This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
IntegraCAD 2011 (for Enterprise, Premium, Suite, Professional, Termo, Duct and Sani program version)
Professional program for designers of heating, cooling,
ventilation, potable water and drainage installations.
IntegraCAD 2011 is a software program intenden for solving all design problems with potable and drainage water pipeline calculation, heating pipelines, radiator selection (for two pipe system and one pipe system), fan coil selection and fan coil pipeline, floor and wall heating and cooling. You can print the calculation results and material lists directly or export them in several xls file format.
Program packages
You can purchase IntegraCAD 2011 in four different packages. Sani, Duct, Termo, Professional, Suite, Premium, Enterprise. The program packages include the same program framework (program interface, CAD, print, database) but a different amount of calculation modules. You can compare the different packages in the table below:
CAD
The CAD moduel can be used to work with technical drawings. You can use drawings in dwg (up to version 2010) and dxf file formats. The program CAD module is completely autonomous and you do not need for any other CAD software to be installed on the computer to work with the drawings. You can create new or edit existing drawings. To find out more follow these links: CAD basics and CAD functions overview
Print
The print module of the program has the following features:
- Standard text editing tools - Edit material lists with capability to add products directly from the program database - Translate the printouts to seeral languages (Albanian, Bulgarian, Bosnian, Chinese (simplified), English, Croatian, Hungarian, Macedonian, Romanian, Russian, Slovenian, Serbian, Turkish.) - Export printouts to xls format - Print with print preview function
Product catalogue
The program has an included products catalogue with technical data, descriptions pictures and article numbers. All products are sorted into groups to allow easyer browsing. The calculation modules use the same technical data as displayed in the catalogue module of the program. You can also use these data to edit material lists in the print module.
New ! - Internet presentation and training
We offer Internet support through a specialised web conferencing system. During the conference the participants can see the presenters screen and follow the session in real time. All users see the same video output (the presenters screen) and can communicate with each other through a live audio connection.
An Internet presentation is the simplest and fastest way to experience the capabilities of the program. Without generating costs and with a minimum time investment, everybody with an interest in the program can get the answers to his/her questions. The presentation will give you a general overview of the software without discussing the fine points. After the presentation phase there will be time for Q&A
and a possibility to explore some questions deeper. Program presentations can be individual or public.
Getting help for a current issue has never been easier. Program users can contact us by phone, e-mail or Skype and we will organize a support session as soon as possible. You can ask general questions (how to start a program function, avoid problems, etc.) or questions related to a current project. In general, the explanations will be made with standard support projects. For bigger issues, you can send us your project and drawing files and we will do our best to help. If the problems cannot be resolved during the support session, we will transfer them to our standard technical support procedure.
Internet training allows for a thorough insight into a part of the program. As a program user you have two options: you can request an individual training or you can join one of the regular public trainings. In the first case you can select the training topic freely but you need to make your training request at least 7 days in advance. In the case of public trainings the topic and date are already set and you need to apply at least 24 hours in advance. Public training dates will be announced on our website www.integracad.com at least two weeks in advance.
System requirements
Note!
Before you install IntegraCAD program close all running programs. If you have Windows XP on your computer please make sure that you have installed at least Service Pack 2 (My Computer / Control Panel / System / Service Pack no.) Compatible Service Pack and dot net framework you can copy and install from the IntegraCAD installation CD (folder Windows): * Service Pack * Windows -> XP -> WindowsXP-KB942288-v3-x86.exe * dot net framework * Windows -> dotnetfx35.exe or if you don't have IntegraCAD installation CD than download components from following link: http://dl.dropbox.com/u/5681482/Windows.zip
IntegraCAD 2011
Computer system
Minimum Suggested
CPU 1,4 GHz Intel® Core™ 2 Duo
RAM 512 MB
(min. for win XP) 2 GB
(min. for win 7)
Viewscreen 19" 21"
Hard disk 400 MB
Operating system
Windows XP (at least SP2), Vista or Win 7 (32/64 bit)
Licence portable licence with USB stick -
Licence time is period of 30; 90 or 365 days. After that time program will stop
working. Licence time you choose when buying program licence.
Program installation from installation CD
Note! All pictures in this help are from english program version and can be different than your IntegraCAD language program version or your IntegraCAD program package (Enterprise, Premium, Suite, Professional, Termo, Duct or Sani)!
Take the CD out of the casing and insert it into your CD-ROM drive. Click the My Computer icon and choose the CD-ROM unit containing the CD Click the name, find IntegraCAD 2011 Setup (language).exe, copy that on your Desktop run it and follow the instructions shown on the screen. Warning! Before you install IntegraCAD program close all running programs. If you have Windows XP on your computer please make sure that you have installed at least Service Pack 2 (My Computer / Control Panel / System / Service Pack no.) Compatible Service Pack and dot net framework you can copy and install from the IntegraCAD installation CD (folder Windows): * Service Pack * Windows -> XP -> WindowsXP-KB942288-v3-x86.exe * dot net framework * Windows -> dotnetfx35.exe or if you don't have IntegraCAD installation CD than download components from following link: http://dl.dropbox.com/u/5681482/Windows.zip
Short description of program installation: 1.) extraction files window (will last for a few seconds) 2.) language selection (select installation language, and press OK button to continue instalation) 3.) welcome window (press Next button to continue instalation) 4.) licence agreement window (press Yes I Accept the terms of the Licence Agreement button, and then press Next button to continue instalation) 5.) User information window (type your name and the name of the company you work for, and then press Next button to continue instalation) 6.) Choose Destination Location window (we recommend to permit the program to install his components to his offered directory in that case just press Next button to continue instalation, if you want to install program to some different directory press Browse button - select another directory, and than press Next button to continue instalation) 7.) Set file Association window (press OK button to continue instalation) 8.) Set program shortcuts window (beside the one that program will automatically add on your Start/Program menu, you may add some other shortcuts, press Next button to continue instalation) 9.) Confirm setup settings window (press Next button to continue instalation) 10.) First setup program will install Redist_pack components (it can take a few minutes) 11.) and then will install IntegraCAD 2011 program (it can take a few minutes) 12.) Setup Complete window (press Finish button to complete program installation)
After program installation try to run IntegaCAD program (check that USB key is inserted into your computer!)
If you start a IntegraCAD program then Step number II. will not be needed! If program (after you run it) show following window
you'll need to register it (see Program registration).
Program registration
This serial number is your private number and it allows you to use the program. Before you start working with IntegraCAD you should contact the program distributor or Impuls ing d.o.o and supply them with exact information on the name of your program, its Version label and the Serial Number (i.e. IntegraCAD 2011 Enterprise, INT50, 4111588392). You'll get an Activation key for starting the program. Run the program and type the activation key in the required spot (delete the zero). If everything was fine you'll se the button OK activated and be able to start working. You need to type the activation key only once; at all other times the program will run without asking this information (in licence time period that you buy 30, 90 or 365 days). After that time period IntegraCAD 2011 version of the program will stop working
Program fundamentals
Starting the program and basic program settings
Note! All pictures in this help are from english program version and can be different than your program language version or your IntegraCAD program package (Enterprise, Premium, Suite, Professional, Termo, Duct or Sani)!
Load the program by pressing Start in the lower left corner of the screen and select Programs -> IntegraCAD 2011 (Language). You can start the program also by double
clicking the program shortcut icon on your desktop .
After the program loads you first need to crate a new project. While you are doing this you will also select the calculations that you need for this project. This is just an initial calculation selection and you can change this afterwards by loading/unloading all calculation modules available in the program. By creating and saving a project the program will make a file with a .int ending. This is your project file and it holds all necessary calculation data like the layout of the building, calculation settigngs, finished calculations etc. To save this data permanently you need to save on a hard disk. If you have installed the program on severral computers you can copy this file and use it to work on other computers with the installed software.
To crate a new project select "New" from the File menu or click the icon in the toolbar. The new project wizard will open in a new window. You can now select the calculations you want to do and proceed or crate a new project template with the calculations you most commonly use. You can crate several project templates for this program.
From the project wizard select "Custom project" and press the "Forward" button. Check the calculations you want to work on this project and click "OK".
Crating a project template:
* Select the custom template and check the calculations you want to be part of the new template. * Click "Save template". * Enter the template name and description and click "Save".
In future projects you can select this new project template form the initial project wizard screen and speed up your calculation selection. You can make several project templates if you like.
Open existing projects
Existing projects can be opened by using the "Open" function from the toolbar or by selecting the same function from the File menu. A new window will open and you need to locate the file on your computer or network (you are looking for a file with the .int extension).
Saving the active project
During work it is possible to save the project to file by using the "Save" function in the
toolbar or the same function from the File menu. A new window will open and you need to give a new file name (or edit the existing file name) and save the file to a disk. If you want to make a copy of the project you can use the "Save as..." function in the File menu. You can always save the project to file from anywhere in the program. We recommend saving the project on a regular basis and also keeping backup files of important projects on other media (network disk, USB disk, CD/DVD ...). This is the best way to insure data integrity and accuracy. To help you with this you can use the integrate Autosave function.
Project settings
After creating the project the program will load the selected calculations and setup some basic program settings. After these preparations the first thing you have to do is to create a new building structure. An empty project as initially created by the program is displyed below:
In the upper part of the screen you can see the main menu and toolbar. They include the most common program functions like loading and saving projects, selecting settings, loading/unloading calculation modules etc. On the left side of the screen you can see the tree controls (Project, CAD, Installations, Catalogue) and everything on the right is the main Workspace. The program has four tree controls, each with a distinctive purpose: The project tree - its purpose is to create, edit and view the building and its parts (floors, flats, rooms). The position on this tree often determines to what part of the building some calculation is reffering (e.g if you are positioned on the first floor in the project tree and want to do a radiator selection, the program will do the selection for all rooms on the first floor.)
The CAD tree - its purpose is to view and change different settings related to the CAD module. This tree is generally active only when you disply the CAD module on your workspace. You can look at object settings selected inside the CAD drawing surface or look at a list of pipeline drawing connection errors and warnings. You can use this list to quickly jump from one problem to another which is very usefull in a large project drawing. The installation tree - its purpose is to create, edit and view the building pipeline installations (pipelines). This is the place to add new instalations, floor entry points and manifolds. The installation tree is connected to the project tree (e.g. the program will know on which floor a floor entry point is set) but it is not a copy of its structure. You have to define the structure separately from the building structure. You can for example have risers going through each floor but having only floor entry points at every second floor. In this event the number of floor entry points on one riser does not correspond to the number of floors it passes through. The catalogue tree - its purpose is to enable you a look on the products included in the program database in a hierarchical way for easyer product browsing. You can search the products while in the Catalogue module or use it to create CAD drawings in the CAD module or insert products in lists of material in the print module.
