    s

    IntroductionFor manufacturers flexible and eco-nomic production is the only way of en-suring that products meet the rapidlychanging needs of the customer.

    Distributed automation structures areone of the factors needed for flexibleand economic production. Therequired flow of information is ensuredby interconnecting the various areas ofthe system over local area networks.

    In the field of industrial communica-tions, networks complying with nationaland international standards enable the

    exchange of information at all levels ofthe automation hierarchy.

    PROFIBUS-DP fieldbus

    The PROFIBUS-DP fieldbus has be-come established at the field level,where a high-speed response is re-quired and small amounts of data aregenerally exchanged.

    PROFIBUS-DP is an open fieldbus sys-tem and is standardized to Europeanand international standards. This field-bus system is also the basis forPROFIBUS-PA, the fieldbus for processautomation.

    Features

    The PROFIBUS-DP fieldbus is charac-terized by the following features:

    Corresponds to the European stan-dard EN 50 170, Volume 2

    Corresponds to IEC 61158-3, Ed. 2 Comprehensive range of fieldbus

    components

    Data transmission via two-wire or fi-ber optic system

    SIMATICPROFIBUS Interface Components

    All designations in this product brief marked with are registered trademarks of Siemens AG. Theother designations in this product brief might betrademarks, the use of which by third parties couldinfringe the rights of the respective owners.

    Flexible and modular design of theautomation system possible

    Connection to actuator-sensor inter-face possible

    Reduction in wiring overhead Up to 125 nodes can be connected

    with up to 32 per bus segment

    Short response times thanks to trans-mission rates of up to 12 Mbit/s

    Coverage of distances up to 23.8 km/14.7 miles

    Simple connection of devicesthrough the availability of ASICsand interface modules

    PROFIBUS-DP is the system bus forTotally Integrated Automation Leading PLC vendors recognize

    PROFIBUS-DP as a standard inter-face for the field level.

    ASICs and interface modules

    The interface to the PROFIBUS-DPfieldbus is open.

    The ASICs and interface modulesdescribed below provide third-partyvendors with a simple and cost effec-tive interface design for connectingtheir devices and systems toPROFIBUS-DP.

    Various ASICs and interface modulesare available for different functionalneeds (master function, both simpleand intelligent slave stations).

    ASICs and interface modules aredescribed on the following pages.

  • 7/28/2019 Interfacecomponent Siemens

    2/16

    2 2

    Application

    PROFIBUS is the network for the fieldand cell areas.

    Three principle types are availabledepending on requirements:

    PROFIBUS-DP PROFIBUS-FMS PROFIBUS-PA.

    PROFIBUS-DP

    The PROFIBUS-DP fieldbus featureshigh-speed communication with smallamounts of data and high system avail-ability.

    It corresponds to the EN 50 170 stan-dard, Volume 2 with the DP protocolvariant. In addition, PROFIBUS-DP isthe basis for PROFIBUS-PA.

    PROFIBUS-FMS

    PROFIBUS-FMS is designed for com-plex communications tasks at the celllevel.

    It corresponds to the EN 50 170 stan-dard, Volume 2, with the FMS protocolvariant.

    PROFIBUS-PA

    PROFIBUS-PA is the PROFIBUS ver-

    sion for process automation.PROFIBUS-PA complies with the EN50170 standard, Amendment 2.

    PROFIBUS-PA uses transmission tech-nology in accordance with IEC 1158-2.This transmission process can also beused for intrinsically safe applications.The communication protocols ofPROFIBUS-PA and PROFIBUS-DP areidentical. PROFIBUS-DP communica-tion protocol + IEC-1158-2 transmis-sion technology = PROFIBUS-PA.

    Design

    PROFIBUS-DP is different for activebus participants and passive bus par-ticipants.

    Active nodes (masters)

    Programmable controllers, e.g.S7-300/S7-400;M7-300/M7-400

    PC-based Control Systems, e.g.WinAC

    SIMATIC programming devicesand PCs

    HMI devices Machine controllers, e.g.

    SINUMERIK

    Control systems, e.g. SIMADYN

    Third-party PLCs

    Passive nodes (slaves)

    Distributed I/O stationsSIMATIC ET 200;

    Controllers, e.g. S7-200/S7-300and S5-95U/DP;

    Field devices such as drives or hu-man-machine interface units;

    Field devices of process technology,e.g. SITRANS

    Third-party field devices

    The PROFIBUS-DP fieldbus can be in-stalled in two-wire cable, fiber optic orhybrid configurations

    Mode of operation

    he nodes in the network share thetransmission medium. A system istherefore required to control access to

    the network.PROFIBUS-DP operates according tothe master/slave token passing ac-cess method, whereby only activenodes receive the right access the net-work. The right to access is transferredby passing a token from one master tothe next. If there is no request to send,the token is passed on to the next mas-ter.

    The passive bus nodes are polled di-rectly by the master module assignedto them.

    Open interfaces for PROFIBUS-DP/

    PROFIBUS-PAThe communication performancerequired for the short response timescannot be achieved using the usual

    standard components.

    Siemens has therefore developed sev-eral high-performance ASICs for inter-facing the PROFIBUS-DP.

    These ASICs handle a significant pro-

    portion of the communication. The in-terface modules supplied for masterand slave applications are based onthese ASICs.

    Integration centers

    The integration centers support fielddevice vendors by providing adviceprior to and during development, aswell as performing the required integra-tion tests.

    They also provide additional informa-tion on ASICs, interfaces and develop-ment kits.

    The addresses of the Integration Cen-ters are shown in page 9.

    PROFIBUS User Organization

    The PROFIBUS User Organization(PNO), which represents users andmanufacturers of PROFIBUS products,provides a platform for co-operationand exchange of information.

