Top Banner
Internal use only Daikin Altherma HT
70

Internal use only Daikin Altherma HT. 2 10-Oct-14 Internal use only Name: J. Logghe Dept: New Business Table of contents 1. Product concept 2. Product.

Apr 01, 2015

Download

Documents

Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: Internal use only Daikin Altherma HT. 2 10-Oct-14 Internal use only Name: J. Logghe Dept: New Business Table of contents 1. Product concept 2. Product.

Internal use only

Daikin Altherma HT

Page 2: Internal use only Daikin Altherma HT. 2 10-Oct-14 Internal use only Name: J. Logghe Dept: New Business Table of contents 1. Product concept 2. Product.

2Apr 11, 2023

Internal use only

Name: J. Logghe • Dept: New Business

Table of contents

1. Product concept

2. Product features

4. Product line-up

4. Nomenclature

5. Specifications

6. Summary

3. Applications

Page 3: Internal use only Daikin Altherma HT. 2 10-Oct-14 Internal use only Name: J. Logghe Dept: New Business Table of contents 1. Product concept 2. Product.

3Apr 11, 2023

Internal use only

Name: J. Logghe • Dept: New Business

Product concept

Cascade system: 2 refrigerant cycles with 2 inverter compressors

Leaving water temperatures possible up to 80°C, ambient temperature down to -20°C

Heating capacities: 11, 14 and 16kW (single and three phase)

down to -20°C up to

80°C

1 2 3

IndoorOutdoor

Page 4: Internal use only Daikin Altherma HT. 2 10-Oct-14 Internal use only Name: J. Logghe Dept: New Business Table of contents 1. Product concept 2. Product.

4Apr 11, 2023

Internal use only

Name: J. Logghe • Dept: New Business

Product concept: 3 heat exchangers

Outdoor unit evaporator: air – R410A energy exchange

First plate heat exchanger: R410A – R134a energy transfer (indoor unit)

Intermediate condense temperature

Second stage condense temperature

2

3

1

2

3 Second plate heat exchanger: R134a – H2O energy exchange, allowing LWT up to 80°C (indoor unit)

R134a

R410A

On thermodynamic efforts only, no electrical heater

1

Symbolic graph

Page 5: Internal use only Daikin Altherma HT. 2 10-Oct-14 Internal use only Name: J. Logghe Dept: New Business Table of contents 1. Product concept 2. Product.

5Apr 11, 2023

Internal use only

Name: J. Logghe • Dept: New Business

Product concept: target market

Typical supply temperature areas of different heat generators

(VL°C)

20 30 40 50 60 70 80 90

Daikin Altherma

Condensing Boiler

LT-Boiler

Standard Boiler

LT radiators

Floor heating

Fan convectors

HT radiators

TARGET MARKET

Daikin Altherma Split + Monobloc

Daikin Altherma HT

Page 6: Internal use only Daikin Altherma HT. 2 10-Oct-14 Internal use only Name: J. Logghe Dept: New Business Table of contents 1. Product concept 2. Product.

6Apr 11, 2023

Internal use only

Name: J. Logghe • Dept: New Business

Product concept: target market

Outdoor unit Indoor unit (DHW tank included) High temperature radiators and domestic hot water

Leaving water temperatures possible up to 80°C which makes it the perfect solution in combination with existing high temperature radiators

Refurbishment market

Very efficient way to heat up the DHW, no electrical heater required

Page 7: Internal use only Daikin Altherma HT. 2 10-Oct-14 Internal use only Name: J. Logghe Dept: New Business Table of contents 1. Product concept 2. Product.

7Apr 11, 2023

Internal use only

Name: J. Logghe • Dept: New Business

Product concept: target market

60°C

Max TLWC (°C)

80°C 90°C65°C25°C

100%

Cover more than 90% of the refurbishment demand

Demand coverage of refurbishment market (%)

With a maximum TLWC of 80°C, the Daikin Altherma HT can cover the biggest part of the refurbishment market

> 90%

Page 8: Internal use only Daikin Altherma HT. 2 10-Oct-14 Internal use only Name: J. Logghe Dept: New Business Table of contents 1. Product concept 2. Product.

8Apr 11, 2023

Internal use only

Name: J. Logghe • Dept: New Business

Table of contents

1. Product concept

2. Product features

4. Product line-up

4. Nomenclature

5. Specifications

6. Summary

3. Applications

Page 9: Internal use only Daikin Altherma HT. 2 10-Oct-14 Internal use only Name: J. Logghe Dept: New Business Table of contents 1. Product concept 2. Product.

