8/12/2019 Intelecool2
1/8
Liebert
C o s t E f f e c t i v e , F l e x i b l e A i r C o n d i t i o n i n g
F o r U n m a n n e d T e l e c o m m u n i c a t i o n
S h e l t e r s A n d O t h e r R e m o t e S t r u c t u r e s
Heat Removal/Environmental ControI n t e l e C oo l2
A REAL CHOICE FORTELECOM SHELTER PROTECTION
8/12/2019 Intelecool2
2/8
AIR CONDITIONING DESIGNED FOR TODAYS
TELECOMMUNICATIONS SHELTER NEEDS
Even though they look the same on the outside, telecommunications shelters have very different requirements. Redundant city
shelters can be produced inexpensively. Suburban and country shelters usually require greater reliability. And those sited well
away from civilization need both high levels of reliability and remote communications capacity.
So why is it that shelter air conditioners are all the same?
Theyre not, thanks to Liebert. The first name in protection for sensitive systems for more than 30 years,
Liebert has created the InteleCool 2 shelter air conditioning system.
Its not just a shelter air conditioner...its a custom-configured model that fits your exact needs and budget. Want
a bare-bones system at minimum cost? Consider the InteleCool 2, basic model. Want a top-of-the-line unit for that
vital remote shelter? Try the InteleCool 2, advanced system. Need a field replacement/upgrade of a 3 ton air conditioner
to 4 or 5 ton? Take the InteleCool 2 replacement/upgrade unit. Same name...very different shelter air conditioner.
In the next few pages, well show you how to custom-configure an InteleCool 2 for every application.
Liebert Means Legendary Reliability
Liebert invented high-reliability, precision-controlled
air conditioning for computers and computer rooms
more than 30 years ago. Today, the telecommunicationsindustry worldwide relies on Liebert products to protect
sensitive installations. Liebert air conditioning has more
installations and has logged more hours of vital system
protection than all of its competitors combined.
And we not only build quality protection...we keep it
running. Lieberts service network has maintenance and
support offices around the world, and a 24-hour dispatch
center. Many customers dont even know they had a
problem until after it was diagnosed and fixed.
A Perfe ct Ma tc h For
Many Critical Applications
In addition to a wide range of telecommunications
shelter applications, the InteleCool 2 can beused at virtually any site that requires reliable cooling
in a small, l ightweight package:
Cellular
Radio Paging
Microwave/Satellite
Earth Stations
PCS Services
Mobile/Modular
Electronic Equipment
Structures
8/12/2019 Intelecool2
3/8
Basic Cooling
For shelters that are less critical and located close to service capability,
minimum seasonal air conditioning is usually sufficient. Depending on the
application, single or redundant units may be used. A simple remote
monitoring capability may also be added.
Critical Shelters
Shelters with highly sensitive equipment and limited site access must keep
operating no matter what. These sites may require dual units, high-reliability
components such as a scroll compressor, energy saving capabilities such
as an economizer, heating, remote monitoring and switchover control.
The InteleCool 2 T-Pack is designed for these types of common
telecommunications shelters. This package includes the basic InteleCool 2
system with all of the most popular options including high and low pressure
switches, fan cycle control and low pressure bypass.
Special Locations
You dont always have a choice as to where to place a telecom shelter.
It may be located in an urban environment where noise, appearance and
other factors are important. Or it may be miles from nowhere on the side
of a mountainmaking absolute reliability an important requirement.
The InteleCool 2 is designed with the flexibility to match the multiple protection
needs of todays telecommunications industry. You pick the level of protection your
application requires and Liebert will configure an InteleCool 2 for you...
8/12/2019 Intelecool2
4/8
Painted steel or
aluminum cabinets
Optional Economizer
with spring-return
actuator
Copper-tube,
aluminum fin coils
Heavy-duty double
width blower
Choice of compressor
on right or left side
of unit
NOW YOU CAN CUSTOM-CONFIGURE
SHELTER AIR CONDITIONING TO YOUREX ACT NEEDS AND BUDGET
Maximum Flexibility Designed To Meet
Al l Your Sh el ter Co ol in g Requ ir em en ts
8/12/2019 Intelecool2
5/8
No more wondering why you paid for all those features you dont use...or lamenting that you could have
saved a lot of problems if you only added that one little feature when you had it installed.
This simple, seven-step process can determine your needsand configure protection to match those needs exactly.
1
Step 1: Cooling Capacity
The InteleCool 2 is offered in five
capacities ranging from 1.5 to 5 tons,
covering the needs of almost any
shelter. Options and configurations
are available so you can match the
features you need to the cooling
capacity that's required. 2
Step 2: Cabinet
The self-contained InteleCool 2
cabinets come with your choice of
painted steel or aluminum panels.
Painted steel panels are available
in a choice of four different colors.
The evaporator supply and return
openings match industry standard
dimensions for ease of installation.
