Instruction bookIQAN-XS2Publ. no. HY17-8386-IB/UKEdition September, 2007

®

Page 2: Instruction book IQAN-XS2 - #Numeralkod · The term "manufacturer" refers to Parker Hannifin Corporation. 4 General safety regulations 2 Precautions Instruction book, IQAN- XS2 ...

II

Contents

Instruction book, IQAN-XS2

1 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3Safety symbols . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3

2 Precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4General safety regulations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4

3 Product description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6IQAN-XS2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6

4 Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8

System Diagnostics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9

5 Mounting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10Mounting the module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10

6 Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11Supply voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13

IQAN-XS2 addressing/terminating . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15

Reference voltage, VREF . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16

Voltage inputs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17

Digital outputs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21

7 Start-up . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22Start-up procedures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22

Appendix A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24

IQAN-XS2 Technical Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24Appendix B . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27

Error codes, messages and actions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27Appendix C . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28

Failure Modes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28Appendix D . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30

Dimensioning of the IQAN-XS2 module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30

Page 3: Instruction book IQAN-XS2 - #Numeralkod · The term "manufacturer" refers to Parker Hannifin Corporation. 4 General safety regulations 2 Precautions Instruction book, IQAN- XS2 ...

Safety symbols1 Introduction

1 Introduction

These instructions are to be used as a reference tool for the vehicle manufacturer’s design, production, and service personnel.

The user of these instructions should have basic knowledge in the handling of electronic equipment.

Safety symbolsSections regarding safety, marked with a symbol in the left margin, must be read and understood by everyone using the system, carrying out service work or making changes to hardware and software.

The different safety levels used in this manual are defined below.

WARNING

Sections marked with a warning symbol in the left margin, indicate that a hazardous situation exists. If precautions are not taken, this could result in death, serious injury or major property damage.

CAUTION

Sections marked with a caution symbol in the left margin, indicate that a potentially hazardous situation exists. If precautions are not taken, this could result in minor injury or property damage.

NOTICE

Sections marked with a notice symbol in the left margin, indicate there is important information about the product. Ignoring this could result in damage to the product.

Contact the manufacturer if there is anything you are not sure about or if you have any questions regarding the product and its handling or maintenance.

The term "manufacturer" refers to Parker Hannifin Corporation.

3Instruction book, IQAN- XS2

Page 4: Instruction book IQAN-XS2 - #Numeralkod · The term "manufacturer" refers to Parker Hannifin Corporation. 4 General safety regulations 2 Precautions Instruction book, IQAN- XS2 ...

General safety regulations2 Precautions

2 Precautions

General safety regulationsWork on the hydraulics control electronics may only be carried out by trained personnel who are well-acquainted with the control system, the machine and its safety regulations.

WARNING

Mounting, modification, repair and maintenance must be carried out in accordance with the manufacturer's regulations. The manufacturer has no responsibility for any accidents caused by incorrectly mounted or incorrectly maintained equipment. The manufacturer does not assume any responsibility for the system being incorrectly applied, or the system being programmed in a manner that jeopardizes safety.

WARNING

Damaged product may not be used. If the control system shows error functions or if electronic modules, cabling or connectors are damaged, the system shall not be used.

WARNING

Electronic control systems in an inappropriate installation and in combination with strong electromagnetic interference fields can, in extreme cases, cause an unintentional change of speed of the output function.

NOTICE

As much as possible of the welding work on the chassis should be done before the installation of the system. If welding has to be done afterwards, the electrical connections on the system must be disconnected from other equipment. The negative cable must always be disconnected from the battery before disconnecting the positive cable. The ground wire of the welder shall be positioned as close as possible to the place of the welding. The cables on the welding unit shall never be placed near the electrical wires of the control system.

Construction regulations

CAUTION

The vehicle must be equipped with an emergency stop which disconnects the supply voltage to the control system's electrical units. The emergency stop must be easily accessible to the opera-tor. The machine must be built if possible, so that the supply voltage to the control system's elec-trical units is disconnected when the operator leaves the operator’s station.

Safety during installation

CAUTION

Incorrectly positioned or mounted cabling can be influenced by radio signals which can interfere with the functions of the system.

Safety during start-up

WARNING

The machine's engine must not be started before the control system is mounted and its electrical functions have been verified.

Ensure that no one is in front, behind or nearby the machine when first starting up the machine.

Follow the instructions for function control in the Start-up section.

4Instruction book, IQAN- XS2

Page 5: Instruction book IQAN-XS2 - #Numeralkod · The term "manufacturer" refers to Parker Hannifin Corporation. 4 General safety regulations 2 Precautions Instruction book, IQAN- XS2 ...

General safety regulations2 Precautions

Safety during maintenance and fault diagnosis

CAUTION

Ensure that the following requirements are fulfilled before any work is carried out on the hydraulics control electronics.

• The machine cannot start moving.