9Apr 11, 2023

Internal use only

Name: J. Logghe • Dept: New Business

Product features: indoor unit

Hydrobox (small footprint)

Easy installation thanks to the complete indoor unit with DHW tank and hydraulic components already included

DHW tank: 200L or 260L

695

mm

600 mm

2010 mm

2285 mm

705 mm

Page 10: Internal use only Daikin Altherma HT. 2 10-Oct-14 Internal use only Name: J. Logghe Dept: New Business Table of contents 1. Product concept 2. Product.

10Apr 11, 2023

Internal use only

Name: J. Logghe • Dept: New Business

Product features: indoor unit

If necessary, the DHW tank can also be installed next to the hydrobox

Option kit for standalone tank EKFMAHTA includes:

1) top plate

2) adaptors (to go from quick couplers to screw connections)

3) piping between the screw connections (max distance between hydrobox

and DHW tank is 25cm, longer pipes are field supply)

200L

260L

1335 mm

1580 mm

Page 11: Internal use only Daikin Altherma HT. 2 10-Oct-14 Internal use only Name: J. Logghe Dept: New Business Table of contents 1. Product concept 2. Product.

11Apr 11, 2023

Internal use only

Name: J. Logghe • Dept: New Business

Product features: hydrobox

Heat exchanger

R134a ↔ H2O

Heat exchanger

R410A ↔ R134a

Compressor R134a

Expansion vessel (12L)

Air purge

Manometer

Pump (DC-inverter to maintain fixed ΔT)

Page 12: Internal use only Daikin Altherma HT. 2 10-Oct-14 Internal use only Name: J. Logghe Dept: New Business Table of contents 1. Product concept 2. Product.

12Apr 11, 2023

Internal use only

Name: J. Logghe • Dept: New Business

Product features: hydrobox

3 way valve located in hydrobox (only with DHW tank)

Page 13: Internal use only Daikin Altherma HT. 2 10-Oct-14 Internal use only Name: J. Logghe Dept: New Business Table of contents 1. Product concept 2. Product.

13Apr 11, 2023

Internal use only

Name: J. Logghe • Dept: New Business

Product features: PCB plate

Switchbox is located behind the front plate of the hydrobox

Page 14: Internal use only Daikin Altherma HT. 2 10-Oct-14 Internal use only Name: J. Logghe Dept: New Business Table of contents 1. Product concept 2. Product.

14Apr 11, 2023

Internal use only

Name: J. Logghe • Dept: New Business

Product features: DHW tank

Standard UK model Special: TBC

200 L 260 LDHW tank line-up:

6 models

Product line-up DHW tank

Option kit for UK: EKUHWHTA

= other material name than on Daikin Altherma Split and Monobloc

Page 15: Internal use only Daikin Altherma HT. 2 10-Oct-14 Internal use only Name: J. Logghe Dept: New Business Table of contents 1. Product concept 2. Product.

15Apr 11, 2023

Internal use only

Name: J. Logghe • Dept: New Business

Product features: DHW tank

Main parts DHW tank

Page 16: Internal use only Daikin Altherma HT. 2 10-Oct-14 Internal use only Name: J. Logghe Dept: New Business Table of contents 1. Product concept 2. Product.

16Apr 11, 2023

Internal use only

Name: J. Logghe • Dept: New Business

Product features: DHW tank

Naked tank lay-out Fully assembled (at factory) Front panels detached

Standard tank

Top plate from Hydrobox or EKFMAHTA

Page 17: Internal use only Daikin Altherma HT. 2 10-Oct-14 Internal use only Name: J. Logghe Dept: New Business Table of contents 1. Product concept 2. Product.

17Apr 11, 2023

Internal use only

Name: J. Logghe • Dept: New Business

Product features: DHW tank

UK tank: standard tank + factory fitted T&p valve

Factory fitted T&p valve

Page 18: Internal use only Daikin Altherma HT. 2 10-Oct-14 Internal use only Name: J. Logghe Dept: New Business Table of contents 1. Product concept 2. Product.

18Apr 11, 2023

Internal use only

Name: J. Logghe • Dept: New Business

>3

00

mm

<500 mm

6

7

HC

Product features: DHW tank

Option kit on UK tank: EKUHWHTA

4

7

78

7

Pressure reducing valve

Expansion relief valve

Tundish

Expansion vessel (18L)

Tundish

Page 19: Internal use only Daikin Altherma HT. 2 10-Oct-14 Internal use only Name: J. Logghe Dept: New Business Table of contents 1. Product concept 2. Product.

