INSTRUCTIONS
This instruction manual is for the Olympus Control Box Model
U-CBM for use in the control of moto-rized microscope modules and
Hand Switch Model U-HSCBM for use in the operation of the CBM.To
ensure the safety, obtain optimum performance and to familiarize
yourself fully with the use of the motorized modules, we recommend
that you study this manual thoroughly before operating the
microscope system.Retain this instruction manual in an easily
accessible place near the work desk for future reference.
A X 7 9 3 8
CONTROL BOXHAND SWITCH FOR CBM
U-CBMU-HSCBM
-
In accordance with European Directive 2002/96/EC on Waste
Electrical and Electronic Equipment,
this symbol indicates that the product must not be disposed of
as unsorted municipal waste, but
should be collected separately.
Refer to your local Olympus distributor in EU for return and/or
collection systems available in your
country.
NOTE: This equipment has been tested and found to comply with
the limits for a Class A digital device, pur-
suant to Part 15 of the FCC Rules. These limits are designed to
provide reasonable protection against
harmful interference when the equipment is operated in a
commercial environment. This equipment
generates, uses, and can radiate radio frequency energy and, if
not installed and used in accordance
with the instruction manual, may cause harmful interference to
radio communications.
Operation of this equipment in a residential area is likely to
cause harmful interference in which case
the user will be required to correct the interference at his own
expense.
FCC WARNING: Changes or modifications not expressly approved by
the party responsible for compliance
could void the user 's authority to operate the equipment.
-
CONTENTS
IMPORTANT -- Be sure to read this section for safe use of the
equipment. -- 1,2
1 NOMENCLATURE 3,4
2 OPERATION 5-8
U-CBM/U-HSCBM
2 Turning the Power ON 1 Setting the DIP Switch Operation
3 Using the OPERATION Buttons 4 Using the OBSERVATION
Buttons
3 DETAILS OF FACTORY-PRESET DATA 9-11
4 SPECIFICATIONS 12
5 TROUBLESHOOTING GUIDE 13
6 SYSTEM CONNECTION 14,15
n PROPER SELECTION OF THE POWER SUPPLY CORD
..............................................................16,17
Connecting the Power Cord
.......................................................................................................................................................................................15
5 Using the FL SHUTTER Button 6 Using the MEMORY Button
-
1
U-CBM/U-HSCBM
SAFETY PRECAUTIONS
IMPORTANT
1. If potentially infectious samples may be observed, use
protective gloves or other protective means to prevent the skin
from contacting with samples directly.
After observation, be sure to clean the portion contacted with
samples. · Moving this product is accompanied with the risk of
dropping the sample. Be sure to remove the sample before moving
this product. · In case the sample is damaged by erroneous
operation, promptly take the infection prevention measures. ·
Follow the procedures described in Chapter “Getting Ready” (see on
page 2) prior to using the accessories of this product.
Otherwise, the stability of the device will be lost and the
dropped sample will cause the possibility of infection. · When you
maintain the device which may have contacted with potentially
infectious reagents, be sure to wear the
protectors such as gloves, or clean the device prior to
operation. · Before disposing of device contacted with potentially
infectious samples, be sure to follow the regulations and rules
of your local government.2. Be sure to set the main switch of
the U-CBM control box to “ ” (OFF) before connecting or
disconnecting the cables.3. Always ensure that the grounding
terminals are properly connected. If the equipment is not grounded,
Olympus can no
longer warrant the electrical safety performance of the
equipment.4. When installing the control box, make sure to place it
on the bottom panel and allow ample free spaces (10 cm or more)
around it.5. If the power cord or a connection cable contacts
the lamp housing or its surroundings, the cord or cable may melt
and
cause an electric shock hazard. Distribute the power cord and
connection cables at enough distances from the lamp housing.
Safety Symbols
The following symbols are found on the system. Study the meaning
of the symbols and always use the equipment in the safest possible
manner.
