16 Software • BIOS, Drivers, and Operating System Installation A. Confirm BIOS Version: Look on the Server/System Management screen in the BIOS Setup Utility to determine the installed BIOS version. Compare this to the versions at: http://www.intel.com/support/motherboards/server. If new versions are available, update the BIOS on your server. See the Technical Product Specification on the Intel ® Server Deployment Toolkit CD for update instructions. B. Configure your RAID Controller: Use the instructions provided with the RAID controller. C. Install your Operating System: Use the instructions provided with the RAID controller and with the operating system. D. Install Operating System Drivers: With the operating system running, insert the Intel ® Server Deployment Toolkit CD. If using a Microsoft Windows* operating system, the Intel ® Deployment Assistant will autorun and allow you to select the appropriate drivers to install. On other operating systems, browse the CD folders to locate and install the driver files. Side 2 9 Install Optical Drive and Hard Drive(s) See the documentation that came with your server chassis for drive installation. 14 Install Add-in Card[s] See the documentation that came with your server chassis for add-in card installation. For the Intel ® Server Chassis P4000 series, see the Quick Start User's Guide accompanying the chassis. 15 Finishing Up Before installing your operating system, you must finish your chassis installation, make I/O connections and plug in AC power. See your chassis documentation for AC power and grounding requirements. CAUTION: See your chassis documentation for AC power and grounding requirements. Network USB 0-1 USB 2-3 NIC1 10/100/ 1000 Mb NIC2 10/100/ 1000 Mb Video Serial A Common Problems and Solutions The system does not boot or show video at power-on stage. Check that the +12V CPU power connector is plugged in. The processors will not have any power without this cable. Only Intel ® Xeon ® E3-1200 processors, the 2 nd Generation Intel ® Core™ i3 processors, Intel ® Xeon ® E3-1200 V2 processors or the 3 rd Generation Intel ® Core™ i3 processors with 95W and less Thermal Design Power (TDP) are supported on this server board. Previous generation Intel ® Xeon ® processors are not supported. Beep code 1-5-2-1 in a system means you do not have the supported processor installed. The system generates the memory error beep code and POST diagnostic LED message {0XE0~0XEF} that indicates memory errors in early POST. Remember, all DIMMs must be: DDR3 1066/1333/1600 MHz UDIMM. From the same manufacturer. Installed beginning with DIMM A1. For a list of hardware components that have been tested with this system, see: http://www.intel.com/support/motherboards/server. 10 Connect Hard Drives/Optical Drive to Server Board Connect SATA Data Cables to server board here. Begin cable connections at the SATA 0 location. NOTE: SATA 0 and SATA 1 are 6Gb/s SATA port Server Board SATA Data Cable Connector Server Board 1 0 5 3 4 2 11 Attach Intrusion Switch Cable NOTE: For a non-Intel ® chassis, see your chassis documentation for intrusion switch requirements. Server Board Intrusion Switch Connector IMPORTANT NOTE: Return to your Intel ® Server Chassis Quick Start User's Guide, or your non-Intel ® chassis documentation to finish installation and configuration of your Intel ® Server Board S1200BTL and S1200BTLRM. Return to this document to finish up, including software, BIOS, drivers and operating system installation. 1 2 Attach Front Panel, Serial, and USB Connections NOTE: For a non-Intel ® chassis, see your chassis documentation for front panel features and server board connection requirements. Internal USB/Serial Connector Detail Serial B USB 10-11 USB 4-5 Front Panel USB Floppy USB Connector Detail 13 Chassis Fan Connections For a non-Intel ® server chassis, see the "Making Connections...Quick Reference" section below, and the documentation accompanying your chassis for specific chassis fan connection requirements. Attach fans with 4-pin connectors here. Server Board 7 Install DIMM Memory Modules To Install DIMMs: DDR3 DIMM Memory Identification: Open both DIMM socket levers. Push down firmly on the DIMM until it snaps into place and both levers close. Insert DIMM making sure the connector edge of the DIMM aligns correctly with the slot. C A D IMPORTANT! Visually check that each latch is fully closed and correctly engaged with each DIMM edge slot. E Note location of alignment notch. B CAUTION: Avoid touching contacts when handling or installing DIMMs. DIMM notch and socket bump must align as shown. Other Memory DDR3 This server board supports up to 4 DDR3 1066/1333/1600 ECC UDIMM. CAUTION: Observe normal ESD (ElectroStatic Discharge) procedures to avoid possible damage to system components. Memory Configurations and Population Order: Memory Type: Minimum of one 1 GB, DDR3 1066/1333/1600 