Top Banner
INSTALLATION AND OPERATION INSTRUCTIONS LD56000 01/2012 Jacuzzi ® Luxury Bath 14525 Monte Vista Avenue™ Chino, CA 91710 1-800-288-4002 www.jacuzzi.com COMFORT™ COLLECTION
18

Installation Manual Template - Lowe'spdf.lowes.com/installationguides/731352684654_install.pdfINSTALLATION AND OPERATION INSTRUCTIONS ... wire connector is provided on the exterior

Apr 12, 2020

Download

Documents

dariahiddleston
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: Installation Manual Template - Lowe'spdf.lowes.com/installationguides/731352684654_install.pdfINSTALLATION AND OPERATION INSTRUCTIONS ... wire connector is provided on the exterior

INSTALLATION AND OPERATION INSTRUCTIONS

LD56000 01/2012

Jacuzzi® Luxury Bath14525MonteVistaAvenue™

Chino,CA917101-800-288-4002www.jacuzzi.com

COMFORT™ COLLECTION

Page 2: Installation Manual Template - Lowe'spdf.lowes.com/installationguides/731352684654_install.pdfINSTALLATION AND OPERATION INSTRUCTIONS ... wire connector is provided on the exterior

Page2 www.jacuzzi.com InstallationandOperation

Comfort™CollectionEn

glis

hComfort™Collection

Product Information

Contents

Savetheseinstructionsforfutureuse.Usetheformbelowtorecordyourmodelandserialnumberforfuturereference.

DatePurchased

PurchasedFrom

InstalledBy

SerialNumber

Model

Installer:Leavethemanualforthehomeowner.

Homeowner:Readthismanualandkeepforfuturereference.

NOTE

Contents.......................................................................................................................................................................... 2ProductInformation......................................................................................................................................................... 2ImportantSafetyInstructions........................................................................................................................................... 3InspectionandTesting..................................................................................................................................................... 4VisualInspection............................................................................................................................................................. 4BathtubWaterandOperationalTest................................................................................................................................ 4FramingandSupport....................................................................................................................................................... 5ElectricalConnections..................................................................................................................................................... 6InstallationProcedures................................................................................................................................................... 7UndermountInstallation.................................................................................................................................................. 8Cleanup........................................................................................................................................................................... 9GeneralOperationInformation........................................................................................................................................ 9WhirlpoolOperation......................................................................................................................................................... 9WhirlpoolOperationw/Chromatherapy.......................................................................................................................... 10PurgingtheWhirlpoolSystem........................................................................................................................................11PurgingtheAirBathSystem..........................................................................................................................................11AirBathSystem............................................................................................................................................................. 10In-LineMaintenanceHeater(Whirlpoolmodelsonly).....................................................................................................11Cleaning.........................................................................................................................................................................11Maintenance.................................................................................................................................................................. 12SkirtPanelInstallation(Skirtedmodelsonly)................................................................................................................ 12TroubleshootingProcedures......................................................................................................................................... 13AuthorizedService........................................................................................................................................................ 14Warranty........................................................................................................................................................................ 15

Page 3: Installation Manual Template - Lowe'spdf.lowes.com/installationguides/731352684654_install.pdfINSTALLATION AND OPERATION INSTRUCTIONS ... wire connector is provided on the exterior

Comfort™Collection

InstallationandOperation www.jacuzzi.com Page3

Comfort™Collection Comfort™Collection

Engl

ish

Important Safety Instructions

READ AND FOLLOW ALL INSTRUCTIONS. SAVE THESE INSTRUCTIONS. Usethisunitonlyforitsintendeduseasdescribedinthismanual.Donotuseattachmentsnotrecommendedbythemanufacturer.Neverdroporinsertanyobjectintoanyopening.

Thisisaprofessionalgradeproduct.Aworkingknowledgeofconstructiontechniques,plumbingandelectricalinstallationaccordingtocodesarerequiredforproperinstallationandusersatisfaction.WerecommendthatalicensedcontractorperformtheinstallationofallJacuzzi®LuxuryBathproducts.Ourwarrantydoesnotcoverimproperinstallationrelatedproblems.

DANGER RISKOFACCIDENTALINJURYORDROWNING!Donotpermitchildrento usethisunitunlesstheyarecloselysupervisedatalltimes.Donotusehydromassagebathtubs unlessallsuctionguardsareinstalledtopreventbodyandhairentrapment.Neveroperatethe hydromassagebathifthesuctioncoverisbroken,damagedormissing.Donotoperatethisunit withouttheguardovertheintakeforthecirculationpump(suctioncover/strainer).

DANGER RISKOFSEVEREINJURYFROMELECTRICSHOCKORDEATH FROMELECTROCUTION!Thisunitmustbeconnectedonlytoasupplycircuitthat isprotectedbya15ampgroundfaultcircuitinterrupter(GFCI).SuchaGFCIshouldbeprovided bytheinstallerandshouldbetestedonaroutinebasis.Followthemanufacturer’sinstructions whentestingtheGFCI.TheGFCIshouldinterruptpower.Pushtheresetbutton.Powershould be restored. If the GFCI fails to operate in this manner, the GFCI is defective. If the GFCI interruptspowertothebathtubwithoutthetestbuttonbeingpushed,agroundcurrentisflowing, indicatingapossibilityofanelectricshock.Donotusethishydromassagebathtub.Disconnect thehydromassagebathtubandhavetheproblemcorrectedbyaqualifiedservicerepresentative beforeusing.

DANGER RISKOFELECTRICSHOCK!Donotpermitelectricalappliances(suchasahair dryer,lamp,telephone,radioortelevision)within60”(1524mm)ofthishydromassagebathtub. Connectonlytoacircuitprotectedbyagroundfaultcircuitinterrupter(GFCI).(Forpermanently connectedunits)Agreencoloredterminal(orawireconnector)marked“G,”“GR,”“GROUND,” orGROUNDING”)isprovidedwithintheterminalcompartment.Toreducetheriskofelectric shock,connecttheterminalorconnectortothegroundingterminalofyourelectricserviceor supplypanelwithaconductorequivalentinsizetothecircuitconductorssupplyingthe equipment.

DANGER PROLONGEDIMMERSIONINHOTWATERMAYINDUCE HYPERTHERMIA!Hyperthermiaoccurswhentheinternaltemperatureofthebody reachesalevelseveraldegreesabovethenormalbodytemperatureof98.6°F(37°C).The symptomsofhyperthermiaincludeanincreaseintheinternaltemperatureofthebody,dizziness, lethargy,drowsinessandfainting.Theeffectsofhyperthermiainclude: A. Failuretoperceiveheat. B. Failuretorecognizetheneedtoexitthebath. C. Unawarenessofimpendinghazard. D. Fetaldamageinpregnantwomen. E. Physicalinabilitytoexitthebath. F. Unconsciousnessresultingindangerofdrowning.

DANGER Thisequipmentisintendedforindooruseonly.Installtheequipmentinaccordancewiththese instructions.Usesupplywiresthataresuitablefor167°F(75°C),includingthetemperature ratingofthesupplyconductorstobeused.Thisunitshouldbeelectricallygroundedandinstalled byalicensedcontractor,electrician,andplumber.Buildingmaterialsandwiringshouldberouted awayfromthemotor/pumporblowerorotherheatproducingcomponentsofthisunit.Apressure wireconnectorisprovidedontheexteriorofthemotor/pumpandheatertopermitconnectionof anNo.8AWGsolidcopperbondingconductorbetweenthisunitandallotherelectricequipment andexposedmetalinthevicinity,asneededtocomplywithlocalrequirements.