The workspace is right of the tree controls and covers the majority of the screen. Most actions happen in it like calculations, print preparation etc. The workspace consists from five interconecting parts: Info, Calculation, CAD, Print and Catalogue. You can switch between these modules simply by clicking on the tab names. Info is the part that is active when you start a new project and its main purpose is to display information about parts of the project. Calculation is the part that includes all calculation modules that can be activated in the program. To move between the different calculations you have to click on the tabs with the calculation names (top of the workspace). To move inside a particular calculation you have to click on the vertical tabs with the calculation part names located in between the tree controls and the workspace. CAD is the part where you can create and edit drawings. This module is compatible with the drawing formats dwg and dxf and includes most common drawing functions found in specialized CAD drawing software programs. To bind drawings to a project you have to make a connection between the drawing file and the floor it represents. Print is the part where you can create and edit different representations of the calculated data. The print module consists of calculation results and lists of material (Bills of Material). Catalogue is the part where you can view and browse products from the program database. You select different products using the Catalogue tree control and the product data is displayed in the Catalogue module on the workspace.
Below the workspace is an information bar where the program displays messages to the user, mostly about the progress of started functions like "Calculation finished" or "Project loaded". Most actions that take a longer time to execute will display progress information in the information bar.
Creating a building with the project tree
* Click on New project in the project tree on the left. * Right click on it -> a drop down list with several options will appear -> select Floor. * Now that you have created a new floor, by rightclicking on it you can create appartments and rooms. You can also create rooms inside of appartments. Once you are done creating floors and appartments you can rightclick on one and select a new room from the preloaded list of common rooms. Grouping rooms inside appartments is only made for the purpose of creating a more accurate representation of the building. Other than that there are no restrictions or benefits connected to it. Copying floors, appartments and rooms: Select the entity you whish to copy in the project tree -> rightclick on it and select "Copy" from the drop down list -> select the postition where you want to copy the entity, right click and choose "Paste". To be able to use this function correctly you usually need to go one level up e.g. to paste a room you need to select an appartment or floor, to paste an appartment you need to select a floor, to paste a floor you need to select the project . When you copy an appartment you automatically also copy all the rooms in it. When you copy a room, you also copy all the calculation data connected to it like radiator selection, underfloor heating calculations etc. Deleteing floors, appartments and rooms: Set the pointer on the entity you want to erase from the project tree, right click on it and choose "Delete" from the drop down menu. Changing names of floors, appartments and rooms: Select the entity for the name change in the project tree and press F2 on the keyboard or click one more time on it -> the name will turn blue and you can change it .
Use the described functions to construct you building. You can change all parts of the building (floors, appartments, rooms) anytime you want. WARNING: If you delete a part of the building by accident there is no undo function to bring it back. Save your project often to avoid loosing you work in this way.
Changing the tree position of floors, appartments and rooms
* Select an entity in the tree control.
* Using the arrow buttons up and down change the current entity position until it reaches the desired position.
Main menu
The Main menu is used to manage a project; the appearance and position of windows, main files and the help system. It is divided into the following sub menus: File, Edit, View, Print, Help.
File - used to manage basic project functions. New - creates a new project, Open - opens an existing project, Close - closes the active project, Save - saves the active project, Save as ... - saves the project named as, Print - prints project, Print preview, Printer settings - sets parameters of the printer; these options are followed by path and names of the last four projects used. The option Exit is used to exit the IntegraCAD program.
Edit - this menu contains standard data editing tools - Undo - move previous command, Redo - returns to previous command, Cut - cuts data (makes a copy but doesn't keep the original); Copy - for copying data (makes a copy and keeps the original; Paste - pastes cut or copied data on a chosen place, Settings - adjust program settings and CAD module in IntegraCAD program, Admin - tool for radiator or room importing, if the same does not exist in the IntegraCAD program.
View - contains settings which apply to the whole program and all the projects. Tool bar - used to turn on/off all tool bars in the program (main, for print...) or some for program tree (project, installation, catalogue). Function "Reset toolbal position" - will cancel all current settings, and return it to the standard form in which the program is delivered. Option - "Status bar" - can turn on or turn off status bar window (at the bottom of the IntegraCAD program window) - that displays information about last program activities.
Print - Menu where you can turn on / off some prints. There are two possible ways: 1.) direct from the menu (shorter display)
2.) or by "Print settings" button (in that menu) - graphically displays individual prints
Help - used to obtain basic information on IntegraCAD program and advice on using it. Help content - opens a new window with the program's help file displayed. About - build number (RC number) - e.g. on picture RC34, and some basic informations about authors.
Calculation - here you can turn on / off some calculations.
Info window
On project level:
Here you can enter some basic datas about project, they are not required, but can be helpful in further work. Insert datas can also be printed.
* Enter object name and project number. * Select date from calendar * In field "Note" you can enter some text for project description . * Enter data about designer and investor.
On floor level:
Here you can define some basic geometry floor attribute (ceiling height, room height, height above ground), path where the drawing file is stored on the disk, drawing measure, label text height in the drawing. IntegraCAD 2011 works with standard .dwg drawings, and it's compatible with AutoCAD drawing files up to version AutoCAD 2010.
Under basic geometry attributes there are some heating and cooling calculation datas for every room on floor.
* Select floor (on project tree). * On left you can enter floor dimensions, like ceiling height, room height, height above ground. * In "Drawing settings" part you can set DWG file path.
* On default settings press button (DWG file path) and select drawing (drawing path), that you want to join to the floor. Drawing must be in .dwg or in .dxf format.
We recommend that the *.int and *.dwg file record in the same directory.
* Press button on default settings (Measure) to define measure, measure units and text style settings.
Here you can also set the some element labels that you will later used in the calculations. Default labels are: F - floor label; A - apartment label; R - room label. Also some tags can be customized according to the building, according to the floor or to the flat. Program accepted new settings by pressing a Set button.
In table below you can see some datas related with rooms in project.
Label room label
Room room name
A (m2) room name
ti (°C) internal temperature in (°C)
Qn (W) heat gains in (W)
Qinst (W) installed heating capacity in (W)
Qres (W) remaining heat quantity (W)
Qi(two) (W) total installed heat capacity with two pipe system in (W)
Qi(one) (W)
total installed heat capacity with one pipe system in (W)
Qi(flh) (W) total installed heat capacity with floor heating /cooling in (W)
Qi(wall) (W)
total installed heat capacity with wall heating /cooling in (W)
Qi(fc) (W); total installed heat capacity with fancoil /cooling heating in
(W)
Product catalogue
You can activate the product catalogue by clicking the Catalogue tab in the Tree view
and also on the main workspace (you need to click both). .
Within the catalogue tree view the products are sorted by :
* group (pipe, fittings, sink points, manifolds, radiators...)
* subgroups (FUSIOTHERM-Pipe SDR 6 (PN 20) ...)
* products (Fusiotherm SDR 6 16 x 2,7 , Fusiotherm SDR 6 20 x 3,4 , ... )
If you want to get more information about an item just click on it.
On the workspace you will get more detailed data (most details are for products):
* Manufacturer logo
* Product picture
* Article number
* Short and long product description
* Technical data
Short description of abbreviations in
calculations
HEAT LOAD ACC. TO EN 12831
DEFAULT SETTINGS
Heat loss
outside project
temperatue (°C) Norm. outside temperature according to EN12831
Annual mean
external
temeprature (°C)
Mead value of the external temeprature during the year
Shielding class
No shielding (buildings in windy areas, high rise buildins in city centers);
Moderate shielding (buildings in the country with trees or other buildins
around them, suburbs); Heavy shielding (average height buildins in city
centers, buildings in forrests)
Building type Single family dwelling; Other dwellings and buildings
Degree of air-
tightness
Degree of air-tightness of the building envelope (quality of window seal)
can be ;High (high quality sealed windows and doors); Madium (double
glaze windows, normal seal); Low (single glaze windows, no sealant)
Air exchange rate
n50
for the whole building resulting from a pressure difference of 50 Pa
between the inside and the outside is determined according to the degree
of air-tighness and the building type. The program will suggest the range
for the values to be entered (for example between 4 and 10 for a single
family dwelling with a medium degree of air-tightness).
Construction
can be: Low building mass (suspended ceilings and raised floors and ligh
walls); Madium building mass (cencrete floor and ceilings and light
walls); High building mass (concrete floors and ceilings combined with
concrete or brick walls)
Underground
water depth (m)
The depth of ground water can be set to below or above one meter. If the
value is set below one meter, the transmission heat loss towards the
ground will be increased (Gw, the ground water correction factor will be
increased from 1 to 1.15).
Volume of the
building (m3) Total building volume
V ex (m3/h) Exhaust air flow rate the whole building
V su (m3/h) Supply flow rate for the whole building
parametar B' for building
P (m) Floor perimeter
Ag (m2) Floor surface
B'
Parametar B' for all rooms without external walls separating the heated
space under consideration from the external enviroment, and for all rooms
with well insulated floor
Recalculate heat
losses
The "Recalculate heat losses" button will make a complete heat load
calculation using the values set in the calculation defaults. You can use
this for example to recalculate the heat load using a different design
external temperature
Transfer heat loss
to equipment
selection
The "Transfer heat loss to equipment selection" will overwrite and heat
loss values in the equipment selection calculation modules (radiator
selection, underfloor heating ...). You can use this before the initial
equipment selection but also when you made some changes to the heat
load calculation and want to see the effects on the already selected
equipment.
CALCULATION
Input room data
A/a (m2/m) Room surface or length
b (m) Room width
c (m) Room height
h (m) Floor height from ground
V (m3) Room volume
O (m2) Superficial area of room
Theta su, i (°C) Temperature of supply air for mechanical ventilation
V su,i (m3/h) Supply air flow rate for mechanical ventilation
Nr. of openings Number of exterior openings
e i Shielding coefficient
n min (1/h) Minimal air exchange rate in one hour
f vi Temperature reduction factor (depending on internal room temperature,
supply air temeprature and external design temperature)
Theta int,i Internal roo mtemperature
T (m) Depth of ground water
Gw Ground water correction factor
fg1 Correction factor taking into account the influence of annual variation of
external temperature.
fh,i Correction factor for room height (rooms between 5 m and 15 m heigh)
f RH Correction factor for heating-up
Calculation results
Theta e (°C) External design temperature (°C)
Phi V, inf (W) Infiltration ventilation losses
Phi V, min (W) Hygiene air flow ventilation losses
Phi V, mech, inf
(W) Mechanical ventilation losses for building
Phi V, su (W) Room supply air mechanical ventilation losses
Phi V, mech (W) Total mechanical ventilation losses
Phi T, i (W) Transmission heat loss
Phi V, i (W) Ventilation heat loss
Phi RH (W) Heating-up capacity heat loss
Phi (W) Heat load
Phi/A (W/m2) Heat load per square meter
Phi/V (W/m3) Heat load per cubic meter
Table
Lab. Building element label
Surface to Surface type on the other side of the building element (exterior, non-
heated room, ground etc.)