MHz ECC UDIMM. A C D B E Note: For additional memory configurations, see the Technical Product Specification on the Intel ® Server Deployment Toolkit CD that accompanied your Intel ® Server Board S1200BTL and S1200BTLRM, or go to: http://www.intel.com/support/motherboards/server. Memory sizing and configuration is supported only for qualified DIMMs approved by Intel ® . For a list of supported memory, see the tested memory list at http://serverconfigurator.intel.com/default.aspx. DIMM A2 DIMM A1 DIMM B2 DIMM B1 Intel ® Server Board S1200BTL and S1200BTLRM Component Layout Note: Not all components, jumpers and connectors are described in this diagram. Refer to your Server Board Technical Product Specification on the Intel ® Server Deployment Toolkit CD for additional information. DIMM_A2 DIMM_A1 DIMM_B2 DIMM_B1 Serial B Internal USB SATA 5 SATA 2 SATA 1 SATA 0 Internal USB Floppy Connector Internal USB Front Panel Connector SATA 4 SATA 3 IPMB SAS Module Connector Internal USB SSD SATA_SGPIO SYS FAN_3 SYS FAN_1 SYS FAN_2 Processor Socket CPU Fan Connector RMM NIC CMOS battery Main Power Connector P/S AUX CPU Power Connector NIC2 USB2 USB3 NIC1 USB0 USB1 Serial Port A Video Diagnostic/ Status LEDs ID LED SYS FAN_4 Note: Refer to the Technical Product Specification for Diagnostic LED decoder list. HSBP J1F3 BIOS Recovery J1E2 CMOS Clear J4A2 BMC Force Update J1F1 Password Clear J1F2 ME Force Update Slot 1 ( PCI ) Slot 3 ( PCIe x 4 ) Slot 4 ( PCIe x 4 ) Slot 5 ( PCIe x 4 ) Slot 6 ( PCIe x 8 ) LP Riser Chassis Intrusion RMM4 Lite SATA Key TPM HDD LED Document/Tool Available Documents Technical Product Specification Monthly Specification Update Spares, Parts List, and Configuration Guide Sever Configurator Tool Software and Drivers Content In-depth technical information Technical information and issues update Supported accessories and spares list Tested peripherals and operating systems list Tested memory list Supported processors list Up-to-date firmware, driver and utility information Additional Reference documents available at: http://www.intel.com/support/motherboards/server A complete list of accessories and spares can be found at: http://www.intel.com/support/motherboards/server. (Search for the document Spares and Configuration Guide.) Making Connections to the Server Board ... Quick Reference = Make this connection = Make this connection D. System Fan 1 Header E. System Fan 2 Header F. System Fan 3 Header G. System Fan 4 Header Intel ® Server Chassis P4000 series CPU/System Fan Connections A. +12V CPU Power Connector B. Main Power Connector C. Front Panel Header Required Connections Intel ® Server Chassis P4000 series = Make this connection Optional Connections I. HSBP J. USB 4-5 10-11 K. SATA Connectors L. Serial B M. Chassis Intrusion Header N. IPMB O. SATA SGPIO P. Internal USB SSD Q. SAS Module Header R. USB Floppy S. P/S Auxiliary T. SATA Key U. RMM4 Lite V. RMM4 NIC W. TPM X. HDD LED Intel ® Server Chassis P4000 series H. CPU Fan Header IMPORTANT Note: Cables should be tied for better airflow. Use cable-ties compulsarily. C Front Panel DIMM A2 DIMM A1 DIMM B2 DIMM B1 Serial ATA K R USB J 4-5 10-11 USB Floppy Main Power 12V CPU Power A Intrusion M RMM4 Lite U SATA Key T IPMB N SATA SGPIO O HDD LED X RMM4 NIC V HSBP I Serial B L TPM W Int. USB SSD P SAS Module Q B CPU Fan 1 H Sys Fan 3 Sys Fan 1 Sys Fan 2 D F E G Sys Fan 4 P/S AUX Power S NOTE: For a non-Intel ® Chassis, see your chassis documentation for server board connection information. NOTE: Not all optional connections are shown in this diagram. Refer to your Server Board Service Guide, and your server chassis documentation for additional connection information. 8 Make Server Board Power Connections Attach the CPU power connector. Attach the main power connector. IMPORTANT NOTE: If you are using a non-Intel ® server chassis with an ATX power supply, see the documentation that came with your chassis for installation information. CAUTION: Note the location of the latch on each power cable connector and align it with the matching tab on each server board socket. A B Attach the P/S Auxiliary power connector. C Main Power Connector Detail B Latch Tab CPU Power Connector Detail A P/S auxiliary Power Connector Detail Latch Tab C Accessories and Order Codes Intel ® Remote Management Module 4 Intel ® SAS Entry RAID Module Intel ® Integrated RAID Module Intel ® Integrated RAID Module AXXRMM4 Intel ® Remote Management Module 4 Lite Intel ® Trusted Platform Module AXXRMM4Lite AXXTPME3 AXX4SASMOD AXXRMS2AF040 AXXRMS2LL040 Additional Reference documents available at: http://www.intel.com/support/motherboards/server. ATX I/O Shield AXXTIO SATA Slim-Line DVD AXXSATADVD Intel® Integrated RAID Module RMT3PB080 Intel® Integrated RAID Module RMS25PB080 Intel® Integrated RAID Module RMS25PB040 Intel® Integrated RAID Module RMS25KB080 Intel® Integrated RAID Module RMS25KB040
1