DANGER Riskoffetalinjury.Pregnantorpossiblypregnantwomenshouldconsultaphysicianbefore usingahydromassagebathtubequippedwithaheater

Page 4: Installation Manual Template - Lowe'spdf.lowes.com/installationguides/731352684654_install.pdfINSTALLATION AND OPERATION INSTRUCTIONS ... wire connector is provided on the exterior

Page4 www.jacuzzi.com InstallationandOperation

Comfort™CollectionEn

glis

hComfort™Collection

Bathtub Water and Operational Test

Inspection and TestingVisual Inspection

Important Safety Instructions (Cont)

Allbathtubunitsarefactorytestedforproperoperationandwatertightconnectionspriortoshipping.However,theunitmustberetestedbytheinstallerpriortoinstallation.JacuzziLuxuryBathisnotresponsibleforanydefectthatcouldhavebeendiscovered,repaired,oravoidedbyfollowingthisinspectionandtestingprocedure:

1 Placethebathtubonalevelsurface,nearappropriateelectricalsupply,watersupply,andwaterdrainage.Adrivewayisasuitablechoice.

2 Coverthedrainandoverflowholewithtapeorastopperandfillthebathtubtothebottomoftheoverflowhole.

3 Allowbathtubtostandfor5minutes.

4 Pluginmotor/pumpandturnuniton.ConfirmthatallfeaturesfunctionasdescribedintheOperationsectionofthismanual.Donotinstallthebathtubifbathtubfailstooperateasdescribed.

5 Visuallyinspectalljointsforleaks.Donotinstallthebathtubifleaksaredetected.

6 Returnbathtubtoboxorotherwiseprotectfromdamageuntiltimeofinstallation.

1 Removethebathtubfromtheshippingcarton.Becarefulnottoscratchthesurfaceofthebathtubonexposedstaples.Removethestaplesorfoldthemintothecarton.Retainthecartonuntilsatisfactoryinspectionoftheproducthasbeenmade.Donotliftthebathtubbytheplumbingatanytime;handlebytheshellonly.

2 Inspecttheshellandbathtubcomponents.Shouldinspectionrevealanydamageordefectinthefinishorvisibledamagetoanycomponents,donotinstallthebathtub.Damageordefecttothefinishclaimedafterthebathtubisinstalledisexcludedfromthewarranty.JacuzziLuxuryBath’sresponsibilityforshippingdamageceasesupondeliveryoftheproductsingoodordertothecarrier.

3 Referanyclaimsfordamagetothecarrier.Fordefinitionsofwarrantycoverageandlimitations,refertothepublishedwarrantyinformationpackedwiththeproductorinthebackofthismanual.

CAUTION Keepbodyandhairaminimumof6˝(152mm)awayfromthesuctionfittingatalltimeswhen thehydromassagesystemisinoperation.Hairlongerthanshoulderlengthshouldbesecured closetothehead.

CAUTION Donotimmersethecontrolpanelbyoverfillingthebath.

CAUTION Toavoidinjury,usecarewhenenteringandexitingthehydromassagebathtub.

CAUTION Donotusedrugsoralcoholbeforeorduringtheuseofahydromassagebathtubequipped withaheater.Possibledrowningmayoccur.

CAUTION Donotuseahydromassagebathtubequippedwithaheaterimmediatelyfollowingstrenuous exercise.

SAVE THESE INSTRUCTIONS.JacuzziLuxuryBath("theCompany")hasobtainedapplicablecode(standards)listingsgenerallyavailableonanationalbasisforproductsofthistype.Itistheresponsibilityoftheinstaller/ownertodeterminespecificlocalcodecompliancepriortoinstallationoftheproduct.TheCompanymakesnorepresentationorwarrantyregarding,andwillnotberesponsibleforanycodecompliance.Productspecificationsaresubjecttochangewithoutnotice.

CAUTION Usethisunitonlyforitsintendeduseasdescribedinthismanual.Donotuseattachmentsnot recommendedbythemanufacturers.Donottamperwithuser-operatedcontrolsorsuch devices.

CAUTION Watertemperatureinexcessof104°F(40°C)maybeinjurioustoyourhealth.Checkand adjustwatertemperaturebeforeuse.

Page 5: Installation Manual Template - Lowe'spdf.lowes.com/installationguides/731352684654_install.pdfINSTALLATION AND OPERATION INSTRUCTIONS ... wire connector is provided on the exterior

Comfort™Collection

InstallationandOperation www.jacuzzi.com Page5

Comfort™Collection Comfort™Collection

Engl

ish

Framing and Support

Observeallgoverningcodesandordinances.

1 Properinstallationisyourresponsibility.Haveaqualifiedtechnicianinstallthisbath.

2 Installationusingaground-faultcircuit-interrupter(GFCI)isrequired.

3 Itisthecustomer’sresponsibility: •Tocontactaqualifiedelectricalinstaller. •ToassurethatelectricalinstallationisadequateandinconformancewithNationalElectricalCode(NEC).

ATechnicalSpecificationsManualhasbeenincludedwithyourbathtub.TheTechnicalSpecificationsManualwillcontainpertinentinformationregardingyourJacuzziLuxuryBathproduct.LocatetheTechnicalSpecificationsManualatthistime.

NOTES

Finishedalcovemusthavecorrectinteriordimensions,asshowninthekeydimensionsectionintheTechnicalSpecificationsManual,toproperlyinstallunit.Forthreewallalcoveinstallations,useanintegralmoldedthree-sidedtilingflangebathtub.JacuzziLuxuryBathdoesnotrecommendutilizingbathtubswithoutanintegraltilingflangeinanalcoveinstallationwhereashowerheadwouldbeinstalledabovetheunitandutilizedasashower.

•Inremodeling,ifnecessary,addstudsateachendtoprovideaverticalnailingsurfaceforthesidenailingflangesofbathfixtureproduct.

•Toavoidobstructionsduringinstallationmakesurethatsupplylines,spoutpipeandvalveplumbingdonotprojectintoalcove.

•Bathtubsrequirea6"x12"(150mmx305mm)flooropeningforthe1½"(38mm)drain,wasteandoverflow(DWO)kit.

•Besureflooropeninglocationmatchesbathtubfixturedrainlocation.

•Useofcastingplaster/plasterofparis(foundationmaterial)isrecommendedinallcommercialstructures(i.e.hotels,motels,dormitories,healthclubs,etc.).

•Theunitmustbesupportedfromthebottomofthebathtubandnotsolelyfromthebathtubrim.

Fig. 1

READALLINSTALLATIONINSTRUCTIONSCOMPLETELY.IMPROPERINSTALLATIONWILLVOIDTHEWARRANTY.

IMPORTANT

Makesurethatwallsandfloorsmeetfiresafetyrequirementsoflocalbuildingcodeand/orFHA/HUDMinimumPropertyStandards.

•PerUPCcode,accessmustbeprovidedtothepump/motoror blowerforyourspecificmodel(Figure1).Itistheresponsibilityoftheinstaller,buildingcontractor,orownertoprovideaccessforservice.Jacuzziisnotresponsibleforanycostsrelatingtoobtainingaccessforrepair.Theownershallbearsuchcostsand,ifappropriate,mustseekrecoveryfromtheinstaller.Primaryandsecondaryserviceaccesslocationsareshownintherough-indiagramscontainedintheTechnicalSpecificationsManual.

