Insulthane a Division of Elastochem a www.Elastochem-ca.com/insulthane Sealant Sealant Sealant Note: Closed-cell spray foam insulation thickness to meet local code requirements. Minimum thickness of 2" (50mm) required when installed as a vapor retarder. CONDITIONED SPACE CONDITIONED SPACE CONDITIONED SPACE Rigid backing to support insulation D1.1b Dec. 5, 2011
34
Embed
Insulthane a Division of Elastochem ...Dec 05, 2011 · CONDITIONED SPACE CONDITIONED BASEMENT Note: Closed-cell spray foam insulation thickness to meet local code ... Vented Crawl
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Insulthane a Division of Elastochem a
www.Elastochem-ca.com/insulthane
Sealant
Sealant
Sealant
Note:Closed-cell spray foam insulation thickness to meet local code requirements.
Minimum thickness of 2" (50mm) required when installed as a vapor retarder.
CONDITIONEDSPACE
CONDITIONED SPACE
CONDITIONED SPACE
Rigid backing tosupport insulation
D1.1bDec. 5, 2011
Insulthane a Division of Elastochem 37 Easton Rd Brantford, On N3P 1J4, Canada
www.Elastochem-ca.com/insulthane
Wall Section, Conditioned Basement
Sealant
CONDITIONED SPACE
CONDITIONEDBASEMENT
Note:Closed-cell spray foam insulation thickness to meet local code requirements.
Minimum thickness of 2" (50mm) required when installed as a vapor retarder.
Note:Concrete must cure at least 28 days prior to spray foam application. Concrete must be free of oil/release agents prior to application of spray foam insulation. Surface may require priming.
Spray foam insulationoptional at grade
D1.2Dec. 5, 2011
EXTERIOR
Insulthane a Division of Elastochem 37 Easton Rd Brantford, On N3P 1J4, Canada
www.Elastochem-ca.com/insulthane
Wall Section, Non-Conditioned Basement
Sealant
Note:Closed-cell spray foam insulation thickness to meet local code requirements.
Minimum thickness of 2" (50mm) required when installed as a vapor retarder.
NON-CONDITIONEDBASEMENT
CONDITIONED SPACE
D1.3Dec. 5, 2011
EXTERIOR
Insulthane a Division of Elastochem 37 Easton Rd Brantford, On N3P 1J4, Canada
www.Elastochem-ca.com/insulthane
Wall Section, Vented Crawl Space
VENTEDCRAWL SPACE
CONDITIONED SPACE
Note:Closed-cell spray foam insulation thickness to meet local code requirements.
Minimum thickness of 2" (50mm) required when installed as a vapor retarder.
SealantRadiant
Floor
D1.4Dec. 5, 2011
EXTERIOR
Insulthane a Division of Elastochem 37 Easton Rd Brantford, On N3P 1J4, Canada
www.Elastochem-ca.com/insulthane
Wall Section, Sealed Crawl Space
SEALEDCRAWL SPACE
CONDITIONED SPACE
Note:Closed-cell spray foam insulation thickness to meet local code requirements.
Minimum thickness of 2" (50mm) required when installed as a vapor retarder.
SealantRadiant
Floor
Spray foam insulationoptional at grade
D1.5Dec. 5, 2011
EXTERIOR
Insulthane a Division of Elastochem 37 Easton Rd Brantford, On N3P 1J4, Canada
www.Elastochem-ca.com/insulthane
Wall Section, Cantilevered FloorOption A
CONDITIONED SPACE
CONDITIONEDSPACE
Note:Closed-cell spray foam insulation thickness to meet local code requirements.
Minimum thickness of 2" (50mm) required when installed as a vapor retarder.
Sealant
D1.6aDec. 5, 2011
Sealant
EXTERIOR
Insulthane a Division of Elastochem 37 Easton Rd Brantford, On N3P 1J4, Canada
www.Elastochem-ca.com/insulthane
Wall Section, Cantilevered FloorOption B
CONDITIONED SPACE
CONDITIONEDSPACE
Note:Closed-cell spray foam insulation thickness to meet local code requirements.
Minimum thickness of 2" (50mm) required when installed as a vapor retarder.
Sealant
D1.6bDec. 5, 2011
Sealant
Provide rigid backingto support insulation
EXTERIOR
Insulthane a Division of Elastochem 37 Easton Rd Brantford, On N3P 1J4, Canada
www.Elastochem-ca.com/insulthane
Wall Section, Finished Basement
Sealant
CONDITIONED SPACE
CONDITIONEDBASEMENT
Note:Closed-cell spray foam insulation thickness to meet local code requirements.