Intel® Server Board S1200BTL Quick Start User’s Guide · Title: Intel® Server Board S1200BTL Quick Start User’s Guide Author: Intel Corporation Created Date: 7/6/2012 1:50:19

Dec 21, 2018

Download

Documents

truongnga
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: Intel® Server Board S1200BTL Quick Start User’s Guide · Title: Intel® Server Board S1200BTL Quick Start User’s Guide Author: Intel Corporation Created Date: 7/6/2012 1:50:19

16 Software • BIOS, Drivers, and Operating System Installation

A. Confirm BIOS Version: Look on the Server/System Management screen in the BIOS Setup Utility to determine the installed BIOS version. Compare this to the versions at:http://www.intel.com/support/motherboards/server.If new versions are available, update the BIOS on your server. See the Technical Product Specification on the Intel® Server Deployment Toolkit CD for update instructions.

B. Configure your RAID Controller: Use the instructions provided with the RAID controller.

C. Install your Operating System: Use the instructions provided with the RAID controllerand with the operating system.

D. Install Operating System Drivers: With the operating system running, insert theIntel® Server Deployment Toolkit CD. If using a Microsoft Windows* operating system, the Intel®Deployment Assistant will autorun and allow you to select the appropriate drivers to install. On other operating systems, browse the CD folders to locate and install the driver files.

Side

2

9 Install Optical Drive and Hard Drive(s)

See the documentation that came with your server chassis for drive installation.

14 Install Add-inCard[s]

See the documentation that came with your server chassis for add-in card installation.

For the Intel® Server Chassis P4000 series, see the Quick Start User's Guide accompanying the chassis.

15 Finishing UpBefore installing your operating system, you must finish your chassis installation, make I/O connections and plug in AC power.See your chassis documentation for AC power and grounding requirements.

CAUTION: See your chassisdocumentation for AC power and grounding requirements.

Network

USB0-1

USB2-3

NIC110/100/

1000 Mb

NIC210/100/

1000 Mb

VideoSerial A

Common Problems and SolutionsThe system does not boot or show video at power-on stage.

• Check that the +12V CPU power connector is plugged in. The processors will not have any power without this cable.

• Only Intel® Xeon® E3-1200 processors, the 2nd Generation Intel® Core™ i3 processors, Intel® Xeon® E3-1200 V2 processors or the 3rd Generation Intel® Core™ i3 processors with 95W and less Thermal Design Power (TDP) are supported on this server board. Previous generation Intel® Xeon® processors are not supported. Beep code 1-5-2-1 in a system means you do not have the supported processor installed.

• The system generates the memory error beep code and POST diagnostic LED message {0XE0~0XEF} that indicates memory errors in early POST.