    PROFIBUS User Organization (PNO)Haid-und-Neu-Strae 7D-76131 KarlsruheGermanyFax: 0721/96 58 589www.profibus.com

    PROFIBUS-DP, PROFIBUS-PA Fieldbus

    Fig. 1 Typical configuration of a PROFIBUS-DP/PA fieldbus

    S7-300/S7-400programmablecontroller

    SIMATIC S5/TIprogrammable controller

    Master devices

    Slave devices

    ET 200M

    Programming device

    ET 200XET 200L

    Human-machine

    interface

    SITRANS P

    DP/PA link

  • 7/28/2019 Interfacecomponent Siemens

    3/16

    3 3

    Application

    The PROFIBUS ASICs facilitate theconnection of third-party componentsand systems to the PROFIBUS field-bus.

    Quick reaction times for thePROFIBUS-DP, which are required fortransmission rates of up to 12 Mbit/s,can only be achieved by using theseASICs.

    Various ASICs are available for differ-ent functional needs and applications.

    Master-ASICs

    The ASPC 2 (Advanced Siemens

    PROFIBUS Controller) is an intelligentcommunications chip for master appli-cations. This ASIC is suitable for use inmaster interface modules for connec-tion to PROFIBUS-DP and PROFIBUS-FMS. The maximum transmission rateis 12 Mbit/s for PROFIBUS-DP.

    Intelligent Slave-ASICs

    The SPC 3 (Siemens PROFIBUS Control-ler) is an intelligent communications chipfor slave applications. It enables con-nection to PROFIBUS-DP. The maximumtransmission rate is 12 Mbit/s.

    Slave ASIC with processor coreThe DPC 31 combines the functionsof the SPC 3, SPC 41 and an 8031processor in a single chip. The DPC 31makes available a DP slave controllerwhich is highly flexible and can there-fore be used in an enormous variety ofapplications.

    The DPC 31 is particularly suitable foruse in intrinsically safe applicationsbecause of its low-power system. Itenables connection to PROFIBUS-DP,PROFIBUS-FMS and PROFIBUS-PA.

    With the SIM 1 the DPC 31 offers an

    integrated compact solution for con-necting a PROFIBUS-PA using a trans-mission procedure according to IEC1158-2.

    The maximum transmission rate is12 Mbit/s for PROFIBUS-DP and31.25 kbit/s for PROFIBUS-PA.

    Simple Slave-ASICs

    The SPM 2 (Siemens PROFIBUS Multi-plexer) is a single-chip solution for sim-ple slave applications. The maximumtransmission rate is 12 Mbit/s.

    The LSPM 2 is, like the SPM 2, a single-chip solution for simple slave applica-tions, but its compact package makesit particularly suitable for applicationswhere space is at a premium. The max-imum transmission rate is 12 Mbit/s.

    Operation

    The ASICs handle a large part of the

    communications tasks between thebus node and the network.

    The ASICs of the SPM range (SPM 2and LSPM 2) handle all communica-tions tasks completely independently.The correct signals only need to beapplied to the pins. An additional pro-cessor or firmware is not required.

    The ASICs of the SPC range (SPC 3,SPC 41, DPC 31 and ASPC 2) areequipped with a processor interface.They require additional firmware for theinterface between the ASIC and the ap-plication.

    FirmwareThe firmware is installed in a processoron the interface module or in the fielddevice. The functions of the fielddevice are included via the call inter-face.

    The scope of the firmware depends onthe ASIC.

    Delivery arrangements

    The ASICs can be obtained through theworldwide distribution network ofSiemens AG. Quantities of 5 ASICs orover can be ordered for testing.

    For series production, only multiples ofan ASIC packaging unit (tray) are pos-sible. The number of ASICs per pack-age depends on the type of ASIC.

    Please refer to the technical specifica-tions on page 16 for more details onpackaging units.

    Documentation

    Descriptions of the interface compo-nents are available on the Internet. TheInternet address is:

    http://www.ad.siemens.de/csi_e/dpLook under:

    Distributed I/OOthersDevelopment componentsManuals

    Fig. 2 Classification of ASICs according to application and version

    Overview of PROFIBUS-ASICs

    Masterapplications

    ASPC 2

    Intelligentslaveapplications

    Simpleslaveapplications

    LSPM 2SPM 2

    SPC3

    SPC41

    DPC31

    SIM1

    RS 485

    IEC 1158-2

    12 Mbit/s

  • 7/28/2019 Interfacecomponent Siemens

    4/16

    4 4

    Application

    The ASICs SPM 2 (Siemens PROFIBUSMultiplexer) and LSPM 2 (LeanSiemens PROFIBUS Multiplexer) aresingle-chip solutions for simple slaveapplications. Examples include sen-sors and actuators such as switches,indicators and thermocouples. TheASICs enable connection to thePROFIBUS-DP fieldbus.

    The smaller package makes theLSPM 2 particularly suitable for use inapplications where space is at a pre-mium.

    The maximum transmission rate is12 Mbit/s.

    The IM 184 interface module is imple-mented with the ASIC LSPM 2.

    Design

    The SPM 2 has 64 input/output bits. It isaccommodated in a PQFP packagewith 120 pins.

    The subdivision of the input/outputpoints into inputs and outputs is config-urable. Pins are also provided on theASICs for diagnostic information.

    The SPM 2 handles the complete datatraffic independently. An additionalmicroprocessor and firmware are notrequired.

    It is thus possible, using a small num-ber of external components, to imple-ment a simple connection to thePROFIBUS-DP fieldbus.

    The LSPM 2 has the same functionalityas the SPM 2, except that it only has 32input/ output bits. It is accommodatedin a compact MQFP package with 80pins.

    Operation

    The SPM 2 and the LSPM 2 handle thebus protocol fully independently. Thepins only need to be connected to theinput /output signals and bus cables.

    The SPM 2 and the LSPM 2 operate asslaves on the PROFIBUS-DP network.When they receive an error-free mes-sage frame from the master, they gen-erate the requested reply framesindependently.

    Features

    PROFIBUS-DP protocol Maximum transmission rate 12 Mbit/s Automatic detection of transmission

    rate

    RS 485 transmission protocol PQFP package with 120 pins for SPM 2

    andMQFP package with 80 pins forLSPM 2

    Integrated ASIC circuit (glue logic) 64 input/output bits for SPM 2,

    of which up to 32 diagnostics inputs;32 input/output bits for LSPM 2,of which up to 16 diagnostics inputs

    8 separate diagnostics inputs User-specific allocation of input/out-

    put points to inputs and outputs

    Integrated watchdog timer External quartz port for 24 MHz and

    48 MHz quartz/oscillator

    5 V DC power supply.

    Firmware

    No firmware is required for operation ofthe SPM 2 and the LSPM 2.

