Top Banner
Instruction manual Temperature, Water bottom and Analog output options Page 1 Instruction manual Temperature, Water bottom and Analog output options Version 1.1 September 2002 Part no.: 4416.644_Rev1 Enraf B.V. P.O. Box 812 2600 AV Delft Netherlands Tel.: +31 15 2698600 Fax: +31 15 2619574 E-mail: [email protected] http://www.enraf.com
52

Instruction manual temperature, Water bottom and Analog outp.pdf

Oct 26, 2015

Download

Documents

Javierfox98

manual
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: Instruction manual temperature, Water bottom and Analog outp.pdf

InstructionmanualTemperature,WaterbottomandAnalogoutputoptions Page1

InstructionmanualTemperature,WaterbottomandAnalogoutputoptionsVersion1.1September2002Partno.:4416.644_Rev1

EnrafB.V.P.O.Box8122600AVDelftNetherlands

Tel.:+31152698600Fax:+31152619574E-mail:[email protected]://www.enraf.com

Page 2: Instruction manual temperature, Water bottom and Analog outp.pdf

Page2

Copyright2002EnrafB.V.Allrightsreserved.

ReproductioninanyformwithoutthepriorconsentofEnrafB.V.isnotallowed.Thismanualisforinformationonly.Thecontents,descriptionsandspecificationsaresubjecttochangewithoutnotice.EnrafB.V.acceptsnoresponsibilityforanyerrorsthatmayappearinthismanual.

ThewarrantytermsandconditionsapplicableinthecountryofpurchaseinrespecttoEnrafB.V.productsareavailablefromyoursupplier.Pleaseretainthemwithyourproofofpurchase.

Page 3: Instruction manual temperature, Water bottom and Analog outp.pdf

Preface

InstructionmanualTemperature,WaterbottomandAnalogoutputoptions Page3

Preface

ThismanualisintendedfortechniciansinvolvedwiththecommissioningandserviceoftheEnrafgaugeswiththeoptionalHCUboardorICU_HPIboardinstalled.ThedescriptionfortheanalogleveloutputsettingsarealsoapplicablefortheoptionalICU_HPOboardinthe973SmartRadarLT.

Adescriptionprecedingthetechnicalproceduresgivesthetechnicalinformationnecessarytounderstanditsfunctioning.Itisrecommendedtoreadthisdescriptionpriortoperforminganyoftheprocedures.

Safetyandpreventionofdamage

RefertothechapterSafetyintheinstructionmanualoftheapplicableinstrument(servo/radargaugeorindicator)fordetailedsafetyinstructions.

"Warnings","Cautions",and"Notes"havebeenusedthroughoutthismanualtobringspecialmatterstotheimmediateattentionofthereader.

• AWarningconcernsdangertothesafetyofthetechnicianoruser;• ACautiondrawsattentiontoanactionwhichmaydamagetheequipment;• ANotepointsoutastatementdeservingmoreemphasisthanthegeneraltext,butdoesnotdeservea

"Warning"ora"Caution".

Thesequenceofstepsinaproceduremayalsobeimportantfromthepointofviewofpersonalsafetyandpreventionofdamage;itisthereforeadvisednottochangethesequenceofprocedurestepsoralteraprocedure.

Legalaspects

Thecommissioningandtroubleshootingtotheinstrumentmayonlybeconductedbyqualifiedengineers,trainedbyEnrafandwithknowledgeofsafetyregulationsforworkinginhazardousareas.

TheinformationinthismanualisthecopyrightpropertyofEnrafB.V.,Netherlands.EnrafB.V.disclaimsanyresponsibilityforpersonalinjuryordamagetoequipmentcausedby:

• Deviationfromanyoftheprescribedprocedures;• Executionofactivitiesthatarenotprescribed;• Neglectofthegeneralsafetyprecautionsforhandlingtoolsanduseofelectricity.

ECdeclarationofconformity

TheEnrafinstrument,inwhichtheoptionalHCU,ICU_HPIorICU_HPOboardisinstalled,isinconformitywiththeprotectionrequirementsofECCouncilDirective93/68/EEC.RefertoCEdeclarationofconformitydeliveredwiththeinstrumentortotheinstallationguideoftheinstrument.

Additionalinformation

PleasedonothesitatetocontactEnraforitsrepresentativeifyourequireanyadditionalinformation.

Page 4: Instruction manual temperature, Water bottom and Analog outp.pdf

Tableofcontents

Page4

Tableofcontents

Preface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3

1 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61.1 HCUboard . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61.2 ICU_HPIboard . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61.3 Overviewoffunctions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71.4 HCUcompatibility . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7

1.4.1 Replacementoraddingoptionalboardin854ATGor854XTGservogauges . . . . . . . . . . . 81.4.2 Replacementoraddingoptionalboardin873SmartRadar . . . . . . . . . . . . . . . . . . . . . . . . . . . 81.4.3 Replacementoraddingoptionalboardin877FDI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8

1.5 Optionalfunctionsinthismanual . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8

2 Spottemperaturemeasurement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 92.1 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 92.2 Commissioningofspottemperaturemeasurement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10

2.2.1 Spottemperaturesettings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 102.2.2 Additionaltemperaturesettingsfor877FDI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11

2.3 Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 122.3.1 Display . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 122.3.2 Dataitems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12

2.4 Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 132.4.1 Temperatureerrorrequest(itemEM) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 132.4.2 Temperaturestatusrequest(itemMQ) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 132.4.3 Temperaturepointervalue(itemVV) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14

3 Averagetemperaturemeasurement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 153.1 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 153.2 Commissioningofaveragetemperaturemeasurement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16

3.2.1 Averagetemperaturesettings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 163.2.2 Additionaltemperaturesettingsfor877FDI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19

3.3 Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 203.3.1 Display . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 203.3.2 Dataitems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20

3.4 Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 213.4.1 Temperatureerrorrequest(itemEM) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 213.4.2 Temperaturestatusrequest(itemMQ) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 213.4.3 Temperaturepointer(itemsVPandVV) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21

4 Waterbottommeasurement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 234.1 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23

4.1.1 Waterprobeversions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 234.1.2 Principleofmeasurement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24

4.2 Commissioningmeasurements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 244.2.1 Commissioningmeasurementswithroofsuspendedprobes . . . . . . . . . . . . . . . . . . . . . . . . 254.2.2 Commissioningmeasurementsforsidemountedprobes . . . . . . . . . . . . . . . . . . . . . . . . . . . 264.2.3 Waterprobesettings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27

4.3 Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 284.3.1 Display . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 284.3.2 Waterabove/belowprobewarning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 284.3.3 Dataitems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28

4.4 Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 294.4.1 Watererrorrequest(itemEW) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 294.4.2 HARTcommunicationerrors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 294.4.3 Waterlevel(ullage)statusbytes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 294.4.4 Waterbottompointer(itemsVPandVV) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30

Page 5: Instruction manual temperature, Water bottom and Analog outp.pdf

Tableofcontents

InstructionmanualTemperature,WaterbottomandAnalogoutputoptions Page5

5 Analogleveloutput . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 315.1 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31

5.1.1 HCUanalogoutputcharacteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 315.1.2 ICU_HPOanalogoutputcharacteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31

5.2 Commissioningofanalogleveloutput . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 335.2.1 Settingofanalogoutput973SmartRadarLTto“active” . . . . . . . . . . . . . . . . . . . . . . . . . . . . 335.2.2 Analogoutputsettings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 345.2.3 Calibrateanalogoutputcircuit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 355.2.4 Verifyoutputcurrent . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37

5.3 Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 385.3.1 Display . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 385.3.2 Dataitems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38

5.4 Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 395.4.1 Analogoutputerrorrequest(itemEA) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 395.4.2 Analogoutputstatusrequest(itemAQ) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 395.4.3 Analogoutputpointer(itemsVPandVV) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 405.4.4 Communicationboard(ICU_HPO)actualstatus(itemOA) . . . . . . . . . . . . . . . . . . . . . . . . . 405.4.5 Communicationboard(ICU_HPO)lastencounteredfatalerror(itemOF) . . . . . . . . . . . . . . 41

AppendixA ASCIItable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42AppendixB Configurationprocedurefor964WaterScout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43AppendixC Configurationprocedurefor765/766VITOwaterprobe . . . . . . . . . . . . . . . . . . . . . . . . . 46AppendixD Configurationofsidemountedwaterprobes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47AppendixE Partnumbers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49AppendixF Relateddocuments . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50

Index . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51

Page 6: Instruction manual temperature, Water bottom and Analog outp.pdf

Introduction

Page6

1 Introduction

1.1 HCUboard

TheoptionalHCUboardisusedinEnrafservogauges854ATG,854XTG,Enraf873SmartRadargaugeandEnrafIndicator877FDItointerfaceoptionalequipmentas:

spottemperatureelement; averagetemperatureelement; waterbottomprobe; pressuretransmitters.

andtoprovideforananalogleveloutput.

ThisboardinterfacestheEnraf762VITOInterfacefor:

averagetemperaturemeasurementwithEnrafVITOtemperatureprobe764; averagetemperaturemeasurementwithEnraf864MTT; waterbottommeasurementwithEnraf765VITOwaterprobe; averagetemperaturemeasurementwithintegratedwaterprobewithEnraf766VITOprobe.

viaHART input1.®

TheHART input2oftheHCUboardcanbeusedtoconnectpressuretransmitterforHIMS andHTGor® ™

vapourpressuremeasurement,ortoconnectasidemountedwaterprobe.

Notes:1 HTG(HydrostaticTankGauging)onlyapplicablewith877FieldDisplay&Interface.

HIMSisavailablewiththelevelgauges(servoandradar).

2 Standard,the762VITOInterfaceisconnectedtoHARTinput1andotherHART transmittersare®

connectedtoHARTinput2oftheHCUoptionboard.ItmustbeverifiedthatthemaximumvaluesforcurrentandpoweroftheHCUoptionboardHARTinput2circuitarenotexceedingthemaximumvaluesoftheconnectedHART transmitters.®

IfthevaluesofHARTinput2circuitaretoohigh,thenconnecttheotherHART transmitterstoHART®

input1andthe762VITOInterfacetoHARTinput2(onlypossiblewhenHARTinput1isavailable!).

ProducttemperaturecanalsobemeasuredwithaPt100spotelement(RTD)bytheoptionalboard.Theoptionforanalogleveloutput(4-20mA)isavailableindifferentcombinationswiththetemperature,waterbottomandpressuremeasurement.

1.2 ICU_HPIboard

TheoptionalICU_HPIboardisusedinEnraf973SmartRadarLTtointerfaceoptionalequipmentas:

spottemperatureelement averagetemperatureelement waterbottomprobe pressuretransmitters

Note:Analogleveloutputwiththe973SmartRadarLTisprovidedbytheoptionalICU_HPOboard.

Foradescriptionofthesefunctions,refertosection1.1.TheICU_HPIboardhasthesameinputfunctionsastheHCUboard;theonlydifferenceistheshapeoftheboard,whichmakesittofitinthe973SmartRadarLT.

Page 7: Instruction manual temperature, Water bottom and Analog outp.pdf

Introduction

InstructionmanualTemperature,WaterbottomandAnalogoutputoptions Page7

1.3 Overviewoffunctions

TheHCU/ICU_HPIoptionboardhasthefollowinghardwarechannels:

SPOTinput: forspottemperatureelementPt100 HARTinput1: for762VITOInterface HARTinput2: forHART pressuretransmittersand/orexternalwaterbottomprobe®

4-20mAoutput: foranalogleveloutput(onlywithHCUoptionboard)

Thehardwarecombinations,togetherwithsoftwareemulationsgivesintotal8differentmodelsaccordingtothetablebelow:

Salescodeforoption

FunctionwithHCUandICU_HPIoptionboard Emulationmode

B SpottemperaturePt100 TPU-2/HSU

C VITOtemperatureand/orwaterprobe HPU

J VITOtemperatureand/orwaterprobe+HARTdevice(s) HPU

U SpottemperaturePt100+HARTdevice(s) HSU

V Analogleveloutput MPU

W Analogleveloutput+VITOtemperatureand/orwaterprobe HCU

X Analogleveloutput+VITOtemperatureprobe MPU

Y HCUAnalogleveloutput+SpottemperaturePt100+VITOtemperatureand/orwaterprobe+HARTdevice(s)

Notes:1 Optioncodes:V,WandXarenotavailablewiththe973SmartRadarLT

(analogleveloutputisprovidedbytheICU_HPOoptionboard).2 PleasenotethatwithoptioncodeYinthe973SmartRadarLT,theanalogleveloutputisprovidedby

theICU_HPOoptionboard.3 OptioncodeYisnotavailableinthe854XTGservogaugeand877FDI.4 OptioncodeUisonlyavailableinthe854XTGservogaugeand877FDIwithoutconnectionfor977TSI5 HARTdevicescanbe:- HART pressuretransmittersforHIMS/HTGconfigurationorvapourpressure®

measurement;- HART waterbottomsensorse.g.Sidemountedwaterprobe.®

6 WithsalescodeY(allHCUfunctions),thespottemperaturemeasurementisdisablediftheVITOtemperature(andwater)probeispresent.

1.4 HCUcompatibility

TheHCUboardcanbeusedtoreplaceanexistingoptionalboardinthe854,873and877gauges.However,itrequiressomecheckingifmoreboardsintheinstrumentmustbeupdatedorexternalequipmentmustbereplaced.