19Apr 11, 2023

Internal use only

Name: J. Logghe • Dept: New Business

Product features: DHW tank

Special tank: standard tank + passivated + service opening

Service hole: requirement for Switzerland and Germany

Cleaning opening of 120 mm at the lowest third part of the tank

Passivated tank: requirement for Danmark

TBC

Page 20: Internal use only Daikin Altherma HT. 2 10-Oct-14 Internal use only Name: J. Logghe Dept: New Business Table of contents 1. Product concept 2. Product.

20Apr 11, 2023

Internal use only

Name: J. Logghe • Dept: New Business

Product features: DHW tank

Tank performance: heat-up time (calculations)

Size of the coil: length of 23m, surface area of 1,56m², internal coil volume of 7,5L

Calculation example: ERSQ016AAV1 with EKHTS200 tank

Altherma HT (200l coil 1.56 m^2)

0

10

20

30

40

50

60

70

80

90

0 1000 2000 3000 4000 5000 6000 7000 8000 9000 10000 Time(s)

T(°C)

0

2000

4000

6000

8000

10000

12000

14000

16000

18000

20000

Q(W)

T_in

T_tank

T_out

Q

Up to a DHW temperature of 70°C, the part load capacity of the heat pump can still be exchanged to the DHW with the 1,56m² coil

Page 21: Internal use only Daikin Altherma HT. 2 10-Oct-14 Internal use only Name: J. Logghe Dept: New Business Table of contents 1. Product concept 2. Product.

21Apr 11, 2023

Internal use only

Name: J. Logghe • Dept: New Business

Product features: DHW tank

Tank performance: heat losses

200 l 260 l

Total capacity (L) 201 258

Actual capacity (L) 193,5 250,5

Heat loss (kWh/24h) at dT = 45°C

1.2 1.5

Heat loss (W) at dT = 45°C 50 62,5

Max. temperature (°C) 75 75

Total capacity = internal volume of the tank (= effective water volume + coil volume

Actual capacity = effective water volume inside the tank

Page 22: Internal use only Daikin Altherma HT. 2 10-Oct-14 Internal use only Name: J. Logghe Dept: New Business Table of contents 1. Product concept 2. Product.

22Apr 11, 2023

Internal use only

Name: J. Logghe • Dept: New Business

Product features: DHW tank

Tank performance: heat-up time and reheat time

Page 23: Internal use only Daikin Altherma HT. 2 10-Oct-14 Internal use only Name: J. Logghe Dept: New Business Table of contents 1. Product concept 2. Product.

23Apr 11, 2023

Internal use only

Name: J. Logghe • Dept: New Business

Product features: DHW tank

Different possibilities to produce DHW

Reheat operation: has always priority above space heating

Storage operation - automatic operation (night and/or day timer)- manual operation

Storage operation has priority above space heating, taking in account:- min/max running timers- smart logic function

Disinfection operation: has always priority above space heating

Page 24: Internal use only Daikin Altherma HT. 2 10-Oct-14 Internal use only Name: J. Logghe Dept: New Business Table of contents 1. Product concept 2. Product.

24Apr 11, 2023

Internal use only

Name: J. Logghe • Dept: New Business

Product features: DHW tank

Tank performance: maximum volume of usable hot water

Page 25: Internal use only Daikin Altherma HT. 2 10-Oct-14 Internal use only Name: J. Logghe Dept: New Business Table of contents 1. Product concept 2. Product.

25Apr 11, 2023

Internal use only

Name: J. Logghe • Dept: New Business

Product features: User interface

The same controller as supplied with indoor unit can be

mounted parallel or on other location. If 2 controllers are

installed, the installer needs to select 1 master & 1 slave.

User interface is mounted separately from indoor unit

User interface can be used as a modulating room thermostat

Optimized efficiency due to feedback of room temperature

Optimized changeover from DHW heating to space heating

Option kit: Remote user interface EKRUAHTA

Not possible to use both user interfaces as a multi zone application (e.g. one in living room, other one in the kitchen)

Page 26: Internal use only Daikin Altherma HT. 2 10-Oct-14 Internal use only Name: J. Logghe Dept: New Business Table of contents 1. Product concept 2. Product.

26Apr 11, 2023

Internal use only

Name: J. Logghe • Dept: New Business

Product features: Control possibilities

1

2

3 Thermostatic valve

Weather dependent floating setpoint: TLWC = f(Ta)

Thermostat control: user interface as room thermostat or normal room thermostat

ROOM 1master room (eg living room)

ROOM 2 ROOM 3

thermostatic valve: temperature control by liquid or gas expansion

Tl

radiator valve

T

Ta

ON/OFF-valvemanual control

1 2 3 4 5 6 settings

20°C

27°C7°C

room thermostat

temperature control

TLWC

Weather dependent floating setpoint

1

Ta

2

3

Page 27: Internal use only Daikin Altherma HT. 2 10-Oct-14 Internal use only Name: J. Logghe Dept: New Business Table of contents 1. Product concept 2. Product.