•Provideadequateventilationforcoolingandsupplysufficientairforthepump/motororblower.Donotinsulatearoundthe equipment.

(Illustrationsaboveshownwithframingexposedforclarity.)

Access Locations

AccessLocationExamples

Page 6: Installation Manual Template - Lowe'spdf.lowes.com/installationguides/731352684654_install.pdfINSTALLATION AND OPERATION INSTRUCTIONS ... wire connector is provided on the exterior

Page6 www.jacuzzi.com InstallationandOperation

Comfort™CollectionEn

glis

hComfort™Collection

Electrical Connections

Framing and Support (Cont)Subfloor

DANGER

Riskofelectricshock.ConnectonlytoacircuitprotectedbyaGFCI(Figure2).

CAUTION

Electricaloutletmustbemounted4˝(101mm)abovethefloorlineand12"max(305mm)insidefromtheedgeofthebathtub(Figure2),orinaccordancewithlocalbuildingandelectricalcodes.

Riskofcomponentoverheat.Donotuseelectricextensioncordtopowerthisunit.Operatingthepumpwithoutenoughwaterinthebathtubcancausepermanentdamagetothepump/motor.

IftheGFCIunitindicatesamalfunction,permanufacturer’sinstructions,turnOFFpoweranddonotattempttousethebathtubuntilthesourceoftheproblemhasbeenidentifiedandcorrected.

1 Preparethesubfloorforthedrainandensurethattheareaislevel.Thedrain/overflowofthebathtubextendsbelowthe bottomofthebathtub.IdentifythedrawingintheTechnicalSpecificationsManualthatcorrespondswithyourbathtub.

2 Jacuzzi’sTru-Level™baseisastandardfeatureonallbathtubs.Ifthesubfloorislevelandacontinuoussurface,noother preparationisnecessary.Proceedtothe“InstallationProcedures”section.

3 Ifthesubfloorisnotlevel,youmustleveltheentiresurfacepriortoinstallingthebathtub.

4 Ensurethatthefloorislevelandcansupportaloadof50lbs.persquarefoot.

5 Thebathtubmustremainlevelinorderforittodrainproperlyandmustmakecontactwiththelevelingmaterial.

NOTESWhenusingelectricalproducts,basicprecautionsshouldalwaysbefollowed:

•Alwaysfollowlocalbuildingandelectricalcodes.Groundingisrequired.Theunitshouldbeinstalledandgroundedbyaqualifiedelectrician.

•Adedicated,120VAC,15AmpGFCI-protectedcircuitisrequiredforthepump/motororblower.Ifthebathtubwaspurchasedwithawhirlpoolheaterinstalled,aseparate 120VAC,15AmpGFCI-protectedcircuitisrequired.Bondinglugsareprovidedonthemotorandheatertosatisfylocal electricalcodes.

Fig. 2

NOTECANADIANMODELSONLY:ThecomponentsmustbehardwiredintheJ-Boxes(supplied)thatarelocatedontheunit.1-120VAC,15AMPdedicatedGFCIprotectedcircuit

Whirlpoolw/optionalheater

AirBath

OptionalHeater

12.00"(305mm)

4.00"(101mm)

4.00"(101mm)

12.00"(305mm)

Page 7: Installation Manual Template - Lowe'spdf.lowes.com/installationguides/731352684654_install.pdfINSTALLATION AND OPERATION INSTRUCTIONS ... wire connector is provided on the exterior

Comfort™Collection

InstallationandOperation www.jacuzzi.com Page7

Comfort™Collection Comfort™Collection

Engl

ish

Installation Procedures 1 Makesureframed-inalcoveisofpropersizeperJacuzzi dimensions,square,andplumb;checkfloorforlevelness (Figure3).Rough-inshouldbekepttoaminimumuntilthe unitisonthejobsite.Measurementsmayvary+0or-.25" fromoriginalspecifications.

2 Sufficientclearancemustbeprovidedforaccesstoservice connections(pump/motor,blower,controls,heaterplumbing andelectricalhookups).

NOTEBottomsupportmaterials:Castingplaster/plasterofparis(hereinreferredasfoundationmaterials)arenotnecessarybutitsuseishighlyrecommendedforafirmerbottomsupport.

3 Inabucket,mixfoundationmaterial.Placealargemoundof plasteronthesubfloor,intheapproximatelocationofthetub bottomcenter.Themoundsshouldbeplacedhighenoughso thatwhenthetubisset,itwillcausetheplastertodisplace andspread.

Fig. 3

Fig. 5

A. Drop In Installation

1.Placeapieceofscraplumberoneachoftheendsof thecutout–thiswillbeusedasatemporarysupport priortoloweringthebathtubfullyintotheopening (Figure4).

2.Installtheunit,insertingthemotor/pumpendfirst, loweringthebathtubintotheopeningasshownin theillustration.

3.Thebathtubmustbesetlevel.Tocheck,usealevel ontopoftheledgesonbothendsoftubandontop ofthreshold(Figure5).

4.Caulkaroundtheperimeterofbathtubtosealthe spacebetweentherimandthefinisheddeck

B. 3-Wall Alcove Installation

1.Placethetubinthealcovewiththefrontskirtfirmly onthefloor.Thebathtubmustbesetlevel.Tocheck, usealevelontopoftheledgesonbothendsoftub andontopofdam(Figure6).

2.Afterlevelingtub,markeachstud(concreteorblock wall)immediatelyabovethebackhorizontalflange. Removetubfromalcove.Measurethedistance betweenthetopofthebackhorizontalflangeandthe bottomofthetubledgeapproximately1.50"(40mm). Carefullymarkthisdimensiononthebackstuds(or wall),belowthefirstmark(Figure6inset).

3.Jacuzzimandatestheinstallationofaledgerstrip forsupportundertherearledgesofbathtubsto preventshifting.Usehorizontalledgerstripalongthe entirerearledgeor“I”,“T”supportsinatleasttwo placesinverticalposition.Naila1"x3"x60" (25mmx75mmx1525mm)ledgerstripimmediately belowthelowermarksmadeonframing (Figure6-inset).

4.Replaceunitintoalcovewithfrontskirtfirmlyon floor.Makecertainthatbackledgeoftubrestsfirmly onledgersupports.Levelunitandshimledgerif necessary.Thebathtubmustbelevel.

ScrapLumber

Level

Level

Fig. 4

Fig. 6TopofLedgerStrip

LedgerBoard

1.50"

Page 8: Installation Manual Template - Lowe'spdf.lowes.com/installationguides/731352684654_install.pdfINSTALLATION AND OPERATION INSTRUCTIONS ... wire connector is provided on the exterior

Page8 www.jacuzzi.com InstallationandOperation

Comfort™CollectionEn

glis

hComfort™Collection

Installation Procedures (Cont)

Fig. 7

FinishSurfaceConcreteBoard

Silicone

Skirt

4 Whenotherthancementitiousbackerboardistobeused, furringstripsasthickasnailingflangesarerecommendedfor installationonstudsabovetheinstalledunittoassurewalls willbeflush.100%siliconesealantwithmildewresistant propertiesshouldbeappliedbetweenthebackerboardand horizontalsurfaceofunit(Figure7).Thenfinishedwall materialscanbeapplied.5 Finishingofothertradesshouldbedoneinconformancewith applicablecodesandgenerallyacceptedbuildingpractices.

