Harman® • P35i-C Installation Manual_R5 • 2019 -___ • 03/211
8390-784i
Installation ManualInstallation and Appliance Setup
INSTALLER: Leave this manual with party responsible for use and
operation.OWNER: Retain this manual for future reference.
To obtain a French translation of this manual, please contact
your dealer or visit www.harmanstoves.comPour obtenir une
traduction française de ce manuel, s’il vous plaît contacter votre
revendeur ou visitez www.harmanstoves.com
NOTE
Model(s):P35i-C Pellet Insert
NOTICE: SAVE THESE INSTRUCTIONS
Please read this entire manual before installation and use of
this pellet fuel-burning room heater. Failure to follow these
instructions could result in property damage, bodily injury or even
death.
• Donotstoreorusegasolineorotherflammablevaporsand liquids in
the vicinity of this or any other appliance.
•
Donotoverfire-Ifanyexternalpartstartstoglow,youareoverfiring.Reduce
feedrate.Overfiringwillvoidyour warranty.
• Comply with all minimum clearances to combustibles
asspecified.Failuretocomplymaycausehousefire.
WARNING!
Hot glass will cause burns.• Do not touch glass until it is
cooled• NEVERallowchildrentotouchglass• Keep children away•
CAREFULLYSUPERVISEchildreninsameroomas
stove.• Alert children and adults to hazards of high
temperatures. High temperatures may ignite clothing or other
flammable materials.•
Keepclothing,furniture,draperiesandotherflammable
materials away.
HOT SURFACES!
Glass and other surfaces are hot during operation and cool
down.
WARNING!
Tested and approved for wood pellets only burning of any other
type of fuel voids your warranty. When burning higher ash content
pellets more frequent cleanings may be required.
CAUTION!
Check building codes prior to installation.•
InstallationMUSTcomplywithlocal,regional,stateand
national codes and regulations.•
Contactlocalbuildingorfireofficialsaboutrestrictions
and installation inspection requirements in your area.
CAUTION!
-
Harman® • P35i-C Installation Manual_R5 • 2019 -___ • 03/212
8390-784i
= Contains updated information
TABLE OF CONTENTS
Safety Alert Key:• DANGER!
Indicatesahazardoussituationwhich,ifnotavoidedwill result in death
or serious injury.•
WARNING!Indicatesahazardoussituationwhich,ifnotavoidedcould result
in death or serious injury.• CAUTION!
Indicatesahazardoussituationwhich,ifnotavoided,couldresultinminorormoderateinjury.•
NOTICE:Indicatespracticeswhichmaycausedamagetothestoveortoproperty.
InstallationStandardWorkChecklist . . . . . . . . . . . . . . .
. . . . . 3
1 Product Specific and Important Safety Information A.
ApplianceCertification . . . . . . . . . . . . . . . . . . . . . .
. . . . . . 4B. GlassSpecifications . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . 4C.MobileHomeApproved . . . . . . . . .
. . . . . . . . . . . . . . . . . . 4D.
BTU&EfficiencySpecifications . . . . . . . . . . . . . . . . .
. . . . 4E. Non-CombustibleMaterialsSpecification. . . . . . . . .
. . . . . 5F. CombustibleMaterialsSpecification . . . . . . . . . .
. . . . . . . 5G. Electrical Codes . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . 5H.California . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
2 Getting Started A. DesignandInstallationConsiderations . . . .
. . . . . . . . . . . 6B. ToolsandSuppliesNeeded . . . . . . . . .
. . . . . . . . . . . . . . . 7C. InspectApplianceandComponents . .
. . . . . . . . . . . . . . . . 7
3 Clearances A. Appliance Dimension Diagram . . . . . . . . . .
. . . . . . . . . . . . 8B.
ClearancestoCombustibles&FloorProtection. . . . . . . . .
9C.MinimumOpening-Masonry&ManufacturedFireplaces . 9
4 Termination Location and Vent InformationA. Vent Termination
Design . . . . . . . . . . . . . . . . . . . . . . . . . 10B.
Venting&UseofElbows . . . . . . . . . . . . . . . . . . . . . .
. . . 14C. BatteryBack-upPower. . . . . . . . . . . . . . . . . . .
. . . . . . . . 15D.OutsideAir . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . 16E.
LocatingYourApplianceandChimney . . . . . . . . . . . . . . . 16F.
Negative Pressure . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . 17G.AvoidingSmoke&Odors . . . . . . . . . . . . . . .
. . . . . . . . . . 17H.MobileHomeInstallation . . . . . . . . . .
. . . . . . . . . . . . . . . 19I. FireSafety . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . 20J.
InspectAppliance&Components . . . . . . . . . . . . . . . . . .
20
5 Appliance Setup A. UnpackingUnit . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . 21B. ControlBoardInstallation .
. . . . . . . . . . . . . . . . . . . . . . . . 22C.
SecuringMountingFrame . . . . . . . . . . . . . . . . . . . . . . .
. 22D.RoutingthePowerCord . . . . . . . . . . . . . . . . . . . . .
. . . . . 22E. InstallingtheVenting . . . . . . . . . . . . . . . .
. . . . . . . . . . . . 23F. InstallingtheBodyintotheMountingFrame
. . . . . . . . . . 23G.RoomSensorInstallation . . . . . . . . . .
. . . . . . . . . . . . . . . 23H. FlameGuideExtension . . . . . .
. . . . . . . . . . . . . . . . . . . . 24I.
FireboxDraftandCombustionFanRPM . . . . . . . . . . . . . 25
6 Reference Materials A. SafetyReminders . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . 26B. Wiring Diagram . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
!
-
Harman® • P35i-C Installation Manual_R5 • 2019 -___ • 03/213
8390-784i
Installation Standard Work Checklist
ATTENTION INSTALLER:Follow this Standard Work Checklist
This standard work checklist is to be used by the installer in
conjunction with, not instead of, the instructions contained in
this installation manual.Customer: ________________________________
Date Installed: __________________________Lot/Address:
________________________________ Location of Stove:
__________________________ ________________________________
Installer: __________________________ Model:
________________________________ Dealer/Distributer Ph #
__________________________ Serial Number:
__________________________
! WARNING! Risk of Fire or Explosion! Failure to install
appliance to these instructions can lead to a fire or
explosion.Appliance Install Section 3 YES IF NO, WHY?Required
non-combustible floor protection
________________________________Verified clearances to combustible.
________________________________Unit is Leveled and secured.
________________________________
Venting/Chimney Section 4Venting Configuration complies to vent
diagrams. ________________________________Venting installed, sealed
and secured in place with proper clearances.
________________________________Exterior wall/roof flashing
installed and sealed ________________________________Terminations
installed and sealed. ________________________________
Electrical Section 1120 VAC unswitched power provided to the
appliance. ________________________________Check outlet with
multi-meter for proper voltage. (115-120 VAC)
________________________________ Record voltage reading:
___________
Appliance Setup Section 5All packaging and protective materials
are removed ________________________________Accessories installed
properly ________________________________Manual bag and all it’s
contents are removed from inside the appliance and given to party
responsible for use and operation
________________________________Started appliance and verified that
all motors and blowers operate as they should.
________________________________Checked draft using a Manometer.
Record readings: __________ ________________________________
Hearth and Home Technologies recommends the
following:Photographing the installation and copying this checklist
for your file.This checklist remain visible at all times on the
appliance until the installation is complete.
Comments: Further description of the issues, who is responsible
(Installer/Builder/Other Trades, etc.) and corrective action needed
____________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________Comments
communicated to party responsible____________________ by
________________________ on __________ (Builder / Gen Contractor)
(Installer) (Date)
04/17
-
Harman® • P35i-C Installation Manual_R5 • 2019 -___ • 03/214
8390-784i
A. Appliance Certification
B. Glass SpecificationsThis appliance is equipped with 5mm
ceramic glass.
Replaceglassonlywith5mmceramicglass.Pleasecontactyour dealer for
replacement glass.