27Apr 11, 2023

Internal use only

Name: J. Logghe • Dept: New Business

Product features: Full H/P tariff

Equipment allows for connection to a benefit kWh rate power supply

New on Daikin Altherma HT

Controllers are connected to a normal power connection

When the benefit kWh rate power supply is interrupted, the compressor will stop operating, but there is no chance that the settings will be lost during longer power shutdowns

Page 28: Internal use only Daikin Altherma HT. 2 10-Oct-14 Internal use only Name: J. Logghe Dept: New Business Table of contents 1. Product concept 2. Product.

28Apr 11, 2023

Internal use only

Name: J. Logghe • Dept: New Business

Product features: zone 2 and zone 3 model

Freeze protection for outdoor unit: bottom plate heater

• A bottom plate heater will be standard in areas where low ambient temperatures can

occur together with high humidity conditions (zone 2 model ERRQ), in other countries a

bottom plate heater is available as an option (zone 3 model ERSQ).

• To protect the outdoor unit against severe ice build-up on the air-cooled coil

New on Daikin Altherma HT

The bottom plate heater has no external thermostat, but is controlled by the PCB of the indoor unit

3°C

5°CTa

Time

ON/OFF depending on:- Hysteresis: 3° < Ta < 5°- Unit operation status

Page 29: Internal use only Daikin Altherma HT. 2 10-Oct-14 Internal use only Name: J. Logghe Dept: New Business Table of contents 1. Product concept 2. Product.

29Apr 11, 2023

Internal use only

Name: J. Logghe • Dept: New Business

Product features: zone 2 and zone 3 model

Zone 2 + 3 > 85% of the heating

market

zone 3

zone 2

‘mild’ climate

‘cold’ climate Zone 2 model ERRQ:

Outdoor unit is equipped with a

Bottom plate heater

Zone 3 model ERSQ:

Bottom plate heater as an option

Zone 2 countries:

Only access to zone 2 models

Zone 3 and 4 countries:

Access to both models

RU, FIN

POL, GER, CE, Nor-EU (except FIN)

SP, IT, GR, TKY, UK, IRL, BEL, NL, FR

POR, ME, SA

centrral-AFR

ZONE TEMP.-30 ~ -20°C

COUNTRIES

-10 ~ 0°C

0 ~ 10°C

10 ~ 20°C

-20 ~ -10°C

1

2

3

4

5

Page 30: Internal use only Daikin Altherma HT. 2 10-Oct-14 Internal use only Name: J. Logghe Dept: New Business Table of contents 1. Product concept 2. Product.

30Apr 11, 2023

Internal use only

Name: J. Logghe • Dept: New Business

Table of contents

1. Product concept

2. Product features

4. Product line-up

4. Nomenclature

5. Specifications

6. Summary

3. Applications

Page 31: Internal use only Daikin Altherma HT. 2 10-Oct-14 Internal use only Name: J. Logghe Dept: New Business Table of contents 1. Product concept 2. Product.

31Apr 11, 2023

Internal use only

Name: J. Logghe • Dept: New Business

Space heating & DHW heating: 1 RC in living room

Applications examples

- No frequent start/stop of the unit and no big temperature fluctuations in the room

- Smart logic functionality which controls the combined space heating and DHW demand

Page 32: Internal use only Daikin Altherma HT. 2 10-Oct-14 Internal use only Name: J. Logghe Dept: New Business Table of contents 1. Product concept 2. Product.

32Apr 11, 2023

Internal use only

Name: J. Logghe • Dept: New Business

Applications examples

Space heating & DHW heating: 1 RC in living room, 1RC near the unit

The main remote controller (C1) is installed in the living room and can access all settings (master). The second remote controller (C2) can not access schedule and parameter settings (slave)

Page 33: Internal use only Daikin Altherma HT. 2 10-Oct-14 Internal use only Name: J. Logghe Dept: New Business Table of contents 1. Product concept 2. Product.

33Apr 11, 2023

Internal use only

Name: J. Logghe • Dept: New Business

Applications examples

Space heating & DHW heating: 1 external RT in living room, 1RC near the unit

There is only room thermostat on/off control. There is no smart logic functionality for space heating, DHW operation is performed according to the min/max timer operation

Daikin can not guarantee neither good operation nor reliability of the system, if a non-Daikin thermostat is used (= NO WARRANTY)

Page 34: Internal use only Daikin Altherma HT. 2 10-Oct-14 Internal use only Name: J. Logghe Dept: New Business Table of contents 1. Product concept 2. Product.

