BEFORE YOU BEGINReadthese instructions completely andcarefully.•
IMPORTANT- save these instructions for
local inspector's use.• IMPORTANT- Observe all governing
codes
and ordinances.• Note to Installer - Be sure to leave these
instructions with the customer.Note to Customer- Keepthese
instructions withyour Owner's Hanual for future reference.
• Beforethe appliance is removed from service ordiscarded,remove
the washer and dryer doors.Inspect the dryer exhaust outlet and
straightenthe outlet walls if they are bent.Service information and
the wiring diagram arelocated at the accesspanel.Do not allow
children on or in the appliance.Closesupervision of children is
necessarywhenthe appliance is used near children.Install the
appliance where the temperature isabove 50°F for satisfactory
operation of thecontrol system.
• Productfailure due to improper installation is notcoveredunder
the Warranty.
_LW_KI_I|I_I£_" RISK OF FIRE. To reduce the risk of severe
injury or death, follow all installation
instructions.Appliance installation must be performed by a
qualified installer.Install the appliance according to these
instructions and in accordancewith local codes.This appliance must
be exhausted to the outdoors.Use only 4" rigid metal ducting for
exhausting the clothes dryer to theoutdoors.DO NOT install a
clothes dryer with flexible plastic ducting materials.If flexible
metal (semi-rigid or foil-type) duct is installed, it must beUL
listed and installed in accordance with the instructions foundin
"Connecting The Dryer To House Vent" on page 8 of this
manual.Flexible venting materials are known to collapse, be easily
crushed,and trap lint. These conditions will obstruct dryer airflow
and increasethe risk of fire.Do not install or store this appliance
in any location where it could beexposed to water and or
weather.Save these instructions. (Installers: Be sure to leave
these instructionswith the customer).
NOTE: installation and service of this appliance requires
basic
mechanical and electrical skills, it is your responsibility
tocontact a qualified installer to make the electrical
connections.
TOOLS YOU WILL NEED
Slip Pliers
Phillips Screwdriver
Flat-blade Screwdriver
1/4" Nutdriver
Level
#' DFA.METALDUCT(RECOMMENDED/
MATERIALS YOU WILL NEED
#' DUCT
#' DFAFLEXBLEMETAL(SEMFREGED}
CLAMPS(2}ULLISTEDTRANSITIONDUCT
(IFNEEDED} ORPKITWXO8XlO077(INCLUDES2 ELBOWS} #' SPRING
CLAMPS(2}
%#' DIA.METAL
ELBOW
%EXHAUST SAFETY
HOOD GLASSES
#' DFA.FLEXBLEMETAL(FOELTYPE} _ 3/#'STRAENULLISTEDTRANSITIONDUCT
x,4
(iFNEEDED,} DUCTTAPE GLOVES RELIEF4"COVERPLATE(iFNEEDED/
ULRECOGNIZED
(KiTWE1M454}
APPLIANCEPOWERCORDKIT
(NOTPROVIDED/
ULRATED120/2@V,}OAWITH3
OR4PRONGS,IDENTIFYTHEPLUGTYPEASPERTHEHOUSERECEPTACLEBEFOREPURCHASINGLiNECORD,
PARTS SUPPLIED
1 Cable Tie % oo2 Rubber Washers 2 Stainer Screens/Rubber
Washers(washers may be in water hoses)
2 Washer Hoses
Printedin Mexico 233DI835PO02 31-16652-5 12-12 GE
-
Installation instructions
INSTALLATION REQUIREMENTS LOCATIONThis appliance must be
installed on firm flooring to minimizevibration during spin cycle.
Concrete flooring is best, butwood base is sufficient, provided
floor support meets FHAstandards. This appliance should not be
installed on rugs orexposed to weather.
PLUMBINGWATER PRESSURE- Must be 20 psi minimum to 120
psimaximum.WATERTEMPERATURE- Householdwater heater should be setto
deliver water at 120° to !50°F (50° to 66°C)INTHEWASHERwhen hot
wash is selected.SHUTOFFVALVES- Both hot and cold shutoffvalves
(faucets)should be supplied.DRAIN- Water may be drained into
standpipe or set tub.Discharge height MUST NOTBELESSTHAN 30
INCHES,andno more than 8 feet above the base of the washer.
Standpipemust be 1-1/2 inches minimum inside diameter and must
beopen to atmosphere.
ELECTRICAL REQUIREMENTS
CAUTION: Before plugging in washer, read the followingelectrical
requirements.
CAUTION: For personal safety, do not use an extensioncord or
adapter plug with this appliance. Do not, under anycircumstances,
cut or remove the third grounding prongfrom the power cord. Follow
national electrical codes andordinances. This appliance must be
supplied with the voltageand frequency indicated on the rating
plate (located at thetop of the dryer front panel), and connected
to an individual,properly grounded branch circuit, protected by a
30-ampcircuit breaker or time-delay fuse. If the electric
supplyprovided does not meet the above requirements, call a
licensedelectrician.
Step ! Prepare the Area and Exhaust for Installation ofAppliance
(see section !).Step 2 Check and Ensure the Existing External
Exhaust isClean (see section !) and Meets Attached
InstallationSpecifications (see section 3).Step 3 Remove the Foam
Shipping Pads (see section !).Step 4 Hove the Appliance to the
Desired Location.Step 5 Connect the Power Supply (see section
2).Step 6 Connect the External Exhaust (see section 4).Step 7 Level
Your Appliance (see section 5).Step 8 Connect to plumbing
facilities (see section 8).
Step 9 Check the Operation of the Power Supplyand Venting.Step
!0 Place the Owners Manual and the InstallationInstructions in a
Location Where They Will Be Noticed By theOwner.
For Alcove or Closet Installation, see section !0.For Bathroom
or Bedroom Installation, see section !!.For Mobile or Manufactured
Home see, section 9.For side or bottom exhaust, see section 6.
2
-
7_._c
Installation Instructions24" NOMINAL PRODUCT DIMENSIONS
51"
!9.1 "J
0ool oo " 0Water Inlets
(rear) _
,_------* 23.75" --------_
--- 43"--------€
* Dimension represents door closed including handle and
knobs.NOTE: With feet set at mid position, feet can be adjusted
+_.375".
Gas Inlet
(Rear view of appliance)
27" NOMINAL PRODUCT DIMENSIONS
52.9"
0oolo o , 0
Vent _.Q_..
_._._.. Drain outleti (rear)
p3.9"
-_----- 26.8"
4------'26.7"-----_
-- !2.5"
--47"_
Waterlnlets
(rear) 5i_°
36.5" 4.35"
__ m
",_----- 30.85"------_
* Dimension represents door closed including handle and
knobs.NOTE: With feet set at mid position, feet can be adjusted
+_575".
Gas Inlet(Rear view of appliance)
[
-
Installation InstructionsMinimum Clearance Other Than Alcove or
Closet Installation
Minimum clearance to combustible surfaces and for air opening
are: 0 in. clearance both sides and rear. Consideration mustbe
given to provide adequate clearance for installation and
service.
_-I PREPARING FOR INSTALLATIONOF NEW APPLIANCE
REMOVING LINT FROM WALL EXHAUST
OPENING• Remove and discard existing plastic or metal foil
transition duct and replace with UL listed transition duct.
WALL
/INTERNALDUCT
CHECKTHATEXHAUSTOPENING HOODDAMPEROPENS
ANDCLOSESFREELV.
TILT THE APPLIANCE
SIDEWAYS AND REMOVE
THE FOAM SHIPPING PADS
BY PULLING AT THE SIDES
AND BREAKING THEMAWAY FROM THE APPLIANCE
LEGS. BE SURE TO REMOVEALL OF THE FOAM PIECES
AROUND THE LEGS.
After the machine is in thehome, remove remainingpacking
material/carton fromwasher.
DO NOT REMOVE SHIPPINGROD AT THISTIME.
Remove styrofoam block.Remove the bag containingthe Washer hoses
and partsparts from tub. Put styrofoamblock back in tub opening
tohold tub in place during therest of installation.
Hove washer close to finalposition. Make sure there isat least a
24" clearance onright sideof washer to removeshipping bar.
PULLSHIPPINGBAR OUT USING YELLOWPLASTICHANDLE.Keepbar soit can be
reinstalled if washeris ever moved again.
Styrofoam BlocJ_
Washer hoses
and parts
III
ShippingBar
Yellow plastic handle
4
NEW HOME OR REMODELING FAUCETS/DRAI N STAN DPIPEIELECTRICAL
LOCATION
Right side ofLaundry Center.
.................. _|
Locate spigots, "drain standpipe ss" |and electrical plug | 1in
this area
!FLOOR
[] ELECTRICAL CON N ECTION IN FORMATION
A WAR N IN G -TOREDUCETHERISKOFFIRE,ELECTRICALSHOCK AND PERSONAL
INJURY:• DO NOT USE AN EXTENSION CORD OR AN
ADAPTER PLUG WITH THIS APPLIANCE.Thisdryer must be electrically
grounded in accordancewith local codes,or in the absence of local
codes, with theNational ElectricalCode,ANSI/NFPANO.70 or
CanadianElectricalCode,CSAC22.1.
ELECTRICAL REQUIREMENTSThis appliance must be connected to an
individualbranch circuit, protected by the required time-delayfuses
or circuit breakers. A four or three-wire, singlephase, 120/240V or
120/208V, 60Hz, 30 amp circuitis required. If the electric supply
does not meet theabove specifications, then call a licensed
electrician.
GROUNDING INSTRUCTIONSa. For a grounded, cord-connected
appliance:
This appliance must be grounded. In the event ofmalfunction or
breakdown, grounding will reducethe risk of electric shock by
providing a path ofleast resistance of electric current. This
appliance isequipped with a cord having an
equipment-groundingconductor and a grounding plug. The plug must
beplugged into an appropriate outlet that is properlyinstalled and
grounded in accordance with all localcodes and ordinances.
WARNING -Improper connection of theequipment-grounding conductor
can result in a risk
of electric shock. Check with e qualified electrician
or servicemen if you are in doubt us to whether the
appliance is properly grounded.
-
Installation
GROUNDING INSTRUCTIONS {Cont.}
Do not modify the plug provided with the appliance. If itwill
not fit the outlet, have a proper outlet installed by aqualified
electrician.
B.For direct-wire connected appliance:This appliance must be
connected to a grounded, metal,permanent wiring system, or an
equipment-groundingconductor must be run with the circuit
conductors andconnected to the equipment grounding terminal or
leadon the appliance.
ELECTRICAL CONNECTION LOCATION24" MODELS 27" MODELS
CONNECTING DRYER USING 3-WIRE
CONNECTIONGREEN GROUNDGROUND STRAPSCREW NOT
WIRE STRAINRELIEFBRACKET
3/4",ULRECOGNIZED
RELIEF
NEUTRAL(White) HOT
WIRE
] #i0 AWGMINIMUMCOPPERCOVER CONDUCTORSOR220/240V]ORPOWER
SUPPLYCORDKITMARKEDFORUSEWITHDRYERS&
PROVIDEDWITHCLOSEDLOOPORSPADETERMINALSWITH
3-wi re Connection UPTURNEDENDS{NOTSUPPLIED},Not for use in
Canada.DO NOTuse for Mobile Home Installations.NOTfor use on new
construction.NOTfor use on recreational vehicles.NOTfor use in
areas where local codes prohibit groundingthrough the neutral
conduction.1.Turn off the circuit breaker(s) (50 amp) or remove
the
dryer's circuit fuse at the electrical box.2. Be sure the
appliance cord is unplugged from the wall.3. Remove the power cord
cover located at the lower back.4. Install 3/4 in. UL recognized
strain relief to power cord
entry hole. Bring power cord through strain relief.
nstructions5. Connect power cord as follows:
A. Connect the 2 hot lines to the outer screws of theterminal
block (marked L1 and L2).B. Connect the neutral (white) line to the
center of theterminal block (marked N).
6. Be sure ground strap is connected to neutral (center)terminal
of block and to green ground screw on cabinetrear. Tighten all
terminal block screws (3)securely.
7. Properly secure power cord to strain relief.8. Reinstall the
cover.
_:LVV/AKI_Iil_I_: NEVER LEAVE THE
COVER OFF OF THE TERMINAL BLOCK.
CONNECTING APPLIANCE USING 4-WIRECONNECTION {MUST BE USED
FORMOBILE HONE INSTALLATION}NOTES:Since January 1,1996, the
National Electric coderequires that the new constructions utilize a
4-wireconnection to an electric dryer.
WARN ING:onlya4-conductorcordshallbeused when the appliance is
installed in a location wheregrounding through the neutral
conductor is prohibited.Grounding through the neutral is prohibited
for the newbranch-circuit installations, mobile homes,
recreationalvehicles, and areas where local codes prohibit
groundingthrough the neutral conduction.
