it finds defective. The foregoing is buyer’s sole remedy and is in lieu of all warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall honeywell be liable for consequential, special, or indirect damages.
While we provide application assistance personally, through our literature and the Honeywell web site, it is up to the customer to determine the suitability of the product in the application.
Specifications may change without notice. The information we supply is believed to be accurate and reliable as of this printing. However, we assume no responsibility for its use.
For more information about Sensing and Control products, visit www.honeywell.com/sensing or call +1-815-235-6847Email inquiries to [email protected]
NOTES1. The limit/relay models include two LED status indicators on front
face and two form C relays (normally open, common, normally closed) that are rated at a maximum 24 Vdc/Vac at 1 A or 48 Vdc/Vac at 1/2 A.
WARNINgPERSONAL INJURY
• DO NOT USE these products as safety or emergency stop devices or in any other application where failure of the product could result in personal injury.
Failure to comply with these instructions could result in death or serious injury.
WARNINgMISUSE OF DOCUMENTATION
• The information presented in this catalogue is for reference only. DO NOT USE this document as product installation information.
• Complete installation, operation and maintenance information is provided in the instructions supplied with each product.
Failure to comply with these instructions could result in death or serious injury.
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Differential Pressure GaugeModel JG
DESCRIPTIONThe hand-held Model JG wet/wet differential pressure gauge de-
of 0.2 % coupled with an enhanced resolution, 4½-digit display
makes this unit an excellent transfer standard for calibrating
pressure measuring equipment.
The JG is rugged and features high/low pressure capture with an
update rate of three times per second. These units are manufac-
tured from stainless steel and use sensor technology which has
no moving parts, requires little recalibration, and has excellent
overpressure tolerance.
Each unit has a membrane face with raised buttons and tactile
feedback for setup and operation. The high, low, and clear but-
tons are easily accessible on this front membrane. Zero adjust-
ment and zero offset/tare functions are standard on each unit.
Calibration and setup parameters are stored on a memory chip
to protect from loss even when power is interrupted. Unauthor-
ized set ups and calibrations are also blocked with internal
security. Various combinations of the front panel buttons can be
de-activated.
FEATURES• High accuracy: 0.2 % full scale
• -1 °C to 71 °C [30 °F to 160 °F] operating temperature
• Enhanced resolution
• Stainless steel construction
• On/off switch
• CE compliant (certain models, consult factory)
• 4½ digit display with 0.5 in height
• Optional carrying case and panel mounting ring
• Optional NEMA 4 rating
• 9 V battery power
• High/low capture and store
• Four digit display
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
2 Honeywell • Sensing and Control
Model JG
PERFORMANCE SPECIFICATIONS
Characteristic Measure
Accuracy 0.2 % full scale
Maximum line pressure 500 psid
High and low capture Standard
Update speed 3 times per sec
ENVIRONMENTAL SPECIFICATIONS
Characteristic Measure
Temperature, operating -1 °C to 71 °C [30 °F to 160 °F]
ELECTRICAL SPECIFICATIONS
Characteristic Measure
Rating NEMA 2
Power, Model JGW One or two 9 V alkaline batteries (included)
Power, Model JGT 110 Vac adapter @ 60 Hz (included)
Power, Model JGV 11 Vdc to 32 Vdc @ 100 mA (3 ft cable included)
MECHANICAL SPECIFICATIONS
Characteristic Measure
Diameter 93,98 mm [3.7 in]
Display 4 LCD digits - 12,7 mm [0.5 in] high
Pressure port 1/4-18 NPT male
Wetted parts Stainless steel
Case material Stainless steel
Low battery indication Standard
Face membrane Tactile feedback raised buttons
Calibration data Stored on memory chip
ORDER gUIDE
W = Battery powered (9 V alkaline)*T = 110 Vac adapter (included)V = 11 Vdc to 32 Vdc (3 ft. cable)B = 4 mA to 20 mA (two-wire)E = 0 Vdc to 5 VdcR = Two programmable limits & relaysX = 0 Vdc to 5 Vdc with limits & relays
* = Example
SERIESJG
JG W 5 D
POWER
ELECTRICAL CONNECTIONZ = No electrical connection (Model JGW - 9 V battery)*C = 3 foot cable (Model JGV)T = ac adapter (Model JGT)
Call factory for availability of other electrical connections and cable lengths.
Z
OPTIONAL4 = NEMA 4NEMA 4 option also provides temperature range of 0-180°F
Each gauge has the following scaling built in for field selection:OPTIONAL UNITS OF MEASURE
Bar = BarmBar = MillibarkPa = KilopascalsMPa = Megapascals
Ft H20 = Feet of waterIn H20 = Inches of waterIn Hg = Inches of mercurymmHg = mm of mercury
Consult factory for other units of measure not listed
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Warranty. Honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship. Honeywell’s standard product warranty applies unless agreed to otherwise by Honeywell in writing; please refer to your order acknowledgement or consult your local sales office for specific warranty details. If warranted goods are returned to Honeywell during the period of coverage, Honeywell will repair or replace, at its option, without charge those items it finds defective. The foregoing is buyer’s sole remedy and is in lieu of all warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall Honeywell be liable for consequential, special, or indirect damages.
While we provide application assistance personally, through our literature and the Honeywell web site, it is up to the customer to determine the suitability of the product in the application.
Specifications may change without notice. The information we supply is believed to be accurate and reliable as of this printing. However, we assume no responsibility for its use.
For more information about Sensing and Control products, visit www.honeywell.com/sensing or call +1-815-235-6847Email inquiries to [email protected]
WARNINgPERSONAL INJURY
• DO NOT USE these products as safety or emergency stop devices or in any other application where failure of the product could result in personal injury.
Failure to comply with these instructions could result in death or serious injury.
WARNINgMISUSE OF DOCUMENTATION
• The information presented in this catalogue is for reference only. DO NOT USE this document as product installation information.
• Complete installation, operation and maintenance information is provided in the instructions supplied with each product.
Failure to comply with these instructions could result in death or serious injury.
NOTES1. The limit/relay models include two LED status indicators on front face
anåçd two form C relays (normally open, common, normally closed) that are rated at a maximum 24 Vdc/Vac at 1 A or 48 Vdc/Vac at 1/2 A.
ADDITIONAL SPECIFICATIONS
Pressure range (psi) Maximum safe over pressure (psi)1
Model Jg
0 psi to 1 psi = 1 (opt) 10 0.001
0 psi to 5 psi = 5 (opt) 25 0.005
0 psi to 15 psi = 15 75 0.01
0 psi to 30 psi = 30 150 0.02
0 psi to 50 psi = 50 250 0.05
0 psi to 100 psi = 100 500 0.1
0 psi to 200 psi = 200 1000 0.1
0 psi to 300 psi = 300 1200 0.2
0 psi to 500 psi = 500 1500 0.5
0 psi to 750 psi = 750 1500 0.5
0 psi to 1000 psi = 1K 2000 1
0 psi to 1500 psi = 1.5K 3000 1
0 psi to 2000 psi = 2K 4000 1
0 psi to 3000 psi = 3K 6000 2
0 psi to 5000 psi = 5K 7500 5
0 psi to 7500 psi = 7.5K 12000 5
0 psi to 10000 psi = 10K 15000 51 Maximum safe overpressure is the pressure which the unit can experience occasionally without the loss of accuracy or permanent damage
SS9 AD9 Pressure adapter (Zinc plated steel) to 7/16-20 UNF male with 37° flare*
CC2 Carrying case
MR2 Panel mounting ring
NISTCERTS NIST certification (in addition to NIST statement)
* Call factory for other fittings
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Model JH
DESCRIPTION
Using high pressure autoclave fittings, the Series JH digital pres-
sure test gauge with 0.2 % full scale accuracy uses transducer
technology and a stainless steel diaphragm for high over pres-
sure protection. The transducer technology provides enhanced
accuracy over the entire pressure range. The JH has no moving
parts and thus, may provide a long life with fewer re-calibrations.