3Step 3: CompressorThe InteleCool 2 offers a choice of compressors to match your specific reliability needs. A rugged
hermetic compressor is standard on the 1.5, 2 and 3 ton units. For applications requiring the
highest reliability and lower energy use, a scroll compressor is also available as an option on the
1.5, 2 and 3 ton sizes and is standard equipment on the 4 and 5 ton capacity models. With fewer
moving parts and continuous compression, the scroll compressor is 14% more efficient than
hermetic units. It operates at an EER level of 11.3 one of the highest in the industry. The scroll
compressor is also ideal in applications where noise is a factor thanks to its low noise and vibration.
Compressors can also be located on either the right or left side of the u nit to make it easier to service dual installations.
Almond
Bright White
Desert Brown
HermeticScroll
Aluminum
Tan
8/12/2019 Intelecool2
6/8
No EconomizerWhen outside
temperatures are
warmer than the inside
air, the Economizer is
closed and indoor air
is recirculated to
maintain proper cooling.
Full EconomizerThe Economizer takes
advantage of low
outdoor ambients,
drawing on this cool
air to maintain indoor
temperatures. The
result is cooling at
lower energy costs,
also saving wear oncomponents.
ModulatedIn Modulated mode,
the Economizer draws
cool outside air and
recirculates indoor air,
reducing compressor
run time.
5Step 5: Economizer Option
The InteleCool 2 can be equipped with an economizer
system that uses modulating dampers to draw in
filtered, outside ambient air for cooling when the exterior
temperature drops below a pre-set level. These outside air
temperature settings are field adjustable. The economizer
saves energy and reduces component wear.
4Step 4: Fresh Air Damper
If required by your application, this
feature allows the introduction of
outside air into the shelter by means
of a field-adjustable damper.
6
7Step 7: Monitoring and Communications
Many Liebert remote monitoring options are available
ranging from relatively simple contact-closure sensing
to the Liebert Tele 2 for more complete monitoring
and control. Liebert also provides 24-hour monitoring
and alarm dispatch capability from our Columbus, Ohio,
command center.
Step 6: Controls
The high quality thermostat senses
ambient temperature and compares it
to your predetermined requirements.
For the highest levels of reliability
and to minimize site downtime critical shelters can be equipped with
two InteleCool 2 units and an
autochangeover system that balances
runtime and automatically switches
from one unit to another in case of a
system failure. Dual operation can be
accomplished with either the Dual
Unit Control thermostat or the Tele2
control and monitoring system.
InteleCool 2 with optional common alarm feature
8/12/2019 Intelecool2
7/8
Swift, Simple Installation
When deadlines loom, a simple installation is worth
almost anything...mostly because you cant get one at
any price. The InteleCool 2 is the exception to the rule.
However you configure the InteleCool 2, it comes
from the Liebert factory wired, piped, charged with
refrigerant and factory-tested as a complete system.
Each standard unit is shipped with a Nationally
Recognized Testing Laboratory (NRTL) listing. If the
wall openings and electric service are in place, the
InteleCool 2 can be installed in as little as 30 minutes.
If you need to field replace/upgrade a 3 ton air conditioner
to 4 or 5 ton, take the ET3 Series (ET3xx) of InteleCool 2
Installation time is
minimized with
InteleCools
self-contained
packaging.
Industry-standard
evaporator supply
and return openings
allow the unit to be
placed quickly.
H
G
F
E
BRETURN
Ws
ASUPPLY
Wu
J
The ET3 Series ofInteleCool 2 isdesigned as a fieldreplacement/upgradeof a 3 ton air conditionerto a 4 or 5 ton usingexisting air openings.This allows a unit withmore cooling capacityto be installed quicklyand easily. No cuttingor sawing of theshelter is required.
Specifications
60Hz Models 95F Outdoor
Ambient ET018 ET024 ET036 ET048/ET348 ET060/ET360
Compressor Type Hermetic Scroll Hermetic Scroll Hermetic Scroll Scroll Scroll
80/67F 26.7/19.4C
Total BTU/H 19300 19200 23200 22400 33800 34600 46900 56000
Total kW 5.65 5.63 6.80 6.56 9.90 10.14 13.74 16.41
Sensible BTU/H 17200 17200 19100 18800 26100 26400 38400 41900
Sensible kW 5.04 5.04 5.60 5.51 7.65 7.74 11.25 12.28
75/62.5F 23.9/16.9C
Total BTU/H 17800 17900 21500 20900 31400 32300 43800 52400
Total kW 5.22 5.24 6.30 6.12 9.20 9.46 12.83 15.35
Sensible BTU/H 16600 16600 18400 18200 25300 25700 37300 40800
Sensible kW 4.86 4.86 5.39 5.33 7.41 7.53 10.93 11.95
Weight
(Standard Unit) lbs.(kg) 330 (150) 330 (150) 330 (150) 470( 213) 470 (213)
(Unit w/Economizer) lbs.(kg) 350 (159) 350 (159) 350 (159) 490( 222) 490 (222)