Page 8: Instruction manual temperature, Water bottom and Analog outp.pdf

Introduction

Page8

TheHCUboardcanbeusedtoreplacethefollowingoptionalboards: TPU(-2)board (restrictedtoPt100RTD’sonly) MPUboard (foraveragetemperaturemeasurement,restrictedtoMTTorVITOprobesonly) HPUboard (foraveragetemperaturemeasurement,restrictedtoMTTorVITOprobesonly) HSUboard (fortemperaturemeasurement,restrictedtoPt100RTD’sonly)

Note:ReadcarefullytheinstallationguideoftheHCUboardbeforestartingtoreplacetheexistingoptionboard.

1.4.1 Replacementoraddingoptionalboardin854ATGor854XTGservogauges

TheHCUoptionalboardrequiresanXPU-2boardinthe854ATGand854XTGservogauges.IfthereisnoXPU-2boardinstalled,thentheinstalledXPU(orXPU-1)boardmustbereplacedbyanXPU-2board.

Notes:1 WhentheHCUboardisusedtoreplaceanoptionalboardwithaveragetemperaturemeasurement,

pleasenotethefollowing:The863MRTwith862MIRorthe864MTTwith862MITtemperatureconnectioncannotbemaintained. The864MTTcanbeconnectedtothe762VITOInterfacewhichinterfacestotheHCUboard. The863MRTcannotbeconnectedtothe762VITOInterface.

2 TheoptionaldatatransmissionchannelontheXPU-2(i.s.channelfor977TSIorRS-232C/RS-485channel)isonlypossiblewhenbackplane-2isinstalled.Backplane-2isstandardinstalledininstruments 854ATGwithseriesnumber:854-20-400andhigher; 854XTGwithseriesnumber:894-02-001andhigher.

1.4.2 Replacementoraddingoptionalboardin873SmartRadar

TheHCUoptionalboardcanbeinstalledinthe873SmartRadarwithoutanyproblem.RefertotheNote1insection1.4.1.

1.4.3 Replacementoraddingoptionalboardin877FDI

TheHCUoptionalboardcanbeinstalledinan877FDIwhenthereisanXPUorXPU-1board.However,beinformedthatwaterbottommeasurementisnotpossiblewithVITOprobeandSidemountedwaterprobe.Ifthisfunctionisrequired,thentheinstalledXPU(orXPU-1)boardmustbereplacedbyanXPU-2board.RefertoNote1insection1.4.1.

Note:TheoptionaldatatransmissionchannelontheXPU-2(i.s.channelfor977TSIorRS-232C/RS-485channel)isonlypossiblewhenbackplane-2isinstalled.Backplane-2isstandardinstalledinindicators877FDIwithseriesnumber:877-17-001andhigher;

1.5 Optionalfunctionsinthismanual

Thisinstructionmanualdescribestheoptionalfunctionsfor: spottemperaturemeasurement averagetemperaturemeasurement waterbottommeasurement analogleveloutput

TheoptionalfunctionsforHIMS,HTGandvapourpressuremeasurementaredescribedintheinstructionmanual:HIMS/HTGandvapourpressure(P3)measurement.

Page 9: Instruction manual temperature, Water bottom and Analog outp.pdf

Spottemperaturemeasurement

InstructionmanualTemperature,WaterbottomandAnalogoutputoptions Page9

2 Spottemperaturemeasurement

2.1 Introduction

AstandardPt100spotelement(RTD)canbemeasuredanditstemperatureisinterpretbytheHCUandICU_HPIboardasproducttemperature.

Thetemperaturemeasurementisintrinsicallysafe,certifiedEExiaIIB.

PrincipleofoperationThetemperaturemeasurementisbasedona3-wireRTDconfiguration.OnlytheICU_HPIboardhastheoptionfora4-wireRTDconfiguration.

Theresistancemeasurementfor3-wireconfigurationisperformedinthefollowingsteps:

Thespotelementismeasured,includingthecableresistance Thecableresistanceismeasuredseparately,andsubtractedfromtheelementresistancetoavoid

influenceofthecablingonthetemperaturemeasurement Next,thesystemconstantisdetermined.Thisisdonebymeasuringanaccuratereferenceresistance

(R )±0.01%+2ppm/°C(-40÷85°C)ref InordertochecktheR ,atestresistor(R )ismeasured.Thisresistorhasthesameaccuracyastheref test

referenceresistor

Thesefourmeasurementsareperformedwithandwithoutcurrenttocompensateforanythermooroffsetvoltageinthemeasuringcircuit.

Thetemperaturedataisdisplayed(whenadisplayispresent)asproducttemperatureandtransmittedtothehost.

Page 10: Instruction manual temperature, Water bottom and Analog outp.pdf

Spottemperaturemeasurement

Page10

2.2 Commissioningofspottemperaturemeasurement

ThecommissioningoftheoptionalspottemperaturepartoftheHCUorICU_HPIboardshouldbeperformedafterthebasiccommissioningofthelevelgaugeorindicator.

2.2.1 Spottemperaturesettings

Item Name Description

W2= Protectionlevel2 Enterprotectionlevel2.

TD= Temperaturedimension Onecharacter;either‘C’or‘F’.DefaultsettoC.C : degreesCelsiusF : degreesFahrenheit

Bothdimensionshavethesameformat.

MN= Elementconfiguration Twodigits(default:16)whichmustbeseteitherto:03 for3wireRTDconfigurationor04 for4wireRTDconfiguration(ICU_HPIboardonly).

Note:Ifa4wireRTDconfigurationisused,strapST4ontheICU_HPIboardmustbeplacedtothecorrectposition(refertofig.2.1).

MO= RTDposition FormataccordingtoitemLD.MOrepresentsheightoftheRTDelementwithrespecttothezeropointofthelevelgauge.Ifthemeasuredleveldropsbelowthisheightthefollowingtwoactionstakesplace:1) Thecorrespondingstatusbit(bit3)issetinstatusbyte1

ofitemAP(temperaturerequest);2) Thetemperaturestatusontheinstrumentdisplay(ifapplicable)

issetto‘LR’.

MI= Switchhysteresis FormataccordingtoitemLD.Default:+000.1000(m).ItemMIisaswitchhysteresisaroundtheRTDpositionitemMO.

TU= Temperaturestatusconversion Onecharacter;default‘T’.Thischaracteristransmittedinthetemperaturestatusbytetothehostincaseof:- levelbelowRTDposition(itemMO)- invalidlevelreadingIfrequired,thisitemcanbesettoanothercharacter.

EX Exit Exitprotectionlevel.

Page 11: Instruction manual temperature, Water bottom and Analog outp.pdf

Spottemperaturemeasurement

InstructionmanualTemperature,WaterbottomandAnalogoutputoptions Page11

Figure2.1 Strapfor3-or4-wireconfigurationonICU_HPIboard

2.2.2 Additionaltemperaturesettingsfor877FDI

Item Name Description

W2= Protectionlevel2 Enterprotectionlevel2.

OB= Optionalboard*) ThreeASCIIcharacters.ThisiteminformstheXPU(andXPU-1)whatoptionboardisinstalled.Ithastobesetto‘HPU’.

EG= Enabletemperature OneASCIIcharacter;either‘D’or‘E’.Withthisitemcanbetransmission*) selectedifthe877FDIshallansweronatemperaturerequest

(C-record),addressedtotheconnectedlevelgauge.E : transmissionoftemperaturerecordenabledD : transmissionoftemperaturerecorddisabled

Note:WhenitemEGissetto‘E’,makesuretherelatedlevelgaugehasnotemperatureoptioninstalled.

TF= Temperaturesourceselection OneASCIIcharacter;either‘I’or‘E’.Thisitemselectsifthereisatemperaturemeasurementinsidetheindicator(Internal),orthetemperaturehastobefetchedfromtheEnraffieldbus(External).

I : Internal(HCUoptionalboardinstalled)E : External

IM= Indicatormode OneASCIIcharacter.WithXPU-2,the877FDIcanbesetinstandalonetemperaturegaugemode.ThenitemIMhastobesetto‘T’.

EX Exit Exitprotectionlevel.

*) ThisitemisnotimplementedintheXPU-2.

Page 12: Instruction manual temperature, Water bottom and Analog outp.pdf

Spottemperaturemeasurement

Page12

2.3 Operation

2.3.1 Display

Foroperationofthedisplayandtheinformationonit(ifapplicable),refertotheinstructionmanualoftherelatedlevelgaugeorindicator.Below,onlyanoverviewisgivenwhichdisplayformatsgivesinformationaboutthespottemperaturemeasurement.

Displayformat Displayedinformation

AD

ProductlevelandtemperatureProducttemperatureandstatus

2.3.2 Dataitems

Thetablebelowlistsanumberofdataitems.Theycontainmeasureddata,verificationdataanderrordata.Theverificationdatacanbeusedtochecktheresultsofcertainstepsinthemeasuringsequence.

Thetemperaturestatusindicatesthevalidityofthemeasureddata.Theerrordataprovideslowlevelerrorinformationaboutthetemperaturemeasurement(refertosection2.4).

Item Description

AP Measuredtemperature(dimensionaccordingtoitemTD);

MU Measuredtestresistance(floatingpointformat);

MQ

MeasureddatathevalueisprecededbyfourcharactersfromthetemperaturestatusitemMQ.

mustbe:166.5Ω±0.03%.Temperaturestatusrequest(refertosection2.4.2).

VV Verificationdata Refertodescriptionatsection2.4.3.

EMFHH0

Diagnosticdata ErrorHCU/ICU_HPIrequest(refertosection2.4.1).FatalHCU/ICU_HPIerrorsLastfatalHCU/ICU_HPIerror

Page 13: Instruction manual temperature, Water bottom and Analog outp.pdf

Spottemperaturemeasurement

InstructionmanualTemperature,WaterbottomandAnalogoutputoptions Page13

2.4 Troubleshooting

2.4.1 Temperatureerrorrequest(itemEM)

ThisitemcontainsthemostrecenttemperatureerrorencounteredbytheoptionalHCU/ICU_HPIboard.

xx00 Noerror,valueatinitialisationxx10 Countererror Hardwareerror.Resetinstrument;iferrorpersist,replaceHCUorICU_HPIboardxx15 UTItime-outxx29 R_cableerror ResistanceofB-andC-wiretoohigh(loopresistance:≤24Ω)xx30 Connectionerror CheckthewiringconnectionsofRTDtoinstrumentxx34 R error Hardwareerror.Resetinstrument;iferrorpersist,replaceHCUorICU_HPIboardtest

xx70 Wrongelementconfigurationspecified CheckitemMN(mustbesetto‘03’or‘04’)xx98 Notemperaturesourcesfound NoRTD(andnoVITOtemperatureprobe)connectedxx99 Spotoptionprintnotinstalled ChangeHCUorICU_HPIboardforthecorrecttype

xx: 28forHSU/TPU-2emulation30forHCUemulation

2.4.2 Temperaturestatusrequest(itemMQ)

Thetemperaturestatusrequestitemcontainsfourstatusbytes(Byte0,Byte1,Byte2,Byte3)fromtheoptionalHCU/ICU_HPIboard.Fordecoding,refertotheASCIItableinappendixA.

Statusbyte0:always‘0‘

Statusbyte1: Statusbyte2:bit 0: GeneralHCU/HPItemperaturefail bit 0: Lastvalidlevelused 1: Failinspottemperaturereading 1: Manuallevelused 2: 1 2: Leveltime-out 3: ProductlevelbelowRTDposition 3: 0 4: 0 4: 0 5: 0 5: Temperatureoutofrange

6: 1 6: 17: 0 7: 0

Statusbyte3:bit 0: Nopreviousstorecommand1-5: 0

6: 17: 0

Note:Onlythebitswhicharesetto‘1’haveanactivestatus.

Page 14: Instruction manual temperature, Water bottom and Analog outp.pdf

Spottemperaturemeasurement

Page14

2.4.3 Temperaturepointervalue(itemVV)

Bymeansofthevaluepointer(itemVP)avectorcanbeloadedtotheHCUorICU_HPIoptionboard.Next,withitemVV,theselecteddataisreturned.ItemVPconsistsof4positions,inthemiddleseparatedbya‘.’or‘,’:vw.xy(orvw,xy).Thevaluesforthevaluepointerarelistedinthetabletogetherwiththeobtaineddata.

vw , xy Selecteddata Example/Dimension

00 , 00 HCU/ICU_HPIEmulation&Function VV=HCUHCAOST--PR

00 , 01 Configurationbootcode VV=HCUCONFIG:3F

00 , 02 HCU/ICU_HPIhardwareversion VV=HWVERSION:0000 , 03 Bootcodesoftwareversion VV=BOOTSWVERS:01

01 , 00 Measuredspotresistance (floatingpointformat)01 , 01 Calculatedspottemperature (floatingpointformat)01 , 02 Measuredcableresistance (floatingpointformat)01 , 50 Temperatureupdatecounter

Emulation: MPU,HSU,HPU,HCUFunction: HC: HARTchannelinstalled

AO: analogoutputST: spottemperatureMT: VITOaveragetemperatureWS: externalwaterbottomprobeWT: VITOwaterbottomprobePR: pressuretransmitters

Salescodeoption: B bootcode: 01U 25Y 3F

ΩaccordingtoitemTD

Ω

Item Name Description

VP= Temperaturevaluepointer Temperaturevaluepointer;format:2digits,separator,2digits (refertotableabove).

Example: VP=01.00:valuepointerloadedtorequestthemeasuredspotresistance.

VV Temperaturepointervalue Temperaturepointervalue.ThisitemholdsthevaluerequestedbyitemVP(refertotableabove).Example: therequestedmeasuredspotresistance

(standardfloatingpointformat).