• Functions are positioned safely.

• The machine is turned off.

• The hydraulic system is relieved from any pressure.

• Supply voltage to the control electronics is disconnected.

5Instruction book, IQAN- XS2

Page 6: Instruction book IQAN-XS2 - #Numeralkod · The term "manufacturer" refers to Parker Hannifin Corporation. 4 General safety regulations 2 Precautions Instruction book, IQAN- XS2 ...

IQAN-XS23 Product description

3 Product description

IQAN-XS2The IQAN-XS2 is a flexible expansion module designed for controlling hydraulic systems in vehicles and machinery, using 12/24 Vdc power supply.

The IQAN-XS2 module.

I/O overview

InputsThe IQAN-XS2 module has eight (8) voltage inputs VIN-A thru VIN-H for connection of 0-5 Vdc signals. The inputs may be configured as digital inputs DIN-A thru DIN-H. Voltage inputs and digital inputs share positions, see below.

(8) Voltage inputs VIN-A, VIN-B, VIN-C, VIN-D.....VIN-H

or

(8) Digital inputs DIN-A, DIN-B.....DIN-H use positions VIN-A thru VIN-H.

+BAT ADDR-H

ADDR-L

CAN-H

CAN-L

PORT 1

PORT 2

-BAT

+VREF

-VREF

PORT 0

XS2

6Instruction book, IQAN- XS2

Page 7: Instruction book IQAN-XS2 - #Numeralkod · The term "manufacturer" refers to Parker Hannifin Corporation. 4 General safety regulations 2 Precautions Instruction book, IQAN- XS2 ...

IQAN-XS23 Product description

Digital inputs and outputsThe XS2 module has six (6) digital outputs for controlling on/off valves and twelve (12) on/off intputs for switch inputs.

High power On/Off outputsThe XS2 module has six (6) on/off outputs that are high-side power outputs.

CAN related functionsThe master uses the CAN-bus (CAN = Controller Area Network) to communicate with the modules. The CAN-bus is a robust communication protocol that is widely used and well proven within the automotive industry.

(6) on/off outputs, DOUT-G thru DOUT-L (12) on/off inputs, DIN-I thru DIN-T.

(6) On/off outputs, DOUT-A thru DOUT-F

7Instruction book, IQAN- XS2

Page 8: Instruction book IQAN-XS2 - #Numeralkod · The term "manufacturer" refers to Parker Hannifin Corporation. 4 General safety regulations 2 Precautions Instruction book, IQAN- XS2 ...

General4 Safety

4 Safety

GeneralIn order to fulfill the highest safety demands, the XS2 module uses a real-time operating system for fault tolerant embedded systems. The XS2 module has an internal watchdog function. If the RTOS (real time operating system) detects any software errors, necessary precautions will be activated and the watchdog will reset the module.

Polarity reversalThe XS2 module is protected against power supply polarity reversal, provided an external fuse, max 20 A (Fast) is being used.If this fuse is not used, polarity reversal can damage the unit.

CAN-bus interruptionThe XS2 module has special safety functions if the CAN-bus is interrupted. Each module checks for any interruptions in the CAN-bus communication. If an error occurs the master unit will present a related message on the display. The module also indicates the error with an error code ref, section System Diagnostics, on page 9.

Input/ output ProtectionAll inputs on the XS2 module are designed to withstand the maximum specified supply voltage. The outputs are protected against short circuit. Furthermore, an error on one input/output will not influence other inputs/outputs.

Built-in testThe XS2 module will execute a self-test during operation to verify the hardware and the software.

The test includes CAN- bus verification, memory integrity check and an internal signal verification. If any error is detected appropriate precautions will be activated.

8Instruction book, IQAN- XS2

Page 9: Instruction book IQAN-XS2 - #Numeralkod · The term "manufacturer" refers to Parker Hannifin Corporation. 4 General safety regulations 2 Precautions Instruction book, IQAN- XS2 ...

System Diagnostics4 Safety

System DiagnosticsThe yellow blinking LED on the top of the module indicates normal status. If there is an error detected, the master will present a message on the display. The XS2 module also indicates error status through the red blinking LED.This gives an immediate diagnosis as to the nature of the error that has occurred.

The location of the LED indicators on the IQAN-XS2 module.

The green LED indicates power on. The yellow/red LED, will be blinking red when an error has been detected. To get futher information about the error messages, see Appendix B, on page 27

A small recommendation...You can use the internal diagnostics in the master to get more information about the XS2 module. The following values are supervised:

Internal temperature [°C]

Power supply [V]

Reference voltage [V]

CAN address voltage [V]

Green, power on

Yellow/ red, status

9Instruction book, IQAN- XS2

Page 10: Instruction book IQAN-XS2 - #Numeralkod · The term "manufacturer" refers to Parker Hannifin Corporation. 4 General safety regulations 2 Precautions Instruction book, IQAN- XS2 ...