6 Useaholesaw(finetoothorabrasivegritcuttingedge)to drillholesfordeckmountedtubfittings.

7 Connectflexwatersupplylinestofaucet,connectbathtub drainsandplugpowercordsintoGFCIoutlets.

8 TurnonthepowersupplytothededicatedGFCIprotected circuitsandchecksystemoperation.

9 Caulkaroundtheperimeterofbathtubtosealthespace betweentherimandthefinisheddeck.

5.Whenfasteningwoodframing,pre-drillflangeswitha⅛"(5mm)carbidebitandfastenusing#8x1½"(38mm)self-tapping sheetmetalscrews;toconcrete/blockwallsuse1"(25mm)concretenailswithnailingtoolorimpact.

NOTE Pre-drillingandnailingflangesisrecommendedtoavoidcrackingoftheacrylicunit.Siliconethetopofeachfastenerto insurewatertightness.

6.Spot-fastenthetwobottomcornersandthetwotopcornersoftheverticalsidenailingflange.

7.Nail/fastenateachstudthroughthetopsideflangesateachstud16"(405mm)oncenter,workingfrombothendstoward backcenter.Completethefasteningthroughverticalsideflange,approximately8"(205mm)oncenter.

CAUTIONApplyacontinuousbeadofsiliconesealantaroundtheentireseambetweenthecounterandthebathtubrim.Allowsealanttocureaccordingtomanufacturer’sinstructions.

Undermount Installation

Template

BathtubRim

A BC

D

Fig. 7

TemplateCounterFig. 7

Installdrain/overflowaccordingtothemanufacturer’sinstructions.

Watertightinstallationofthedrainistheinstaller’sresponsibility.DrainleakageisexcludedfromtheJacuzziLuxuryBathwarrantyofthisproduct.

TurnoffpowersupplytodedicatedGFCIprotectedcircuits.

Installtheunitindesiredlocation.DONOTuseplumbingfixturesorlinestocarryorlowertheunit.

Inspectallfittings,plumbing,andcontrollinesafterinsertingtoinsurethecomponentsarenotdamagedordisconnected.

Alignthebathtubandconnectthedrain.

Insulationmaybeplacedwithinthebathtubsurround.

Provideadequateventilationaroundthemotor/pumptoensuresufficientairflowandcooling.

1

2

3

4

5

6

Page 9: Installation Manual Template - Lowe'spdf.lowes.com/installationguides/731352684654_install.pdfINSTALLATION AND OPERATION INSTRUCTIONS ... wire connector is provided on the exterior

Comfort™Collection

InstallationandOperation www.jacuzzi.com Page9

Comfort™Collection Comfort™Collection

Engl

ish

Whirlpool Operation

General Operation Information

CleanupToavoiddullingandscratchingthesurfaceofthebathtub,neveruseabrasivecleaners.Formostsoiledsurfaces,amildliquiddetergentandwarmwaterissufficient.Thefollowingisalsorecommended:

• Removespilledplasterwithawoodorplasticedge.Spotsleftbyplasterorgroutcanberemovediflightlyrubbedwith detergentonadampclothorsponge.Donotusemetalscrapers,wirebrushesorothermetaltools,astheywilldamagethe bathtub’ssurface.• Paint,tar,orotherdifficultstainscanberemovedwithFantastik®orsoapywater.• Minorscratcheswhichdonotpenetratethecolorfinishcanberemovedbylightlysandingwith600-gritwet/drysandpaper. Youcanrestoretheglossyfinishtotheacrylicsurfaceofthebathtubwithaspecialcompound,Meguiar’s#10MirrorGlaze.If thatisnotavailable,useautomotiverubbingcompoundfollowedbyanapplicationofautomotivepastewax.• Majorscratchesandgougeswhichpenetratetheacrylicsurfacewillrequirerefinishing.CallJacuzziLuxuryBathtofinda serviceagentinyourarea.

AllbathtubsmanufacturedbyJacuzziLuxuryBatharedesignedfor“fillanddrain,”whichmeansthebathtubshouldbedrainedaftereachuseandfilledwithfreshwaterbythenextbather.Thisisahealthprecaution,asthesebathtubsarenotdesignedtoholdwatercontinuouslylikepoolsorspas.

Closethedrainandfillthebathtubuntilwaterisatleast1˝to2˝(25mmto51mm)abovethehighestjetorairinjector(seewaterlineindicatedintheillustration-Figure8).Donotturnonthewhirlpoolorairbathsystematanytimeifthejetsorairinjectorsarenotcompletelyimmersedinwater.Runningthewhirlpoolorairbathsystemwhenthereisinsufficientwaterinthebathtubcouldresultinwatersprayingoutsidethebatharea.

NOTE Whenexitingthebathtub,thewaterlevelwilldropbelowthejetswhichcouldresultinwaterbeingsprayed outoftheunit.Topreventthis,youmustturnunitOFFbeforeexitingbathtub.

Fig. 8

Fig. 9ON: Pressthe buttononcetoturnthewhirlpoolsystemON.

OFF: Pressthe buttonasecondtimetoturnthewhirlpoolsystemOFF.

Filltoatleast1˝to2˝abovehighestjet

Undermount Installation Cont. Cutdeck/countertofitusingtheundermounttemplate

providedasfollows:

• Positionthetemplatesothatthedesiredundermount guidelinesarealignedwiththerimedgeasshown.• Usingagreasepencil,markthecenterlines(denoted by ontemplate).Removetemplate.• Measurethedistancefromthewall,orotherfixedpoint, tothecenterlines.

Affixcountertobathtub.Cleananydirtordebrisfromthetopofthebathtubrim.Applyabeadofsiliconesealantaroundtheentirerimofbathtub.

Donotuseanadhesiveoradhesivesealanttosecurethecountertothebathtub.Ifmaintenanceorremodelingisrequired,thecountermayhavetoberemoved.Adhesivewillpermanentlybondthecountertothebathtub.Carefullypositionthedeck/counteroverthebathtub.Followmanufacturer’sinstructionstodeterminecuretime.

Applyacontinuousbeadofsiliconesealantaroundtheentireseambetweenthecounterandthebathtubrim.Allowsealanttocureaccordingtomanufacturer’sinstructions.

TurnonthepowersupplytothededicatedGFCIprotectedcircuitsandchecksystemoperation.

7

8

9

10

Page 10: Installation Manual Template - Lowe'spdf.lowes.com/installationguides/731352684654_install.pdfINSTALLATION AND OPERATION INSTRUCTIONS ... wire connector is provided on the exterior

Page10 www.jacuzzi.com InstallationandOperation

Comfort™CollectionEn

glis

hComfort™Collection

Whirlpool Operation Cont.

Decrease Speed

Increase Speed

Blower OperationAir Bath System

ON: Pressthe buttononcetoturntheblowerON.

Theblowerwillstartonhighspeed(onfirstuse).

OFF: Pressthe buttonasecondtimetoturntheblowerOFF.

NOTE

Thelastblowersettingusedisrememberedbythesystemandwillautomaticallyresumeuponnextuse.

Press the button to increase blower speed.

Thereare5blowerintensities.Eachpushandreleaseofthe buttonwillincreaseblowerintensitythrough5incrementalsteps.

Alternately,ifthe buttonisdepressedandheld,theblowerintensitywillincreasethrougheachofthe5blowerintensities,stoppingwhenthe buttonisreleased.

Press the button to decrease blower speed.

Thereare5blowerintensities.Eachpushandreleaseofthe buttonwilldecreaseblowerintensitythrough5incrementalsteps.

Alternately,ifthe buttonisdepressedandheld,theblowerintensitywilldecreasethrougheachofthe5blowerintensities,stoppingwhenthe buttonisreleased.

