Top Banner
Protect lives – secure values FIRE ALARM Fire alarm systems for the future INTEGRAL
16

INTEGRAL · With intelligent remote access, all Integral IP control panels can be monitored and operated at any time and from anywhere via computer, smartphone or tablet. The operating

Feb 05, 2021

Download

Documents

dariahiddleston
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
  • Protect lives – secure values

    FIRE ALARM

    Fire alarm systems for the future

    INTEGRAL

  • FIRE

    ALA

    RMUncompromising fire protectionat the highest level

    Safety is no coincidence – it is the result of many years ofexperience combined with innovative technology.

    There are no compromises in protecting people andproperty. Fire alarm systems must conform to highestquality standards and must work absolute reliable.The experts at Schrack Seconet develop products andsolutions that combine maximum safety with forward-looking concepts over the entire life cycle of a fire alarmsystem. An early and reliable fire detection system enablestargeted alerts and life-saving fire protection measuresthat are carried out effectively and automatically.

    The technologically advanced fire detection systems fromSchrack Seconet are used all over the world and aredeveloped and produced in Austria and Germany.

    FIRE

    ALA

    RM

  • Know-how and future-proof

    Schrack Seconet has a long tradition ofdeveloping reliable fire detection systems.Extensive investment in research anddevelopment, participation in internationalcommittees and collaboration with technicaluniversities, fire brigade associations andtesting institutes ensure that products areconstantly adapted to new requirements andoptimised for practical applications. Productswith the highest possible degree of forward andbackward compatibility ensure a future-proofinvestment.

    Anytime and anywhere

    With intelligent remote access, all Integral IPcontrol panels can be monitored and operatedat any time and from anywhere via computer,smartphone or tablet. The operating panel isthe same for all Integral IP panels andIntegral IP applications. Logical processes anda clear layout of keys provide the necessaryoverview in stressful situations.

    Fail-safe and reliable

    Full redundancy in hardware, software, powersupply and wiring supply ensures maximumavailability and absolute safety against failures.All functions, displays and controls areretained in full and remain reliable evenin the event of a fault.

  • Maximum reliabilitydue to full redundancy

    The task of a fire alarm system is to detect a fire at theearliest possible time and alert the emergency services.A broken cable, a short circuit or a defective electroniccomponent should under no circumstances interferewith this function. As the fire alarm system becomesbigger, it becomes more important that it is one hundredpercent reliable because there are more people that needto be evacuated and the potential loss is higher e.g.due to interruption of business operations.

    The unique fire alarm system Integral IP performs allfunctions and tasks reliably and without interruption,even in the event of a fault. In a consistent redundancyconcept, all the components of the fire alarm controlpanel are designed in duplicate, all conduction pathsare redundant and a highly innovative intelligencesystem is integrated to detect faults. This is the onlyway that a fire alarm system can achieve its purpose –protect lives and secure values.

    Redundant network

    The possibility of line interruptions – whichcould be caused by construction work on thepremises, expansions and modernisation or evena fire itself – cannot be ruled out. For this reason,all internal system connections and also the entirenetwork of Integral IP systems are implementedaccording to a redundancy system. In case ofconnection problems, the mesh networkautomatically and without interruption findsan alternative route. The system remainsfully active and there is ample time toproperly plan repairs and rectify anypossible malfunction.

    Redundant operation

    Clear information about the situation and abouteach event, as well as unrestricted operability ofthe entire fire detection and extinguishing systemare essential requirements for every situation. Forthis reason, connections and interfaces to externaloperating and indicator panels are duplicated.This form of redundant operating panel interfaceensures full operability of the system and a cleardisplay of all events, with clear informationregarding location and time, even in the event offailure of a line. Control panels in the fire alarmcontrol panel can thus be economised and operationtakes place where it is needed.