Mounting the module5 Mounting

5 Mounting

Mounting the moduleThe IQAN-XS2 module should be mounted according to the following instructions:

• Locate the module eliminating the risk for the cabling to be folded, crushed or damaged in any way. Ensure the cabling cannot pull, twist or induce sideload on the connector.

• Locate the module so that severe physical impact is avoided, e.g impact from falling objects or the module being used as a step.

• Locate the module so that air can circulat to eliminate excess heat. Ensure that no external heat, e.g. from the engine or heater, is transferred to the module.

• Locate the module to protect it from high pressure washing or similar.

• Locate the module so that the cable connector is facing down .

• Locate the module so that the LEDs are visible.

Non approved placing.

NOTICE

The IQAN-XS2 module must not be placed in any marine related or similar continuously damp environment without external protection.

Assembling of the ID-TagThe ID-Tag will be placed in the connector in order to address/ terminate the module, ref section IQAN-XS2 addressing/terminating, on page 15.The ID-Tag will be mounted under the connector casing. Bend the ID-Tags´ cables toward the opposite side of where the other cables enter the connector.

Assembling of the Id-Tag.

10Instruction book, IQAN- XS2

Page 11: Instruction book IQAN-XS2 - #Numeralkod · The term "manufacturer" refers to Parker Hannifin Corporation. 4 General safety regulations 2 Precautions Instruction book, IQAN- XS2 ...

Mounting the module6 Installation

6 Installation

Connector C1

Connector pin assignments

Connector kit Parker no. 5031063

Housing Amp no. 1-963226-1

Casing Amp no. 0-965643-1

Plane sealing, 42 p installed in module

Pin types* Amp no. 963711-2 (MT) Amp no. 929938-1 (JPT)

Cables 0,75-1,0 mm² (MT) 1,5-2,5 mm² (JPT)

Seals Amp no. 963530-1 (MT) Amp no. 828905-1 (JPT)

Plugs (empty pos.) Amp no. 963531-1 (MT) Amp no. 828922 (JPT)

IQAN crimping tool references

Blue handle, pos. Ause blue extraction tool

Red handle, pos. Buse yellow extraction tool

IQAN tool kit Parker no. 5031061

LogicalSymbol

PinNo.

(I)nput or(O)utput

Function description and/or Signal name(s)

+BAT 28 - Power supply, positive.

-BAT 15 - Power supply, negative ground

+VREF 42 - Voltage reference for external sensors. Sourcing +5V.

-VREF 29 - Voltage reference for external sensors. Return (0V).

ADDR-H 1 - High side to address tag. Sourcing +5V.

ADDR-L 14 - Low side to address tag. Return (0V).

CAN-H 2627

--

CAN high voltage bus line, will be HIGH in dominant state.

CAN-L 4041

--

CAN low voltage bus line, will be LOW in dominant state.

*= The connector contains two types of terminals; MT (Micro Timer) and JPT (Junior Power Timer).

42

28

14

29

15

1

+BAT ADDR-H

ADDR-L

CAN-H

CAN-L

PORT 1

PORT 2

-BAT

+VREF

-VREF

PORT 0

XS2

11Instruction book, IQAN- XS2

Page 12: Instruction book IQAN-XS2 - #Numeralkod · The term "manufacturer" refers to Parker Hannifin Corporation. 4 General safety regulations 2 Precautions Instruction book, IQAN- XS2 ...

Mounting the module6 Installation

Shaded positions are Junior Power Timer pins. Unshaded positions are Micro Timer II pins. See above for wire, seal, pin number and crimping tool information. The IQAN tool kit is found in the ’IQAN accessories’ datasheet.

LogicalSymbol

PinNo.

(I)nput or(O)utput

Function description and/or Signal name(s)

P0

P0.0P0.1P0.2P0.3P0.4P0.5P0.6P0.7

1011121324253839

IIIIIIII

P0 is an 8 pin input port with alternate functions on four inputs.

VIN DIN

VIN-A DIN-AVIN-B DIN-BVIN-C DIN-CVIN-D DIN-DVIN-E DIN-EVIN-F DIN-FVIN-G DIN-GVIN-H DIN-HNote: DIN-A to DIN-H have high impedance inputs (62K Ohm).

P1

P1.0P1.1P1.2P1.3P1.4P1.5

8922233637

OOOOOO

P1 is an 6 pin output port.

DOUT

DOUT-ADOUT-BDOUT-CDOUT-DDOUT-EDOUT-F

P2

P2.0P2.1P2.2

P2.3P2.4P2.5

P2.6P2.7P2.8

P2.9P2.10P2.11

P2.12P2.13P2.14

P2.15P2.16P2.17

21630

31731

41832

51933

62034

72135

OO/IO/I

OO/IO/I

OO/IO/I

OO/IO/I

OO/IO/I

OO/IO/I

P2 is an 18 pin input/output port.