C. Mobile Home ApprovedThis appliance is approved for mobile
home installations when not installed in a sleeping room and when
an outside combustion air inlet is provided. The appliance must be
properly grounded to the frame of the mobile home using a minimum
of 8 AWG copper solid or stranded, insulated or bare wire or
equivalent and use only
listedpelletvent,Class“PL”connectorpipe.AHarman®OutsideAirKitmust
be installed in amobilehome installation.
NOTE: This installation must conform with local codes.
IntheabsenceoflocalcodesyoumustcomplywiththeASTME1509-12,ULC-S628-93&
(UM) 84-HUD
MODEL: P35i-CPelletInsertLABORATORY:
OMNI-TestLaboratories,Inc.,PFS-TECOREPORT NO.
135-S-25-6.2,0135PN025S,F19-531TYPE:
PelletFueledInsert/Supplementary
ForResidentialUseSTANDARD(s):
ASTME1509-12(2017),ULC-S628-00,
ASTME2515-11,ASTME2779-10
D. BTU & Efficiency Specifications
1 1 Product Specific and Important Safety Information
The P35i-C Pellet Insert is certified tocomply with 2020 EPA
particulate emission standards.
*Weighted average LHV efficiency using data collectedduring EPA
emissions test.**Weighted average HHV efficiency using data
collectedduring EPA emissions
test.***ArangeofBTUoutputsbasedonEPADefaultEfficiencyand the burn
rates from the low and high EPA
tests.****Basedonthemaximumfeedrateperhourmultipliedbyapproximately8600BTU’swhichistheaverageBTU’sfroma
pound of
pellets.Thiswoodheaterhasamanufacturer-setminimumlowburnratethatmustnotbealtered.Itisagainstfederalregulationsto
alter this setting or otherwise operate this wood heater in a
manner inconsistent with operating instructions in this manual.This
wood heater needs periodic inspection and repair for
properoperation.Itisagainstfederalregulationstooperatethis wood
heater in a manner inconsistent with operating instructions in this
manual.
EPA Certification Number: 245-19EPA Certified Emissions:
1.5g/hr*LHV Tested Efficiency: 74.2%**HHV Tested Efficiency:
68.2%***EPA BTU Output: 9,600-28,800****BTU Input 12,800-38,400Vent
Size: 4InchHopper Capacity: 62 lbsFuel Wood Pellet
Note: This installation must conform with local codes.
IntheabsenceoflocalcodesyoumustcomplywiththeASTM E 1509-2012, ULC
S628-93, (UM) 84-HUD
Note: Hearth&HomeTechnologies,manufacturerofthisappliance,
reserves the right to alter its products, their
specificationsand/orpricewithoutnotice.
Harman® is a registered trademark of Hearth &
HomeTechnologies.
Note: Somegeneratororbatteryback-upsystemsmaynotbecompatiblewith
themicro-processorelectronicson this appliance. Please consult the
power supply manufacturer for compatible systems.
THE STRUCTURAL INTEGRITY OF THE MANUFACTURED HOME FLOOR, WALL,
AND
CEILING/ROOF MUST BE MAINTAINED.
DO NOT INSTALL IN SLEEPING ROOM.
CAUTION!
-
Harman® • P35i-C Installation Manual_R5 • 2019 -___ • 03/215
8390-784i
E. Non-Combustible Materials
SpecificationMaterialwhichwillnotigniteandburn.Suchmaterialsarethose
consisting entirely of steel, iron, brick, tile, concrete, slate,
glass or plasters, or any combination thereof.Materials that are
reported as passing ASTM E 136, Standard Test Method for Behavior
of Materials in a Vertical Tube Furnace at 750º C and UL763 shall
be considerednon-combustiblematerials.
F. Combustible Materials SpecificationMaterials made of or
surfaced with wood,
compressedpaper,plantfibers,plastics,orothermaterialthatcanigniteand
burn, whether flame proofed or not, or plastered orunplastered
shall be considered combustible materials.
G. Electrical Codes120VAC,60Hz,Start5.0Amps,Run4.0AmpsNote: Some
generator or battery back-up systems may not be compatible with the
micro-processor electronics on this appliance. Please consult the
power supply manufacturer for compatible systems.WARNING! Risk of
Fire! Hearth & Home Technologies disclaims any responsibility
for, and the warranty and agency listing will be voided by the
below actions.DO NOT:• Install or operate damaged appliance• Modify
appliance• Install other than as instructed by Hearth &
Home
Technologies• Operate the appliance without fully assembling
all
components• Overfire• Install any component not approved by
Hearth & Home
Technologies• Install parts or components not Listed or
approved.• Disable safety switchesImproper installation,
adjustment, alteration, service or maintenance can cause injury or
property damage.
Forassistanceoradditionalinformation,consultaqualifiedinstaller,
service agency or your dealer.
NOTE: Hearth&HomeTechnologies,manufacturer ofthis appliance,
reserves the right to alter its products, their
specificationsand/orpricewithoutnotice.
Harman® is a registered trademark of Hearth &
HomeTechnologies.
! WARNINGThis product and the fuels used to operate this product
(wood),andtheproductsofcombustionofsuchfuels,canexpose you to
chemicals including carbon
black,whichisknowntotheStateofCaliforniatocausecancer,andcarbonmonoxide,whichisknowtotheStateofCaliforniato
cause birth defects or other reproductive harm. For more
information go to: www.P65Warnings.ca.gov
H. California
-
Harman® • P35i-C Installation Manual_R5 • 2019 -___ • 03/216
8390-784i
A. Design and Installation Considerations1. Appliance
LocationNOTICE: Check building codes prior to installation.•
InstallationMUSTcomplywithlocal,regional,stateand
national codes and regulations.• Consult insurance carrier,
local building inspector, fire
officialsorauthoritieshavingjurisdictionoverrestrictions,installation
inspection and permits.
Itisagoodideatoplanyourinstallationonpaper,usingexactmeasurements
forclearancesandfloorprotection,beforeactually beginning the
installationConsideration must be given to:•
Safety,convenience,trafficflow• Placement of the chimney and
chimney connector. • If you are not using an existing chimney,
place the
appliance where there will be a clear passage for a
factory-builtlistedchimneythroughtheceilingandroof.
• Installing an optional outside air kit would affect
thelocation of the vent termination.
Suitable fireplaces for installation:• MasonryFireplace•
ExistingFactoryBuiltWoodBurningFireplace•
Harman®ZeroClearanceCabinet-Part#1-00-574323EXCEPTION:Masonryorsteel,includingthedamperplate,may
be removed from the smoke shelf and adjacent damper frame if
necessary to accommodate a chimney liner,
Marginal Location:• Below peak
Location NOT recommended:• Not the highest point of the roof•
Wind loading possible
Multi-level Roofs
Windward
Leeward
Recommended:Outside Air Intakeon windward side
NOT recommended:Outside Air Intakeon leeward side
Recommended Location:• Above peak
Recommended:• Insulated exterior chase
in cooler climates
Recommended Location:• Above peak• Inside heated space
Location NOT recommended:• Too close to tree• Below adjacent
structure• Lower roof line• Avoid outside wall
Marginal Location:• Wind loading possible
Figure 2.1
2 2 Getting Started provided that their removal will not weaken
the structure of the fireplace and chimney, andwill not reduce
protectionfor combustible materials to less than that required by
the National Building
Code.Sincepelletexhaustcancontainash,sootorsparks,youmust consider
the location of:• Windows• AirIntakes• Air Conditioner•
Overhangs,soffits,porchroofs,adjacentwalls•
Landscaping,vegetationWhen locating vent and venting termination,
vent above roof line when possible.Warning! Risk of Fire Damaged
parts could impair safe operation. Do NOT install damaged,
incomplete or substitute components.NOTICE: Locating the appliance
in a location of considerable air movement can cause intermittent
smoke spillage from appliance. Do not locate appliance near:•
Frequently open doors• Central heat outlets or returns
Installation and service of thisappliance should be performed by
qualifiedpersonnel.Hearth&HomeTechnologies recommends
HHTFactory Trained or NFI Certifiedprofessionals.