    FIRE

    ALA

    RMFI

    RE A

    LARM

  • Redundant loop

    All automatic fire detectors, manual call points, acousticand visual alarm devices and control modules areconnected in a loop system. Thanks to the short circuitisolator, which is without exception integrated into everyloop circuit device, the loop can be wired and configuredacross all fire sections and functions. If there is a shortcircuit, the integrated short circuit isolator disconnectsthe damaged part of the line, and all the devices on theX-LINE are connected via the remaining stub lines andremain fully functional – just as in the case of a wirebreakage. Accurate localisation of the damaged linesection facilitates troubleshooting and saves valuablecommissioning and service time.

    Redundant control panel

    All modules, power supplies, bus systems and softwareroutines of the Schrack Seconet Integral IP MX firealarm control panel are redundant. If the active sidefails, the second system – which constantly runs in“hot standby” mode – takes over automatically andwithout interruption. Any fault is thereforecompensated, no matter where it occurs. The fire alarmsystem always remains fully operational and fires canbe detected quickly and reliably, even in the event ofa fault. All data and messages are reliably conveyedand processed, and all fire control systems – e.g.ventilation flaps, fire compartment doors andextinguishing functions – are controlled.

    hot standby energy x 2wire break

    short circuitdata x 2processor x 2

    software x 2

    Bus x 2

  • Intelligent remote access for moreconvenience and efficiency

    Dongle

    * Use of the software also in the customer network

    Display and operation

    Integral Remote ProfessionalProgrammingby installer

    Integral Remote NotificationNotifications

    Integral Message*

    Integral Remote Control

    Integral Browser

    Be informed at any time and respond quickly.Remote access via Integral Remote offers amultitude of solutions: convenient monitoringdirectly at the workplace, mobile notificationsin real time on a smartphone or tablet,uncomplicated live support and much more.Information is delivered to where it is neededand provides a decisive time advantageto act – absolute safe and comfortable.

    Information and analysis

    The state of the fire alarm system can be viewedat any time, without the need to be on site.Detailed evaluations allow for exampleidentifying recurring deceptive alarms andtaking appropriate action.

    Flexible notification

    Push notifications provide quick and securemessages to computers or mobile devices,even when the applications are not active.Notifications can be addressed due to certainevents (alarm, fault, power failure etc.) andindividually to specified persons.

    Efficient operation

    Tasks during operation are solved moreefficiently. In the event of an alarm, explorationsteps can be initiated immediately andunnecessary fire brigade operations can beprevented. Detectors can be conveniently andtemporarily switched off during conversionwork, and much more.

    Live support

    Experts and technicians have access to the systemas required, and can quickly and easily provideremote assistance to local users.

    Remote programming

    Changes in the system configuration can beeasily realised by remote access. For example,adjustments of customer-specific texts dueto changes in use.

    FIRE

    ALA

    RM

  • Dongle

    Dongle

    S2service Connect• Connection management• Logging of events• Managing users and

    permissions

    possible

    Integral Mail*

    Integral Desktop*

    The multi-level security concept of Schrack Seconet

    Remote access with mobile devices via the Internet is known toinvolve security risks. Integral Remote is protected by a multi-levelsecurity concept with VPN tunnels, physical dongle accessprotection and a user-level authorisation concept for applications.All this takes place in the high-security data centre or in thecustomer-owned infrastructure.

    CERTIFICATE

    PC-VPN

    Router-VPN

    CERTIFICATE

    Integral Mobile

    CERTIFICATE

    PC-VPN

    Integral ApplicationCenter IAC*

  • Investment security due to compaflexible network solutions

    Integral LAN

    Larger buildings and complexes suchas hotels, office buildings, industrialplants etc. are efficiently fitted withan Integral LAN. Up to 16 controlpanels can be connected as desiredin a stub, loop or mesh topology toform a logical fire alarm control paneland can also be easily expanded later.

    Integral WAN

    Very large-scale systems or even facilities distantfrom one another require fire detection systemswith special network capabilities. With thepremium network, Integral WAN, previouslyimpossible system configurations that meet thehighest demands are now available. Systems growalong with buildings, and even older generationsof control panels can be easily integrated.

    Schrack Seconet ensures with its innovative and flexiblenetwork solutions that all investments in the fire alarmsystem remain economic and profitable for owners andinvestors over the entire life cycle of the system.