    The entire protocol handling is per-formed by the ASICs.

    ASICs SPM 2 und LSPM 2

    Fig. 3 Integration of the LSPM 2 ASIC in a slave interface module

    PROF

    IBUS-D

    Pfieldbus

    Quartz

    Connectorstripforhostnetwork

    Reset

    RS

    485driver

    with

    galvanicisolation

    Jumper Diagnostics EPROMsocket

    LSPM 2 Port A

    Port B

    Port D

    Port C

    Port E

  • 7/28/2019 Interfacecomponent Siemens

    5/16

    5 5

    Application

    The SPC 3 is an intelligent communica-tions chip for slave applications. It en-ables connection to the PROFIBUS-DPfieldbus.

    The IM 183-1 interface module is imple-mented with the SPC 3.

    The maximum transmission rate is12 Mbit/s.

    Design

    The SPC 3 has a 1.5 Kbyte messageframe memory.

    It is accommodated in a PQFP pack-age with 44 pins.

    Operation

    The SPC 3 handles all communicationstasks of the PROFIBUS-DP protocolcompletely independently.

    This accelerates protocol handling andreduces the scope of the software inthe microprocessor of the interfacemodule.

    Bus access is hardware driven. Datatransfer takes place via a 1.5 KbyteRAM. The interface to the application isa data interface. Therefore, the datacan be transferred independent of thebus cycle.

    Firmware with call interfaces for theapplication is provided for convenientoperation with the microprocessor.

    Features

    PROFIBUS-DP/-DPV1 protocol Maximum transmission rate 12 Mbit/s Automatic detection of transmission

    rate

    Support of microprocessors 80C32,80X86, 80C166, 80C165, 80C167and HC11, HC16 and HC916 types

    RS 485 transmission PQFP package with 44 pins Independent handling of communi-

    cations functions including thePROFIBUS-DP protocol

    Integrated watchdog timer

    External quartz port for 48 MHzquartz 5 V DC power supply.

    Firmware

    Firmware (in C source code) is sup-plied as an interface between the reg-isters of the SPC 3 and the application.

    The firmware is operated on the pro-cessor of the field device and providescall interfaces for simple integration ofthe application.

    The firmware consists of approximately4 to 24 Kilobytes and can also be usedforIM 182-1 and IM 183-1 interface mod-ules.

    The firmware is not absolutely neces-sary for the operation of the SPC 3 withthe DP standard functions, since theASICs registers are fully documented;however, the firmware enables the userto save time which he would otherwisebe required to spend for developmentwork.

    The firmware is required for the use ofthe additional DP functions DPV1(read/write data set).

    Fig. 4 Integration of the SPC 3 ASIC in a slave application

    ASIC SPC 3

    PROF

    IBUS-D

    Pfieldbus

    Quartz48 MHz

    RS

    485driver

    with

    galvanicisolation

    SPC 3 Micro-processor

    Data andaddress

    INT

    WR/RD

    Reset

    Reset

  • 7/28/2019 Interfacecomponent Siemens

    6/16

    6 6

    Application

    DPC31 combines the different featuresof the ASICs SPC3 and SPC4 in onechip, which means that this chip is suit-able for a wide range of applications.The DPC31 is an intelligent communi-cations chip with an integrated proces-sor core. It allows intelligent fielddevices to be connected to thePROFIBUS-DP. Because of the powermanagement system and the 3.3 Vtechnology, the DPC31 can also beused in process technology in connec-tion with the PROFIBUS-PA.

    The DPC31 allows a slave applicationto be realized with minimal expenditureon external components.

    Design

    In order to be connected to the physi-cal bus, the DPC31 not only has anasynchronous interface for the RS485interface, but also has a synchronousinterface to the SIM1. This interfaceallows the DPC31 to be connected tothe synchronous transmission technol-ogy of the IEC 1158-2 structure, whichuses PROFIBUS-PA, via an energy-saving interface.

    The DPC31 has 6 Kilobytes of RAM,which serves as message frame mem-ory, and an integrated 8031 core.24 Kilobytes of firmware ROM hasbeen integrated for the 8031 core.

    The DPC31 is accommodated in aPQFP housing with 100 pins.

    Operation

    The DPC31 handles the entire DP slaveprotocol independently and relievesthe application from all time-criticalcommunication functions. All the nec-essary timer and monitoring functions

    are integrated in the DPC31.The interface to the application is madeup of 6 Kilobytes of RAM, throughwhich the application communicateswith the communication part of theDPC31. The interface takes the form ofa data interface. Firmware with a callinterface is also provided to facilitateoperation with an external processor.

    The integrated 8031 core is 100 %compatible to standard 8031 deriva-tives. This means that all standarddeveloping environments can be usedfor programming and debugging.

    256 bytes of internal RAM and thetimer 2 of the 8032 derivatives are

    added to the integrated 8031 core,meaning that a genuine 8032 controlleris available in the DPC31.

    The firmware ROM for the 8031 corehas the following functions:

    Read and write functions for SPIcompatible E2PROM

    Boot loader for single-chip applica-tions

    All system functions necessary forthe realization of a DP slave.

    The DPC31 offers the following opera-tion options:

    DPC31 as single-chip applications DPC31 with external ROM/RAM DPC31 with external microprocessor

    Features

    PROFIBUS-DP/-DPV1 protocol(read / write data set)

    Maximum transmission rate12 Mbit/s, using transmission methodIEC 1158-2 31.25 kbit/s

    Automatic detection of transmissionrate

    Asynchronous Interface according toPROFIBUS-DP

    Synchronous interface according toPROFIBUS-PA

    Integrated 8031 core SSC interface to connect SPI com-

    patible components, such asE2PROMs or AD converters

    Standard 8031 interface External Intel and Motorola micropro-

    cessor interface

    Supply voltage 3.3 V DC PQFP housing with 100 pins

    Firmware

    There is firmware (C Code) for theDPC31 which makes using the compo-

    nent even simpler. The firmware is runon the processor of the field device andoffers a simple function interface forsimple linking of the application.