REHOVEGROUNDSTRAPANDDISCARDKEEPGREEN
GROUNDSCREW[oF_ WIRE RELOCATEGREENGROUNDSCREW
"\_,_ HERE GREENOR
RELIEF
BRACKET
COVER
HOTWIRE
3/4",UL /_
RECOGNIZED
STRAIN RELIEF
4 #10 AWGMINiMUM COPPER
CONDUCTORSOR120/240V 30A POWER
SUPPLYCORDKIT MARKEDFORUSE
WITH DRYERS& PROVIDEDWITH
CLOSEDLOOPORSPADETERMINALS
WITH UPTURNEDENDS(NOTSUPPLIED)
1. Turn off the circuit breaker (s) (30 amp) or remove
thedryer's circuit fuse at the electrical box.
2. Be sure the appliance cord is unplugged from the
wallreceptacle.
3. Remove the power cord cover located at the lower back.4.
Remove and discard ground strap. Keep the green
ground screw for step 7.5. Install 3/4 in. UL recognized strain
relief to power cord
entry hole. Bring power cord through strain relief.
-
Installation instructions
CONNECTING APPLIANCE USING 4-WIRECONNECTION (MUST BE USED
FORMOBILE HOME INSTALLATION} (Cont.}
6. Connect power cord as follows:A. Connect the 2 hot lines to
the outer screws of theterminal block (marked L! and L2).B.Connect
the neutral (white) line to the center of theterminal block (marked
N).
7. Attach ground wire of power cord with the green groundscrew
(hole above strain relief bracket). Tighten allterminal block
screws (:3)securely.
8. Properly secure power cord to strain relief.9. Reinstall the
cover.
JLWf_KI_Iil_I_: NEVER LEAVE THE
COVER OFF OF THE TERMINAL BLOCK.
EXHAUST INFORMATION
WARNING - IN CANADAANDINTHE UNITED STATES, THE REQUIRED
EXHAUSTDUCT DIAMETER IS 4 IN (102ram). DO NOTUSE DUCT LONGER THAN
SPECIFIED IN THEEXHAUST LENGTH TABLE.Using exhaust longer than
specified length will:, Increase the drying times and the energy
cost., Reduce the dryer life., Accumulate lint, creating a
potential fire hazard.The correct exhaust installation is
YOURRESPONSIBILITY.Problems due to incorrect installation are not
covered bythe warranty.Remove and discard existing plastic or metal
foil transitionduct and replace with ULlisted transition duct.The
MAXIMUM ALLOWABLE duct length and number ofbends of the exhaust
system depends upon the type ofduct, number of turns, the type of
exhaust hood (wall cap),and all conditions noted below. The maximum
duct lengthfor rigid metal duct is shown in the following
table.
27" DRYER EXHAUST LENGTHRECOMMENDEDMAXIMUMLENGTH
Exhaust Hood Types
Recommended Use only for shortrun installations_'1DIA
.......RigidMetal
56 Feet48 Feet
40 Feet32 Feet
No, of 90 ° RigidElbows Metal
0 42 Feet1 34 Feet
2 26 Feet3 18 Feet
EXHAUST INFORMATION (cont.}24" DRYER EXHAUST LENGTH
RECOMMENDED MAXIMUM LENGTH
Exhaust Hood Tgpes
Recommended Use onlg for shortrun installations
4" DIA
_'d I_ 2 1/2"
No. of 90 ° RigidElbows Metal
0 /43 Feet 36 Feet
i 33 Feet 26 Feet2 24 Feet 16 Feet
, For every additional 90° elbow, reduce the allowable
ventsystem length by 10ft.
, Two 45° elbows will betreated likeone 90° elbow. Forthe
sideexhaust installations, add one 90° elbow to the chart.
, The total vent system length includes all the straight
portionsand elbows of the system (transition duct included).
EXHAUST SYSTEM CHECK LISTHOOD OR WALL CAP, Terminate in a manner
to prevent back drafts or entry of
birds or other wildlife., Termination should present minimal
resistance to
the exhaust air fiow and should require little or nomaintenance
to prevent clogging.
,Never install a screen in or over the exhaust duct. Thiscould
cause lint build up.
, Wall caps must be installed at least 12 in. above groundlevel
or any other obstruction with the opening pointeddown.
SEPARATIONOF TURNSFor best performance, separate all turns by at
least 4 ft.of straight duct, including distance between last turn
andexhaust hood.
TURNSOTHERTHAN 90°* One turn of 45oor less may be ignored.* Two
45oturns should be treated as one 90oturn.* Each turn over
45oshould be treated as one 90oturn.SEALING OFJOINTS. All joints
should be tight to avoid leaks. The male end of
each section of duct must point away from the dryer.* Do not
assemble the ductwork with fasteners that extend
into the duct. They will serve as a collection point for lint.,
Duct joints can be made air and moisture-tight by
wrapping the overlapped joints with duct tape., Horizontal runs
should slope down toward the outdoors
1/4 inch per footINSULATION
Duct work that runs through an unheated area or is near
airconditioning should be insulated to reduce condensationand lint
build-up.
-
Installation
[] EXHAUST CONNECTION
, WARNING - TO REDUCE THERISK OF FIRE OR PERSONAL INJURY:. This
appliance must be exhausted to the outdoors.. Use only 4" rigid
metal ducting for the home exhaust
duct., Use only 4" rigid metal or UL-listed flexible metal
(semi-rigid or foil-type) duct to connect the dryer to thehome
exhaust duct. It must be installed in accordancewith the
instructions found in "Connecting The DryerTo House Vent" on page 8
of this manual.
. Do not terminate exhaust in a chimney, a wall, a ceiling,gas
vent, crawl space, attic, under an enclosed floor,or in any other
concealed space of a building. Theaccumulated lint could create a
potential fire hazard.
, Never terminate the exhaust into a common duct witha kitchen
exhaust system. A combination of greaseand lint creates a potential
fire hazard.
, Do not use duct longer than specified in the exhaustlength
table. Longer ducts can accumulate lint,creating a potential fire
hazard.
, Never install a screen in or over the exhaust duct. Thiswill
cause lint to accumulate, creating a potential firehazard.
, Do not assemble ductwork with any fasteners thatextend into
the duct. These fasteners can accumulatelint, creating a potential
fire hazard.
, Do not obstruct incoming or exhausted air., Provideanaccessfor
inspectionandcleaningof the exhaust
system,especiallyat turns andjoints. Exhaustsystem shallbe
inspectedand cleaned at leastonce ayear.
THIS DRYER COMES READY FOR REAREXHAUSTING. IF SPACE IS LIMITED,
USETHE INSTRUCTIONS IN SECTION 6 TOEXHAUST DIRECTLY FROM THE SIDES
ORBOTTOM OF THE CABINET.
STANDARD REAR EXHAUST
Forstraight line installation,connectthe drger exhaustto the
externalexhaust hood usingduct tape orclamp.
EXTERNALDUCTOPENING
DUCTTAPEORDUCTCLAMP
4" METAL DUCTCUTTO PROPERLENGTH
DUCTTAPEORDUCTCLAMP
®
°°i ©© O
nstructionsSTANDARD REAR EXHAUST
(Vented above floor level}
AGE
NOTE: ELBOWS WILL PREVENT DUCT KINKING AND COLLAPSING
ELBOW HIGHLY
RECOMMENDED
[5]LEVELINGAND STABILIZINGYOURAPPLIANCE
FRONT-TO-BACK,
[t¢l2LEVELINGLEGS
Level and stabilizing your appliance!. Carefully move the
appliance to its final location. Gently rock
the appliance into position. It is important not to damage
therubber leveling legs when moving your appliance to its
finallocation. Damaged legs can increase appliance vibration. Itmay
be helpful to spray window cleaner on the floor to helpmove your
appliance to its final position.Note: Do not use washer cover to
lift the unit.
2. To ensure the appliance is level and solid on all four
legs,tilt the appliance forward so the rear legs are off theground.
Gently set the appliance back down to allow therear legs to self
adjust.
3. With the appliance in its final position, place a level on
topof back part of the washer lid and check it side to side,then
check front to back. Screw the front leveling legs upor down to
ensure the appliance is resting solid on all fourlegs (no rocking
or the appliance should exist), turn thelock nuts on each leg up
toward the base of the unit andsnug with a wrench.
Note: Keepthe leg extension at minimum to prevent
excessivevibration. The farther out legs are extended, the more the
unitwill vibrate.
7
-
Installation instructionsCONNECTING THE DRYERTO HOUSE
VENTRIGIDMETALTRANSITIONDUCT• For best drying performance, a rigid
metal transition duct is
recommended.• Rigid metal transitions ducts reduce the risk of
crushing and
kinking.
UL-LISTEDFLEXIBLEMETAL(SEMI-RIGID}TRANSITIONDUCT• If rigid metal
duct cannot be used,then UL-listedflexible metal
(semi-rigid)ducting can beused(KitWX08X10077).• Never install
flexiblemetal duct in walls, ceilings,floors or other
enclosedspaces.• Total length of flexible metal duct should not
exceed 8 feet
(2.4m).• For many applications, installingelbows at both the
dryer and
the wall ishighly recommended(seeillustrations).Elbowsallowthe
appliance to sit closeto the wall without kinking and orcrushingthe
transition duct, maximizingdrying performance.
• Avoid restingthe duct on sharp
objects.UL-LISTEDFLEXIBLEMETAL(FOIL-TYPE}TRANSITIONDUCT• In special
installations, it may be necessaryto connect the
dryer to the housevent using a flexible metal (foil-type)duct.A
UL-listedflexible metal (foil-type)ductmay be used
ONLYininstallations where rigid metal or flexible metal
(semi-rigid)ducting cannot be used AND where a 4" diameter can
bemaintainedthroughout the entire length of the transition
duct.
• InCanadaandthe UnitedStates,onlythe
flexiblemetal(foil-type)ductsthat complywith the "Outlinefor
ClothesDryerTransitionDuct Subject2158A"shallbe used.
• Never install flexiblemetal duct in walls, ceilings,floors or
otherenclosedspaces.
• Total length of flexible metal duct should not exceed 8
feet(2.4m).
• Avoid restingthe duct on sharp objects.• Forbest drying
performance:
1.Slideoneend of the duct overthe clothes dryer outlet
pipe.2.Securethe duct with a clamp.3.With the dryer in its
permanent position,extendthe duct to
its full length.Allow 2" of duct to overlap the exhaust
pipe.Cutoff and removeexcessduct. Keepthe duct as straight
aspossiblefor maximum airflow.
4. Securethe duct to the exhaust pipewith the other clamp.
DO
ELBOW HIGHLY
RECOMMENDED
;2
DO NOT USE
EXCESSIVE
DON'T
EXHAUST
8
-
Installation instructions
_-124" MODELS ONLY:
DRYER EXHAUST TO RIGHT, LEFT ORBOTTOM CABINET
_WARNING - BEFOREPERFORMINGTHIS EXHAUST INSTALLATION, BE SURETO
DISCONNECT THE APPLIANCE FROMITS ELECTRICAL SUPPLY. PROTECT
YOURHANDS AND ARMS FROM SHARP EDGESWHEN WORKING INSIDE THE CABINET.
BESURE TO WEAR GLOVES.
For downward venting, rotate elbowsections so that elbow points
downward
REMOVEDESIREDKNOCKOUT(ONLY1)
ADDING ELBOW AND DUCT FOREXHAUST TO LEFT OR RIGHT SIDE
OFCABINET, Rotate elbow sections so that the opening points to
the
side to which you want to vent. Preassemble 4" elbow with4"
duct. Use only 4" UL approved rigid metal for ductinginside the
dryer.
, Connect duct assembly to the internal elbow.
WAR NING- Sesurenottopullordamagetheelectrical wires inside the
dryer when inserting the duct,
4" UL approved rigid metal
i DUCT
........ i..[ j ...... TAPE
, Apply duct tape as shown on the joint between the
dryerinternal duct and the straight duct pipe.
AWARNING-Internal duct joints must be
_ ecured with tope, otherwisethey may separate and causea safety
hazard.
27" MODELS ONLY:
DRYER EXHAUST TO RIGHT, LEFT ORBOTTOM CABINET
THIS EXHAUST INSTALLATION, BE SURETO DISCONNECT THE APPLIANCE
FROM
ITS ELECTRICAL SUPPLY. PROTECT YOURHANDS AND ARMS FROM SHARP
EDGESWHEN WORKING INSIDE THE CABINET. BESURE TO WEAR GLOVES.
For downward venting, rotate elbow
sections so_
EXHAUST TO LEFT OR RIGHT SIDE OFCABINET, Rotate elbow sections
so that the opening points to the
side to which you want to vent. Preassemble 4" elbow with4"
duct. Use only 4" UL approved rigid metal for ductinginside the
dryer.
* Connect duct assembly to the internal elbow.
,_ WAR NING- Besure not to pull or damage theelectrical wires
inside the dryer when inserting the duct.
, Apply duct tape as shown on the joint between the
dryerinternal duct and the straight duct pipe.
AWARNING-
H Internal duct joints must besecured with tope, otherwisethey
may separate and causea safety hazard.
-
Installation
If]PLUMBING INFORMATION
WATER SUPPLY REQUIREMENTS
. HOTAND COLDWATERFAUCETS- Must be within 42" of
the appliance water inlet hose connections. The faucetsmust be
3/4" garden hose-type so inlet hoses can beconnected.