    The reduction in operating costs over the entire life cycleof the fire alarm system is achieved through the backwardcompatibility of the Integral IP system. Existingperipherals can be connected to the latest Integral IPcontrol panels. Accordingly, they remain in thefacility’s inventory and continue to be used.

    Thanks to their excellent network capabilities,Schrack Seconet fire alarm systems can be expandedas required and growing flexibly and modularlywith the requirements of the building.

    FIRE

    ALA

    RMFI

    RE A

    LARM

  • tibility and

    Building expansions

    With the premium networkIntegral WAN, control panels of differentgenerations can be interconnected.Expansions carried out using the latesttechnology are integrated effortlessly withexisting facility components. Extensionsand changes in the use of buildings canbe implemented flexibly at any time.

    SecoLOG IP

    In order to quickly make the right decisions indangerous situations, a complete overview of thecurrent situation and clear instructions are of crucialimportance. The professional fire alarm managementsystem SecoLOG IP (according to ÖNORM F 3003)is the perfect solution for simple, clear and centraldisplay and operation of fire alarm systems.

    Modernisation

    Schrack Seconet fire alarm systems provide ahigh degree of investment security, because oldergenerations of fire detectors can be connected to thelatest control panel technology of the Integral IP.Thus, migration to new technology without havingto replace existing installations of detectors andmodules is possible. This enables a gradual andeconomic modernisation and optimises the“total cost of ownership” over the entirelife cycle of the system.

    Different locations

    Integral WAN connects fire alarmsystems regardless of their distance.Complex networks – from companieswith branch structures such assupermarket chains or companies withmultiple branches, to unoccupied andscattered facilities such as wind farms –can be operated remotely.

    Large-scale systems

    Extensive premises with campusstructures, such as hospitals oruniversities, and large-scale facilities,such as shopping centres or large publicbuildings, can be optimally networkedwith an Integral WAN and can beefficiently managed via a central alarmmanagement system.

  • Customised componentsfor all applications

    FIRE

    ALA

    RMFI

    RE A

    LARM

    BX

    CXEMXE

    CXFMXF

  • External operatingand indicator panels

    The operating interfaces of the Integral IPsystems are continuously improved basedon customer needs and the requirementsof fire brigades and are available in morethan 20 languages. In addition to theIntegral IP control panels, there are alsomany variations and varieties of fire brigadecontrol panels available (e.g. accordingto ÖNORM F 3031, DIN 14662,SN 054 022 etc.), as well asLED indicator panels.

    Integral IP extinguishingcontrol panels

    The control panel types Integral IP MXEand Integral IP CXE can be used asextinguishing control panels according tothe standard (electrical control and delaydevice according to EN 12094-1 andVdS 2496) or as a combined fire alarm /extinguishing control panel.

    up to 32 1

    Structure

    Optimised for theprotection of

    Redundancy

    Loops per control panel

    Elements per control panel

    TCP/IP interface

    Networkable

    Modernisation ofexisting systems

    Floor standing cabinet

    Integral IP MXF

    modular, decentralised

    large systems andbuildings, for example,• Industrial facilities,• Office buildings,• Airports,• Hospitals,• Shopping centres, ...

    up to 16

    up to 4,000

    Integral IP CXF

    compact, decentralised

    medium-sized systems,for example,• Residential

    developments,• Large supermarkets,• Hotels, ...

    up to 4

    up to 1,000

    Integral IP BX

    basic

    smaller buildings,for example,• Unoccupied

    technical equipment,• Catering facilities,• Underground

    car parks, ...

