Top Banner
International Technical Seminar May 2011 Sl Presented by: CBNetworks Technical Support [email protected] http://www.cbnetworks.fr RADview-EMS Version 2.8
30

International Technical Seminar May 2011 Slide 1 Presented by: CBNetworks Technical Support [email protected] RADview-EMS.

Mar 30, 2015

Download

Documents

Naomi Bartlett
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: International Technical Seminar May 2011 Slide 1 Presented by: CBNetworks Technical Support support.technique@cbnetworks.fr  RADview-EMS.

International Technical Seminar May 2011 Slide 1

• Presented by:

• CBNetworks

• Technical Support

[email protected]

• http://www.cbnetworks.fr

RADview-EMS Version 2.8

Page 2: International Technical Seminar May 2011 Slide 1 Presented by: CBNetworks Technical Support support.technique@cbnetworks.fr  RADview-EMS.

RADview-EMS Update for PM2009 Slide 2http://www.cbnetworks.fr - [email protected]

• RADview Release Schedule

•RADview Value Proposition

•Network Scheme

•RADview-EMS Benefits & Features

•Turnkey system

•What’s new

•Business-Continuity Levels*

•Integrations

•Device Management

AgendaAgenda

What’s next… What’s next…

Page 3: International Technical Seminar May 2011 Slide 1 Presented by: CBNetworks Technical Support support.technique@cbnetworks.fr  RADview-EMS.

International Technical Seminar May 2011 Slide 3http://www.cbnetworks.fr - [email protected]

RADview-EMS is a unified carrier-class management platform for RAD devices and its subsidiary companies using a variety

of access channels as SNMPv1/3, HTTP/S, TFTP and Telnet/SSH. In addition, it features third-party device

monitoring capabilities

Page 4: International Technical Seminar May 2011 Slide 1 Presented by: CBNetworks Technical Support support.technique@cbnetworks.fr  RADview-EMS.

International Technical Seminar May 2011 Slide 4http://www.cbnetworks.fr - [email protected]

RADview-EMS Benefits & Features

●Turnkey system including hardware and software!

●Fully compliant with TMN standards

●Client/server architecture with multi-user support

●Interoperable with third-party NMS and leading OSS systems

●IBM Tivoli’s Netcool®/OMNIbus™ plug-in

●Minimize integrations costs associated with new NE additions

Benefits Benefits

●Ensures device health and congestion control

●Topology maps and network inventory

●Advanced FCAPS functionality

●Software & configuration management - CMDB

●Business continuity - High-Availability and Disaster Recovery

●Handover between operators

Key featuresKey features

Page 5: International Technical Seminar May 2011 Slide 1 Presented by: CBNetworks Technical Support support.technique@cbnetworks.fr  RADview-EMS.

International Technical Seminar May 2011 Slide 5http://www.cbnetworks.fr - [email protected]

Turnkey System – Plug & Play

●Based on Dell PowerEdge R610 systems

●Intel® Xeon® processor 5500 and 5600 series

●Reliable Dell hardware

●Customized for Entry/Medium/High level

●Windows Server®2008SP2 , installed

●Latest releases of RADview-EMS and Oracle, installed

●39 Months HW world wide warranty, NBD/RADcare

●Plug & Play

RADview-Server, windows based systemRADview-Server, windows based system

Page 6: International Technical Seminar May 2011 Slide 1 Presented by: CBNetworks Technical Support support.technique@cbnetworks.fr  RADview-EMS.

International Technical Seminar May 2011 Slide 6http://www.cbnetworks.fr - [email protected]

RADview-EMS v2.8What’s new…

● Configuration change history

● Scheduled jobs of all the above

● CLI script execution

● email notifications

Job ManagementJob Management

● Configuration management

● Software management

● Network baseline

● Startup vs. running

Configuration ManagementConfiguration Management

● Windows 7 32bit

● Windows 2008 server std 64bit

● Dynamic and static group management

GeneralGeneral

● Long term Y.1731 based reports

● Export to post processing systems

Performance Management P1.0 Performance Management P1.0

Page 7: International Technical Seminar May 2011 Slide 1 Presented by: CBNetworks Technical Support support.technique@cbnetworks.fr  RADview-EMS.

International Technical Seminar May 2011 Slide 7http://www.cbnetworks.fr - [email protected]

RADview-EMSConfiguration

• Provides Configuration change management per device– Tracking configuration changes– Tracking software update

• Browse and edit CLI configuration• Define Network/Device configuration baseline for easier rollback• Compare Startup-config vs. running-config • Table view of network elements enable sorting and filtering

Page 8: International Technical Seminar May 2011 Slide 1 Presented by: CBNetworks Technical Support support.technique@cbnetworks.fr  RADview-EMS.