. WATERPRESSURE- Must be between !0 and 120 poundsper square
inch with a maximum unbalance pressure,hot vs. cold flowing, of !0
pounds per square inch.
. WATERTEMPERATURE- Water heater should be set todeliver !20°F
(50°C) in the washer when HOT wash isselected.
, SHUT-OFFVALVES- Both hot and cold water shut-off
valves (faucets) should be supplied.. LOCATION- Do not install
appliance in an area where the
temperature will fall below freezing. If appliance is storedor
transported in freezing temperatures, be sure all waterfrom the
fill and drain systems has been removed.
DRAIN REQUIREMENTS
. DRAIN RATE- The drain or standpipe must be capableof accepting
a discharge at the rate of 16 gallons perminute.
, DRAINHEIGHT- The drain height must be 33" minimumand 96"
maximum.
. STANDPIPEDIAMETER- The standpipe diameter mustbe 1-1/2"
minimum. There MUST be an air gap aroundthe drain hose in the
standpipe. A snug fit can cause asiphoning action.
, SIPHONBREAKKIT- For a drain facility lessthan 33" high,the
hose, coupling and clamps provided in the machinemust be used and,
in addition, a siphon break MUST beinstalled on the back of the
machine. Use Siphon BreakKit WH49X228 and follow instructions in
the kit.
Instructions[8-1CONNECTING TO PLUMBING FACILITIES
Ifnot installed,install rubberwasher in oneendof hot water
hose.Thread hot water hose onto connection labeled H at top rearof
washer. Hand tighten, plus an additional 1/8 turn with pliers.
If not installed, install rubber washer in one end of cold
waterhose.Thread cold water hose onto connection labeled C at
toprear of washer. Hand tighten, plus an additional 1/8 turn
withpliers.
Moveappliance as closeto final location aspossible,leaving
roomfor you to make water, drain, electrical and vent connections
toyour home.
NOTE: If longer drain hoseis required, order drain hoseextension
kit, part numberWH49X301.Connect additionaldrain hose (contained in
kit)tooriginal hose with hose clamp(contained in kit).
Insert free endof drain hose intodrain opening of your home upto
drain hose stopper (do notremovehose stopper it preventssiphoning).
If water valves anddrain are built into wall, fastendrain hose to
one of waterhoses with cable tie provided(ribbed side on inside).
If yourdrain isa standpipe,fasten drainhose to standpipe with cable
tieprovided.
10
-
Installation instructions
[_]MOBILE OR MANUFACTURED HOME
INSTALLATION. Installation MUSTconform to the
MANUFACTUREDHOME
CONSTRUCTION& SAFETYSTANDARD,TITLE 24, PART32-80 or, when
such standard is not applicable, withAMERICAN NATIONAL STANDARD FOR
MOBILE HOME,ANSl/NFPA NO. 501B.
. The appliance MUST be vented to the outdoors withthe
termination securely fastened to the mobile homestructure,
. The vent MUST NOT be terminated beneath a mobile
ormanufactured home.
. The vent duct material MUST BEMETAL.• KIT14-D346-33
MUSTbeusedto attach the appliance securely
to the structure.
• The vent MUSTNOTbe connected to any other duct, vent,
orchimney.
. Do not use sheet metal screws or other fastening deviceswhich
extend into the interior of the exhaust vent.
. See section 2 for electrical connection information.
[i-0-IALCOVE OR CLOSET INSTALLATION
. If your appliance is approved for installation in an alcoveor
closet, it will be stated on a label on the applianceback.
. TO PREVENTLARGEAMOUNTSOF LINTAND MOISTUREFROMACCUMULATINGANDTO
MAINTAINDRYINGEFFICIENCY,THIS MACHINEMUSTBEEXHAUSTEDOUTDOORS.
. Do not install this appliance with lessthan the
minimumclearances shown above.
CONSIDERATION MUST BE GIVEN TO PROVIDE
ADEQUATE CLEARANCES FOR INSTALLATION AND
SERVICE.
AWARNING: DoNOTINSTALLTHISAPPLIANCE IN A CLOSETWITH A SOLID
DOOR.
DOOR VENTILATION OPENING (27" MODELS)
A minimum of 120 square inches of opening, equally dividedat top
and bottom, is required. Air openings are required tobe
unobstructed when a door is installed. A Iouvered doorwith
equivalent air openings for the full length of the dooris
acceptable.When louvers or registers are placed in door openings,
thefree air openings of the louvers or registers must equal
120square inches.
DOOR VENTILATION OPENING (24" MODELS)
27" Model
I Sq. In.
/_0 /
li: Iit qnA minimum of 72 square inches of opening is required.
Airopenings are required to be unobstructed when a door
isinstalled. A Iouvered door with equivalent air openings forthe
full length of the door is acceptable.When louvers or registers are
placed in door openings, thefree air openings of the louvers or
registers must equal 72square inches.
24,,Model__ Sqln
/Ill ', _Sq .In.
[n7BATHROOM OR BEDROOM INSTALLATION
. The appliance MUST be vented to the outdoors.
SeeEXHAUSTINFORMATION section 3 & 4.
, The installation must conform with local codes or, in
theabsence of local codes, with the NATIONAL
ELECTRICALCODE,ANSI/NFPA NO. 70.
11
-
Installation instructions
[] SERVICING
,WARNING- LABEL ALL WIRES PRIOR TO DISCONNECTION WHEN
SERVICINGCONTROLS. WIRING ERRORS CAN CAUSE IMPROPER AND DANGEROUS
OPERATION
AFTER SERVICING/INSTALLATION.
For replacement parts and other information, refer to Owner's
Manual for servicing phone numbers.
REGISTERYOUR NEW APPLIANCE TO RECEIVEANYIIvlPORTANT PRODUCT
NOTIFICATIONS.
Please go to www.GEAppliances.com or mail in yourProduct
Registration Card.
For questions on installation, call: 800.626.2000
(US)or800-56!-3344 (Canada).
12
-
InstructionsD'Installation
Laveuse/S cheuse
Electriques Unifi s
Question sur l'instellotion? Appelez eu 800.561.3344 (Canada)Ou
visitez notre site web: www.electromenogersge.co
AVANT DE COMMENCERLisezles instructions compl_tement et
ovecattention.
•11'4PORTANT- Gardezcesinstructions pouruneutilisation
possiblepar un r@arateur local.
• IMPORTANT- Respectez les normesenvigueur et ordonnances.
• Note pour I'instoltoteur - Assurez-vous delaisserces
instructionsavec leclient.
• Note pour le client - Gardezces instructionsavec votre manuel
d'utilisation et d'entretienpour uneconsultationfuture
possible.
•Avant que I'appareil soit d@lac_ apresr_paration ou pour _tre
jet_, enlevezles portesdela laveuseet de las_cheuse.
• Contr61ezlessortiesd'_chappementet
redressezI'installationsurlemur si elleest tordue.
• Lesinformationsder@aration et lediagrammedesconduits sont
situ_ssur le tableau d'acces.
• Emp_chez les enfants d'etre sur ou donsI'appareil.Une
supervision proche des
enfantsestn_cessaireIorsqueI'appareilestutilis_.
• tnstallez I'appareil oO la temp@ature est en-dessous de 50°F
pour un fonctionnementsatisfaisantdu systemede contr61e.
•Toute d6faillance de I'appareil suite _ uneinstallation
incorrecte n'est pas couverte parla garantie.
AVERTISSEMENT - RIESQUED'INCENDIE• Pourr_duireJesrisquesde
biessuresgrovesou de mort, suivezJesinstructionsd'instaitation.
•L'installationdeI'appareildolt
_trefaiteparunepersonnequalifi@.
•InstalJezJ'appareilsetoncesinstructionset conform_mentaux
normesJocales.
•Cettes@heusedolt avoirunsystemed'@happementversJ'ext@ieur.
•Utilisezseulementdes conduitsrigidesen m@talde 4" pour
Jacanatisationde Jas_cheuseversl'ext_rieur.
•NEPASinstallerunes@cheuseavecdesconduitsflexiblesenplastique.Silesconduitsflexiblesde
m@tal(semi-rigideou en aluminium)sont install@s,ils doivent@treULet
install@sconform@mentaux instructionstrouv@sdans deJapage8
decemanuet.Lesmat@iauxdesconduitsflexiblessont connuspour se
fendre,s'@cras@set @tredespi@ges6 peluches.Cesconditionsferont
obstacleaufluxd'air de las@cheuseet augmenterontles
risquesd'incendie.
•N'instaltezpas et n'entreposezpascet appareitdansun endroit
oOil pourrait@treexpos@_ I'eauouau climat.
•Gardezlesinstructions.(l'installateurdolts'assurerdelaissercesinstructionschezleclient).
NOTE: L'installation et la r_paration de cet appareil exigent
desconnaissonces basics en m_canique et en _lectrique. C'est
votre
responsebilit_ de contocter un instelloteur quolifi_ pour loire
lesconnexions _lectriques.
OUTILS A UTILISER
Pince
Tourne-vis Croix
Tourne-visPlat
Tourne-vis A Douille 1A"
Niveau
TUYAUEN METALDE DIAM 4"RECOMMENDE)
TUYAU FLEXIBLEEN METALSEMI RIGIDE)UL DE DIAM
4" (SI NECESSAIRE)KITWXO8X!O077 (2 COUDESINCLUS)
2 PINCESDETUYAU4" OU 2 PINCESTENDEUR4"
MATERIAL NECESSAIRE
55COUDE DE METALDE DIAM/4"
ROULEAUADHESIFPOURTUYAU
CAPUCHOND'ECHAPPEMENT
5/4" REDUCTEUR
(_ GANTS DE TENSION(UL RECONNUE)TUYAU FLEXIBLEEN
METALSEMIRIGIDE) ULDEDIAM4" CACHE DE(SI NECESSAIRE)
PROTECTION(SI
NECESSAIRE)DE 4" LUNETTES(KITWE1M454) DE SECURITE
CORDON ELECTRtQUED'ALtM ENTATtON (NON
tNCLUT)CONVERStON UL!20/240V, ]0 ° AVEC ]
OU 4 DENTS. tDENTtFtEZLE TYPE DE PRISE TELQUE LE RECEPTACLE
DE LA MAISON L'EXtGEAVANT D'ACHETER LES
FtLS ELECTR!QUES.
PIECES FOURNISES
__ 2 Rondellesen Rondelles en! collier en _,,,,_-,.,4_j_
Caoutchouc caoutchoucplastique "__ (les joints peuvent entre
2 tuyaux de dans les tuyaux a eau)la laveuse
233D'183£PO02 3J-J6652-£ J2-J2 GE
-
Instructions d'Installation
CONDITIONS D'INSTALLATION DEL'EMPLACEMENT
Cet appareil doit @reinstall6 sur un sol solide pour
minimiserlesvibrations durant le cycle d'essorage. Lesol en b6ton
estmeilleur, mais une base en bois est sufFisante.Cet
appareilnedevrait pas 6tre install6 sur untapis ou expos6 au
climat.
PLOMBERIE
PRESSIONDE L'EAU- Elledolt 6tre de 20 psi minimum et120 psi
maximum.
TEMPERATUREDE L'EAU- le chauffe-eau de votre maison
dolt 6tre configur6 pour distribuer une eau de 120o5 !50°F(50° 6
66o Ct DANS LA LAVEUSEIorsque I'eau chaude ests61ectionn6e.
VALVESDE FERIVlETURE- La valve de fermeture d'eaufroide et celle
d'eau chaude (robinet) doivent _tre fournies.DRAINAGE- L'eau peut
_tre drain6e par le tuyau de rejet 61'6goutou par le bac configur6.
La hauteur de I'_coulementNEDOlTPASETREINFERIEUREA 30 POUCES,et pas
plus de8 pieds audessus de la base de la laveuse. Letuyau de
reject6 I'_gout doit mesurer !-!/2 pouce minimum 6 I'int6rieur
dudiam@treet doit @treouverte vers I'ext@ieur.
CONDITIONS ELECTRIOUES
PRUDENCE: Avant de brancher la laveuse, lisez lesconditions
@lectriquessuivantes.
PRUDENCE: pour votre propre s6curit6, n'utilisez pasde rallonge
ou d'adaptateur avec cet appareil. Ne coupezpas ni enlevez la
troisi@me dent de la prise 61ectriquecorrespondant 6 la masse.
Suivez les normes 61ectriquesnationales pour le voltage et la
fr6quence indiqu6ssur la plaque de conversion (situ6e au-dessus de
las6cheuse sur le tableau avant), et branchez 6 une
priseindividuelle,correctement connect6e 6 la terre, prot6g6epar
disjoncteur de 30-amp ou un fusible 6 retardement.Si I'installation
61ectrique ne r@ond pas aux conditionsci-dessus, appelez un
61ectricien qualifi6.
Etape
Etape
Etape
EtapeEtape
i Pr@parezla Zone et I'Echappement deI'installation de
I'Appareil (voir section 1).2 V@ifiez et Assurez I'Echappement
Existant Externequ'il soit Propre (voir section !) et les
Sp6cificationsd'lnstallation Ci-jointes (voir section 3).3
Enlevezla Mousse de Rembourrage de Transport(voir section 1).