Fig. 12

®

®

Whirlpool Operation w/ChromatherapyPress button 1st time:TurnscoloredlightingON,use buttonstostartcolorscrollorselectalternatecolor.

Press button 2nd time:TurnswhitelightingON,use buttonstoselectintensityofwhitelight.

Press button 3rd time:TurnsalllightingOFF.

Fig. 11

Colored Lighting OperationThecoloredlightingdefaultisconstantblue.Pressingthe buttonactivatescolorscrollinthisorder:blue,teal,green,yellow,orange,red,pink,purpleandthenreturnstoblueandcontinuouslyrepeats.Tostoponaselectedcolor,pressthe buttonagain.Pressingthe buttonactivatescolorscrollinthisorder:blue,purple,pink,red,orange,yellow,green,tealandthenreturnstoblueandcontinuouslyrepeats.Tostoponaselectedcolor,pressthe buttonagain.

White Lighting OperationTherearefivewhitelightintensities.Pressthe buttontoincreaselightintensity.Pressthe buttontodecreaselightintensity.

Direction (Figure10A)Tochangethedirectionofthewaterflow,swivelthejetnozzletothedesiredangle.

Water Force (Figure10B)Increasetheforceoftheflowbyrotatingthejetfacetotheleft(counterclockwise).

Decreasetheforceoftheflowbyrotatingthejetfacetotheright(clockwise).

CAUTIONNeverrunthewhirlpoolsystemwithallthejetsclosed.

Water ForceDirection

Fig. 10A Fig. 10B

Page 11: Installation Manual Template - Lowe'spdf.lowes.com/installationguides/731352684654_install.pdfINSTALLATION AND OPERATION INSTRUCTIONS ... wire connector is provided on the exterior

Comfort™Collection

InstallationandOperation www.jacuzzi.com Page11

Comfort™Collection Comfort™Collection

Engl

ish

Daily Purge

Purging the Air BathTheairbathblowerwilloperatefor20-minutesandthenautomaticallyshutofftoendthebath,unlesspowerismanuallyturnedoff.Ineithercase,twentyminutesaftertheblowerhasshutdown,theblowerwillturnONfora1-minutedryingcycletoblowoutanywaterremainingintheairchannel.

Ifthebathisusedwithoutthebloweroperating(showeringorbathingwithoutusingtheblower),initiatethe1-minutedryingcyclemanuallybyuseoftheON/OFFswitch.TurntheswitchONandOFFagainasyouexitthebathandthedryingcyclewilloccurintwentyminutes.

To Acitvate:Holdingthe buttonfor5-secondswhentheblowerisoffactivatesthedailypurge.Theblowerwillstarteverydayatthesametimefor1-minute.Oncethedailypurgeisactivated,theblowerwillcomeonfor1-second,turnofffortwo-seconds,comeonfor1-secondandthenturnoff.

To Deactivate:Holdingthe buttonfor5-secondswhentheblowerisoffdeactivatesthedailypurge.Whenthedailypurgeisdeactivated,theblowerwillcomeonfor1-secondandthenturnoff.

Toremoveaccumulationsofbathtubresiduefromthewhirlpoolsystem,itisrecommendedthatawhirlpoolbathtubbecleanedatleasttwiceamonth.Forbestresults,however,werecommendthatyoucleanyourwhirlpoolbathtubaftereachuseusing,SystemsClean™,ourexclusivetwo-partplumbingsystemcleanermadespecificallyforwhirlpoolbathtubs.SystemsClean™isavailablethroughanauthorizedJacuzziWhirlpoolBathDistributororbycallingusdirectat1-800-288-4002.

Purging the Whirlpool System

High-Limit Switch

Vacuum Switch

In-Line Maintenance Heater (Whirlpool models only)TheheaterturnsONautomaticallyanytimewhirlpooloperationisactive.Heateroperationisnotdisplayedonthecontrolpanel.Thereisavisibleindicatorlightontheheateritselfthatsignifiestheheaterisoperating.Theheaterwillhelpmaintainthetemperatureofthewaterinthebathtub(Figure14).

TheheaterisequippedwithapresetvacuumswitchwhichwillnotallowtheheatertoturnONifthepumpisnotrunningandwaterisnotflowingthroughthewhirlpoolsystem.

TheheaterincludesanexclusiveHigh-Limitswitch.Thissafetycircuitwillnotfalsetripfromhottapwater.ItwillonlyturnOFFtheheaterifthethermostatfails.Toreset,pressthebutton.Ifthehigh-limittripsfrequently,pleasecontactusatwww.jacuzzi.com,orat1-800-288-4002.

PUSH TO RESET

OVER HEATPROTECTION

HEATER ON

HighLimitReset

HeaterOn

Fig. 14

Cleaning

Ifyouwanttouseanykindofbathtubadditive,useonlyasmallamountoflow-foamingpowderorcrystalsubstance;thewhirlpoolactionintensifiesthefoamingpropertiesofsoaps.

Theuseofcertainbathtuboils,bubblebaths,andbathtubadditivesmayincreasethelevelofaccumulationsofbathtubresidueinthewhirlpoolsystemandmaycausefalsereadingofthewaterlevelsensors.Ifexcessaccumulationspersist,youshoulddiscontinueuseoftheseproducts.

Toremoveaccumulationsofbathtubresiduefromthewhirlpoolsystem,itisrecommendedthatabathtubbecleanedregularly.Forbestresults,however,werecommendthatyoucleanyourwhirlpoolbathtubaftereachuseusingSystemsClean™,ourexclusivetwo-partplumbingsystemcleanermadespecificallyforwhirlpoolbathtubs.SystemsClean™isavailablethroughanauthorizedJacuzziLuxuryBathDistributororbycallingusdirectat1-800-288-4002ormaybepurchasedonlineatwww.jacuzzi.com.

CAUTION Do not use oil or oil-based bathtub additives. Never use abrasive, or caustic, household cleaners on any Jacuzzi Luxury Bath product.

Page 12: Installation Manual Template - Lowe'spdf.lowes.com/installationguides/731352684654_install.pdfINSTALLATION AND OPERATION INSTRUCTIONS ... wire connector is provided on the exterior

Page12 www.jacuzzi.com InstallationandOperation

Comfort™CollectionEn

glis

hComfort™Collection

To remove the skirt panel -Graspanedgeoftheskirtpanelandpulltoseparate.

To reinstall the skirt panel (Figure16) -Alignthesix(6)postsonthepanelwiththesix(6)receptorsocketsonthetubandpressintoplace.

Skirt Panel Adjustment (Figure17) -Insertastandardscrewdriverintothereceptorsocket,throughtheslotattherear.Turnclockwisetotightenandcounter-clockwisetoloosen.

Fig. 16

ReceptorSocket

Post

Fig. 17

InteriorView

ExteriorView

ReceptorSocketSlot

Skirt Panel Installation (Select skirted models only)

Whirlpool Suction Cover/Strainer Maintenance

MaintenanceTocleanyourbathtub,simplyuseamild,nonabrasiveliquiddetergentsolution.YoucanprotectandrestoretheglosstoadulledacrylicsurfacebyapplyingMeguiar’s#10MirrorGlaze,aproductspecificallydesignedforuseonacrylicfinishes.IfMeguiar’sisnotavailable,useafinegradeautomotiverubbingcompoundfollowedbyanapplicationofclearautomotivepastewax.