The stainless steel NEMA construction also provides EMI and
RFI protection.
The JH provides high resolution with an easy to read digital
display. There are no operator errors due to interpolation of hash
marks or parallax errors. The units can be scaled to read in
various engineering units. PSI pressures are read x 10 with the
4½-digit display. The Model JHB provides a 4 mA to 20 mA, two-
wire output. The Model JHE provides a 0 Vdc to 5 Vdc output.
The Model JHR has two programmable limits and relays with no
analog output. The Model JHX provides a 0 Vdc to 5 Vdc output
with two programmable limits and relays for process control
or alarm indication. The Model JHW is powered by one or two
common 9 V alkaline batteries. The Model JHT is powered by a
110 Vac adapter. The JHV, JHB, JHE, JHR and JHX models are
powered by an 11 Vdc to 32 Vdc power supply.
Each unit has a membrane face with raised buttons and tactile
feedback for setup and operation. The high, low, and clear but-
tons are easily accessible on this front membrane. Zero adjust-
ment and zero offset/tare functions are standard on each unit.
Calibration and setup parameters are stored on a memory chip
to protect from loss even when power is interrupted. Unauthor-
ized set ups and calibrations are also blocked with internal
security. Various combinations of the front panel buttons can be
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
2Honeywell•SensingandControl
Model JH
PERFORMANCE SPECIFICATIONS
Characteristic Measure
Linearity and hysteresis 0.2%fullscale(betterthantestgaugeaccuracy)
Pressure range 0 psi to 15000, 20000, 25000, 30000, 35000, 40000,50000,60000psi
High and low capture Standard
Update speed 3 times per sec
Zero and span signal adjustment
Standard: Models JHB, JHE, JHX
ENVIRONMENTAL SPECIFICATIONS
Characteristic Measure
Temperature, operating -1°Cto71°C[30°Fto160°F]
ELECTRICAL SPECIFICATIONS
Characteristic Measure
Rating NEMA2(optionalNEMA4)
Power, Model JHW Oneortwo9Valkalinebatteries(in-cluded)
Power, Model JHT 110Vacadapter@60Hz(included)
Power, Model JHV 11Vdcto32Vdc@100mA(3ftcableincluded)
Power, Model JHB 11Vdcto32Vdc(dependingonloopresistance)@20mA
Pressure port 9/16-18UNF-2Bfemale(perAutoclaveAEF250-C)
Wetted parts Stainless steel
Case material Stainless steel
Face membrane Tactile feedback raised buttons
Calibration data Stored on memory chip
Low battery indication Standard: Model JHW
Limits and relays Models JHR and JHX1
MOUNTINg DIMENSIONS AND CHARACTERISTICS
For reference only
ADDITIONAL SPECIFICATIONS
Pressure range (psi) Maximum safe over pressure (psi)2
Incremental display steps
0 psi to 15000 psi = 15K 20000 1 x 10
0 psi to 20000 psi = 20K 25000 1 x 10
0 psi to 25000 psi = 25K 31000 1 x 10
0 psi to 30000 psi = 30K 37000 2 x 10
0 psi to 35000 psi = 35K 43000 5 x 10
0 psi to 40000 psi = 40K 50000 5 x 10
0 psi to 50000 psi = 50K 62000 5 x 10
0psito60000psi=60K 75000 5 x 10
2 Maximum safe overpressure is the pressure which the unit can experience oc-casionally without the loss of accuracy or permanent damage
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Warranty. Honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship. Honeywell’s standard product warranty applies unless agreed to otherwise by Honeywell in writing; please refer to your order acknowledgement or consult your local sales office for specific warranty details. If warranted goods are returned to Honeywell during the period of coverage, Honeywell will repair or replace, at its option, without charge those items it finds defective. The foregoing is buyer’s sole remedy and is in lieu of all warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall Honeywell be liable for consequential, special, or indirect damages.
While we provide application assistance personally, through our literature and the Honeywell web site, it is up to the customer to determine the suitability of the product in the application.
Specifications may change without notice. The information we supply is believed to be accurate and reliable as of this printing. However, we assume no responsibility for its use.
For more information about Sensing and Control products, visit www.honeywell.com/sensingorcall+1-815-235-6847Email inquiries to [email protected]
Models with Output SignalB = 4 mA to 20 mA (two-wire)E = 0 Vdc to 5 VdcR = 2 programmable limits & relaysX = 0 Vdc to 5 Vdc with two limits & relays
Models with No Output SignalW = Battery powered (9 V alkaline) *T = 110 Vac adapter (included)V = 11 Vdc to 32 Vdc (3 ft cable)
MODEL DESIGNATION
SERIESJH*
Z = No electrical connection (Model JHW - 9 V battery)*C = 3 foot cableT = ac adapter (Model JHT)B = Bendix (opt) PTIH-10-6P or equal (connector sold separately)Call factory for availability of other electrical connections and cablelengths.
This ordercode is
used ONLYif you want
NEMA 4rating
Bar = Bar Ft H20 = Feet of waterMBar = Millibar In H20 = Inches of waterkPa = Kilopascals In Hg = Inches of mercuryMPa = Megapascals mmHg = mm of mercury
Consult factory for other units of measure not listed
FIELD SELECTABLE STANDARD UNITS OF MEASURE
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Digital Pressure GaugeModel JK
DESCRIPTIONThe Series JK digital pressure test gauge with 0.2 % full scale
accuracy uses transducer technology and a stainless steel
diaphragm for high overpressure protection. The transducer
technology provides enhanced accuracy over the entire pres-
sure range. The JK has no moving parts and thus, may provide
a long life with fewer re-calibrations. The stainless steel NEMA
construction also provides EMI and RFI protection. The JK
provides high resolution with an easy to read digital display.
There are no operator errors due to interpolation of hash marks
or parallax errors.
The Model JKW is powered by one or two common 9 V alkaline
batteries. The Model JKT is powered by a 110 Vac adapter. The
Model JKV is powered by an 11 Vdc to 32 Vdc power supply.
Each unit has a membrane face with raised buttons and tactile
feedback for setup and operation. The high, low, and clear but-
tons are easily accessible on this front membrane. Zero adjust-
ment and zero offset/tare functions are standard on each unit.
Calibration and setup parameters are stored on a memory chip
to protect from loss even when power is interrupted. Unauthor-
ized set ups and calibrations are also blocked with internal
security. Various combinations of the front panel buttons can be
de-activated.
FEATURES• Rangesto10000psi
• 0.2%accuracy
• Fieldselectableengineeringunits
• Available-18°Cto82°C[0°Fto180°F]operatingtem-
perature4
• Stainlesssteelconstruction
• 4½digitdisplaywith0.5inheight
• Customerrecalibration
• 9Vbatterypower
• High/lowcaptureandstore
• On/offswitch
• CEcompliant(certainmodels,consultfactory)
• Optionalcarryingcaseandpanelmountingring
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Pressure port 1-4/18NPTmale(300psiandbelow)9/16-18UNF-2BfemalestraightthreadwithSAEspecJ514o-ringboss(500psiandabove)
Face membrane Tactile feedback raised buttons
Case material Stainless steel
Wetted parts Stainless steel
MOUNTINg DIMENSIONS AND CHARACTERISTICS
For reference only
Pressure range (psi)
1 5 15 30 50 100 200 300 500
Max. safe over pres-sure (psi)
10 25 75 150 250 500 1000 1200 1500
Incremen-tal display steps
0.001 0.005 0.01 0.02 0.05 0.1 0.1 0.2 0.5
Pressure range (psi)
750 1000 1500 2000 3000 5000 7500 10000
Max. safe over pres-sure (psi)
1500 2000 3000 4000 6000 7500 12000 15000
Incremen-tal display steps
0.5 1 1 1 2 5 5 5
ADDITIONAL SPECIFICATIONS
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Warranty. Honeywellwarrantsgoodsofitsmanufactureasbeing free of defective materials and faulty workmanship. Honeywell’sstandardproductwarrantyappliesunlessagreedtootherwisebyHoneywellinwriting;pleaserefertoyourorder acknowledgement or consult your local sales office for specific warranty details. If warranted goods are returned to Honeywellduringtheperiodofcoverage,Honeywellwillrepairor replace, at its option, without charge those items it finds defective. The foregoing is buyer’s sole remedy and is in lieu of all warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall Honeywell be liable for consequential, special, or indirect damages.