    Fig. 5 Block diagram of the DPC31

    DPC 31 Communications Chip

    Bus and boot typesetting, reset

    27 pin I/O port orexternal uP interface

    4 ports +special functionsSPI interface

    multifunctionalI/O interface

    SSCModule

    8031 I/O interface(emulator port)

    ROM(24Kbyte)

    Register cells

    6 Kbytecommunicationand code RAM

    Micro-sequencer

    Multi-port-RAMcontroller

    Standard 8031 corewith 256 bytes RAMand additional

    timer 2

    Phys. unit

    async. sync.PLL +clock unit

    PROFIBUSinterface

    Clkout 1/2Clkout 1/4

    12 MHz quartz ordirect supply

    Test andsupply pins

  • 7/28/2019 Interfacecomponent Siemens

    7/16

    7 7

    Application

    The SIM 1 (Siemens IEC MediumAttachment Unit) matches the signalsfor the connection of field devices toIEC 1158-2 and thus also toPROFIBUS-PA.

    PROFIBUS-PA is the PROFIBUS ver-sion for process automation.

    The transmission process matches IEC1158-2, the communication protocol isPROFIBUS-DP.

    PROFIBUS-PA can also be used for in-trinsically safe applications.

    Design

    The SIM 1 is an expansion of the DPC31. Only a few external componentsare required in addition to this ASIC, inorder to connect PROFIBUS-PA fielddevices to an intrinsically safe network.

    The SIM 1 is accommodated in a TQFPhousing with 44 pins.

    Operation

    The SIM 1 supports all send andreceive functions as well as the high-resistance tapping of the auxiliarypower from the bus cable. It provides 2

    stabilized power supplies and enablesthe installation of a galvanically isolatedpower supply. It can be connected toall IEC 1158-2 compliant Manchesterencoders/decoders.

    Features

    IEC 1158-2 compliant and thusPROFIBUS-PA compliant transmis-sion method

    Transmission rate is 31.25 kbit/s

    TQFP housing with 44 pins

    Extraction of auxiliary power of 3.3 VDC and 5 V DC or 5 V DC and 6.6 VDC (power loss up to 250 mW)

    Power consumption from the fieldbusto supply the unit can be set to up to

    40 mA.

    SIM 1 Interface Chip

    Fig. 7 Integration of the DPC 31 and SIM 1 ASICs in a slave application

    Fig. 6 Use of the PROFIBUS-PA fieldbus in process automation

    DPC 31 Microprocessor(optional)

    SIM 1

    TxS

    RxS

    DC 3.3 V

    DC 5 V

    INT

    WR/RD

    Reset

    Reset

    PROFIBUS-P

    Afieldbus

    Data andaddress

    Quartz Quartz

    Bu

    svoltage9V

    ...

    32V

  • 7/28/2019 Interfacecomponent Siemens

    8/16

    8 8

    Application

    The ASPC 2 is an intelligent communi-cations chip for master applications. Itenables connection to PROFIBUS-DPand PROFIBUS-FMS.

    It is also possible to connect to thePROFIBUS-PA via the DP/PA link.

    These ASICs are used to off-load com-munications handling tasks from pro-grammable controllers, personal com-puters, drive controls and human-machine interfaces.

    The IM 180 interface module is imple-

    mented with ASPC 2.The maximum transmission rate is12 Mbit/s.

    Design

    The ASPC 2 is accommodated in anMQFP 100 housing.

    A DP/PA link is required for intrinsicallysafe transmission to PROFIBUS-PA,since the synchronous transmissionmethod for IEC 1158-2 is not imple-mented in this ASIC.

    Operation

    The ASPC 2 handles the messageframe and address codes and databackup sequences.

    The PROFIBUS-DP and PROFIBUS-FMS protocols are handled completelyby the firmware.

    The ASPC 2 can address an external1 Mbyte message frame memory. Busaccess is hardware-driven.

    A separate microprocessor and theappropriate firmware are required foroperation. The ASPC 2 can be con-nected easily to all standard types ofprocessor.

    Features

    PROFIBUS-DP and PROFIBUS-FMSprotocols

    Maximum transmission rate12 Mbit/s

    RS 485 transmission Up to 125 active and passive nodes

    can be connected

    P-MQFP housing with 100 pins 16-bit data bus 1-Mbyte RAM addressable as exter-

    nal communications memory

    Services supported:Ident; request FDL status; SDN; SDA;

    SRD; SRD with distribution database;SM services

    2 interrupt lines 5 V DC power supply Maximum power loss 0.9 W.

    Firmware

    The firmware for the ASPC 2 handlesthe entire protocol processing and allfunctions required for a PROFIBUS-DPmaster connection.

    The firmware for PROFIBUS-DP is of-fered for device vendors within theframework of a license agreement.

    The firmware is suitable for the 80C165processor and is approximately80 Kilobytes in size.

    ASPC 2 80C165

    Flash EPROMOTP EPROM

    Dual-PortRAM

    Addressbus

    D0-15

    A0-13

    Fig. 8 Integration of the ASPC 2 ASIC in a master application

    ASPC 2 Communications Chip

    PROF

    IBUS-D

    Pfieldbus

    RS

    485driver

    with

    galvanicisolation

    Data bus

  • 7/28/2019 Interfacecomponent Siemens

    9/16

    9 9

    Application

    Various interface modules, based onthe PROFIBUS-DP ASICs describedabove, are available for master andslave applications.

    PROFIBUS-DP interface modules pro-vide third-party vendors with a simplemeans of connecting their productsand systems to the PROFIBUS-DPfieldbus.

    The advantage of these interface mod-ules is that they obviate the need to de-velop an additional external circuit.

    Different interface modules are avail-able for various functional require-ments and applications.

    Master interface modules

    The IM 180 enables the connection of athird-party device as master toPROFIBUS-DP. The maximum trans-mission rate is 12 Mbit/s.