Page 15: Instruction manual temperature, Water bottom and Analog outp.pdf

Averagetemperaturemeasurement

InstructionmanualTemperature,WaterbottomandAnalogoutputoptions Page15

Figure3.1 VITOtemperatureprobes&MTT

3 Averagetemperaturemeasurement

3.1 Introduction

AnEnrafaveragetemperatureprobecanbe:

• a764VITOtemperatureprobe;• a766VITOwaterandtemperatureprobe;• a864MTT.

Dependingonthetypeof764VITOtemperatureprobe,thereare15or16spotelements(thermocouples)equallyspacedoverthemeasuringrange.

Thetemperaturemeasurementisbasedonthermocouples(spots)andonePt100referenceresistor.

Themeasuringrangeisdefinedas:distancefromreferenceresistortopositionhighestelement.

Refertofigure3.1.

• A Thismodelhasthereferenceresistorlocatedclosetothelowerendoftheprobe.Thereare16spots,equallydividedoverthemeasuringrange;

• B Here,thereferenceresistorisplacedat1m(3ft3)fromthelowerendoftheprobe.Onespotislocatedclosetothelowerendoftheprobetomeasuretemperatureatlowlevels.Withthismodel,thereare15spots,equallydividedoverthemeasuringrange;

• C Thisisa766VITOtemperatureandwaterprobe.Fortemperaturemeasurement,thismodelisequaltoB;

• D Thismodelof766VITOtemperatureandwatersensorhas16spots,equallydividedoverthemeasuringrange.Hence,thereisnospotatthelowerendofthewaterprobe.

UsingtheEnrafaveragetemperatureprobes(764VITOtemperatureprobe,766VITOwaterandtemperatureprobeorthe864MTT)a762VITOInterfaceisrequired.This762VITOInterfaceispoweredbythelevelgauge(or877FDI)overthesametwowiresastheHART communicationtakesplacetothelevelgauge.®

Inthelevelgauge,or877FDI,thetemperatureiscalculated.Thetemperatureofallspotsimmersedintheliquid,areaveragedforproducttemperaturecalculation.Allspotsabovetheliquidsurfaceareusedtocalculatetheaveragegastemperature.

Withthetemperature(andwater)probemodels,whichhaveaspotbelowthereferenceresistor,thatspottemperatureisnotusedintheaverageproducttemperaturecalculations.Itstemperatureisonlyusedwhentheproductleveldropsbelow1m(locationofreferenceresistor)toprovidetheuserwithatemperaturevalue.However,withstatus:‘levelexceedslowestspotelement’;itemMQ,bit3ofbyte1isset).

Page 16: Instruction manual temperature, Water bottom and Analog outp.pdf

Averagetemperaturemeasurement

Page16

3.2 Commissioningofaveragetemperaturemeasurement

Thewiringsequenceofallbluethermocouplewiresisonlymeasuredonceatstart-upandtheinformationisstoredintheHCU/ICU_HPImemory.Thetimerequiredtocompleteall15thermocouplemeasurementsafterpoweringuptheinstrumentisapproximately2minutes.

ThecommissioningoftheoptionalaveragetemperaturepartoftheHCUorICU_HPIboardshouldbeperformedafterthebasiccommissioningofthelevelgaugeorindicator.

3.2.1 Averagetemperaturesettings

Beforeprogrammingthetemperaturedata,thesensitivelengthandtheoffsetofthetemperatureprobemustbeknown.

Thesensitivelengthisequaltothemeasuringrange.Standard,themeasuringrangesare:

for764VITOtemperatureprobe(modelcode:....764B<ol><he>) :overalllength-700mm; for864MTT :overalllength-700mm; forotherVITOtemperature(andwater)probe :overalllength-1700mm.

Other(smaller)measuringranges(sensitivelengths)arepossible;checkonidentificationlabeloftheVITOprobe(orMTT)forthepositionofthehighestelement(last4digits;units:cm).

Theoffsetisthedistancefromthelowestelementtothetank’szeropoint(datumplate).The764VITOtemperaturesensorand766waterandtemperaturesensorcanhavethelowestelementondifferentplaces.Thisisidentifiedontheinstrumentlabel:

....764A<ol><he> lowestelementat0.065mfromlowerendofprobe; ....764B<ol><he> lowestelementat0.065mfromlowerendofprobe; .A..766B<ol><he> lowestelementat0.065mfromlowerendofprobe; .A..766A<ol><he> lowestelementat1mfromlowerendofprobe.

Withthe864MTT,thelowestelementisat0.065mfromlowerendofprobe.

Note:Inthemodelcodegivenaboveadot‘.’representsanycharacter,thenotation<ol>means:overalllength(4positions)andthenotation<he>means:positionofhighestelement(4positions).Thenotation<sl>means:sensitivelength(4positions)andisonlyusedwith864MTT.

ThepositionofthelowestelementcanalsobeverifiedbyrequestingtheVITOdevicetype&s/wversionbymeansofitemsVPandVV,providedyouknowifa764VITOsensorisconnected,ora864MTT.

Refertothetablebelowandtosection3.4.3howtoobtaindatawiththetemperaturepointeritems:

ItemVP ItemVV sensormodelcode

VP=03.10 VV:764PTTC10 ....764A<ol><he>

VP=03.10 VV:766PTTCW10 .A..766B<ol><he>

VP=03.10 VV:864PTTC10 ....764B<ol><he>VV:864PTTCW10 .A..766A<ol><he>VV:864PTTC10 ....864.<ol><sl>

Page 17: Instruction manual temperature, Water bottom and Analog outp.pdf

Averagetemperaturemeasurement

InstructionmanualTemperature,WaterbottomandAnalogoutputoptions Page17

Figure3.2 Tankandtemperatureprobedata

Page 18: Instruction manual temperature, Water bottom and Analog outp.pdf

Averagetemperaturemeasurement

Page18

Refertofigure3.2.

Item Name Description

W2= Protectionlevel2 Enterprotectionlevel2.

TD= Temperaturedimension Onecharacter;either‘C’or‘F’.DefaultsettoC.C: degreesCelsiusF: degreesFahrenheit

Bothdimensionshavethesameformat.

MK= Sensitivelengthtemperature FormataccordingtoitemLD(default:+030.0000).probe Refertothedescriptioninsection3.2.1aboutthesensitivelength

(measuringlength)ofthetemperatureprobe.EnterthatvalueinitemMK.

MO= Temperatureelementoffset FormataccordingtoitemLD(default:+000.0000).ItemMOrepresentsthedistancefromtankzero(datumplate)tothelowestelement(spot)inthesensor.Thelowestelementinthesensordependsonthetypeoftemperaturesensor.Refertotheinstrumentlabelandfigure3.2.ThelocationofthelowestelementcanalsobefoundbyrequestingitemVV(withVP=03.10).Refertosection3.4.3.

MI= Switchhysteresis FormataccordingtoitemLD(default:+000.1000m).ThedistanceMIisahysteresisaroundtheswitchingpointofthetemperatureelements.

MP= Productimmersiondepth FormataccordingtoitemLD(default:+000.5000m).ThedistanceMPspecifiestheminimumrequiredliquidlevelaboveathermocouplebeforeitistakenintheaverageproducttemperaturecalculation.

MG= Gasimmersiondepth FormataccordingtoitemLD(default:+000.5000mfor854/873/973and+000.1000mfor877).ThedistanceMGspecifiestheminimumrequireddistancebelowathermocouplebeforeitistakenintheaveragegastemperaturecalculation.

TU= Temperaturestatusconversion Onecharacter(default:‘T’).Thisitemisusedtoindicatethetemperaturestatuscharacterincaseofareducedornotguaranteedtemperatureaccuracy.Thisisthecasewhenthetemperaturestatusis:

- outofspecifiedtemperaturerange- exceedingdifferentialtemperaturerange- lastvalidlevelused- manuallevelused- levelbelowlowesttemperatureelement

Ifrequired,thisitemcanbesettoanothercharacter.

EX Exit Exitprotectionlevel2.

Page 19: Instruction manual temperature, Water bottom and Analog outp.pdf

Averagetemperaturemeasurement

InstructionmanualTemperature,WaterbottomandAnalogoutputoptions Page19

Withthe764VITOtemperatureprobesandalsowithan864MTT,itmightberequiredtodisablethelowestspotelementfromtheaveragetemperaturecalculation.ThatcanbedonebysettingthefirstpositioninitemMWto‘F’.Infact,withitemMWanyspottemperatureelement(ormorespots)canbedisabledfromaveragetemperaturecalculation.

Item Name Description

W2= Protectionlevel2 Enterprotectionlevel2

MW= MTTwiringconnection Sixteenhexa-decimalcharacters;default:0000000000000000.Whenone(ormore)oftheelementsmustbedisabledfromaveragetemperaturecalculation,setthedesiredpositionto‘F’.Forinstance,todisablelowestspotelement:

MW=F000000000000000Note:

WhenenteringitemMWwiththePortableEnrafTerminal,thedisplaywillbeclearedafterenteringthe15 character.th

Continuewithenteringthelastcharacterandpressreturn.All16enteredcharacterswillberepeatedatthetoplineofthePET.

EX Exit Exitprotectionlevel2

3.2.2 Additionaltemperaturesettingsfor877FDI

Item Name Description

W2= Protectionlevel2 Enterprotectionlevel2

OB= Optionboard*) ThreeASCIIcharacters.ThisiteminformstheXPUwhatoptionboardisinstalled.Thatcanbe:

MPU : forHCUoptionboardinMPUemulationmodeHPU : forHCUoptionboardinHPUemulationmode

EG= Enabletemperature OneASCIIcharacter;either‘D’or‘E’.Withthisitemcanbetransmission*) selectedifthe877FDIshallansweronatemperaturerequest

(C-record),addressedtotheconnectedlevelgauge.E : transmissionoftemperaturerecordenabledD : transmissionoftemperaturerecorddisabled

Note:WhenitemEGissetto‘E’,makesuretherelatedlevelgaugehasnotemperatureoptioninstalled.

TF= Temperaturesourceselection OneASCIIcharacter;either‘I’or‘E’.Thisitemselectsifthereisatemperaturemeasurementinsidetheindicator(Internal)ortobefetchedfromtheEnraffieldbus(External).

I : Internal(HCUoptionboardinstalled)E : External

EX Exit Exitprotectionlevel2.

*)ThisitemisnotimplementedintheXPU-2.

Page 20: Instruction manual temperature, Water bottom and Analog outp.pdf

Averagetemperaturemeasurement

Page20

3.3 Operation

3.3.1 Display

Foroperationofthedisplayandtheinformationonit(ifapplicable),refertotheinstructionmanualoftherelatedlevelgaugeorindicator.Below,onlyanoverviewisgivenwhichdisplayformatsgivesinformationabouttheaveragetemperaturemeasurement.

Displayformat Displayedinformation

ACD

ProductlevelandaverageproducttemperatureAveragegastemperatureandstatusAverageproducttemperatureandstatus

3.3.2 Dataitems

Thetablebelowlistsanumberofdataitems.Theycontainmeasureddata,verificationdataanderrordata.Theverificationdatacanbeusedtochecktheresultsofcertainstepsinthemeasuringsequence.Thetemperaturestatusindicatesthevalidityofthemeasureddata.Theerrordataprovideslowlevelerrorinformationaboutthetemperaturemeasurement(refertosection3.4.).

Item Description

AGAPMQMU

U0-UFV0-VF

Measured/ Averagegastemperaturecalculateddata Averageproducttemperature

Temperaturestatusrequest(refertosection3.4.2)Measuredtestresistance(floatingpointformat);mustbe:166.5Ω±0.03%Calculatedspotpositions(seebelow)Spottemperatures(seebelow)

VVRW

Verificationdata Refertodescriptionatsection3.4.3Thermocouplewiringconnectionsequence

EMFHF0

Diagnosticdata ErrorHCU/ICU_HPIrequest(refertosection3.4.1)FatalHCU/ICU_HPIerrorsLastfatalHCU/ICU_HPIerror

ItemV0isthetemperatureofthelowestspotelement.ThecalculatedspotpositionitemU0correspondswithitemV0.Refertofigure3.2tolocatethelowestspot(L)witheachparticulartemperatureprobemodel.

Page 21: Instruction manual temperature, Water bottom and Analog outp.pdf

Averagetemperaturemeasurement

InstructionmanualTemperature,WaterbottomandAnalogoutputoptions Page21

3.4 Troubleshooting

3.4.1 Temperatureerrorrequest(itemEM)

ThisitemcontainsthemostrecenttemperatureerrorencounteredbytheHCU/ICU_HPIboard.

xx00 Noerror,valueatinitializationxx11 NoreplyoninitialHARTcommands Communicationerror.Checkconnectionlevelgauge-762VITOInterface,orchange762

VITOInterfaceorHCU/ICU_HPIboardxx50 Pt100(orspot0)error BrownwireconnectedtoCN1A-1(ororangewireconnectedtoCN2B-1)notconnectedxx51 Spot1(orPt100)error BluewiretoCN2B-1(orbrownwiretoCN1A-1)notconnectedxx52 Spot2error BluewiretoCN2A-2notconnected: : :xx64 Spot14error BluewiretoCN5A-2notconnectedxx65 Spot15error YellowwiretoCN5A-1notconnectedxx70 Sub-systemerror Datafrom762VITOnotvalid.Resetinstrument;iferrorpersist,replace762VITOInterfacexx71 Wrongprobeconnection ThermocouplewiresofVITOsensorconnectedwrongly(blueandyellowwires)xx77 WrongPt100connection BrownandredwiresofVITOsensorconnectedwronglyxx80 R error Measurementontestresistorfailed.Resetinstrument;iferrorpersist,replace762VITOtest

xx84 Standarddeviationtoolarge EMCinfluence(checkcableshields)ordefective762VITOInterfacexx92 Nodataavailable Communicationerrorbetween762VITOInterfaceandlevelgauge.Checkwiring;replace

762VITOInterfaceorHCU/ICU_HPIboardxx98 Notemperaturesourcesfound NoVITOtemperatureprobe(andnoRTD)connected

xx: 22forMPUemulation Witherrorcodesxx50toxx65,connectornumbersarementioned.24forHPUemulation RefertoInstallationguide762VITOInterface&764,765or766VITO30forHCUemulation temperatureand/orwaterbottomprobeforlocationoftheseconnectors.