While we provide application assistance personally, through our literatureandtheHoneywellwebsite,itisuptothecustomertodetermine the suitability of the product in the application.
Specifications may change without notice. The information we supply is believed to be accurate and reliable as of this printing. However,weassumenoresponsibilityforitsuse.
For more information about Sensing and Control products, visit www.honeywell.com/sensingorcall+1-815-235-6847Email inquiries to [email protected]
Failure to comply with these instructions could result in death or serious injury.
NOTES1. Accuracies stated are for best fit straight line for all errors including
linearity, hysteresis and repeatability through zero.2. Consult factory for optional units of measure.3. Consult factory for optional electrical connectors and cable lengths.4. -18°Cto82°C[0°Fto180°F]operatingtemperatureonlywith
optional NEMA 4 rating.
ORDER gUIDE
W = Battery powered (9 V alkaline)*T = 110 Vac adapter (included)V = 11 Vdc to 32 Vdc (3 ft. cable)
REFERENCEG = Gage (std) reads zero at atmosphere *A = Absolute (opt) reads zero at vacuum (15 psi or higher)V = Vacuum (opt)C = Compound (opt) reads both positive & negative
(vacuum) pressure
ELECTRICAL CONNECTIONZ = No electrical connection (Model JKW - 9 volt battery)*C = 3 foot cable (Model JKV)T = ac adapter (Model JKT)
Call factory for availability of other electrical connections and cable lengths.
Z
OPTIONAL4 = NEMA 4 (Not available on JKT)
NEMA 4 option also provides temperature range of 0-180°F
4
Each gauge has the following scaling built in for field selection:FIELD SELECTABLE STANDARD UNITS OF MEASURE
Bar = BarmBar = MillibarkPa = KilopascalsMPa = Megapascals
Ft H20 = Feet of waterIn H20 = Inches of waterIn Hg = Inches of mercurymmHg = mm of mercury
Consult factory for other units of measure not listed
W 200 G
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Food/Pharmaceutical Digital Pressure GaugeModel JP
DESCRIPTIONUsing Tri-Clover sanitary fittings, the Series JP digital pres-
sure test gauge with 0.2% full scale accuracy uses transducer
technology and a stainless steel diaphragm for high over pres-
sure protection. The transducer technology provides enhanced
accuracy over the entire pressure range. The JP has no moving
parts and thus, may provide a long life with fewer re-calibrations.
The stainless steel NEMA construction also provides EMI and
RFI protection.
The JP provides high resolution with an easy to read 4½-digit
display. There are no operator errors due to interpolation of hash
marks or parallax errors. The units can be scaled to read in vari-
ous engineering units such as InHg, Ft H2O, etc. The Model JPB
provides a 4 mA to 20 mA, two-wire output. The Model JPE pro-
vides a 0 Vdc to 5 Vdc output. The Model JPR has two program-
mable limits and relays with no analog output. The Model JPX
provides a 0 Vdc to 5 Vdc output with two programmable limits
and relays for process control or alarm indication.
The Model JPW is powered by one or two common 9 V alkaline
batteries. The Model JPT is powered by a 110 Vac adapter. The
Model JPV is powered by an 11 Vdc to 32 Vdc power supply.
Each unit has a membrane face with raised buttons and tactile
feedback for setup and operation. The high, low, and clear but-
tons are easily accessible on this front membrane. Zero adjust-
ment and zero offset/tare functions are standard on each unit.
Calibration and setup parameters are stored on a memory chip
to protect from loss even when power is interrupted. Unauthor-
ized set ups and calibrations are also blocked with internal
security. Various combinations of the front panel buttons can be
de-activated.
FEATURES• Tri-Cloversanitaryfittings
• Twoprogrammablelimitsandrelays(optional)
• Testgaugeaccuracy-0.2%fullscale
• Highandlowdetection-Microprocessorbased
• NEMA4
• 4½digitdisplaywith0.5inheight
• Customerrecalibration
• Zerooffset/tare
• On/offswitchdisablefeature
• Optionalcarryingcaseandpanelmountingring
• Twoprogrammablelimitsandrelays(optional)
• NISTtraceable(optional)
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
2Honeywell•SensingandControl
Model JP
PERFORMANCE SPECIFICATIONS
Characteristic Measure
Linearity and hysteresis 0.2%fullscale(betterthantestgaugeaccuracy)
Pressure range 0 psi to 1, 2, 5, 10, 20, 50, 100, 200, 500 psi
High and low capture Standard
Update speed 3 times per sec
Zero and span signal adjustment
Standard: Models JPB, JPE, JPX
ENVIRONMENTAL SPECIFICATIONS
Characteristic Measure
Temperature, operating -1 °C to 71 °C [30 °F to 160 °F]
ELECTRICAL SPECIFICATIONS
Characteristic Measure
Rating NEMA 4
Power, Model JPW One or two 9 V alkaline batteries (included)
Power, Model JPT 110Vacadapter@60Hz(included)
Power, Model JPV 11 Vdc to 32 Vdc @ 100 mA (3ftcableincluded)
Power, Model JPB 11Vdcto32Vdc(dependingonloopresistance)@20mA
Pressure port Sanitary flanges: 1.5 in, 2.0 in, 2.5 in, 3.0 in
Wetted parts Stainless steel
Case material Stainless steel
Face membrane Tactile feedback raised buttons
Calibration data Stored on memory chip
Low battery indication Standard: Model JPW
Limits and relays Models JPR and JPX*
MOUNTINg DIMENSIONS AND CHARACTERISTICS
Request certified drawing before designing mountings or fixtures.Specifications subject to change without notice.
3 FEET CABLE EXIT *
1.5" TRI-CLOVERSANITARY FLANGE←
← →
↑
↓
2.2
3.7
5.2
1.2← →
→←
2.0" TRI-CLOVERSANITARY FLANGE
2.5" TRI-CLOVERSANITARY FLANGE
3.0" TRI-CLOVERSANITARY FLANGE
*Models JPB, JPE, JPR, JPX, JPVNo cable for battery powered Model JPW
ADDITIONAL SPECIFICATIONS
Maximum safe over pressure (psi)1, 2
Pressure range 0 to: (psi)
1.5 in flange dia.
2.0 in flange dia.
2.5 in flange dia.
3.0 in flange dia.
Incre-mental dis-play steps
1(opt) 10 10 10 10 0.001
2(opt) 15 15 15 15 0.002
5(opt) 25 25 25 25 0.005
10 50 50 50 50 0.01
15 75 75 75 75 0.01
25 125 125 125 125 0.02
50 250 250 250 250 0.05
100 500 500 500 350 0.1
250 600 600 600 350 0.2
400 600 600 600 NA 0.5
500 600 600 NA NA 0.5
Max. flange pressure at 100 °F
600 600 600 350
1 Maximum safe overpressure is the pressure which the unit can experience oc-casionally without the loss of accuracy or permanent damage.