Minimum thickness of 2" (50mm) required when installed as a vapor retarder.
Note:Concrete must cure at least 28 days prior to spray foam application. Concrete must be free of oil/release agents prior to application of spray foam insulation. Surface may require priming.
Spray foam insulationoptional at grade
D1.7Dec. 5, 2011
EXTERIOR
Insulthane a Division of Elastochem 37 Easton Rd Brantford, On N3P 1J4, Canada
www.Elastochem-ca.com/insulthane
Wall Section, Garage with ConditionedSpace Above and Adjoining
CONDITIONED SPACE
CONDITIONEDSPACE
NON-CONDITIONEDGARAGE
Note:Closed-cell spray foam insulation thickness to meet local code requirements.
Minimum thickness of 2" (50mm) required when installed as a vapor retarder.
Sealant
D1.8Dec. 5, 2011
Insulthane a Division of Elastochem 37 Easton Rd Brantford, On N3P 1J4, Canada
www.Elastochem-ca.com/insulthane
Wall Section, Basement Exterior
D1.9Dec. 5, 2011
Sealant
CONDITIONED SPACE
CONDITIONEDBASEMENT
Note:Closed-cell spray foam insulation thickness to meet local code requirements.
Minimum thickness of 2" (50mm) required when installed as a vapor retarder.
Note:Concrete must cure at least 28 days prior to spray foam application. Concrete must be free of oil/release agents prior to application of spray foam insulation. Surface may require priming.
Spray foam insulationoptional at grade
EXTERIOR
Insulthane a Division of Elastochem 37 Easton Rd Brantford, On N3P 1J4, Canada
www.Elastochem-ca.com/insulthane
Wall Section, Garage with ConditionedSpace Adjoining
D1.10Dec. 5, 2011
Sealant
CONDITIONED SPACE
CONDITIONED SPACE
NON-CONDITIONEDGARAGE
Note:Closed-cell spray foam insulation thickness to meet local code requirements.
Minimum thickness of 2" (50mm) required when installed as a vapor retarder.
Note:Closed-cell spray foam insulation thickness to meet local code requirements.
Minimum thickness of 2" (50mm) required when installed as a vapor retarder.
Note:Concrete must cure at least 28 days prior to spray foam application. Concrete must be free of oil/release agents prior to application of spray foam insulation. Surface may require priming.
Spray foam insulationoptional at grade
Sealant
Insulthane a Division of Elastochem 37 Easton Rd Brantford, On N3P 1J4, Canada
www.Elastochem-ca.com/insulthane
Wall Section, Garage wall Connection
D1.11Dec. 5, 2011
Sealant
CONDITIONED SPACE
CONDITIONED SPACENON-CONDITIONEDGARAGE
Note:Closed-cell spray foam insulation thickness to meet local code requirements.
Minimum thickness of 2" (50mm) required when installed as a vapor retarder.
Rigid backing tosupport insulation
Insulthane a Division of Elastochem 37 Easton Rd Brantford, On N3P 1J4, Canada
www.Elastochem-ca.com/insulthane
Wall Section, Window Unit
D1.12Dec. 5, 2011
CONDITIONED SPACE
CONDITIONED SPACE
Note:Closed-cell spray foam insulation thickness to meet local code requirements.
Minimum thickness of 2" (50mm) required when installed as a vapor retarder.
Sealant
Sealant
Low-expansionfoam insulation
EXTERIOR
Insulthane a Division of Elastochem 37 Easton Rd Brantford, On N3P 1J4, Canada
www.Elastochem-ca.com/insulthane
Wall Section, Typical Wood-FramedWall with Siding
D1.13Dec. 5, 2011
EXTERIORCONDITIONED SPACE
Note:Closed-cell spray foam insulation thickness to meet local code requirements.
Minimum thickness of 2" (50mm) required when installed as a vapor retarder.
Insulthane a Division of Elastochem 37 Easton Rd Brantford, On N3P 1J4, Canada
www.Elastochem-ca.com/insulthane
Wall Section, Typical Wood-Framed Wall with Masonry Veneer
D1.14Dec. 5, 2011
EXTERIORCONDITIONED SPACE
Note:Closed-cell spray foam insulation thickness to meet local code requirements.