DIN DOUT

- DOUT-GDIN-I -DIN-J -

- DOUT-HDIN-K -DIN-L -

- DOUT-IDIN-M -DIN-N -

- DOUT-JDIN-O -DIN-P -

- DOUT-KDIN-Q -DIN-R -

- DOUT-LDIN-S -DIN-T -

Notes:DIN-I to DIN-T are equipped with clamping diode, risk for “backending”.See section Connecting switches to the digital inputs, on page 20

12Instruction book, IQAN- XS2

Page 13: Instruction book IQAN-XS2 - #Numeralkod · The term "manufacturer" refers to Parker Hannifin Corporation. 4 General safety regulations 2 Precautions Instruction book, IQAN- XS2 ...

Supply voltage6 Installation

Supply voltageBefore any installation of the IQAN system can take place, make sure the ignition lock is turned off and the battery is disconnected.

Emergency stopMake sure an Emergency Stop disconnecting the power supply, is easily accessible at any time. Further relevant regulations are to be found in Machinery Directives 9837/EC. The figure below shows how to connect the emergency stop.

Connecting of Supply VoltageThe supply voltage, should be within the operating interval, see Appendix A, on page 24. Connect the supply voltage to +BAT, position 28 and -BAT, position 15. Protect the module by using a fuse. Requisite fuse level should be 20 A, fast (F).

Connecting the emergency stop and voltage supply.

NOTICE

Do not use the chassis as the negative terminal.

+ -

42

28

14Emergency Stop

29

15

1

+BAT, pos. 28 20 A

-BAT, pos.15

*

* Symbol for disconnecting switch for battery, ignition lock and other fuses.

13Instruction book, IQAN- XS2

Page 14: Instruction book IQAN-XS2 - #Numeralkod · The term "manufacturer" refers to Parker Hannifin Corporation. 4 General safety regulations 2 Precautions Instruction book, IQAN- XS2 ...

Supply voltage6 Installation

Multiple modules connected to voltage supplyWhen connecting several XS2 modules, all of the units will have to be separately connected to the battery voltage and each unit protected with a fuse. Requisite fuse level should be 20 A, fast (F).

EXAMPLE

Connecting several modules to the power supply.

+ -

XS2-A0 XS2-A1 XS2-A2 XS2-A3

- + - + - + - +

+BAT, pos. 28-BAT, pos. 15

-BAT +BAT

20 A

* Symbol for disconnecting switch for battery, ignition lock and other fuses.

*

14Instruction book, IQAN- XS2

Page 15: Instruction book IQAN-XS2 - #Numeralkod · The term "manufacturer" refers to Parker Hannifin Corporation. 4 General safety regulations 2 Precautions Instruction book, IQAN- XS2 ...

IQAN-XS2 addressing/terminating6 Installation

IQAN-XS2 addressing/terminating

AddressingEach XS2 module will have a specific address, enabling the master module to communicate with the modules through the CAN-bus. When operating, the system distinguishes between different modules by first verifying the module type and secondly, through the modules having unique addresses.

The maximum number of similar modules in a system is four or eight depending on the master module, denoted in the first case as addresses 0, 1, 2, 3 respectively. In order to assign any XS2 module a unique CAN-address, an ID-Tag will have to be connected to the positions ADDR-H and ADDR-L.

Connecting of Id-Tag.

TerminatingTo eliminate interference in the communications through the CAN-bus, the CAN-bus must be terminated. Because the master module is always located at the beginning of the bus, the master is provided with an internal termination.You will only need to terminate the end of the bus.

If an IQAN-XS2 is located at the end of the CAN-bus then use an ID-tag having a combined address and terminating function. This is denoted with a "T" for terminating, after the appropriate address such as; 0T, 1T, 2T...

Selecting appropriate Id-Tag• Check the address number of the module.

• If the module is located at the end of the CAN-bus then select the appropriate ID-Tag denoted with a "T".

NOTICE

The CAN-bus must not be terminated at the XS2 using an external regular terminating resistor, due to the fact that terminating is made from within the XS2 module in conjunction with the ID-Tag.

EXAMPLE

If having an XS2 module with address 0, the system will denote this one as XS2-A0, The letter "A" refers to CAN-bus A.

29

15

1

ADDR-H, pos.

42

28

14

ADDR-L, pos.

ID-Tag

15Instruction book, IQAN- XS2

Page 16: Instruction book IQAN-XS2 - #Numeralkod · The term "manufacturer" refers to Parker Hannifin Corporation. 4 General safety regulations 2 Precautions Instruction book, IQAN- XS2 ...

Reference voltage, VREF6 Installation

Reference voltage, VREFThe XS2 module is internally equipped with a voltage regulator to generate the reference voltage VREF. The standard reference voltage will feed different kinds of sensors and potentiometers.

VREF positions.