2 Maximum pressure: 1 1/2, 2, 2 1/2 inch dia. flange - 600 psi at 100 °F; 3 inch dia. flange - 350 psi at 100 °F temperatures above; 100 °F reduce maximum flange pressure. Please call factory.
For reference only
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Model JP Food/Pharmaceutical Digital Pressure Gauge
Warranty. Honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship. Honeywell’s standard product warranty applies unless agreed to otherwise by Honeywell in writing; please refer to your order acknowledgement or consult your local sales office for specific warranty details. If warranted goods are returned to Honeywell during the period of coverage, Honeywell will repair or replace, at its option, without charge those items it finds defective. The foregoing is buyer’s sole remedy and is in lieu of all warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall Honeywell be liable for consequential, special, or indirect damages.
While we provide application assistance personally, through our literature and the Honeywell web site, it is up to the customer to determine the suitability of the product in the application.
Specifications may change without notice. The information we supply is believed to be accurate and reliable as of this printing. However, we assume no responsibility for its use.
For more information about Sensing and Control products, visit www.honeywell.com/sensing or call +1-815-235-6847Email inquiries to [email protected]
Failure to comply with these instructions could result in death or serious injury.
NOTES1. The limit/relay models include two LED status indicators on front
faceandtwoformCrelays(normallyopen,common,normallyclosed)thatareratedatamaximum24Vdc/Vacat1Aor48Vdc/Vac at 1/2 A.
ORDER gUIDE
Z* = Example
G250WJP
ELECTRICAL CONNECTION
G = Gage (std) reads zero at atmosphere*A = Absolute (opt) reads zero at vacuum (15 psi or higher)V = Vacuum (opt) scaled in In Hg (15 psi or lower)C = Compound (opt) reads both positive and negative
(vacuum) pressure
REFERENCE
SERIESJP*MODEL DESIGNATIONModels with output signalB = 4 mA to 20 mA (two-wire)E = 0 Vdc to 5 VdcR = Two programmable limits & relaysX = 0 Vdc 5 Vdc with two limits & relaysModels with no output signalW= Battery powered (9 V alkaline) *T = 110 Vac adapter (included)V = 11 Vdc to 32 Vdc (3 ft. cable)
PRESSURE RANGE (PSI)
Z = No electrical connection (Model JPW - 9 V battery)*C = 3 foot cableT = ac adapter (Model JPT)B = Bendix (opt) PTIH-10-6P or equal (connector sold separately)
SANITARY FLANGE SIZE :P = 1.5 inches (up to 500 psi) (does not comply with 3A standards)Q = 2.0 inches (up to 500 psi)R = 2.5 inches (up to 400 psi)S = 3.0 inches (up to 250 psi)
Call factory for availability of other electrical connections and cable lengths.
1 = 0-1 (opt)2 = 0-2 (opt)5 = 0-5 (opt)10 = 0-10
15 = 0-1525 = 0-2550 = 0-50100 = 0-100
250= 0-250*400= 0-400500= 0-500
Bar = Bar Ft H20 = Feet of waterMBar = Millibar In H20 = Inches of waterkPa = Kilopascals In Hg = Inches of mercuryMPa = Megapascals mmHg = mm of mercury
Consult factory for other units of measure not listed
FIELD SELECTABLE STANDARD UNITS OF MEASURE
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Remote Pressure Digital Pressure Gauge
Model JR
DESCRIPTION
With a 6-ft microchange cable connection, the Model JR digital
pressure test gauge with 0.2 % full scale accuracy uses trans-
ducer technology and a stainless steel diaphragm for high
over pressure protection. The transducer technology provides
enhanced accuracy over the entire pressure range. The JR has
no moving parts and may provide a long life with fewer re-cal-
ibrations. The JR provides high resolution with an easy to read
4½-digit display. There are no operator errors due to interpola-
tion of hash marks or parallax errors. The units can be scaled to
read in various engineering units such as InHg, Ft H2O, etc.
The Model JRB provides a 4 mA to 20 mA, two-wire output. The
Model JRE provides a 0 Vdc to 5 Vdc output. The Model JRR
has two programmable limits and relays with no analog output.
The Model JRX provides a 0 Vdc to 5 Vdc output with two pro-
grammable limits and relays for process control or alarm indica-
tion. The Model JRW is powered by one or two common
9 V alkaline batteries. The Model JRT is powered by a 110 Vac
adapter. The Model JRV is powered by an 11 Vdc to 32 Vdc
power supply.
Each unit has a membrane face with raised buttons and tactile
feedback for setup and operation. The high, low, and clear but-
tons are easily accessible on this front membrane. Zero adjust-
ment and zero offset/tare functions are standard on each unit.
Calibration and setup parameters are stored on a memory chip
to protect from loss even when power is interrupted. Unauthor-
ized set ups and calibrations are also blocked with internal
security. Various combinations of the front panel buttons can be
de-activated.
FEATURES• Portablebatterypoweredavailable
• Twoprogrammablelimitsandrelays(optional)
• Testgaugeaccuracy-0.2%fullscale
• Highandlowdetection-Microprocessorbased
• Rangesto60000psi-gage,absolute,vacuum,orcom-
pound
• Optionalpressureportadapters
• 4½digitdisplaywith0.5inheight
• Customerrecalibration
• Zerooffset/tare
• On/offswitchdisablefeature
• Optionalcarryingcaseandpanelmountingring
• NEMA4rating(optional)
• NISTtraceable(optional)
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
2Honeywell•SensingandControl
Model JR
PERFORMANCE SPECIFICATIONS
Characteristic Measure
Linearity and hysteresis 0.2%fullscale(betterthantestgaugeaccuracy)
Pressure range (psi) Maximum safe over pressure (psi)1
Model JR
0psito1psi=1(opt) 10 0.001
0psito5psi=5(opt) 25 0.005
0 psi to 15 psi = 15 75 0.01
0 psi to 30 psi = 30 150 0.02
0 psi to 50 psi = 50 250 0.05
0 psi to 100 psi = 100 500 0.1
0 psi to 200 psi = 200 1000 0.1
0 psi to 300 psi = 300 1200 0.2
0 psi to 500 psi = 500 1500 0.5
0 psi to 750 psi = 750 1500 0.5
0 psi to 1000 psi = 1K 2000 1
0 psi to 1500 psi = 1.5K 3000 1
0 psi to 2000 psi = 2K 4000 1
0 psi to 3000 psi = 3K 6000 2
0 psi to 5000 psi = 5K 7500 5
0 psi to 7500 psi = 7.5K 12000 5
0 psi to 10000 psi = 10K 15000 5
(SeeSeriesJHforrangesabove10000psi)
1 Maximum safe overpressure is the pressure which the unit can experience oc-casionally without the loss of accuracy or permanent damage
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Warranty. Honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship. Honeywell’s standard product warranty applies unless agreed tootherwisebyHoneywellinwriting;pleaserefertoyourorder acknowledgement or consult your local sales office for specific warranty details. If warranted goods are returned to Honeywell during the period of coverage, Honeywell will repair or replace, at its option, without charge those items it finds defective. The foregoing is buyer’s sole remedy and is in lieu of all warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall Honeywell be liable for consequential, special, or indirect damages.
While we provide application assistance personally, through our literature and the Honeywell web site, it is up to the customer to determine the suitability of the product in the application.
Specificationsmaychangewithoutnotice.Theinformationwesupply is believed to be accurate and reliable as of this printing. However, we assume no responsibility for its use.
FormoreinformationaboutSensingandControlproducts,visitwww.honeywell.com/sensing or call +1-815-235-6847Email inquiries to [email protected]
Failure to comply with these instructions could result in death or serious injury.
NOTES1. The limit/relay models include two LED status indicators on front
faceandtwoformCrelays(normallyopen,common,normallyclosed)thatareratedatamaximum24Vdc/Vacat1Aor48Vdc/Vac at 1/2 A.