Minimum thickness of 2" (50mm) required when installed as a vapor retarder.
Insulthane a Division of Elastochem 37 Easton Rd Brantford, On N3P 1J4, Canada
www.Elastochem-ca.com/insulthane
Wall Section, Unheated Atticwith Mechanical Chase
D1.15Dec. 5, 2011
SEMI-CONDITIONED SPACE
CONDITIONED SPACE
Note:Closed-cell spray foam insulation thickness to meet local code requirements.
Minimum thickness of 2" (50mm) required when installed as a vapor retarder.
Rigid backing tosupport insulation.
Seal all electrical and plumbingpenetrations through top andbottom plates.
Sealant
Duct work chase
Fire stoparound duct
EXTERIOR
Insulthane a Division of Elastochem 37 Easton Rd Brantford, On N3P 1J4, Canada
www.Elastochem-ca.com/insulthane
Wall Section, Cathedral Ceiling with Skylight
D1.16Dec. 5, 2011
NON-CONDITIONED SPACE
CONDITIONED SPACE
CONDITIONED SPACE
Note:Closed-cell spray foam insulation thickness to meet local code requirements.
Minimum thickness of 2" (50mm) required when installed as a vapor retarder.
Sealant
Wind baffle may be requiredto obtain full insulation depth
Rigid backing tosupport insulation
Sealant
Sealant
Sealant
Low-expansionfoam insulation
EXTERIOR
Insulthane a Division of Elastochem 37 Easton Rd Brantford, On N3P 1J4, Canada
www.Elastochem-ca.com/insulthane
Wall Section, Flat Roof with Deck
D1.17Dec. 5, 2011
CONDITIONED SPACE
ROOF DECK(EXTERIOR)
Note:Closed-cell spray foam insulation thickness to meet local code requirements.
Minimum thickness of 2" (50mm) required when installed as a vapor retarder.
Sealant
Insulthane a Division of Elastochem 37 Easton Rd Brantford, On N3P 1J4, Canada
www.Elastochem-ca.com/insulthane
Wall Section, Cantilevered Bay Window
D1.18Dec. 5, 2011
CONDITIONEDSPACE
CONDITIONED SPACE
A A
PLAN VIEW OF SECTION A-A
EXTERIOR
CONDITIONED SPACE
EXTERIORNote:Closed-cell spray foam insulation thickness to meet local code requirements.
Minimum thickness of 2" (50mm) required when installed as a vapor retarder.
SealantSealant
Sealant
Sealant
Rigid backing tosupport insulation
Insulthane a Division of Elastochem 37 Easton Rd Brantford, On N3P 1J4, Canada
www.Elastochem-ca.com/insulthane
Wall Section, Pole Framed-Structure
D1.19Dec. 5, 2011
A A
PLAN VIEW OF SECTION A-A
NON-CONDITIONED SPACE
CONDITIONED SPACE
CO
ND
ITIO
NED
SPA
CE
Note:Closed-cell spray foam insulation thickness to meet local code requirements.
Minimum thickness of 2" (50mm) required when installed as a vapor retarder.
Sealant
Wind baffle may be requiredto obtain full insulation depth
Spray foam insulationoptional at grade
EXTERIOR
EXTE
RIO
R
Insulthane a Division of Elastochem 37 Easton Rd Brantford, On N3P 1J4, Canada
www.Elastochem-ca.com/insulthane
Wall Section, Sound-Attenuating Wall
D1.20Dec. 5, 2011
2”x4” framing at 24” O.C.
AcousticSealant
⁵⁄₈” gupsum board
Spray foam insulation atminimum depth of 3½”
Note:Wall cavity should be filled with spray foam insulation for maximum sound attenuation.
Insulthane a Division of Elastochem 37 Easton Rd Brantford, On N3P 1J4, Canada
www.Elastochem-ca.com/insulthane
Wall Section, Sealed Crawl Space with Termite Inspection Area
D1.21Dec. 5, 2011
Leave minimum 4” block exposedto allow inspection for termites
SEALEDCRAWL SPACE
CONDITIONED SPACE
Note:Closed-cell spray foam insulation thickness to meet local code requirements.
Minimum thickness of 2" (50mm) required when installed as a vapor retarder.
SealantRadiant
Floor
Spray foam insulationoptional at grade
EXTERIOR
Insulthane a Division of Elastochem 37 Easton Rd Brantford, On N3P 1J4, Canada