Minorscratcheswhichdonotpenetratethecolorfinishcanberemovedbylightlysandingwith600-gritwet/drysandpaper.RestoretheglossusingMeguiar’sMirrorGlazeorautomotivepastewax.Majorscratchesandgougeswhichpenetratetheacrylicsurfacewillrequirerefinishing.CallJacuzziLuxuryBathtofindaserviceagentinyourarea.

Cleanthewhirlpoolsuctioncover/strainerofhairanddebriswhennecessary(Figure15).

1 Insertandpushflatheadscrewdriverintothecenterofthesuctioncoverandremovecover.

2 Cleanthecoverbybackflushingdebrisfromtheholes.

3 Replacethesuctioncoverimmediatelyaftercleaning.

Keephairaminimumof6.00"(152mm)awayfromthesuctionfittingatalltimeswhenthewhirlpoolsystemisoperating.Hairlongerthanshoulderlengthshouldbesecuredclosetothehead,orabathingcapshouldbeworn.

Donotoperatethewhirlpoolsystemwiththesuctioncover/strainerremoved!Itisasafetydeviceandmustalwaysbeinplaceonthesuctionfittingtominimizethepotentialhazardofhairandbody

Fig. 15

FlatHeadScrewDriver

SuctionCover

WARNING

NOTETheskirtinstallationlistedinthissectionareusedfortheselectbathtubonly.AllotherComfortCollectionbathtubswillutilizemagnetstosecuretheskirtpanels.

Page 13: Installation Manual Template - Lowe'spdf.lowes.com/installationguides/731352684654_install.pdfINSTALLATION AND OPERATION INSTRUCTIONS ... wire connector is provided on the exterior

Comfort™Collection

InstallationandOperation www.jacuzzi.com Page13

Comfort™Collection Comfort™Collection

Engl

ish

Troubleshooting Procedures

Iftheunitiswithinthewarrantyperiod,contactJacuzziLuxuryBathServiceSupportat1-800-288-4002withyourbath’sserialnumberbeforeworkisstarted.TheserialnumberislocatedontheSpecification/SerialNumberPlate(theplateislocatedbehindtheequipmentarea).

PROBLEM PROBABLECAUSES REMEDY

Whirlpool-Pump/motordoesnotstart

Whirlpool-Pump/motorshutsoffbyitselfbeforetimeelapses

Whirlpool-Pump/motoroperatesbutnofullyadjustablejetsarefunctioning

Whirlpool-Waterleakagefrompumpunions

Nopowertopump/motorPump/motornotpluggedinPump/motorfaulty

Motorthermalprotectionhasdeactivatedpump/motorduetooverheating(supplyvoltagelow)

GFCItripped

Inadequatesupplywiring

ResetGFCIInsertplugsecurelyintooutletEnsurethecontrolpanelisconnectedtocontrolboxContactJacuzziLuxuryBath@800-288-4002

Letmotorcool;thermalprotectionwillreset.Checkforproperventilation(checksupplyvoltage)

ResetGFCI.Ifitcontinuestotrip,donotusethisunit.Disconnecttheunitandhavetheproblemcorrectedbyalicensedelectricianbeforeusing.

Consultalicensedelectriciantocorrectthewiringunit.

Jetsareclosed

Suctioncover/strainermaybeclogged

Openjetsbyrotatingcounter-clockwise

WiththemotorturnedOFF,removethesuctioncover/strainerandremoveanydebris.Replacethesuctioncoverbeforeoperating

Overtightened,O-ringmaybepinchedorimproperlyseated,undertightened

Loosenunions,checkandreseatO-ring.IfO-ringhasbeenpinchedoutofshape,replace(refertonumberbelow).Whentighteningunionnuts,handtightenonly.

PressResetbuttononheaterWaternotmaintainingtemperature HighLimitswitchonheaterhasbeentripped

NOTE

AirBath-Blowerdoesnotstart

AirBath-Blowershutsoffunexpectedly

NopowertoblowerBlowernotconnectedBlowerfaulty

ResetGFCIand/orbreakerEnsureplugisfullyinoutletEnsurecontrolpanelisconnectedtocontrolboxEnsurecontrolboxisconnectedtocontrolpanelContactJacuzziLuxuryBath@800-288-4002

20minutetimerhaselapsedGFCItrippedInadequatesupplywiringImproperventilation

TurnonblowerResetGFCI.Ifitcontinues,totrip,donotusetheunitConsultalicensedelectriciantocorrectContactJacuzziLuxuryBath@800-288-4002

AirBath-Bloweroperatesbutairisnotexitingalloftheholes

Obstructedairholes Removedebriswithatoothpickortoothbrush

Chromatherapylightsdonotoperate Connectorhascomeloose ContactJacuzziLuxuryBath@800-288-4002

Page 14: Installation Manual Template - Lowe'spdf.lowes.com/installationguides/731352684654_install.pdfINSTALLATION AND OPERATION INSTRUCTIONS ... wire connector is provided on the exterior

Page14 www.jacuzzi.com InstallationandOperation

Comfort™CollectionEn

glis

hComfort™Collection

PRODUCTSPECIFICATIONSARESUBJECTTOCHANGEWITHOUTNOTICE.

USETECHNICALSPECIFICATIONSMANUALSUPPLIEDWITHPRODUCT.

Jacuzzi®LuxuryBathhasobtainedapplicablecode(standards)listingsgenerallyavailableonanationalbasisforproductsofthistype.Itistheresponsibilityoftheinstaller/ownertodeterminespecificlocalcodecompliancepriortoinstallationoftheproduct.Jacuzzi®LuxuryBathmakesnorepresentationorwarrantyregarding,andwillnotberesponsibleforanycodecompliance.

Jacuzzi®LuxuryBath

14525MonteVistaAvenue

Chino,California,91710

1-800-288-4002

www.jacuzzi.com

Ifyouneedareferralforaservicecompanynearyou,orneedassistancewithoperationormaintenance-relatedquestions,pleasecallourServiceSupportDepartmentat1-800-288-4002.Visitourwebsiteathttp://www.jacuzzi.com/forproducts,services,andanonlinecopyoftheseInstallationandOperationInstructions.

Whenrequestingserviceortechnicalassistancepleasehaveavailableboththemodelandserialnumberofyourunit.Thisinformationcanbeobtainedfromtheproductregistrationcardprovidedwithyourunit.Ifthecardhasbeenmisplaced,thisinformationcanbeobtainedfromthespecification/serialnumberlabelontheunititself.Thelabelislocatedonthewallofthebathtubnearthepump/motor.

SPECIFICATION/SERIAL NUMBER LABEL

MODEL: XXXXXXX

NAME: XXXXX

COLOR: XXXXX

MFG#: XXXXX

SER#: XXXXXX

AppropriateSafetyComplianceLogosforyourunit.

ApplicableElectricalSpecificationsforyourunit.

Electricalspecificationsprintedinthisarea.

MadeintheUSA

XXXX-XXXXXCoreNumber,SerialNumber

Youwillfindyourserialnumberhere

Authorized Service

Page 15: Installation Manual Template - Lowe'spdf.lowes.com/installationguides/731352684654_install.pdfINSTALLATION AND OPERATION INSTRUCTIONS ... wire connector is provided on the exterior

Comfort™Collection

InstallationandOperation www.jacuzzi.com Page15

Comfort™Collection Comfort™Collection

Engl

ish

WARRANTY COVERAGEJacuzziLuxuryBath(the“Company”)offersthefollowingexpressedlimitedlifetimewarrantytotheoriginalpurchaserofanyJacuzzi®LuxuryBathproductsprovidedintheCompany’sComfort,PureAir®,PureAir®II,andLuxury™collections("Bath")whopurchasestheBathforpersonalorsinglefamilyresidentialuse(“User”):TheCompanywillrepairorreplace,atitssoleoption,theBathoritsequipmentinaccordancewiththefollowingtermsandconditions.Thiswarrantydoesnotapplytonon-brandedBathproductsmanufacturedbytheCompany.