ORDER gUIDE
* = ExampleZG200WJR ( )
4 = NEMA 4 (Not available on Model JRT)NEMA 4 CONSTRUCTION
SERIES
MODEL DESIGNATIONJR*
Models with output signalB = 4 mA to 20 mA (two-wire)E = 0 Vdc to 5 VdcR = Two programmable limits & relaysX = 0 Vdc to 5 Vdc with two limits & relaysModels with No Output SignalW= Battery powered (9 volt alkaline) *T = 110 Volt AC adapter (included)V = 11 to 32 VDC (3 ft. cable)
G = Gage (std) reads zero at atmosphere*A = Absolute (opt) reads zero at vacuum(15 psi or higher)V = Vacuum (opt) scaled in inches of mercury (15 psi or lower)C = Compound (opt) reads both positive and negative
(vacuum) pressure
REFERENCE
ELECTRICAL CONNECTIONZ = No electrical connection (Model JRW - 9 V battery)*C = 3 foot cableT = ac adapter (Model JRT)B = Bendix (opt) PTIH- 10-6P or equal (connector sold separately
- back connection only)Call Factory for availability of other electrical connections and cable lengths.
Bar = Bar Ft H20 = Feet of waterMBar = Millibar In H20 = Inches of waterkPa = Kilopascals In Hg = Inches of mercuryMPa = Megapascals mmHg = mm of mercury
Consult factory for other units of measure not listed
FIELD SELECTABLE STANDARD UNITS OF MEASURE
This ordercode is
used ONLYif you want
NEMA 4rating
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Model JS
DESCRIPTIONThe Model JS digital pressure test gauge with 0.2 % full scale
accuracy uses transducer technology and a stainless steel dia-
phragm for high over pressure protection. The transducer tech-
nology provides enhanced accuracy over the entire pressure
range. The JS has no moving parts and thus, may provide a long
life with fewer re-calibrations. The stainless steel NEMA con-
struction also provides EMI and RFI protection. The JS provides
high resolution with an easy to read digital display. There are no
operator errors due to interpolation of hash marks or parallax er-
rors. The units can be scaled to read in various engineering units
such as InHg, Ft H2O, etc.
The Model JSB provides a 4 mA to 20 mA, two-wire output.
The Model JSE provides a 0 Vdc to 5 Vdc output. The Model
JSR has two programmable limits and relays with no analog
output. The Model JSX provides a 0 Vdc to 5 Vdc output with
two programmable limits and relays for process control or alarm
indication.
Each unit has a membrane face with raised buttons and tactile
feedback for setup and operation. The high, low, and clear but-
tons are easily accessible on this front membrane. Zero adjust-
ment and zero offset/tare functions are standard on each unit.
Calibration and setup parameters are stored on a memory chip
to protect from loss even when power is interrupted. Unauthor-
ized set ups and calibrations are also blocked with internal
security. Various combinations of the front panel buttons can be
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
2Honeywell•SensingandControl
Model JS
PERFORMANCE SPECIFICATIONS
Characteristic Measure
Linearity and hysteresis 0.2%fullscale(betterthantestgaugeaccuracy)
Pressure range 0 psi to 1,5,15,30,50,100,200,300,500,750,1000,1500,2000,3000,5000,7500,10000psi
High and low capture Standard
Update speed 3timespersec
Zero and span signal adjustment
Standard: Models JSB, JSE, JSX
ENVIRONMENTAL SPECIFICATIONS
Characteristic Measure
Temperature, operating -1°Cto71°C[30°Fto160°F]
ELECTRICAL SPECIFICATIONS
Characteristic Measure
Rating NEMA2(optionalNEMA4)
Power, Model JSB 11Vdcto32Vdc(dependingonloopresistance)@20mA
Power, Model JSE 11Vdcto32Vdc@100mA
Power, Model JSR 11Vdcto32Vdc@100mA
Power, Model JSX 11Vdcto32Vdc@100mA
Electrical connection 3ftcable(standard)
MECHANICAL SPECIFICATIONS
Characteristic Measure
Diameter 93,98mm[3.7in]
Display 4½LCDdigits-12,7mm[0.5in]high
Pressure port 1/4-18NPTmale(1psito300psi);9/16-18UNF-2BfemalestraightthreadwithSAEspecJ514o-ringboss(500psiandabove)
Wetted parts Stainless steel
Case material Stainless steel
Face membrane Tactile feedback raised buttons
Calibration data Stored on memory chip
Limits and relays Models JSR and JSX
MOUNTINg DIMENSIONS AND CHARACTERISTICS
For reference only
ADDITIONAL SPECIFICATIONS
Pressure range (psi) Maximum safe over pressure (psi)1
Model JS
0psito1psi=1(opt) 10 0.001
0psito5psi=5(opt) 25 0.005
0psito15psi=15 75 0.01
0psito30psi=30 150 0.02
0psito50psi=50 250 0.05
0psito100psi=100 500 0.1
0psito200psi=200 1000 0.1
0psito300psi=300 1200 0.2
0psito500psi=500 1500 0.5
0psito750psi=750 1500 0.5
0psito1000psi=1K 2000 1
0psito1500psi=1.5K 3000 1
0psito2000psi=2K 4000 1
0psito3000psi=3K 6000 2
0psito5000psi=5K 7500 5
0psito7500psi=7.5K 12000 5
0psito10000psi=10K 15000 5
1 Maximum safe overpressure is the pressure which the unit can experience oc-casionally without the loss of accuracy or permanent damage
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Warranty. Honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship. Honeywell’s standard product warranty applies unless agreed tootherwisebyHoneywellinwriting;pleaserefertoyourorder acknowledgement or consult your local sales office for specific warranty details. If warranted goods are returned to Honeywell during the period of coverage, Honeywell will repair or replace, at its option, without charge those items it finds defective. The foregoing is buyer’s sole remedy and is in lieu of all warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall Honeywell be liable for consequential, special, or indirect damages.
While we provide application assistance personally, through our literature and the Honeywell web site, it is up to the customer to determine the suitability of the product in the application.
Specifications may change without notice. The information we supply is believed to be accurate and reliable as of this printing. However, we assume no responsibility for its use.
For more information about Sensing and Control products, visit www.honeywell.com/sensingorcall+1-815-235-6847Emailinquiriestoinfo.sc@honeywell.com
G = Gage (std) reads zero at atmosphere*A = Absolute (opt) reads zero at vacuum (15 psi or higher)V = Vacuum (opt) scaled in In Hg (15 psi or lower)C = Compound (opt) reads both positive and negative
(vacuum) pressure
OUTPUT SIGNAL
* = Example
SERIESJS*
B = 4 mA to 20 mA (two-wire)*E = 0 Vdc to 4 VdcR = 2 programmable limits & relaysX = 0 Vdc to 5 Vdc with two limits & relays
ELECTRICAL CONNECTIONC = 3 foot cable*B = Bendix (opt) - PTIH-10-6P or equal (connector sold seperately)
Call factory for availability of other electrical connections and cable lengths
This ordercode is
used ONLYif you want
NEMA 4rating
Bar = Bar Ft H20 = Feet of waterMBar = Millibar In H20 = Inches of waterkPa = Kilopascals In Hg = Inches of mercuryMPa = Megapascals mmHg = mm of mercury
Consult factory for other units of measure not listed
FIELD SELECTABLE STANDARD UNITS OF MEASURE
ORDER gUIDE
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Digital Pressure Gauge With VCR Fittings
Model JV
DESCRIPTION
Using VCR, the Series JV digital pressure test gauge with 0. 2%
full scale accuracy uses transducer technology and a stainless
steel diaphragm for high over pressure protection. The transduc-
er technology provides enhanced accuracy over the entire pres-
sure range. The JV has no moving parts and thus, may provide a
long life with fewer re-calibrations.