    1

    up to 250

    via TCP/IP

    Suitable and approved formonitoring of

    Controlling single-zone extinguishing systems

    Controlling multi-zone extinguishing systems

    Number of extinguishing zones

    Additional parallel LED displays

    Additional freely programmableinputs and outputs

    • CO2 high pressure and low pressure extinguishingsystems with and without a danger to the safetyof people

    • Inert gas and argon extinguishing systems withand without a danger to the safety of people

    • Spraying water & misting water extinguishing systems• Pre-action sprinkler systems• Sprinkler systems• Chemical extinguishing systems

    Integral IP MXE Integral IP CXE

    Integral IP fire alarmcontrol panels

    The Integral IP system family consists ofdifferent control panels, housing variantsand components which can be perfectlycombined and matched to systems of anyconfiguration and size. All devices are basedon the same high-quality technology, arecompatible with each other and use thesame commissioning and software tools.The detectors and modules of the X-LINEcan be connected to all control panel types.The user interface is also identicalfor all Integral IP panels.

  • EN 54-3 Acoustic signalling device towarn people in the event of a fire(e.g. hotel rooms, public buildings)

    Heat detectors in areas where smoke isexpected to be a source of deceptivealarms (e.g. smoking areas)

    Smoke detectors in standard applications forrapid detection in the event of a fire withformation of smoke (e.g. office buildings)

    CO detector in the event of a fire with carbonmonoxide development for purely technicalalarms without forwarding to the fire brigade

    Combined CO and heat detectors in areas wheresmoke and heat are expected to be a source ofdeceptive alarms (e.g. industrial kitchens)

    EN 54-5

    EN 54-7

    EN 54-26

    EN 54-29

    EN 54-30

    Combined smoke and heat detectors whereshort-term disturbance such as smoke, dust,insects and steam can occur (e.g. warehouses)

    Settings according to EN 54

    Standard Typical applications

    Powerful X-LINEwith intelligent peripherals

    Fire detector family

    Fire detectors equipped with CUBUS detection technologyadapt actively, permanently, automatically and dynamically toatmospheric conditions. The individual parameters – like smoke,heat and CO – are not just measured, but always evaluatedin the context of the relative changes in the other relevantparameters. If there is a change in the atmospheric conditions,the sensitivity of the detector is automatically adjusted.FI

    RE A

    LARM

    FIRE

    ALA

    RM

    MTD 533X

    MTD 533X-S

    MMD 130 Ex-i

    CMD 533X

    MTD 533X-SP

  • Manual call points

    For manual triggering of a fire alarmaccording to EN 54-11, a variety of manualcall points (type A or B) are available indifferent versions and with different protectionclasses. The portfolio also includes manualcall points in other colours as well as stopand actuation buttons for manual triggeringan extinguishing operation.

    Input & output modules

    There are a large number of control modulesfor the connection of peripheral devices.Depending on the model, potential-freecontacts can be interrogated, hazardous areasmonitored, loads switched by relays, or specialfire alarm systems can be integrated.

    X-LINE

    The Integral X-LINE offers the perfect combination of detection and alerting. At a length of up to 3,500 meters,up to 250 high-performance and energy-efficient loop circuit devices can communicate with the fire alarm controlpanel. The short circuit isolator, which is integrated into every X-LINE device as standard, ensures planningsecurity as well as unlimited functioning in the event of a short circuit, wire break or sabotage.

    Signalling devices

    For acoustic and/or optical signallingof a fire, Schrack Seconet offers a variety ofsignalling devices in various colours anddesigns. All devices have an EN 54certification and/or a VdS-approval.In addition, there is a complete range offlashing lights that conform to theEN 54-23 European standard.

    Holding magnet

    The door holding magnet is used for automaticclosing of fire doors in the event of an alarm.Unlike with conventional magnets, this is notpermanently powered, but keeps the dooropen with a permanent magnet entirelywithout energy consumption.

  • Reliable detection under themost difficult conditions

    Config over Line

    Thanks to the unique “Config over Line”function, configuration, commissioning andmaintenance of special fire detectors thatare connected directly to the loop can becarried out quickly and conveniently fromthe control panel. Data exchange andcommunication take place via theexisting X-LINE.

    With the special fire alarm technologyproduct range, Schrack Seconet offersthe right solution for every application,thereby guaranteeing fire detection evenunder the most difficult atmosphericconditions, such as extreme airhumidity and pollution, hightemperatures and highaltitudes etc.