4 D6placez I'appareil au Lieu D6sir6.5 Branchez I'appareil au
Courant Electrique (voirsection 2).
Etape 6 Branchez I'Echappement Externe (voir section 4).Etape 7
Nivelez I'appareil (voir section 5).Etape 8 Raccordez au syst_me de
plomberie (voir section 8)
Etape 9 V@ifiez le Fonctionnement du Courant Electriqueet la
Ventilation.
Etape !0 Placez le Manuel de I'Utilisateur et lesInstructions
d'lnstallation dans un Lieu O_ IIs
Seront Trouv6s Par le Propri6taire.
Pour le Renfoncement ou I'lnstallation dans un iVleuble,voir
section 10.
Pour I'installation dans une salle de bain ou unechambre, voir
section !1.
Pour I'installation dans un mobile home, voir section 9.Pour
1'6chappement de cot6 ou artiste, voir section 6.
2
-
Instructions d'Installation
.5'
51"
0°400 ° 0
!9.! ''j
* Dimensions Iorsque los portes sont ferm_es incluont los
poign_es et los boutons.NOTE: Dimensions en pieds, correspondont 5
+_375".
Entr#e du gazVue de I'orri#re de I'opporeil)
2.75"
)U
DIMENSiONES NOMINALES DU PRODUIT 27"
O_1 o o ° O
Ventilation ,____
___..
Sortie drainage
__ urri_re
_-- 3.9"
_---- 26.8"
Arriv_e d'eau
_------'26.7"----_
--47"_
Entr#e du gaz
Vue de I'orri_re de I'opporeil)
3"
* Dimensions Iorsque les pores sont ferm_es incluent les
poign_es et les boutons
NOTE: Dimensions en pieds, correspondont 5 +_375".
3
-
Instructions d'InstollotionEspace Minimum Autre Que le
Renfoncement ou l'installation Dons un Meuble
L'espace minimum pour les surfaces combustibles et I'ouverture
d'air sont: 0 in. d'espace de chuque cot6 et c_I'arri@e. Les
consid@ations doivent @re donn6es pour fournir un espace ad6quat
pour I'installation et la r6paration.
[_]SE PREPARER POUR L'INSTALLATIOND'UN NOUVEL APPAREIL
ENLEVER LES PELUCHES DE L'OUVERTURED'ECHAPPEMENT DU MUR
• Enlevez et d_berrussez-vous des feuilles de m@ulet de
plustique du tuyeu de transition et remplucez-le uvecun tuyuu de
transition UL.
MMUR
VERIFIEZQUE LACLEHAPPEMMENT
OUVRE ETFERMELIBREMENT
PENCHER L'UNITE VERS
LE COTE ET ENLEVER
LES PROTECTIONS
DE TRANSPORT DE
STYROMOUSSE EN LESBRISANT VERS L'EXTERIEUR
DES PATTESDE L'UNITE.
S'ASSURER D'ENLEVER
TOUS LES MORCEAUX DE
STYROMOUSSE AUTOURS
DES PATTES.
OUVERTUREINTERNEDUTUYAU
Btocde mousseApr@sque la machine soitdans votre de
potvstvr@ne_maison,enlevezles mat@iauxrestantset cartonsde la
laveuse.
N'ENLEVEZPASLESBARRESDETRANSPORTPOURLEMMOMMENT.
Enlevezleblocdemoussedepolystyrene. Tuyauxde_ _,Enlevezle sac
contenant les Tuyauxde jonction et._. Jjonction et les pi@cesdu
bac. IViettezle pi@ces IIbloc de mousse de potystyr@nedans
III'ouverture du bac pour tenir le bac enplace durant le reste de
I'instaltation.D6placez la laveuse vers la position .finale.
Assurez-vousqu'it y ait au mains I I24" d'espace 6 droite de la
laveusepourenlevertesbarres de
transport.TIREZLESBARRESDETRANSPORTVERSL'EXTERIEURUTILISANTLA
POtGNEEJAUNEENPLASTIq)UE.Gardezlesbarres _aucas oOvousdevriez la
r@instalt@ou sila laveus est d@plac@eplus tard.
transport "Poign6ejauneen plastique
NOUVELLEMAISON ET ROBINETSREMODELES/ LETUYAU DE VIDANGEA
L'EGOUT/EMPLACEMENTELECTRIQUtj" Cot6 droit du
centre de lavage
Localisez le robinet, la .......... |
colonne d'alimentation i"du drainage et la prise
61ectrique de cette zoneI
T42"
sot -
2-]INFORMATION SUR LE BRANCHEMENT
ELECTRIQUE
AVERTISSEMENT- POURREDUIRE LES RISQUES D'INCENDIE,DE DECHARGE
ELECTRIQUE ET DEBLESSURE PERSONNELLE:, N'UTILISEZ PAS DE RALONGE
ELECTRIQUE OU
D'ADAPTATEUR AVEC CET APPAREIL.
Cet appareil dolt _tre branch6 c_la terre conform6mentaux normes
locales et ordonnances, ou dans I'absence
de normes locales, conform_ment AUX NORMESELECTRIQUES
NATIONALES, ANSI/NFPA NO. 70, ou LaNorme 61ectrique canadienne CSA
C22.1.
CONDITIONS ELECTRIQUESCet opporeil dolt @tre branch@ 6 une prise
_lectriqueindividueile, prot@g_e per un fusible retordoteur ouun
disjoncteur. T@trophos_ ou triphos_, uniphos_,120/240V ou 120/208V,
60Hz, circuit de 30 amp estrequis. Si I'instollotion _lectrique ne
r_pond pos ouxsp@cifications ci-dessus, alors appelez un
_lectricienquolifi@.
INSTRUCTIONS DE MASSEA.Pour une mise 6 la terre, de
1'61ectrom6nager
connect@s 6 I'aide d'un cordon:
Cet appareil dolt @tre mis 6 la terre. En cas ded6faillance ou
de panne, la terre r6duira le risque dechoc 61ectrique en
fournissant un chemin de moindrer6sistance du courant @lectrique.
Cet appareil est6quip6 d'un cordon comportant un conducteur deterre
et une fiche de terre. La fiche dolt @tre branch6e
dans une prise appropri@e, correctement install@e etmise en
conformit6 avec tousles codes Iocaux une
des ordonnances.
AVERTISSEMENT - Unemouvoiseconnexion du conducteur de terre peut
entroTner unrisque de choc @lectrique. Consultez un @lectricien
ouun r@poroteur quolifi@ si vous @tes dons le doute quont
4
-
Instructions d'Installation
INSTRUCTIONS DE MASSE (suite)
Ne pas modifier la fiche fournie avec I'appareil - sielle
n'entre pas dans la prise, faites installer une prisead6quate par
un 61ectricien qualifi&
B.Pour des appareils aux ills connect@sdirectement:Cet appareil
dolt _tre reli6 6 une masse m6tallique,syst@mede cablage permanent
ou un conducteur deterre dolt _tre ex_cut6 avec les conducteurs du
circuitet connect_ 6 la borne de mise 6 la terre ou de plombsur
I'appareil.
EMPLACEMENT CONNEXION I_LECTRIOUEPRODUIT 24" PRODUIT27"
BOITIER DE
TERMINAL
BRANCHER L'APPAREIL EN UTILISANTUNE CONNEXION TRIPHASEE
SI NECESSAIRE, SELON LES VJSVERTEDENORMES LOCALES, INSTALLEZ
[vJiSEA FiXATiONUNE PRISE A LA TERRE LATERREEXTERNE(NONINCLUT)A
UNE
MASSEENMETAL,UN TUYAU FIL CROCHETD'EAU FROIDE OU AUTRES _b
SERRECABLEMASSES DETERMINEES PAR
L'ELECTRICIEN QUALIFIE. _
SERRECABLERECONNU3/j' UL
NEUTRE(Blanc) FIL
PROTECTION3#
10AWGMINIMUMCONDUCTEURSDECUIVREOU120/240V30ACORDON
ETFOURNITAVECUNEBOUCLEFERMEEOUDESBORNESDEBASEAVECDESEXTREMITESRETOURNEES(PASINCLUT),
Connexion a 3 ills
Ne peut pas #tre utilis#e au Canada.Ne peut pas #tre utilis#e
dans une maison mobile.Ne peut pas #tre utilis#e dans les nouvelles
constructions.Ne peut pas #tre utilis#e dans les v#hicules
r@cr#atifs.Ne peut pas @treutilis#edans les r#gionsDOlescodes
locauxinterdisent la raise 6 la terre par le biais du
cSbleneutre.
1. Eteignez le disjoncteur (30 amp) ou d6placez le fusibledu
circuit de la s@cheuseau boitier @lectrique.
2. Assurez-vous que le cordon @lectrique de I'appareilsoit
d@branch@du boitier du mur.
3. Enlevez la protection du cordon @lectrique situ@eaudos en
bas.
4. Installez le serre-c@ble UL sA in. A I'entr@edu
cordon@lectrique. Amenez le cordon @lectrique par leserrec@ble.
5. Branchez le cordon 61ectrique de la mani@e
suivante:A.Branchez 2 ills electriques au vis aux extr@mit@sdu
boitier de terminal (marqu@eL1 et L2).B.Branchez la ligne neutre
(blanche) au centre du bloc
de terminal (marqu@eN).6. Assurez-vous que le fil de la masse
est branch@ au
terminal neutre du boitier et 6 la vis verte de mise 6laterre
sur I'arri@redu coffrage. Serrez toutes les visdesboitiers de
terminaux (3)fermement.
7. Assurezla connexion du cordon @lectriqueau serrecable.8.
R@installezle couvercle.
,_ AVERTISSEMENT: NE
JAMAIS LAISSER LE BOITIER DETERMINAL SANS LE COUVERCLE.
BRANCHER L'APPAREIL EN UTILISANTUNE CONNEXION TETRAPHASEE
(DOLTETRE UTILISEE POUR L'INSTALLATIONDANS LES MOBILES HOMES)
NOTES: Depuis le premierjanvier 1996, la norme
NationaleElectrique exige que les nouveaux appareils utilisent
une
connexion tetraphas#e pour une s#cheuse #lectrique.
AVERTISSEMENT: Seulement lescordons _lectriques tetraphas_s
doivent @tre utilis_slorsqu'un appareil est install_ dans un lieu
ou la massepassant par un circuit neutre est prohib_e.
Lesinstallations des embranchements de circuit_lectrique, les
mobiles homes, les v_hicules r_cr_atifs,et les zones o_ les normes
locales prohibent lebranchement 6 la masse par un circuit
neutre.
CHAUD DEPLACEZLAVISVERTEDEMISEALATERREICI
FILVERTOUJAUNE
SERRECABLE
PROTECTION
SERRECABLE /_
HO RECONNUsA"UL
4 # iO AWG HINIMUP CONDUCTEURS
DE CUIVRE OU 120/240V 30A CORDON
ELECTRIOUE, KIT MARQUE POUR UTILiSATION
AVEC SECHEUSES ET FOURNIT AVEC UNE
BOUCLE FERHEE OU DES BORNES DE BASE
AVEC DES EXTREHITES RETOURNEES (PAS INCLUT)
1. Eteignez le disjoncteur (30 amp) ou d_placez le fusibledu
circuit de la s#cheuse au boitier #lectrique.
2. Assurez-vous que le cordon #lectrique de I'appareil
soitd6branch6 du boitier du mur.
3. Enlevez la protection du cordon #lectrique situ#e audos en
bas.
4. Enlevez et d_barrassez-vous des tresses de masse.Gardez la
vis verte de mise 6 la terre pour I'#tape 7.
5. Installez le serre-c@ble UL sA in. A I'entr#e du
cordon#lectrique. Amenez lecordon _lectrique par leserrec@ble.
6. Branchez le cordon #lectrique de la mani@e
suivante:A.Branchez 2 ills electriques au vis aux extr#mit@s
duboitier de terminal (marquee L1 et L2).B.Branchez la ligne
neutre (blanche) au centre du bloc
de terminal (marqu#e N).
5
-
Instructions d'Installation
BRANCHER L'APPAREIL EN UTILISANTUNE CONNEXION TETRAPHASEE
(DOITETRE UTILISEE POUR L'INSTALLATIONDANS LES MOBILES HOMES}
{suite}
7.Attachez le fil de la masse du cordon 61ectrique 6la vis verte
de mise 0 la terre (trou au-dessus despinces du serre-c_blet.
Serrez toutes les vis desboitiers de terminaux 13tfermement.
8.Assurez la connexion du cordon 61ectrique auserrec_ble.
9. RGinstallez le couvercle.
AVERTISSEMENT: NE
JAMAIS LAISSER LE BOITIER DETERMINAL SANS LE COUVERCLE.
[] INFORMATION D'ECHAPPEMENT
24" LONGUEUR D'ECHAPPEMENT
LONGUEUR MAXIMUM RECOIVilViANDEE
Types de Capuchons d'echappement
Utilise seulement pour les
Installations de petites distancesRECOMMANDEE:
.......I .......M@al rigide
4S FeetSS Feet24 Feet
Node coude M@al rigidec_9000 36 Feet1 26 Feet2 26 Feet
• Pour chaque coude additionnelde 90°, r@duirede !0 pieds
laIongueurtotalepermisedusyst@medeventilation.