International Technical Seminar May 2011 Slide 8http://www.cbnetworks.fr - [email protected]

RADview-EMSJobs

• Automation of network operations– Configuration backup– Software backup– Push CLI configuration updates

• Management of mass configuration changes• Task Scheduler • Reports and notification of jobs status• A TFTP server is required

Page 9: International Technical Seminar May 2011 Slide 1 Presented by: CBNetworks Technical Support support.technique@cbnetworks.fr  RADview-EMS.

RADview Update Dec 2010 Slide 9http://www.cbnetworks.fr - [email protected]

Supporting 3rd Party equipment

• 24/7 Connectivity Status Alerts• Displaying Generic Traps• GUI Cut Through to the device’s Web Management• Supporting CLI over Telnet/SSH• Manual discovery of NEs (Network Equipment)• Inventory management for NEs supporting RFC-4133 (Entity MIB)

Page 10: International Technical Seminar May 2011 Slide 1 Presented by: CBNetworks Technical Support support.technique@cbnetworks.fr  RADview-EMS.

International Technical Seminar May 2011 Slide 10http://www.cbnetworks.fr - [email protected]

RADview-EMS advanced FCAPS

Page 11: International Technical Seminar May 2011 Slide 1 Presented by: CBNetworks Technical Support support.technique@cbnetworks.fr  RADview-EMS.

International Technical Seminar May 2011 Slide 11http://www.cbnetworks.fr - [email protected]

RADview-EMSFCAPS

●Manage Event Log parameters

●Manage the way Events are displayed in the Event Browser

●Manage system response upon occurrence of specific Events.

●Trap Synchronization upon connection failure between RADview-EMS to NE (*supported devices only)

●Modify – Mask, Severity, Duplication, Forwarding, Threshold, Clearing, Formatting

●Manage Event Log parameters

●Manage the way Events are displayed in the Event Browser

●Manage system response upon occurrence of specific Events.

●Trap Synchronization upon connection failure between RADview-EMS to NE (*supported devices only)

●Modify – Mask, Severity, Duplication, Forwarding, Threshold, Clearing, Formatting

Fault Configuration Administration Performance Security

Page 12: International Technical Seminar May 2011 Slide 1 Presented by: CBNetworks Technical Support support.technique@cbnetworks.fr  RADview-EMS.

International Technical Seminar May 2011 Slide 12http://www.cbnetworks.fr - [email protected]

RADview-EMSFCAPS

●Realistic representation of the devices (shelf-view)

●Tracks configuration changes

●Configures, installs, and distributes software and configuration files across the network

●Viewing and/or modifying configuration (system, ports, and alarms)

●Enables viewing the diagnostics and status information

●Realistic representation of the devices (shelf-view)

●Tracks configuration changes

●Configures, installs, and distributes software and configuration files across the network

●Viewing and/or modifying configuration (system, ports, and alarms)

●Enables viewing the diagnostics and status information

ConfigurationFault Administration Performance Security

Shelf-ViewShelf-View

WebWeb

Page 13: International Technical Seminar May 2011 Slide 1 Presented by: CBNetworks Technical Support support.technique@cbnetworks.fr  RADview-EMS.

International Technical Seminar May 2011 Slide 13http://www.cbnetworks.fr - [email protected]

RADview-EMSFCAPS

●Audit trails for Security, System and Applications activities

●Tracks and log the shelf-view user activity

●Create and manage user accounts and groups

●Manage various server settings

●Audit trails for Security, System and Applications activities

●Tracks and log the shelf-view user activity

●Create and manage user accounts and groups

●Manage various server settings

AdministrationConfigurationFault Performance Security

Applications activitiesApplications activitiesSecurity logsSecurity logs

Page 14: International Technical Seminar May 2011 Slide 1 Presented by: CBNetworks Technical Support support.technique@cbnetworks.fr  RADview-EMS.

International Technical Seminar May 2011 Slide 14http://www.cbnetworks.fr - [email protected]

RADview-EMSFCAPS

●Real Time Performance Monitoring

●Monitors network performance (QoS, CoS)

●Current statistics (Real-time)

●Intervals statistics

●Reflects Agent statistics

●Long Term Performance Monitoring ● (*supported devices only)

●Performance Management Portal

●Real Time Performance Monitoring

●Monitors network performance (QoS, CoS)

●Current statistics (Real-time)

●Intervals statistics

●Reflects Agent statistics

●Long Term Performance Monitoring ● (*supported devices only)

●Performance Management Portal

PerformanceConfiguration AdministrationFault Security

StatisticsStatistics

Page 15: International Technical Seminar May 2011 Slide 1 Presented by: CBNetworks Technical Support support.technique@cbnetworks.fr  RADview-EMS.

International Technical Seminar May 2011 Slide 15http://www.cbnetworks.fr - [email protected]

Performance Management portal

• RADview-PM portal Collects, stores and presents KPIs (Key Performance Indicators) from RAD devices, fast and efficient!