    A PC carrier board with the product de-scription IM 181-1 is available for theIM 180 interface module. The boardcan be used as a short ISA card in aprogramming device or PC.

    Slave interface modulesThe IM 182-1 interface module is a sim-ple PC card for slave applications. It isdesigned for PCs with ISA bus. Themaximum transmission rate is12 Mbit/s.

    The IM 183-1 interface module enablesthe connection of a third-party deviceas a slave to PROFIBUS-DP. The maxi-mum transmission rate is 12 Mbit/s.

    The IM 184 interface module enablesthe connection of a simple slave toPROFIBUS-DP. The maximum trans-mission rate is 12 Mbit/s.

    Design

    The interface modules consist mainly ofan ASIC, if necessary, a microproces-sor for protocol handling as well as amemory.

    The interface from the interface mod-ules to the host system is implementedusing a multi-row connector strip.

    Operation

    The interface modules handle commu-nications tasks between the bus node(master or slave) and the PROFIBUS-DP network.

    Data exchange between the interfacemodule and the host system depends

    on the interface module, i.e. by using adual-port RAM, the address and databus, a serial interface or ports.

    Development kits

    The development kits let you developand test PROFIBUS hardware and soft-ware applications that use PROFIBUSASICs or Interface modules (IM) (seepages 14 and 15).

    The comprehensive hardware and soft-ware components contained in thepackages considerably reduce theeffort required to develop a PROFIBUSdevice.

    The packages feature a functionaldevelopment environment, which isable to accept your special hardwareand software requirements. Conse-quently our PROFIBUS know-how ismade available to others.

    Our development team will assist andsupport you in your development activ-ities. This support is included in thedevelopment kit.

    Subsequently you will be able to haveyour device certified in one of our spe-cialized integration centers.

    Addresses of our integration centers:

    PROFIBUS SchnittstellencenterCOMDecWrzburger Str. 121D-90766 Frth, GermanyTel.: 0911/750-2080, Fax: -21 00Mailbox: 0911/737-972.E-Mail: [email protected]

    PROFIBUS Integration Center3000 Bill Garland RoadJohnson City, TN 37605-1255, USATel.: (423)-461-2576, Fax. -2016Mailbox: (423)-461-2751E-Mail:[email protected]/pic

    Overview of Interface Modules, Development Kit

    IM 184

    IM 182-1 IM 183-1

    IM 180 IM 181-1

    Fig. 9 Classification of the interface modules according to application areas

    Masterapplications

    Intelligentslaveapplications

    Simpleslaveapplica-tions

  • 7/28/2019 Interfacecomponent Siemens

    10/16

    10 10

    Application

    The IM 180 interface module enablesthe connection of a third-party deviceas master to PROFIBUS-DP.

    The IM 180 interface module handlesthe entire bus control independently.

    The IM 180 takes the load of handlingcommunications from programmablecontrollers, personal computers, drivecontrols and human-machine inter-faces.

    The maximum transmission rate is12 Mbit/s.

    Design

    The IM 180 interface module consistsmainly of an 80C165 microprocessor,the ASPC 2 ASIC, a Flash EPROM andRAM.

    The ASPC 2 ASIC is controlled by a48 MHz oscillator chip.

    The interface module is 100 x 100 mm(3.9 x 3.9 in.) in size and suitable forface-to-face mounting.

    For the IM 180 interface module, a car-rier board is available. This board iscalled

    IM 181 and can be used as a short ISAcard in a programming device or PC.

    Operation

    The integrated ASPC 2 ASIC handlesthe bus protocol fully independently.

    Communication with the host systemtakes place via a dual-port RAM inter-face. Data exchange is handled by theuser program.

    The host software for the power supplyof the dual-port RAM must be createdby the user.

    Features

    Maximum transmission rate 12 Mbit/s PROFIBUS-DP protocol handling by

    ASPC 2 ASIC

    Module core80C165 microprocessor,40 MHz clock frequency;2 x 128K x 8-bit RAM user memory;256K x 16-bit flash EPROM programand parameter memory;

    48 MHz oscillator chip forASPC 2

    Host interface16/ 8-bit data bus can be connected;dual-port RAM (8K x 16 bit);64-pin connector (4 rows);optional 8/16-bit data bus connect-able

    High-integrity data exchange viadual-port RAM

    5 V DC power supply 0 to 70 C permissible ambient tem-

    perature

    Dimensions (W x H): 100 x 100 mm/3.9 x 3.9 in.

    Firmware

    The firmware is operated on the micro-processor and handles the entire pro-tocol processing as well as all functionsrequired for a master connection.

    Driver

    A corresponding driver is offered forWindows NT.

    Demonstration software

    The demonstration software for the IM180 / IM 181-1 shows in exemplarymanner how the dual-port RAM underthe MS-DOS operating system of theIM 180 interface module is suppliedand enables different operations of theIM 180 on the user interface.

    Configuring

    The IM 180 interface module can beeasily configured with COM PROFIBUSconfiguring software. The user doesnot have to create his own configuringtool.

    Fig. 10 Block diagram for IM 180 master interface module

    IM 180 Master Interface Module

    Connector

    stripforhostnetwork

    Processor80C165

    Flash EPROM256 K x 16

    Integritycontrol

    Dual-portRAM

    CS logicRAM2 x 128 K x 8

    ASICASPC 2

    Data bus

    Address bus

    D0-15

    A0-13

    RxD

    TxD

    RTS

    A0

  • 7/28/2019 Interfacecomponent Siemens

    11/16

    11 11

    Application

    The IM 184 interface module enablesthe simple connection of a third-partydevice as slave to PROFIBUS-DP.The maximum transmission rate is12 Mbit/s.

    IM 184 is designed for simple slave ap-plications such as sensors and actua-tors.

    Design

    The IM 184 interface module consistsmainly of the LSPM 2 ASIC, a socket forthe EEPROM and an RS 485 interface

    for connection to PROFIBUS-DP.

    LEDs are also provided for the operat-ing states RUN, BUS ERROR andDIAGNOSTICS.

    The LSPM 2 ASIC is controlled by a48 MHz oscillator chip.

    The interface is as small as a chequecard and suitable for face-to-facemounting.