•Deuxcoudesde4S° devront@treconsid@r@scommeun
coudede90°.Pourlaventilationlat@ale,ajouteruncoudede90°autableau.
•La Iongueurtotale du syst@mede ventilation inclut toutes
lesportions droites et tousles coudes du syst@me(le tuyau
detransitioninclus).
AVERTISSEMENT - AUCANADAETAU× USA, LE DIAMETRE DU
TUYAUD'ECHAPPEMENT REQUISEST 4" (102turn).N'UTILISEZ PAS DE TUYAU
PLUS GRAND QUELA TAILLE SPEClFIEE DANS LE TABLEAU DELONGUEUR
D'ECHAPPEMENT.En utilisant un tuyua d'Gchappement plus grand que
laIongueur spGcifiGe,cela:• Augmentera le temps de sGchage et les
d@enses en6nergie.
RGduira la durGede vie de la s_cheuse.
Accumulera les peluches, crGant un risque
potentield'incendie.L'installation correcte d'_chappement est
VOTRERESPONSABILITE.Les probl@mesdus _ une installationincorrecte
ne sont pus couverts par la gerantie.Enlevez et d@barrassez-vous
des plastiques existantsou du tuyau de transition en feuilles de
mGtal etremplacez-le par un tuyau de transition UL.La Iongueur de
tuyau MAXIMUM AUTORISEEet lehombre de coudes du
syst@med'@chappementdGpend du type de tuyau, du nombre de courbes,
dutype du capuchon d'Gchappement (bouchon du mur)et des conditions
prGsent@esci-dessous.. La Iongueurmaximum du tuyau pour les tuyaux
nglde en m_tal estmontr@edans le tableau cidessous.
27" LONGUEUR D'ECHAPPEMENT
LONGUEUR MAXIMUM RECOMMANDEE
Types de Capuchons d'echappement
RECOM MAN DEE Utilise seuiement pour lesInstallations de petites
distances
,__
4" DIA.
I...... 2-1/2"
NOde Coudes M@aJrigide M@al rigide6 900
0 56 Feet 42 Feeti 48 Feet 34 Feet2 40 Feet 26 Feet
3 32 Feet 18 Feet
LISTE DE CONTROLE DU SYSTEMED'ECHAPPEMENTCAPUCHON OU GRILLEDU
MUR, Prot#gez la sortie de votre canalisation dans le but
d'#viter les appels d'air ou I'entr#e d'un oiseau et
autresanimaux sauvages.Cette protection devrait prGsenter une
r#sistanceminimum au flux d'air #chappement et devrait exigerpeu ou
pas de maintenance pour #viter I'encrassement.
, Ne Jamais installez d'#cran dans ou sur le tuyaud'#chappement.
Ceci pourrait conduire 6 la cr#ationde peluches.Les grilles du mur
doivent _tre install#es au moinsB12 in. Au-dessus du niveau du sol
ou 6 cette distanceau-dessus de n'importe quel autre objet pouvant
faireobstruction 6 cette sortie.
SI_PARATIONDE TOURS
Pour une meilleure performance, sGparez touslescoudesd'au moins
4 ft. De tuyauterie droite, incluantla distance entre le dernier
coude et le capuchon dusyst_me d'#chappement.
COUDESAUTRESQUE 90°, Un coude de 450 ou mains peut _tre ignor#.,
Deux coudes de 450 devraient _tre trait#s comme uncoude de 90°.
, Chaque coude de plus de 450 devrait _tre trait# commeun coude
de 90°.
SCELLAGEDESJOINTS, Tousles joints devraient @tre serr#s pour
#viter lesfuites. L'extr#mit_ male de chaque section de tuyau
dolt_tre dirig#e vers I'ext@ieur de la s#cheuse.
, N'assemblez pas la canalisation avec des agrafes quientrent
dans le tuyau. Elles serviront B la cr#ation depeluches.
, Les joints de tuyaux peuvent _tre faits d'air et demoisissures
en emballant le chevauchement de jointsavec le rouleau adh_sif de
tuyau.
Les trajets horizontaux devraient descendre versI'ext@ieur de
!/4 pouce par pied.
ISOLEMENTLacanalisation qui court 5 travers une zone non
chauff@eou qui est pros de I'air conditionn_ devrait _tre
isol_epour r_duire la condensation et la creation de peluches.
6
-
Instructions d'Installation
i-4--IBRANCHEMENT DE L'ECHAPPEMENT
AVERTISSEMENT- POURREDUIRE LES RISQUES D'INCENDIE OU DEBLESSURES
PERSONNELLES:. Cet appareil doit avoir un syst@med'6chappement
vers I'ext@ieur., Utilisez seulement de la tuyauterie rigide en
m6tal
de 4" pour le tuyau d'6chappement de la maison., Utilisez
seulement un tuyau rigide en m@talou un
tuyau flexible UL (semi-rigide ou en aluminium)pourbrancher la
s6cheuse au tuyau d'6chappement dela maison. II dolt @tre install6
conform6ment auxinstructions trouv@ en page 7 de ce manuel
sous"Brancher La S6cheuse au Conduit d'A@ation de lamaison'.
, Ne mettez pas fin @ 1'6chappement par unechemin6e, un mur, un
toit, un conduit de gaz, un petitespace, un grenier, sous un
plancher non ferm6, oudans n'importe quel autre espace dissimul@de
votrebatiment. La charpie accumul6e pourrait cr6er undanger
potentiel d'incendie.
, Ne jamais mettre fin @1'6chappement par un tuyaucommun avec le
syst@me d'6chappement de lacuisine. Une combinaison de graisses et
de peluchescr6er un risque potentiel d'incendie.N'utilisez pas de
tuyau plus grand que cequi est sp6cifi6 dans le tableau de
grandeurd'@chappement. Des tuyaux plus grands peuventpermettre
I'accumulation de peluches et cr6er unrisque d'incendie
potentiel.Ne jamais installer un 6cran dans ou sur le
tuyaud'@chappement. Ceci causera I'accumulation depeluches, cr6ant
un risque potentiel d'incendie.N'assemblez pas la canalisation avec
des agrafesqui entrent dans le tuyau. Ces agrafes peuventcr66s
I'accumulation de peluches, cr6ant un risqued'incendie
potentiel.N'obstruez pas Fair entrant et sortant.Mettez
@disposition un acc@s pour inspecter etnettoyer le
syst@med'@chappement, sp@cialementaux coudes et auxjoints.
Lesyst@med'@chappementdevrait @tre inspect6 et nettoy6 au mains une
loispar an.
L'ECHAPPEMENT ARRIERE FAIT PARTIE DE CETTE
SECHEUSE. Sl VOTRE ESPACE EST LIMITE, UTILISEZLES INSTRUCTIONS
DE LA SECTION 9 POUR AVOIRUN SYSTEME D'ECHAPPEMENT LATERAL OU PAR
LEBAS DU COFFRAGE DE LA MACHINE.
Pourune installationen lignedroite,branchez
lesyst_med'@chappementde la s6cheuseau
conduitexterned'6chappementen utilisant du scotchou une pince.
OUVERTURE EXTERNE
DU CONDUIT
APPROPRIEE SCOTCH DE
TUYAU OU PINCE
TUYAU EN HETAL 4" COUPEA LA LONGUEUR
SCOTCH DE TUYAU
OU PINCE
ECHAPPEMENT ARRIERE STANDARD(Ventil_ au-dessous du niveau du
sol)
CONFIGURATION
RECOMMANDEEPOUR MINIMISER _[[[j _
IILES BLOCAGE DECANALISATION
COUDE HAUTEMENT
RECOIVilViANDE
7
NOTE: LES COUDES EFIPECHERONT LES NOEUDS ET LES
EFFONDREFIENTS
DU CONDUIT.
[] METTRE A NIVEAU ET STABILISER
VOTRE APPAREIL
/ JTRE
NIVEAU DE
L'AVANTA
L'ARRIERE
dPIEDSDE NIV_LEMENT
Mettre _ niveau et stabiliser votre appareil1.
D@lacezprudemmentI'appareilverssa positionfinale.Balancez
avecdouceurI'appareilen position,tl est importantde ne
pasendommagerles pieds de nivelementen
caoutchoucIorsquevousd@lacezvotre appareilvers sa
positionfinale.Les piedsendommag@speuventaugmenterlesvibrationsde
I'appareil.tlpeut@treutilede pulv@iserun nettoyeurde vitresur
[email protected]:N'utilisezpaslaprotectiondela
laveusepourporter I'unitd.
2. PourassurerqueI'appareilest5 niveauet
stablesursesquatrepieds,inclinezI'appareilvers I'avantpourque
lespiedsarrieresoient bars du sol. Redescendezen douceur I'appareil
pourpermettreaux piedsarri@esdes'ajusterontseuls.
3. Ayant I'appareil 5 sa position finale, placez un niveau
au-dessus au fond du couvercle de la laveuse et v@ifiez dechaque
cot@,puis v@ifiezI'avant et I'[email protected] piedsde
nivelementavant pour assurerque I'appareilrestestablesur sesquatre
pieds (nebalancezpas I'appareilpour v@ifiersa
stabilit@),relevezles@crousdeverrou surchaque piedversla basede
I'unit@et assurezavec untourne-5-gauche.Note:
Gardez/'extensiondepied au minimum pour dviter
/esvibrationsexcessives.Plus/espiedssont agrandis,plus I'unitda
dechancedevibrer.
7
-
Instructions d'Instollotion
BRANCHER LA SECHEUSE AL'AERATION DE LA MAISONTUYAU RIGIDE
DETRANSITION EN METAL
• Pour les meilleures performances de s_chage possibles, le
tuyau de transition rigide en m@tales trecommand@.
• Les tuyaux de transition rigides en m@tal r@duisent le
risqued'@crasement et de noeuds.
TUYAU DETRANSITION UL FLEXIBLEEN METAL(SEMI-RIGIDE}
• Si le tuyau rigide en m6tal ne peut pas_tre utitis@,alors le
tuyau ULflexibleen m@al(semi-rigide)peut
@treutilis6(KitWX08X!0077).
• Nejamais installerde tuyau flexibleenm@alau
murs,auplafond,auxsob ou autres espacesferm_s.
• La Iongueurdu tuyau flexibleenm@alne @wait pasexc6d68
pieds(2,4m).
• Pourplusieursapplications,installer descoudes 6 lafois6 la
s6cheuseet au mur est fortement recommand6 (voir illustration
ci-dessous).
Lescoudes permettent 6 I'appareitd'etre ptac6 pros du mur
sansfaire de noeudset/ou _craser le tuyau de transition, maximisant
lesperformancesde s@chage.
• Evitezde pauserle tuyau dur desobjets coupants.LE TUYAU DE
TRANSITION UL FLEXIBLE EN METAL
(ALUMINIUMI
• Pour des installations sp@ciales, il peut @tre n@cessaire
debrancher la s@cheuse6 I'a@ation de la maison utilisant un
tuyau flexible en m@tal (aluminium). Un tuyau UL flexibleen
m@tal (semi-rigide) ne peut pas@tre utilis@ET ceci o0 undiam_tre de
4" peut @tremaintenu tout au long du tuyau.
,, Au Canada et aux USA, seulement lestuyaux flexiblesen
m@tal(aluminium) qui se plient 6 devrait @treutilis@.
,, Nejamais installer de tuyau flexible en m@talsur lesmurs,
lesplafonds, les sob ou autres espaces ferm@s.
,, La Iongueur du tuyau flexible en m@talne devrait pasexc@d@e8
pieds (2,4m).
,, Evitez de pauser le tuyau dur des objets coupants.• Pour les
meilleures performances possibles:
!. Fakes glisser une extr@mit@du tuyau sur le conduit ext@ieurde
la s@cheusede v@tements.
2. Fixez le tuyau avec une pince.3. Ayant la s@cheuseclans sa
position permanente, prolongez
le tuyau vers sa Iongueur maximum. Laissez 2" de tuyause
chevaucher avec le conduit d'@chappement. Coupez etenlevez I'exc_s
de tuyau. Gardez le tuyau aussi droit quepossible pour maximiser le
flux d'air.
/4.Fixez le tuyau au conduit d'@chappement avec I'autre
pince.
AIRE
UDESFORTEIVlENTRECOIVllVlANDES
# L'APPAREILSUR LE
ROP LONG f_L_,_--------_ _J_
I l\ /"'NEPAs ,\
\ bV _,// \ CONTRELE\/
8
-
Instructions d'Installation
E_ _UEMENT POUR MODELES DE 24 PO
ECHAPPEMENT DE LA SECHEUSE PAR
LA DROITE, PAR LA GAUCHE OU PARLE HAUT DE COFFRAGE
AVERTISSEMENT- AVANTDEREALISER L'INSTALLATION DE
L'ECHAPPEMENT,ASSUREZ-VOUSDE DEBRANCHERLA SECHEUSE
DEL'ALIMENTATIONELECTRIQUE.PROTEGEZVOSMAINS ET VOS BRAS DES
PARTIESCOUPANTES
LORSQUEVOUSTRAVAILLEZDANSLECOFFRAGE.ASSUREZVOUSDE
PORTERDESGANTS.