3.4.2 Temperaturestatusrequest(itemMQ)

Thetemperaturestatusrequestitemcontainsfourstatusbytes(Byte0,Byte1,Byte2,Byte3)fromtheoptionalHCU/ICU_HPIboard.Fordecoding,refertotheASCIItableinappendixA.

Statusbyte0:Containsthecharacters‘0’÷‘F’,indicatingthehighestimmersedspotelementofthetemperatureprobe.Atstartup:’I‘.

Statusbyte1: Statusbyte2:bit 0: Generaltemperaturefail bit 0: Lastvalidlevelused

1: Failinaverageproducttemperature 1: Manuallevelused2: Failinaveragegastemperature 2: Leveltimeout3: Levelexceedslowestspotelement 3: Devicenotcalibrated4: Levelexceedshighestspotelement 4: Exceedingdifferentialtemp.range5: Spotelementfail(oneormorespotsdefect) 5: Outofspecifiedtemperaturerange6: 1 6: 17: 0 7: 0

Statusbyte3:bit 0: Nopreviousstorecommand1-5: 0

6: 17: 0

Note:Onlythebitswhicharesetto‘1’haveanactivestatus.

3.4.3 Temperaturepointer(itemsVPandVV)

Bymeansofthevaluepointer(itemVP)avectorcanbeloadedtotheHCUorICU_HPIoptionboard.Next,withitemVV,theselecteddataisreturned.ItemVPconsistsof4positions,inthemiddleseparatedbya‘.’or‘,’:vw.xy(orvw,xy).Thevaluesforthevaluepointerarelistedinthetabletogetherwiththeobtaineddata.

Page 22: Instruction manual temperature, Water bottom and Analog outp.pdf

Averagetemperaturemeasurement

Page22

vw , xy Selecteddata Example/Dimension

00 , 00 HCU/ICU_HPIEmulation&Function VV=HCUHCAOMT--PR

00 , 01 Configurationbootcode VV=HCUCONFIG:3F

00 , 02 HCU/ICU_HPIhardwareversion VV=HWVERSION:0000 , 03 Bootcodesoftwareversion VV=BOOTSWVERS:01

02 , 00 CalculatedtemperatureofspotconnectedtoCN1A-1 (floatingpointformat)02 , 01 CalculatedtemperatureofspotconnectedtoCN2B-1 (floatingpointformat): : :02 , 15 CalculatedtemperatureofspotconnectedtoCN5A-1 (floatingpointformat)02 , 20 MeasuredPt100resistance (floatingpointformat)02 , 25 Standarddeviation (floatingpointformat)02 , 26 V (floatingpointformat)02 , 27 LeakcurrentI (floatingpointformat)02 , 28 LeakcurrentI (floatingpointformat)

03 , 01 ErrorcountersHARTaddresses3,4and5

03 , 09 DetectedHARTdeviceaddresses (5forVITOInterface)03 , 10 InitialdetectedVITOdevicetype&s/wversion

03 , 11 RealactivefunctionsofVITOInterface(refertodescriptionofVP=03,10)03 , 12 ActualexecutedHARTcommandsfrom762VITOInterface03 , 20 Averagingconstant762VITOInterface (floatingpointformat)

Emulation: MPU,HSU,HPU,HCUFunction: HC: HARTchannelinstalled

AO: analogoutputST: spottemperatureMT: VITOaveragetemperatureWS: externalwaterbottomprobeWT: VITOwaterbottomprobePR: pressuretransmitters

Salescodeoption: C bootcode: 0AJ 2EW 1AX 12Y 3F

test

1

2

(762VITOInterfacehasHARTaddress5)

Description: 764: 764VITOtemperatureprobewithPt100referenceresistorat1mandspotclosetoprobe’send

766: 766VITOwaterandtemperatureprobewithspotclosetoprobe’send

864: 764VITOtemperatureprobewithPt100referenceresistorandlowestspotclosetotheprobe’send.766VITOwaterandtemperatureprobewithPt100referenceresistorandlowestspotat1m864MTT.

PT: Pt100TC: thermocouplesW: waterprobe10: softwareversion1.0

accordingtoitemTDaccordingtoitemTD

accordingtoitemTDΩ

VAA

VV=0000:0000:0013

VV=----5---------VV=766PTTCW10model:....764A<ol><he>

model:.A..766B<ol><he>

model:....764B<ol><he>

model:.A..766A<ol><he>

model:....864.<ol><sl>

VV=766PTTC

Item Name Description

VP= Temperaturevaluepointer Temperaturevaluepointer;format:2digits,separator,2digits (refertotableabove).

Example: VP=02.20:valuepointerloadedtorequestthePt100elementresistance.

VV Temperaturepointervalue Temperaturepointervalue.ThisitemholdsthevaluerequestedbyitemVP(refertotableabove).Example: therequestedPt100elementresistance

(standardfloatingpointformat).

Page 23: Instruction manual temperature, Water bottom and Analog outp.pdf

Waterbottommeasurement

InstructionmanualTemperature,WaterbottomandAnalogoutputoptions Page23

Figure4.1 VITOwaterprobes,Sidemountedwaterprobe&964WaterScout

4 Waterbottommeasurement

4.1 Introduction

Thewaterbottomprobeisbasedonacapacitivemeasurementprinciple.Theprobeisoneplateofthecapacitorandearthed,electricallyconductingpartsaswaterandthetankshell,istheotherplate.Achangeinwaterlevelisdetectedbythewaterbottomprobeasachangeincapacitance.

4.1.1 Waterprobeversions

Therearethreedifferentwaterprobeversionswhichcanbeinterfaced:• the765VITOwaterprobe;• the766VITOwaterandtemperatureprobe;• theexternalHART waterbottomprobe(Sidemountedwaterprobeor964WaterScout).®

The765VITOwaterprobeand766VITOwaterandtemperatureprobeareconnectedtothe762VITOInterface,whichisconnectedtotheHCUboardorICU_HPIboard.TheexternalwaterbottomprobeisconnectedtoHARTinput2(sameinputwherepressuretransmittersareconnected).

Refertofigure4.1.A) 765VITOwaterprobe

Canbedeliveredinthreesensitivelengthsforthewatermeasurement:0.5m,1.0mand2.0m.B) 766VITOwaterandtemperatureprobe

Thereisonesensitivelengthforthewatermeasurement:0.5m.C) 964WaterScout(previousmodel)

WiththeintroductionoftheVITOfamily,the964WaterScouthasbecomeobsolete.Itcan,however,beconnectedtotheHCU/ICU_HPIoptionboard

D) Sidemountedwaterprobe

Page 24: Instruction manual temperature, Water bottom and Analog outp.pdf

Water level PV PV LRVPV URV PV LRV

× sensitive length probe water probe bottom position

LW MX VRVT VR

× WP WB

Waterbottommeasurement

Page24

4.1.2 Principleofmeasurement

Whencorrectlycalibrated,thecapacitancevaluegiveninPVLRV(PrimaryVariableLowerRangeValue)isthecapacitancemeasuredbytheprobewhennowaterispresent(sensitivepartofprobecompletelyimmersedinproduct).ThecapacitancevaluegiveninPVURV(PrimaryVariableUpperRangeValue)isthecapacitancemeasuredbytheprobewhenthesensitivepartofprobecompletelyimmersedinwater.

Note:The765and766VITOwaterprobesusesitemsVRandVTtostoretheminimumandmaximumcapacitancevalues.

Themeasuredcapacitancebythewaterprobehasalinearfunctionwiththewaterlevel.Hence,thewaterleveliscalculatedas:

where: PV =themeasuredcapacitancebythewaterprobe;withVITOwatersensor,itemMXisusedPVLRV =theminimumcapacitance(0%water);withVITOwaterprobe,itemVRisusedPVURV =themaximumcapacitance(100%water);withVITOwaterprobe,itemVTisused

or,

where: LW =waterlevelWP =waterprobelengthWB =waterprobebottomposition

4.2 Commissioningmeasurements

Thepurposeofthesecalibrationmeasurementsistodeterminethewaterprobeoffsetandacontrolmeasurementforthewaterlevel.

Withthesemeasurementstheproductlevelisusedasahorizontallinebetweenthepointwherethetankzeropointislocatedandthepointwherethewaterprobeisinstalled.

Page 25: Instruction manual temperature, Water bottom and Analog outp.pdf

Waterbottommeasurement

InstructionmanualTemperature,WaterbottomandAnalogoutputoptions Page25

Figure4.2 Calibrationmeasurementsforwaterprobe

4.2.1 Commissioningmeasurementswithroofsuspendedprobes

Ifthecommissioningtakesplacedirectlyafterinstallation,themeasurementsattheprobepositioninfigure4.2havealreadybeenmadeiftheinstructionsarefollowedfromtheinstallationguide.Otherwise,thatmeasurementshouldbemadenow,bypartlyremovingtheprobetoenableameasuringtapetobeloweredfromthenozzle.Thefollowingvaluesareobtained:

• Nozzleheight• Productlevelatwaterprobelocation• Waterlevelatwaterprobelocation

Fromthesemeasurements,calculatethe‘ullage’value‘A’:

A=Nozzleheight-productlevelatwaterprobelocation

Thenextstepistofetchtheproductlevelwithrespecttothetankzeropoint.Thiscanbedoneinseveralways:• Readthelevelfromthelevelgaugeifthathasrecentlybeenchecked(calibrated);• Takeamanual‘innage’measurementtothedatumplateofthetank;• Takeamanual‘ullage’measurementfromtheUpperReferencePointandcalculatethelevelby:level

=URP-‘ullage’.

Refertofigure4.2.Atthebottompartoftheprobethereisaninactivemetalpartwithaheightof25mm(1").Thatisrepresentedasdistance‘B’.Theoffset,whichhastobeprogrammedinitemWB,canbefoundfrom:

WB=(A+productlevelatreferencepoint)-(Nozzleheight-B)Note:

IfWBisanegativefigurethenitispossibletohaveanegativewaterlevelreading.

Calibratingthewaterprobe

RefertoAppendixCforinformationaboutcalibratingthewaterprobe.Whereismentionedthewaterdip,refertothemeasuredwaterlevelattheprobepositionasdescribedbefore.

Page 26: Instruction manual temperature, Water bottom and Analog outp.pdf

Waterbottommeasurement

Page26

Figure4.3 Calibrationmeasurementsforsidemountedprobe

4.2.2 Commissioningmeasurementsforsidemountedprobes

Fromtheprobeinstallationmustbeknown: Activelengthofprobe Totallengthofprobe Angleofinstallation(α) Height‘H’ofnozzle

Thewaterprobelength(WP)canbecalculatedas:

WP=activelengthofprobexcos(α)

Offset(WB)canbecalculatedas:

WB=H-(totallengthxcos(α))

Whenthewaterbottommeasurementhasnorelationtothetankzero,theoffsetWBcanbeusedaswaterprobebottomposition.

Ifthewaterbottommeasurementisrelatedtothetankzero,thenthewaterprobebottomposition(WB)canbedeterminedwhentheprobeisimmersedinsomewater.

Thereadingoftheprobeistaken;itemLW.Amanualwaterdipistakenfromthetankzeropoint(datumplate);notethisvalueas‘W’.CalculatethewaterprobebottompositionWBas:

WB=W-LW

Calibratingthewaterprobe

RefertoAppendixDforinformationaboutcalibratingthewaterprobe.Whereismentionedthewaterdip,refertothemeasuredwaterlevelattheprobepositionasdescribedabove.

Page 27: Instruction manual temperature, Water bottom and Analog outp.pdf

Waterbottommeasurement

InstructionmanualTemperature,WaterbottomandAnalogoutputoptions Page27

4.2.3 Waterprobesettings

Item Name Description

W2= Protectionlevel2 Enterprotectionlevel2

WB= Waterprobebottomposition FormataccordingtoitemLD(default:+000.0000m).Thisitemgivestheoffsettothewaterprobezeropointinrelationwiththetankzeropoint.Refertosections4.2.1and4.2.2howtoobtainthisoffsetvalue.

WP= Waterprobelength FormataccordingtoitemLD(default:+001.0000m).Thewaterprobelength(togetherwiththewaterprobebottomposition)isrequiredtocalculatethewaterlevel.

WF= Waterlevelfieldcommunication Onecharacter:‘S’or‘D’.Onlyvalidwith854levelgauges.Thisitemselectsfromwhichsourcethewaterlevelismeasuredandtransmittedinthelevelrecord(B-record)tothesystem.

S : fromthewaterprobe(VITOwatersensor,WaterScoutorsidemountedwaterprobe)

D : fromwaterdip(displacer)Select‘S’for854thegauges(default:D).