OR Orientation of building element
Nr. Number of equal elements (equal by dimmension, U coeff., position etc.)
LEN (m) Length of building element in meters
H/W (m) Height of width of building element in meters
column for wall (pipes) connection in the tichelmann system. This function
you'll can use if you have at least 2 walls written in the table along with
theirs lengths of x-zones. Then you can simply with drag mouse function
connect that pipes in the tichelmann system. Than in this column will be
printed label of tichelmann system and the required length of pipe (needed
for that connection)./td>
Lbl
Label that is associated with the U coefficient calculation. If you already
calculated U coefficient value in coefficient calculation, that just in this
column type the same label (as there), and program will automatically pull
that value in this Wall calculation part and place it in "U (W/m2)" column.
Label wall label (made automatically by program) (WL + number that program
automatically assigns). Label can be changed.
V/M manifold that is connected with loop.
U(W/m2)
Thermal transmittance of building element. If you already calculated U
coefficient value in coefficient calculation, that just in column "Lbl" type
the same label (as there), and program will automatically pull that value
here.
Out temp. outdoor temperature (temperature behind the wall)
Lenght (m) wall lenght
Height (m) wall height
A (m2) wall surface that you want to fill with loop
X-zone lenght of x-zone
T (mm) pipe step - value can be changed by double-clicking on the column.
tw (mm) (°C) wall temperature
Δt (°C) temperature difference between supply and return water
l (m) loop length (that goes on that wall)
Qins (W) installed cooling capacity
Qtot (W) total wall cooling capacity
q (W/m2) amount of cooling that loop gives
m (kg/h) mass flow
w (m/s) needed water flow
Δp (kPa) pressure droop
Valve. pos. manifold balance valve position
FAN COIL SELECTION
DEFAULT SETTINGS
Default settings
FC2-1 fan-coil installation
(two pipe)
short description of selected fan-coil in installation (FC2 - for two
pipe system or FC4 - for four pipe system)
Fan-coil group
select fan coil group. To be able to choose the two-pipe fan coil
systems on branch tree, select: Fan coil installation (two pipe); If
you want to work with four pipe fan coil, on branch tree, select:
Fan coil installation (four pipe)
Description short description of selected fan coil group
Num. of connections informative field where you can see the number of selected fan-
coil connections.
Velocity fan-coil velocity selection. Number list depends of selected fan-
coil model.
Maxsimum length maxsimum length selection. Number list depends of selected fan-
coil model.
Heating settings
Supply water temperature
(°C)
enter supply water temperature for heating. Program will offer
some standard supply temperature, but data can be changed.
Δt (°C)
temperature difference between supply and return water for
heating Program will offer some standard temperature value, but
you can change it.
Cooling settings
Supply water temperature
(°C)
enter supply water temperature for cooling. Program will offer
some standard supply temperature, but data can be changed.
Δt (°C)
temperature difference between supply and return water for
cooling Program will offer some standard temperature value, but
you can change it.
Humidity (%) humidity percentage in the room
Recalculate installation pressing this button program will recalculate a complete fan coil
installation according to some new set values.
CALCULATION
Options
Calculate all
Clicking on this button program will delete existing fan coil units
and replace them with some new according to some new
calculation settings. (e.g. calculation according to water
temperature or according to water flow temperature)
Add
Pressing this button a new window will appear Then program will
automatically add one fan coil in the row in the table where you
are positioned.
Delete pressing this button program will delete currently selected fan coil
Delete all pressing this button program will erase all existing fan coil units.
Calculation accoding to
water temperature
Calculation will be made by water temperature. To make
calculation accoding to water temperature (after you mark
Calculation accoding to water temperature radio button) press
"Calculate All" button.
Calculation accoding to
water flow temperature
Calculation will be made by water flow temperature. To make
calculation accoding to water flow temperature (after you mark
Calculation accoding to water flow temperature radio button) press
"Calculate All" button.
Calculation for:
Project/Floor/Room Short description of the calculation position
Table 1
Label fan coil name
Qh (W) cooling capacity
Qs (W) sensory cooling capacity
Δph (kPa) cooling pressure drop
Qg (w) heat capacity
Δpg (kPa) heating pressure drop
Noise (dBa) fan coil noise - depends on the selected fan coil velocity
Length (mm) fan coil length
Width (mm) fan coil width
Heigth (mm) fan coil heigth
Table 2
Room room name for which we do calculation
According to: calculation selection according to heating or cooling
ti inner room temperature
Qn (W) required capacity
sum Qi (W) installed capacity sum
Qi (W) installed capacity
Speed fan coil speed
V/M label for floor entry point / Riser
Label fan coil label (FC-2 two pipe fan coil or FC4 four pipe fan coil)
Model fan coil model - associated with the column "Label" from the
previous table 1
m (kg/h) Mass flow
Δp (kPa) Pressure drop
Z (kPa) additional pressure drop
Δt (°C) Flow and return temperature difference
Noise (dBa) noise at the selected speed
HEATING PIPELINE CALCULATION
DEFAULT SETTINGS
Warning!
Warning! Basic settings are associated with the entrance of heating.
You must choose input installation of heating on a tree branch.
Message that is displayed on top of the window after you open this
calculation if you did not create heating installation on the branch tree.
It's like a first step that must be done otherwise this calculation will not
be able to use.
After you create it new field will appear "Pipe group".
Pipe group choose default pipe from database. Press button (...), choose pipe group
and choose default pipe
Supply water temp.
(°C) enter supply water temperature
Return water temp.
(°C) enter return water temperature
Physical characteristic of water
Mean water temp.
(°C)
medium water temperature - program will give this value about
physical characteristics of water
Water temp.
difference (°C)
Water temperature difference - program will give this value about
physical characteristics of water
Water density
(kg/m3)
Water density - program will give this value about physical
characteristics of water
Water viscosity
(m2/s*10^6)
Water viscosity - program will give this value about physical
characteristics of water
Spec. water heat
(kJ/kgK)
Specific water heat - program will give this value about physical
characteristics of water
Optimized calculation
Pipe dimensioning
according to max.
water flow velocity
Pipe dimensioning according to maximum water flow velocity. check
box and enter values in the next to fileds Water flow velocity in vert.
pipeline (m/s) and Water flow velocity in hor. pipeline (m/s). If this
check box is unchecked Pipe dimensioning according to max. water
flow velocity will not be possible.
Water flow velocity
in vert. pipeline
(m/s)
Water flow velocity in vertical pipeline
Water flow velocity
in hor. pipeline (m/s) Water flow velocity in horizontal pipeline
According to const.
pressure drop (Pa/m)
Pipe dimensioning according to constant pressure drop. check box and
enter value. If this check box is unchecked Pipe dimensioning
according to constant pressure drop will not be possible.
Balancing valve
Vertical select balancing valve for vertical branch calculation
Horizontal select balancing valve for horizontal branch calculation
Construct pipeline
After you define branches, click "Construct pipeline". Branches will be
automatically sorted and you can review them on a branch tree
(clicking on the desired branch) or in tables (clicking in any branch
field in the table).
Assign fittings
For selected heating installation (marked on the branch tree) program
passes through all sections and sets fittings. This command adds only
the reduction, t pieces and couplings. All previously installed fittings
will be deleted.
VERTICAL
Table 1
R*L+Z (kPa) Total pressure drop on branch
m (kg/h) mass flow
Construct pipeline
After you define branches, click "Construct pipeline". Branches will be
automatically sorted and you can review them on a branch tree
(clicking on the desired branch) or in tables (clicking in any branch
field in the table).
Assign fittings
For selected heating installation (marked on the branch tree) program
passes through all sections and sets fittings. This command adds only
the reduction, t pieces and couplings. All previously installed fittings
will be deleted.
Copy flow or return
sections
If you already made flow sections, than (pressing this button) program
can copy in this table the same flow sections as return sections.
Table 2
Type
sections type (flow or return sections). Red arrows is mark for flow
section, blue arrows is mark for return section. Program first begin to
enter flow sections, and then continues with return sections. You can
replace this two sections types on simple way if you do double click
with left mouse button in this column.
From Starting section point. Program will automatically put endpoint of
section in column "To" (Note: first section must start with number 1).
To
section endpoint. After you finish with flow section input in table, you
can do return sections. In next table line for a starting point tipe again
number 1, or use "Copy flow or return sections" button.
Device Double-click in column field "Device" and select floor entry that is
connected to section endpoint.
Q (W) section capacity
m (kg/h) mass flow
V (l/s) volume flow
L (m) section lenght
ζ
Minor loss coefficient. Double-click in this column and you can define
types and number of local pressure drop (T-pieces; elbows..). Program
will calculate total coefficient of local pressure drops based on selected
types and number of elements. If you do not want to choose fitting
products from the database you can manually enter the "Zeta" value.
Value will be taken into account later in the calculations.
DN
exterior pipe diameter. if you want to change some pipe than here type
some other exterior pipe diameter (DN) (e.g. 20, 25, 30,...). Program
will select first pipe (from program datebase) whith that DN.
Pipe
Pipe selection: program select pipe according to heat flow, but you can
for every section select some other pipe. For selection do double-click
in column.
t (°C) Section water temperature (selected on default settings). Value can be
changed.
w (m/s) section flow - program calculate this value
R (kPa/m) pressure drop in section due to local pressure drop
R*L (kPa) line pressure drop in section
Z (kPa) pad tlaka zbog lokalnih otpora
R*L+Z (kPa) maksimum pressure drop
kv coefficient flow on valve
xb adjustment valve position
HORIZONTAL
Construct pipeline
After you define branches, click "Construct pipeline". Branches will be
automatically sorted and you can review them on a branch tree
(clicking on the desired branch) or in tables (clicking in any branch
field in the table).
Assign fittings
For selected heating installation (marked on the branch tree) program
passes through all sections and sets fittings. This command adds only
the reduction, t pieces and couplings. All previously installed fittings
will be deleted.
Copy flow or return
sections
If you already made flow sections, than (pressing this button) program
can copy in this table the same flow sections as return sections.
Table 2
Type
sections type (flow or return sections). Red arrows is mark for flow
section, blue arrows is mark for return section. Program first begin to
enter flow sections, and then continues with return sections. You can
replace this two sections types on simple way if you do double click
with left mouse button in this column.
From Starting section point. Program will automatically put endpoint of
section in column "To" (Note: first section must start with number 1).
To
section endpoint. After you finish with flow section input in table, you
can do return sections. In next table line for a starting point tipe again
number 1, or use "Copy flow or return sections" button.
Device Double-click in column field "Device" and select floor entry that is
connected to section endpoint.