Pour une a@ation vers le bas, faites pivoter les sections
ducoude pour que ce m@mecoude penche vers le bas.
DEPLACEZ LESCACHESDESIRES(SEULEMENT)
_TAGE
AJOUTER LE COUDE ET LE TUYAU POURL'ECHAPPEMENT PAR LA GAUCHE OU
PAR LADROITE DU COFFRAGE, Pour la canalisation de cot@, enlevez le
cache
(SEULEMENT1). Faites pivoter les sections du coudeafin qu'il
soit dans la direction d6sir@e. Pr@arezI'assemblagedu coude de 4"
avec le tuyau de4". Utilisez seulement le tuyau UL rigide en
m@alapprouv6 pour la canalisation de la s_cheuse.
, Ins@ez I'assemblage du tuyau par I'ouverture etbranchez le
coude interne.
A
AAVERTISSEM ENT- Assurez-vous de nepas tirer ou endommager les
ills _lectriques 6 l'int_rieurde Ia s_cheuse lorsque vous ins_rez
le tuyau.
ruyau rigide UL en m@al autoris6 de 4"
SCOTCH A TUYAU
Appliquez le rouleau adh6sif comme il est montr6 surlejoint
entre le tuyau interne de la s6cheuseet le conduit.
II
AVERTISSEMENT-Les joints du tuyau internedoivent _tre bien
attaches avecdu scotch, sinon ils pourraientse s_parer ou causer un
risquepour la s_curit_ des personneset de la machine.
JNN__UEHENTPOUR HODELES DE 27 PO
ECHAPPEHENT DE LA SECHEUSE PAR LA DROITE,PAR LA GAUCHE OU PAR LE
HAUT DE COFFRAGE
AVERTISSEM ENT- AVANT DEREALISER L'INSTALLATION DE
L'ECHAPPEMENT,ASSUREZ-VOUS DE DEBRANCHER LA SECHEUSE
DE L'ALIMENTATION ELECTRIOUE. PROTEGEZ VOSMAINS ET VOS BRAS
DESPARTIES COUPANTES
LORSOUE VOUS TRAVAILLEZ DANS LE COFFRAGEASSUREZVOUS DE PORTER
DES GANTS.
Pour une a6ration vers le bas, faites pivoter lessections du
coude pour que ce m_me coude)enche vers le bas.
AJOUTER LE COUDE ETLE TUYAU POUL'ECHAPPEMENT PAR LA GAUCHE OU
PAR LADROITE DY COFFRAGE, Faites pivoter les sections du coude afin
qu'il penche vers
le c6t6 que vous desirez a@er. Faites pivoter les sectionsdu
coude afin qu'il soit dans ladirection d@sir_e.Pr@parezI'assemblage
du coude de 4" avec le tuyau de 4". Utilisezseulement le tuyau UL
rigide en m6tal approuv6 pour lacanalisation de la
s_cheuse.Connectez I'assemblage de tuyau au coude interne.
AVERTISSEMENT-Assurez-vous de ne p.as tirer ouendommager les
ills electriques 6I'int6rieur de la s6cheuse Iorsquevous ins_rez le
tuyau.
, Appliquez le rouleau adh6sifcomme il est montr6 sur le
joint entre le tyuyau interne dela s6cheuse et le conduit.
11 AVERTISSEMENT-Lesjoints du tuyau interne doivent6tre bien
attaches avecdu scotch,sinon ils pourraient se s_parer oucauser un
risque pour la s_curit_des personnes et de la machine.
9
-
Instructions d'Installation
[-7-11NFORMATIONSUR LA PLOMBERIE
CONDITIONS DE UAPPROVISIONEMENT
EN EAU
, ROBINETS D'EAU CHAUDE ET FROIDE - IIs doivent_tre 6 moins de
42" des branchements de I'appareilpour I'arriv6e d'eau. Les
robinets doivent _tre 3A"dela tuyauterie du jardin afin que les
tuyaux internespuissent _tre branch6s.
, PRESSIONDE L'EAU- Elle dolt _tre entre 10 et 120psiavec un
maximum de pression d_s6quilibr6e, unfluxd'eau chaude et un flux
d'eau froide, de 10 psi.TEMPERATUREDE L'EAU - Le chauffe-eau
devrait _treconfigur6 pour distribuer une eau de 120°F(50°C)(_ la
laveuse Iorsque I'option de lavage CHAUD ests_lectionn6e.VALVESDE
FERMETURE- Les valves de fermetured'eauchaude et d'eau froide
devraient _tre fournies.EMPLACEMENT-N'installez pas I'appareil dans
une zoneo_ la temp@ature sera en-dessous de [email protected] I'appareilest
gard6 ou transport6 avec des temp@atures en-dessous de z@o,
assurez-vous que toute I'eau depuisle remplissage jusqu'au syst_me
de drainage a 6t6enlev_e.
CONDITIONS DE DRAINAGE
, RAPPORTDE DRAINAGE- Le drainage et le tuyau derejet (_ 1'6gout
doivent _tre capable d'accepter un6coulement d'un rapport de !6
gallons par minute.TAILLEDU DRAINAGE- La taille du drainage doit
_tre de33" minimum et de 96"
maximum.DIAMETREDUTUYAUDEREJETAL'EGOUT- Lediam_tre
du tuyau de rejet (_1'6goutdoit _tre de 1-1/4"minimum.II DOlT y
avoir un espace d'air autour duconduit dedrainage dans le tuyau de
rejet (_1'6gout. Une coupurepeut causer un effet de siphon.KIT
BRISE-SIPHON- Pour une installation dedrainageinferieure (_33" de
hauteur, le tuyau, la connexion etles pinces fournies dans
I'appareil doivent _tre utilis6set, de plus, un brise-siphon DOlT
_tre install6 au dosde la machine. Utilisez le Kit
Brise-SiphonWH49X228 etsuivez les instructions du kit.
TBRANCHER LA PLOMBERIE
Installez si n6cessaire lesjoints en caoutchouc (_I'extr6mit6de
I'arriv@ed'eau chaude sur la machine. Introduisez le tuyaud'eau sur
le branchement marqu@de la lettre H dans lecoinen hautde la
machine. Serrez6 la main, et ajouter 1/8 detouravec unepince.
Installez si n6cessaire lesjoints en caoutchouc (_I'extr6mit6de
I'arriv@ed'eau froide sur la machine. Introduisez le tuyaud'eau sur
le branchement marqu@de la lettre C dans le coinen hautde la
machine. Serrez6 la main, et ajouter 1/8 detouravec unepince.
D6placez I'appareil au plus proche de sa potion finale
sipossible,laissant de la place pour que vous puissiez faire
lesbranchements d'eau, dedrainage, @lectriqueet deventilationdans
votre maison.
NOTE: Si un conduit dedrainage plus grand est requis,commandez
le kit d'extensiondeconduitdedrainage,num@rode produit
WH49X301.
Branchezunconduitadditionnelde drainage (inclut dans le kit)au
conduit original avec despincesde conduit (inclutdans
lekit).lnc@ezuntuyau devidange6 la canalisation de drainagede votre
maison pour fermerle tuyau de drainage (ne pasassurer
I'@tanch@it@destuyauxpour 6viter de cr6er un effet desiphon),fii
lesvalves d'eau et ledrainage construit dans lemur,attachez le
tuyau de drainage61'undes tuyaux d'eau avec lecollier en plastique
inclut (fix6face 6 face). Sivotre drainageest un tuyau de rejet
61'6gout,attachez le tuyau de drainageaut uyau de rejet
61'6goutavecun collier en plastique inclut.
10
-
Instructions d'Installation
F9]INSTALLATION POUR LESMOBILES
HOMES• L'installation DOIT _tre conforme aux STANDARDS DE
CONSTRUCTIONET DESECURITEDU MOBILE HOME, TITRE24, PARTIE 32-80
ou, Iorsque de tels standards ne sontpas applicables, il faut alors
consid_rer LES STANDARDSNATIONAUX AMERICAINS POUR LES MOBILES
HOMES,ANSI/NFPA NO. 501B.
• L'appareil DOlT 6tre ventil6 vers I'ext6rieur avec une
sorties_curis_e fix_e c3la structure du mobile home.
• La ventilation NE DOlT PASsortir par le dessous du
mobilehome.
• Le materiel du conduit d'a_ration DOlT ETREDE METAL.
• Kit 14-D346-33 doit _tre utilis_ pour attacher la s_cheuse
c_la structure de faqon s_curitaire.
• La ventilation NE DOlT PAS _tre connect_e c_aucun autre
conduit d'_vacuation des gaz brOl_s ou c_une chemin_e.•
N'utilisez pus de vis c_t61eou autres fixations quis'entendent
c3I'int_rieur de la ventilation.
• Voir section 12 au sujet de I'information concernant
lesbranchements _lectriques.
[To-]ALCOVE OR CLOSET INSTALLATION
__0" _ "
• Sivotre uppureil est autons_ pour une installation
dansunemplacement ou un meuble, cela sera indiqu_ sur laplaqueau
dos de I'appareil.
• POUR EVtTER UN GRAND NOMBRE DE PELUCHESETD'HUMtDtTE CAUSES PAR
L'ACCUMULATtON ET POUR
MAtNTENIR L'EFFtCACtTEDE SECHAGE, CETTE MACHINEDOlT AVOtR UN
SYSTEME D'ECHAPPEMENT VERSL'EXTERIEUR.
• N'installez pas cet appareil s'il vous manqueI'espaceminimum
tel qu'il est montr_ ci-dessus.
UNE ATTENTION PARTICULIERE DOlT ETREPRISE
POUR ASSURER DES ESPACES ADEQUATS POURL'INSTALLATION ET LA
REPARATION.
AVERTISSEMENT- .'I.STALLEZPASCETAPPAREIL DANS UN MEUBLE AYANT
UNE PORTE.
VENTILATION DE L'OUVERTURE
DEPORTE (MODELES 27"}Un minimum de 120Sq. In.d'ouverture,divis66
part 6gale enhaut eten bos, est requis.Lesouvertures d'oir sont
tenues d'etre d_gog_esIorsqu'uneporte est install_e.Une porte
persienneavecd'ouverturesd'oir 6quivolentessur toute Io Iongueurde
Io porte est acceptable.
27" Model HaiH H 60Sq'ln"
Lorsque les persiennes ou les gonds sont plac6s sur les
ouvertures de laporte, les ouvertures d'air des persiennes ou des
gonds dolt @tre_gole 6120 Sq, In.
VENTILATION DE L'OUVERTURE
DEPORTE (MODELES 24"}Un minimum de 72 Sq. In. d'ouverture est
requis. Les
ouvertures d'oir sont tenues d'etre d6gog6es Iorsqu'une
porte est instoll6e. Une porte persienne avec des
ouvertures d'oir 6quivolentes sur toute Io Iongueur de Io
porte est acceptable.
II ?! 24 Sq. In.
Lorsque les persiennes ou les gonds sont ploc6s dons
lesouvertures de Io porte, les ouvertures d'oir des persiennesou
des gonds doivent _tre _gole 6 72 sq. in.
In]INSTALLATION POUR SALLE DE BAIN OU
CHAMBRE
o
o
L'appareil DOlT _tre ventil_ vers I'ext_rieur. Voir
INFORMATIOND'ECHAPPEMENTdes sections 3 & 4.
L'installation dolt _tre conforme aux names locales
ou,dansI'absence de ces normes locales, aux NORMES NATIONALES
ELECTRIQUES,ANSI/NFPA NO. 70.
11
-
Instructions d'Installation
iT21REPARATION
AVERTISSEMENT - HARQUEZ TOUS LES FILS AVANT LE
DEBRANCHEMENTLORSQUE VOUS EFFECTUEZ UN CONTROLE POUR REPARATION.
LES ERREURS DE
BRANCHEMENT PEUVENT CAUSEES DES PROBLEMES DE FONCTIONEMENT
APRES
REPARATION ET D'INSTALLATION.Pour les pisces de rechc]nge et
(]utres informc]tions, veuillez reporter (]u Manuel de
I'Utilisc]teur pour les num#ros de
t#l#phone du service c]pr_s vente.
ENREGISTREZVOTRE NOUVEL APPAREIL POUR OUEVOUS RECEVIEZDES
INFORiVlATIONS IIPORTANTES
SUR LE PRODUIT.
Allez, SVP,sur notre site www.GEAppliances.com ou
envoyez par la poste votre Carte d'inscription du produit
Pour des questions sur I'instc]llc]tion, composez:800.626.2000
(E.U.)ou 800.56!.334/4 (Cc_nodo)
12
-
Instrucciones deInstalaci6n
Secadora Unificada aLavadora/EI6ctrico
i Preguntas sabre la Instalaci6n? Llame al: 1-800-GECARES
(US)
0 visite nuestro sitio web en: www.GEAppliances.com (US)
ANTES DE COMENZARLea estas instrucciones en su totalidad
yatentamente.. IM PORTANTE- Conserve estas
instrucciones para usa del inspector local.. IMPORTANTE- cumpla
con todos los
c6digos y ordenanzas gubernamentales.. Nota para el
Instalador-AsegOrese de que
el comprador conserve estas instrucciones.. Nota para el
Consumidor - Guardeestas
instrucciones en el manual clelusuario parafuturas
consultas.