WH= Waterhighalarm FormataccordingtoitemLD(default:+000.0000m).Withthisitemawaterhighalarmsetpointcanbegiven.Whenactive,thewaterhighalarmconditionissignalledontheinstrumentdisplayindisplayformatK(ifdisplayisavailable).Thewateralarminformationisalsotransmittedinthewaterlevelrecord(M-record).

WL= Waterlowalarm FormataccordingtoitemLD(default:+000.0000m).Withthisitemawaterlowalarmsetpointcanbegiven.Whenactive,thewaterlowalarmconditionissignalledontheinstrumentdisplayindisplayformatK(ifdisplayisavailable).Thewateralarminformationisalsotransmittedinthewaterlevelrecord(M-record).

WS= Wateralarmhysteresis FormataccordingtoitemLD(default:+000.0100m).Thewateralarmhysteresispreventsthewateralarmtobeswitchedonandoffwhenthewaterlevelisaroundthewaterhighorwaterlowalarmsetpoint.

EX Exit Exitprotectionlevel.

Waterprobelength:The766VITOwaterandtemperatureprobehasonelengthforthewatermeasurement;theotherwaterprobescanhavedifferentlengths.Theactualwaterprobelengthcanbefoundfromtheidentificationcodeoftheprobe.Thetablebelowgivesanoverview:

765VITO 766VITOwaterand 964WaterScout Sidemountedwaterprobewaterprobe temperatureprobe

0.485m 0.485m 0.5m0.985m Notrequiredto 1.0m1.985m 2.0mspecifyinitemWP

activelengthxcos(α)(refertosection4.2.2)

Page 28: Instruction manual temperature, Water bottom and Analog outp.pdf

Waterbottommeasurement

Page28

4.3 Operation

4.3.1 Display

Foroperationofthedisplayandtheinformationonit,refertotheinstructionmanualoftheapplicablelevelgaugeor877FDI.Below,onlyanoverviewisgivenwhichdisplayformatgivesinformationaboutthewaterbottommeasurement.

Displayformat Displayedinformation

K Waterlevelandstatus

4.3.2 Waterabove/belowprobewarning

Automaticallyawarningisgivenwhenthewaterlevelistoolowortoohighfortheprobetomeasurecorrectly.

• Thewateraboveprobestatus(AP)isdisplayedandsignalledinthewaterlevelrecordwhenthewaterleveliswithin1%oftheprobelength(itemWP)fromthetopofthewaterprobe.

• Thewaterbelowprobestatus(BP)isdisplayedandsignalledinthewaterlevelrecordwhenthewaterleveliswithin1%oftheprobelength(itemWP)fromthebottomofthewaterprobe.

Aroundthesewarningsthereisahysteresisof½%oftheprobelength(itemWP).

4.3.3 Dataitems

Below,asummaryisgivenoftheavailabledataitemsanderrorcodes.Thereisoneoperationalcommandwiththewaterbottommeasurement.

Item Description

LWLHN4PVMX

Measured/ Waterlevel,precededbytwostatusbytes(refertosection4.4.3)calculateddata Waterullage,precededbytwostatusbytes(refertosection4.4.3)

SerialnumberexternalwaterprobeMeasuredcapacitancefromsidemountedwaterprobeMeasuredcapacitancefrom765/766VITOwaterprobe

VV Verificationdata Refertodescriptionatsection4.4.4

EWHEFHH0

Diagnosticdata Errorwaterrequest(refertosection4.4.1)HARTcommunicationerrors(refertosection4.4.2)FatalHCU/ICU_HPIerrorsLastfatalHCU/ICU_HPIerror

Operationalcommand:

SR StopHARTrequest(usedwithHARTcommunicator).

Page 29: Instruction manual temperature, Water bottom and Analog outp.pdf

Waterbottommeasurement

InstructionmanualTemperature,WaterbottomandAnalogoutputoptions Page29

4.4 Troubleshooting

4.4.1 Watererrorrequest(itemEW)

DataitemEWcontainsthemostrecenterrorcodeconcerningthewaterprobemeasurement,encounteredbytheoptionalHCU/ICU_HPIboard.

ItemEWwithexternalwaterbottomprobe(Sidemountedwaterprobeor964WaterScout):xx00 Noerror,valueatinitializationxx11 NoreplyoninitialHARTcommands Checkconnectionlevelgauge-waterprobe;checkifHARTdeviceaddressofwaterprobe

is4;changewaterprobeelectronics,orHCU/ICU_HPIboardxx35 Wrongdimension DimensionofPVshouldbe:m(metres)ormm(millimetres)xx40 Devicemalfunction Defectivewaterprobe(electronics)xx98 Nowatersourcesfound Nowaterprobeconnected

ItemEWwith765and766VITOwaterprobe:xx00 Noerror,valueatinitializationxx01 C error Eitherdefective762VITOInterfaceoradefective(leaking)waterprobetestxx02 Linearityerror Shouldbewithin1%ofthetestcapacitance.Iftoolarge,change762VITOInterfacexx03 Nowaterprobeavailable Measuredcapacitanceis>4000pF;checkwaterprobewiring(greenwireandcoaxcable)to

762VITOInterfaceterminalsxx04 Subsystemerror Defective762VITOInterfacexx05 Capacitancetoolow Measuredcapacitance<50pF;checkwaterprobewiringorchange765/766VITOprobexx06 Capacitancetoohigh Measuredcapacitance>3000pF;checkwaterprobewiringorchange765/766VITOprobexx07 Capacitanceshortcut Eitherwaterprobeerrororinternal762VITOInterfaceerrorxx11 NoreplyoninitialHARTcommands Communicationerror.Checkconnectionlevelgauge-762VITOInterface,orchange762

VITOInterfaceorHCU/ICU_HPIboardxx79 Notcalibrated CheckitemsVRandVT(settozeroorareequaltoeachother)xx98 Nowatersourcesfound Nowaterprobeconnected

xx: 24forHPUemulation; 28forHSUemulation; 30forHCUemulation

4.4.2 HARTcommunicationerrors

ItemHEcontainsfourcounters.Thefirstthreecountersareusedbypressuretransmitters(ifpresent).Thelastcountercontainsthenumberoftimestheexternalwaterprobeisdetectedabsent.Theexternalwaterprobeisconsideredtobeabsentafterthreeconsecutiverequests,orafterreceivingthreeincorrect/invalidanswerrecords. DefaultvalueitemHE 000:000:000:000

4.4.3 Waterlevel(ullage)statusbytes

Thewaterlevelandullage,itemsLWandLH,areconstructedasfollows:s s lllllllll0 1

lllllllll :waterlevel(orullage)value;formataccordingtheleveldimensionLD.s s :twostatusbytes,bitcoded;containingthefollowinginformation:0 1

statusbytes statusbytes0 1

bit 0: generalprobefail bit 0: waterprobe(0=present;1=absent)1: lowwateralarm 1: 0(notused)2: highwateralarm 2: 0(notused)3: waterbelowprobewarning 3: 0(notused)4: wateraboveprobewarning 4: 0(notused)5: 0 5: 06: 1 6: 17: 0 7: 0

Note:Onlythebitswhicharesetto‘1’haveanactivestatus.

Page 30: Instruction manual temperature, Water bottom and Analog outp.pdf

Waterbottommeasurement

Page30

4.4.4 Waterbottompointer(itemsVPandVV)

Bymeansofthevaluepointer(itemVP)avectorcanbeloadedtotheHCUorICU_HPIoptionboard.Next,withitemVV,theselecteddataisreturned.ItemVPconsistsof4positions,inthemiddleseparatedbya‘.’or‘,’:vw.xy(orvw,xy).Thevaluesforthevaluepointerarelistedinthetabletogetherwiththeobtaineddata.

vw , xy Selecteddata Example/Dimension

00 , 00 HCU/ICU_HPIEmulation&Function VV=HCUHCAOMTWTPR

00 , 01 Configurationbootcode VV=HCUCONFIG:3F

00 , 02 HCU/ICU_HPIhardwareversion VV=HWVERSION:0000 , 03 Bootcodesoftwareversion VV=BOOTSWVERS:01

03 , 01 ErrorcountersHARTaddresses3,4,5 VV=0000:0013:0000

03 , 09 DetectedHARTdeviceaddresses (seeVP03,01) VV=1---5---------03 , 10 InitialdetectedVITOdevicetype&s/wversion VV=766PTTCW10

03 , 11 RealactivefunctionsofVITOInterface(refertodescriptionofVP=03,10) VV=766PTTCW03 , 12 ActualexecutedHARTcommandsfrom762VITOInterface

04 , 00 C from762VITOInterface (floatingpointformat) pF04 , 01 C from762VITOInterface (floatingpointformat) pF

Emulation: MPU,HSU,HPU,HCUFunction: HC: HARTchannelinstalled

AO: analogoutputST: spottemperatureMT: VITOaveragetemperatureWS: externalwaterbottomprobeWT: VITOwaterbottomprobePR: pressuretransmitters

Salescodeoption: C bootcode: 0AJ 2EU 25W 1AY 3F

(externalwaterprobehasHARTaddress4and762VITOInterfacehasHARTaddress5)

Description: 765: VITOwaterbottomprobe766: VITOwaterandtemperatureprobewithspotcloseto model:.A..766B<ol><he>

probe’send864: 766VITOwaterandtemperatureprobewith model:.A..766A<ol><he>

referenceresistorandlowestspotat1mPT: Pt100TC: thermocouplesW: waterprobe10: softwareversion1.0

test

linearity

Item Name Description

VP= Waterbottomvaluepointer Waterbottomvaluepointer;format:2digits,separator,2digits (refertotableabove).

Example: VP=04.00:valuepointerloadedtorequestthemeasuredtestcapacitor.

VV Waterbottompointervalue Waterbottompointervalue.ThisitemholdsthevaluerequestedbyitemVP(refertotableabove).Example: therequestedmeasuredtestcapacitor

(standardfloatingpointformat).

Page 31: Instruction manual temperature, Water bottom and Analog outp.pdf

Analogleveloutput

InstructionmanualTemperature,WaterbottomandAnalogoutputoptions Page31

5 Analogleveloutput

5.1 Introduction

TheanalogleveloutputcircuitisanoptionwhichcanbeinstalledontheHCUboard.TheHCUboardisanoptionboardforthe854servogauges,the873SmartRadargaugeanthe877FDI.Forthe973SmartRadarLT,theanalogleveloutputisavailablewiththeoptionalICU_HPOboard.

TheanalogoutputcircuitontheHCUandICU_HPOoptionalboardsaregalvanicallyseparatedfromthegaugeelectronics.

Thissection(analogleveloutput)describesthesettingsforanalogleveloutputforboththeHCUandICU_HPOboard.FortheHART communicationoftheICU_HPOboard,refertoinstructionmanual973SmartRadarLT®

HART communicationoutput.®

5.1.1 HCUanalogoutputcharacteristics

Theanalogoutputispassive,henceanexternalpowersupplyisrequired.Thevoltageoftheloopsupplyshouldbeatleast12Vdc,andmaynotexceed64Vdc(measuredattheterminalsofthegauge).

Theloopresistanceisthetotalresistancefromtheloop,andhenceincludessupplyoutputresistance,totalcableresistance(includingseriesresistor)andtheinputresistancefromreaderoranaloginput.

ToreducethepowerdissipationontheHCUboard,anexternalresistormustbewiredinserieswiththeloopincasetheloopsupplyvoltageishigherthan30Vdc(refertofigure5.1A).Thepowerratingoftheexternalresistancedependsonthevalue;werecommend:1W/kΩ.

5.1.2 ICU_HPOanalogoutputcharacteristics

Theanalogoutputcanbeseteitherpassiveoractive(refertosection5.2.1).Whensettoactive,thesupplyvoltageintheloopis:20Vdc(±5%).

Thevoltageoftheloopsupplyshouldbeatleast8Vdc,andmaynotexceed64Vdc(measuredattheterminalsofthegauge).Supplyvoltagesover30Vdcrequireanexternalseriesresistor(refertofigure5.1B).

Note:HART communicationrequiresaminimumloopresistanceof250Ω.®

ThemaximumloopresistanceforHART communicationis1100Ω.®

ThisimpliesthatforHART communicationtheminimumsupplyvoltageis14Vdcandthemaximumsupply®

voltageis36Vdcwitha250Ωresistor.

Withahigherexternalsupplyvoltage,theseriesresistormustbeincreased.WiththemaximumresistorforHART communication(1100Ω),themaximumloopsupplywillbe57Vdc.®

Thepowerratingoftheexternalresistancedependsonthevalue;werecommend:1W/kΩ.

Page 32: Instruction manual temperature, Water bottom and Analog outp.pdf

Analogleveloutput

Page32

Figure5.1 Supplyvoltageversusloopresistanceforanalogleveloutput

Page 33: Instruction manual temperature, Water bottom and Analog outp.pdf

CN2

CN1

ICU-HPO board

PassiveActive

CN1CN2 -

+

HART

4-20mA

Analogleveloutput

InstructionmanualTemperature,WaterbottomandAnalogoutputoptions Page33

Figure5.2 Changingoverfrompassivetoactiveanalogoutputloopsupply

5.2 Commissioningofanalogleveloutput

5.2.1 Settingofanalogoutput973SmartRadarLTto“active”

SettingtheanalogoutputlooptoactiveorpassiveisdonebyselectingthecorrectconnectorontheICU_HPOboard.Standard,theSmartRadarLT’saredeliveredwiththeanalogoutputloopsetas“passive”.Hence,anexternalsupplyvoltageisrequired.