LIFETIME WARRANTY ON BATHSTheCompanyextendstotheUseroftheBathanon-transferablelimitedlifetimewarrantythattheshellwillmaintainitsstructuralintegrityandconfigurationandbefreeofwaterlossduetoadefectinthebathtubshell.Thiswarrantycoversonlythebathtubshellandthemanufacturerinstalledpump,jets,controls,andbloweragainstdefectsinmaterialorworkmanship.Thiswarrantydoesnotapplytoanydisplaymodelsortoanyoptionsoraccessorieswhicharecoveredunderourlimitedninety(90)daywarrantysetforthbelow.WarrantycoveragebeginsonthedatetheunitwasoriginallypurchasedbytheUseranduponreceiptbytheCompanyofacompletelyfilledoutWarrantyRegistrationCardasdescribedbelow.

2 YEAR LABOR WARRANTY FOR ALL FACTORY INSTALLED COMPONENTSOurlimitedlaborwarrantyisforaperiodoftwo(2)yearsfromthedatetheunitwasoriginallypurchasedbytheUser,butnotmorethanThree(3)Yearsfromdateofmanufacture.Allfactoryinstalledcomponents(e.g.,pump,motor,blower,andplumbing)arecoveredunderourlaborwarrantyagainstfailureduetodefectsinmaterialsandworkmanship.

NINETY DAY (PARTS ONLY) LIMITED WARRANTY ON OPTIONS AND ACCESSORIESOurlimitedwarrantyonoptionsandaccessoriesisforninety(90)daysforpartsonly.Ourwarrantycoversoptionsandaccessoriesmanufactured(e.g.,drainsfillspoutkits,trimkits,skirts,videomonitors,plasmatelevisionscreens,CDandMP3playersandothermusicandvideodevicesandoptionalheaters)againstdefectsinmaterialorworkmanship.WarrantycoveragebeginsonthedatetheoptionoraccessorywasoriginallypurchasedbytheUser.Theseitemsmaybecoveredbyamanufacturer'swarrantywhichmayhavealongerdurationthanthislimitedwarranty.PleaseconfirmwiththemanufacturerthedurationoftheappropriatewarrantyforOptionsandAccessories.

WARRANTY LIMITATIONSOurlimitedwarrantydoesnotcoverdefects,damage,orfailurecausedbythecommoncarrier,installer,user,orotherpersons,pets,orrodents,orresultingfrom,withoutlimitation,anyofthefollowing:carelesshandling(liftingunitbyplumbing,abradingfinish,etc.)includingitsownnegligence;modificationofanytypeforanyreason(includingmodificationtomeetlocalcodes);improperinstallation(includinginstallationnotinaccordancewithinstructionsandspecificationsprovidedwiththeunit);connectionssuppliedbytheinstalleroftheequipment;impropervoltagesupplyorunauthorizedelectricalmodification;misuse;incorrectoperation,orlackofproperroutinemaintenance;operationoftheunitwithoutspecifiedminimumamountofwateroratinappropriatewatertemperature;useofabrasiveorimpropercleaners;oractsofGod,suchaslightning,floods,earthquakes,etc.

Inaddition,THECOMPANYWILLNOTBERESPONSIBLEFORINCIDENTALORCONSEQUENTIALDAMAGESorlossesarisingfromanycause(e.g.,waterdamagetocarpet,ceiling,tiles,marble,lossofuse,etc.)includingitsownnegligence;damagesto,respecting,orresultingfrom:platedpartswhenpooland/orspachemicalsareusedintheunitorhardwaterconditions;optionalbathequipmentnotmanufacturedbytheCompanybutsuppliedbyDealer,installerortheCompany;theunit'spriorusageasanoperationaldisplay;ordefectsthatshouldhavebeendiscoveredbeforeinstallation.

Thislimitedwarrantydoesnotinclude:labor,transportation,orothercostsincurredintheremovaland/orreinstallationoftheoriginalunitand/orinstallationofareplacementunit;anycostsrelatingtoobtainingaccessforrepair;orlossofusedamage,includinglossofsales,profitorbusinessadvantageofanykindunderanycircumstances.Bathunitsareexcludedfromanywarrantycoverageifanyaddition,deletion,ormodificationofanykindwhatsoeverhasbeenmadetotheunit(ortoanycomponent).WarrantycoverageisprovidedintheUnitedStatesofAmericaandCanadaonly.

EXCLUSION OF IMPLIED WARRANTIESIMPLIEDWARRANTIESOFMERCHANTABILITYANDFITNESSFORAPARTICULARPURPOSEAREDISCLAIMEDALTOGETHERORTOTHEFULLESTEXTENTALLOWEDBYLAW.NOTICE:Thiswarrantygivesyouspecificlegalrights,andyoumayalsohaveotherrightswhichvaryfromstatetostate.TherearenowarrantiesapplicabletoJacuzziLuxuryBathproductsexceptasexpresslystatedhereinorasimpliedbyapplicablestateandfederallaws.TheCompanywillnotberesponsibleforanystatementsorrepresentationsmadeinanyformthatgobeyond,arebroaderthanorareinconsistentwithanyauthorizedliteratureorspecificationsfurnishedbytheCompany.Somestatesdonotallowlimitationsonhowlonganimpliedwarrantylasts,ortheexclusionorlimitationofincidentalorconsequentialdamages,sotheabovelimitationsandexclusionsmaynotapplytoyou.

WarrantyLimited Lifetime Warranty on Jacuzzi Luxury Branded Baths for the Comfort, Pure Air®, Luxury, Salon™ Spa, and Pure Air® II Collections

Page 16: Installation Manual Template - Lowe'spdf.lowes.com/installationguides/731352684654_install.pdfINSTALLATION AND OPERATION INSTRUCTIONS ... wire connector is provided on the exterior

Page16 www.jacuzzi.com InstallationandOperation

Comfort™CollectionEn

glis

hComfort™CollectionRETURN OF WARRANTY REGISTRATION

Toregisteryourproduct,pleasegotoourweb-siteJacuzzi.com,clickonBathandShowers,thenselectONLINEWARRANTYREGISTRATIONfromthetopofthepage.YouwillthenbepromptedtoenteryourproductSerialNumberfollowedbyyourwarrantyregistrationinformation.Oryoumayalsoregisterbycompletingtheregistrationbelowandmailingittojacuzziattheaddressprovidedbelow.

TheattachedWarrantyRegistrationMUSTbefilledoutbythepurchaserwithinthirty(30)daysfrompurchaseandreceivedbyJacuzziLuxuryBathinorderforthiswarrantytobecomeeffective.

RESPONSIBILITIES OF OTHERSInspectingtheunitpriortoinstallationistheresponsibilityoftheinstallerorbuildingcontractorwhoactsonbehalfoftheUser.Theyareresponsibleforensuringtheunitisfreeofdefectordamage.Noticesareplacedonandintheunitandontheshippingcartonadvisingtheinstallerofthisresponsibility.Intheeventofaproblem,theunitmustnotbeinstalled.TheCompanyisnotresponsibleforfailuresordamagethatcouldhavebeendiscovered,repaired,oravoidedbyproperinspectionandtesting(includingproperwatertesting)priortoinstallation.