. Antes de dejar este electrodom6stico fuerade servicio o de
cleshacerse clel mismo,quite la puerta de la lavacloray la
secaclora.
. Inspeccione la salida clel escape de lasecaclora y ajuste la
conexi6n a los salidasde pared si se encuentran inclinadas.
. Lo informaci6n clel servicio y el diagramade cableado se
encuentran ubicados en elpanel de acceso.
. No permita que haya niflos sabre niclentro del
electrodom6stico. Cuanclo elelectrodom6stico se use cerca de
niflos,ser6 necesariosupervisarlos de cerca.
. Instale la secaclora clonde la temperaturasupere los 50°F
(10°C), para unfuncionamiento satisfactorio clelsistema decontrol
de la secaclora.
. Lo garant[a no cubre las fallas clel procluctodebido a una
instalaci6n incorrecta.
ADVERTENCIA: RIESGO DE INCENDIO
• Afin dereducirel riesgodelesionesgraveso
lamuerte,sigatodaslasinstruccionesdeinstalaci6n.
• Lainstalaci6ndeelectrodom@sticosdebeser realizadaparun
instaladorcalificado.. Instale el electrodom6stico de acuerdo con
estas instrucciones y de
acuerdo con los c6digos locales.. Esteelectrodom6stico
deber(_contar con un escape hacia el exterior.•
Uses61ounconductodemetalridigode4"paraqueelelectrodom@sticocuenteconunasalidaalexterion
•
NOinstaleunasecadoraderopaconmaterialesdeconductopl6sticoflexible.Siseinstalaun
conductode metal flexible(semi-figidoo tipo
hojadealuminio),deber6figurarenla
listadeULyserinstaladodeacuerdoconlasinstruccionesquefiguranen
"Conexi6nde la Secadoraa la Ventilaci6nde la Casa"en la p6gina8 de
estemanual.Sesabequelosmaterialesflexiblesparaventilaci6ncolapsan,se
rompencon facilidad,y atrapan
laspelusas.Estascondicionesobstruir6nel flujo
deairedelasecadoraeincrementar6nel riesgodeincendio.
• No instaleni guardeesteelectrodom@sticoen
ningunaubicaci6ndondepudieraencontrarseexpuestoal aguay/o
losfactoresclim@icos.
• Guardeestasinstrucciones.(Instaladores:AsegLirensede
queestasinstruccionesIleguena manosdelcomprador).
NOTA: Para realizar la instalaci6n y el servicio t6cnico de
este
electrodom_stico se requiere contar con una capacitaci6n
mec6nica y el_ctrica b6sica. Es su responsabilidad
comunicarse
con un instalador calificado para realizar las cone×lanes
el6ctricas.
HERRAMIENTAS
QUE NECESITARA
Pinza con junta deslizante
Destornillador Phillips
Destornilladordecabezaplana
Llave para Turcas de 1/4
Nivel
)CONDUCTO DE METALDE 4" DE DIAMETRORECOMENDADO)
CONDUCTO DETRANSICIONDE METALFLEXIBLE(SEMI-R[GIDO)DE 4" DE LA
LISTADE UL(SI ESNECESARIO)KITWXO8X]_O077(INCLUYE2CODOS)
CONDUCTO DETRANSICIONDE METALFLEXIBLE(TIPOHOJA DEALUMINIO de
4"DE LA LISTADE UL(SI ESNECESARIO)
MATERIALES NECESARIOS
%CODO METALICO
ABRAZADERASPARA DE4" DECONDUCTO DE 4"
DIAMETRO(x2)OABRAZADERASPARARESORTEDE4" (×2)
PARACINTA DECONDUCTO
CAMPANADE ESCAPE
{_} AMORTIGUADORCON REFUERZODE 3/4" LISTADO
_ GUANTES POR UL
PANELPROTECTOR _m----_//'_(:_/1DE4" (SI ESNECESARIO)(KIT GAFAS
DEWE1M454) SEGURIDAD
KIT DEL CABLE DECORRIENTE DEL
ELECTRODOMESTtCO(NO PROVtSTO)
120/240V, 30A DE 5 0 4PATAS LtSTADO POR UL.
tDENTtFtQUE EL TtPODE CABLE DE ACUERDOCON EL RECEPTACULODE LA
CASA ANTES DE
ADQUtRtR EL CABLEDE tNSTALACtON
ELECTRICA.
PIEZAS PROVISTAS _.4_
i Enlace de Cables __2 Mangueras de Desag0epara Lavadora
% oo2 Arandelas de 2 Pantallas deCaucho Filtro/Arandelas
de Caucho(las arandelas podr6n estar enmangueras de agua)
233DI835PO02 31-16652-5 12-12 GE
-
Instruccionesde Instalaci6n
REQUISITOS DE INSTALACI6N UBICACI6NEsteelectrodom6stico se debe
instalar en un piso firme a finde minimizar la vibraci6n durante el
ciclo de centrifugado.Se recomiendan los pisos de concreto, pero
una base demadera es suficiente, siempre que dicho piso cumpla
conlos est6ndares de FHA. Esteelectrodom6stico no se deber6
instalar sobre tapetes ni estar expuesto la interperie.
PLOMERIA
PRESIONDELAGUA- Debe set de un m[nimo de 20 psiy unm6ximo de 120
psi PRESIONDELAGUA - El calentador deagua del hogar deber6 estar
configurado para que el aguaest6 entre 120° y 150°F(50°y 66°0
ENLALAVADORAcuandose seleccione lavado caliente.VALVULASDE CIERRE-
Tantola vdlvula de cierre de agua caliente como la de agua
fr[a(grifos) deber6n ser suministradas.DRENAJE- Elagua podr6ser
drenada al tubo de subida o el tubo configurado. Laalturade
descarga NO DEBERASERINFERIORA 30 PULGADAS,ono m6s de 8 pies sobre
la base de la lavadora. El tubo desubida debe serde un m[nimo de
1-!/2 pulgadas dentro deldi6metro y deber6 estar abierto a la
atm6sfera.
REQUiSITOS ELECTRICOS
PRECAUCI6N: Antes de enchufar en el agua, lea ysiga los
requisitos el6ctricos.
PRECAUCI6N" Para su seguridad personal, nouse extensiones ni
enchufes adaptadores con esteelectrodom6stico. Nunca, bajo ninguna
circunstancia,corte ni elimine el tercer cable (tierra)del cable de
corriente.Cumpla con los c6digos y ordenanzas nacionales
deelectricidad. Este electrodom6stico deber6 ser provistocon el
voltaje y la frecuencia indicados en la placa deespecificaciones
(ubicada en la parte superior del panelfrontal de la lavadora), y
estar conectado a un circuitoindividual que est@adecuadamente
conectado a tierra,protegido por un disyuntor ofusible de retardo
de30 amp. Sielsuministro el6ctrico provisto no cumple con los
requisitosanteriores, Ilame a un electricista calificado.
Paso i Prepare el Area y el Escape para la Instalaci6n
delElectrodom6stico (consulte la secci6n !)
Paso 2 Controle y AsegOrese de que el Escape ExternoExistente
est6 Limpio (consulte la secci6n !) y queCumpla con las
Especificaciones de Instalaci6nAdjuntas (consulte la secci6n
:3).
Paso 13 Retire las Almohadillas de Gomaespuma deTransporte
(consulte la secci6n !)
Paso 4 Mueva la Secadora a la Ubicaci6n Deseada.Paso 5 Conecte
el Cable de Corriente (consulte la secci6n 2).Paso 6 Conecte el
Escape Externo (consulte la secci6n 4).Paso 7 Nivele el
Electrodom6stico (consulte la secci6n 5).Paso 8 Conecte alas
instalaciones de plomer[a (consulte la
secci6n 8).
Paso 9 Controle el Funcionamiento del Cable de Corrientey la
Ventilaci6n.
Paso !0 Coloque el Manual del Propietario y lasInstrucciones de
Instalaci6n en una Ubicaci6nDonde el Propietario las Pueda
Encontrar.
Para instalaciones en alcobas o cl6sets consulte lasecci6n
!0.Para instalaciones en baBos o habitaciones consulte lasecci6n
!!.Para Casas Prefabricadas o Casas M6viles consulte lasecci6n
9.Para una salida lateral o inferior, consulte la secci6n 6.
2
-
Instruccionesde Instalaci6n
DIMENSiONES NOMINALES DEL PRODUCTO DE 24"
1..5 ¸
5!"
0°4 oo . 0
Ventilaci6n __._--
_Salida dedrenaje-"?- .... (trasera)
i'_--- 4.2"
f,----- 23.75" ------_
Entradas de agua
(trasera)
.2 I,
37" A
L32:
'_---'23.75"---_
43"'--_
s1°¢X
-
Instruccionesde Instalaci6n
Claros Minimos para Instalaci6n que no Sea Alcoba o CI6setLos
claros minimos pare superficies combustibles y el aire libre son: 0
pulgadas de despeje a ambos lados y en la parte
trasera. Se debar6 considerar qua se debe de contar con las
claros adecuados para la instalaci6n y el servicio t6cnico.
mPREPARACI6N PARA LA INSTALACI6NDE UN ELECTRODOMI_STICO
NUEVO
ELIMINACI6N DE PELUSAS DE LA
ABERTURA DE ESCAPE DE LA PARED• Retire y elimine pl6sticos u
hojas de aluminio
existentes en el conducto de transici6n y reemplacepar el
conducto de transici6n nuevo que figura en lalista de UL
ABERTURAINTERNA DELCONDUCTO
j/PARED
CONTROLE0UE ELDE LA
CAMPANA DE EXCAPESEABRAY SECIERRELIBREMENTE.
INCLINE ELELECTRODOM ESTICO
HACIA AMMOS LADOS Y
RETIRE LAS ALMOHADILLAS
DE GOMAESPUMA DEL
EMBALAJE, EMPUJANDO
DE UN LADO A OTRO Y
RETIRANDO LAS MISMAS
DE LAS PATASDELELECTRODOM ESTICO.
ASEGURESE DE q)UITAR
TODAS LAS PIEZAS DE
GOMAESPU MA ALREDEDOR
DE LAS PATAS.
Unavezque lam6quinaest_enet hogar,retire ei material/cart6n de
embalajerestantede la lavadora.NO RETIRE A0N LA VARILLA
DEEMBAROUE.
Retireelbloquedegomaespuma.RetiredeIrecipiente la
balsaquacontiene lasmangueras y plazas de la Lavadora.Cotoque et
bloque de gomaespumanuevamente en la abertura
delrecipienteparesostenerelmismoensulugar durante et testa de la
instalaci6n.
Mueva la lavadora hasta su ubicaci6nfinal. Aseg0rese de qua haya
par Iomenos 24" de espacio sabre el ladoderecho de la lavadora para
retirarla varilla de embarque. EMPUJELA VARtLLA DE EMBAROUE
HACIAAFUERA USANDO LA MANIJA DEPLASTICOAIVlARtLLA.Mantenga
lavarilla de modo qua se pueda volvera instalar si la lavadora se
volviera amover nuevamente.
btBLOq)UEDEGOIVlAESPUIVlA
IVlANGUERASY PtEZASDG LA LAVADORA
IVARILLADEEMBARq)UE
IVlANtJA DE PLASTtCO
AlVlARILLA
GRIFOS DE HOGAR NUEVOS O REMODELADOS/
TUBO VERTICAL DE DRENAJE/UBICACI6N
ELECTRICA _ Lado derecho delcentro de lavado
"_-12" -'_
Ubique las Ilaves, tuba
vertical de drenaje yenchufe el6ctrico en
esta 6rea.!
T
FLOOR
[_]INFORMACI6N SOBRE LA CONEXIONELECTRIC_
,ADVERTENCIA -PARAREDUCIREL RIESGO DE INCENDIO,
DESCARGAELECTRICA V LESIONES PERSONALES:, NO USE EXTENSIONES NI
ENCHUFES ADAPTADORES
CON ESTE ELECTRODOM#STICO.
La secadora deber6 ester correctamente conectada
a tierra de acuerdo con los c6digos y ordenanzaslocales, o en
ausencia de c6digos locales, de acuerdocon el CODI60 NACIONAL DE
ELECTRICIDAD(NATIONAL
ELECTRICAL CODE), ANSI/NFPA NO. 70 o El C6digoCanadiense de
Electricidad.
REQUISITOS ELI_CTRICOSEste producto se deber6 conectar a un
circuito derivadoindividual, protegido par disyuntores o fusibles
de retardode tiempo adecuadoso Se requiere un circuito de cuatroo
tres cables de fase simple de 120/ 240V o 120/ 208V,60 Hz, 30
amperioso Si el suministro eJ_ctrico provisto nocumple con los
requisitos anteriores, Jlame a un electricistacaJificado.