Q (W) section capacity
m (kg/h) mass flow
V (l/s) volume flow
L (m) section lenght
ζ
Minor loss coefficient. Double-click in this column and you can define
types and number of local pressure drop (T-pieces; elbows..). Program
will calculate total coefficient of local pressure drops based on selected
types and number of elements. If you do not want to choose fitting
products from the database you can manually enter the "Zeta" value.
Value will be taken into account later in the calculations.
DN
exterior pipe diameter. if you want to change some pipe than here type
some other exterior pipe diameter (DN) (e.g. 20, 25, 30,...). Program
will select first pipe (from program datebase) whith that DN.
Pipe
Pipe selection: program select pipe according to heat flow, but you can
for every section select some other pipe. For selection do double-click
in column.
t (°C) Section water temperature (selected on default settings). Value can be
changed.
w (m/s) section flow - program calculate this value
R (kPa/m) pressure drop in section due to local pressure drop
R*L (kPa) line pressure drop in section
Z (kPa) pad tlaka zbog lokalnih otpora
R*L+Z (kPa) maksimum pressure drop
kv coefficient flow on valve
xb adjustment valve position
FAN COIL PIPELINE CALCULATION
DEFAULT SETTINGS
Warning!
Warning! Basic settings are associated with the entrance of fan-coil.
You must choose input installation of fan-coil on a tree branch.
Message that is displayed on top of the window after you open this
calculation if you did not create heating installation on the branch tree.
It's like a first step that must be done otherwise this calculation will not
be able to use. After you create it new field will appear "Pipe group".
Pipe group choose default pipe from database. Press button (...), choose pipe group
and choose default pipe
Calculation mode
choose one of two calculation mode typs (heating or cooling). Program
will in further calculation take into account the temperature of the
selected system and do calculation for fan coil (heating or cooling)
capacity.
Recalculate
Press this button if you change calculation mode (e.g. heating to
cooling), so that program can accept new regime, and do calculation
according to that selection.
Supply water temp
(°C) enter supply water temperature
Return water temp
(°C) enter return water temperature
Physical characteristic of water
Mean water temp.
(°C)
medium water temperature - program will give this value about
physical characteristics of water
Water temp.
difference (°C)
Water temperature difference - program will give this value about
physical characteristics of water
Water density
(kg/m3)
Water density - program will give this value about physical
characteristics of water
Water viscosity
(m2/s*10^6)
Water viscosity - program will give this value about physical
characteristics of water
Spec. water heat
(kJ/kgK)
Specific water heat - program will give this value about physical
characteristics of water
Optimized calculation
Pipe dimensioning
according to max.
water flow velocity
Pipe dimensioning according to maximum water flow velocity. check
box and enter values in the next to fileds Water flow velocity in vert.
pipeline (m/s) and Water flow velocity in hor. pipeline (m/s). If this
check box is unchecked Pipe dimensioning according to max. water
flow velocity will not be possible.
Water flow velocity
in vert. pipeline
(m/s)
Water flow velocity in vertical pipeline
Water flow velocity
in hor. pipeline (m/s) Water flow velocity in horizontal pipeline
According to const.
pressure drop (Pa/m)
Pipe dimensioning according to constant pressure drop. check box and
enter value. If this check box is unchecked Pipe dimensioning
according to constant pressure drop will not be possible.
Balancing valve
Vertical select balancing valve for vertical branch calculation
Horizontal select balancing valve for horizontal branch calculation
Construct pipeline
After you define branches, click "Construct pipeline". Branches will be
automatically sorted and you can review them on a branch tree
(clicking on the desired branch) or in tables (clicking in any branch
field in the table).
Assign fittings
For selected heating installation (marked on the branch tree) program
passes through all sections and sets fittings. This command adds only
the reduction, t pieces and couplings. All previously installed fittings
will be deleted.
VERTICAL
Table 1
R*L+Z (kPa) Total pressure drop on branch
m (kg/h) mass flow
Construct pipeline
After you define branches, click "Construct pipeline". Branches will be
automatically sorted and you can review them on a branch tree
(clicking on the desired branch) or in tables (clicking in any branch
field in the table).
Assign fittings
For selected heating installation (marked on the branch tree) program
passes through all sections and sets fittings. This command adds only
the reduction, t pieces and couplings. All previously installed fittings
will be deleted.
Copy flow or return
sections
If you already made flow sections, than (pressing this button) program
can copy in this table the same flow sections as return sections.
Table 2
Type
sections type (flow or return sections). Red arrows is mark for flow
section, blue arrows is mark for return section. Program first begin to
enter flow sections, and then continues with return sections. You can
replace this two sections types on simple way if you do double click
with left mouse button in this column.
From Starting section point. Program will automatically put endpoint of
section in column "To" (Note: first section must start with number 1).
To
section endpoint. After you finish with flow section input in table, you
can do return sections. In next table line for a starting point tipe again
number 1, or use "Copy flow or return sections" button.
Device Double-click in column field "Device" and select floor entry that is
connected to section endpoint.
Q (W) section capacity
m (kg/h) mass flow
V (l/s) volume flow
L (m) section lenght
ζ
Minor loss coefficient. Double-click in this column and you can define
types and number of local pressure drop (T-pieces; elbows..). Program
will calculate total coefficient of local pressure drops based on selected
types and number of elements. If you do not want to choose fitting
products from the database you can manually enter the "Zeta" value.
Value will be taken into account later in the calculations.
DN
exterior pipe diameter. if you want to change some pipe than here type
some other exterior pipe diameter (DN) (e.g. 20, 25, 30,...). Program
will select first pipe (from program datebase) whith that DN.
Pipe
Pipe selection: program select pipe according to heat flow, but you can
for every section select some other pipe. For selection do double-click
in column.
t (°C) Section water temperature (selected on default settings). Value can be
changed.
w (m/s) section flow - program calculate this value
R (kPa/m) pressure drop in section due to local pressure drop
R*L (kPa) line pressure drop in section
Z (kPa) pad tlaka zbog lokalnih otpora
R*L+Z (kPa) maksimum pressure drop
kv coefficient flow on valve
xb adjustment valve position
HORIZONTAL
Construct pipeline
After you define branches, click "Construct pipeline". Branches will be
automatically sorted and you can review them on a branch tree
(clicking on the desired branch) or in tables (clicking in any branch
field in the table).
Assign fittings
For selected heating installation (marked on the branch tree) program
passes through all sections and sets fittings. This command adds only
the reduction, t pieces and couplings. All previously installed fittings
will be deleted.
Copy flow or return
sections
If you already made flow sections, than (pressing this button) program
can copy in this table the same flow sections as return sections.
Table 2
Type
sections type (flow or return sections). Red arrows is mark for flow
section, blue arrows is mark for return section. Program first begin to
enter flow sections, and then continues with return sections. You can
replace this two sections types on simple way if you do double click
with left mouse button in this column.
From Starting section point. Program will automatically put endpoint of
section in column "To" (Note: first section must start with number 1).
To
section endpoint. After you finish with flow section input in table, you
can do return sections. In next table line for a starting point tipe again
number 1, or use "Copy flow or return sections" button.
Device Double-click in column field "Device" and select floor entry that is
connected to section endpoint.
Q (W) section capacity
m (kg/h) mass flow
V (l/s) volume flow
L (m) section lenght
ζ
Minor loss coefficient. Double-click in this column and you can define
types and number of local pressure drop (T-pieces; elbows..). Program
will calculate total coefficient of local pressure drops based on selected
types and number of elements. If you do not want to choose fitting
products from the database you can manually enter the "Zeta" value.
Value will be taken into account later in the calculations.
DN
exterior pipe diameter. if you want to change some pipe than here type
some other exterior pipe diameter (DN) (e.g. 20, 25, 30,...). Program
will select first pipe (from program datebase) whith that DN.
Pipe
Pipe selection: program select pipe according to heat flow, but you can
for every section select some other pipe. For selection do double-click
in column.
t (°C) Section water temperature (selected on default settings). Value can be
changed.
w (m/s) section flow - program calculate this value
R (kPa/m) pressure drop in section due to local pressure drop
R*L (kPa) line pressure drop in section
Z (kPa) pad tlaka zbog lokalnih otpora
R*L+Z (kPa) maksimum pressure drop
Valve fan coil valve
kv coefficient flow on valve
xb adjustment valve position
PORTABLE WATER PIPELINE CALCULATION
DEFAULT SETTINGS
Warning!
Warning! Basic settings are associated with the entrance of water
installations. You must choose input installation of water on a tree
branch.
Message that is displayed on top of the window after you open this
calculation if you did not create portable water installation on the
branch tree. It's like a first step that must be done otherwise this
calculation will not be able to use. After you create it new field will
appear "Building type"
Building type
select building type (according to DIN 1988). Residential building,
Commercial building, Hotel, Department store, Hospital, School ...
When building type is defined program will scale assumed water flow
to require water flow.
Cold water temp.
(°C) type cold water temperature in system.
Hot water temp. (°C) type hot water temperature in system.
Cold water pipe (...) press (...) button and select pipe group and default cold water pipe.
Hot water pipe (...) press (...) button and select pipe group and default hot water pipe.
Armatures on
installation
In table field "Sink point" select armature. In the table, you can define
the entire set of armature, which is used in system. Depends on given
armature program will calculate total water flow for the system.
Required water flow depends on total water flow and type of the
building will be calculated. For the permanent water flow in system,
(water flow that last more then 15 minutes) enter the value.
Manufacturer gives relevant values for the watermeter and filter. These
values are maximum water flow through watermeter and filter, and
pressure drop for those devices. If you do this calculation from CAD
than you don't need to select armatures here because program will take
the one from the drawing and input them in the table.
SumVr (l/s) assumed water flow through some armature.
Vs (l/s) required water flow through some armature for selected building type.
Vp (l/s) permanent water flow (last's more than 15 minutes) - e.g. flow for pipes
for garden watering.
Min. pressure ent.
point (kPa) Minimal pressure on entry point of the building
Constant water velocity
Pipe dimensioning
according to max.
water flow velocity
Pipe dimensioning according to maximum water flow velocity. Select
window (if you want to do dimensioning according to maximum water
flow velocity) and type maximum water flow velocity in vertical and
horizontal pipeline.
Water flow velocity
in vert. pipeline (m/s)
Type water flow velocity in vertical pipeline. This field is visible only
if field "Pipe dimensioning according to max. water flow velocity" is
checked.
Water flow velocity
in hor. pipeline (m/s)
Type water flow velocity in horizontal pipeline. This field is visible
only if field "Pipe dimensioning according to max. water flow velocity"
is checked.
Watermeter
Vgv (l/s) type maximum water flow through the watermeter.
ΔPgw (kPa) type pressure drop on watermeter.
Filter
Vgf (l/s) type maximum water flow through the filter.
ΔPgf (kPa) type pressure drop on filter.