Symbol Explanation
Indicates a non-specific general hazard. Follow the description
given after this symbol or in instruction manual.
Indicates that the main switch is ON.
Indicates that the main switch is OFF.
The U-CBM control box is used to control motorized modules*
installed on the BX43 or BX53 manual microscope. The motorized
module control functions of the control box can be operated from
the U-HSCBM hand switch or computer. * Include the BX3-UCD8A
motorized universal condenser, U-D7REA motorized 7 position
nosepiece,
BX3-RFAA motorized fluorescence illuminator and U-AW motorized
attenuator wheel.
-
2
3 Caution
If the instruments are used in a manner not specified by this
manual, the safety of the user may be imperiled. In addition, the
equipment may also be damaged. Always use the equipment as outlined
in this instruction manual.
The following symbols are used to set off text in this
instruction manual.
: Indicates a potentially hazardous situation which, if not
avoided, may result in minor or moderate injury or damage to the
equipment or furniture in the surroundings. This symbol is also
used to warn against risky actions.
} : Indicates commentary (for ease of operation and
maintenance).
CAUTION
1 Getting Ready
1. These products are precision instruments. Handle them with
care and avoid subjecting them to sudden or severe impact and also
connect the cables gently.
2. Do not use the instruments where they are subjected to direct
sunlight, high temperature and humidity, dust or vibrations. (For
the operating conditions, refer to Chapter 4, “SPECIFICATIONS” on
page 12.)
3. To prevent malfunction, do not replace modules or
connect/disconnect cables while the main switch of the U-CBM is set
to “ I ” (ON).
4. Do not disassemble any part of the instruments, as this could
result in malfunction.5. When the accessories of this product such
as an intermediate attachment are used, make sure that the system
height
does not exceed 1 meter (to prevent the system from tipping
over).6. Before disposing of this product, be sure to follow the
regulations and rules of your local government.
This product complies with the requirements of directive
98/79/EC concerning in vitro diagnostic
medical devices. CE marking means the conformity to the
directive.
2 Intended use
This product has been designed to be used to observe magnified
images of specimens in various routine work and research
applications.
Do not use this product for any purpose other than its intended
use. This product is considered a medical device in the following
country: US.
Safety and EMC Precautions
· This product complies with the emission and immunity
requirements described in IEC61326 series. · The electromagnetic
environment should be evaluated prior to operation of this product.
Do not use this product in
close proximity to the sources of strong electromagnetic
radiation to prevent interference with the proper operation. · Use
only power cord which OLYMPUS specifies. Otherwise the safety and
EMC performance of the product can not
be assured. · Be sure to ground the product. Otherwise our
intended electric safety and EMC performance of the product can
not
be assured.
Use in domestic area
EN61326-1 defines two categories according to the location for
use.Class A: Equipment suitable for use in establishments other
than domestic, and those directly connected to a low voltage
power supply network which supplies buildings used for domestic
purposes.Class B: Equipment for use in domestic establishments, and
in establishments directly connected to a low voltage power
supply network which supplies buildings used for domestic
purposes.This product is applied Class A. Some interference may
occur if this system is used in domestic location.
-
3
U-CBM/U-HSCBM
1 NOMENCLATUREControl Box U-CBM
Main switch
“ I ”: ON. “ ”: OFF.
Rotary switch (P. 5)
For use in observation mode selection.
DIP switches (P. 5)
For use in operation setting.
REMOTE indicator
Blue lighting: Computer-controlled.OFF: Hand
switch-controlled.
ERROR indicator
Red blinking: Error generated.OFF: No error.
Connected module indicators(Lights in green when the module is
connected and blinks in case of an error.)
DC input connector
24 V/2.8 A
RS-232C connector
Output connector to the computer or DP21 control box.
OUT-1 to OUT-4 connectors
Universal output connectors to the modules.
Hand switch connector
CBS connector
AC adapter
Power cord connector
Power output plug
ILL: Motorized fluorescence illuminator (BX3-RFAA)NP: Motorized
7 position nosepiece (U-D7REA)UCD: Motorized universal condenser
(BX3-UCD8A)AW: Motorized attenuator wheel (U-AW)CBS: Control box
for coded function (U-CBS)HS: Hand switch for CBM (U-HSCBM)
-
4
Hand Switch U-HSCBM
} The button operation of a motorized module being driven by the
previous button operation is invalid.
* These buttons are defeated when the U-D7RES motorized 7
position nosepiece or the BX3-RFAS coded fluorescence illuminator
is used.
ATTENUATOR buttons
For use in switching of the ND filters.
MIRROR buttons*
For use in switching of the mirror units.
OBJECTIVE buttons*
For use in switching of objectives.
MEMORY button
FL SHUTTER button
Connector
OBSERVATION buttons
· DF: Darkfield observation · PO: Polarized light observation ·
BF: Brightfield observation · DIC: Differential interference
contrast observation · PH: Phase contrast observation · FL:
Fluorescence observation
-
5
U-CBM/U-HSCBM
2 OPERATION
Fig. 1
1 Setting the DIP Switch Operation (Fig. 1)
} The DIP switches have been covered with dust protection
stickers at the factory. Peel off these stickers before setting and
attach the provided stickers after setting.
· Be sure to set the main switch @ to “ ” (OFF) before changing
the DIP switch setting (ON-OFF switching). The DIP switch setting
is entered at the moment the main switch is set to “ I ” (ON).
· Be careful not to touch the internal circuit boards during DIP
switch setting. Otherwise, damage due to static electricity may
result. Also, as the human body is charged with static electricity,
be sure to discharge the static electricity from your body before
proceeding to the setting. The static electricity in your body can
be discharged by simply touching a metallic object in your
proximity.
DIP SW 1-1/2 (² in Fig. 1)
· DIP SW1-1 (Default: OFF)OFF: Initialization is executed at
power ON.ON: Initialization is not executed at power ON.
· DIP SW1-2 (Default: OFF)OFF: Confirmation tone is generated.
(One short beep if normal.)ON: Confirmation tone is not
generated.
· DIP SW1-3 (Default: OFF)OFF: BX seriesON: IX series
DIP SW1-4 to 8/DIP SW2-1 to 8 (³ in Fig. 1)
· Reserved for manufacturer’s use.
Observation mode selector rotary switch (| in Fig. 1)
· Using a Phillips screwdriver, turn the rotary switch | to set
the microscope. The switch has 16 positions numbered from 0 to
F.
0: Empty (Default)1: BF plan semi-apo set2: BF plan apo set3: BF
no-cover set4: BF plan set5: DIC plan apo set6: DIC plan semi-apo
set7: PH plan semi-apo set8: PH plan set9-F: Empty
} For the information on factory preset 1 data to 8, see page
9-11.
132
CAUTION
4
-
6
Fig. 2
Fig. 3
2 Turning the Power ON (Fig. 2)
3 Using the OPERATION Buttons (Fig. 3)
Confirm that the modules to be used are connected properly (see
page 14).
1. Set the main switch @ to “ I ” (ON).2. Ensure that the
connected module indicators ² of the connected modules
are lit correctly.3. If DIP SW1-1 is set to OFF, the motorized
modules of the microscope are
initialized (about 5 seconds). · The revolving nosepiece is not
moved. · The aperture iris diaphragm (AS), top lens, turret and
polarizer of the
condenser are initialized and then moved to the positions for
the last observation mode used and current objective.
· The U-AW motorized attenuator wheel is initialized and then
moved to the last position
} The button operation of a motorized module being driven by the
previous button operation is invalid.
ATTENUATOR buttons @} These buttons adjust the brightness of the
reflected fluorescence
source. Each button is defeated when the limit in the
t
or t direction is reached.
t
direction: Switches the ND filter for attenuating the
brightness.
t direction: Switches the ND filter for increasing the
brightness.
MIRROR buttons ²} These buttons switch the mirror units for the
reflected fluorescence.
t
direction: Switches the mirror units toward the left when the
fluorescence illuminator is seen from the front.
t direction: Switches the mirror unit toward the right when the
fluorescence illuminator is seen from the front.
OBJECTIVE buttons ³} These buttons switch the objectives. The
modules (including the condenser’s aperture iris diaphragm for
the
transmitted light, turret, polarizer, etc.) are moved to the
positions that are stored in memory according to the observation
mode.
t
direction: Switches the objective toward the left when the
nosepiece is seen from the front.
t direction: Switches the objective toward the right when the
nosepiece is seen from the front.
1
3
2
CAUTION
1
2
-
7
U-CBM/U-HSCBM
Fig. 4
4 Using the OBSERVATION Buttons (Fig. 4)
5 Using the FL SHUTTER Button (Fig. 4)
} The button operation of a motorized module being driven by the
previous button operation is invalid.
} The positions and setting values of the motorized modules are
determined (stored in memory) according to the selected OBSERVATION
button and objective position.
The user can change the factory-preset data of the
positions/setting values and store the newly changed data in memory
using the MEMORY button.
BF (Brightfield) button @ This button moves the optical elements
to the brightfield observation
positions stored in memory for the current objective. The
selected observation mode is indicated by the Indicator LED on
the
left of the area above the selected observation button. DF
(Darkfield) button ² PO (Polarized light) button ³ PH (Phase
contrast) button | DIC (Differential interference contrast) button
ƒ FL (Fluorescence) button … Each of buttons ² to … moves the
optical elements to the respective
positions. The mirror unit position is set to the position used
in the previous FL observation.
} Three kinds of simultaneous fluorescence observations are
possible including FL+BF, FL+PH and FL+DIC. To select one of these
combinations, first press the FL button and then press the BF, PH
or DIC button.
The aperture iris diaphragm (AS), turret, top lens and polarizer
of the condenser cannot be moved during FL observation.
} This button opens or closes the shutter of the fluorescence
illuminator. When observation is not required, press the FL SHUTTER
button † to
close the shutter to prevent the specimen color fading. Press
the button again to open the shutter.
13
2
4
6
5
7
CAUTION
-
8
Fig. 5
6 Using the MEMORY Button (Fig. 5)
} The user can change the factory-preset data for each of the
combinations of the “objective” being engaged in the light path and
the “observation mode” being selected and store the newly changed
data in memory.
Data that can be changed and stored in memory
· Fluorescence illuminator (BX3-RFAA): Mirror unit/shutter ·
Motorized condenser (BX3-UCD8A): Turret/AS/top lens/polarizer1.
After setting the required data as desired, press and hold the
MEMORY
button @ for more than a second. A short beep is generated and
the new data is stored in memory.
2. Select the next combination of “objective” and “observation
mode,” change its data and store it in memory.
Resetting data to the factory-preset data} All of the data
changed by the user can be reset simultaneously to the
factory-preset data.1. Set the main switch of the U-CBM control
box to “ ” (OFF).2. While holding down the MEMORY @ and FL SHUTTER
² buttons, set
the main switch of the U-CBM to “ I ” (ON). When the data is
reset to the factory-preset data, a beep will sound. The resetting
starts (provided that DIP SW1-1 is OFF).
If resetting to the factory-preset data fails, five short beeps
are generated and the Indicator LED on the left of the area above
the MEMORY button @ blinks. This indicates a malfunction so please
contact Olympus.
1
2
CAUTION
-
9
U-CBM/U-HSCBM
3 DETAILS OF FACTORY-PRESET DATA} This chapter describes the
factory-preset data of the control box in text and tables.1. With
the factory-preset data for the motorized condenser in FL
observation, the aperture iris diaphragm (AS) is moved to
the completely closed position, the turret to an intermediate
position, the top lens to the OUT position and the polarizer to the
OUT position.
2. With the factory-preset data for the BX3-RFAA motorized
fluorescence illuminator, the shutter is moved to the open position
in FL observation and to the closed position in other observations
(these position data can be changed by the user).
3. With the factory-preset data for the polarized, it is moved
to the IN position in PO/DIC/FL+DIC observations and to the OUT
position in other observations (the position data can be changed to
the OUT position by the user).
4. With the factory-preset data for the aperture iris diaphragm
(AS) in FL+PH/PH/DF observations, the AS is moved to the completely
open position.
5. With the factory-preset data for the BX3-RFAA motorized
fluorescence illuminator in FL observation, the mirror unit is
moved to the position used in the last FL observation.
Factory-Preset Tables} During simultaneous observations, the
operations of the motorized modules become identical to the
observation other
than the FL observation. During the FL+BF observations, the
motorized modules perform the same operations as those during the
BF
observation.} Mount the U-CO1.25X low-magnification conversion
lens for UCD in one of turret positions 4 to 7 and register it
using
the MEMORY button.
1: BF plan semi-apo setApplicable observations:BF / PO / FL
BX3-UCD8A motorized universal condenser BX3-RFAA illuminator
Top lens Turret No. Turret No.
Nosepiece position
Objective U-TLD 1 2 3 4 5 6 7 8 Not movedPH / DF / BF
DIC / PO
1 UPLFLN4X OUT
BF / POIdle position
PH / DIC / DF
7. Idle position
8.U-FDICT
2 UPLFLN10X2 IN
3 UPLFLN20X IN
4 UPLFLN40X IN
5 UPLFLN100XO2 IN
6 PLAPON1.25X OUT
7 PLAPON2X OUT
2: BF plan apo setApplicable observations:BF / PO / FL
BX3-UCD8A motorized universal condenser BX3-RFAA illuminator
Top lens Turret No. Turret No.
Nosepiece position
Objective U-TLD 1 2 3 4 5 6 7 8 Not movedPH / DF / BF
DIC / PO
1 PLAPON1.25X OUT
BF / POIdle position
PH / DIC / DF
7. Idle position
8.U-FDICT
2 PLAPON2X OUT
3 UPLSAPO4X OUT
4 UPLSAPO10X2 IN
5 UPLSAPO20X IN
6 UPLSAPO40X2 IN
7 UPLSAPO100XO IN
-
10
3: BF no-cover setApplicable observations:BF / PO / FL
BX3-UCD8A motorized universal condenser BX3-RFAA illuminator
Top lens Turret No. Turret No.
Nosepiece position
Objective U-TLD 1 2 3 4 5 6 7 8 Not movedPH / DF / BF
DIC / PO
1 PLAPON1.25X OUT
BF / POIdle position
PH / DIC / DF
7. Idle position
8.U-FDICT
2 PLAPON2X OUT
3 UPLFLN4X OUT
4UPLFLN10X2
(MPLFLN10X)IN
5 MPLFLN20X IN
6 MPLFLN40X IN
7 MPLFLN100X IN
4: BF plan setApplicable observations:BF / PO / FL
BX3-UCD8A motorized universal condenser BX3-RFAA illuminator
Top lens Turret No. Turret No.
Nosepiece position
Objective U-TLD 1 2 3 4 5 6 7 8 Not movedPH / DF / BF
DIC / PO
1 PLN2X(PLCN2X) OUT
BF / POIdle position
PH / DIC / DF
7. Idle position
8.U-FDICT
2 PLN4X(PLCN4X) OUT
3 PLN10X(PLCN10X) IN
4 PLN20X(PLCN20X) IN
5 PLN40X(PLCN40X) IN
6 PLN100X(PLCN100X) IN
5: DIC plan apo setApplicable observations:BF / DIC / FL
BX3-UCD8A motorized universal condenser BX3-RFAA illuminator
Top lens Turret No. Turret No.
Nosepiece position
Objective U-TLD 1 2 3 4 5 6 7 8 Not movedPH / DF / BF
DIC / PO
1 UPLSAPO10X2 INDIC
U-DIC10S
BF / POIdle position
PH / DF7. Idle
position8.U-FDICT
2 UPLSAPO20X INDIC
U-DIC20
3 UPLSAPO40X2 INDIC
U-DIC40
4 UPLSAPO60XO INDIC
U-DIC60
5 UPLSAPO100XO INDIC
U-DIC100
-
11
U-CBM/U-HSCBM
6: DIC plan semi-apo setApplicable observations:BF / DIC /
FL
BX3-UCD8A motorized universal condenser BX3-RFAA illuminator
Top lens Turret No. Turret No.
Nosepiece position
Objective U-TLD 1 2 3 4 5 6 7 8 Not movedPH / DF / BF
DIC / PO
1 UPLFLN10X2 INDIC
U-DIC10S
BF / POIdle position
PH / DF7. Idle
position8.U-FDICT
2 UPLFLN20X INDIC
U-DIC20
3 UPLFLN40X INDIC
U-DIC40
4 UPLFLN60XOI INDIC
U-DIC60
5 UPLFLN100XO2 INDIC
U-DIC100
7: PH plan semi-apo setApplicable observations:BF / PH / DF /
FL
BX3-UCD8A motorized universal condenser BX3-RFAA illuminator
Top lens Turret No. Turret No.
Nosepiece position
Objective U-TLD 1 2 3 4 5 6 7 8 Not movedPH / DF / BF
DIC / PO
1 UPLFLN4X OUT
BF / POIdle position
DIC7. Idle
position8.U-FDICT
2 UPLFLN10X2PH INPH
U-PH1-SDF
U-DFA
3 UPLFLN20XPH INPH
U-PH1-SDF
U-DFA
4 UPLFLN40XPH INPH
U-PH2-SDF
U-DFA
5 UPLFLN100XO2PH INPH
U-PH3-S
8: PH plan setApplicable observations:BF / PH / DF / FL
BX3-UCD8A motorized universal condenser BX3-RFAA illuminator
Top lens Turret No. Turret No.
Nosepiece position
Objective U-TLD 1 2 3 4 5 6 7 8 Not movedPH / DF / BF
DIC / PO
1 PLN4X OUT
BF / POIdle position
DIC7. Idle
position8.U-FDICT
2 PLN10XPH INPH
U-PH1-SDF
U-DFA
3 PLN20XPH INPH
U-PH1-SDF
U-DFA
4 PLN40XPH INPH
U-PH2-SDF
U-DFA
5 PLN100XOPH INPH
U-PH3-S
-
12
44 SPECIFICATIONSItem Specification
Control Box U-CBM
Rating Output: 24 V/2.8 AInput: AC adapter, 100-240 V AC, 50-60
Hz, 1.7 A
Indicator LEDs · REMOTE indicator. · ERROR indicator. ·
Connected module indicators:
ILL, NP, UCD, AW, CBS, HS.
DIP switch · Operation-setting DIP switch. · Observation mode
selection rotary switch (16 positions from 0 to 9 and A to F).
Dimensions & weight 185(W) x 48(H) x 120(D) mm, approx. 0.82
kg.
Hand Switch for CBM U-HSCBM
Button functions · Observation mode selector buttons:DF, PO, BF,
DIC, PH, FL.
· ATTENUATOR buttons
t
/ t
· MIRROR buttons
t
/ t
· OBJECTIVE buttons
t
/ t
· MEMORY button · FL SHUTTER button
Dimensions & weight 147(W) x 32(H) x 108(D) mm, approx. 0.31
kg
Operating environment
· Indoor use. · Altitude: Max. 2000 meters · Ambient
temperature: 5° to 40°C (41° to 104°F) · Maximum relative humidity:
80% for temperatures up to 31°C (88°F), decreasing linearly through
70% at 34°C (93°F),
60% at 37°C (99°F), to 50% relative humidity at 40°C (104°F). ·
Supply voltage fluctuations: ±10% · Pollution degree: 2 (in
accordance with IEC60664-1) · Installation/Overvoltage category: II
(in accordance with IEC60664-1)
Transport / Storage environment
· Temperature: Min. -25°C, Max. 65°C · Humidity: Min. 0%, Max.
90%
-
13
U-CBM/U-HSCBM
TROUBLESHOOTING GUIDE5 Under certain conditions, performance of
the instruments may be adversely affected by factors other than
defects. If problems
occur, please review the following list and take remedial action
as needed. If you cannot solve the problem after checking the
entire list, please contact your local Olympus representative for
assistance.
Problem Cause Remedy Page
The ERROR indicator blinks. The module indicated by the
connec-ted module indicator blinking together is connected
improperly.
Connect the indicated motorized module properly. 14
The power cannot be turned on by setting the main switch to “ I
” (ON).
The power cord is disconnected. Connect the power cord
properly.15
RS-232C communication is not available.
An inappropriate RS-232C cable is used.
Replace with the specified RS-232C cable.
14
The RS-232C cable is connected improperly.
Connect the cable properly.14
The hand switch buttons are invalid and the indicator LEDs are
not lit.
The hand switch is connected im-properly.
Connect it properly.14
A motorized module cannot be ope-rated and the connected module
indicator for it is not lit.
The motorized module is connected improperly/
Connect it properly.14
-
14
6 SYSTEM CONNECTION · Be sure to set the main switches of the
U-CBM control box and U-CBS to “ ” (OFF) before connecting the
cables. The following diagram shows only the cable connections
associated with the U-CBM. · Always connect the connectors to the
modules designated by Olympus. When connecting each connector,
align the connector orientation correctly and insert the
connector all the way. If a connector is equipped with lock screws,
always tighten them firmly.
CAUTION
RS-232C cable***
Control box for DP21
AC adapter
Power cord
CBS cable (Provided with U-CBM)
Coded 7 position nosepieceU-D7RES
Coded fluorescence illuminatorBX3-RFAS
Control box for coded function**U-CBS
Hand switch for CBMU-HSCBM
U-IFCBL200 cable
Motorized attenuator wheelU-AW
Control boxU-CBM
U-IFCBL200 cable
Motorized 7 position nosepieceU-D7REA
U-IFCBL200 cable
Motorized fluorescence illuminatorBX3-RFAA
U-IFCBL200 cable
Motorized universal condenserBX3-UCD8A
*The OUT 1 to 4 connectors are universal type connectors and can
be connected to any module.**Do not attempt to connect the U-CBS
and U-CBM using the RS-232C cable provided with the U-CBS control
box.
*** The RS-232C cable should be a commercially available
straight cable (do not use other types of cable to prevent
malfunction).
The RS-232C cable should be equipped with D-sub 9-pin (female)
D-sub 9-pin (female) connectors.
* *
*
*Computer(Software cellSens Ver. 1.4 or later should be
installed.)
-
15
U-CBM/U-HSCBM
Connecting the Power Cord (Figs. 6 & 7)
Always use the power cord provided by Olympus. If no power cord
is provided, please select the proper power cord by referring to
the section “PROPER SELECTION OF THE POWER SUPPLY CORD” at the end
of this instruction manual.
1. Insert the connector @ of the power cord into the connector ²
of the AC adapter.
The power cord should be connected to a grounded/earthed,
3-conductor power outlet. If the power outlet is not
grounded/earthed properly, Olympus can no longer warrant the
electrical safety performance of the equipment.
2. Plug the power cord plug ³ into the wall outlet |.
Should the power cord come in contact with the hot lamp
hou-sing, the power cord could melt and cause electric shock. Be
sure to route the power cord away from the lamp housing.
3. Bundle the connection cables using the three Velcro tapes
provided with the U-CBM.
CAUTION
CAUTION
CAUTION
Fig. 6
Fig. 7
43
1
2
-
16
n PROPER SELECTION OF THE POWER SUPPLY CORD
If no power supply cord is provided, please select the proper
power supply cord for the equipment by referring to “
Specifications ” and “ Certified Cord ” below:CAUTION: In case you
use a non-approved power supply cord for Olympus products, Olympus
can no longer warrant the
electrical safety of the equipment.
Specifications
Voltage RatingCurrent RatingTemperature RatingLengthFittings
Configuration
125V AC (for 100-120V AC area) or, 250V AC (for 220-240V AC
area)6A minimum60˚C minimum3.05 m maximumGrounding type attachment
plug cap. Opposite terminates in molded-on IEC configuration
appliance coupling.
Table 1 Certified Cord
A power supply cord should be certified by one of the agencies
listed in Table 1 , or comprised of cordage marked with an agency
marking per Table 1 or marked per Table 2. The fittings are to be
marked with at least one of agencies listed in Table 1. In case you
are unable to buy locally in your country the power supply cord
which is approved by one of the agencies mentioned in Table 1,
please use replacements approved by any other equivalent and
authorized agencies in your country.
Country AgencyCertification
Mark Country AgencyCertification
Mark
Argentina IRAM Italy IMQ
Australia SAA Japan JET, JQA, TÜV,UL-APEX/MITI
Austria ÖVE Netherlands KEMA
Belgium CEBEC Norway NEMKO
Canada CSA Spain AEE
Denmark DEMKO Sweden SEMKO
Finland FEI Switzerland SEV
France UTE United KingdomASTABSI
Germany VDE U.S.A. UL
Ireland NSAI
-
17
U-CBM/U-HSCBM
Table 2 HAR Flexible Cord
APPROVAL ORGANIZATIONS AND CORDAGE HARMONIZATION MARKING
METHODS
Approval Organization
Printed or Embossed Harmoni-zation Marking (May be located on
jacket or insulation of internal wiring)
Alternative Marking Utilizing Black-Red-Yellow Thread (Length of
color section in mm)
Black Red Yellow
Comite Electrotechnique Belge(CEBEC) CEBEC 10 30 10
Verband Deutscher Elektrotechniker(VDE) e.V. Prüstelle 30 10
10
Union Technique de I´Electricite´(UTE) USE 30 10 30
Instituto Italiano del Marchio diQualita´ (IMQ) IEMMEQU 10 30
50
British Approvals Service for ElectricCables (BASEC) BASEC 10 10
30
N.V. KEMA KEMA-KEUR 10 30 30
SEMKO AB Svenska ElektriskaMaterielkontrollanstalter SEMKO 10 10
50
Österreichischer Verband fürElektrotechnik (ÖVE) 30 10 50
Danmarks Elektriske Materialkontroll(DEMKO) 30 10 30
National Standards Authority of Ireland (NSAI) 30 30 50
Norges Elektriske Materiellkontroll(NEMKO) NEMKO 10 10 70
Asociacion Electrotecnica YElectronica Espanola (AEE) 30 10
70
Hellenic Organization forStandardization (ELOT) ELOT 30 30
70
Instituto Portages da Qualidade(IPQ) np 10 10 90
Schweizerischer ElektroTechnischer Verein (SEV) SEV 10 30 90
Elektriska Inspektoratet SETI 10 30 90
Underwriters Laboratories Inc. (UL) SV, SVT, SJ or SJT, 3 X
18AWG Canadian Standards Association (CSA) SV, SVT, SJ or SJT, 3 X
18AWG
-
MEMO
-
Printed in Japan on October 15, 2010 M 002-05