NOTICE

Maximum load for the VREF is different according to 12/24 Vdc power supply, see Appendix A, on page 24.

-VREF, pos 29

+VREF, pos 42

16Instruction book, IQAN- XS2

Page 17: Instruction book IQAN-XS2 - #Numeralkod · The term "manufacturer" refers to Parker Hannifin Corporation. 4 General safety regulations 2 Precautions Instruction book, IQAN- XS2 ...

Voltage inputs6 Installation

Voltage inputs

Connecting sensors to the voltage inputsThe sensor signal range must be 0-5 Vdc. To detect signal errors such as short circuits or interruptions the active signal range be within 0.5-4.5 Vdc.

Active signal range.

The current consumption related to the voltage input is negligible.

The positive terminal of the sensor is connected to the +VREF position and the corresponding negative terminal to the -VREF position. The sensor signal is connected to appropriate VIN position.

NOTICE

The negative terminal of the sensor must not be connected to the chassis.Maximum load for VREF position: see Appendix A, on page 24.

EXAMPLE

Connect the positive and negative terminals of the position sensor to +VREF, position 42, and -VREF, position 29, respectively. Then connect the sensor signal to VIN-A, position 10.

Connecting VREF and sensor signal VIN-A.

0

5[V]

Active signal range

Error detection range

Error detection range

t

-VREF, pos. 29

+VREF, pos. 42

VIN-A, pos. 10

Position Sensor

42

28

14

29

15

1

17Instruction book, IQAN- XS2

Page 18: Instruction book IQAN-XS2 - #Numeralkod · The term "manufacturer" refers to Parker Hannifin Corporation. 4 General safety regulations 2 Precautions Instruction book, IQAN- XS2 ...

Voltage inputs6 Installation

Connecting a temperature sensor to voltage inWhen you connect a temperature sensor you may need to use a pull up resistor on the input signal. Please check the technical data for your specific temperature sensor.

EXAMPLE

Connect the negative terminal of the temperature sensor to -VREF, position 29, and the signal to VIN-A, position 10. The pull up resistor will be connected between VIN-A, position 10 and +VREF, position 42.

Connecting -VREF and temperature sensor signal VIN-A.

The pull up resistor is 4,7 KΩ.

VIN

VREF-

VREF+

Pull up

Pull up

4,7k

-VREF pos 29VIN-A pos 10

+VREF pos 42

29

15

1

42

28

14

18Instruction book, IQAN- XS2

Page 19: Instruction book IQAN-XS2 - #Numeralkod · The term "manufacturer" refers to Parker Hannifin Corporation. 4 General safety regulations 2 Precautions Instruction book, IQAN- XS2 ...

Voltage inputs6 Installation

Connecting switches to the voltage inputsSwitches could be connected to the voltage inputs, to create a digital on/off signal. The switches should be connected to +VREF and VIN/DIN respectively for 5V signal. The current consumption for the input is negligible.

NOTICE

Maximum load for VREF position, see Appendix A, on page 24.

It is recommended to connect system voltage +BAT to the input through a switch in order to reserve 5Vdc VREF for sensors and potentiometers.

DIN-A to DIN-HThese 8 digital inputs share pins with VIN-A to VIN-H and have high impedance characteristics. The above examples apply to these inputs.

DIN-I to DIN-TThese 12 digital inputs have low impedance characteristics and an internal power clamping diode. Therefore, they must be connected in a way that prevents "backending". See the following section for more information.

EXAMPLE

Connect the positive and negative terminals of the switch to +VREF, position 42, and VIN-A/DIN-A, position 10, respectively.

Connecting a switch to VIN-A/DIN-A and VREF.

EXAMPLE

Connect the positive and negative terminals of the switch to supply or the unit’s +BAT, position 28 and VIN-A/DIN-A, position 10, respectively.

Connecting a switch to VIN-A/DIN-A and +BAT.

VIN-A/DIN-A, pos. 10

+VREF, pos. 42

29

15

1

42

28

14

+BAT, pos. 28

29

15

1

42

28

14

VIN-A/DIN-A, pos. 10

19Instruction book, IQAN- XS2

Page 20: Instruction book IQAN-XS2 - #Numeralkod · The term "manufacturer" refers to Parker Hannifin Corporation. 4 General safety regulations 2 Precautions Instruction book, IQAN- XS2 ...

Voltage inputs6 Installation

Connecting switches to the digital inputsWhen connecting switches to the digital inputs DIN-I thru DIN-T, extra precautions should be taken.

There is a possibility of ’backending’ the XS2 unit when using these digital inputs. The internal circuitry has power clamping diodes between the input pins and +BAT. This arrangement creates a risk of inadvertently supplying power to the unit by forward biasing the clamping diodes.

There are two methods to avoid this:

1 The switch could be powered by the same source as the unit’s +BAT. This needs to be after any switch that would shut off power to the XS2.

