Top Banner
Instrumentation CTD Dissolved Oxygen Sensor ADCP/ Current Meters Oxygen Titrations Nutrient Concentrations Circulation and Chemical Tracer Distribution Physical Oceanography Chemical Oceanography
24

Instrumentation CTD Dissolved Oxygen Sensor ADCP/ Current Meters Oxygen Titrations

Feb 23, 2016

Download

Documents

jock

Circulation and Chemical Tracer Distribution Physical Oceanography Chemical Oceanography. Instrumentation CTD Dissolved Oxygen Sensor ADCP/ Current Meters Oxygen Titrations Nutrient Concentrations. Units. Temperature: °C - PowerPoint PPT Presentation
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: Instrumentation CTD Dissolved Oxygen Sensor ADCP/ Current  Meters Oxygen Titrations

Instrumentation CTD Dissolved Oxygen Sensor ADCP/ Current Meters Oxygen Titrations Nutrient Concentrations

Circulation and Chemical Tracer Distribution Physical Oceanography Chemical Oceanography

Page 2: Instrumentation CTD Dissolved Oxygen Sensor ADCP/ Current  Meters Oxygen Titrations

UnitsTemperature: °C

Salinity: no units; defined by 1978 Practical Salinity Scale (PSU)

Pressure: db (decibars)Density

Density (ρ) is a function of T, S, and pρ(4°C, 0, 1 atm) = 1 g cm-3 = 1000 kg m-3

Potential Density of Seawater (corrected for compressibility) ranges from 1022 kg m-3 to 1028 kg m-3 in the open ocean

Sigma Theta (σθ) = ρ(T, S, 1 atm) - 1000 [kg m-3]

Page 3: Instrumentation CTD Dissolved Oxygen Sensor ADCP/ Current  Meters Oxygen Titrations

We prefer concentration Units of mol/kg

Dissolved Oxygen Units??Puget Sound Scientific Literature:

mg/L, mg-at/L, mL/L, μmol/kgConversion Factors:

1 mole O2 = 32 g O2 = 22.414 L O2 = 2 g-at O

1 L seawater = 1000 cm3 = (0.001 m3)×(density of SW)

Density of SW [kg/m3] = 1000 + sigma theta

Page 4: Instrumentation CTD Dissolved Oxygen Sensor ADCP/ Current  Meters Oxygen Titrations

An estuary is...A place where river(s) meet the ocean that has surrounding land and a limited opening...

Puget Sound is an estuary; it is connected to the Pacific Ocean through the Straits of Juan de Fuca.

Coastal Plain or Drowned River Valley Estuary

Page 5: Instrumentation CTD Dissolved Oxygen Sensor ADCP/ Current  Meters Oxygen Titrations

Fjord estuaries

– Sill blocks exchange of deep water with ocean Little water movement below sill depth

Strong vertical stratification

Fig 12.35

Page 6: Instrumentation CTD Dissolved Oxygen Sensor ADCP/ Current  Meters Oxygen Titrations

Solid = SurfaceDashed =

Deep

Schematic Diagram of the Flow in Puget Sound

Estuarine Circulation:

Surface Outflow,Deep Inflow

Driven by river input,mixing, and deep water intrusions

Port Susan

Saratoga Passage

WHIDBEY BASIN

Admiralty Inlet

Page 7: Instrumentation CTD Dissolved Oxygen Sensor ADCP/ Current  Meters Oxygen Titrations
Page 8: Instrumentation CTD Dissolved Oxygen Sensor ADCP/ Current  Meters Oxygen Titrations

PROCESSES THAT CONTROL CIRCULATION:--Wind Forcing--Density Stratification

Freshwater inflow at the surface--Tides--Flushing events from the open ocean

Page 9: Instrumentation CTD Dissolved Oxygen Sensor ADCP/ Current  Meters Oxygen Titrations

Stratification

How does it change from rivers to Main Basin?How does change in stratification affect biology?

Page 10: Instrumentation CTD Dissolved Oxygen Sensor ADCP/ Current  Meters Oxygen Titrations

Measured Currents are dominated by the tides Estuarine flow revealed only when tides are

removed

Tides ≈ 5-10 × Strength of Estuarine Flow

Page 11: Instrumentation CTD Dissolved Oxygen Sensor ADCP/ Current  Meters Oxygen Titrations

Current Meter Measurements in the Main Basin -- Averaged over the interval indicated -- With the Tidal currents removed

Level of no motion?