• Remember, all DIMMs must be: – DDR3 1066/1333/1600 MHz UDIMM. – From the same manufacturer. – Installed beginning with DIMM A1.

For a list of hardware components that have been tested with this system, see:http://www.intel.com/support/motherboards/server.

10 Connect Hard Drives/OpticalDrive to Server Board

Connect SATA Data Cablesto server board here.

Begin cable connectionsat the SATA 0 location.

NOTE: SATA 0 and SATA 1 are 6Gb/s SATA port

ServerBoard

SATA DataCable Connector

ServerBoard

1

0

5

3

4

2

11 Attach Intrusion Switch Cable

NOTE: For a non-Intel® chassis, see your chassis documentation for intrusion switch requirements.

ServerBoard

IntrusionSwitch

Connector

IMPORTANT NOTE: Return to your Intel® Server Chassis Quick Start User's Guide, or your non-Intel® chassis documentation to finish installation and configuration of your Intel® Server Board S1200BTLand S1200BTLRM.

Return to this document to finish up, including software, BIOS, drivers and operating system installation.

12 Attach Front Panel, Serial, and USB ConnectionsNOTE: For a non-Intel® chassis, see your chassis documentation for front panel features and server board connection requirements.

InternalUSB/SerialConnector

Detail

Serial B

USB 10-11

USB 4-5

Front Panel

USB Floppy

USBConnector

Detail

13 Chassis Fan Connections

For a non-Intel® server chassis, see the "Making Connections...Quick Reference"section below, and the documentation accompanying your chassis for specificchassis fan connection requirements.

Attach fans with 4-pin connectorshere.

ServerBoard

7 Install DIMM Memory Modules To Install DIMMs:DDR3 DIMM Memory Identification:

Open both DIMM socket levers.

Push down firmly on the DIMM until itsnaps into place and both levers close.

Insert DIMM making sure the connector edge of the DIMM aligns correctly with the slot.

C

A

D

IMPORTANT! Visually check that eachlatch is fully closed and correctlyengaged with each DIMM edge slot.

E

Note location of alignment notch.B

CAUTION: Avoid touching contacts when handling or installing DIMMs.

DIMMnotch and

socketbump must

align asshown.

OtherMemory

DDR3

This server board supports up to 4 DDR3 1066/1333/1600ECC UDIMM.

CAUTION: Observe normal ESD (ElectroStatic Discharge) procedures to avoid possible damage to system components.

Memory Configurations and Population Order:

Memory Type: Minimum of one 1 GB, DDR3 1066/1333/1600 MHz ECC UDIMM.

A

C

D B

ENote: For additional memory configurations, see the Technical Product Specification on the Intel® Server Deployment Toolkit CD that accompanied your Intel® Server Board S1200BTL and S1200BTLRM, or go to: http://www.intel.com/support/motherboards/server.Memory sizing and configuration is supported only for qualified DIMMs approved by Intel®. For a list of supported memory, see the tested memory list athttp://serverconfigurator.intel.com/default.aspx.

DIMM A2DIMM A1DIMM B2DIMM B1

Intel® Server Board S1200BTL and S1200BTLRM Component Layout

Note: Not all components, jumpers and connectors are described in this diagram. Refer to your Server Board Technical Product Specification on the Intel® Server Deployment Toolkit CD for additional information.

DIM

M_A

2DI

MM

_A1

DIM

M_B

2DI

MM

_B1

Serial B

InternalUSB

SATA 5

SATA 2SATA 1

SATA 0

Internal USBFloppy Connector

InternalUSB

Front PanelConnector

SATA 4

SATA 3

IPMBSAS ModuleConnector

InternalUSB SSD

SATA_SGPIOSYS FAN_3SYS FAN_1 SYS FAN_2

Processor Socket

CPU FanConnector

RMM NIC

CMOS battery

Main PowerConnector

P/SAUX

CPU PowerConnector

NIC2USB2USB3

NIC1USB0USB1

SerialPort A

Video

Diagnostic/Status LEDs

ID LED

SYS FAN_4

Note: Refer to the Technical Product Specificationfor Diagnostic LED decoder list.