Whentheanalogloopshouldbesetto“active”,theconnectorontheICU_HPOboardneedstobechangedfromposition.Thatprocedureisdescribedbelow.

1 SwitchoffmainspowerfromtheSmartRadarLT;2 Openelectroniccompartmentcover;3 LocatetheICU_HPOboard(refertofigure5.2);4 LoosenthecableconnectorfromconnectorCN1(passive),andplugitintoCN2(active);5 Closeelectroniccompartmentcover;6 Applymainspower.

ThecommissioningoftheoptionalanalogleveloutputpartoftheHCU/ICU_HPOboardshouldbeperformedafterthebasiccommissioningofthelevelgaugeorindicator.

Page 34: Instruction manual temperature, Water bottom and Analog outp.pdf

Analogleveloutput

Page34

5.2.2 Analogoutputsettings

Item Name Description

W1= Protectionlevel1 Enterprotectionlevel1

AM= Analog4mAlevel FormataccordingtoitemLD(default:+000.0000m).Enterinthisitemthelevelvaluewhichmustcorrespondwiththecurrentof4mA

AN= Analog20mAlevel FormataccordingtoitemLD(default:+000.0000m).Enterinthisitemthelevelvaluewhichmustcorrespondwiththecurrentof20mANote:

ThevalueinitemAMcanbeconsideredas‘offset’;Thevalueof(AN-AM)canbeconsideredas‘span’.

AK= Analogoutputmode Onecharacter,defaultsetto:D(analogoutputdisabled).Viathisitemisselectedunderwhatconditionstheanalogoutputcurrentwilloperate;seetable:

ItemAK Validlevel Invalidlevel LevelfailTime-out/start-up

D Analogoutput disabled

O (overwrite I =3.5mA(duringstart-up)P mode) I =22mA(duringstart-up)

I =<AF>oo

o

Ifno<LV>L I =3.5mA I =3.5mAM I =22mA I =22mA

I =<AL> I =<LV>o oo

o

o

o

A I =3.5mAB I =22mA

I =<AL>oo

o

I I =3.5mAJ I =22mA

I =<AL>oo

o

<AF> : valuegivenbyitemAFinanalogoutputoverwritemode<AL> : actuallevelvalue<LV> : lastvalidlevelvalueI : outputcurrentoNote:

Thesetting‘D’shouldnotbeusedwiththe973SmartRadarLT.

EX Exit Exitprotectionlevel.

Note:Withthe973SmartRadarLTitispossibletowritevalueswiththeHARTcommunicatorforPVLRVandPVURV,whichwillbestoredlocallyontheICU_HPOboardandusedinsteadofresp.itemsAMandAN.

Page 35: Instruction manual temperature, Water bottom and Analog outp.pdf

Analogleveloutput

InstructionmanualTemperature,WaterbottomandAnalogoutputoptions Page35

Figure5.3 Testloopforcalibratinganalogoutputcircuit

5.2.3 Calibrateanalogoutputcircuit

CalibrationoftheanalogoutputcircuitisnecessarywhentheXPUNOVRAMis(re)formattedandtheitemscouldnotbedownloadedfromalogfileorwhenanewHCU/ICU_HPOboardisinstalled.Ofcourse,calibrationcanalsobeperformedasaroutinetobesurehavingagoodsignal.

Connectapowersupply(15-24Vdc)andanaccuratemAmeter(accuracybetterthan10µA)totheinstrument(refertofigure5.3).

Note:The973SmartRadarLTcanbesettoactive.Thennoexternalpowersupplyisrequired.

TheproceduredescribedbelowcanbeusedwiththeHCUboardinthe854servogauges,873SmartRadarand877FDI.

Forthe973SmartRadarLTwiththeICU_HPOboard,thisprocedurecanonlybeusedviatheHART®

communicationusingtheservicetoolEnsiteorEngauge.

Item Name Description

W1= Protectionlevel1 Enterprotectionlevel1

A5 Calibratecommand@4mA Withthiscommandacurrentofapproximately4mAwillflowthroughtheloop.ReadthecurrentindicatedbythemAmeter.

A3= Analogoutput@4mA Floatingpointformat;units:mA.EnterinthisitemthereadingfromthemAmeterundertheconditionofcommandA5(appr.4mA).

A6 Calibratecommand@18mA Withthiscommandacurrentofapproximately18mAwillflowthroughtheloop.ReadthecurrentindicatedbythemAmeter.

A4= Analogoutput@18mA Floatingpointformat;units:mA.EnterinthisitemthereadingfromthemAmeterundertheconditionofcommandA6(appr.18mA).

EX Exit Exitprotectionlevel.

FromICU_HPOsoftwareversionA1.1andhigher,the973SmartRadarLThasanalternativeitemforthecalibrationoftheanalogoutput.

Page 36: Instruction manual temperature, Water bottom and Analog outp.pdf

Analogleveloutput

Page36

Item Name Description

W1= Protectionlevel1 Enterprotectionlevel1

AE=+.40000000E+01 Withthisdataitemacurrentofapproximately4mAwillflowCalibrate@4mA throughtheloop.ReadthecurrentindicatedbythemAmeter.

A3= Analogoutput@4mA Floatingpointformat;units:mA.EnterinthisitemthereadingfromthemAmeterundertheconditionwithitemAEsetto4mA.

AE=+.18000000E+02 Withthisdataitemacurrentofapproximately18mAwillflowCalibrate@18mA throughtheloop.ReadthecurrentindicatedbythemAmeter.

A4= Analogoutput@18mA Floatingpointformat;units:mA.EnterinthisitemthereadingfromthemAmeterundertheconditionwithitemAEsetto18mA.

EX Exit Exitprotectionlevel.

Page 37: Instruction manual temperature, Water bottom and Analog outp.pdf

Analogleveloutput

InstructionmanualTemperature,WaterbottomandAnalogoutputoptions Page37

5.2.4 Verifyoutputcurrent

Theanalogoutputcurrentcanbeverifiedbythesametestset-upasinfigure5.3.TheproceduredescribedbelowcanbeusedwiththeHCUboardinthe854servogauges,873SmartRadarand877FDI.Forthe973SmartRadarLTwiththeICU_HPOboard,thisprocedurecanonlybeusedviatheHART®

communicationusingtheservicetoolEnsiteorEngauge.

Item Name Description

W1= Protectionlevel1 Enterprotectionlevel1

AK= Analogoutputmode Setanalogoutputinoverwritemode:O

EX Exit Exitprotectionlevel.

Item Name Description

AF= Analogoutputoverwrite Floatingpointformat;units:mA.EnterinthisitemacurrentvaluewhichyouwanttoverifyonthemAmeter.Minimumvalue:3.5mA,maximumvalue:22mA.Thecurrentvalue,enteredinitemAF,shouldbeindicatedonthemAmeter.Itmaynotdiffermorethan12µA.

OneormorecurrentvaluescanbeverifiedbymeansofitemAF.Whenready,setitemAKbacktoitsoriginalsetting:

Item Name Description

W1= Protectionlevel1 Enterprotectionlevel1

AK= Analogoutputmode SetitemAKbacktoitsoriginalsetting(refertosection5.2.2).

EX Exit Exitprotectionlevel.

FromICU_HPOsoftwareversionA1.1andhigher,the973SmartRadarLThasanalternativeitemfortheverificationoftheanalogoutput.

Item Name Description

W1= Protectionlevel1 Enterprotectionlevel1

AE= Analogoutputoverwrite Floatingpointformat;units:mA.EnterinthisitemacurrentvaluewhichyouwanttoverifyonthemAmeter.Minimumvalue:3.5mA,maximumvalue:22mA.Thecurrentvalue,enteredinitemAE,shouldbeindicatedonthemAmeter.Itmaynotdiffermorethan12µA.TheoutputcurrentholdsthevaluetillanothervalueisgiveninitemAEortheverificationisendedbymeansofanexitcommand.

EX Exit Exitprotectionlevel.

Page 38: Instruction manual temperature, Water bottom and Analog outp.pdf

Analogleveloutput

Page38

5.3 Operation

5.3.1 Display

Foroperationofthedisplayandtheinformationonit,refertotheinstructionmanualoftheapplicablelevelgaugeor877FDI.Below,onlyanoverviewisgivenwhichdisplayformatgivesinformationabouttheanalogleveloutput.

Displayformat Displayedinformation

J Analogleveloutput

Note:ThereisnodisplayformatJonthe973SmartRadarLT,astheICU_HPOboardisnotconnectedtotheinternalIPCcommunicationbus.

5.3.2 Dataitems

Below,asummaryisgivenoftheavailabledataitemsanderrorcodes.

Item Description

AO

AQ

Measured/ Actualanalogoutputcurrent(floatingpointformat;units:mA)calculateddata ThisvalueisprecededbyonestatuscharacterofitemAQ

(onlywithHCUboardin854/873/877)Actualanalogoutputstatus(refertosection5.4.2)(onlywithHCUboardin854/873/877)

VV Verificationdata Refertodescriptionatsection5.4.3(onlywithHCUboardin854/873/877)

EA

OA

OF

FO

Diagnosticdata Erroranalogoutputrequest(onlywithHCUboardin854/873/877)(refertosection5.4.1)Communicationboard(ICU_HPO)actualstatus(onlyin973)(refertosection5.4.4)Communicationboard(ICU_HPO)lastencounteredfatalerror(onlyin973)(refertosection5.4.5)Communicationboard(ICU_HPO)fatalerrorcounter(onlyin973)

Page 39: Instruction manual temperature, Water bottom and Analog outp.pdf

Analogleveloutput

InstructionmanualTemperature,WaterbottomandAnalogoutputoptions Page39

5.4 Troubleshooting

5.4.1 Analogoutputerrorrequest(itemEA)

ThisitemcontainsthemotsrecentanalogoutputerrorencounteredbytheHCUboard.

xx00 Noerror,valueatinitializationxx15 Notcalibrated ItemsA3and/orA4arenotsetcorrectly(default:+.00000000E+00)xx16 Upper/lowerrangeerror ItemsAMand/orANarenotsetcorrectly(bothequalvalue?)xx20 DACread-backerror Internalerror,trytoresolvewithRScommand(orpoweroff/on).Iferrorpersists,

changeHCUboardxx99 Analogoutputoptionboardnotinstalled ChangeHCUboardforthecorrecttype

xx : 22forMPUemulation30forHCUemulation

5.4.2 Analogoutputstatusrequest(itemAQ)

OnlyvalidwiththeHCUboardinthe854servogauge,873SmartRadaror877FDI.Theactualanalogoutputstatusisonecharacterwhichcanbedividedintotwodatafields:theoutputstatus(4bits:‘os’)andtheoutputvaluestatus(1bit:‘ov’)

AQ: b b b b b b b b7 6 5 4 3 2 1 0

0 1 0 ov os os os os

Outputvaluestatus(b ):40 : within4-20mArange1 : outof4-20mArange

Outputstatus(b ,b ,b ,b ):3 2 1 0

b b b b Analogoutputstatus3 2 1 0SettingofitemAK

Errorcodeondisplay

0 0 0 0 validproductlevelused L,M,A,B,I,J --0 0 0 1 lastvalidproductlevelused L,M LV0 0 1 0 invalidlevelused A,B IL0 0 1 1 novalidproductlevelavailable I,J NL0 1 0 0 nolastvalidlevelavailable L,M NL0 1 0 1 nolevelavailable A,B NL0 1 1 0 leveltime-out L,M,A,B,I,J TO0 1 1 1 invalidlevel I,J IL1 0 0 0 levelfailure A,B,I,J LF1 0 0 1 analogoutputgeneralfail -- FL1 0 1 0 analogoutputdisabled D DA1 0 1 1 overwritevalueused O,P OV1 1 0 0 nooverwritevalueavailable O,P NV1 1 0 1 calibrationmodeentered L,M,A,B,I,J CA

Page 40: Instruction manual temperature, Water bottom and Analog outp.pdf

Analogleveloutput

Page40

5.4.3 Analogoutputpointer(itemsVPandVV)

OnlyvalidwiththeHCUboardinthe854servogauge,873SmartRadaror877FDI.Bymeansofthevaluepointer(itemVP)avectorcanbeloadedtotheHCUoptionboard.Next,withitemVV,theselecteddataisreturned.ItemVPconsistsof4positions,inthemiddleseparatedbya‘.’or‘,’:vw.xy(orvw,xy).Thevaluesforthevaluepointerarelistedinthetabletogetherwiththeobtaineddata.

vw , xy Selecteddata Example/Dimension

00 , 00 HCU/ICU_HPIEmulation&Function VV=HCUHCAOST----

00 , 01 Configurationbootcode VV=HCUCONFIG:3F

00 , 02 HCU/ICU_HPIhardwareversion VV=HWVERSION:0000 , 03 Bootcodesoftwareversion VV=BOOTSWVERS:01

Emulation: MPU,HSU,HPU,HCUFunction: HC: HARTchannelinstalled

AO: analogoutputST: spottemperatureMT: VITOaveragetemperatureWS: externalwaterbottomprobeWT: VITOwaterbottomprobePR: pressuretransmitters

Salescodeoption: V bootcode: 10W 1AX 12Y 3F

Item Name Description

VP= Analogoutputvaluepointer Analogoutputpointer;format:2digits,separator,2digits (refertotableabove).

Example: VP=00.00:valuepointerloadedtorequesttheemulationandfunctions.

VV Analogoutputpointervalue Analogoutputpointervalue.ThisitemholdsthevaluerequestedbyitemVP(refertotableabove).Example: therequestedemulationandfunctions.