2 The switch could be connected to DIN through a 1K ohm resistor to limitthe current source capability.

EXAMPLE

Connect the positive and negative terminals of the switch to +BAT, position 28 and DIN-I, position 16, respectively.

Connecting a switch to DIN-I and +BAT.

EXAMPLE

Connect the positive and negative terminals of the switch to supply and DIN-I through a 1K resistor, to position 16, respectively.

Connecting a switch to DIN-I and supply thru a resistor.

+BAT, pos. 28

29

15

1

42

28

14

DIN-I, pos. 16

+ -

Supply

29

15

1

42

28

14

DIN-I, pos. 16 1K ohm

20Instruction book, IQAN- XS2

Page 21: Instruction book IQAN-XS2 - #Numeralkod · The term "manufacturer" refers to Parker Hannifin Corporation. 4 General safety regulations 2 Precautions Instruction book, IQAN- XS2 ...

Digital outputs6 Installation

Digital outputs The digital outputs control relays and on/off valves. For the maximum load per output see Appendix A, on page 24.

Connecting loads to digital outputsConnecting of loads to the digital outputs such as on/off valves is done by using the DOUT-A thru DOUT-L positions and chassis as ground.

Protection against voltage transientsA clamping diode must be placed between the digital output and ground, as close to the load as possible. This protects the output against high voltage transients.Use the diode: 1N5408 (3A/1000V).Depending on the load, other clamping diodes might be used instead.

EXAMPLE

Connect the on/off valve to the digital output using the DOUT-A, position 8, and the chassis as ground.A clamping diode must be placed as close to the load as possible, see figure below.

Connecting a load to the digital output.

If the load is controlled in parallel with another system, the digital output shall be protected with a diode.

Digital output protected with a diode.

29

15

1

d1

DOUT-A

DOUT-A, pos.21

42

28

14

DOUT-A, pos.21

+BATd2

d1

29

15

1

42

28

14

21Instruction book, IQAN- XS2

Page 22: Instruction book IQAN-XS2 - #Numeralkod · The term "manufacturer" refers to Parker Hannifin Corporation. 4 General safety regulations 2 Precautions Instruction book, IQAN- XS2 ...

Start-up procedures7 Start-up

7 Start-up

Start-up proceduresThis chapter contains instructions for action to be taken in connection with the initial start, for example, setting values, calibrating and testing the system.

WARNING

Risk of injury!If the control system is not fitted properly, the machine could move uncontrollably. The machine’s engine shall not be started before the control system is completely fitted and its signals are verified.

Starting the control system

Start the control system as follows:• Prior to start, all modules and cables are to be fitted correctly.

• Check fuses, i.e. make sure that the supply voltage to the modules is equipped with the cor-rect fuse.

• Make sure that connections for supply voltage and return lines are correct in the cable’s con-ductor joint.

• Make sure that the ID-tag is connected properly.

• Make sure the emergency stop works.

The emergency stop should disconnect the supply voltage to all modules.

Emergency stop.

Alternatively, the emergency stop may also shut off the diesel engine or a dump valve, and with that depressurize the hydraulic system.

+BATDump valve

22Instruction book, IQAN- XS2

Page 23: Instruction book IQAN-XS2 - #Numeralkod · The term "manufacturer" refers to Parker Hannifin Corporation. 4 General safety regulations 2 Precautions Instruction book, IQAN- XS2 ...

Start-up procedures7 Start-up

Prepare for system start

WARNING

Make sure no one is in dangerous proximity to the vehicle to avoidinjuries when it starts.

Prepare for the initial system start as follows:• The engine for the hydraulic system’s pump shall be in off position.

• Make sure that all connectors are properly connected.

• Turn on the control system.

• Make sure that voltage is being supplied to all modules, the green diode shall be illuminated on all modules. Also make sure that master is in contact with all modules by reading the master’s display. Error messages are displayed if the master is not in contact with one or more of the modules.

• Make sure the emergency stop is functioning properly.

Start the system

Start the system as follows:• Start the engine for the hydraulic system’s pump, assuming that the above mentioned inspec-

tions have been carried out and shown correct values.

• Calibrate and adjust input and output signals according to the instructions related to the mas-ter menu system and check each and every output function carefully.

• In addition to these measures, the machine shall also meet the machine directives for the country in question.

23Instruction book, IQAN- XS2

Page 24: Instruction book IQAN-XS2 - #Numeralkod · The term "manufacturer" refers to Parker Hannifin Corporation. 4 General safety regulations 2 Precautions Instruction book, IQAN- XS2 ...

IQAN-XS2 Technical OverviewAppendix A

Appendix A

IQAN-XS2 Technical Overview

Absolute Maximum Ratingsa

a.The “Absolute Maximum Ratings” table lists the maximum limits to which the device can be sub-jected without damage. This doesn´t imply that the device will function at these extreme con-ditions, only that, when these conditions are removed and the device operated within the“Recommended Operating Conditions”, it will still be functional and its useful life won’t have beenshortened.