Quick calculation
Inner diameter for
connection pipe used
for calculation
information field that shows inner diameter of selected connection pipe.
info field shows selected selected connection pipe
VERTICAL
Table 1
hgeo (m) geodetic height difference
ΔPgeo (kPa) pressure drop for geodetic difference
ΔPwz (kPa) watermeter pressure drop
ΔPfil (kPa) filter pressure drop
ΔPeh (kPa) pressure drop on water softening device
ΔPdos (kPa) pressure drop on dosing equipement
ΔPte (kPa) pressure drop on water heating device
ΔPap (kPa) pressure drop on other devices
ΔPminFL (kPa) minimal hydraulic pressure
ΔPst (kPa) pressure drop in separate sections
Z (kPa) local pressure drop
SumΔP (kPa) pressure drop on branch
Construct pipeline
After you define branches, click "Construct pipeline". Branches will be
automatically sorted and you can review them on a branch tree
(clicking on the desired branch) or in tables (clicking in any branch
field in the table).
Assign fittings
For selected heating installation (marked on the branch tree) program
passes through all sections and sets fittings. This command adds only
the reduction, t pieces and couplings. All previously installed fittings
will be deleted.
Table 2
Type
sections type (flow or return sections). Red arrows is mark for flow
section, blue arrows is mark for return section. Program first begin to
enter flow sections, and then continues with return sections. You can
replace this two sections types on simple way if you do double click
with left mouse button in this column.
From Starting section point. Program will automatically put endpoint of
section in column "To" (Note: first section must start with number 1).
To
section endpoint. After you finish with flow section input in table, you
can do return sections. In next table line for a starting point tipe again
number 1, or use "Copy flow or return sections" button.
L (m) section lenght
φ minor loss coefficient.
Device
Double-click in column field "Device" and select floor entry that is
connected to section endpoint. (here you connects floor to vertical
pipeline section. Duble click on the cell and choose floor entry for the
pipeline section.)
Vri (l/s) total flow
DN inner pipe diameter
Pipe pipe dimension
Vs (l/s) calculation flow
t (°C) water temperature
w (m/s) water velocity
R (kPa/m) pressure drop per meter
R*L (kPa) pressure drop in pipes caused by fiction
Z (kPa) pressure drop caused by local resistance
R*L+Z (kPa) total pressure drop in section
HORIZONTAL
Construct pipeline
After you define branches, click "Construct pipeline". Branches will be
automatically sorted and you can review them on a branch tree
(clicking on the desired branch) or in tables (clicking in any branch
field in the table).
Assign fittings
For selected heating installation (marked on the branch tree) program
passes through all sections and sets fittings. This command adds only
the reduction, t pieces and couplings. All previously installed fittings
will be deleted.
Table
Type
sections type (flow or return sections). Red arrows is mark for flow
section, blue arrows is mark for return section. Program first begin to
enter flow sections, and then continues with return sections. You can
replace this two sections types on simple way if you do double click
with left mouse button in this column.
From Starting section point. Program will automatically put endpoint of
section in column "To" (Note: first section must start with number 1).
To
section endpoint. After you finish with flow section input in table, you
can do return sections. In next table line for a starting point tipe again
number 1, or use "Copy flow or return sections" button.
L (m) section lenght
φ minor loss coefficient.
Device
Double-click in column field "Device" and select floor entry that is
connected to section endpoint. (here you connects floor to vertical
pipeline section. Duble click on the cell and choose floor entry for the
pipeline section.)
Vri (l/s) total flow
DN inner pipe diameter
Pipe pipe dimension
Vs (l/s) calculation flow
t (°C) water temperature
w (m/s) water velocity
R (kPa/m) pressure drop per meter
R*L (kPa) pressure drop in pipes caused by fiction
Z (kPa) pressure drop caused by local resistance
R*L+Z (kPa) total pressure drop in section
DRAINAGE WATER PIPELINE CALCULATION
DEFAULT SETTINGS
Warning!
Warning! Basic settings are associated with the entrance of drainage. You
must choose input installation of drainage on a tree branch.
Message that is displayed on top of the window after you open this calculation
if you did not create drainage installation on the branch tree. It's like a first
step that must be done otherwise this calculation will not be able to use. After
you create it new field will appear "Building type".
Building type select building type (according to standard). Family building, Hospital,
school, Industrial building ...
SumAws water flow sum for drainage points
Pipe default pipe for drainage calculation. Press (...) button to select default pipe.
qs (l/s) Total flow of building drainage. Depends on the object type and water flow
sum for drainage points.
Gradient Starting pipe decline set with each new pipe section insertion.
Optimized
pipe DN
calculation
if this button is checked program will do calculation according to selected
pipe inner diameter
Armatures on
installation
In table field "Sink point" select armature. In the table, you can define the
entire set of armature, which is used in system. Depends on given armature
program will calculate total water flow for the system. Required water flow
depends on total water flow and type of the building will be calculated. For
the permanent water flow in system, (water flow that last more then 15
minutes) enter the value. Manufacturer gives relevant values for the
watermeter and filter. These values are maximum water flow through
watermeter and filter, and pressure drop for those devices. If you do this
calculation from CAD than you don't need to select armatures here because
program will take the one from the drawing and input them in the table.
Transfer
armatures
pressing this button you can transfer some armatures that you used in portable
water calculation.
VERTICAL
Construct
pipeline
after you define branches, click "Construct pipeline". Branches will be
automatically sorted and you can review them on a branch tree (clicking on
the desired branch) or in tables (clicking in any branch field in the table).
Assign fittings
For selected heating installation (marked on the branch tree) program passes
through all sections and sets fittings. This command adds only the reduction, t
pieces and couplings. All previously installed fittings will be deleted.
Table
From Starting section point. Program will automatically put endpoint of section in
column "To" (Note: first section must start with number 1).
To
section endpoint. After you finish with flow section input in table, you can do
return sections. In next table line for a starting point tipe again number 1, or
use "Copy flow or return sections" button.
L (m) section lenght
Fittings by double click on this column a new window will appear. Here you can
select fitting grups and number of fittings.
Device
Double-click in column field "Device" and select floor entry that is connected
to section endpoint. (here you connects floor to vertical pipeline section.
Duble click on the cell and choose floor entry for the pipeline section.)
Aws (l/s) water flow for drainage points
qs (l/s) total flow of building drainage
Gradient (%) pipe gradient
DN pipe inner diameter
Pipe pipe dimension
HORIZONTAL
Construct
pipeline
after you define branches, click "Construct pipeline". Branches will be
automatically sorted and you can review them on a branch tree (clicking on
the desired branch) or in tables (clicking in any branch field in the table).
Assign fittings
For selected heating installation (marked on the branch tree) program passes
through all sections and sets fittings. This command adds only the reduction, t
pieces and couplings. All previously installed fittings will be deleted.
Table
From Starting section point. Program will automatically put endpoint of section in
column "To" (Note: first section must start with number 1).
To
section endpoint. After you finish with flow section input in table, you can do
return sections. In next table line for a starting point tipe again number 1, or
use "Copy flow or return sections" button.
L (m) section lenght
Fittings by double click on this column a new window will appear. Here you can
select fitting grups and number of fittings.
Device
Double-click in column field "Device" and select floor entry that is connected
to section endpoint. (here you connects floor to vertical pipeline section.
Duble click on the cell and choose floor entry for the pipeline section.)
Aws (l/s) water flow for drainage points
qs (l/s) total flow of building drainage
Gradient (%) pipe gradient
DN pipe inner diameter
VENTILATION DUCTS
DEFAULT SETTINGS
Calculation selection for rectangular ducts:
Calculation
according to
hydraulic diameter
Calculation of rectangular ducts according to hydraulic diameter is
calculated by formula: Dh=4A/P (Dh - hydraulic diameter; A - Area of
ventilation duct cross-section; P - ventilation duct cross-section
perimeter).
Calculation
according to
ASHARE
Ventilation calculation by ASHARE, for diameters - according to
Huebscher (1948) formula. De=1,30(ab)0,625
/(a+b)0,250
(De - circular
equivalent of rectangular duct for same length, fluid resistance and flow,
mm ; a,b - sides of rectangular duct, mm
Default settings
Duct material select one of duct materials that program offer
(...) Material settings. Here you can check or change some basic material data
such as name, values of density and roughness.
Set if you change material, click "Set" button so that program can accept
changes.
Duct type Click on drop-down menu and select type of ventilation ducts (O - round
elements, P - rectangular elements)
Set if you change duct type, click "Set" button so that program can accept
changes.
Fresh air
temperature
(°C)/td>
Input value for temperature of fresh air. Program has entered a default
value that can be changed.
Set all if you press this button program will accept all changes that you made on
default settings window and use them in all ventilation ducts.
Calculation according to:
constant velocity Calculation according to constant velocity. If you do Calculation
according to this method, than enter velocity value. (w - velocity (m/s))
w - velocity (m/s) Velocity that should not be cross during this calculation.
constant pressure
drop
Calculation according to constant pressure drop If you do Calculation
according to this method, than enter pressure drop value. (R - pressure
drop (Pa))
R - pressure drop
(Pa) pressure drop that should not be cross during this calculation.
Element label
Fitting label
Program will show that fitting label in calculation. Default label depends
of program language (e.g. for english language it's F - (as Fitting).
Default label also can be changed.
Reset label if you change default fitting label press this button so that program can
accept changes.
Grill label
Program will show that grill label in calculation. Default label depends of
program language (e.g. for english language it's G - (as Grill). Default
label also can be changed.
Reset label if you change default grill label press this button so that program can
accept changes.
Duct element label
Program will show that duct element label in calculation. Default label
depends of program language (e.g. for english language it's EL - (as
Element Label). Default label also can be changed.
Reset label if you change default element label press this button so that program can
accept changes.
Duct dimensioning
Calculate by
constant (mm)
select this window if you want do dimensioning of rectangular duct
according to constant ducts width or height. Enter a constant value in
mm.
ducts width
select this radio button if you want do dimensioning of rectangular duct
according to constant ducts width. If the button is not visible select
"Calculate by constant (mm)"
ducts height
select this radio button if you want do dimensioning of rectangular duct
according to constant ducts height. If the button is not visible select
"Calculate by constant (mm)"
Max. aspect ratio Maximum aspect ratio for rectangular ducts. If this field is not visible
select "Calculate by constant (mm)"
VOLUME
Select volume calculation type
0 - Free entry
Volume calculation according to free entry value. In this calculation type,
it is necessary to input needed supply air volume (V su). Red row
represents heating values, and blue row represents cooling values. In this
type of calculation you don'’t need to write room dimensions (a, b, c, A,
V), fresh air temperature (tw) and inner room temperature (ti)
1 - Room
type/Number of
persons
Volume calculation according to room type and number of persons. In
this calculation type, it is necessary to input number of air exchange rate
(nr. of air ex.), number of persons that staying in the room (nr. of per.),
volume per person (V per. per.) and volume of 1m² of surface. Multiply
with room surface to get total room volume. Used with the type 1
calculation only if the resulting room volume is bigger than the
calculated volume from air exchange and number of persons (V per.
surf.). Required values can be written in field or selected from special
window by double clicking on field. Depending on data, program
calculates needed air flow volume. In this type of calculation data for
room dimension is required.