5.4.4 Communicationboard(ICU_HPO)actualstatus(itemOA)

OnlyvalidwiththeICU_HPOboardinthe973SmartRadarLT.ItemOAcontainstheactualstatusoftheICU_HPOboard,30secondsafterstartup.Thefirst30secondsafterinitialization(EX,orRScommandorpoweron)thisitemcontainstheICU_HPOsoftwareversion.

OK000 NoerrorencounteredER010 ICU(XPU-part)notfound BadornocommunicationbetweenICUboardandICU_HPOboard.CheckER011 ICU(XPU-part)notresponding connectorbetweenthoseboards,elsechangeeitheroftheboardsER012 ICU(XPU-part)answerwitherrorER020 DACerror Internalerror;trytoresolvewithRScommand(orpoweroff/on).Iferrorpersists,

changeICU_HPOboardER021 notcalibrated ItemsA3and/orA4arenotsetcorrectly(default:+.00000000E+00)ER030 NOVRAMchecksumerror InternalerroronICU_HPOboard.ChangeICU_HPOboardER031 NOVRAMaccesserrorER040 codechecksumerrorER050 RAMerror

Page 41: Instruction manual temperature, Water bottom and Analog outp.pdf

Analogleveloutput

InstructionmanualTemperature,WaterbottomandAnalogoutputoptions Page41

5.4.5 Communicationboard(ICU_HPO)lastencounteredfatalerror(itemOF)

OnlyvalidwiththeICU_HPOboardinthe973SmartRadarLT.ThisitemholdsthelastencounteredfatalerrorcodeoftheICU_HPOboard.

0000 noerrorsencountered0001 cmxerrors Theseerrorsarefatalsoftwareerrorsandshouldnotoccur.0002 programerrors Iftheydooccurandarenotresolvedbyresettingtheinstrument,replacetheICU_HPOboard0003 interrupterrors (inclusiveICU_HPOEPROM).0004 watchdogerrors

Page 42: Instruction manual temperature, Water bottom and Analog outp.pdf

Appendix

Page42

AppendixA ASCIItable

Page 43: Instruction manual temperature, Water bottom and Analog outp.pdf

Appendix

InstructionmanualTemperature,WaterbottomandAnalogoutputoptions Page43

Commandpushbutton

CautionIfthecommandselectionswitch(2)and/orthecommandpushbutton(1)areoperatedaccidentally,

orinthewrongway,thecalibrationdata(PVLRVorPVURV)arelost.

AppendixB Configurationprocedurefor964WaterScout

TheWaterScoutisacapacitivewaterprobe.Thesituationat0%waterlevelmeans:sensitivepartoftheWaterScouttotallyimmersedinproduct.ThemeasuredcapacitanceinthissituationmustcorrespondwiththePVLRVvalue.

Themeasuredcapacitancedepends,amongotherquantities,onthedielectricconstantoftheproduct.TheWaterScouthasbeenpre-calibratedinthefactory,howevernotintheproduct,butinair.Therefore,itisrequiredtodeterminethePVLRVvalueintheactualmeasuredproduct.

ThePVLRVcanbeprogrammedbytwoways:• 1 Bymeansofthecommandselectionswitchandcommandpushbutton• 2 BymeansoftheHART Communicatormodel275®

1 PVLRVsettingwithcommandpushbutton

MakesuretheWaterScoutisproperlyinstalled(refertoinstallationguide964WaterScout).CheckbymeansofahanddipthatnowaterisfoundatthesensitivepartoftheWaterScoutandtheproductlevelissuchthatitcoverstheentiresensitivepart.

Ifthereiswaterfoundwithinthesensitivepart,thenfollowtheprocedurewiththeHART communicator.Ifthis®

isnotpossible,theWaterScouthastobelifteduntilthesensitivepartisnotanymoreimmersedinwater.

Takecarethatthegroundconnectionisstillmaintained;thisisnotonlyrequiredforsafety,butalsorequiredforagoodmeasurement.

ApplypowertotheinstrumenttowhichtheWaterScoutisconnectedandwaitforapproximately2minutes.

1 OpencoverofWaterScouttransmitterbox

2 Setcommandselectionswitch(2)inposition1(mostleftposition)

3 Presscommandpushbutton(1)atleastfor1second

4 Setcommandselectionswitchbackinposition4(mostrightposition)

5 ClosecoverfromWaterScouttransmitterbox.

Page 44: Instruction manual temperature, Water bottom and Analog outp.pdf

% water water level 25 mm offset

sensitive length× 100 %

% water 125 25 0

500× 100 20 %

PV LRV PV URV PV URV PV100 % water

× 100

PV LRV 1000 1000 840100 20

× 100 800 pF

Appendix

Page44

Manualmeasurementofwaterlevel

2 PVLRVsettingwithHART Communicator®

MakesuretheWaterScoutisinstalledproperly(refertoinstallationguide964WaterScout).

Checkbymeansofahanddipthewaterlevel.

Ifthereisnowaterfound,orthewaterlevelisbelowthesensitivepartoftheWaterScout,themeasuredcapacitance(PV)isusedasthevalueforPVLRV.

IfthereiswaterfoundwithinthesensitivepartoftheWaterScout,aninterpolationisappliedonthemeasuredcapacitancetofindthecapacitancevalueatzerowaterlevel.

Refertofigure:manualmeasurementofwaterlevel.

Theinterpolationofthecapacitancevalueisdoneasfollows:

Example:

TocalculatethePVLRVvalue,theactualPV(actualmeasuredcapacitance)andthePVURVcapacitancewith100%waterlevel)shouldbeknown.ThesetwovaluescanbereadbytheHART communicator.®

AnotherwayistorequestforitemPVattheinstrument.ThisitemholdthemeasuredcapacitanceinpF.ThePVURVisalsoprintedonthetestformsuppliedwiththeWaterScout.

ThePVLRVisthencalculatedasfollows:

Example:

Proceedasfollows:

ApplypowertotheinstrumenttowhichtheWaterScoutisconnectedandwaitforapproximately2minutes.

1 Enterprotectionlevel2oftheinstrument.Note:

Ifthe847PETisused,itisadvisedtodisablethekeyboardtime-outfunctionofthePET.

Page 45: Instruction manual temperature, Water bottom and Analog outp.pdf

Appendix

InstructionmanualTemperature,WaterbottomandAnalogoutputoptions Page45

HARTCommunicator1→Offline2 Online3 FrequencyDevice4 Utility

HARTCommunicatorOnline1→4

Generic:Ignorenext50occurrencesofstatus

YES NO

Generic:Analogoutput1anditsdigitalrepresentativeareinfixedmode,andnotresponsivetoinputchanges

NEXT

Generic:Online(Generic)1→Devicesetup2 PV 840.000 pF3 PVAO 4.000mA4 PVLRV 720.000pF5 PVURV1000.000pF

Generic:1→PVLRV2 PVURV

2 Issuethe‘StopHARTrequest’command(itemSR).ThiscommandwillaborttheHARTcommunicationschedular.Note:

ThisisnecessaryastheoptionalHARTboarddoesn’tallowasecondmasterontheHARTline.

3 SwitchontheHARTcommunicator.Waitfortheselftestmessagethatnodeviceisfound.ThenpressOK<F4>.

4 ConnecttheHARTcommunicatortotheHARTcommunicationline(totheWaterScout).

5 TheHARTcommunicatorshowsthefollowingmessageonthedisplay:

Select“Online”bypressingthe“⇓”keyandthe“⇒”key.

6 Afterthescanningiscompleted,thefollowingmessagewillbeshown:Note:

IfmoreHART devicesareconnected,theiraddressesareshowntoo.®

Selecttheprobewithaddress4bypressingthe(“⇓”keyand)“⇒”key.

7 Thefollowingtwomessagesaredisplayedintermittently.AnsweralwayswithNEXT<F3>andYES<F1>.

8 Thefollowingmenuwillbeshown:

Onthismenuthemeasuredcapacitanceisdisplayed(example:PV840pF)aswellasthefactoryprogrammedPVURVvalue(example:PVURV1000pF).Notethesetwovaluesandusetheminthecalculations(ifrequired)asgiveninthebeginningofthissection.

Select4(PVLRV)bypressingthe“⇓”keythreetimesandthe“⇒”key.

9 Select1(PVLRV)fromthenextmenubypressingthe“⇒”key.Enterthe(calculated)valueforPVLRVonthenumericalkeypathandpressENTER<F4>.

10 PressSEND<F2>andpressOK<F4>twice.

11 PressHOME<F3>.ThisconcludesthesettingofthePVLRVvalue.TheHARTcommunicatorcanbeswitchedoffanddisconnected.

12 Giveexitcommand(itemEX)onthe847PET(orbyservicetool),whichthenre-startstheinstrumentandHARTcommunication.

Page 46: Instruction manual temperature, Water bottom and Analog outp.pdf

% water water level 25 mm offset

sensitive length× 100 %

% water 125 25 0

500× 100 20 %

VR VT VT MX

100 % water× 100 VR 1000

1000 840100 20

× 100 800 pF

Appendix

Page46

Manualmeasurementofwaterlevel

AppendixC Configurationprocedurefor765/766VITOwaterprobe

MakesuretheVITOwater(temperature)probeisinstalledproperly(refertoinstallationguideVITO)

Checkbymeansofahanddipthewaterlevel.

Ifthereisnowaterfound,orthewaterlevelisbelowthesensitivepartoftheVITOwaterprobe,themeasuredcapacitanceisusedasthevalueforitemVR.

IfthereiswaterfoundwithinthesensitivepartoftheVITOwaterprobe,aninterpolationisappliedonthemeasuredcapacitancetofindthecapacitancevalueatzerowaterlevel.

Refertofigure:manualmeasurementofwaterlevel.

Theinterpolationofthecapacitancevalueisdoneasfollows:

Example:

TocalculatethevalueforitemVR(minimumcapacitance),theactualmeasuredcapacitance(itemMX)andthemaximumcapacitance(itemVT)shouldbeknown.ThesetwovaluescanbereadbythePETorviatheserviceprogramfromtheinstrument.

Theminimumcapacitancevalueisthencalculatedasfollows:Example:

Proceedasfollows:Applypowertotheinstrumenttowhichthe762VITOInterfaceisconnectedandwaitforapproximately2minutes.

Item Name Description

W2= Protectionlevel2 Enterprotectionlevel2

MX Actualmeasuredcapacitance Readtheactualmeasuredcapacitance(floatingpointformat).

VT Maximumcapacitance Readthemaximumcapacitance(floatingpointformat).

VR= Minimumcapacitance Programtheminimumcapacitance;eitherthevaluefromitemMXorthecalculatedminimumcapacitancevalue(floatingpointformat).

EX Exit Exitprotectionlevel.

Page 47: Instruction manual temperature, Water bottom and Analog outp.pdf

PV URVnew

PV URVorg. PV LRV

cos

PV LRV

PV URVnew 258 12

0.866 12 296 pF

Appendix

InstructionmanualTemperature,WaterbottomandAnalogoutputoptions Page47

Relation: probelength-measuredwaterlevel

AppendixD Configurationofsidemountedwaterprobes

Thesidemountedwaterprobeworksonacapacitiveprinciple.Thesituationat0%waterlevelmeans:sensitivepartofprobetotallyimmersedintheproduct.ThecapacitancemeasuredinthissituationmustcorrespondwiththePVLRVvalue.

Themeasuredcapacitancedepends,amongotherquantities,onthedielectricconstantoftheproduct.Thewaterprobehasbeenpre-calibratedinthefactory,howevernotintheproduct,butinair.Therefore,itisrequiredtodeterminethePVLRVvalueintheactualmeasuredproduct.Checkbymeansofamanualdipthatnowaterispresentinthesensitivepartoftheprobe.Theproductlevelmustbesuchhighthatitcoversthesensitivepartofthewaterprobe.OnlyundertheseconditionsthePVLRVcanbedetermined.

ThePVURVvalueisthemeasuredcapacitancewhenthesensitivepartoftheprobeiscompletelyimmersedinwater.Thisisalsopre-programmedinthefactory.

TheSVvalue(SecondaryVariable)isrequestedinthecommunicationbetweenthewaterprobeandtheinstrument.TheSVisthemeasuredwaterlevelinmetres.

Asthesidemountedwaterprobeisinstalledunderanangleαwiththevertical,theimmersedprobelengthdoesnotcorrespondwiththeactualwaterlevel(refertofigureattheright).Thesolutionforthisistodecreasetheprobelengthvalue(programmedinSVURV)bythefactorcosa.However,thiscan’tbedonebytheHARTcommunicator.

Therefore,anothermethodisused.ThespanofthePV(PVURV-PVLRV)willbeincreasedbythefactorcosα.Usethefollowingmethod:

Note:ItisrequiredtohavethePVLRVvalueadjustedtothecorrectvalue,priortouseitintheformulaabove.

Example:PVLRV: 12pF(correctedfor0%water)PVURV: 258pFangleα: 30°

Proceedasfollows:

Applypowertotheinstrumenttowhichthewaterprobeisconnectedandwaitforapproximately2minutes.

1 Enterprotectionlevel2oftheinstrument.Note:

Ifthe847PETisused,itisadvisedtodisablethekeyboardtime-outfunctionofthePET.

2 Issuethe‘StopHARTrequest’command(itemSR).ThiscommandwillaborttheHARTcommunicationschedular.Note:

ThisisnecessaryastheoptionalHARTboarddoesn’tallowasecondmasterontheHARTline.