ParameterLimit values

Unit Remarkmin. typ. max.

Ambient temperature, TAStorage temperature

– 40– 40

+90+100

°C

Maximum voltage supply on +BAT 34 V Reverse polarity protected with 20A fuse.

Voltage on any pin withrespect to -BAT

34 V

Maximum current into -VREF 2 A

Maximum current sourced by all outputs 20 A

Environmental ratings

Parameter Remark

EMIISO 14982:1998, Radiated emissionEN 55025:2003, Conducted emissionISO 11452-2:1995, Radiated SusceptilbilityISO 11452-4:2001, Conducted SusceptibilityISO 7637-2:2004, Conducted transient susceptibility on powerISO 7637-3:1995, Conducted transient susceptibility on signalEN 61000-4-8:1993

30-1000 MHz0.15-108 MHz, class 120-1000 MHz, 100V/m1-200 MHz, 150mA1,2a,2b,3a,3b,4, 580V100A/m

ESDISO 10605:2001, ESD 15KV, air,

8 KV contact4 KV handling

Mechanical environmentIEC 60068-2-64:1993 Fh, Random vibrationIEC 60068-2-29:1987 Eb, Bump

0.4 g²/Hz, 15- 250 Hz, 10 hours40g, 6 ms,1000 in each direction

Climate environmentIEC 60529:2001, Enclosure protectionDIN 40050 Part 9:1993, Enclosure protectionIEC 60068-2-30:1985 Db, Damp heat cyclicIEC 60068-2-78:2001, Damp heat, steady stateIEC 60068-2-14:1984 Nb, Change of temperature

IP66: 100 l/min, 3minIP6K9K: 1000kPa, +80°C, 30sec55°C, 6 cycles40°C, 93% RH, 21 days-40°C to 70°C, 100 cycles

Chemical environmentIEC 60068-2-52:1996 Kb, Salt mist 3 days

24Instruction book, IQAN-XS2

Page 25: Instruction book IQAN-XS2 - #Numeralkod · The term "manufacturer" refers to Parker Hannifin Corporation. 4 General safety regulations 2 Precautions Instruction book, IQAN- XS2 ...

IQAN-XS2 Technical OverviewAppendix A

Recommended Operating Conditionsa

ParameterLimit values

Unit Remarkmin. typ. max.

Ambient temperature, TA – 40 +70 °C

Voltage supply, VBAT 11 32 V

Total load on DOUT 20 A

a.Recommended operating conditions are given for maximum and minimum conditions where nor-mal performance is still available from the device. Once the normal operating conditions are exceed-ed, the performance of the device may suffer.

SystemTA = +25 °C (unless otherwise specified)

ParameterLimit values

Unit Remarkmin. typ. max.

Start-up delay 250 ms Power to activated output

Sample rate local I/O 1000 Hz

CAN message response time 1 ms

Output voltage on VREF 4.9 5.0 5.1 V load < 40mA

Maximum load current on VREFVBAT =11V to 32V

40100150

mA Vdrop < 25mV (0.5%)Vdrop < 50mV (1%)Vdrop < 100mV (2%)

Current supplyVBAT =14VVBAT =28V

9575

mAoutputs = offno load on VREF

25Instruction book, IQAN-XS2

Page 26: Instruction book IQAN-XS2 - #Numeralkod · The term "manufacturer" refers to Parker Hannifin Corporation. 4 General safety regulations 2 Precautions Instruction book, IQAN- XS2 ...

IQAN-XS2 Technical OverviewAppendix A

I/OTA = +25 °C (unless otherwise specified)

ParameterLimit values

Unit Remarkmin. typ. max.

VIN (Voltage input)

Signal range low 0 0.05 V

Signal range high 4.9 5.0 5.1 V

Input resistance 62 kΩ

Signal resolution 5 mV

Total unadjusted error -35-100

35100

mV VREF as source <40mAExternal source

DIN (On/off input)

Input low 1.0 V

Input high 4.0 V

Trigg level, high level (1) 3.01.63.01.6

V DIN-A to DIN-HDIN-I to DIN-NDIN-O to DIN-RDIN-S to DIN-T

Trigg level, low level (0) 2.51.22.51.2

V DIN-A to DIN-HDIN-I to DIN-NDIN-O to DIN-RDIN-S to DIN-T

Input resistance 5.662

kΩ DIN-A to DIN-LDIN-M to DIN-T

DOUT (on/off output)

Load current 2 A

Voltage drop (VBAT -VDOUT)

load IL = 0.5Aload IL = 2A

0.20.8

V

Off-State output current: 101.8

uAmA

DOUT-A to DOUT-FDOUT-G to DOUT-L

Max load inductance: 2001000

mH @ 2A@ 1A

Short Circuit current limit 6 A

26Instruction book, IQAN-XS2

Page 27: Instruction book IQAN-XS2 - #Numeralkod · The term "manufacturer" refers to Parker Hannifin Corporation. 4 General safety regulations 2 Precautions Instruction book, IQAN- XS2 ...