Damageoccurringintransitistheresponsibilityofthecarrier.TheUserorinstallerMUSTopenthecrateandinspecttheunitfordamagewhenitisdelivered.Ifdamageisdiscovered,itmustbereportedimmediatelytothesellerandthecarrierinwriting,andaninspectionrequested.Failureofthecarriertorespondshouldbereportedtothesellerandthecarrier.Yourfreightclaimsshouldbefiledpromptlythereafter.

Damageoccurringtotheunitduringinstallationistheresponsibilityoftheinstallerand/orbuildingcontractoranddamageoccurringthereafteristheresponsibilityoftheuser.

FailureofanyoptionalequipmentisthesoleresponsibilityoftheequipmentmanufacturerexceptasprovidedaboveandshallnotextendtoorapplytoanyreplacementpartsfortheOptionsandAccessories.Anyreplacementpartsshallbecoveredbytheoriginalequipmentmanufacturer.

TheDistributororDealerisresponsibleforknowinglocalcoderequirementsandnotifyingtheinstallingcontractorand/orUseroftheserequirementsatthetimeofpurchase.TheCompanyisnotresponsibleforcoststomodifyanyproducttoobtainanycodeapproval,suchascity,county,orstatebuildingcodesinU.S.A.ormunicipalorprovincialcodesinCanada.

WARRANTY SERVICEForthecustomer'sbenefit,theCompanymaintainsalistofindependentservicepersonneltoperformrequiredwarrantyservicerepairs.SuchfirmsarenotagentsorrepresentativesoftheCompanyandcannotbindtheCompanybywordsorconduct.

TheCompanywillprovidethewarrantyservicedescribedabovewhenthefollowingconditionshavebeenmet:thefailureisofthenatureortypecoveredbythewarranty;theUserhasinformedanAuthorizedJacuzziLuxuryBathServiceAgentorWarrantyServiceDepartmentRepresentativeofthenatureoftheproblemduringthewarrantyperiod;conclusiveevidence(e.g.,proofofpurchaseorinstallation)isprovidedtotheforegoingbytheuserprovingthatthefailureoccurredorwasdiscoveredwithinthewarrantyperiod;anauthorizedindependentservicepersonorCompanyrepresentativehasbeenpermittedtoinspecttheunitduringregularbusinesshourswithinareasonabletimeaftertheproblemwasreportedbytheUser.Inordertoobtainwarrantyservice,contactJacuzziLuxuryBathat:

jacuzzi.comor

WarrantyServiceDepartment14525MonteVistaAvenueChino,California91710Call:1-(800)288-4002

Toobtainwarrantyreplacementforfactory-installedcomponentsforCompanysuppliedoptionsandaccessoriesmanufacturedandsuppliedbytheCompany,callorwritetheabove.Provideadescriptionoftheproblemandproofofpurchase.Youwillbeinstructedhowtoobtainreplacementsandwheretoreturn,atyourexpense,thefailedcomponent(s),option(s),oraccessory(ies).

Allreplacementparts,equipment,andrepairsshallassumetheremainingwarrantyperiodofthepart(s)replaced.

TheCompany'swarrantyobligationshallbedischargedupontenderofreplacementorrepair.Thecustomer'srefusaltoacceptthetenderterminatestheCompany'swarrantyobligation.

Jacuzzi®LuxuryBathLD56000

Ninety-DayPartsOnly

LimitedWarrantyOn

Accessory(ies)

Page 17: Installation Manual Template - Lowe'spdf.lowes.com/installationguides/731352684654_install.pdfINSTALLATION AND OPERATION INSTRUCTIONS ... wire connector is provided on the exterior

Comfort™Collection

InstallationandOperation www.jacuzzi.com Page17

Comfort™Collection Comfort™Collection

Engl

ish

Jacuzzi®LuxuryBath

14525MonteVistaAvenue

Chino,C

alifornia91710

Page 18: Installation Manual Template - Lowe'spdf.lowes.com/installationguides/731352684654_install.pdfINSTALLATION AND OPERATION INSTRUCTIONS ... wire connector is provided on the exterior

Page18 www.jacuzzi.com InstallationandOperation

Comfort™CollectionEn

glis

hComfort™Collection

Espa

ñol

WARRANTY REGISTRATION CARD

Tocompleteyourregistration,visitourwebsiteatwww.jacuzzi.comorfilloutandmailthiscardtotheaddressprintedontheothersidewithinthirty(30)daysfromdateofpurchaseinorderforthiswarrantytobecomeeffective.Purchaser'sName______________________ Purchaser'sAddress____________________ City__________________State__ Zip____HomePhone:__________________ CellPhone: Email:________________________________ DateofPurchase________ ModelName__________________________SerialNumber_________________________Dealer'sName_________________________Dealer'sAddress_______________________1.HowdidyoufirsthearaboutthisJacuzzi®product? ()Advertisement()ArticleinMagazine/Newspaper ()VisitedDealer/PlumbingSupplier()YellowPages ()Builder/Plumber/Remodeler()Decorator/Architect ()VisitedRetailer/HomeCenterStore ()WordofMouth...Friend/Relative/Acquaintance ()Other(PleaseDescribe)______________2.Whofirstgaveyouspecificinformationaboutthisproduct(specifications,prices,etc.)? ()Dealer/PlumbingSupplier()Builder()Remodeler ()PlumbingContractor()Retailer/HomeCenterStore ()Decorator/Architect()AlreadyInstalled3.Whatwasthemainreasonforpurchase? ()Styling()WarrantyService()ProductFeatures ()BrandName()Price()Hydrotherapy ()HomeResale_______________________ ()Other_____________________________4.Whofinallydecidedwhichproductyouwouldbuy? ()Self()Spouse()SelfandSpouseTogether ()OtherFamilyMember()Designer/Architect ()Builder/Plumber/Remodeler()AlreadyInstalled5.Whoinstalled?()Alreadyinstalled/NewHome ()Contractor/Plumberwhenremodeling ()Self/Spousewhenremodeling ()Other_____________________________6.Whatisthecurrentmarketvalueofthisproperty? Pleaseestimate$ _____________________7.Whatistheageoftheheadofthehousehold?Years8.Whatothermanufacturersdidyouconsider? ()Eljer()Lasco()PricePfister()AquaGlass ()Kohler()AmericanStandard()Sterling ()Other(Specify)_____________________9.Howlongdidyoushopbeforepurchasingunit? ()1day ()2months-6months ()2-7days ()6months-1year ()1week-2weeks ()1year-2years ()2weeks-4weeks ()+2years ()1month-2months10.Approximatelyhowlonghaveyoulivedinthishome ?11.Pleaseindicate,approximately,thetotalannualincomeofyourhousehold. ()Upto$24,999()$50,000to$74,999 ()$25,000to$29,999()$75,000to$99,999 ()$30,000to$39,999()$100,000to$149,999 ()$40,000to$49,999()$150,000andAbove12.Wasyourpurchaseprocess? ()Veryeasy()Easy()Difficult()VeryDifficult13.HowtechnicallyawarewereyouofthepatentedJacuzzi®jetsystempriortoyourpurchase? ()Notaware()Somewhataware()Veryaware

Jacuzzi®LuxuryBathLD56000

Ninety-DayPartsOnly

LimitedWarrantyOn

Accessory(ies)