    Aspirating smoke detectors

    These are robust, durable and highly sensitiveto developing fires, suitable for fire protectionin high rooms and halls as well as for areasthat are hard to reach. They also offer anideal solution for technical infrastructuremonitoring, e.g. electrical cabinets,machinery for manufacturing technologyor computer systems.

    FIRE

    ALA

    RMFI

    RE A

    LARM

  • Flame detectors

    These are used to detect smokelessliquid and gas fires as well as smoke-intensive, open fires in hazardous areas.Typical applications are large industrialwarehouses, aircraft hangars, chemicalplants, oil refineries, engine rooms,power stations etc.

    The addressable LIST sensor cable ischaracterised by precise detection andhigh response speed, as well as easyinstallation and commissioning.Various sensor distances, branchesin the sensor cable and individualtemperature sensors provide theperfect solution for every application.

    Duct smoke detectors

    For fire detection inventilation systems or in placeswith high air velocity andstrong smoke dilution.Early smoke detection preventsfire and smoke from spreadingwithin and through theventilation system.

    Line-type heat detectors

    In extreme conditions such as heat, humidity,dust and steam or gas development, these proveto be particularly reliable. The robust temperaturesensing tube is ideal for high-temperatureapplications such as foundries, or areas withextreme temperature fluctuations such as industrialkitchens. Potentially explosive environments arebest protected by a special evaluation unit.

    Linear smoke detectors

    These are used where the maximuminstallation height of conventionalfire detectors is exceeded, the visualappearance may not be affected orlarge areas must be monitored,such as in high industrial, publicor historic buildings.

  • © S

    chra

    ck P

    rodu

    ctio

    ns -

    B-P

    R-6

    15E

    N -

    V 2

    .0 -

    05.

    2019

    S

    ubje

    ct t

    o te

    chni

    cal m

    odif

    icat

    ions

    !

    FIRE ALARM

    SCHRACK SECONET AGHeadquarter Austria: A-1120 Vienna, Eibesbrunnergasse 18 • Tel. +43 1 81157 • [email protected] • www.schrack-seconet.com

    Branch offices in Austria:A-6850 Dornbirn, Sebastianstraße 13a • Tel. +43 5572 51199A-8055 Graz, Neuseiersberger Straße 157 • Tel. +43 316 407676A-6020 Innsbruck, Dr.-Franz-Werner-Straße 36 • Tel. +43 512 365366A-9020 Klagenfurt, Eiskellerstraße 3 • Tel. +43 463 429362A-4060 Leonding-Hart, Kornstraße 16 • Tel. +43 732 677900A-5020 Salzburg, Vogelweiderstraße 44a • Tel. +43 662 887122

    Sales partners in:

    Czech Rep. • CZ-149 00 Prague 4 - Újezd., Štítová 283 • Tel. +420 2 74784422Hungary • HU-1119 Budapest, Fehérvári út 89-95 • Tel. +36 1 4644300India • IN-122102 Gurgaon, C-704A, Pioneer Urban Square, Sec-62 • Tel. +91 124 4141501Poland • PL-02-972 Warsaw, ul. Branickiego 15, Wilanów Office Park, bud. B1 • Tel. +48 22 3300620Romania • RO-023961 Bucharest, Str. Mântuleasa nr. 15A et. 1, Sector 2 • Tel. +40 372 756316Russia • RU-129626 Moscow, Ul. Staroalexejevskaja 5 • Tel. +7 495 5105015Slovakia • SK-83527 Bratislava–Rača, Mudrochova 2 • Tel. +421 2 44635595Sweden • SE-126 30 Hägersten, Västberga Allé 60, Plan D • Tel. +46 8 6801860Turkey • TR-34718 Kadıköy-Istanbul, Koşuyolu Mah. Ismailpaşa Sok. 78 • Tel. +90 216 3455199

    BG BIH BY CH CY D DK E EST ET F GE GR HR I IL KS KSA KWT KZ L LT LV MK NL P PK RB RL SLO SRB TM UA UAE UZAZARM NFIN

    ONCOMPETENCE