34Apr 11, 2023

Internal use only

Name: J. Logghe • Dept: New Business

Applications examples

Multiple setpoint control

Space 0: Radiators

Tsetpoint = 65°C

Space 1: Fan Coil Units

Tsetpoint = 45°C

Space 2: Under Floor Heating

Tsetpoint = 35°C

If there is a heat demand from space 0, the leaving water temperature delivered by the Daikin system is too high

A Temperature reducing device (TRD) is required for space 1 and 2, to lower the water temperature

- The TRD’s are field supply

- Control of the TRD’s is not done by the heat pump system

- Operation and configuration of the TRD’s is the responsibility of the installer

Daikin only offers the possibility to have multiple set points

When TRD’s are installed, the system can be configured to use multiple water set point.

UFH

65°C

35°C

30°C

30°C

30°C

TRD

Page 35: Internal use only Daikin Altherma HT. 2 10-Oct-14 Internal use only Name: J. Logghe Dept: New Business Table of contents 1. Product concept 2. Product.

35Apr 11, 2023

Internal use only

Name: J. Logghe • Dept: New Business

Applications examples

Space heating & DHW heating: Radiators and UFH, DHW tank parallel

The DHW tank is installed in parallel with the TRD’s. This allows operating the unit in space heating and DHW heating simultaneously

- 2 space heating setpoints

- 1 DHW setpoint

no 3-way valve

Page 36: Internal use only Daikin Altherma HT. 2 10-Oct-14 Internal use only Name: J. Logghe Dept: New Business Table of contents 1. Product concept 2. Product.

36Apr 11, 2023

Internal use only

Name: J. Logghe • Dept: New Business

Applications examples

Space heating & DHW heating: Radiators / FCU / UFH, DHW tank in a separate circuit

The DHW tank is installed in a separate circuit of the TRD’s. This configuration does not allow simultaneous DHW heating and space heating operation.

- 3 space heating setpoints

- 1 DHW setpoint [b-03]

Page 37: Internal use only Daikin Altherma HT. 2 10-Oct-14 Internal use only Name: J. Logghe Dept: New Business Table of contents 1. Product concept 2. Product.

37Apr 11, 2023

Internal use only

Name: J. Logghe • Dept: New Business

Applications examples

Space heating & DHW heating: space heating with an auxiliary boiler (alternating operation)

- Bivalent operation is only possible for space heating operation, not for DHW heating operation

- An auxiliary contact decides whether either the Daikin unit or the boiler will operate (e.g. outdoor thermostat, electricity tariff contact, manually operated contact)

Page 38: Internal use only Daikin Altherma HT. 2 10-Oct-14 Internal use only Name: J. Logghe Dept: New Business Table of contents 1. Product concept 2. Product.

38Apr 11, 2023

Internal use only

Name: J. Logghe • Dept: New Business

Table of contents

1. Product concept

2. Product features

4. Product line-up

4. Nomenclature

5. Specifications

6. Summary

3. Applications

Page 39: Internal use only Daikin Altherma HT. 2 10-Oct-14 Internal use only Name: J. Logghe Dept: New Business Table of contents 1. Product concept 2. Product.

39Apr 11, 2023

Internal use only

Name: J. Logghe • Dept: New Business

Product line-up

Single Phase Three Phase

11kW 14kW 16kW

Zone 2 Zone 3 Outdoor unit line-up:

12 models

Single Phase Three Phase

11kW 14kW 16kW

Indoor unit line-up:

6 models

Standard UK model Special: TBC

200 L 260 LDHW tank line-up:

6 models

Page 40: Internal use only Daikin Altherma HT. 2 10-Oct-14 Internal use only Name: J. Logghe Dept: New Business Table of contents 1. Product concept 2. Product.

40Apr 11, 2023

Internal use only

Name: J. Logghe • Dept: New Business

Product line-up: standard equipment

Page 41: Internal use only Daikin Altherma HT. 2 10-Oct-14 Internal use only Name: J. Logghe Dept: New Business Table of contents 1. Product concept 2. Product.

41Apr 11, 2023

Internal use only

Name: J. Logghe • Dept: New Business

Product line-up: optional equipment

Optional kits connected to the indoor unit

Demand PCB: required to be able to connect room thermostat or BUH kit and for multiple setpoint control (see service presentation)

Page 42: Internal use only Daikin Altherma HT. 2 10-Oct-14 Internal use only Name: J. Logghe Dept: New Business Table of contents 1. Product concept 2. Product.

42Apr 11, 2023

Internal use only

Name: J. Logghe • Dept: New Business

Product line-up: Combination table

Combination table of outdoor and indoor unit

Page 43: Internal use only Daikin Altherma HT. 2 10-Oct-14 Internal use only Name: J. Logghe Dept: New Business Table of contents 1. Product concept 2. Product.