-
Harman® • P35i-C Installation Manual_R5 • 2019 -___ • 03/217
8390-784i
ReciprocatingSawHammerPhillipsScrewdriverTapeMeasureLevelNon-CombustibleSealantMaterial
GlovesSafetyGlassesElectricDrill&Bits
May also need:VentSupportStrapsVenting Paint
Tools and building supplies normally required for installation,
unless installing into an existing masonry fireplace:
B. Tools And Supplies Needed
C. Inspect Appliance and Components• Carefully remove the
appliance and components from the
packaging. • The vent system components and decorative doors
and
fronts may be shipped in separate packages. •
Ifoptionallogsetispurchased,thelogbracketmustbe
installed prior to installing the log set.• Report
toyourdealeranypartsdamaged inshipment,
particularly the condition of the glass. • Read all of the
instructions before starting the
installation. Follow these instructions carefully during the
installation to ensure maximum safety and benefit.
Hearth&HomeTechnologiesdisclaimsanyresponsibilityfor, and
the warranty will be voided by, the following actions:•
Installationanduseofanydamagedapplianceorvent
system component.• Modificationoftheapplianceorventsystem.•
InstallationotherthanasinstructedbyHearth&Home
Technologies.• Installation and/or use of any component part
not
approvedbyHearth&HomeTechnologies.Any such action may cause
a fire hazard.
Risk of Fire, Explosion or Electric Shock! DO NOT use this
appliance if any part has been under water. Call a qualified
service technician to inspect the appliance and to replace any part
of the control system that has been under water.
WARNING!
WARNING!RISK OF FIRE OR EXPLOSION! Damaged parts could impair
safe operation. DO NOT install damaged, incomplete or substitute
components. Keep appliance dry.
-
Harman® • P35i-C Installation Manual_R5 • 2019 -___ • 03/218
8390-784i
3 3 Clearances A. Appliance Dimension
DiagramDimensionsareactualappliancedimensions.Useforreferenceonly.
Figure 3.1
14”
356m
m
22”559mm
8”20
3mm
10”
254m
m
2”50mm
Standard Surround#1-00-774221
Oversized Surround#1-00-774250
A 40"(1016mm) 46"(1168mm)B 31"(787mm) 34"(864mm)
24”610mm
A
B
23-3
/4”
603m
m
19-1
/2” (
495m
m)
Hop
per
23-1
/2” (
597m
m)
Hop
per
9-1/4” (235mm)Glass
-
Harman® • P35i-C Installation Manual_R5 • 2019 -___ • 03/219
8390-784i
When selecting a location for the appliance it is important to
considertherequiredclearancestowalls(seeFigure3.2).WARNING! Risk of
Fire or Burns! Provide adequate clearance around air openings and
for service access. Due to high temperatures, the appliance should
be located out of trafficandawayfromfurnitureanddraperies.
NOTICE:
IllustrationsreflecttypicalinstallationsandareFORDESIGNPURPOSESONLY.Illustrations/diagramsarenotdrawn
to scale. Actual installation may vary due to individual design
preference.
B. Clearances to Combustibles & Floor Protection
*Floorprotectionmustbeusedfromhearthopeningto6"(152mm)infrontofdoorglassand6"(152mm)toeachsideofthestovebodyOR8”(203mm)tosidestoprotectcombustiblesfromhotashes.Aminimumsizewillbe8-7/8"deepby24-5/8"wideandbemadeofanon-combustiblematerialormeetULapproval.
Figure 3.2
G H
F
Location Inches MillimetersF MinimumWidth 24 609G MinimumDepth
14-1/2 368H MinimumHeight#1-70-774235 23-1/2 597H
MinimumHeight#1-70-774195 19-1/2 495
C. Minimum Opening - Masonry and Manufactured Fireplaces
Mantel
Side
Wall
Face Trim
A
B
C
E
D
F
Location Inches MillimetersA Inserttocombustiblesidewall 13 330B
Surroundtoptofacetrim 0 0C Surroundsidetofacetrim 1 25D
Inserttopto(max)12"mantel 12 305E Door opening to front 6 152F Door
opening to side 6 152
-
Harman® • P35i-C Installation Manual_R5 • 2019 -___ • 03/2110
8390-784i
4 4 Termination Location and Vent Information A. Venting
Termination Design #1 Installing into an existing fireplace
chimney
Thismethodprovidesexcellentventingwith100%outsideairwhichisthemostefficientoperationofthisunit.Thismethodalso
provides natural draft in the event of a power failure.
A4”stainlesssteelflexpipeisneededforthefluepipe,and3"aluminumorStainlessSteelFlexPipeisusedfortheintake.
CHIMNEY CONNECTOR PIPE MAY NOT PASS THROUGH CONCEALED SPACES
INCLUDING AN ATTIC, ROOF SPACE, CLOSET, FLOOR OR CEILING.
Heightofexistinghearth
#2 Installing into an existing fireplace
chimneyThismethodprovidesexcellentventingfornormaloperation.This
method also provides natural draft in the event of a power failure.
A cap should be installed on the chimney to keep out rain.
Combustion air is provided from the living area and enters the feed
system from around the wing and stove body spaces.
The chimney top must be capped to prevent rain and/or snow
fromenteringthe chimney.See Figure 4.8, for information on
theoptionalHarman®AdjustableStainlessSteelIntakeExtension.
The damper area must be sealed with a non-combustible material
and it isrecommended that Kaowoll, mineral wool, or an equivalent
non-combustibleinsulation be placed on top of the sealed area to
reduce the possibility of condensation. Insulation alone shouldnot
be used to seal the damper opening. For quick and easy
installation, purchase thesteelHarmanBlockOffPlate,1-00-25625.
The chimney top must be capped to prevent rain and/or snow
fromenteringthe chimney.
The damper area must be sealed with a non-combustible material
and it isrecommended that Kaowoll, mineral wool, or an equivalent
non-combustibleinsulation be placed on top of the sealed area to
reduce the possibility of condensation. Insulation alone shouldnot
be used to seal the damper opening. For quick and easy
installation, purchase the steelHarmanBlockOffPlate,
1-00-25625.
Figure 4.1
Figure 4.2
DO NOT REMOVE BRICKS OR MORTAR FROM THE EXISTING FIREPLACE.
DO NOT REMOVE BRICKS OR MORTAR FROM THE EXISTING FIREPLACE.
WARNING!
WARNING!
WARNING!
-
Harman® • P35i-C Installation Manual_R5 • 2019 -___ • 03/2111
8390-784i
36”
12” min.
12” Min.
#3 Installing into an existing
chimneyThismethodprovidesexcellentventingfornormaloperation.This
method also provides natural draft in the event of a
powerfailure.Ifthechimneyconditionisquestionableyoumaywanttoinstallalinerasinmethod#2.
This is the minimum allowed vent pipe using 4" stainless
steelflexpipe.
Theventpipemustextendpastthedampersealingareabyat least 12
inches.
Note:Theinsulationmaterialmustnotbeallowedtoexpandtothepointthatitcoverstheendoftheflexpipe.
The chimney should be capped with any style cap that will not
allow rain or snow to
enter.InsomeplacesintheUSandCanada,itisrequiredthattheventpipeextendallthewaytothetopofthechimney.Checkyour
local codes.
The chimney top must be capped to
preventrainand/orsnowfromenteringthe chimney.
The damper area must be sealed withanon-combustiblematerialandit
is recommended that Kaowoll, mineral wool, or an equivalent
non-combustible insulation be placed on top of the sealed area to
reduce the possibilityofcondensation.Insulationalone should not be
used to seal the damper opening. For quick and easy installation,
purchase the steel HarmanBlockOffPlate,1-00-25625.
#4 Preferred
methodThismethodprovidesexcellentventingfornormaloperationandinafireplacewithinadequatefluespace,oraheightofover30feet.4"PLventpipeshouldbeusedwiththeneededswivelfluestub.
Note: With a 100% outside air kit the outside air can be
installedinthesamemannerasthefluepipe.
KEEP COMBUSTIBLES (SUCH AS GRASS, LEAVES, ETC.) AT LEAST 3 FEET
AWAY FROM THE FLUE OUTLET ON THE OUTSIDE OF THE BUILDING.