The stainless steel NEMA construction also provides EMI and
RFI protection. The JV provides high resolution with an easy to
read digital display. There are no operator errors due to interpo-
lation of hash marks or parallax errors. The units can be scaled
to read in various engineering units, such as in-Hg, ft-H20, etc.
The Model JVB provides a 4 mA to 20 mA, two-wire output. The
Model JVE provides a 0 Vdc to 5 Vdc output. The Model JVR has
two programmable limits and relays with no analog output. The
Model JVX provides a 0 Vdc to 5 Vdc output with two program-
mable limits and relays for process control or alarm indication.
The Model JVW is powered by one or two common 9 V alkaline
batteries. The Model JVT is powered by a 110 Vac adapter. The
JVV, JVB, JVE, JVR, and JVX models are powered by an 11 Vdc
to 32 Vdc power supply.
Each unit has a membrane face with raised buttons and tactile
feedback for setup and operation. The high, low, and clear but-
tons are easily accessible on this front membrane. Zero adjust-
ment and zero offset/tare functions are standard on each unit.
Calibration and setup parameters are stored on a memory chip
to protect from loss even when power is interrupted. Unauthor-
ized set ups and calibrations are also blocked with internal
security. Various combinations of the front panel buttons can be
deactivated.
FEATURES• Passivationoroxygen-cleanedoptions
• Twoprogrammablelimitsandrelays(optional)
• Testgaugeaccuracy-0.2%fullscale
• Highandlowdetection-Microprocessorbased
• Rangesto5000psi-gage,absolute,vacuum,orcompound
• 4½digitdisplaywith0.5inheight
• Customerrecalibration
• Zerooffset/tare
• On/offswitchdisablefeature
• Optionalcarryingcaseandpanelmountingrings
• NEMA4rating(optional)
• NISTtraceable(optional)
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
2Honeywell•SensingandControl
Model JV
PERFORMANCE SPECIFICATIONS
Characteristic Measure
Linearity and hysteresis 0.2%fullscale(betterthantestgaugeaccuracy)
Pressure range (psi) Maximum safe over pressure (psi)1
Model JV
0psito1psi=1(opt) 10 0.001
0psito5psi=5(opt) 25 0.005
0 psi to 15 psi = 15 75 0.01
0 psi to 30 psi = 30 150 0.02
0 psi to 50 psi = 50 250 0.05
0 psi to 100 psi = 100 500 0.1
0 psi to 200 psi = 200 1000 0.1
0 psi to 300 psi = 300 1200 0.2
0 psi to 500 psi = 500 1500 0.5
0 psi to 750 psi = 750 1500 0.5
0 psi to 1000 psi = 1K 2000 1
0 psi to 1500 psi = 1.5K 3000 1
0 psi to 2000 psi = 2K 4000 1
0 psi to 3000 psi = 3K 6000 2
0 psi to 5000 psi = 5K 7500 5
0 psi to 7500 psi = 7.5K 12000 5
0 psi to 10000 psi = 10K 15000 5
1 Maximum safe overpressure is the pressure which the unit can experience oc-casionally without the loss of accuracy or permanent damage
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Warranty. Honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship. Honeywell’s standard product warranty applies unless agreed to otherwise by Honeywell in writing; please refer to your order acknowledgement or consult your local sales office for specific warranty details. If warranted goods are returned to Honeywell during the period of coverage, Honeywell will repair or replace, at its option, without charge those items it finds defective. The foregoing is buyer’s sole remedy and is in lieu of all warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall Honeywell be liable for consequential, special, or indirect damages.
While we provide application assistance personally, through our literature and the Honeywell web site, it is up to the customer to determine the suitability of the product in the application.
Specifications may change without notice. The information we supply is believed to be accurate and reliable as of this printing. However, we assume no responsibility for its use.
For more information about Sensing and Control products, visit www.honeywell.com/sensing or call +1-815-235-6847Email inquiries to [email protected]
4 = NEMA 4 (not available on Model JVT)NEMA 4 CONSTRUCTION
( )
Models with output signalB = 4 mA to 20 mA (two-wire)E = 0 Vdc to 5 VdcR = 2 programmable limits & relaysX = 0 Vdc to 5 Vdc with two limits & relays
Models with no output signalW= Battery powered (9 V alkaline)*T = 110 Vac adapter (included)V = 11 Vdc to 32 Vdc (3 ft. cable)
PRESSURE RANGE (PSI)
G = Gage (std) reads zero at atmosphere*A = Absolute (opt) reads zero at vacuum (15 psi or higher)V = Vacuum (opt) scaled in In Hg (15 psi or lower)C = Compound (opt) reads both positive and negative
(vacuum) pressure
REFERENCE
V
ELECTRICAL CONNECTIONZ = No electrical connection (Model JVW - 9 V battery)*C = 3 foot cableT = ac adapter (Model JVT)B = Bendix (opt) (PTIH-10-6P or equal) connector sold
separatelyCall factory for availability of other electrical connections and cable lengths.
Bar = Bar Ft H20 = Feet of waterMBar = Millibar In H20 = Inches of waterkPa = Kilopascals In Hg = Inches of mercuryMPa = Megapascals mmHg = mm of mercuryConsult factory for other units of measure not listed
FIELD SELECTABLE STANDARD UNITS OF MEASURE
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Intrinsically Safe Pressure GaugeModel PI
DESCRIPTIONAs an in-process gauge or portable calibrator, the hand-held
Model PI delivers long-lasting, enhanced accuracy perfor-
mance. Accuracy of 0.2 % coupled with an enhanced resolution,
4½-digit display makes this unit an excellent transfer standard
for calibrating pressure measuring equipment.
The PI is rugged and features high/low pressure capture with a
field-adjustable update rate from three-to-ten times per second.
These units are manufactured from stainless steel and use sen-
sor technology which has no moving parts, requires little recali-
bration and has excellent overpressure tolerance. NEMA 4 rating
provides EMI and RFI protection. Units of measure are field-
selectable and the unit is offered with gage, absolute, vacuum,
or compound reference.
The Model PIW is powered by one or two common 9 V alkaline
batteries.
The PI Digital Gauges have the following complete Factory Mu-
tual Approved Classifications:
Class I: Gases and vapor
Class II: Combustible dust
Class III: Fibers
Intrinsically safe systems limit the thermal and electrical energy
to the hazardous area to help prevent ignition.