27

Error codes, messages and actionsAppendix B

Instruction book, IQAN-XS2

Appendix B

Error codes, messages and actionsIf one of the following error is detected, a message will be presented on the display together with an error code on the module. In some cases, the module will turn off or at least shut down the outputs, to increase safety.

The location of the LED indicators on the IQAN-XS2 module.

WARNING

Don’t use the machine if an error message or error code is activated.

The following sections will present what measures to take for different error situations put into appropriate context.

LED indicator showing different XS2 modes

Status Flash

Normal operation (yel.)

Error code

Error Primary Flash (red)Error category

Secondary Flash (yellow)Error description

1:n See note a

a. Error groups 1:n and 2:n are controlled by the master.

2:n See note a

3:1 CAN error

3:2 Address error

4:1 Memory errorb

b. FRAM memory error.

FE Fatal error

Green, power on

Yellow/ red, status LED

Page 28: Instruction book IQAN-XS2 - #Numeralkod · The term "manufacturer" refers to Parker Hannifin Corporation. 4 General safety regulations 2 Precautions Instruction book, IQAN- XS2 ...

Failure ModesAppendix C

Appendix C

Failure ModesThe following tables contain information about the different possible failures that could occur for each module subsystem. In most cases when an error is detected, a message will be presented on the master display together with an error code on the module. In some cases, the module will turn off or at least shut down the outputs, to increase safety.

Failure modes for VREF

Failure modes for CAN interface

Failure mode Effect

1 +VREF Open VIN out of range, will create a VIN error =>

VIN=Predefined error value.a

a. Measure is controlled by CAN master and application as a result from the CAN error message. Turning outputs off is controlled by CAN master unit and therefore delayed maximum 2 bus cycles.

2 -VREF Open VIN out of range, will create a VIN error =>

VIN=Predefined error value.a

3 +VREF Short-circuit to -VREF VREF error => VIN out of range, will create a VIN

error => VIN=Predefined error value.a

4 +VREF Short-circuited to +BAT VREF error => VIN out of range, will create a VIN

error => VIN=Predefined error value.a

5 +VREF Short-circuited to -BAT VREF error => VIN out of range, will create a VIN

error => VIN=Predefined error value.a

6 -VREF Short-circuited to +BAT External fuse (if <7.5A) on +BAT blows.

7 -VREF Short-circuited to -BAT Not detected.

Failure mode Effect

1 CAN-H to -BAT No CAN communication. All output turned off.

2 CAN-L to -BAT No CAN communication. All output turned off.

3 CAN-H to +BAT No CAN communication. All output turned off.

4 CAN-L to +BAT No CAN communication. All output turned off.

5 CAN-L open circuit No CAN communication. All output turned off.

6 CAN-H open circuit No CAN communication. All output turned off.

7 CAN-L to CAN-H No CAN communication. All output turned off.

8 CAN-termination failure, termina-tion on

No effect

9 CAN-termination failure, termina-tion off

Dependent on CAN size and number of CAN nodes.

28Instruction book, IQAN-XS2

Page 29: Instruction book IQAN-XS2 - #Numeralkod · The term "manufacturer" refers to Parker Hannifin Corporation. 4 General safety regulations 2 Precautions Instruction book, IQAN- XS2 ...

Failure ModesAppendix C

Failure modes for VIN

Failure modes for DIN

Failure mode Effect

1 VIN Open VIN out of range, will create a VIN error =>

VIN=Predefined error valuea

a. Measure is controlled by CAN master and application as a result from the CAN error message. Turning outputs off is controlled by CAN master unit and therefore delayed maximum 2 bus cycles.

2 VIN Short-circuited to +BAT VIN out of range, will create a VIN error =>

VIN=Predefined error valuea

3 VIN Short-circuited to -BAT VIN out of range, will create a VIN error =>

VIN=Predefined error valuea

Failure mode Effect

1 DIN Open No effect on module, not detected

2 DIN Short-circuited to +BAT No effect on module, not detected

3 DIN Short-circuited to -BAT No effect on module, not detected

29Instruction book, IQAN-XS2

Page 30: Instruction book IQAN-XS2 - #Numeralkod · The term "manufacturer" refers to Parker Hannifin Corporation. 4 General safety regulations 2 Precautions Instruction book, IQAN- XS2 ...

30

Dimensioning of the IQAN-XS2 moduleAppendix D

Instruction book, IQAN-XS2

Appendix D

Dimensioning of the IQAN-XS2 module

7 m

m/M

6(x2

)

142

164

60

32

67

52

75U

nit

= m

m