    Operation

    The integrated LSPM 2 ASIC handlesthe PROFIBUS-DP bus protocol fully in-dependently.

    Communication with the host systemtakes place via a connector strip. Forthis purpose, the required input/outputsignals must be supplied to the con-nector strip.

    Customized settings are implementedusing jumpers.

    Features

    Maximum transmission rate 12 Mbit/s Automatic detection of the transmis-

    sion rate on the fieldbus

    PROFIBUS-DP protocol handling byLSPM 2 ASIC

    48 MHz oscillator chip forLSPM 2

    32 configurable inputs/outputs, ofwhich up to 16 can be used as diag-nostics inputs

    8 separate diagnostics inputs Connection

    2 x 34-pin connectors for connectionto host network10-pin connector for RS 485

    Floating RS 485 interface forPROFIBUS-DP

    Slot for EEPROM (64 x 16 bits) 5 V DC power supply Power consumption typ. 100 mA Polarity reversal protection 0 to 70 C permissible ambient

    temperature

    Dimension (W x H): 85 x 64 mm/3.3 x 2.5 in. (modular design).

    Firmware

    No firmware is required for the opera-tion of the IM 184 interface module.

    The entire protocol processing is han-dled by the ASIC on the interface mod-ule.

    Fig. 11 IM 184 slave interface module

    IM 184 Slave Interface Module

  • 7/28/2019 Interfacecomponent Siemens

    12/16

    12 12

    Application

    The IM 183-1 interface module enablesthe connection of a third-party deviceas slave to PROFIBUS-DP.

    The maximum transmission rate is12 Mbit/s.

    The IM 183-1 is designed for intelligentslave applications.

    Design

    The IM 183-1 interface module consistsmainly of the SPC 3 ASIC, the 80C32microprocessor, an EPROM and RAM

    memory and an RS 485 interface forconnection to PROFIBUS-DP.

    An RS 232 interface is also provided onthe module for the connection of devic-es with an RS 232 interface, such asPCs, to the PROFIBUS-DP fieldbus.

    The SPC 3 ASIC is controlled by a48 MHz oscillator chip.

    The interface is as small as a chequecard and suitable for face-to-facemounting.

    Operation

    The integrated SPC 3 ASIC handles thebus protocol fully independently.

    Communication with the host systemtakes place via the address and databus which are routed to the connectorstrip. Data exchange is handled by theuser program.

    The 80C32 processor enables the ad-ditional integration of applications.

    Features

    Maximum transmission rate 12 Mbit/s Automatic detection of the transmis-

    sion rate on the fieldbus

    PROFIBUS-DP protocol handling by

    SPC 3 ASIC Module coreCPU 80C32 microprocessor,20 MHz clock frequency;32 Kilobytes SRAM user memory;32 Kilobytes or 64 Kilobytes EPROMprogram memory

    48 MHz oscillator chip for SPC 3 The host interface is the address and

    data bus on the interface module

    Connection50-pin connector for connection tohost network;14-pin connector for RS 232;10-pin connector for RS 485

    Software reset for ASIC SPC 3 5 V DC power supply Power consumption typ. 100 mA Floating RS 485 interface for

    PROFIBUS-DP

    0 to 70 C permissible ambient tem-perature

    Dimensions (W x H): 86 x 76 mm/3.3 x 2.7 in. (modular design).

    Firmware

    Firmware (source code in C program-ming language) is supplied as an inter-face between the registers of the SPC 3and the application.

    The firmware is operated on the micro-processor and provides call interfacesfor simple integration of the application.

    The firmware contains approximately4 to 24 kilobytes including examples.

    The firmware is not absolutely neces-sary to operate the IM 183-1 interfacemodule with the DP standard functions,since the registers of the ASICs SPC 3are precisely documented. The firm-ware enables the user to save time hewould otherwise require for develop-ment work.

    The firmware is required for the use ofthe additional DPV1 DP functions (read

    / write data set).

    IM 183-1 Slave Interface Module

    Fig. 12 IM 183-1 slave interface module

  • 7/28/2019 Interfacecomponent Siemens

    13/16

    13 13

    Application

    The IM 182-1 interface module is a sim-ple PC card for PROFIBUS-DP slaveapplications.

    The 182-1 is designed for PCswith ISA bus.

    The maximum transmission rate is12 Mbit/s.

    Design

    In principle, the IM 182-1 consists ofthe SPC 3 ASIC as well as an RS 485interface for connecting a PROFIBUS-

    DP.SPC 3 ASIC is controlled by a48 MHz oscillator chip.

    Operation

    The integrated ASIC SPC 3 carries outthe PROFIBUS-DP bus protocol com-pletely independently.

    The RAMs ASIC or the firmware mustbe linked by the user into his/her appli-cation.

    Features

    Maximum transmission rate 12 Mbit/s PROFIBUS-DP protocol handling by

    SPC 3 ASIC

    48 MHz oscillator chip for SPC 3 Isolated RS 485 interface for

    PROFIBUS-DP

    Isolated power supply for the RS 485interface on board

    DIP switch for setting the addressspace of the I/O addresses and theinterrupt cables

    5 V DC power supply Power consumption typ. 250 mA

    0 to 60 C permissible ambient tem-perature.

    Firmware

    A firmware (in the ANSI C source code)is offered as an interface between theregisters of the SPC 3 and the applica-tion.

    The firmware is operated on the micro-processor of the host system and offerscall interfaces for easy linking of theIM182-1.

    The firmware contains approximately4 to 24 Kilobytes including examples.

    The firmware is not absolutely neces-sary to operate the IM 182-1 interfacemodule with the DP standard functions,since the registers of the ASICs SPC 3are precisely documented. The usersaves time which would otherwise bespent for the required developmentwork.

    The firmware is required for the use ofthe additional DPV1 DP functions(read / write data set).

    Driver

    A corresponding driver is offered forWindows NT.