Division 1: present or likely to be present in normal operation
Division 2: not present in normal operation
Group A: Acetylene
Group B: Hydrogen
Group C: Acetaldehyde, Ethylene, Methyl Ether
Group D: Acetone, Gasoline, Methanol, Propane
Group E: Metal dust
Group F: Carbon dust
Group G: Grain dust
FEATURES• Highaccuracy:0.2%fullscale
• FactoryMutualapproved
• Rangesto10000psi-gage,absolute,vacuum,orcom-
pound
• Stainlesssteelconstruction
• On/offswitch
• CEcompliant
• 9Vbatterypower
• Optionalpressureports
• Optionalcarryingcaseandpanelmountingring
• High/lowcaptureandstore
• 4½-digitdisplaywith0.5inheight
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
2Honeywell•SensingandControl
Model PI
PERFORMANCE SPECIFICATIONS
Characteristic Measure
Accuracy 0.2%offullscaleBSFL
Pressure range, 0 psi to: 15,50,100,200,500,750,1000,1500,2000,5000,7500, 10000 psi
High and low capture Standard
Update speed 3 per sec
ENVIRONMENTAL SPECIFICATIONS
Characteristic Measure
Temperature, operating (standard)
-1°Cto71°C[30°Fto160°F]
Temperature, operating (optional)
-18°Cto82°C[0°Fto180°F]
ELECTRICAL SPECIFICATIONS
Characteristic Measure
Rating NEMA 4 (also provides temperature range of -18 °C to 82 °C [0°Fto180°F])
Power, Model PIW Oneortwo9Valkalinebatteries(in-cluded)
Power, Model PIV 11 Vdc to 32 Vdc @ 100 mA (3 ft cable included)
MECHANICAL SPECIFICATIONS
Characteristic Measure
Diameter 93,98mm[3.7in]
Display 4LCDdigits-12,7mm[0.5in]high
Pressure port 9/16-18UNF-2B-femalestraightthreadwithSAEspecJ514o-ringboss
Wetted parts Stainlesssteel
Case material Stainlesssteel
Lowbatteryindication Standard
Face membrane Tactile feedback raised buttons
Calibration data Storedonmemorychip
MOUNTINg DIMENSIONS AND CHARACTERISTICS
For reference only
ADDITIONAL SPECIFICATIONS
Pressure range (psi) Maximum safe over pressure (psi)1
Incremental display steps
0psito15psi=15 75 0.01
0psito50psi=50 250 0.05
0psito100psi=100 500 0.1
0psito200psi=200 1000 0.1
0psito500psi=500 1500 0.5
0psito750psi=750 1500 0.5
0psito1000psi=1K 2000 1
0psito1500psi=1.5K 3000 1
0psito2000psi=2K 4000 1
0psito5000psi=5K 7500 5
0psito7500psi=7.5K 12000 5
0psito10000psi=10K 15000 5
1 Maximum safe overpressure is the pressure which the unit can experience oc-casionally without the loss of accuracy or permanent damage
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Warranty. Honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship. Honeywell’s standard product warranty applies unless agreed to otherwise by Honeywell in writing; please refer to your order acknowledgement or consult your local sales office for specific warranty details. If warranted goods are returned to Honeywell during the period of coverage, Honeywell will repair or replace, at its option, without charge those items it finds defective. The foregoing is buyer’s sole remedy and is in lieu of all warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall Honeywell be liable for consequential, special, or indirect damages.
While we provide application assistance personally, through our literature and the Honeywell web site, it is up to the customer to determine the suitability of the product in the application.
Specificationsmaychangewithoutnotice.Theinformationwesupply is believed to be accurate and reliable as of this printing. However, we assume no responsibility for its use.
FormoreinformationaboutSensingandControlproducts,visitwww.honeywell.com/sensingorcall+1-815-235-6847Email inquiries to [email protected]
Failure to comply with these instructions could result in death or serious injury.
Notes
1.Thelimit/relaymodelsincludetwoLEDstatusindicatorsonfrontfaceand two form C relays (normally open, common, normally closed) that are rated at a maximum 24 Vdc/Vac at 1 A or 48 Vdc/Vac at 1/2 A.
W = Battery powered (9 v alkaline)*
* = Example
SERIESPI
PI W 200 G
POWER
PRESSURE RANGE (psi)
REFERENCEG = Gage (std) reads zero at atmosphere *A = Absolute (opt) reads zero at vacuum (15 psi or higher)V = Vacuum (opt) scaled in In Hg (15 psi or lower)C = Compound (opt) reads both positive & negative
(vacuum) pressure
ELECTRICAL CONNECTION
Z
15 = 0-1550 = 0-50100 = 0-100200 = 0-200*
500 = 0-500750 = 0-7501K = 0-10001.5K = 0-1500
2K = 0-20005K = 0-50007.5K = 0-750010K = 0-10000
Z = No electrical connection (Model PIW - 9 V battery)*Call factory for availability of other electrical connections and cable lengths.
Each gage has the following scaling built in for field selection:FIELD SELECTABLE STANDARD UNITS OF MEASURE
Bar = BarmBar = MillibarkPa = KilopascalsMPa = Megapascals
Ft H20 = Feet of waterIn H20 = Inches of waterIn Hg = Inches of mercurymmHg = mmof mercury
Consult factory for other units of measure not listed
NEMA (STANDARD)4 = NEMA 4
4
ORDER CODE
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Portable Pressure CalibratorsModels AC and JC
DESCRIPTIONConstructed with stainless steel wetted parts and totally por-
table, the JC and AC Series pressure calibrators can handle
many rugged applications and harsh environments. The circuitry
is designed to withstand dropping and is immune to electromag-
netic interference. The calibrators are fully battery powered (9 V)
so they are easily transportable from site to site.
This versatile pressure calibrator is available in two accuracies:
JC Series with 0.2 % accuracy and AC Series with 0.05 % ac-
curacy. The calibrators have a 4½-digit display for accurate and
easy readings. The high/low feature captures and holds both the
highest and lowest pressure reading. (Press clear or off to reset).
Operating temperatures are from -18 °C to 82 °C [0 °F to 180 °F].
The set includes the digital gauge, carrying case, NIST certifi-
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
2Honeywell•SensingandControl
Models AC and JC
PERFORMANCE SPECIFICATIONS
Characteristic Measure
Accuracy, JC Series 0.2 % of full scale
Accuracy, AC Series 0.05 % of full scale
ENVIRONMENTAL SPECIFICATIONS
Characteristic Measure
Temperature, operating (standard)
-1 °C to 71 °C [30 °F to 160 °F]
Temperature, operating (optional)
-18°Cto82°C[0°Fto180°F](NEMA4option required)AK only
ELECTRICAL SPECIFICATIONS
Characteristic Measure
Display, AC Series 4½ LCD digits, 0.5 in high
Display, JC Series 4 LCD digits, 0.5 in high
MECHANICAL SPECIFICATIONS
Characteristic Measure
Wettedparts Stainless steel
Case material Stainless steel
Highandlowcapture Standard
Calibration data Stored on memory chip
MOUNTINg DIMENSIONS AND CHARACTERISTICS
For reference only
ADDITIONAL SPECIFICATIONS
Incremental display steps
Pressure range (psi) Maximum safe over pressure (psi)1
Model JC
Model AC
0 psi to 1 psi = 1 (opt) 10 0.001 –
0 psi to 5 psi = 5 (opt) 25 0.005 –
0 psi to 15 psi = 15 75 0.01 0.005
0 psi to 30 psi = 30 150 0.02 –
0 psi to 50 psi = 50 250 0.05 0.01
0 psi to 100 psi = 100 500 0.1 0.02
0 psi to 200 psi = 200 1000 0.1 0.05
0 psi to 300 psi = 300 1200 0.2 –
0 psi to 500 psi = 500 1500 0.5 0.1
0 psi to 750 psi = 750 1500 0.5 0.2
0 psi to 1000 psi = 1K 2000 1 0.2
0 psi to 1500 psi = 1.5K 3000 1 0.5
0 psi to 2000 psi = 2K 4000 1 0.5
0 psi to 3000 psi = 3K 6000 2 –
0 psi to 5000 psi = 5K 7500 5 1
0 psi to 7500 psi = 7.5K 12000 5 2
0 psi to 10000 psi = 10K 15000 5 2
1Maximumsafeoverpressureisthepressurewhichtheunitcanexperienceoc-casionally without the loss of accuracy or permanent damage
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Warranty. Honeywellwarrantsgoodsofitsmanufactureasbeingfreeofdefectivematerialsandfaultyworkmanship.Honeywell’sstandardproductwarrantyappliesunlessagreedtootherwisebyHoneywellinwriting;pleaserefertoyourorderacknowledgementorconsultyourlocalsalesofficeforspecific warranty details. If warranted goods are returned to Honeywellduringtheperiodofcoverage,Honeywellwillrepairor replace, at its option, without charge those items it finds defective. The foregoing is buyer’s sole remedy and is in lieu of all warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall Honeywell be liable for consequential, special, or indirect damages.