INSTRUCCIONES DE CONE×I6N A TIERRAA.Conexi6n a tierra, aparato
conexi6n par cable: Este
aparato debe ester conectado a tierra. En un posible
malfuncionamiento o averia, la conexi6n a tierra puede reducirel
riesgo de descarga el6ctrica al proporcionar una via demanor
resistencia de la corriente el6ctrica. Este aparatoest6 equipado
con un cable qua tiene un conductorde puesta a tierra y un enchufe
de conexi6n a tierra. Elenchufe debe conectarse a un tomacorriente
adecuado
que est6 debidamente instalado y conectado a tierra deacuerdo
con todos los c6digos locales un ordenanzas.
ADVERTENCIA- una conexi6ninadecuada de la conexi6n a tierra
puede resulteren un riesgo de descarge el_ctrice. Consulte e
unelectricista celificedo si tiene dudas sabre si el eparatoest6
correctamente conectado a tierre.
4
-
Instruccionesde Instalaci6n
INSTRUCCIONES DE CONEXI6N A
TIERRA (cont.)No modifique el conector provisto con el aparato -
siel conector no encaja en el tomacorriente, solicite aun
electricista calificado que instale un tomacorrienteadecuado.
B.Para electrodom6sticos con conexi6n directa par
hilos:Esteuparuto debe estar conectado a un metal a tierra,sistema
de cubleado permanente, oun conductor atierra de equipo se debe
ejecutar con los conductoresdel circuito y conectado al terminal de
tierra del equipoo al cable del artefacto.
UBICACI6N DE CONEXI6N ELI_CTRICAPRODUCTODE 24" PRODUCTODE
27"
BLOQUE DETERMINALES
CONE×ION DE LA SECADORA USANDO
UNA CONE×I6N DE 3 CABLESTORNILLO CINTADEVERDEO,E
CONEXIONCONEXIONATERRAATIERRA
CABLEDE SOPORTEDELCARGA AMORTIGUADOR
CONREFUERZO
AMORTIGUADORCONREFUERZODE3/4'LiSTADOPORUL
NEUTRO(Blanco)
TAPA
CARGA
CABLESELECTRICOSCONDUCTORESDECOBRENUN,i0 AWGDEPORLOMENOS] HEOS0
KiTDECABLEDECORRIENTEDE120/240V]OAMARCADOPARAUSOCONSECADORASYPROVBTOCONTERNINALESDEBUCLE
Conexi6n de 3 cablesNO usar en Canada.NO usar en instalaciones
en casas m6viles.NO usar en casas nuevas.NO usar en veh[culos
recreativos.
NO usar en areas donde los c6digos locales proh[benla connexi6n
el6ctrica a tierra par el media del cableneutral.1 Apague el
disyuntor(es)(30 amperios) o retire el fusibledel circuito de la
secadora de la caja de electricidad.2. AsegOrese de que el cable de
la secadora est6desenchufado del recept6culo de la pared.3. Retire
la tapa del cable de corriente ubicada en la parteinferior
trasera.4. Instale el amortiguador con refuerzo de 3A
pulgadaslistado par UL del agujero de entrada del cable
decorriente. Pase el cable de corriente par el amortiguadorcon
refuerzo.
5. Conecte del cable de corriente del siguiente modo:A. Conecte
los 2 polos de corga a los tornillosexteriores del bloque terminal
(marcados L1y L2).B. Conecte el polo neutral (blanco) al centro
delbloque terminal (marcado N).
6. AsegOrese de que la cinta de conexi6n a tierra est6conectada
a la terminal del centro neutral del bloque yal tornillo verde de
conexi6n a tierra en la parte traseradel gabinete. Ajuste todos los
tornillos (:3)del bloque determinales firmemente.
7. Asegureelcable de corrienteal amortiguador con refuerzo.8.
Vuelva a instalar la tapa.
ADVERTENCIA: NUNCADEJE LA TAPA FUERA DELBLOQUE DE
TERMINALES.
CONE×I6N DEL ELECTRODoOMI_STICOUTILIZANDO UNA CONE×ION DE
4CABLES {SE DEBERA USAR PARA LAINSTALACION EN VIVIENDAS
M6VILES).NOTAS:Desde el i de enero de 1996, el C6digo Nacional
deElectricidad requiereq uelasconstrucciones nuevas utilicenuna
conexi6n de 4 cables para una secadora el6ctrica.
A ADVERTENCIA: saose usar6 uncable de 4 conductores cuando el
electradom@stico seinstale en una ubicaci6n donde se prohiba la
cone×i6na tierre a trev_s del conductor neutral. Se prohibela
cone×i6n a tierra a trav@s del conector neutralen vehiculos nuevos
y en 6reas donde los c6digoslocales prohiben la cone×i6n a tierra a
trav@s de unaconducci6n neutral.
AMORTIGUADORCONREFUERZO
TAPA
AMORTIGUADORCON /CABLE REFUERZODE5/4"DE LISTADOPORULCARGA /
/CABLES ELECTRICOS CONDUCTORESDE COBRE N0M i0 AWG DE POR LO
MENOS
4 HILOS O KIT DE CABLE DE CORRIENTE DE
120/240V 30 A MARCADO PAPA USO CON
SECADORAS Y PROVISTO CON TERMINALES
DE BUCLE CERRADO O CON HORQUILLA
CON EXTREMOS HACIA ARRIBA (NO PROVISTO)
!. Apague el disyuntor(es)(:30 amperios) o retire el fusibledel
circuito de la secadora de la caja de electricidad.2. AsegOrese de
que el cable del electrodom6stico est6desenchufado del recept6culo
de la pared.:3.Retire la tapa del cable de corriente ubicada en la
parteinferior trasera.4. Retire y descarte la cinta de conexi6n a
tierra. Conserveel tornillo verde de conexi6n a tierra para el paso
7.5. Instale el amortiguador con refuerzo de 3A pulgadaslistado par
ULdel agujero de entrada del cable de corriente.Paseel cable de
corriente par el amortiguador con refuerzo.
5
-
Instruccionesde Instalaci6n
CONE×ION DEL ELECTROD.OMI_STICOUTILIZANDO UNA CONE×ION DE
4CABLES (SE DEBERA USAR PARA LAINSTALACION EN VIVIENDAS
MOVILES).
6. Conecte del cable de corriente del siguiente modo:A. Conecte
los 2 polos de carga o los tornillosexteriores del bloque terminal
(marcados L1y L2).B.Conecte el polo neutral (blanco) al centro del
bloqueterminal (marcado N).
7. Adjunte el cable o tierra del cable de corriente altornillo
verde de conexi6n a tierra (agujero sabre elsoporte del
amortiguador con refuerzo). Ajuste todoslos tornillos (3)del bloque
de terminales firmemente.
8. Asegure el cable de corriente al amortiguador
conrefuerzo.
9. Vuelva a instalar la tapa.
ADVERTENCIA: NUNCADEJE LA TAPA FUERA DELBLOOUE DE
TERMINALES.
LONGITUD
DEL ESCAPE
de Codos
900
o1
2
24" LONGITUD M/_,XIHA RECOMENDADA
Tipos de Campanas de Escape
Use s61oparainstalaciones cortas
Recomendado:
Metal Rigido Metal Rigido
43 Pies 36 Pies33 Pies 26 Pies24 Pies t6 Pies
.Para cada coda adicional de 90°, reduzca en 10 pies laIongitud
permisible del sistema de escape.Doscodasde450deber6nser
consideradoscomaun coda de
90°. Para el escape lateral, agregue un coda de 90° a
latabla.
.La Iongitud total del sistema de escape incluye todas
lasporciones rectas y todos los codas del sistema (incluyendoel
ducto de transici6n).
[_] INFORMACI6N SOBRE EL ESCAPE
ADVERTENCIA - EN CANADA
YENESTADOSUNIDOS,ELDI#,METRODELCONDUCTODEESCAPEREQUERIDO ESDE4"
(i02 mm.). NOUSECONDUCTOSM#,S LARGOS QUE
LOSESPECIFICADOSENLATABLADELONGITUDDELESCAPE.El usa de un escape
m6s largo que el especificado:, Incrementar6 los tiempos de secado
y el costa deenergia., Reducir6 la vida 0til de la secadora.,
Acumular6 pelusa, creando un posible riesgo deincendio.Es SU
RESPONSABILIDAD qua el escapeest_ instalado correctamente.
Cualquier problemadebido a una instalaci6n incorrecta no
estar6cubierto par este garanti.e.Retirey ehmine pldsticos u hojas
de aluminio existentesen el conducto de transicl6n y reemplace par
elconducto de transici6n que figura en la lista de UL.
Lu Iongitud M_,XIMA PERMITIDA del conducto y lucantidad de
torsiones del sistema de escape dependedel tipo de conducto, nOmero
de giros, el tipo decampana de escape (caperuza de pared), y
todaslas condiciones indicadas previamente) La Iongitudm6xima para
conductos de metal rigido figura en lasiguiente tabla.
27" LONGITUD M/_×IMA RECOMENDADA
LONGITUD Tipos de Campanas de Escape
DEL ESCAPE Recomendado: Use s61oparainstalaciones cortas
lDi6metro..._ Di6metro_/_id_" ,,_ de'!" ,_1
4NOde Codas Metal Rigido Metal Rigidode 900
0 56 Pies 42 Pies
1 48 Pies 34Pies2 40 Pies 26 Pies3 32 Pies 18 Pies
INFORMACI6N SOBRE EL ESCAPE
LISTA DE CONTROL DEL SISTEMA DE ESCAPE
CAMPANAOCAPERUZADEPARED• Terminarde modo quese eviten r6fagasde
aire traseraso laentrada de p6jarosu otrosanimales.
• La terminaci6n deberia presentar una resistencia minimasabre
el flujo del aire del escapey deberb requerir poco
oningOnmantenimientopara evitar obstrucciones.
• Nunca instale una rejilla en o sabre el conducto de
escape.Estopodria ocasionarla acumulaci6nde pelusa.
• Lascaperuzasde paredse debeninstalar par Io menosa !2"sabreel
nivelde suelo o en cualquier otra obstrucci6ncon laabertura en
direcci6nhaciaabajo.
SEPARACI6N DE CURVAS
Paraunmejorfuncionamiento,
separetodasloscurvasaparJomenos/4piesdetconductorecto,incluyendoladistanciaentreet61timogiroylacampanadeescape.CURVASQUE
NO EST/_NA90°• Unacurvade/4S° omenospodr6serignorada.•
Doscurvasde/45° sedeber6ntratarcomaunacurvade90°.•Cada
curvasuperiora/45° sedeber6tratarcomaunacurvade90°.SELLADODEJUNTAS•
Todaslasjuntas
deber6nestarajustadasparaevitargoteras.Elextremomachodecadasecci6ndetconductodeber6estarapartadodelasecadora.
• Noensamblela tuberiacon tensoresque se
extiendansabreetconducto.Estosservir6ncomapuntosderecolecci6ndepetusa.
• Sepodr6evitar la entradade airey humedaden lasjuntas
detconductoenvotviendolasjuntasde farina superpuestacon
cintaparaconducto.
• Lasparteshorizontalesdeber6ntenet unacaidade !/4" par
piehaciaetexterior.
AISLANTECuando el conducto atraviese un @easin calefacci6no
est_cercade un acondicionadorde aire,deber6ser aisladoa fin
dereducir la condensaci6ny laacumulaci6n depelusa.
6
-
Instruccionesde Instalaci6n
J-4-JCONE×I6N DEL ESCAPE
ADVERTENCIA - PARAREDUCIREL RIESGO DE INCENDIO O
LESIONESPERSONALES:
, Esteelectrodom6stico deber6 cont(]r con un escapehacia el
exterior.
, Use s61o un conducto de metal r[gido de 4" p(]r(] elconducto
de s(]lida del hog(]r.Use s61o un conducto de metal rigido de 4"0
demetal flexible de I(] list(] de UL(semi-r[gido o tipo hoj(]de
(]luminio) p(]m conectar I(] sec(]dom (]1conductode escape del
hog(]r. Se deber6 inst(]l(]r de (]cuerdocon las instrucciones que
figumn en "Conexi6n de laSec(]dom (] I(] Ventil(]ci6n del Hog(]r"
en I(] p6gin(] 8de este manual.No termine I(] s(]lida del escape en
un(] chimene(],pared, cielo mso, ventil(]ci6n de gas, s6t(]no,
6tico,deb(]jo de un piso (]djunto, o en cu(]lquier esp(]ciooculto
de un(] construcci6n. L(] (]cumul(]ci6n depelus(]s podH(] provoc(]r
un riesgo potenci(]l deincendio.Nunc(] termine el escape en un
conducto comOncon un sistem(] de escape de un(] cocin(].
L(]combin(]ci6n de gr(]s(] y pelus(] cre(] un posibleriesgo de
incendio.Evite que el conducto sea m6s largo que como seespecific(]
en I(] t(]bl(] de Iongitud del escape. Losconductos m6s largos
(]cumul(]n pelus(], cre(]ndoun posible riesgo de i