50Hz Models 95F Outdoor
Ambient ET017 ET023 ET035 ET047/ET347 ET059/ET359
Compressor Type Hermetic Scroll Hermetic Scroll Hermetic Scroll Scroll Scroll
80/67F 26.7/19.4C
Total BTU/H 16500 19200 19900 21600 28800 27700 39800 49000
Total kW 4.83 5.63 5.83 6.33 8.44 8.12 11.66 14.36Sensible BTU/H 14700 15800 16500 17100 22300 21900 32500 36000
Sensible kW 4.31 4.63 4.83 5.01 6.53 6.42 9.52 10.55
75/62.5F 23.9/16.9C
Total BTU/H 15300 18000 18400 20100 26800 25900 37200 45900
Total kW 4.48 5.27 5.39 5.89 7.85 7.59 10.90 13.45
Sensible BTU/H 14200 15300 15900 16600 21700 21300 31600 35100
Sensible kW 4.16 4.48 4.66 4.86 6.36 6.24 9.26 10.28
Weight
(Standard Unit) lbs.(kg) 330 (150) 330 (150) 330 (150) 470( 213) 470 (213)
(Unit w/Economizer) lbs.(kg) 350 (159) 350 (159) 350 (159) 490( 222) 490 (222)
Model Wu Ws Wf A B E F G H J
1.5/2 Ton 37.1(943) 17.8(451) 38.8(984) 20.0(508) 20.0(508) 8.0(203) 20.8(527) 12.0(305) 25.1(638) 69.8(1772)
3 Ton 37.1(943) 17.8(451) 38.8(984) 28.0(711) 28.0(711) 8.0(203) 18.0(457) 14.0(356) 26.0(660) 69.8(1772)
4/5 Ton with 3 ton openings 4 1. 0( 10 41 ) 2 2. 5( 57 2) 4 2. 75 (1 08 6) 3 0. 3( 76 8) 2 8. 0( 71 1) 8 .0 (2 03 ) 1 8. 0( 45 7) 1 4. 0( 35 6) 3 7. 5( 95 2) 8 3. 0( 21 08 )
Wu= unit width Wf=width to flange edges A=height to top of flange
Shaded areas ina recommendeclearance of 34in front and 30each side or 36each side when adjacent to anotfor component arecommended mclearances referinstallation man
8/12/2019 Intelecool2
8/8
The Liebert Experience
L I E B E R T C O R P O R A T I O N
1050 DEARBORN DRIVE
P.O. BOX 29186
COLUMBUS, OHIO 43229
800.877.9222 PHONE (U.S. &
CANADA ONLY)
614.888.0246 PHONE (OUTSIDE U.S.)
614.841.6022 FAX
VIA LEONARDO DA VINCI 8
ZONA INDUSTRIALE TOGNANA
35028 PIOVE DI SACCO (PD)
ITALY
39 049 9719 111 PHONE
39 049 5841 257 FAX
EMERSON NETWORK POWER ASIA PACIFIC
7/F., DAH SING FINANCIAL CENTRE
108 GLOUCESTER RD, WANCHAI
HONG KONG
852 25722201 PHONE
852 28029250 FAX
L I E B E R T W E B S I T E
http://www.liebert.com
2 4 X 7 T E C H S U P P O R T
800 222 5877 PHONE
614 841 6755 (OUTSIDE U.S.)
While every precaution has been taken to ensure accuracy andcompleteness in this literature, Liebert Corporation assumes noresponsibility, and disclaims all liability for damages resultingfrom use of this information or for any errors or omissions.
2004 Liebert Corporation. All rights reserved throughoutthe world. Specifications subject to change without notice.
All names referred to are trademarks or registered trademarksof their respective owners.
Liebert and the Liebert logo are registered trademarksof the Liebert Corporation.
Keeping Business in Business is a registered trademark
of the Liebert Corporation.The Emerson logo is a trademark and service markof Emerson Electric Co.
SL-19500 (R3/04)Printed in USA
Heat Removal/Environmental Contro
No organization in the world today has a better understanding of exactly what it takes to keep critical
information and industrial processes operating continuously than Liebert.
We are the only company in this business that maintains a strong local presence of
Representatives, Distributors and Resellers. This resource, coupled with our broad product
line, gives Liebert the ability to create a "tailored solution" that will meet your protection
needs precisely and efficiently.
There are Liebert systems designed for nearly every application from basic protection for
network PCs, servers or point-of-sale terminalsto highly engineered systems for computerrooms, telecommunications centers, Internet hosting sites, colocation facilities and industrial
control rooms. But no matter what the size or complexity, the availability of these critical
electronic systems is Lieberts primary focus.
With your purchase of a Liebert product, you are buying into a company that stands behind its
products. You are also aligning yourself with an organization that has a reputation for quality
and reliability that is second to none.
After the sale, Liebert provides comprehensive support wherever and whenever it's needed,
with the largest service organization in the industry.
In the systems protection business it's when you need someone to count on that you find outwhether youve made the right choice. Liebert customers many of them with us for over three
decades already know how good their decision was.
TOTAL CONFIDENCE IN
THE DECISION YOU'VE MADE.
That Is
I n t e l e C oo l2
The day your critical operations arethreatened by excessive heat, powerproblems or other risks is no time tofind out if a "simple" solution to systemprotection will work. Let Liebert helpyou make the smart decision aboutassuring reliability in your highavailability facilities.
ISO 9000
CERTIFIED
COMPANY