Stainless Steel Outside Air Inlet Cover Part# 1-10-09542
12" min.
Chimney top MUST BE SEALED
Fiberglass insulation packed above the damper opening and sealed
plate. (Not aHarman®product.)
CHIMNEY CONNECTOR PIPE MAY NOT PASS THROUGH CONCEALED SPACES
INCLUDING AN ATTIC, ROOF SPACE, CLOSET, FLOOR OR CEILING.
Figure 4.3
Figure 4.4
DO NOT REMOVE BRICKS OR MORTAR FROM THE EXISTING FIREPLACES.
WARNING!
WARNING!
CAUTION!
-
Harman® • P35i-C Installation Manual_R5 • 2019 -___ • 03/2112
8390-784i
Installing the P35i-C Pellet Insert into an existing factory
built wood burning fireplaceWhen installing the P35i-C Pellet
Insert into a factorybuiltwoodburning fireplace,
theManufacturedFireplaceInstallationKit #1-00-574205must be used.
In addition,several things need to be taken into
consideration.Thesizeof thefireplaceopening.Will theunitfit into
theopening?Manyof theseunits havemetal smoke
shieldsinsidethetopthatcanberemovedtogainheight.Oftentheside and
rear refractory can be removed to gain depth and
width.Insomecircumstances,thefrontlowerliporgrillworkmay also be
removed. Be sure and follow the guidelines in the kit instructions.
Floor protection guidelines, as listed on Figure 3.2 must also be
followed. Thefactorybuiltchimneymustbe listedperUL127(US)andmeet
typeHTrequirementsofUL103(US).
FactoryBuiltfireplacechimneystestedtoUL127-98maybe,atthefireplacemanufacturersoption,testedtothesamecriteriaasUL103HTrequirements.IfthechimneyisnotlistedasmeetingHTrequirements,orifthefactorybuiltfireplacewastested
prior to 1998, a full height listed chimney liner must be
installedfromtheappliancefluecollartothechimneytop.Linermustmeet
high temperature (2100°F)
perUL1777(US).Thelinermustbesecurelyattachedtoboththefluecollar and
the chimney cap. To prevent room air passage to thechimneycavityof
thefireplace,seal
thedamperareaaroundthechimneylinerwithfiberglassbatting.
Note: If the Harman® P35i-C Pellet Insert is installed into a
factory built wood burning fireplace, this label (Harman® part
#3-90-674204) MUST be attached to the altered fireplace. This label
is included in the Manufactured fireplace installation kit.
THISFIREPLACEHASBEENALTEREDTOACCOMMODATEAFIREPLACEINSERTANDSHOULDBEINSPECTEDBYAQUALIFIEDPERSONPRIORTOREUSEASACONVENTIONALFIREPLACE
Figure 4.5
OPTIONAL HOPPER CONFIGURATIONS FOR SMALLER FIREPLACE
OPENINGS:TheHarman®P35i-CPelletInsertcanbefactorybuiltwithshorterhopperconfigurations.Thestandardrequiresa23-1/2"opening.Part#1-70-774235Option1:Requiresa19-1/2"openingheight.Part#1-70-774195Keep
in mind the hopper capacities will decrease with the optional
heights.
19.5
"23.5
"
IN CANADA:This fireplace insertmust be installedwith a
continuouschimney liner of a minimum 4" diameter extending from the
insert tothe top of the chimney. The chimney liner must conform to
the Class 3
requirementsofCAN/ULC-S635,StandardforLiningSystemsforExistingMasonry
or Factory Built Chimneys and Vents, or
CAN/ULC-S640,StandardforLiningSystemsforNewMasonryChimneys.
Additionally, the firebox floor of the Zero Clearance Wood
Fireplace may be removed down to the outer metal shell of the
fireplace if kit 1-00-574305 is used. The kit includes installation
instructions and all materials needed to remove the firebox floor
and still maintain a safe, compliant installation. Be certain to
contact local code enforcement officials before beginning any
modifications, as they may not be reversible in many cases.
-
Harman® • P35i-C Installation Manual_R5 • 2019 -___ • 03/2113
8390-784i
Installing the P35i-C Pellet Insert into a Harman Zero Clearance
CabinetIfyoudon’thaveafactorybuiltfireplaceormasonryfireplace,theP35i-CPelletInsertcanalsobeinstalledintotheHarmanZeroClearanceCabinet,Part#1-00-774235.Thisistheonly
permissiblewaytoinstalltheP35i-CPelletInsertwithoutasuitablefireplace.AftertheHarmanZeroClearanceCabinetisinstalled,typePLventpipe,wallpass-throughsandterminationsareused(Note:Flexpipeisnotapprovedthesetypesofinstallation).DetailedinstallationinstructionsareincludedwiththeZeroClearanceCabinet.Thesesameinstallationinstructionscanalsobefoundon-lineatwww.harmanstoves.com.BelowaretwosampleinstallationsusingtheHarmanZeroClearanceCabinet.
PLVentPipeinstalledthroughaceiling.
PLVentPipeinstalledthroughanexteriorwall
HarmanZeroClearanceCabinet
Requirements for Terminating the Venting through an Exterior
Wall.The clearance to a window or door that may be opened must
beaminimumof48"tothesideand48"belowthewindow/door, and 12" above
thewindow/door. (with outside air installed, 12” to the side or
below)
-
Harman® • P35i-C Installation Manual_R5 • 2019 -___ • 03/2114
8390-784i
A combustion blower is used to extract the
combustiongasesfromthefirebox.Thiscausesanegativepressureinthefireboxandapositivepressure
in theventingsystemas shown in Figure 4.6. The longer the vent pipe
and more elbowsusedinthesystem,thegreatertheflowresistance.The
recommended maximum flue lengths for the P35i-C Pellet Insert are
as follows:4" Flex
Pipe:Maximum30Ft.VerticalLongrunsofflexorPLventpipeinstalleddirectlyverticalfromthefluestubmayrequiremorefrequentcleaningduetoflyashfallingoffinsideandcollectingdirectlyabovethecombustion
blower outlet.Any use of horizontal venting will require more
frequent
cleaning.Itistheresponsibilityoftheinstallertomakesuretheentireflueconfigurationisaccessibleforcleaning.4"
stainless steel flex vent piping is only allowed for
useinmasonryfireplacesandchimneysor
factorybuiltwoodburningfireplaceswithclassAmetalchimneys.Allpelletventpipe
must be secured together either by means provided by pipe
manufacturer or by 3 screws at each
joint.Note:Theunitshipswitha4”startercollar
forusingwithflexpipe.IftheunitwillbeinstalledwithTypePLpelletpipe,1-00-574100Stubkitwillneedtobeused.
Use only the specified venting components. Use of any other
components will void the product warranty and may pose a hazard.DO
NOT INSTALL A FLUE DAMPER IN THE EXHAUST VENTING SYSTEM OF THIS
APPLIANCE.DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE SERVING
ANOTHER APPLIANCE.INSTALL VENT AT CLEARANCES SPECIFIED BY THE VENT
MANUFACTURER.
B. Venting & Use of Elbows
+ = Positive static pressure= Negative static pressure
Insidehopper
Insidefirebox
Influepipe
Infanchamber&startercollar
+
+ -
-
-
Figure 4.6
-
Harman® • P35i-C Installation Manual_R5 • 2019 -___ • 03/2115
8390-784i
Harman® strongly recommends installing battery back-up to
minimize entry of smoke into the room in the event of power
loss.Your pellet/biomass burning appliance relies on
acombustionblowertoremoveexhaust.Apowerfailurewillcause the
combustion blower to stop. This may lead to
exhaustseepingintotheroom.Verticalriseintheventingmay provide
natural draft. It is, however, no guaranteeagainst leakage.There
are two Harman® approved battery back-up options for your
appliance:Uninterruptible Power Supply (UPS) UPS battery back-ups
are available online or at computer and
officeequipmentstores.YourHarman®appliancewithRevEorlater software
available beginning in November 2010 may
bepluggeddirectlyintoaHarman®approvedUPS:•
TheAPC(AmericanPowerConversion)model#BE750G
and the TrippLite model INTERNET750U are testedand approved.