HSBP

J1F3

BIOSRecovery

J1E2

CMOSClear

J4A2

BMCForce

Update

J1F1

PasswordClear

J1F2

MEForce

Update

Slot

1 (

PCI )

Slot

3 (

PCIe

x 4

)

Slot

4 (

PCIe

x 4

)

Slot

5 (

PCIe

x 4

)

Slot

6 (

PCIe

x 8

) LP

Rise

r

Chassis Intrusion

RMM4 LiteSATA Key

TPM

HDD LED

Document/ToolAvailable Documents

Technical Product SpecificationMonthly Specification UpdateSpares, Parts List, and Configuration Guide

Sever Configurator Tool

Software and Drivers

ContentIn-depth technical informationTechnical information and issues updateSupported accessories and spares list

Tested peripherals and operating systems listTested memory listSupported processors list

Up-to-date firmware, driver and utility information

Additional Reference documents available at:http://www.intel.com/support/motherboards/server

A complete list of accessories and spares can be found at:http://www.intel.com/support/motherboards/server.(Search for the document Spares and Configuration Guide.)

Making Connections to the Server Board ... Quick Reference

= Make this connection

= Make this connection

D. System Fan 1 HeaderE. System Fan 2 HeaderF. System Fan 3 HeaderG. System Fan 4 Header

Intel® Server ChassisP4000 seriesCPU/System Fan Connections

A. +12V CPU Power ConnectorB. Main Power ConnectorC. Front Panel Header

Required ConnectionsIntel® Server Chassis

P4000 series

= Make this connection

Optional Connections

I. HSBP J. USB 4-5 10-11K. SATA ConnectorsL. Serial BM. Chassis Intrusion HeaderN. IPMBO. SATA SGPIOP. Internal USB SSDQ. SAS Module HeaderR. USB FloppyS. P/S AuxiliaryT. SATA KeyU. RMM4 LiteV. RMM4 NICW. TPMX. HDD LED

Intel® Server ChassisP4000 series

H. CPU Fan Header

IMPORTANT Note:Cables should be tied for better airflow.Use cable-ties compulsarily.

CFront Panel

DIM

M A

2DI

MM

A1

DIM

M B

2DI

MM

B1

Serial ATA

K

R

USB

J 4-5

10-11

USB Floppy

Main Power

12V CPU PowerA

IntrusionM

RMM4 LiteUSATA Key

T

IPMB

N SATA SGPIO

O

HDD LED

X

RMM4 NIC

V

HSBP

I

Serial BL

TPMW

Int. USB SSD

P

SAS Module

Q

B

CPU Fan 1

H Sys Fan 3

Sys Fan 1Sys Fan 2

DF

E

GSys Fan 4

P/S AUX PowerS

NOTE: For a non-Intel® Chassis, see your chassis documentation for server boardconnection information.NOTE: Not all optional connections are shown in this diagram. Refer to your Server Board Service Guide, and your server chassis documentation for additional connection information.

8 Make ServerBoard PowerConnections

Attach the CPU power connector.

Attach the main power connector.

IMPORTANT NOTE: If you are using a non-Intel® server chassis with an ATX power supply, see the documentation that came with your chassis for installation information.

CAUTION: Note the location of the latch on each power cable connector and align it with the matching tab on each server board socket.

A

BAttach the P/S Auxiliary power connector.C

Main PowerConnector Detail

B

Latch

Tab

CPU PowerConnector Detail

A

P/S auxiliaryPower

Connector DetailLatch

Tab

C

Accessories and Order Codes

Intel® Remote Management Module 4

Intel® SAS Entry RAID Module

Intel® Integrated RAID Module

Intel® Integrated RAID Module

AXXRMM4

Intel® Remote Management Module 4 Lite

Intel® Trusted Platform Module

AXXRMM4Lite

AXXTPME3

AXX4SASMOD

AXXRMS2AF040

AXXRMS2LL040

Additional Reference documents available at: http://www.intel.com/support/motherboards/server.

ATX I/O Shield AXXTIO

SATA Slim-Line DVD AXXSATADVD

Intel® Integrated RAID Module RMT3PB080

Intel® Integrated RAID Module RMS25PB080

Intel® Integrated RAID Module RMS25PB040

Intel® Integrated RAID Module RMS25KB080

Intel® Integrated RAID Module RMS25KB040