Whileweprovideapplicationassistancepersonally,throughourliteratureandtheHoneywellwebsite,itisuptothecustomertodetermine the suitability of the product in the application.
Specifications may change without notice. The information we supply is believed to be accurate and reliable as of this printing. However,weassumenoresponsibilityforitsuse.
For more information about Sensing and Control products, visit www.honeywell.com/sensing or call [email protected]
REFERENCEG= Gage (std) reads zero at atmosphere *A= Absolute (opt) reads zero at vacuum (15 psi or higher)V= Vacuum (opt) scaled in In Hg (15 psi or lower)C= Compound (opt) reads both positive & negative
(vacuum) pressure
ELECTRICAL CONNECTIONZ = No electrical connection (Model JCW - 9 volt battery)*C = 3 foot cable (Model JCV)T = ac adapter (Model JCT)
Call factory for availability of other electrical connections and cable lengths.
These ordercodes are
used ONLY ifyou want specialunits of measure
and/orNEMA 4 rating.
( )Z
The following order codes are used ONLY if you want these options.
ORDER CODES
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Digital Force IndicatorModel LC
DESCRIPTIONThe Model LC digital force indicator is a highly portable force
measurement device. With its 9 V battery supply and compact
size the indicator can easily be carried to remote locations to
perform force measurement calibrations. The unit can measure
compression forces up to 50,000 lbs.
The peak capture feature allows the highest force reading taken
to be displayed with the push of a button. The remote location of
the load sensor minimizes the chance of damage to the elec-
tronic body of the gauge. The stainless steel construction of the
sensor and the indicator makes them often resistant to the occa-
sional mishandling than can occur in the field. Optional handles
are available for the load cell and gauge.
Each unit has a membrane face with raised buttons and tactile
feedback for setup and operation. The high, low, and clear but-
tons are easily accessible on this front membrane. Zero adjust-
ment and zero offset/tare functions are standard on each unit.
Calibration and setup parameters are stored on a memory chip
to protect from loss even when power is interrupted. Unauthor-
ized set ups and calibrations are also blocked with internal
security. Various combinations of the front panel buttons can be
de-activated.
FEATURES• Rangesto50000lb
• Compressionmeasurement
• High/lowforcecapture
• Zerooffset/tare
• NISTtraceable
• Customerrecalibration
• Optionalhandlesandpanelmountingring
• Optionalcarryingcase
• OptionalNEMA4rating
• Selectableengineeringunits
Model LC shown with optional handle.
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Warranty. Honeywellwarrantsgoodsofitsmanufactureasbeing free of defective materials and faulty workmanship. Honeywell’sstandardproductwarrantyappliesunlessagreedtootherwisebyHoneywellinwriting;pleaserefertoyourorder acknowledgement or consult your local sales office for specificwarrantydetails.IfwarrantedgoodsarereturnedtoHoneywellduringtheperiodofcoverage,Honeywellwillrepairor replace, at its option, without charge those items it finds defective. The foregoing is buyer’s sole remedy and is in lieu of all warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall Honeywell be liable for consequential, special, or indirect damages.
While we provide application assistance personally, through our literatureandtheHoneywellwebsite,itisuptothecustomertodetermine the suitability of the product in the application.
Specificationsmaychangewithoutnotice.Theinformationwesupply is believed to be accurate and reliable as of this printing. However,weassumenoresponsibilityforitsuse.
FormoreinformationaboutSensingandControlproducts,visitwww.honeywell.com/sensingorcall+1-815-235-6847Email inquiries to [email protected]
linearity, hysteresis and repeatability through zero.2. Consult factory for optional units of measure.3. Consult factory for optional electrical connectors and cable lengths.
ORDER gUIDE
SERIESLC=0.2%
POWERW=Battery powered (9 V alkaline)T=110 Vac adapter (included)V=11 Vdc to 32 Vdc (3 ft. cable)
ELECTRICAL CONNECTIONZ = No electrical connection C = 3 foot cableT = ac adapterCall factory for availability of other electrical connections and cable lengths.
UNITS OF MEASURE (Field Selectable)Note: lbs is standardn = NewtonKn = Kilonewtong = GramsKg = KilogramsConsult factory for other units of measure not listed
OPTIONAL NEMA 4 CONSTRUCTION4 = NEMA 4
standard
LC W 100 K Z ( )
This ordercode is
used ONLY ifyou want
NEMA 4 rating.
repeatability
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Digital Force IndicatorModel LK
DESCRIPTIONThe Model LK Digital Force Indicator is a highly portable force
measurement device. With its 9 V battery supply and compact
size the indicator can easily be carried to remote locations to
perform force measurement calibrations. The unit can measure
forces in tension and compression over ranges up to 10000 lb.
The peak capture feature allows the highest force reading taken
to be displayed with the push of a button.
The remote location of the load sensor minimizes the chance of
damage to the electronic body of the gauge. The stainless steel
construction of the sensor and the indicator also make them re-
sistant to the occasional mishandling than can occur in the field.
Optional handles are available for the load cell and gauge.
Each unit has a membrane face with raised buttons and tactile
feedback for setup and operation. The high, low, and clear but-
tons are easily accessible on this front membrane. Zero adjust-
ment and zero offset/tare functions are standard on each unit.
Calibration and setup parameters are stored on a memory chip
to protect from loss even when power is interrupted. Unauthor-
ized set ups and calibrations are also blocked with internal
security. Various combinations of the front panel buttons can be
de-activated.
FEATURES• Rangesto10000lb
• Tensionandcompressionmeasurement
• Highandlowforcecapture
• Zerooffset/tare
• NISTtraceable
• Optionalcarryingcaseandpanelmountingring
• OptionalNEMA4rating
• Fieldselectableengineeringunits(lb,N,kN,g,kg)
• Customerrecalibration
Model LK shown with optional handle. Visit our Web site for more information on optional handles.
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
2Honeywell•SensingandControl
Model LK
PERFORMANCE SPECIFICATIONS
Characteristic Measure
Range Seeadditionalspecificationstable
Accuracy 0.2 %1
Update speed 3persecond(selectableto10/second)
ENVIRONMENTAL SPECIFICATIONS
Characteristic Measure
Temperature, operating -1 °C to 71 °C [30 °F to 160 °F]
Rating NEMA2,std.(NEMA4optionalexceptmodelLKT)
ELECTRICAL SPECIFICATIONS
Characteristic Measure
Display LCD,41/2-digit,1,3cm[0.5in]high
Power supply, Model LKW 1or29-voltbatteries(included)
Power supply, Model LKT 110voltacadaptor@60Hz(included)
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Warranty. Honeywellwarrantsgoodsofitsmanufactureasbeing free of defective materials and faulty workmanship. Honeywell’sstandardproductwarrantyappliesunlessagreedtootherwisebyHoneywellinwriting;pleaserefertoyourorder acknowledgement or consult your local sales office for specific warranty details. If warranted goods are returned to Honeywellduringtheperiodofcoverage,Honeywellwillrepairor replace, at its option, without charge those items it finds defective. The foregoing is buyer’s sole remedy and is in lieu of all warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall Honeywell be liable for consequential, special, or indirect damages.
While we provide application assistance personally, through our literatureandtheHoneywellwebsite,itisuptothecustomertodetermine the suitability of the product in the application.
Specificationsmaychangewithoutnotice.Theinformationwesupply is believed to be accurate and reliable as of this printing. However,weassumenoresponsibilityforitsuse.
FormoreinformationaboutSensingandControlproducts,visitwww.honeywell.com/sensingorcall+1-815-235-6847Email inquiries to [email protected]
linearity, hysteresis and repeatability through zero.2. Consult factory for optional units of measure.3. Consult factory for optional electrical connectors and cable lengths.
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com