Other brands or models may not becompatible.
Whenpowerislost,afullychargedUPSwillpowerasafe,combustion blower
only shut-down. Your appliance
willpulsetheblowereveryfewsecondstoclearexhaustuntilthefireisout.Note:
The UPS provides safe shut-down only. It is not intended for
continued operation.
Yourappliancewillrecognizewhenpowerisrestored.Whathappens
depends onESP temperature andwhether it isequipped with automatic
ignition:• In “Automatic” setting, units equipped with
automatic
ignitionwillrespondtothesetpointandESPtemperatureand resume
normal operation.
• In “Manual” setting or for units without automatic
ignition:
• IftheESPiscool,theappliancewillremainshutdown.•
IfthefireisoutandtheESPisstillwarm,thefeedermay
restart.Sincethefireisout,theESPtemperaturewillnotrise.Theunitwillthenshut-down,andmayflashasix-blinkstatuserror.(SeeESPerrorcodes)
• Ifthefireisstillburning,itwillresumenormaloperation.Contact
your dealer if you have questions about UPScompatibility with your
appliance.
CAUTION!Always keep appliance doors and hopper lid closed and
latched during operation and during power failures to minimize risk
of smoke or burn-back.
CAUTION!Use only Harman® approved battery back-up devices. Other
products may not operate properly, can create unsafe conditions or
damage your appliance.
C. Battery Back-up PowerMinimizing Smoke During Loss of Power
Using Battery Back-up
-
Harman® • P35i-C Installation Manual_R5 • 2019 -___ • 03/2116
8390-784i
Stub Mounting Bolts
Intake Stub
Stub Gasket
Self-drilling screws (2)
Outside Air Intake Weldment
D. Outside
AirTheoutsideairkitconsistsofaIntakeStub,StubGasket,OutsideAirintakeWeldmentandhardware.Figure4.7.Anadjustablechimneyintakeextension,part#1-00-674104is
available to be used on masonry chimneys only. Figure
4.8.Additional information and diagrams can be found under the
“Venting
TerminationDesign”sectionofthemanual.Toinstalloutsideair,usekitpart#1-00-774280.Followtheinstallation
instructions provided with the kit.
100%OutsideAirKit-#1-00-774280
Figure 4.7
E. Locating Your Appliance &
ChimneyLocationoftheapplianceandchimneywillaffectperformance.•
Installthroughthewarmairspaceenclosedbythebuilding
envelope. This helps to produce more draft, especially
duringlightinganddie-downofthefire.
• Penetrate the highest part of the roof. This minimizes the
effectsofwindloading.
• Locate termination cap away from trees, adjacentstructures,
uneven roof lines and other obstructions.
• Minimizetheuseofchimneyoffsets.•
Considertheappliancelocationrelativetofloorandceiling
and attic joists.
Chimney cap and flex termination with flashing plate (by
installer) THIS CAP MUST BE Stainless Steel
With the intake assenbly anchored into place, finish the 4” SS
flex liner and cap (by installer) by screwing the cap’s flashing
plate to the top of the intake assenbly.A waterproofing sealant can
be used to seal the corners and irregularities in the top of the
masonry chimney.
After adjusting the intake assembly for the flue size, secure
the assembly to the top of the chimney with some form of anchors or
screws.
Masonry Flue Liner
Masonry Chimney
AdjustableChimneyIntakeExtensionPart#1-00-674104
Figure 4.8
18 1/8”
18 1
/8”
18”
18”
22 1
/8”
18”
22 1/8”
4”
6”1”
Harman® SS Chimney Top Intake Assembly
•
DONOTCONNECTTHISUNITTOACHIMNEYFLUESERVICINGANOTHERAPPLIANCE.
• DONOTCONNECTTOANYAIRDISTRIBUTIONDUCTORSYSTEM.
Mayallowfluegasestoenterthehouse
CAUTION!
-
Harman® • P35i-C Installation Manual_R5 • 2019 -___ • 03/2117
8390-784i
F. Negative PressureWARNING! Risk of Asphyxiation! Negative
pressure can cause spillage of combustion fumes and soot. Negative
pressure results from the imbalance of air available
fortheappliancetooperateproperly.Itcanbestrongestinlower levels of
the house.Causes include:• Exhaustfans(kitchen,bath,etc.)•
Rangehoods• Combustion air requirements for furnaces, water
heaters
and other combustion appliances• Clothes dryers•
Locationofreturn-airventstofurnaceorairconditioning•
ImbalancesoftheHVACairhandlingsystem• Upperlevelairleakssuchas: -
Recessedlighting - Attichatch -
DuctleaksTominimizetheeffectsofnegativeairpressure:•
Installtheoutsideairkitwiththeintakefacingprevailing
winds during the heating season• Ensure adequate outdoor air for
all combustion appliances
andexhaustequipment• Ensure furnace and air conditioning return
vents are not
located in the immediate vicinity of the appliance• Avoid
installing the appliance near doors, walkways or
small isolated spaces•
Recessedlightingshouldbea“sealedcan”design• Attic hatches weather
stripped or sealed• Attic mounted duct work and air handler joints
and seams
taped or sealedNOTICE: Hearth & Home Technologies assumes no
responsibility for the improper performance of the chimney system
caused by:• Inadequate draft due to environmental conditions• Down
drafts• Tight sealing construction of the structure• Mechanical
exhausting devices
G. Avoiding Smoke and OdorsAvoiding Smoke and OdorsNegative
Pressure, Shut-down, and Power Failure:To reduce the probability of
back-drafting or burn-back in the pellet burning appliance during
power failure or shut-down conditions, the stove must be able to
draft naturally
withoutexhaustbloweroperation.Negativepressureinthehouse will
resist this natural draft if not accounted for in the pellet
appliance
installation.Heatrisesinthehouseandleaksoutatupperlevels.Thisairmustbereplacedwithcoldairfromoutdoors,whichflowsinto
lower levels of the house. Vents and chimneys into basements and
lower levels of the house can become the conduit for air supply,
and reverse under these conditions.Outside Air:Hearth & Home
Technologies recommend attaching outside air in all installations,
especially lower level and main floor locations.Per national
building codes, consideration must be given to combustion air
supply to all combustion appliances. Failure to supply adequate
combustion air for all appliance demands,
mayleadtoback-draftingofthoseandotherappliances.Whentheapplianceisside-wallvented:Theairintakeisbestlocatedonthesameexteriorwallastheexhaustventoutletandlocatedloweronthewallthantheexhaustventoutlet.When
the appliance is roof vented: The air intake is best
locatedontheexteriorwallorientedtowardstheprevailingwind direction
during the heating season.The outside air connection will supply
the demands of the pellet appliance, but consideration must be
given to the
totalhousedemand.Housedemandmayconsumesomeairneededforthestove,especiallyduringapowerfailure.Itmay
be necessary to add additional ventilation to the space in which
the pellet appliance is located. Consult with your local
HVACprofessionaltodeterminetheventilationdemandsforyour house.
-
Harman® • P35i-C Installation Manual_R5 • 2019 -___ • 03/2118
8390-784i
Vent Configurations:To reduce probability of reverse drafting
during shut-down conditions,Hearth&HomeTechnologies
stronglyrecommends:•
Installingthepelletventwithaminimumverticalrunof
fivefeet,preferablyterminatingabovetheroofline.•
Installingtheoutsideairintakeatleastfourfeetbelowthe
vent
termination.Topreventsootdamagetoexteriorwallsofthehouseandtopreventre-entryofsootorashintothehouse:•
Maintainspecifiedclearancestowindows,doors,andair
inlets, including air conditioners.•
Ventsshouldnotbeplacedbelowventilatedsoffits.Run
the vent above the roof.• Avoid venting into alcove locations.•
Vents should not terminate under overhangs, decks or
onto covered porches.• Maintainminimum clearance of 12 inches
from the
ventterminationtotheexteriorwall.Ifyouseedepositsdeveloping on
thewall, youmay need to extend thisdistance to accommodate your
installation conditions.