Page 12: Instrumentation CTD Dissolved Oxygen Sensor ADCP/ Current  Meters Oxygen Titrations

Episodic Intrusions of Deep Water

Page 13: Instrumentation CTD Dissolved Oxygen Sensor ADCP/ Current  Meters Oxygen Titrations

Numerical Modeling

20 layers350-m resolution in Puget SoundRiver flow - 15 major river, USGSAtmosphere - 6-hour avg from MM5Eight tidal components

Page 14: Instrumentation CTD Dissolved Oxygen Sensor ADCP/ Current  Meters Oxygen Titrations

Water Residence Times

Box Model(1992-2001)

Numerical Model(2006)

Page 15: Instrumentation CTD Dissolved Oxygen Sensor ADCP/ Current  Meters Oxygen Titrations

Cycles of Phosphorus, Nitrogen, Carbon, Oxygen and Silica in Puget Sound waters

Tracers of Biological Production and Respiration

REDFIELD RATIOS: ∆P : ∆N : ∆C : ∆O2 1 : 16 : 106 : -153

For diatoms: NO3- : Si ratios: ∆N : ∆Si 1 : (1-3)

Page 16: Instrumentation CTD Dissolved Oxygen Sensor ADCP/ Current  Meters Oxygen Titrations

Dissolved Inorganic Phosphorus, DIP vs Dissolved Inorganic Nitrogen, DINIn the Ocean

REDFIELD STOICHIOMETRY OF LIFE: P : N : C : O2 = 1 : 16 : 106 : 153

Page 17: Instrumentation CTD Dissolved Oxygen Sensor ADCP/ Current  Meters Oxygen Titrations

Sections of Oxygen, Phosphate, and Nitrate in Whidbey Basin, Oce 220, 2010

O2 (μmol kg-1)

PO43-

(μmol kg-

1)

NO3- (μmol kg-

1)

Page 18: Instrumentation CTD Dissolved Oxygen Sensor ADCP/ Current  Meters Oxygen Titrations

Nitrate : Phosphate ratios in Port SusanCompilation from recent data (Oce 220 ,

2010)

AOU (Apparent Oxygen Utilization) = [02

sat] –[O2]

Page 19: Instrumentation CTD Dissolved Oxygen Sensor ADCP/ Current  Meters Oxygen Titrations

RATES: NET OXYGEN PRODUCTION -- PHOTOSYNTHESIS Oxygen Supersaturation in Puget Sound Surface waters Oce 220 2010

( Percent Supersaturation)

Page 20: Instrumentation CTD Dissolved Oxygen Sensor ADCP/ Current  Meters Oxygen Titrations

RATES OF NET BIOLOGICAL OXYGEN PRODUCTION = ∆O2/ ∆C (153/106) X NET CARBON PRODUCTION (NCP)

OXYGEN FLUX TO THE ATMOSPHERE ~ NET BIOLOGICAL O2 PRODUCTION FO2 = - GO2 {[O2]-[O2]sat}

{[O2]-[O2]sat}The Gas Exchange Mass Transfer Coefficient, G, is a function of wind speed

Page 21: Instrumentation CTD Dissolved Oxygen Sensor ADCP/ Current  Meters Oxygen Titrations

Rates of Respiration in Waters Below the Surface

Oxygen Utilization Rate (OUR) = Respiration Rate

= AOU / t

t = time since water was at the surface

In Whidbey Basin deep water

t = time since water came into the basin from outside

RATES: NET O2 CONSUMPTION-- RESPIRATION

Page 22: Instrumentation CTD Dissolved Oxygen Sensor ADCP/ Current  Meters Oxygen Titrations
Page 23: Instrumentation CTD Dissolved Oxygen Sensor ADCP/ Current  Meters Oxygen Titrations

Knudsen’s Equations

Water Balance:Tin + R = Tout

Salt Balance:SinTin = SoutTout

Solve for Tout:

Tout = R×Sin/[Sin - Sout]

Can add temporal variability, mixing between layers

Page 24: Instrumentation CTD Dissolved Oxygen Sensor ADCP/ Current  Meters Oxygen Titrations

Main Basin