Page 48: Instruction manual temperature, Water bottom and Analog outp.pdf

Appendix

Page48

HARTCommunicator1→Offline2 Online3 FrequencyDevice4 Utility

HARTCommunicatorOnline1→4

Generic:Ignorenext50occurrencesofstatus

YES NO

Generic:Analogoutput1anditsdigitalrepresentativeareinfixedmode,andnotresponsivetoinputchanges

NEXT

Generic:Online(Generic)1→Devicesetup2 PV 12.100pF3 PVAO 4.000mA4 PVLRV 15.000pF5 PVURV258.000pF

Generic:1→PVLRV2 PVURV

3 SwitchontheHARTcommunicator.Waitfortheselftestmessagethatnodeviceisfound.ThenpressOK<F4>.

4 ConnecttheHARTcommunicatortotheHARTcommunicationline(tothewaterprobe).

5 TheHARTcommunicatorshowsthefollowingmessageonthedisplay:

Select“Online”bypressingthe“⇓”keyandthe“⇒”key.

6 Afterthescanningiscompleted,thefollowingmessagewillbeshown:Note:

IfmoreHART devicesareconnected,theiraddressesareshowntoo.®

Selecttheprobewithaddress4bypressingthe(“⇓”keyand)“⇒”key.

7 Thefollowingtwomessagesaredisplayedintermittently.AnsweralwayswithNEXT<F3>andYES<F1>.

8 Thefollowingmenuwillbeshown:Onthismenuthemeasuredcapacitanceisdisplayed(example:12.1pF)aswellasthefactoryprogrammedvaluesforPVLRV(example:15pF)andPVURV(example:258pF).ThemeasuredPVhastobeprogrammedinthePVLRV(assumedcondition:sensitivepartofprobenotinwater).WiththeprogrammedPVLRVvalue,thecalculationisdoneforthePVURV

Select4(PVLRV)bypressingthe“⇓”keythreetimesandthe“⇒”key.

9 Select1(PVLRV)fromthenextmenubypressingthe“⇒”key.EnterthevalueforPVLRVonthenumericalkeypathandpressENTER<F4>.

Select2(PVURV)formthemenubypressingthe“⇓”and“⇒”key.Enterthere-calculatedvalueforPVURVonthenumericalpathandpressENTER<F4>.

10 PressSEND<F2>andpressOK<F4>twice.

11 PressHOME<F3>.ThisconcludesthesettingofthePVLRVandPVURVvalues.TheHARTcommunicatorcanbeswitchedoffanddisconnected.

12 Giveexitcommand(itemEX)onthe847PET(orbyservicetool),whichthenre-startstheinstrumentandHARTcommunication.

Page 49: Instruction manual temperature, Water bottom and Analog outp.pdf

Appendix

InstructionmanualTemperature,WaterbottomandAnalogoutputoptions Page49

762VITOInterface

AppendixE Partnumbers

ForVITOfamily:

Refertofigure:762VITOInterface.

Item Description Partno.

1 ProtectivecoveroverHARTterminals 0186.901

2 Printedcircuitboard762VITOInterface 0762.550

3 O-ring,190.18x2.62,NBR70 2132.991

4 Cover762VITOInterface 0186.798

For854ATG/854XTG/873SmartRadar/877FDI:

HCUboardfunctionality Partno.

SpottemperaturePt100 0854.932

Temperatureand/orwaterprobe 0854.930

Temperatureand/orwaterprobe+HARTdevice(s) 0854.931

SpottemperaturePt100+HARTdevice(s) 0854.933

Analogleveloutput 0854.935

Analogleveloutput+VITOtemperatureand/orwaterprobe 0854.936

Analogleveloutput+VITOtemperatureprobe 0854.937

Analogleveloutput+SpottemperaturePt100+VITOtemperatureand/orwaterprobe+HARTdevice(s)

0854.934

For973SmartRadarLT:

ICU_HPIboardfunctionality Partno.

SpottemperaturePt100 0973.922

Temperatureand/orwaterprobe 0973.920

Temperatureand/orwaterprobe+HARTdevice(s) 0973.921

SpottemperaturePt100+HARTdevice(s) 0973.923

SpottemperaturePt100+VITOtemperatureand/orwaterprobe+HARTdevice(s)

0973.924

Page 50: Instruction manual temperature, Water bottom and Analog outp.pdf

Appendix

Page50

AppendixF Relateddocuments

Instructionmanualseries854ATGlevelgaugeInstructionmanualseries854XTGlevelgaugeInstructionmanual873SmartRadarInstructionmanual877FieldDisplay&InterfaceInstructionmanual973SmartRadarLT

InstructionmanualHIMS/HTGandvapourpressure(P3)measurement

Installationguide762VITOInterface&764,765or766VITOtemperatureand/orwaterbottomprobesInstallationguide864MTTMultiThermosensorThermometer

ItemdocumentationforEnraf854,873,877&973gauges

Page 51: Instruction manual temperature, Water bottom and Analog outp.pdf

Index

InstructionmanualTemperature,WaterbottomandAnalogoutputoptions Page51

Index

Activelength . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26Actualmeasuredcapacitance . . . . . . . . 24,28,46Analog20mAlevel . . . . . . . . . . . . . . . . . . . . . . . 34Analog4mAlevel . . . . . . . . . . . . . . . . . . . . . . . . 34Analogoutput H0 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28

@18mA . . . . . . . . . . . . . . . . . . . . . . . . . 35,36@4mA . . . . . . . . . . . . . . . . . . . . . . . . . . 35,36current . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38errorrequest . . . . . . . . . . . . . . . . . . . . . . . . . 39mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34,37overwrite . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37statusrequest . . . . . . . . . . . . . . . . . . . . . 38,39

Angle . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26,47Averagegastemperature . . . . . . . . . . . . . . . . . . 20Averageproducttemperature . . . . . . . . . . . . . . . 20Calibratecommand@18mA . . . . . . . . . . . 35,36Calibratecommand@4mA . . . . . . . . . . . . 35,36Calibration MU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12,20

sidemountedwaterprobe . . . . . . . . . . . . . . . 47waterprobe . . . . . . . . . . . . . . . . . . . . 43,44,46

Caution . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3Communicationboard(ICU_HPO) OA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38,40

actualstatus . . . . . . . . . . . . . . . . . . . . . . 38,40fatalerrorcounter . . . . . . . . . . . . . . . . . . . . . 38lastencounteredfatalerror . . . . . . . . . . . 38,41

Elementconfiguration . . . . . . . . . . . . . . . . . . . . . 10Enabletemperaturetransmission . . . . . . . . . 11,19Error TF . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11,19

analogoutputrequest . . . . . . . . . . . . . . . . . . 38temperaturerequest . . . . . . . . . . . . . . . . 12,20waterrequest . . . . . . . . . . . . . . . . . . . . . . . . 28

FatalHCU/ICU_HPIerrors . . . . . . . . . . 12,20,28Gasimmersiondepth . . . . . . . . . . . . . . . . . . . . . 18HARTcommunicationerrors . . . . . . . . . . . . 28,29HCUboard . . . . . . . . . . . . . 6,7,35,37,39,40,49ICUboard . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33ICU_HPIboard . . . . . . . . . . . . . . . . . . . . . . 6,7,49ICU_HPOboard . . . . . . . . . 6,31,33-35,37,40,41Indicatormode . . . . . . . . . . . . . . . . . . . . . . . . . . 11Items VV(spotelement) . . . . . . . . . . . . . . . . . . 12,14

A3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35,36A4 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35,36A5 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35A6 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35AE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36,37AF . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37AG . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20AK . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34,37AM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34AN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34AO . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38AP . . . . . . . . . . . . . . . . . . . . . . . . . . . 10,12,20AQ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38,39EA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38,39EG . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11,19

Note . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3EM(averagetemperature) . . . . . . . . . . . 20,21

EM(spotelement) . . . . . . . . . . . . . . . . . . 12,13EW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28,29FH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28FM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12,20FO . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38

HE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28,29IM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11LH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28,29LW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28,29M0 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12,20MG . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18MI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10,18MK . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18MN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10MO . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10,18MP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18MQ . . . . . . . . . . . . . . . . . . . . . . . . 12,13,20,21

MW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19MX . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24,46N4 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28

OB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11,19OF . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38,41PV . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28SR . . . . . . . . . . . . . . . . . . . . . . . . . . . 28,45,47TD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10,18

TU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10,18U0-UF . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20V0-VF . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20VP(analogoutput) . . . . . . . . . . . . . . . . . . . . 40VP(averagetemperature) . . . . . . . . . . . . 21,22VP(spotelement) . . . . . . . . . . . . . . . . . . . . . 14VP(waterlevel) . . . . . . . . . . . . . . . . . . . . . . . 30VR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24,46VT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24,46VV(analogoutput) . . . . . . . . . . . . . . . . . 38,40VV(averagetemperature) . . . . . . . . . . . . . 20-22

VV(waterlevel) . . . . . . . . . . . . . . . . . . . . 28,30WB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25-27WF . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27WH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27WL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27WP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26,27WS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27

LastfatalHCU/ICU_HPIerror . . . . . . . 12,20,28Maximumcapacitance . . . . . . . . . . . . . . . . . 24,46Minimumcapacitance . . . . . . . . . . . . . . . . . . 24,46MIR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8MIT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8MRT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8MTT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8,15,16

wiringconnection . . . . . . . . . . . . . . . . . . . . . . 19

Nozzleheight . . . . . . . . . . . . . . . . . . . . . . . . 25,26

Page 52: Instruction manual temperature, Water bottom and Analog outp.pdf

Index

Page52

O-ring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49Optionalboard . . . . . . . . . . . . . . . . . . . . . . . 11,19

HCU . . . . . . . . . . . . . . . . 6,7,35,37,39,40,49ICU_HPI . . . . . . . . . . . . . . . . . . . . . . . . 6,7,49ICU_HPO . . . . . . . . . . . 6,31,33-35,37,40,41

Pointervalue request . . . . . . . . . . . . . . . . . . . . . . . . . . 10,12analogoutput . . . . . . . . . . . . . . . . . . . . . . 38,40temperature(average) . . . . . . . . . . . . . . . . . 22temperature(spot) . . . . . . . . . . . . . . . . . . . . . 14waterbottom . . . . . . . . . . . . . . . . . . . . . . . . . 30

PrimaryVariable . . . . . . . . . . . . . . . . . . . . . . 24,28UpperRangeValue . . . . . . . . . . . . . . . . . . . . 24

PrintVITOInterface . . . . . . . . . . . . . . . . . . . . . . 49Productimmersiondepth . . . . . . . . . . . . . . . . . . 18Productlevel . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25Protectivecover . . . . . . . . . . . . . . . . . . . . . . . . . 49PVLRV . . . . . . . . . . . . . . . . . . . . . . . . . . 24,34,47PVURV . . . . . . . . . . . . . . . . . . . . . . . . . 24,34,47Rearcover . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49RTD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9

position . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10SecondaryVariable . . . . . . . . . . . . . . . . . . . . . . 47Sensitivelengthtemperatureprobe . . . . . . . . . . 18Serialnumberexternalwaterprobe . . . . . . . . . . 28Sidemountedwaterprobe . . . . . . . . . . . . . . 23,27Spotelement . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9Spotpositions . . . . . . . . . . . . . . . . . . . . . . . . . . . 20Spottemperatures . . . . . . . . . . . . . . . . . . . . . . . 20StopHARTrequest . . . . . . . . . . . . . . . . 28,45,47SV . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47SVURV . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47Switchhysteresis . . . . . . . . . . . . . . . . . . . . . 10,18

Waterullage . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28

Temperaturedimension . . . . . . . . . . . . . . . . . . . . . . . . 10,18elementoffset . . . . . . . . . . . . . . . . . . . . . . . . 18errorrequest(averagetemperature) . . . . . . . 21errorrequest(spotelement) . . . . . . . . . . . . . 13

sourceselection . . . . . . . . . . . . . . . . . . . 11,19status . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10statusconversion . . . . . . . . . . . . . . . . . . 10,18statusrequest(averagetemperature) . . . 20,21statusrequest(spotelement) . . . . . . . . . 12,13

Testresistance . . . . . . . . . . . . . . . . . . . . . . . 12,20Totallength . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26Valuepointer

analogoutput . . . . . . . . . . . . . . . . . . . . . . . . . 40temperature(average) . . . . . . . . . . . . . . . . . 22temperature(spot) . . . . . . . . . . . . . . . . . . . . . 14waterbottom . . . . . . . . . . . . . . . . . . . . . . . . . 30

VITO . . . . . . . . . . . . . . . . . . . . 8,15,16,23,27,49Warning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3Wateralarmhysteresis . . . . . . . . . . . . . . . . . . . . 27Watererrorrequest . . . . . . . . . . . . . . . . . . . . . . 29Waterhighalarm . . . . . . . . . . . . . . . . . . . . . . . . 27Waterlevel . . . . . . . . . . . . . . . . . . . . . . . . . . 25,28Waterlevelfieldcommunication . . . . . . . . . . . . . 27Waterlevelstatus . . . . . . . . . . . . . . . . . . . . . . . . 29Waterlowalarm . . . . . . . . . . . . . . . . . . . . . . . . . 27Waterprobe

bottomposition . . . . . . . . . . . . . . . . . . . . . 25-27calibration . . . . . . . . . . . . . . . . . . . . . 43,44,46length . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26,27

Waterprobebottomposition . . . . . . . . . . . . . . . 27

WaterScout . . . . . . . . . . . . . . . . . . . . . . . . . . 23,27