Hearth & Home Technologies assumes no responsibility for,
nor does the warranty extend to, smoke damage caused by reverse
drafting of pellet appliances under shut-down or power failure
conditions.WARNING! DO NOT CONNECT THIS UNIT TO ANY AIR
DISTRIBUTION DUCT OR
SYSTEM.Ifarearexitflueconfigurationisused,withorwithoutoutsideair,make
sure the flue pipe termination clearances arefollowed as per NFPA
211.Vent PipeBe sure to use approved pellet vent pipe wall and
ceiling pass- through fittings to go through combustible wallsand
ceilings. Be sure to use a starting collar to attach the venting
system to the stove. Follow venting manufacturer’s recommendations
for sealing pipe joints. 4” stainless steel flex vent piping is
only allowed for
useinmasonryfireplacesandchimneysorfactorybuiltwood-burningfireplaceswithclassAmetalchimneys.Pellet
venting pipe (also known as Type PL vent) isconstructed of two
layers with air space between the layers. This air space acts as an
insulator and reduces the outside surface temperature to allow a
clearance to combustibles of only 1 inch. The sections of pipe lock
together to form an air tight seal in most
cases.Wherepassingthroughanexteriorwallorroof,besuretousetheappropriatepass-throughdeviceprovidinganadequatevapor
barrier. Venting manufacturers generally provide these
pas-throughdevices.
Venting Termination Requirements1. Termination must exhaust
above air inlet elevation.
It is recommended that at least 60 inches (1524mm)of vertical
pipe be installed when appliance is vented directly through a wall.
This will create a natural draft, which will help prevent the
possibility of smoke or odor
ventingintothehomeduringapoweroutage.Itwillalsokeep exhaust from
causing a nuisance or hazard byexposing people or shrubs to high
temperatures. Thesafest and preferred venting method is to extend
thevent vertically through the roof.
2. Distance from doors and operable windows, gravity or
ventilation air inlets into building:a.
Notlessthan48inches(1219mm)below;b.
Notlessthan48inches(1219mm)horizontallyfrom;c.
Notlessthan12inches(305mm)above.
3. Distance from permanently closed windows:a.
Notlessthan12inches(305mm)below,horizontally
from or above.4. Distance between bottom of termination and
grade
should be 12 inches (305mm) minimum. This isconditional upon
plants in the area, and nature of grade
surface.Thegradesurfacemustbeanon-combustiblematerial(i.e.,rock,dirt).Thegradesurfacemustnotbelawn.
Distance between bottom of termination and public
walkwayshouldbe84inches(2134mm)minimum.
5. Distance to combustible materials must be 24 inches (610mm)
minimum. This includes adjacent buildings,fences, protruding parts
of the structure, roof overhang, plants and shrubs, etc.
6. TerminationCapLocation(HomeElectricalService)• Side-to-side
clearance is to be the same asminimum
clearance to vinyl inside corners.• Clearance of a termination
cap below electrical service
shallbethesameasminimumclearancetovinylsoffits.• Clearance of a
termination cap above electrical service
willbe12inches(305mm)minimum.• Location of the vent termination
must not obstruct or
interfere with access to the electrical service.For Canada Only:
This Fireplace Insert must be installed with a continuous chimney
liner of 4” diameter extending from the fireplace insert to the top
of the chimney. The chimney liner must conform to the Class 3
requirements of CAN/ULC-S635, Standard for Lining Systems for
Existing Masonry or Factory-Built Chimneys and Vents, or
CAN/ULC-S640, Standard for Lining Systems for New Masonry
Chimneys.
-
Harman® • P35i-C Installation Manual_R5 • 2019 -___ • 03/2119
8390-784i
H. Mobile Home
InstallationYoumustuseaHarman®OutsideAirKitforinstallationina
mobile home. 1. An outside air inlet must be provided for the
combustion
airandmust remainclearof leaves,debris, iceand/orsnow.
Itmustbeunrestrictedwhile theappliance is inuse to prevent room air
starvation which causes smoke
spillage.Smokespillagecanalsosetoffsmokealarms.
2. The combustion air duct system must be made of metal.
Itmustpermitzeroclearancetocombustibleconstructionand prevent
material from dropping into the inlet or into the area beneath the
dwelling and contain a rodent screen.
3. The appliance must be secured to the mobile home
structurebyboltingittothefloor(usinglagbolts).Usethesame holes that
secured the appliance to the shipping pallet.
4. Theappliancemustbegroundedwith#8solidcoppergrounding wire or
equivalent, terminated at each end with an NEC approved grounding
device.
5. Refer to “Clearances to Combustibles and FloorProtection”
section of this manual for listings tocombustibles.
6. Use silicone to create an effective vapor barrier atthe
location where the chimney or other component
penetratestotheexteriorofthestructure.
7. Follow the chimney manufacturer’s instructions when
installing the vent system for use in a mobile home.
8.
InstallationshallbeinaccordancewiththeManufacturersHome&SafetyStandard(HUD)CFR3280,Part24.
THE STRUCTURAL INTEGRITY OF
THEMOBILEHOMEFLOOR,WALLANDCEILING/ROOFMUSTBEMAINTAINED.DoNOTcutthrough:•
Floor joist, wall, studs ceiling trusses.•
Anysupportingmaterialthatwouldaffectthestructural
integrity.
SparkArrestorCap
RoofFlashing
ApprovedClass”L”or“PL”PelletVent
JoistShield/Firestop
StormCollar
Asphyxiation Risk:
NEVERINSTALLINTOASLEEPINGROOM
Consumesoxygenintheroom
WARNING!
Installation must comply with Manufactured Home and Safety
Standard (HUD), CFR 3280, Part 24
WARNING!
CAUTION!
Never draw outside combustion air from:
• Wall,floororceilingcavity.
• Enclosed space such as an attic or garage.
CAUTION!
-
Harman® • P35i-C Installation Manual_R5 • 2019 -___ • 03/2120
8390-784i
I. Fire SafetyToprovide reasonablefiresafety, the
followingshouldbegiven serious consideration:•
Installatleastonesmokedetectoroneachfloorofyour
home.• Locatesmokedetectorawayfromtheheatingappliance
and close to the sleeping areas. • Follow the smoke detector
manufacturer’s placement and
installation instructions and maintain regularly. •
ConvenientlylocateaClassAfireextinguishertocontend
withsmallfires.• Intheeventofahopperfire: • Evacuate the house
immediately.
• Notifyfiredepartment.
J. Inspect Appliance & Components• Remove appliance and
components from packaging
and inspect for damage.•
Reporttoyourdealeranypartsdamagedinshipment.• Read all the
instructions before starting the
installation. Follow these instructions carefully during the
installation to ensure maximum safety and benefit.
Inspect appliance and components fordamage. Damaged parts may
impair safe operation.
• DoNOTinstalldamagedcomponents.•
DoNOTinstallincompletecomponents.•
DoNOTinstallsubstitutecomponents.Reportdamagedpartstodealer.
WARNING!
• Installationanduseofanydamagedappliance.•
Modificationoftheappliance.•
InstallationotherthanasinstructedbyHearth&Home
Technologies.• Installation and/or useof any component part
notapprovedbyHearth&HomeTechnologies.
• Operating appliancewithout fully assembling allcomponents.
• DoNOTOverfire.Or any such action that may cause a fire
hazard.
FireRisk.Hearth&HomeTechnologies disclaimsany responsibility
for, and the warranty will be voided by, the following actions:
WARNING!
WARNING!THIS WOOD HEATER HAS A MANUFACTURER-SET MINIMUM LOW BURN
RATE THAT MUST NOT BE ALTERED. IT IS AGAINST FEDERAL REGULATIONS TO
ALTER THIS SETTING OR OTHERWISE OPERATE THIS WOOD HEATER IN A
MANNER INCONSISTENT WITH OPERATING INSTRUCTIONS IN THIS MANUAL.
-
Harman® • P35i-C Installation Manual_R5 • 2019 -___ • 03/2121
8390-784i
5 5 Appliance Set-Up A. Unpacking
UnitOncetheboxisremoved,theunitwillneedtoberemovefrom the
skid.Removetheashpancoverfromunittouncoverthespringlatches that
hold the unit to the mounting frame, Figure 5.1.
