Intelli-FLEX™ Intelligent Fence Mounted Cable Type Sensor A Technological Breakthrough in Signal Processing for Cable- Type Sensors ARITECH ARITECH
Mar 30, 2015
Intelli-FLEX™ Intelligent Fence Mounted
Cable Type SensorA Technological Breakthrough
in Signal Processing for Cable-Type Sensors
ARITECHARITECH
Introduction
Intelli-FLEX™• Cable-type intrusion detection sensor
(Fence Mounted)– outdoor and interior applications
• Provides an alarm if an intruder– attempts to climb over the fence– attempts to cut through the fence– attempts to lift the fence fabric– attempts to penetrate wall (indoor version)
Typical Configuration
Dual zone deployment
Vocabulary
Glossary of terms• Zone
– The area or sector that is being monitored.
• Sensor cable– The proprietary coaxial transducer cable mounted on the
fence.
• Non-sensitive cable– RG59/u coaxial cable that connects the processor to the
sensitive cable.
• Processor– Outdoor mounted electronics required to analyze the
sensor cable disturbance.
Equipment List
Intelli-FLEX™ System Elements• Processor w/ enclosure and power
supply & battery charger• Program Module• Sensor Cable• Non-sensitive Cable• Splice Kit• Terminator Kit
Theory of Operation
• Triboelectric Effect–Minute movement (flexing) of the cable will
produce a transfer of charge between conductors in the passive sensor cable. This measurable signal is monitored at one end of up to 1000 feet (300 m) of cable
Supervision Circuits
Sensor cable supervision• Monitored by a small DC current• Terminated by a 1M ohm resistor (EOL)• If the cable is cut, shorted, or the
processor enclosure is tampered with, a supervision alarm will be generated
• Hall Effect” board mounted magnetic tamper switch.
Cable Splices
Terminator/Splice Kits• UV protected and
weather resistant• Connect sensitive
cable to non-sensitive cable, or sensitive cable to sensitive cable.
UPPER HALF SHELL
END CAP
LOWER HALF SHELL
TERMINAL BLOCK
Theory of Operation
Processor• Continually evaluates electrical signals
generated by the sensor cable, and converts the information to a digital format.
• Through “Adaptive Algorithms”, the processor will alarm if an intruders is trying to–Cut the fence fabric.–Climb the fence.– Lift the fence fabric.
Key Hardware Features
“Standard” Dual Zone Processor Microprocessor - Based Backward Compatibility Low Power Consumption Full Lightning Protection Handy Programming Module Optional Weather Station
Low Power Consumption
Only 70mA of current required for normal two zone operation
Small internal Gel Cel (.8AH) battery provides minimum 8 hour backup
State of the Art Lightning Protection
Gas discharge tubes and transzorbs on all inputs and outputs provide maximum protection against lightning
Backward Compatibility
Intelli-FLEX uses existing E-Flex Cable, Splices, Gate Kits and Tie Wraps
Microprocessor Based
A powerful Motorola 68HC11 Series processor resides within each Intelli-FLEX system
Contains onboard A/D converters, memory and I/O dedicated to analyzing fence disturbance signals
Enhanced Features
Separate Threshold Adjustments for Cut and Climb for each zone Extremely important in lowering nuisance alarm in demanding situations
“Learn Fence” Mode Internal Automatic Self Test
Key Software Features
Adaptive Algorithms™ Ambient Compensation Common Mode Rejection “Learn Fence” Mode Separate Cut & Climb Thresholds Cipher Protected Adjustments Optional Built-in Transponder
Theory of Operation
Processor (continued)• Operates on 20VAC or 12VDC.• Back-up battery provides over 8 hours
of operation during power failures.• Operationally tested from -30 o C to
+70 o C.
Adaptive Algorithms™
Sophisticated software code written to change or modify system parameters as new information is received
Ambient Compensation
Statistical analysis of digitized analog signals identifying properties inherent in wind & rain as they differ from cut & climb
Provides a “Dynamic Threshold” as weather events build, without sacrificing sensor performance or detection
Common Mode Rejection
An event “qualifier” that compares identical weather effects on adjacent zones to verify ambient compensation measures
Audio Option
Optional audio plug in board allows selection and monitoring of sensor cable signals.