    Fig. 13 Block diagram for IM 182-1 slave interface module

    IM 182-1 Slave Interface Module

    PROF

    IBUS-D

    Pfieldbus

    Quartz48 MHz

    RS

    485driver

    with

    galvanicisolation

    SPC 3Data andaddress

    INT

    WR/RD

    ResetIS

    A

    busofPC/PG

  • 7/28/2019 Interfacecomponent Siemens

    14/16

    14 14

    Application

    The development kit 4 offers you evalu-ation and development of Master andSlave applications for PROFIBUS-DP.

    Supported target systems:

    Master interface module IM 180/181 Slave interface module IM 183-1 Slave interface module IM 184 Slave-ASIC SPC3

    Hardware components

    Master interface module IM 180 andcarrier board IM181

    Slave interface module IM 183-1,(intelligent slave, with ASIC SPC3)

    Slave interface module IM 184,(simple slave, with ASIC LSPM2)

    Bus connector and bus cable

    Software components

    COM PROFIBUS,(needed to configure the bus systemand the interface module IM 180)

    Firmware for IM 183-1(original firmware for ASIC SPC3, in-cluding development licence)

    Simulation software,(to test and operate the components)

    Documentation

    A complete English and German set isincluded on the accompanying CD.

    Development of Slaves

    The purpose of the development kit isto develop a PROFIBUS slaves withASIC SPC3 and LSPM2.

    Similarly, it is possible to developPROFIBUS slaves directly with theIM 183-1 or IM 184 (as a piggy-backunit in your own electronics).

    In order to establish a small, runningPROFIBUS network, you must plug themaster interface module IM 180 into thecarrier plate IM 181, and install it in aPC (ISA slot). Then, connect it with theslave interface module IM 183-1.

    The simulation software lets you assignparameters to the IM and control theslaves. As a result, you can quicklybecome acquainted with the designand functions of the field busPROFIBUS-DP.

    The simulation software is installed on

    the PC and enables you to control andquery the slaves through the Dual-Port-RAM of the IM 180. In the process, di-agnostic data of the slaves and inputscan be read, and slave outputs be set.

    The program examples exist in sourcecode, and are well-documented.

    Based on the examples, you can devel-op your own functioning software andhardware.

    Master systems with IM 180

    The IM 180, and the simulation soft-ware constitute an operative

    PROFIBUS master. Based on this, youcan quickly develop a master applica-tion.

    Proprietary master systems

    If the hardware basis is not the IM 180 in itsoriginal condition (piggy back), then youneed the ASPC2 master firmware set, withcorresponding licence. This software isavailable in object code and in sourcecode. The software was designed for the80C165 processor.

    The master licence and the firmware is notincluded in the development kit.Additional information is available inthe integration centers.

    Service

    The cost-free support of our customers,

    performed by the integration centers, isa constituent of the development kits.

    The addresses of our integration centersare shown in page 9.

    Fig. 14 Components of the development kit 4

    Development Kit 4

    Software components

    Personal Computeror programming device

    Configuring softwareCOM PROFIBUS

    Demo software

    Firmware

    Hardware

    IM 183-1 slave interfacemodule

    IM 180 master interfacemodule

    IM 184 slave interfacemodule

  • 7/28/2019 Interfacecomponent Siemens

    15/16

    15 15

    Application

    This development kit enables you toestablish PROFIBUS slaves matchingthe following PROFIBUS standards:

    PROFIBUS DPV1 (RS 485) PROFIBUS PA (IEC 1158) and PROFIBUS based on fiber-optic ca-

    bles

    Supported target systems:

    The development environment showsthe realization of applications with thePROFIBUS-ASICs DPC31.

    Also, the environment clarifies how theASICs SIM1, acting as a MediumAttachment Unit, is used to adapt thesystem to PROFIBUS-PA technologyaccording to IEC 1158-2t.

    Hardware components

    DPC31 Development Board;for developing, testing your own ap-plications

    CP5613the master interface module for thePC (PCI board)

    Optical bus terminalto interface copper wires with opticalcables

    PROFIBUS-DP cable, copper, pre-assembled, violet

    PROFIBUS-DP fiber optical cable;plastic, pre-assembled

    PROFIBUS-PA cable; blueSoftware components

    Test and simulation software for PCuse (under WinNT), in conjunctionwith master board CP5613

    Example program for the DPC31board, with easy-to-use user inter-

    face DPC31 original DPV1 firmware, in-cluding development licence

    Parameter assignment software"COM PROFIBUS" for CP 5613, forDP operation

    PDM demo software (PDM = ProcessDevice Manager) for PA operation

    PDM is a compatible and open tool forconfiguration purposes, parameterassignment, commissioning, and diag-nostics of intelligent process devices.The accompanying PDM demo soft-ware is a full version, with a 2 month

    runtime limitation. The licence can bebought later and will enable you to usethe PDM software after the runtime lim-itation has run out.

    Documentation

    The complete English and Germandocumentation is included on theaccompanying CD.

    Functions

    The development kit contains all com-ponents required to develop aPROFIBUS slaves with ASICs DPC31and SIM1.

    The program examples exist in sourcecode and are well documented. Thehardware configuration is documentedwith circuit diagrams.

    The CP 5613, which is included in thedelivery, must be installed in a PCI slotin the PC. Then, install the demo soft-ware (WinNT 4.0 required), to obtain afunctioning PROFIBUS-DP master. Usethe configuration tool "COMPROFIBUS" to assign parameters to theCP 5613 and to the PROFIBUS config-uration (with DPC31 board)".

    If you intend to develop a PROFIBUS-DP slave to RS 485, you must couplethe DPC31 board to the PC master byusing the copper PROFIBUS cableincluded in the delivery.

    If the line consists of optical cables,use the optical bus terminal (alsoincluded in the delivery) in order toconvert the interface to fiber optics.The accompanying fiber optic cablemust be connected to the optical inter-

    face of the DPC31 board.

    If the line is a PROFIBUS-PA line, theDPC31-Board must be connected overa DP/PA coupler. To achieve this, thesupplied PROFIBUS-DP cable must beplugged into the DP/PA coupler, and

    the supplied blue PROFIBUS-PA cablemust be wired from the DP/PA couplerto the PA port of the DPC31 board. ThePROFIBUS-PA devices must be config-ured with the supplied PDM software.