• Accelerates the processing of new report definition • Immediate detection of service degradation allows service providers to take remedial actions to

quickly restore appropriate performance levels• Easily evaluate actual performance over time and compare it to SLA guarantees based on Y.1731

– Two-way Frame delay (ms) - Latency– Two-way Frame delay variation (ms) - Jitter– Packet Delivery (%) - (100% - Frame Loss ratio )– Availability (%)

• Additional Y.1731 KPIs reports are available

Page 16: International Technical Seminar May 2011 Slide 1 Presented by: CBNetworks Technical Support support.technique@cbnetworks.fr  RADview-EMS.

XXX 2010 Slide 16http://www.cbnetworks.fr - [email protected]

Frame delay, Frame delay variation

• Two-way Frame delay (ms) – Latency– Network Latency is the roundtrip time it takes for a packet to travel end-to-

end between two customer sites– Network Latency is measured in milliseconds and usually averaged on a

monthly basis• Frame Delay Variation (ms) - Jitter

– Jitter measures the average latency from packet-to-packet– Jitter is measured roundtrip in milliseconds and usually averaged on a

monthly basis

Frame Delay (ms) - LatencyFrame Delay Variation (ms) - Jitter

Page 17: International Technical Seminar May 2011 Slide 1 Presented by: CBNetworks Technical Support support.technique@cbnetworks.fr  RADview-EMS.

XXX 2010 Slide 17http://www.cbnetworks.fr - [email protected]

Packet Delivery/Frame Loss

• Packet Delivery (%) - (100% - Frame Loss ratio )– Packet Delivery is the percentage of packets delivered during

transmission between two customer sites– Packet Delivery is expressed as a ratio of delivered packets to

total packets passed and usually averaged on a monthly basis

Packet Delivery (%)

Page 18: International Technical Seminar May 2011 Slide 1 Presented by: CBNetworks Technical Support support.technique@cbnetworks.fr  RADview-EMS.

XXX 2010 Slide 18http://www.cbnetworks.fr - [email protected]

Availability

• Availability (%) – Availability is the ability to transmit data over the Ethernet

network– Availability is calculated by dividing the average number of

minutes that the Services are available by the total number of minutes in each calendar month and multiplying by 100

Availability (%)

Page 19: International Technical Seminar May 2011 Slide 1 Presented by: CBNetworks Technical Support support.technique@cbnetworks.fr  RADview-EMS.

XXX 2010 Slide 19http://www.cbnetworks.fr - [email protected]

Collection and Scalability

• RADview-Collector* initiates an SNMP command to the NTUs to push the performance counter data every round hour or 15 minutes via TFTP

• The collector is responsible for the retrieval of lost data resulting from connection failure upon re-establishing the connection up to 24 hours back

• Performance counters are being compressed to minimize management traffic over the network

• Date is stored in an Oracle database and later on can be exported to CSV ASCII files or by API for OSS post processing systems

• Can manage up to 1000 nodes per server**

RADview-Collector

Page 20: International Technical Seminar May 2011 Slide 1 Presented by: CBNetworks Technical Support support.technique@cbnetworks.fr  RADview-EMS.

International Technical Seminar May 2011 Slide 20http://www.cbnetworks.fr - [email protected]

RADview-EMSFCAPS

●View and manage EMS Security profiles in a graphical interface

●Create and edit security profiles

●Create Common/Private view profiles per user/group

●Collects accounting data and generates network usage reports

●Define password policies

●View and manage EMS Security profiles in a graphical interface

●Create and edit security profiles

●Create Common/Private view profiles per user/group

●Collects accounting data and generates network usage reports

●Define password policies

SecurityConfiguration Administration PerformanceFault

Security profilesSecurity profiles Password policyPassword policy

Page 21: International Technical Seminar May 2011 Slide 1 Presented by: CBNetworks Technical Support support.technique@cbnetworks.fr  RADview-EMS.

International Technical Seminar May 2011 Slide 21http://www.cbnetworks.fr - [email protected]

Business-Continuity Levels

Page 22: International Technical Seminar May 2011 Slide 1 Presented by: CBNetworks Technical Support support.technique@cbnetworks.fr  RADview-EMS.

International Technical Seminar May 2011 Slide 22http://www.cbnetworks.fr - [email protected]

●Based on RADview-EMS/<Win&Unix>Pack1/R backup and restore tool●Backup file can be saved anywhere ●Restore from backed-up files – RPO can be very long

Business-Continuity Options

●Geographically separated NMS servers that are replicated constantly●RPO and RTO are short●Manual switchover

Disaster Recovery (DR) 1+1Disaster Recovery (DR) 1+1

●Local clustering - RPO and RTO are short●Immediate recovery in the event of OS or HW failure in a single site ●Automatic failover

High Availability (HA) ClusterHigh Availability (HA) Cluster

Primary Primary

sitesiteBackup Backup

sitesiteBackup and RestoreBackup and Restore

Page 23: International Technical Seminar May 2011 Slide 1 Presented by: CBNetworks Technical Support support.technique@cbnetworks.fr  RADview-EMS.