Figure 5.1-Removeashpancover.
Unlatch thespring latch locatedonboth therightand lefthand side
to release the unit from the mounting frame, Figure 5.2.
Figure 5.2-Unlatchspringlatch.
SpringLatch
Figure 5.3-Pullunitawayfromthemountingframe.
Once spring latches are unlatchedandpulled away
fromtheframe,firmlygrabthestoveandpullittowardyouandoutaway fromthe
frame.Setunit to theside,Figure5.3.Note: This may take 2 people to
achieve.
Now that the unit is removed you can now remove the
mountingframefromtheskid.Todothissimplyremove(4)5/16-18Hexheadbolts.Figure5.4.
Figure 5.4-Remove(4)5/16-18HexHeadBolts
(4)5/16-18HexHeadBolts
Now that the mounting frame is removed from the skid you can now
install the surround panels.
Note:Installationinstructionsforthesurroundarelocatedinsidetheboxwiththe
surround panels.
-
Harman® • P35i-C Installation Manual_R5 • 2019 -___ • 03/2122
8390-784i
B. Control Board
InstallationThecontrolboardispackagedinastaticresistantbag.Usecare
when handling, hold the control board only by the edges. Using
(4)#10sheetmetalscrews located in thehardwarepack, install the
control door hinge and control board assembly to the left side wing
surround, Figure 5.5.
R O U T E P O W E R C O R D AWAY F R O M T H E APPLIANCE. DO NOT
RUN THE CORD UNDER OR IN FRONT OF THE APPLIANCE.
WARNING!
D. Routing the Power CordWhen choosing an electrical supply
outlet, be sure the polarity is correct, and that the supplied
voltage is within the range of 117 to 123 Volts. Surge protection
is alsorecommended to protect the control board software in the
event of a surge or spike.
Oncetheoutletlocationisdecided,you'llneedtoinstallandroute the
power cord.Removethepowercordfromtheashpan.At the bottom of each of
the side surround panels is a knockout
forthecordretainer.Removetheappropriate knockout and feed the loose
wire end of the power cord into the hole. If your
cordneedstoexitfromtherightside,route the cord up the side and over
the top of the mounting frame andbackdowntheleftside.Usethe two
hooks on the top corners of the mounting frame to secure the cord.
Attach a star washer, the ground wire ring terminal, a second star
washer, the ring terminal from the ground wire
jumpertothebottomstudoftheleftsurroundpanel.Usinga pliers, compress
the cord clamp and push it into the hole.
Figure 5.5-Installcontrolboardassembly.
(4)#10sheetmetalScrews
Control door hinge
Control board assy.
C. Securing the Mounting FrameThe mounting frame is the anchor
for the appliance. If the frame is not secured properly, shifting
will occur when sliding the insert in or
out.Thestoveissuppliedwith(4)5/16-18HexHeadboltslocatedin the
hardware pack for leg levelers. These bolts should be threaded down
through the holes to raise the frame corners as needed to make the
frame level as needed, Figure 5.6.
Install thecouplernutweldments to the frame in
theholelocationthatsuitsyourneedswiththe(4)1/4-20x5/8flangescrewsandnuts
and1/2” jackbolts. Install themountingframe into the opening and
adjust these bolts to insure the frame is level, Figure 5.7.Note:
The use of all 4 leveling bolts may not be necessary.
Tightenthe1/2"jackboltsagainstthelintel.
LevelerBolts
Figure 5.6
1/2" threaded jackbolts with nuts
Coupler weldment and(4)1/4-20x5/8"Flangebolts
Tightenthe1/2"jackboltsagainstthelintelusingawrenchonthe1/2”nutssuppliedonthejackbolts.
Figure 5.7-Installjackbolts
-
Harman® • P35i-C Installation Manual_R5 • 2019 -___ • 03/2123
8390-784i
Connecting Wiring
HarnessInalargefireplaceopening,youmayhaveplentyofspacefor the
control board to remain attached. For a smaller fireplaceopening,
you'll likelyneed to remove thecontrolboard to route it through the
side of the mounting frame and out through the control
opening.Followthesesteps;• Feed theharnesswiresand theESPwire
through the
opening in the mounting frame and out through the control
opening in the surround panel.
• Holding the control board outside the opening in
thesurroundpanel,re-attachtheharnessplugandtheESPwire.
•
AfterdeterminingthelocationoftheRoomSensor(SeenextSection),Attachittothetwomalespadeterminalsnear
the top of the control board.
NOTE:Theseconnectionsarenotpolarityspecific.• From the power
cord, attach the green ground wire to the
grounding post located on the feeder air intake snout.• The
black wire from the power cord gets attached to the
short brown wire from the control harness• The white wire from
the power cord will attach to the
short white wire on the control harness.•
Installthecontrolpanelintothesurround;Rightsidefirst,
then tilt in the left side.• Secure using the four blackmachine
screws included
with the surround.
E. Installing the
VentingThefluecollarontherearofthemountingframeisdesignedtopivot.Loosenthefourmountingboltsandadjusttheangleof
the collar as needed, Figure 5.10.
Note:Wheninstalledinarearventconfiguration,themaximumBTU may be
reduced due to elevated ESP
temperaturesassociatedwiththehorizontalexhauststream.
Figure 5.10
Top Vent RearVent
F. Installing the Body into the Mounting FrameAttach the female
terminal of the ground jumper wire to the
groundtablocatednexttotheairintake,Figure5.11.
The rollers on either side of the insert body will ride on the
railsofthemountingframe.Oncethebodyisallthewayin,hook and close the
spring latches located on each side of the unit to secure the stove
body to frame, Figure 5.12.
Figure 5.11
Ground Terminal
Figure 5.12
Roller
Rail
SpringLatch
G. Room Sensor InstallationAlthough not required, it is
recommended that the room
sensorbeconnectedineveryinstallation.Usingaminimumsize 18 gauge
wire, you may splice in an additional length, to
extendtheroomsensor.Thefollowingaretypicallocationsfortheroomsensor;•
Onan interiorwallnext toor inplaceofa typicalwall
thermostat.• Onthelegofacoffeetableorendtableinyourfavorite
sitting location.•
Stickingoutthroughthepunchedholeatthelowerright
corner of the control
panel.Note:Wheninstallingtheroomsensorexternally,limitthedistance
from the stove to 25 feet or less.
-
Harman® • P35i-C Installation Manual_R5 • 2019 -___ • 03/2124
8390-784i
Figure 5.13
Roomsensorplacedheregivesanaccuratemeasureofreturnair.Pushthepre-cutholeinward,andfeedthesensorfromthebackside.Allowthebulbofthesensortoextendapproximately1-1/2"intotheroom.Useawiretieonthepush-intabtosecurethe
sensor wire.
H. Flame Guide Extension
OncetheflameguideisinstalledtheFlameGuideExtensionshouldbeinstalledbyslidingitinbehindtheflameguideasshownbelow.Notice
thebendpointsawayfromtheHeatExchanger.
Burn Pot
Cast Flame Guide
Steel Flame Guide Extension
Heat Exchanger
Bends away from heat Exchanger
Figure 5.14
Oncethelocationhasbeendecided,runthewiringtothecontrolpanel.You'llneedtoremovethetwoterminalsfromthe
end of the sensor cable and replace them with the two smaller
terminals from the hardware bag. Plug the terminals into the
control board. These connections are not polarity
specific.Note:Iftheroomsensorislocatedtooclosetotheappliance,or
inadirectpathof thedistributionair,Youmayneedtoelevate the
temperature setting to maintain a comfortable temperature level
throughout the heated space.See Section "E. Draft Test Procedure"
under Operating Instructions.
-
Harman® • P35i-C Installation Manual_R5 • 2019 -___ • 03/2125
8390-784i
Aftertheinstallationiscompleted,butbeforethefirstfireislit,checkandrecordthehighandlowdraft
readings.
Press the icon a second time, the combustion fan will go
to“Maximum”(assetintheAuthorized Dealer Only area
underthecombustionfanicon)The“Maximum”isfactorysetat2900RPM.AllowtheRPMtostabilizeandrecordthefireboxdraftMaximum.