43Apr 11, 2023

Internal use only

Name: J. Logghe • Dept: New Business

Product line-up: optional equipment

Optional kits connected to the outdoor unit

If a bottom plate heater is installed (EKBPHTH16A), than it’s not allowed to install the drain plug kit

A bottom plate heater is standard, the drain plug kit can not be installed

Page 44: Internal use only Daikin Altherma HT. 2 10-Oct-14 Internal use only Name: J. Logghe Dept: New Business Table of contents 1. Product concept 2. Product.

44Apr 11, 2023

Internal use only

Name: J. Logghe • Dept: New Business

Product line-up: optional equipment

Optional kits connected to the DHW tank

Page 45: Internal use only Daikin Altherma HT. 2 10-Oct-14 Internal use only Name: J. Logghe Dept: New Business Table of contents 1. Product concept 2. Product.

45Apr 11, 2023

Internal use only

Name: J. Logghe • Dept: New Business

Table of contents

1. Product concept

2. Product features

4. Product line-up

4. Nomenclature

5. Specifications

6. Summary

3. Applications

Page 46: Internal use only Daikin Altherma HT. 2 10-Oct-14 Internal use only Name: J. Logghe Dept: New Business Table of contents 1. Product concept 2. Product.

46Apr 11, 2023

Internal use only

Name: J. Logghe • Dept: New Business

Nomenclature: Outdoor unit

E R S 011 AA V1

E: European model

Temperature zone indication

S: Ambient zone 3

R: Ambient zone 2

Refrigerant code

Q: R410A

Capacity index kW

Major model change

Minor model change

Power supply code

V1: 1~ / 220-240V / 50Hz

Y1: 3~ / 380-415V / 50Hz

Q

R: outdoor model

Page 47: Internal use only Daikin Altherma HT. 2 10-Oct-14 Internal use only Name: J. Logghe Dept: New Business Table of contents 1. Product concept 2. Product.

47Apr 11, 2023

Internal use only

Name: J. Logghe • Dept: New Business

Nomenclature: Indoor unit

E K HBR 011 AA V1

E: European model

HBR: hydrobox H/O HT

Capacity index kW

Major model change

Minor model change

Power supply code

V1: 1~ / 220-240V / 50Hz

Y1: 3~ / 380-415V / 50Hz

D

K: indoor model

Refrigerant codeD: R134a

Page 48: Internal use only Daikin Altherma HT. 2 10-Oct-14 Internal use only Name: J. Logghe Dept: New Business Table of contents 1. Product concept 2. Product.

48Apr 11, 2023

Internal use only

Name: J. Logghe • Dept: New Business

Nomenclature: DHW tank

E K HT 200

E: European model

HT: high temperature tank

S: Stainless steel tank

Water volume:

200: 200 L tank

260: 260 L tank

S

K: indoor model

(U)

DHW tank type:

No letter: standard tank

U: UK tank

P: passivated + service opening

A

A: model change

Page 49: Internal use only Daikin Altherma HT. 2 10-Oct-14 Internal use only Name: J. Logghe Dept: New Business Table of contents 1. Product concept 2. Product.

49Apr 11, 2023

Internal use only

Name: J. Logghe • Dept: New Business

Table of contents

1. Product concept

2. Product features

4. Product line-up

4. Nomenclature

5. Specifications

6. Summary

3. Applications

Page 50: Internal use only Daikin Altherma HT. 2 10-Oct-14 Internal use only Name: J. Logghe Dept: New Business Table of contents 1. Product concept 2. Product.

50Apr 11, 2023

Internal use only

Name: J. Logghe • Dept: New Business

Specifications: Sound Data

Outdoor unit Sound Pressure at 1m 52 dBA 53 dBA 55 dBA

011 model 014 model 016 model

Sound Power 68 dBA 69 dBA 71 dBA

Position for measuring the Sound Pressure level of the outdoor unit

Page 51: Internal use only Daikin Altherma HT. 2 10-Oct-14 Internal use only Name: J. Logghe Dept: New Business Table of contents 1. Product concept 2. Product.

51Apr 11, 2023

Internal use only

Name: J. Logghe • Dept: New Business

Specifications: Sound Data

Indoor unit: Sound Pressure level

Sound Pressure level in front of the indoor unit

Maximum Sound Pressure level possible at the four other microphones

Two different ways of measuring the Sound Pressure level of the indoor unit

Page 52: Internal use only Daikin Altherma HT. 2 10-Oct-14 Internal use only Name: J. Logghe Dept: New Business Table of contents 1. Product concept 2. Product.