2 - Required
heating/cooling
capacity:
Volume calculation according to required heating/cooling capacity In this
calculation type it is necessary to input internal room temperature (ti),
fresh air temperature (tw) heat losses/ gains (Q) (losses - red row, gains -
blue row). Depending on data program calculates needed air flow
volume.
Set After you select one of three volume calculation type press this button so
that program can accept selected calculation.
Transfer pressing this button new window will appear where you can download
(transfer) heat losses or heat gains.
Table
Label Room label (same label as in project tree)
Room Room name
Type Volume calculation type (0 - free entry; 1 - room type/number of
persons:; 2 - required heating/cooling capacity:)
a (m) room length in m
b (m) room width in m
c (m) room height in m
A (m2) room area in m2
V (m3) room volume in m3
ti (°C) Internal room temperature in (°C)
tw (°C) fresh air temperature in (°C)
nr. of air ex. (h-1
) Number of air exchanges with fresh air during 1 hour in room
nr. of per. (n) number of persons in room
V per. per. (m3/h) needed air flow volume per person
V per surf.
(m3/(m2/h)) Needed air flow volume in one hour per square meter of room
V su. (m3/h) Sum of exchange Air flow volume
Q (W) Heat loss/gains
Help short description of the column from the table above where you are
positioned
Winter blue marked line in the table that displays cooling data
Summer pink marked line in the table that displays heating data
VENTILATION DUCTS
Add grille
You can add only one grill on each ventilation section. Procedure: click
on any cell of ventilation section where you want to add grille/ click on
"Add grille" button/ enter value of volume flow on grille/ select type of
ventilation ducts (round or rectangular)/ enter value of grille dimensions
(diameter for round grille or width and height of rectangular grille)/ enter
value of pressure drop on grille / click on "Add" button.
Add fitting
With fitting we connect ventilation sections. Procedure: Click on some
cell of ventilation section where fitting starts / Click on "Add fitting"
button (new window will appear) / In drop-down menu “Fitting group”
select which type of fitting you need. Program suggests possible groups
of fittings depending on number of continuing connected sections. /
Select fitting. If there is no listed fitting you want to put, select some
similar and manually input drag coefficients/ Specify ventilation sections
order / Input fitting technical data / Click on "Ok" button.
Add duct element
Ventilation element can be any part of ventilation who causes some
pressure change (e.g. silencer, flap…) and you can not add it on any other
way. Procedure: Click on some cell of ventilation section where you
want to add duct element./ Click on the "Add duct element" button (new
window will appear)/ Enter duct element name / Enter pressure drop
value/ Click on the "Add" button
Construct
ventilation pipeline
After changes in tabular calculation part click on this button and program
will recalculates pressure drop and dimensions of ventilation ducts. If
you don’'t want to recalculate dimensions of ventilation ducts turn off
option ''Reset ventilation duct dimensions''.
Show element ID
if this button is checked program will display ID column in down table.
(ID column displays fitting, grills or duct element labels) If button is
unchecked ID column will not be visible.
Δp max,i maximum pressure drop on ventilation installation. On branch tree select
branch for which you want to see this value.
Δp grane pressure drop on selected ventilation branch. On branch tree select
branch for which you want to see this value.
(+) Maximize table view (see all ventilation duct sections together with all
fittings, grills ...)
(-) Minimize table view (see just ventilation duct sections without fittings,
grills ...)
Table
From beginning of ventilation section
To end of ventilation section
V (m3/h) Volume flow
l (m) length of ventilation ducts section
Material ventilation duct material
type OP ventilation ducts type (O - round elements, P - rectangular elements)
D/a (mm) D - Diameter of round duct/ a - side A on rectangular duct
b (mm) Side B on rectangular duct
Dh (mm) Equivalent diameter of rectangular duct Calculation depends of selected
formula in default settings
s (mm) Thickness of ventilation duct material
w (m/s) Air velocity in ventilation duct
φ local pressure drop coefficient
R (Pa/m) major loss per meter of ventilation duct
R*l (Pa) major loss per section of ventilation duct
Z (Pa) minor loss on section (element of section)
R*l+Z (Pa) total head loss (pressure drop) on section of ventilation ducts
Print
Calculation and material list
After you complete your calculations, you can all datas and lists of materials arrange for printing in print module or, you can export and save them as a Microsoft Excel file. When you start the print module, program will automatically load his toolbars for editing data for printing. Switching from calculation print data to the other part, lists of materials, is enabled by using the vertical tab on the left edge of the print module (the same way as you switch between some parts of one calculation).
Calculation print:
Select "Print" module on the main IntegraCAD window and then click the vertical tab "Calculation".
When you click on that print module, program will automatically create those print calculations which you use in program (e.g. you used two pipe calaculaton (radiators) and heating pipeline calculation in that case program will automatically set these two calculations in his print module). If you selected all calculation in program, you will must use "Move" toolbar with four buttons to see them all, because all will not fit in print window. If you already at the beginning know what prints you will need, you can set them in the main Print menu of program. There are two possible ways: 1.) direct from the menu (shorter display)
2.) or by "Print options" button (in that menu) - graphically displays individual prints
Print editing is possible by program print toolbars or directly by typing and modifying data If later come to some changes in calculations, calculations data must be refreshed by
function Refresh print data located in the toolbar. Warning ! All manually entered datas and changes in the print list will be deleted by using that update function. That is why we recommend that first fully complete calculation part and than continue with editing. All prints created by the program are listed by lower left edge of the print window. You also can change currently displayed print list name by clicking on his name.
Lists of material:
Select "Print" module on the print window (if it is not already active), and then click the vertical tab "Material list". At the top of the window there are buttons for createing and some functions to work with a lists of materials like:
Insert list - create a new list of materials Delete list - delete the currently active list of materials Open - loading already creted material list (document with .ISD extension) Save - saveing active material list (document with have .ISD extension) Save as - saveing the material list under a different name Once you save material list as .ISD file you will can open it in any IntegraCAD program version, change it and save agein The difference between .INT file (project files) and .ISD file (list materials file) is that .INT file contains all information about a project, .ISD file only contains a list of materials, without calculations data, structure object data etc... Once created a material list can be changed at any time, but there is no automatic connection with calculation in which was created. If there is a change of some calculation, the list of material information can be refreshed using the function "Refresh data", or you can create a new print materials list that shows the current situation.
If you need you can have more different lists - made from the same project. To create a new list of materials, click on the button "Insert List" - new window will appear with all parameters for adjustment the new look for material list (insert on one list, on more lists, description types (long, short, without descriptions)
Function overwiew
Calculation print list can be arrange by special tools on the toolbar.
PRINT: Export to excel - functions that exports program data in Excel (xls) file.
OPTIONS: Add total price - this function add column with total price in print list Price properties- price options (e.g. discounts, tax...)
BILL OF MATERIAL: Insert row - program insert rows in the table Delete row - program delete rows in the table Refresh data- with this funkcion program do refreshing for some changed data Undo - Undo the last operation Redo - this function cancel Undo function Align left - align left text and/or numbers in print list Center - center yours text and/or numbers in print list Align right - aligns right text and/or numbers in print list Sort by number - sort by number in print list Most of the functions in this menu you can also choose from the toolbar List
If you click whith right mouse button on some print list, program will open up additional menu from which you also can call some standard functions like "Insert Row", "Delete Row" cut, copy, paste ...
TEXT: Bold, Italic, Underline - editi letter style Font size - select font size from the drop-down menu Font type - select font type from the drop-down menu Cell color - an additional dialog will appear in which you can choose one of the listed colors, or create your own colors from the palette attributed. Cell color - an additional dialog will appear in which you can choose one of the listed colors, or create your own colors from the palette attributed. Print language - Choosing one of the available languages from the drop-down menu you can translate the prints on several language. This function can translate all the text that was created with this program. (titles, calculation names, table names etc.) and some of products (if we have translation for tham in program database). This function can not translate the text that user alone add in print list. Most of the functions in this menu you can also choose from the Text toolbar
CAD
CAD drawing basics
Drawing in IntegraCAD is alike any CAD drawing. At the beginning you can connect the drawing with flat or you can make a new drawing.
Standard toolbars for drawing are at the right side of CAD window. Also there are toolbars with special tools. That tools are tended for drawing of heating elements, drop the radiators and manifolds, draw floor heating pipelines, heating pipelines and water system pipelines.
For the CAD drawings it is recommended to use SNAP function for connecting pipes and heating or cooling elements.
CAD function overwiew
English Croatian Command Line Function description
- DRAWING -
Line Crta LINE
Creates straight line segments Integra CAD draws a line segment and continues to prompt for points. You can draw a continuing series of line segments, but each line segment is a separate object. Specify first point: Specify a point Specify next point or [Close/Undo] Finish command with right click or choosing Close Close: Ends the last line segment at the beginning of the first line segment, which forms a closed loop of line segments. You can use Close after you have drawn a series of two or more segments. Undo: Erases the most recent segment of a line sequence. Entering u more than once backtracks through line segments in the order you created them.
Arc Luk ARC
Creates an arc defined by center and radius Specify center of arc Specify radius of arc Specify first point of arc Specify last point of arc
3T 3T ARC3T
Creates an arc defined by 3 points Specify first point of arc Specify last point of arc Specify point on arc
Circle Krug CIRCLE
Creates circle defined by center and radius Specify center point Specify radius of circle: enter value or specify point. (The distance between this point and the center point determines the radius of the circle.)
Circle 2P Kružnica 2T CIRCLE2T
Creates circle defined by two points Specify first point on circle Specify second point on circle
Circle 3P Kružnica 3T CIRCLE3T
Creates circle defined by three points Specify first point on circle Specify second point on circle Specify third point on circle
Elipse Elipsa ELLIPSE
Creates the ellipse defined by center point, endpoint of one axis and radius to other axis Specify center of ellipse Specify endpoint of axis Specify distance to other axis
Polyline Polilinija PLINE
Creates 2-dimensional polyline (connected lines forming one object) Specify start point: Specify a point Specify next point or [Close/Undo] Close: Ends the last line segment at the beginning of the first line segment, which forms a closed loop of line segments. You can use Close after you have drawn a series of two or more segments. Undo: Erases the most recent segment of a line sequence. Entering u more than once backtracks through line segments in the order you created them.