Provides “Listen-in” capability On-board line amplifier Remotely switchable - Zone 1 or 2
Weather Station Option
Enclosure mounted weather sensor provides simple rain and wind verification to the processor via A/D converter
Multiplexer Option
Mux version of the Intelli-FLEX board provides data communication interface within the signal processor eliminating the requirement for outboard transponders or multiplexers
Theory of Operations
Options (continued)• Weather Station–Provides weather data so the processor
may make intelligent decisions.
• Self Test Terminator–Provides a permanent and convenient way
to test zones remotely. No external power or wiring is required.
Preparing for Installation
Installation Planning• Perimeter of installation• Perimeter structure• Mounting the processors• Monitoring and power wiring.
Preparing for Installation
Site Survey• Should be conducted before installing
any system hardware• To ensure optimum performance...
–Mounting surface should be as stable as possible.
– Fences must be cleared of vegetation and any other objects that disturb the structure.
–A good earth ground should be achieved for the sensor processor.
Preparing for Installation
Site Survey (continued)• Fence condition is critical to the
trouble-free and efficient operation of the Intelli-FLEX sensor.–All fence framework should meet or exceed
minimum specifications outlined in the installation manual.
Preparing for Installation
Determining a List of Materials• The Intelli-FLEX™ sensor system is
supplied in kits for installation convenience.–Single zone kits
–Dual zone kits
• All Intelli-FLEX hardware components may be purchased individually.
• Options enhance the overall effectiveness of secure facilities.
Typical Configuration
Processor installation (single zone)
SKJ-8(JUNCTION)
SENSOR TIE
(TERMINATOR)SK-8
NON-SENSITIVE
PROCESSOR
WRAPCABLE
CABLE
Installation
Junction devices• Moisture proof• Connects sensor cable to non-sensitive
feed cable, or sensor cable to sensor cable, and holds termination resistor/card.
UPPER HALF SHELL
END CAP
LOWER HALF SHELL
TERMINAL BLOCK
UPPER HALF SHELL
LOWER HALF SHELL
TERMINAL BLOCK
1M RESISTOR
Installation
Sensor cable• Mounted directly to the fence• May be mounted in conduit• Secured by UV protected tie wraps
every 12 inches (.3m)
INCORRECT CORRECT
Installation
Sensor Cable (continued)• Fences >8 feet (2.5 m) in height should
have double passes.
DOUBLE-PASSED FOR OPTIMUM DETECTIONFENCES OVER 8 FEET (2.5 METERS) HIGH MUST BE
1/3 HIEGHT
1/3 HIEGHT
1/3 HIEGHT
(TERMINATOR)
(JUNCTION)SK-8
SK-8
Installation
Sensor Cable (continued)• Fence at corner posts need additional
sensitivity due to the rigidness of the fence.
1/4 FENCEHEIGHT
HEIGHT1/4 FENCE
SENSOR CABLE AT 1/2 FENCE HEIGHT
LOOP
Installation
Gates• Protected gates
SK-8
RG-59 IN PVC CONDUIT 18" (46 CM) UNDERGROUND
Installation
Gates (continued)• Unprotected gates
SK-8
RG-59 IN PVC CONDUIT 18" (46 CM) UNDERGROUND
SK-8
Installation
Gates (continued)• Protected sliding gates may use EJ-8
Quick Disconnect Assembly
MALE CAP
HOSE CLAMP
SK-8EJ-8 FEMALE
CABLE TIE
CABLE TIE
EJ-8 MALE
CAPFEMALE
SK-8
Installation
Remote Self Test
Remote Test Option• Generator board (no local power req’d)
CAPEND
TB2
Circuit Card
Calibration
Configuration Module
Calibration
Program Module for Setup& Config
Calibration
Program Module Modes • Monitor mode–Operator can monitor the detection
activity for the indicated zone ant threat scenario.
• Configure mode–Operator can view and change the
Operating Parameters, and Functional Parameters while in this mode. No alarms are reported in this mode.
CalibrationFactory default Threat Assessment parameter settings
Zone Threat Operation Factory Setting
1 Cut Time Window 30 seconds
1 Cut Threshold 5
1 Cut Cut Count 4
1 Climb Time Window 20 seconds
1 Climb Threshold 5
1 Climb Climb Time 2 seconds
2 Cut Time Window 30 seconds
2 Cut Threshold 5
2 Cut Cut Count 4
2 Climb Time Window 20 seconds
2 Climb Threshold 5
2 Climb Climb Time 2 seconds