    The PROFIBUS DP/PA coupler(required if you wish to developPROFIBUS-PA applications) convertsthe PROFIBUS-DP technology toPROFIBUS-PA. It is not included in thekit and must be ordered separately.

    The example application is stored inthe firmware EPROM of the DPC31boards, and starts to communicate withthe master once the cables are con-nected properly.

    the software enables you to edit thefunctions included in the example, e.gby changing the limit values.

    Based on this operative example youcan develop your own hardware andsoftware.

    Service

    The cost-free support of our customers,performed by the integration centers, isa constituent of the development kits.

    The addresses of our integration cen-ters are shown in page 9.

    PROFIBUS DP/PA Development Kit

    Fig. 15 Block diagram of PROFIBUS DP/PA development board

    Internal/ExternalCrystal orOscillator

    Selection

    Socket for80C31Emulation

    64 kBFlash

    32 kBSRAM

    Host interface

    ExternalMicroprocessor

    Area for additionalapplications DIP switch

    DIP switch

    LEDs

    ASYNC

    PB

    P

    F

    MUX

    RS 485

    LIKO

    ASICSIM1

    Mode Configuration

    PROFIBUSDP

    PROFIBUSFiber Optic

    PROFIBUSPA

    Boot/bus

  • 7/28/2019 Interfacecomponent Siemens

    16/16

    Siemens AGAutomation and Drives GroupIndustrial Automation SystemsPostfach 4848, D-90327 NrnbergBundesrepublik Deutschland

    Siemens Aktiengesellschaft

    Siemens AG 2000Subject to change without prior notice

    Order No. 6ZB5310-0CT02-0BA7Printed in the Fed. Rep. of Germany261/001250 SB 01002.

    Technical SpecificationsASICs LSPM 2 SPM 2 SPC 3 SPC 41 DPC31 SIM 1 ASPC 2

    Application Simple slaveapplications

    Simple slaveapplications

    Intelligent slaveapplications

    Intelligent slaveapplications

    Intelligent slaveapplications

    Medium Man-agement Unit

    Masterapplications

    Transmission

    technology

    RS 485 RS 485 RS 485 RS 485

    IEC 1158-2

    RS 485

    IEC 1158-2

    IEC 1158-2 RS 485

    Transmission rate max. 12 Mbit/s 12 Mbit/s 12 Mbit/s 12 Mbit/s31.25 kbit/s atIEC 1158-2

    12 Mbit/s31.25 kbit/s atIEC 1158-2

    31.25 kbit/s 12 Mbit/s

    Automatic detection oftransmission rate

    Yes Yes Yes Yes Yes - -

    Protocols PROFIBUS-DP PROFIBUS-DP PROFIBUS-DP/ DPV1

    PROFIBUS-DP/DPV1PROFIBUS-FMS

    PROFIBUS-DP/DPV1

    PROFIBUS-DPPROFIBUS-FMS

    Bus access in ASIC in ASIC in ASIC in ASIC in ASIC - in ASIC

    Microprocessor reqd? No No Yes Yes No/Yes - 1 Mbyte (ext.)

    Size of firmware Not required Not required 4 to 24 Kbytes 8 to 40 Kbytes(lic. agreem.)

    4 to 24 Kbytes Not required 80 Kbytes(lic. agreem.)

    Msg. frame memory - - 1.5 Kbytes 2 Kbytes 6 Kbytes - Yes

    Power supply 5 V DC 5 V DC 5 V DC 5 V / 3.3 V DC 3.3 V DC 5 V DC 5 V DC

    Power loss max. 0.35 W 0.5 W 0.65 W 0.4 W (DP)0.01 W (PA)

    0.2 W (DP)5 - 10 mW (PA)

    0.009 W 0.9 W

    Permissible ambienttemperature

    -40 to +55 C -40 to +55 C(worst casewith max. load)

    -40 to +85 C -40 to +85 C -40 to +85 C -40 to +85 C -40 to +85 C

    Housing MQFP, 80 pin PQFP, 120 pin PQFP, 44 pin TQFP, 44 pin PQFP, 100 pin TQFP, 44 pin MQFP, 100 pin

    Housing size 4 cm2 10 cm2 2 cm2 2 cm2 4 cm2 2 cm2 4 cm2

    Delivery quanti ties 5/40/200/5.000/10 000

    items

    5/24/100/5.000/10 000

    items

    5/96/576/4.608/

    9 792 items

    5/96/960/4.800/10 560 items

    5/60/300/5.100/

    10 200 items

    5/96/960/4.800/10 560

    items

    5/66/660/4.620/

    9 900 items

    Interface module IM 184 IM 183-1 IM 182-1 IM 180 IM 181

    Application Simple slaveapplications

    Slaveapplications

    Slaveapplications

    Masterapplications

    Carrier board forIM 180 master inter-face module

    Transmission rate max. 12 Mbit/s 12 Mbit/s 12 Mbit/s 12 Mbit/s -

    Protocols PROFIBUS-DP PROFIBUS-DP PROFIBUS-DP PROFIBUS-DP -

    ASIC LSPM 2 SPC 3 SPC 3 ASPC 2 -

    Microprocessor Not required 80C32 (20 MHz) Processor of PC/PG 80C165 (40 MHz) -

    Size of firmware Not required 4 to 24 Kbytes (incl.

    test program)

    4 to 24 Kbytes (incl.

    test program)

    80 Kbytes -

    Memory capacity - 32 Kbytes SRAM64 Kbytes EPROM

    - 2 x 128 Kbytes -

    Host interface - - - Dual-port-RAM -

    Permissible ambienttemperature

    0 to 70 C 0 to 70 C 0 to 60 C 0 to 70 C -

    Power supply 5 V DC 5 V DC 5 V DC 5 V DC -

    Pwr consumption typ. 150 mA 250 mA 250 mA 250 mA -

    Board size 85 x 64 mm /3.3 x 2.5 in.

    86 x 76 mm /3.3 x 2.7 in.

    168 x 105 mm6.6 x 4.1 in.

    100 x 100 mm /3.9 x 3.9 in.

    168 x 105 mm /6.6 x 4.1 in.