Intensiv SA 6926 Montagnola Switzerland Tel. +41 91 986 50 50 Fax +41 91 986 50 59 [email protected] www.intensiv.ch Clinically tested and scientifically approved by the University of Zurich, Switzerland Intensiv UniglossCellbrush Never achieved high gloss and completely smooth surfaces of aesthetic restorations with polishing brushes due to new diamond-filled from hard to soft variable cellulose-filaments New! 5’000 rpm n UniglossCellbrush one-step high gloss polishing with hard filaments; 5000 rpm and slight pressure of 200 g; application after the 15 μm (yellow) rotating diamond instruments n The cellulose-filaments change through water absorption from hard to ultra-soft Preserves the operative achieved tooth anatomy (macro-morphology) (non destructive high gloss polishing) n UniglossCellbrush high gloss polishing with soft filaments; 5000 rpm and slight pressure n Adaptive to concave tooth morphology, totally atraumatic and preserves gingiva *scientifically approved by the University of Zurich, Switzerland n Adaptive to convex tooth-morphology; low vibration n Never achieved high gloss polishing results* with UniglossCellbrush Pat.Pend.EP10405114 0 5 10 15 20 25 30 35 40 P150E Slow speed & slight pressure = superior polishing results Filtek 320 grit = 46 μm + silicone polisher Tetric 320 grit = 46 μm + silicone polisher Vita Mark II 320 grit = 46 μm + silicone polisher Filtek 320 grit = 46 μm Tetric 320 grit = 46 μm Vita Mark II 320 grit = 46 μm Tetric 1200 grit = 14 μm new cellulose-filaments significant better high gloss Nylon-filaments with silcon carbide Gloss [gloss units]* Gloss [gloss units] Clinical pictures: Dr. Simona Giani, Varese, Italy
1

intensiv_uniglosscellbrush_flyer_e

Mar 22, 2016

Download

Documents

Intensiv SA

intensiv_uniglosscellbrush_flyer_e
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: intensiv_uniglosscellbrush_flyer_e

Intensiv SA6926 MontagnolaSwitzerland

Tel. +41 91 986 50 50Fax +41 91 986 50 [email protected]

Clinically tested and scientifically approved by the University of Zurich, Switzerland

Intensiv UniglossCellbrush

Never achieved high gloss and completely smoothsurfaces of aesthetic restorations with polishingbrushes due to new diamond-filled from hard to softvariable cellulose-filaments

New!

5’000rpm

n UniglossCellbrush one-step high glosspolishing with hard filaments; 5000rpm and slight pressure of 200 g;application after the 15 µm (yellow)rotating diamond instruments

n The cellulose-filaments changethrough water absorption fromhard to ultra-soft

Preserves the operative achieved tooth anatomy (macro-morphology) (non destructive high gloss polishing)

n UniglossCellbrush high glosspolishing with soft filaments;5000 rpm and slight pressure

n Adaptive to concave tooth morphology,totally atraumatic and preserves gingiva

*scientifically approved by the University of Zurich, Switzerland

n Adaptive to convex tooth-morphology;low vibration

n Never achieved high gloss polishingresults* with UniglossCellbrush

Pat.Pend.EP10405114

0

5

10

15

20

25

30

35

40

P150

E

Slow speed & slight pressure = superior polishing results

Filtek320 grit = 46 µm +

silicone polisher

Tetric320 grit = 46 µm +

silicone polisher

Vita Mark II320 grit = 46 µm +

silicone polisher

Filtek320 grit = 46 µm

Tetric320 grit = 46 µm

Vita Mark II320 grit = 46 µm

Tetric1200 grit = 14 µm

new cellulose-filamentssignificant better high gloss

Nylon-filaments with silcon carbide

Gloss [gloss units]*

Glo

ss [g

loss

uni

ts]

Clin

ical

pic

ture

s: D

r. Si

mon

a G

iani

, Va

rese

, Ita

ly