International Technical Seminar May 2011 Slide 23http://www.cbnetworks.fr - [email protected]

Backup and Restore (Cold standby)

• Based on RADview-EMS/<PC&Unix>Pack1/R backup and restore tool• Cost effective – sold without hardware or additional software • RPO is long – since last back-up• Completely manual operation

DR siteDR sitePrimary SitePrimary Site

EMS-Client X-Client Client

Operators

OSS

ActiveServer

Standby

Server

Run a backup process

Run a restore process

Transfer the file

Page 24: International Technical Seminar May 2011 Slide 1 Presented by: CBNetworks Technical Support support.technique@cbnetworks.fr  RADview-EMS.

International Technical Seminar May 2011 Slide 24http://www.cbnetworks.fr - [email protected]

High Availability (HA) Cluster

!

Local Clustering Local Clustering

EMS-Client X-Client Client

Operators

OSS

• Turnkey system including server hardware, Cluster and RADview software

• RPO and RTO are short

• Instant automatic failover

• Clients can keep working after few seconds

• Good for large NOC with dozens of clients connected to RADview simultaneously

Page 25: International Technical Seminar May 2011 Slide 1 Presented by: CBNetworks Technical Support support.technique@cbnetworks.fr  RADview-EMS.

International Technical Seminar May 2011 Slide 25http://www.cbnetworks.fr - [email protected]

Disaster Recovery (DR) 1+1

• Turnkey system including server hardware, replication and RADview software• RPO and RTO are short – storage is being replicated constantly• Semi automatic switchover by push button, good for disaster recovery scenarios• Clients are being shifted to DR site upon activation

Network Outage

Production

Data

Secondary

Data

DR siteDR sitePrimary SitePrimary Site

EMS-Client X-Client Client

Operators

OSS

ActiveServer

Standby

Server

Page 26: International Technical Seminar May 2011 Slide 1 Presented by: CBNetworks Technical Support support.technique@cbnetworks.fr  RADview-EMS.

International Technical Seminar May 2011 Slide 26http://www.cbnetworks.fr - [email protected]

Integrations

Page 27: International Technical Seminar May 2011 Slide 1 Presented by: CBNetworks Technical Support support.technique@cbnetworks.fr  RADview-EMS.

RADview Update Dec 2010 Slide 27http://www.cbnetworks.fr - [email protected]

●RADview-EMS standalone software only●Includes 300ENW, 5 Clients

RADview Packages

●RADview-EMS system based on Dell R610, Windows server 2008SP2●Includes 2 servers in replication (DR) mode, 300xRV-LIC/ENW/R, 5

Clients and 3 Years worldwide HW warranty

Pack 3 - Turnkey system (DR mode)Pack 3 - Turnkey system (DR mode)

●RADview-EMS system based on Dell R610, Windows server 2008SP2●Includes 2 servers and external storage in local clustering (HA) mode,

300ENW/R, 5 Clients and 3 Years worldwide HW warranty

Pack 4 - Turnkey system (HA Mode)Pack 4 - Turnkey system (HA Mode)

●RADview-EMS server based on Dell R610, Windows server 2008SP2 ●Includes one server, 300ENW, 5 Clients and 3 Years worldwide HW

warranty

Pack 2 - Turnkey system (Regular) Pack 2 - Turnkey system (Regular)

Pack 1 – Software onlyPack 1 – Software only

Page 28: International Technical Seminar May 2011 Slide 1 Presented by: CBNetworks Technical Support support.technique@cbnetworks.fr  RADview-EMS.

RADview Update Dec 2010 Slide 28http://www.cbnetworks.fr - [email protected]

Device Management

• RAD products support the following management capabilities

Device ManagementDevice Management

Page 29: International Technical Seminar May 2011 Slide 1 Presented by: CBNetworks Technical Support support.technique@cbnetworks.fr  RADview-EMS.

International Technical Seminar May 2011 Slide 29http://www.cbnetworks.fr - [email protected]

Summary

• RADview Value Proposition• Network Scheme• RADview-EMS Benefits & Features• Turnkey system• What’s new• Business-Continuity Levels• Integrations• Device Management

Page 30: International Technical Seminar May 2011 Slide 1 Presented by: CBNetworks Technical Support support.technique@cbnetworks.fr  RADview-EMS.

International Technical Seminar May 2011 Slide 30

Thank You For Your Attention

• Technical Support

[email protected]

• http://www.cbnetworks.fr