Rectangle Pravokutnik RECT
Draws a rectangular polyline Specify one corner of rectangle Specify opposite corner of rectangle
Text Tekst TEXT
Command for writing single line text Specify where you want to start Specify direction of writing Write text Press Enter for finish
Aligned Dimension
Položena kota DIMALI
Creates an aligned linear dimension Specify first extension line orgin Specify second extension line Specify location of dimension line
Vertical Dimension
Vertikalna kota
DIMVER
Creates an vertical linear dimension Specify first extension line orgin Specify second extension line Specify location of dimension line
Horizontal Dimens.
Horizontalna kota
DIMHOR
Creates an horizontal linear dimension Specify first extension line orgin Specify second extension line Specify location of dimension line
Angular Dimension
Kotiranje kuta ""
Creates an angular dimension Specify angle vertex: Specify a point (1) Specify first angle endpoint: Specify a point (2) Specify second angle endpoint: Specify a point (3) Specify dimension line location
Quick dimension
Brzo kotiranje QDIM
Creates quick dimension Specify line for Dimension: Specify location of dimension line
Diameter Dimension
Kotiranje promjera
DIMDIA
Creates diameter dimensions for circles and arcs Specify circle or arc
Radial Dimension
Kotiranje polumjera
DIMRAD
Creates radial dimensions for circles and arcs Specify circle or arc
Make Block Stvori blok MBLOCK
Creates a block definition from objects you select Block name: Specify insertion point: Select entities
Insert block Umetni blok INSERT
Places named block into the current drawing Opens dialog box where you can define insertion point, scale and rotation. By clicking on checkbox you can select insertion point, scale and rotation on screen.
Write Block Zapiši blok WBLOCK Opens dialog box to save block in file
Picture Slika IMAGE
Opens dialog box to import image in file Select image to import Specify insertion point
xRef xRef XREF Specify external reference
Select fonts Odabir fontova
STYLE Select where font files are located
- MODIFICATION -
Erase Brisanje ERASE
Removes objects from a drawing Select the objects to erase and press ENTER
Move Pomicanje MOVE
Displaces objects a specified distance in a specified direction Select entities: Move from point: Move to point:
Copy Kopiranje COPY
Duplicates objects Select entities: Copy from point: Copy to point
Rotate Rotiranje ROTATE
Moves objects about a base point Select entities Rotation base point Rotation angle (write or select with mouse)
Scale Skaliranje SCALE
Enlarges or reduces selected objects proportionally in the X, Y, and Z directions Select entities Specify base point Specify scale factor
Explode Eksplodiranje EXPLODE
Breaks a compound object into its component objects Select entities
Stretch Razvuci STRETCH
Moves or stretches objects Select entities Window select 1st point Window select 2nd point (Inside of the window are points which will be streched) Strech from point Move to point
Extend Proširi EXTEND
Extends an object to meet another object Select entities Select entities to extend (first select where to select, then what to extend)
Trim Odreži TRIM
Trims objects at a cutting edge defined by other objects Select entities Select entities to trim (first select where to select, then what to trim)
Offset Offset OFFSET
Creates concentric circles, parallel lines, and parallel curves Select entitiy to offset Offset distance Side to offset
Break Prekini BREAK
Breaks the selected object between two points Select entity Select first break point Select second break point
Fillet PolyLine
Zaobli poliliniju
FILLET
Rounds and fillets the edges of polyline Fillet radius Specify polyline
Mirror Zrcali MIRROR
Creates a mirror image copy of objects Select entities Specify first point on mirror line Specify second point on mirror line
Distance Udaljenost DIST
Measuring distance between selected points Specify first point Specify second point After specifiying all wanted points, with right click finish command. Distance is printed in command line (in real units – if drawing is made in mm, distance will be printed in mm with no regard to mesure we set) Useful for determing units in which drawing is created.
- OSNAP -
When one or more OSNAP (Object snap) buttons is turned on, you can specify required point at an exact location on an object. When more options are selected INTEGRACAD applies the selected snap modes to return a point closest to the
cursor.
Osnap End (Alt + E)
Osnap End (Alt + E)
Snaps to endpoint of line, arc, polyline, object
Osnap Mid (Alt + M)
Osnap Mid (Alt + M)
Snaps to midpoint of line, arc, polyline segment
Osnap Cen Osnap Cen Snap to center of circle or arc
(Alt + C) (Alt + C)
Osnap Per (Alt + P)
Osnap Per (Alt + P)
Snaps to a point perpendicular to an arc, line, circle, polyline...
Osnap Nea (Alt + N)
Osnap Nea (Alt + N)
Snaps to nearest point on object It is recommened to turn on only when is needed (because of easier selection of other osnap points)
Osnap Int (Alt + X)
Osnap Int (Alt + X)
Snaps to a point in extension of lines for to selected objects (apparent intersection) When using this osnap it i needed to click twice to snap on point! Select first object By moving mouse cursor near other objects, program is calculatinng where would be intersections with other objects. You select one intersection. If first object is selected with this osnap, you can't use osnap points other than apparent intersections. It is recommened to turn on only when is needed (because of easier selection of other osnap points)
Osnap None
(Alt + K)
Osnap None (Alt + K)
Turn off all osnap functions
Osnap Osnap Dialog Dialog box for selecting osnap
Dialog (Alt + O)
(Alt + O) functions.
Recommended osnap functions turned on Insertion - snap to point of block insertion Node (point) - snap to single point Quadrant - snaps to a quadrant point of an arc, circle, ellipse. Quadrant point are located on intersections of imaginary coordinate system with origin in center of object (direction of x and y axis od coordinate system are same as current UCS). Osnap Quadrant is on priority list before osnap center, and is recommnded to turn it on only in case of need. Tangent - enables selection tangent vertex on the circle, ellipse or a circular arc Intersection (one point) - select intersection of two objects
- ZOOM - Window, Extents, Previous, In, Out, All -
Window Prozor ZW
Zooms to display an area specified by two opposite corners of a rectangular window Specify first corner Specify opposite corner
Extents Do zaslona ZE Zooms to display the drawing extents and results in the largest possible display of all the objects.
Previous Prethodni ZP Zooms to display the previous view.
In Povećaj ZI Zoom in for default value Use mouse scroll up to zoom in
Out Smanji ZO Zoom out for default value Use mouse scroll down to zoom out
PAN Naredba PAN PAN
Shifts location of view in any direction. While pan cursor is active (hand instead of cross), press point on the screen and move mouse in wanted direction you want to move view location. You can activate pan by clicking middle mouse button. In this case press point on screen with middle mouse button and drag cursor to direction you want and release middle mouse button.
All Sve Zooms to display the entire drawing in the current viewport.
- LAYER -
Layers are primary organizational tool in INTEGRACAD. Similar objects we can associate similar objects in same layer. For example you can separate construction lines, text, dimension lines in separate layers. For every layer we can control name, colour, linetype and lineweight. Layers can be frozen (forzen layer is invisible and excluded from regeneration and plotting) and locked (objects are visible but can't be edited or selected). INTEGRACAD uses specific layers for drawing hot and cold water pipes. If you draw lines in other CAD program, layer has to be exactly the same as INTEGRACAD layer, otherwise collectiong pipeline won't work. Turning freeze on and of on some layers, drawing becomes more clear and it is easier to manage inside of it. Creating layers: 1. Open dialog box manage layers 2. Write the name of the layer 3. Click on button New layer 4. Find it in table below, click on the row and modify if needed. Click on the button „Set current“ to make layer active.
Layer Properties Manager
Shoutcout for command is LAYER
<>
- PIPE -
Flow water pipe
drawing
Crtanje cijevi polaza tople
vode PIPEHOT
Draw flow water pipe. Pipes are drawn like polylines
Return water pipe
drawing
Crtanje cijevi povrata
hladne vode PIPECOLD
Draw return water pipe. Pipes are drawn like polylines
Warm and cold water
pipe drawing
Istovremeno crtanje polaza
i povrata DOUBLEPIPE
Simultaneusly draw flow and return water pipes.First you draw flow pipe and then clik side to automaticly draw return water pipe.
Drawing cold water
pipes
Crtanje cijevi hladne vode
PIPECOLDWATER
Draw cold water pipes. Pipes are drawn like polylines
Drawing hot water
pipes
Crtanje cijevi tople vode
PIPEHOTWATER Draw hot water pipes. Pipes are drawn like polylines
Circulation pipe
drawing
Crtanje cijevi cirkulacije
PIPECIRC Draw circulation pipes. Pipes are drawn like polylines.
Drainage pipe
drawing
Crtanje cijevi odvodnje
PIPEDRAIN Draw drainage pipes. Pipes are drawn like polylines.
Join sections
Spajanje dionica
Joint sections – joint pipes which are connected in one ending point to become one pipe. Specify first section Specify second section
Section break
Prekid dionice Secton break – divides section in two sections Specify break point
Lowering pipe height
Spustanje cijevi na visinu
Lowering pipe height- Only in UCS (user specified coordinate system) Specify place which you want to lower on height of world coordinate system Specify place where you want to lower on height of world coorinate system Program draws line from first point to second point in user specified coordinate system (UCS), in second point program lowers line to height of world UCS (height z=0)
pipeline cjevne mreže Specify area where you want to construct pipeline. Pipes (lines representing pipes) must be conected to radiators/fan coils and floor entry points. Every radiator and fan coil must have specific identification number (they should't be coopied from the drawing, you have top add them from list of equipement)
Integrity pipeline check
Provjera integriteta
cijevne mreze
Integrity check of pipeline Turn it on and off before using command construct pipeline. If it is on, connstruct pipeline won't make calculation of pipeline. It will just make check if all the lines are correctly connected in CAD drawing.
Element selection
Označavanje elemenata
You can mark pipes, radiators, manifolds and other elements of pipeline. After turning command on, you have to choose element you want to mark (e.g. pipe). Select location you want to place mark (you can see it while moving mouse). Mark is writen like block and you need to use command Explode if you want to edit text.
Generate riser
scheme
Stvaranje sheme
usponskih vodova
Before generating riser scheme you have to select branch on instalation tree. Program draws scheme of instalations in new drawing (command for generating scheme stays pressed and indicates working on riser scheme). After editing riser scheme you need to save it using standard command save drawing. For return on groung plan you have to turn off command generate riser scheme by pressing it again and after that click on floor. WARNING: compulsory save ground plan before generating riser scheme.
Elements Automatsko Automatic elements connection
automatic connection
spajanje elemenata
From right to left select elements you want to connect From right to left select pipes where you want to join elements.
- 3D VIEW -
WORLD WORLD WORLD
Basic coordinate system of drawing Orgin point is (0,0,0) and axis are in direction od main axis
UCS UCS UCS User defined coordinate system by current view
UCS from 3 points
UCS iz 3 točke
UCS
User defined coordinate system by three points Specify orgin point of UCS Specify height of orgin point Specify point in x direction Specify height of the point on x direction Specify point in y direction Specify height of the point on y direction
UCS object UCS objekt UCS Used defined coordinate system defined by object coordinates.