52Apr 11, 2023

Internal use only

Name: J. Logghe • Dept: New Business

Specifications: Sound Data

Indoor unit: Sound Pressure level

Low sound mode has three different steps, Sound Pressure level of mode n°2 and n°3 is lower than n°1

Page 53: Internal use only Daikin Altherma HT. 2 10-Oct-14 Internal use only Name: J. Logghe Dept: New Business Table of contents 1. Product concept 2. Product.

53Apr 11, 2023

Internal use only

Name: J. Logghe • Dept: New Business

Specifications: Sound Data

Indoor unit

011 model 014 model 016 model

Sound Power 59 dBA 60 dBA 60 dBA

Measurement condition:

• Ta=7/6°C

• Heating setpoint 70/80°C

• Maximum compressor frequency

Page 54: Internal use only Daikin Altherma HT. 2 10-Oct-14 Internal use only Name: J. Logghe Dept: New Business Table of contents 1. Product concept 2. Product.

54Apr 11, 2023

Internal use only

Name: J. Logghe • Dept: New Business

Specifications: Operation range space heating

Space heating

Shift value of 5°C is possible via field setting

Page 55: Internal use only Daikin Altherma HT. 2 10-Oct-14 Internal use only Name: J. Logghe Dept: New Business Table of contents 1. Product concept 2. Product.

55Apr 11, 2023

Internal use only

Name: J. Logghe • Dept: New Business

Specifications: Operation range DHW heating

DHW heating

Page 56: Internal use only Daikin Altherma HT. 2 10-Oct-14 Internal use only Name: J. Logghe Dept: New Business Table of contents 1. Product concept 2. Product.

56Apr 11, 2023

Internal use only

Name: J. Logghe • Dept: New Business

Specifications: Capacity table

Conditions for Capacity table

Page 57: Internal use only Daikin Altherma HT. 2 10-Oct-14 Internal use only Name: J. Logghe Dept: New Business Table of contents 1. Product concept 2. Product.

57Apr 11, 2023

Internal use only

Name: J. Logghe • Dept: New Business

Specifications: Capacity table (nominal values)

Page 58: Internal use only Daikin Altherma HT. 2 10-Oct-14 Internal use only Name: J. Logghe Dept: New Business Table of contents 1. Product concept 2. Product.

58Apr 11, 2023

Internal use only

Name: J. Logghe • Dept: New Business

Specifications: Capacity table (peak values)

Page 59: Internal use only Daikin Altherma HT. 2 10-Oct-14 Internal use only Name: J. Logghe Dept: New Business Table of contents 1. Product concept 2. Product.

59Apr 11, 2023

Internal use only

Name: J. Logghe • Dept: New Business

Specifications: Capacity table (peak values)

HC = f(Ta), TLW = 65°C

0,00

2,00

4,00

6,00

8,00

10,00

12,00

14,00

16,00

18,00

-20 -15 -10 -5 0 5 10 15

Ta (°C)

HC

(kW

)

EKHBRD 011 EKHBRD 014 EKHBRD 016

Page 60: Internal use only Daikin Altherma HT. 2 10-Oct-14 Internal use only Name: J. Logghe Dept: New Business Table of contents 1. Product concept 2. Product.

60Apr 11, 2023

Internal use only

Name: J. Logghe • Dept: New Business

Specifications: Capacity table (peak values)

COP = f(Ta), TLW = 65°C

0,00

0,50

1,00

1,50

2,00

2,50

3,00

3,50

4,00

-20 -15 -10 -5 0 5 10 15

Ta (°C)

CO

P

EKHBRD 011 EKHBRD 014 EKHBRD 016

Page 61: Internal use only Daikin Altherma HT. 2 10-Oct-14 Internal use only Name: J. Logghe Dept: New Business Table of contents 1. Product concept 2. Product.

61Apr 11, 2023

Internal use only

Name: J. Logghe • Dept: New Business

Specifications: Capacity table (peak values)

HC = f(Ta,TLW), EKHBRD 014

0,00

2,00

4,00

6,00

8,00

10,00

12,00

14,00

16,00

-20 -15 -10 -5 0 5 10 15

Ta (°C)

HC

(kW

)

TLW = 45°C TLW = 55°C TLW = 65°C TLW = 75°C TLW = 80°C

Page 62: Internal use only Daikin Altherma HT. 2 10-Oct-14 Internal use only Name: J. Logghe Dept: New Business Table of contents 1. Product concept 2. Product.

62Apr 11, 2023

Internal use only

Name: J. Logghe • Dept: New Business

Specifications: Capacity table (peak values)

COP = f(Ta,TLW), EKHBRD 014

0,00

0,50

1,00

1,50

2,00

2,50

3,00

3,50

4,00

4,50

-20 -15 -10 -5 0 5 10 15

Ta (°C)

CO

P

TLW = 45°C TLW = 55°C TLW = 65°C TLW = 75°C TLW = 80°C

Page 63: Internal use only Daikin Altherma HT. 2 10-Oct-14 Internal use only Name: J. Logghe Dept: New Business Table of contents 1. Product concept 2. Product.

63Apr 11, 2023

Internal use only

Name: J. Logghe • Dept: New Business

Specifications: Capacity table (integrated values)

Page 64: Internal use only Daikin Altherma HT. 2 10-Oct-14 Internal use only Name: J. Logghe Dept: New Business Table of contents 1. Product concept 2. Product.

64Apr 11, 2023

Internal use only

Name: J. Logghe • Dept: New Business

Specifications: Capacity table (integrated values)

HC = f(Ta), TLW = 65°C

0,00

2,00

4,00

6,00

8,00

10,00

12,00

14,00

16,00

18,00

-20 -15 -10 -5 0 5 10 15

Ta (°C)

HC

(kW

)

EKHBRD 011 EKHBRD 014 EKHBRD 016

Page 65: Internal use only Daikin Altherma HT. 2 10-Oct-14 Internal use only Name: J. Logghe Dept: New Business Table of contents 1. Product concept 2. Product.

65Apr 11, 2023

Internal use only

Name: J. Logghe • Dept: New Business

Specifications: Capacity table (integrated values)

COP = f(Ta,TLW), EKHBRD 014

0,00

0,50

1,00

1,50

2,00

2,50

3,00

3,50

4,00

4,50

-20 -15 -10 -5 0 5 10 15

Ta (°C)

CO

P

TLW = 45°C TLW = 55°C TLW = 65°C TLW = 75°C TLW = 80°C

Page 66: Internal use only Daikin Altherma HT. 2 10-Oct-14 Internal use only Name: J. Logghe Dept: New Business Table of contents 1. Product concept 2. Product.

66Apr 11, 2023

Internal use only

Name: J. Logghe • Dept: New Business

Specifications: COP Peak values LT and HT

COP values for 16kW model (3 phase) at Ta = 7°C):

Daikin Altherma LT Split and Daikin Altherma HT

Daikin Altherma HT = excellent heat pump for High Temperature applications

Daikin Altherma LT = excellent heat pump for Low Temperature applications

Page 67: Internal use only Daikin Altherma HT. 2 10-Oct-14 Internal use only Name: J. Logghe Dept: New Business Table of contents 1. Product concept 2. Product.

67Apr 11, 2023

Internal use only

Name: J. Logghe • Dept: New Business

Specifications: Dimensions

Indoor unit: hydrobox + DHW tank Outdoor unit

695

mm

600 mm

2010 mm

2285 mm

705 mm

70 kg

V1: 144kg

Y1: 147kg

78 kg

900 mm320 m

m

120 kg1345 mm

V1: 144kg

Y1: 147kg

Page 68: Internal use only Daikin Altherma HT. 2 10-Oct-14 Internal use only Name: J. Logghe Dept: New Business Table of contents 1. Product concept 2. Product.

68Apr 11, 2023

Internal use only

Name: J. Logghe • Dept: New Business

Specifications: Packing and shipping

Front-packing of DHW tank Back-packing of DHW tank Back-packing of Hydrobox

4 EPS corners Top is made of carton The whole unit is foiled Unit is fixed on palette

Page 69: Internal use only Daikin Altherma HT. 2 10-Oct-14 Internal use only Name: J. Logghe Dept: New Business Table of contents 1. Product concept 2. Product.

69Apr 11, 2023

Internal use only

Name: J. Logghe • Dept: New Business

Table of contents

1. Product concept

2. Product features

4. Product line-up

4. Nomenclature

5. Specifications

6. Summary

3. Applications

Page 70: Internal use only Daikin Altherma HT. 2 10-Oct-14 Internal use only Name: J. Logghe Dept: New Business Table of contents 1. Product concept 2. Product.

70Apr 11, 2023

Internal use only

Name: J. Logghe • Dept: New Business

To summarize: product features

Tlwc up to 80°C => refurbishment market, no booster heater

Full H/P tariff

Unit operates with guaranteed capacity down to - 20°C

Newly designed casing in modern metallic color

Integrated design of hydrobox and DHW tank

All required hydraulic parts are included in hydrobox

DC inverter pump to maintain fixed ΔT

User interface can be used as a room thermostat

Flat Peak capacity trend down to -7°C for Tlwc = 80°C

Standard bottom plate heater on ERRQ, controlled by indoor unit