INTERNAL & EXTERNAL QUALITY CONTROL Leo Spaapen and Brian Fowler
19

INTERNAL & EXTERNAL QUALITY CONTROL€¦ · INTERNAL & EXTERNAL QC GUIDELINE: • Firstly, control the analytical / methodological performance with well defined pooled urine and/or

Jul 03, 2020

Download

Documents

dariahiddleston
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: INTERNAL & EXTERNAL QUALITY CONTROL€¦ · INTERNAL & EXTERNAL QC GUIDELINE: • Firstly, control the analytical / methodological performance with well defined pooled urine and/or

INTERNAL & EXTERNALQUALITY CONTROL

Leo Spaapen and Brian Fowler

Page 2: INTERNAL & EXTERNAL QUALITY CONTROL€¦ · INTERNAL & EXTERNAL QC GUIDELINE: • Firstly, control the analytical / methodological performance with well defined pooled urine and/or

Why should we control the quality of our analytical data?

Page 3: INTERNAL & EXTERNAL QUALITY CONTROL€¦ · INTERNAL & EXTERNAL QC GUIDELINE: • Firstly, control the analytical / methodological performance with well defined pooled urine and/or

Although we use ingenious sophisticated analytical methods they can provide erroneous and therefore misleading data.

Medical action based on false data is more dangerous than medical action without certain data.

NO NUMBER IS SAFER THAN A FALSE NUMBER!!

Page 4: INTERNAL & EXTERNAL QUALITY CONTROL€¦ · INTERNAL & EXTERNAL QC GUIDELINE: • Firstly, control the analytical / methodological performance with well defined pooled urine and/or

Validation of Analytical Methodsfor every metabolite to be quantified

• Specificity• Selectivity • Accuracy • Trueness (Bias)

– Bias (total systematic error)• Precision (repeatability and reproducibility)• Linearity

Page 5: INTERNAL & EXTERNAL QUALITY CONTROL€¦ · INTERNAL & EXTERNAL QC GUIDELINE: • Firstly, control the analytical / methodological performance with well defined pooled urine and/or

Validation of Analytical Methodsfor every metabolite to be quantified

• Calibration• Range incl. detection limit• Matrix variation effect• Recovery • Robustness• Sensitivity

Page 6: INTERNAL & EXTERNAL QUALITY CONTROL€¦ · INTERNAL & EXTERNAL QC GUIDELINE: • Firstly, control the analytical / methodological performance with well defined pooled urine and/or

ACCURACY

(fair accuracy) (poor accuracy)

(high accuracy) (fair accuracy)

Page 7: INTERNAL & EXTERNAL QUALITY CONTROL€¦ · INTERNAL & EXTERNAL QC GUIDELINE: • Firstly, control the analytical / methodological performance with well defined pooled urine and/or

Please put your hand up if you perform internalquality control by using a pooled urine/plasma:

• at amino acid analysis• at GC-MS analysis of organic acids

Page 8: INTERNAL & EXTERNAL QUALITY CONTROL€¦ · INTERNAL & EXTERNAL QC GUIDELINE: • Firstly, control the analytical / methodological performance with well defined pooled urine and/or

6% 10%

35%

49%

Yes (pooled urine/plasma) Yes (but without details)? (no information) No

12%

22%

26%

40%

PERFORMANCE OF INTERNAL QUALITY CONTROL

questionnaire 1995

QC Organic acids (n = 76) QC Amino acids (n = 121)

Page 9: INTERNAL & EXTERNAL QUALITY CONTROL€¦ · INTERNAL & EXTERNAL QC GUIDELINE: • Firstly, control the analytical / methodological performance with well defined pooled urine and/or

INTERNAL QUALITY CONTROL

AIM: to limit the analytical variation by controlling the day to day performance of the analyses in your laboratory;

- Precision (repeatability and reproducibility)- Trueness (Bias)- Linearity

Page 10: INTERNAL & EXTERNAL QUALITY CONTROL€¦ · INTERNAL & EXTERNAL QC GUIDELINE: • Firstly, control the analytical / methodological performance with well defined pooled urine and/or

INTERNAL QUALITY CONTROLMaterial to be used (matrix must be similar to samples for the daily analyses):

pooled plasmas and/or urines possibly spiked with metabolites; * home made

* commercial available

Page 11: INTERNAL & EXTERNAL QUALITY CONTROL€¦ · INTERNAL & EXTERNAL QC GUIDELINE: • Firstly, control the analytical / methodological performance with well defined pooled urine and/or

INTERNAL QUALITY CONTROLFrequency of internal quality controlsguidelines:- Batch processing: analyze a pool sample each run

- Continuous processing: analyze a pool sample each 24 hours

- Analyze a pool sample after:- change of chromatographic parameters- refreshment of buffers- refreshment of derivatization agent (e.g. ninhydrin)

Page 12: INTERNAL & EXTERNAL QUALITY CONTROL€¦ · INTERNAL & EXTERNAL QC GUIDELINE: • Firstly, control the analytical / methodological performance with well defined pooled urine and/or

EXTERNAL QUALITY CONTROL

AIM: 1. To optimize inter-laboratory comparability

2. To approach the accuracy of analytical data (data from many laboratories needed)

3. To check your internal quality controls

4. To improve diagnostic skill by Proficiency testing

Page 13: INTERNAL & EXTERNAL QUALITY CONTROL€¦ · INTERNAL & EXTERNAL QC GUIDELINE: • Firstly, control the analytical / methodological performance with well defined pooled urine and/or

INTERNAL & EXTERNAL QC GUIDELINE:

• Firstly, control the analytical / methodological performance with well defined pooled urine and/or plasma samples.

• Secondly, use the data from the ERNDIM QAP to check your internal quality controls.

• Don’t use the external control samples for your internal quality control.

IMPORTANT: evaluation and aftercare

Page 14: INTERNAL & EXTERNAL QUALITY CONTROL€¦ · INTERNAL & EXTERNAL QC GUIDELINE: • Firstly, control the analytical / methodological performance with well defined pooled urine and/or

improvement of between Labs CV

0,05,0

10,015,020,025,030,035,040,0

1995 2000 2002 2004

Homocysteine Phenylalanine

Page 15: INTERNAL & EXTERNAL QUALITY CONTROL€¦ · INTERNAL & EXTERNAL QC GUIDELINE: • Firstly, control the analytical / methodological performance with well defined pooled urine and/or

Amino acid QC scheme: Precision vs. Amino acid QC scheme: Precision vs. InterlabInterlab variationvariation

02468

101214161820222426

0 2 4 6 8 10 12 14 16

Ala

αAB

Arg

ASA

AspN

AspA

Cit

Cysta

GluN

Cys

GluAGly

His

1MeHisOH-LysSarc

Lys

ProLeu

Phe

Met

OH-Pro

Orn

Tau

Ser

TyrThr

ILeu

Val

>

> %

%

Precision, within lab CV

Between labs CV

Page 16: INTERNAL & EXTERNAL QUALITY CONTROL€¦ · INTERNAL & EXTERNAL QC GUIDELINE: • Firstly, control the analytical / methodological performance with well defined pooled urine and/or
Page 17: INTERNAL & EXTERNAL QUALITY CONTROL€¦ · INTERNAL & EXTERNAL QC GUIDELINE: • Firstly, control the analytical / methodological performance with well defined pooled urine and/or

Mean all labs 114 µµmol/Lmol/L

Page 18: INTERNAL & EXTERNAL QUALITY CONTROL€¦ · INTERNAL & EXTERNAL QC GUIDELINE: • Firstly, control the analytical / methodological performance with well defined pooled urine and/or

Mean all labs 12.9 µµmol/Lmol/L

Page 19: INTERNAL & EXTERNAL QUALITY CONTROL€¦ · INTERNAL & EXTERNAL QC GUIDELINE: • Firstly, control the analytical / methodological performance with well defined pooled urine and/or

THANKS ARE DUE TO:

ILJA LARDINOIS & HUGUETTE VRANCKEN