View top Pogled odozgo
Top view (plane X-Y) – ground plan
View bottom
Pogled odozdo
Bottom view (plane X-Y)
View left Pogled s
lijeva Left view (plane Y-Z ) – body plan
View right Pogled s desna
Right view (plane Y-Z)
View front Prednji pogled Front view (plane X-Z) � plan
View back Stražnji pogled
Back view (plane X-Z)
View SW Pogled SW 3D view from South-West
View SE Pogled SE 3D view from South-East
View NE Pogled NE 3D view from North-East
View NW Pogled NW
3D view from North- West
Rotate3D 3D rotiranje Rotate view around 3D axis
Dynamic Click point on the screen with first mouse button, hold and rotate view by moving mouse. Move view by presing and holding middle mouse button.
Top view Pogled odozgo
View te orgin of current UCS on specific height
Object view Pogled objekta
View acording to selected point of view and point to view Specify point of view
- UCS VIEW -
UCS view UCS pogled
Click on icon for saving current UCS Write the name of UCS Click on OK Saved UCS you can select in any moment in drop down box located in toolbar UCS view.
delete selected UCS view.
- EDIT -
Undo Poništi U UNDO actions in CAD, can be activated multiple times.
Redo Ponovi REDO REDO actions canceld with UNDO.
- LOOP -
Automatic parallel loop
drawing
Automatsko crtanje
paralelne petlje
Automatic parallel loop drawing tool Specify area of room which will be covered with floor heating. (Specify end points of room, when you select last point, click right mouse button to connect it with first point) Specify entry point... (You specify where loop will enter the room) Window pops up where you have to select manifold on which loop is connected. After that you have to select distance between pipes in the loop, offset from wall and direction of drawing loop. Default way of drawing floor heating is counterclockwise. It is recommended to choose direction on longer side.
Automatic double
parallel loop drawing
Automatsko crtanje duple
paralelne petlje
Automatic double parallel loop drawing tool Specify area of room which will be covered with floor heating. (Specify end points of room, when you select last point, click right mouse button to connect it with first point) Specify entry point... (You specify where loop will enter the room) Window pops up where you have to select manifold on which loop is connected. After that you have to select distance between pipes in the loop, offset from wall and direction of drawing loop. Default way of drawing floor heating is counterclockwise. It is recommended to choose direction on longer side.
Automatic spiral loop
Automatsko crtanje
Automatic spiral loop drawing tool Specify area of room which will be
drawing spiralne petlje covered with floor heating. (Specify end points of room, when you select last point, click right mouse button to connect it with first point) Specify entry point... (You specify where loop will enter the room) Window pops up where you have to select manifold on which loop is connected. After that you have to select distance between pipes in the loop, offset from wall and direction of drawing loop. Default way of drawing floor heating is counterclockwise. It is recommended to choose direction on longer side.
Cut part of loop
Izreži dio petlje
Cut part of loop Specify first point to cut Specify second point to cut
Reset loop label
Ponovno postavi
oznake petlji
Reset loop label Take name from calculation and set it on CAD drawing
Calculate loop length
Proracunaj stvarne duljine
petlji
Calculate loop length Program calculates real length of loops from CAD drawing.
- TOOLS -
Set room area
Postavi površinu prostorije
Tool for seting room area Select room from project Specify end points of room, when you select last point, click right mouse button to connect it with first point Program calculates room area
Read wall length
Preuzmi dužinu zida
Tool for specifying wall length Click two times in calculation field
where you want to take length from drawing. Drawing is automaticly opened. Select points you want to measure from drawing. Length you measure is scaled depending on measure set for dwg file in info tab.
Hide foreing layers
Sakrivanje stranih slojeva
Tool for freezing all non INTEGRACAD layers
Set drawing reference
point
Postavi baznu točku crteža
set drawing reference point
Finalize loop
drawing
Završna obrada petlji
podnog grijanja
Select floor heating loop. Loop edges are rounded and second half of the loop is transfered in layer return.
- VENTILATION CANALS -
Draw supply
ventilation ducts
Crtanje dovodnih
ventilacijskih kanala
Draw supply ventilation ducts. Pipes are drawn like polylines Options: draw rectangular and circular ventilation ducts.
Draw drainage
ventilation ducts
Crtanje odvodnih
ventilacijskih kanala
Draw drainage ventilation ducts. Pipes are drawn like polylines Options: draw rectangular and circular ventilation ducts.
Setting up a network of ventilation
ducts
Postavljanje mre�e
ventilacijskih kanala
Setting up a network of ventilation ducts Specify area where you want to construct network of ventilation ducts. Ventilation ducts must be conected to floor entry points.
Mark Označi Mark ventilation element
ventilation element
element ventilacije
After turning command on, you have to choose element you want to mark. Select location you want to place mark (you can see it while moving mouse). Mark is writen like block and you need to use command Explode if you want to edit text.
Admin
Introduction
Admin is a simple tool for radiator or room input into program, if they do not exist in it.
Starting the admin module:
Menu -> Edit -> Admin (Picture 1)
Picture 1
WINDOW DESCRIPTION:
Main Admin menu File - used to manage basic admin functions. New - creates a new project, Open - opens an existing project, Close - closes the active project, Save - saves the active project, Save as ... - saves the project named as, Recent file - , Exit - used to exit the Admin. Edit - this menu contains standard data editing tools. Undo - move previous command, Cut - cuts data (makes a copy but doesn't keep the original); Copy - for copying data (makes a copy and keeps the original; Paste - pastes cut or copied data on a chosen place. View - turns off/on status bar window. Window - contains some standard window options like: New window, Cascade, Tile, Arange icons, 1 Admin (currently open admin window). Help - short informations about current Admin version
Function selection program have two admin functions Radiators and Room
working area - window view depends on your selection (radiator or room)
Admin radiators
(Note! All changes will be visible only after you restart program.). Input radiators in the program database
First table:
insert radiator manufacturer. Press " Add new " button and write manufacturer name. Confirm your input name pressing " Add " button, or cancel this step pressing " Cancel " button.
insert radiator group name Note! first you must enter radiator manufacturer because without this inforamtion radiator admin will not work
insert radiator Type - 0 - for panel radiators, 1 - for glide radiators
insert radiator short Description- (Note: this is optional field)
Erase- mark this field and erase one radiator group from program database.
Second table:
Radiator name - radiator (e.g. Radiator XL 358/500)
Height - Radiator height in mm
Length - Radiator length in mm
Depth - Radiator depth in mm
n - exponent (If you don't know this information input 1,30 as the standard for all radiators
Surface - Radiator surface in m2 (Note: this is optional field)
Volume - radiator volume in liter (Note: this is optional field)
Mass - radiator mass in kg (Note: this is optional field)
q60 - radiator capacity in (W) according to DIN4703/4 for temperature regime 90/70/20 °C
q50 - radiator capacity in (W) according to EN442 for temperature regime 75/65/20 °C
Erase - mark this field and erase one radiator from radiator group in program database Every change you make and want to keep press Refresh button to confirm that information.
Admin room
(Note! All changes will be visible only after you restart program.)
Input new room in the program database
enter the following data in table:
Room name - input new room name
Temperature - average room temperature
W / m2 - input watt per square meter for underfloor heating
Air exchange - input air exchange for a period of one hour
Erase - mark and earse rooms one or more rooms from list and from program database
Every change you make and want to keep press Refresh button to confirm that information.
You can purchase IntegraCAD 2011 in seven different packages: * Sani * Duct * Termo * Professional * Suite * Premium * Enterprise The program packages include the same program framework (program interface, CAD, print, database) but a different amount of calculation modules. You can compare the different packages in the table below:
Download last program version from web site
If you buy or update one of our IntegraCAD 2011 program licence packages (see chapter IntegraCAD packages in this help) then you'll get for free all last program versions in your licence time period (30; 90 or 365 days).
Versions are available for download on the official IntegraCAD website (0-24h), for all IntegraCAD users. New software upgrade comes out every 3 months, and after we release a new version you'll get notification on your email.
DOWNLOAD PROCEDURE:
* please open www.integracad.com * in upper right corner press Customer area (cro. lang. Partnerske stranice)
* please enter your username and password: (to download the new program version, video help or some additional content you must be logged in. New designed web page has improved security system and most of old user name and passwords is no longer valid, so please make sure that your new access data that we have sent to you by e-mail, because maybe we changed it. If you have any problems with access please contact us on telephone: +381 51 545 880 or on e-mail: [email protected]) User name (cro. lang. Korisničko ime): xxxxxxx Password (cro. lang. Lozinka): xxxxxxx
* Click on Login button (cro. lang. Prijava) * If everything is OK, the following window will appear:
After you download the latest IntegraCAD program version (e.g. on your Desktop) you will receive IntegraCAD .zip file Unzip IntegraCAD file to get IntegraCAD 2011 Setup.exe (you can also do that on your Desktop) � after that you're ready to install program
WARNING !!! Before installing the new program version, uninstall the old one from your computer !!!
Internet training
We offer Internet support through a specialised web conferencing system. During the conference the participants can see the presenters screen and follow the session in real time. All users see the same video output (the presenters screen) and can communicate with each other through a live audio connection.
An Internet presentation is the simplest and fastest way to experience the capabilities of the program. Without generating costs and with a minimum time investment, everybody with an interest in the program can get the answers to his/her questions. The presentation will give you a general overview of the software without discussing the fine points. After the presentation phase there will be time for Q&A and a possibility to explore some questions deeper. Program presentations can be individual or public.
Getting help for a current issue has never been easier. Program users can contact us by phone, e-mail or Skype and we will organize a support session as soon as possible. You can ask general questions (how to start a program function, avoid problems, etc.) or questions related to a current project. In general, the explanations will be made with standard support projects. For bigger issues, you can send us your project and drawing files and we will do our best to help. If the problems cannot be resolved during the support session, we will transfer them to our standard technical support procedure.
Internet training allows for a thorough insight into a part of the program. As a program user you have two options: you can request an individual training or you can join one of the regular public trainings. In the first case you can select the training topic freely but you need to make your training request at least 7 days in advance. In the case of public trainings the topic and date are already set and you need to apply at least 24 hours in advance. Public training dates will be announced on our website www.integracad.com at least two weeks in advance.
TECHNICAL PREREQUISITES
Internet Fast connection (DSL, optical cable)
Software Mozilla Firefox 3.5 or Internet Explorer 8
E-mail client for the initial communication
Hardware
Headphones and microphone compatible to Windows OS
Contact
Contacts
We thank you for using our software. If you need help or have suggestions or improvement requests do not hesitate to contact us: