Page 1: Instructions and HORIZONTAL INERTIAL STORAGE TANK KIT

HORIZONTALINERTIAL

STORAGE TANK KIT

25 -75 - 100 - 200 Litres

Instructions and warning book

Page 2: Instructions and HORIZONTAL INERTIAL STORAGE TANK KIT

9

IE

INDEX

1 Inertial storage tank installation. ................................................................................................................................................................................................ 101.1 Installation recommendations. ................................................................................................................................................................................................... 101.2 Operation. ...................................................................................................................................................................................................................................... 101.3 Main features. ................................................................................................................................................................................................................................ 101.4 Hydraulic connection. .................................................................................................................................................................................................................. 101.5 Technical data. .............................................................................................................................................................................................................................. 101.6 Main dimensions .......................................................................................................................................................................................................................... 111.7 Main components ......................................................................................................................................................................................................................... 131.8 Hydraulic diagram. ....................................................................................................................................................................................................................... 15

1 INSTALLATION INERTIAL STORAGE TANK.

1.1 INSTALLATION RECOMMENDATIONS.

The place of installation of the appliance and relative Immergas accessories must have suitable features (technical and structural), such as to al-low for (always in safe, efficient and comfortable conditions):- installation (according to the provisions of

technical legislation and technical regulations);- maintenance operations (including scheduled,

periodic, routine and special maintenance);- removal (to outdoors in the place for loading

and transporting the appliances and com-ponents) as well as the eventual replacementof those with appliances and/or equivalentcomponents.

Installation must be carried out according to current technical regulation standards, current legislation and in compliance with local tech-nical regulations and the required technical procedures.Before installing the inertial storage tank, ensure that it is delivered in perfect condition; if in doubt, contact the supplier immediately. Packing materials (staples, nails, plastic bags, polystyrene foam, etc.) constitute a hazard and must be kept out of the reach of children. There must be suf-ficient clearance around the device in its place of installation to permit normal maintenance. In case of installation under the heat pump, refer to the relevant instruction booklet for the minimum clearances. Keep all flammable objects away from the appliance (paper, rags, plastic, polystyrene, etc.).

Failure to comply with the above implies personal responsibility and invalidates the warranty.

At the end of its service life, the appliance must not be disposed of like normal household waste nor abandoned in the environment, but must be removed by a professionally authorised company. Contact the manufacturer for disposal instructions.

1.2 OPERATION.Immergas inertial storage tanks are used to stabilise the primary system for the heat pumps.Thanks to the special arrangement of the hydrau-lic connections, the hydraulic layout may vary according to the relevant use and requirements.

1.3 MAIN FEATURES.The inertial storage tanks can be connected to Immergas heat pumps thanks to the same fixing centre distances.All models are supplied with anti-vibrating supports (heat pump fixed above inertial stor-age tank).The inertial storage tanks are complete with an insulating casing 20 mm thick.The devices are provided with 2 connections.Furthermore each device has a connection for the drain with relative valve and the air vent valve.

Warning: it is recommended to perform the earthing connection.

1.5 TECHNICAL DATA.

25 Litres 75-Litre 100 Litres 200 Litres

Effective capacity litres 27 65 91.8 183.6

Nominal capacity litres 25 75 100 200

Dimensions mm 910 x 425 x 450 910 x 425 x 450 1240 x 425 x 450 1240 x 821 x 450

Max. operating temperature °C 90 90 90 90

Max. operating pressure bar 3 3 3 3

Max. Inspection pressure bar 4.5 4.5 4.5 4.5

Empty weight kg 36 42,5 54,2 107,4

Full weight kg 63 107,5 146 291

1.4 HYDRAULIC CONNECTION.A treatment of the heating and water system wa-ter is required, in compliance with the technical standards in force, in order to protect the system and the appliance from deposits (e.g. scale), slurry or other hazardous deposits.

Hydraulic connections must be carried out in a rational manner using the relevant fittings, connecting these to the system return pipe of the heat pump (Fig. 1-9).

Page 3: Instructions and HORIZONTAL INERTIAL STORAGE TANK KIT

10

1-1

1-2

1.6 MAIN DIMENSIONS

25 litre model

75 litre model

4 M10 inserts

4 M10 inserts

8 holes Ø11

8 holes Ø11

Page 4: Instructions and HORIZONTAL INERTIAL STORAGE TANK KIT

11

1-4

1-3100 litre model

200 litre model

8 holes Ø11 4 M10 inserts

4” G1” fittings

4 M10 inserts

8 holes Ø11

Page 5: Instructions and HORIZONTAL INERTIAL STORAGE TANK KIT

12

1.7 MAIN COMPONENTS

1-5

1-6

25 litre model

75 litre model

Key:1 - Fixing brackets2 - Elbow fitting3 - Draining valve4 - Air vent valve5 - Vibration-dampening feet

6 - Storage tank unit7 - Storage tank insulation8 - 1” G-fittings

Key:1 - Fixing brackets2 - Elbow fitting3 - Draining valve4 - Air vent valve5 - Vibration-dampening feet

6 - Storage tank unit7 - Storage tank insulation8 - 1” G-fittings

Page 6: Instructions and HORIZONTAL INERTIAL STORAGE TANK KIT

13

1-8

1-7100 litre model

200 litre model

Key:1 - Fixing brackets2 - Elbow fitting3 - Draining valve4 - Air vent valve5 - Vibration-dampening feet

6 - Storage tank unit7 - Storage tank insulation8 - 1” G-fittings

Key:1 - Fixing brackets2 - Elbow fitting3 - Draining valve4 - Air vent valve5 - Draining valve6 - Air vent valve7 - Vibration-dampening feet

8 - Storage tank unit9 - Storage tank insulation

10 - Fittings connection pipe11 - 1” G-fittings12 - Storage tank unit13 - Storage tank insulation

Page 7: Instructions and HORIZONTAL INERTIAL STORAGE TANK KIT

14

1-9

1.8 HYDRAULIC DIAGRAM.

Key:1 - Heat pump (product to purchase separately)2 - Inertial storage tank3 - Filling cut-off valve (optional)4 - System cut-off valves (optional)

Page 8: Instructions and HORIZONTAL INERTIAL STORAGE TANK KIT

Cod

. 1.0

3988

3 - r

ev. S

T.00

3107

/000

-06/

17

immergas.com

To request further specific details, sector Professionals can also use the following e-mail address: [email protected]

Immergas S.p.A.42041 Brescello (RE) - ItalyTel. 0522.689011Fax 0522.680617

ISO 9001 certified company

Disponibile su Disponibile su Disponibile su

During the service life of the products, performance is affected by external factors, e.g. the hardness of the DHW, atmospheric agents, deposits in the system and so on. The declared data refers to new products that are correctly installed and used in accordance with applicable regulations.NOTE: correct periodic maintenance is highly recommended.

Follow us on Immergas Italia

Immergas TOOLBOXThe App designed by Immergas for professionals