BeforeInstall:__________IWC AfterInstall:__________IWC(Firebox
Draft and Combustion Fan RPM Cont.)Press the icon a third time, the
combustion fan will go to “Minimum” (as set in theAuthorized Dealer
Only area
underthecombustionfanicon)allowtheRPMtostabilizeandrecordthefireboxdraftminimum.
BeforeInstall:__________IWC AfterInstall:__________IWCCold Stove
Draft:2500RPM Low-.20and-.252900RPM
High-.45and-.50Leavingthetestscreenwillendanytestsinprogressandgoes
back to whatever mode of operation it was set to on the home
screen.Iftheunitisnotadjustedproperly,itdoesnotcauseasafetyconcern.Iftheunitisadjustedtoohigh,onlyefficiencyislost.Iftheunitisadjustedtoolow,thelowdraftpressureswitchwill
not allow the feed motor or the igniter to operate.
Figure 5.15
Silicone Draft Meter PortThe Draft Test Port can be accessed
behind the ash pan cover on the left hand side of the unit above
the spring latch.
•
DONOTCONNECTTHISUNITTOACHIMNEYFLUESERVICINGANOTHERAPPLIANCE.
• DONOTCONNECTTOANYAIRDISTRIBUTIONDUCTORSYSTEM.
Mayallowfluegasestoenterthehouse
CAUTION!
I. Firebox Draft and Combustion Fan
RPMTheseunitsarepre-testedatthefactorywithexactly120VAC,60Hz.Theyarecheckedandadjustedforfireboxtightness,gasket
leakage, motor operation and igniter operation. The
P35i-Cisthenfactorysetatamid-pointadjustmentandinmost cases will
not need any
adjustments.Checkandrecordthefireboxdraftbeforeinstallingventingand
after venting is installed (before starting fire).There is a
silicone draft meter port located behind the ash pan cover on the
left hand side of the unit above the spring
latch.Installthemagnahelicmeter(capable of at least .5” of water
column) Figure 5.15.Considerations for successful draft include:•
Negativepressureinthefirebox• LocationofapplianceandchimneyTo
measure the draft or negative pressure on your appliance use a
magnahelic or a digital pressure gauge capable of
reading0-1inchesofwatercolumn(W.C.). The appliance should be
running on high for at least 15 minutes for the test.With the stove
running on high you should have a negative pressure equal to or
greater than the number given in the
chartbelow.Ifyouhavealowerreadingthanyoufindonthechart, your
appliance does not have adequate draft to burn the fuel
properly.Plugunitintoa120VAC,60Hzoutlet.Gotothe“HomeScreen”,thepowericonshouldbegray.Pressmenu,onthefirstmenupress“test”.The
test screen has 4 component test modes. The second icon is for the
combustion fan test.Onepressoftheiconturnsthecombustionfantofull
linevoltage. (Note: During this test , the combustion fan will not
achieve its top RPM of 3200 due to the density of the ambient
air.)AllRPMdisplayscouldvary+/-50fromthatofthesetRPM’s.Allowseveralminutesforthefanmotortowarm
up.
MAGNEHELIC
INCHES OF WATER
0.10
.20 .30 .40.50
-
Harman® • P35i-C Installation Manual_R5 • 2019 -___ • 03/2126
8390-784i
6 6 Reference Material A. Safety
RemindersWheninstallingtheHarman®P35i-CPelletInsert,respectbasic
safety standards.Read these instructions carefullybefore youattempt
to install or operate
theP35i-CPelletInsert.Failuretodosomayresultindamagetopropertyorpersonal
injury and may void the product warranty.Consult with your local
building code agency and insurance representative before you begin
your installation to ensure compliance with local codes, including
the need for permits andfollow-upinspections.
MOBILE/MANUFACTURED HOME GUIDELINES DO NOT ALLOW INSTALLATION IN
A SLEEPING ROOM.
WARNING!
KEEP COMBUSTIBLE MATERIALS SUCH AS GRASS, LEAVES, ETC. AT LEAST
3 FEET AWAY FROM THE POINT DIRECTLY UNDER THE VENT TERMINATION.
WARNING!
USE OF IMPROPER FUELS, FIRE STARTERS OR ALTERING THE STOVE FOR
HIGHER HEAT OUTPUT MAY CAUSE DAMAGE TO THE STOVE AND COULD RESULT
IN A HOUSE FIRE. USE ONLY APPROVED FUELS AND OPERATION
GUIDELINES
WARNING!
THE STRUCTURAL INTEGRITY OF THE MOBILE HOME FLOOR, WALL, AND
CEILING/ROOF MUST BE MAINTAINED.
CAUTION!
THE STOVE IS HOT WHILE IN OPERATION.KEEP CHILDREN, CLOTHING AND
FURNITURE AWAY. CONTACT MAY CAUSE SKIN BURNS.
CAUTION!
DO NOT USE MAKESHIFT COMPONENTS OR OTHER COMPROMISES WHEN
INSTALLING THIS APPLIANCE.
CAUTION!
Due to high temperatures, this stove should be placed out of
trafficandawayfromfurnitureanddraperies.Children and adults should
be alerted to the hazards of high surface temperatures and should
stay away to avoid burn
toskinand/orclothing.Youngchildrenshouldbecarefullysupervisedwhentheyarein
the same room as the
stove.Clothingandotherflammablematerialsshouldnotbeplacedon or near
this stove.Installationand repair of this stove should bedoneby
aqualifiedserviceperson.Theapplianceshouldbeinspectedbeforeuseandatleastannuallybyaqualifiedserviceperson.More
frequent cleaningwill be required. It is imperativethat control
compartments, burners, and circulating air passageways of this
stove be kept clean.
CAUTION!This appliance must be vented to the outside.
-
Harman® • P35i-C Installation Manual_R5 • 2019 -___ • 03/2127
8390-784i
B. Wiring Diagram
4 865 11
1091 3
WHITE 11 PIN PLUG
PART # 3-90-94734 (REV C)
HARMAN ACCENTRA/P35i/P40i/P43/P61/P68/XXV/52i PELLET STOVE
WIRING DIAGRAM
CON
TRO
L BO
ARD
LT.BLUE
LT.B
LUE
WHITE
RO0M
SEN
SOR
PORT
BLACK
YELLOW
RED
10
BLAC
K11
BRO
WN
PLU
GG
ED
YELL
OW
EMPT
Y
DK
BLU
E
WH
ITE
WH
ITE
WH
ITE
WH
ITE
7 8 95 632 41
TWIS
TED
WIR
E
ESP
ESP
PRO
BE
IGN
ITER
ELE
MEN
T
WA
RNIN
G: R
OU
TE P
OW
ER C
ORD
AW
AY F
ROM
TH
E A
PPLI
AN
CE. D
O N
OT
RUN
TH
E CO
RD U
ND
ER O
R IN
FRO
NT
OF
THE
APP
LIA
NCE
.
ACC5
2i /
P35i
RO
OM
SEN
SOR
WIR
E FO
R EX
TERN
AL
LOCA
TIO
N
ROOM SENSOR TWISTED WIRES
18/3 CORD
18/3
PO
WER
CO
RD
GRE
EN W
IRE
IS G
ROU
ND
BON
DED
TO
STO
VE B
OD
Y
GRE
EN
P43
, P61
, P6
8D
ISTR
IBU
TIO
N B
LOW
ERWH
ITE
OR
LT B
LUE
GRE
EN U
SED
ON
ACC
ENTR
A O
NLY
DK
BLU
E O
R BL
ACK AC
CEN
TRA
, P35
i, XX
VD
ISTR
IBU
TIO
N B
LOW
ER
BLACK
WH
ITE
WHITE
BLAC
K B
LUE
SPLI
TTER
SKY
BLU
E
SPLI
TTER
GREEN
GREEN
GRE
EN/Y
ELLO
WAC
C52i
/P35
i
GREEN
WHITE
WH
ITE
DK
BLU
E
RED
WH
ITE
BRO
WN
PRES
SURE
SW
ITCH
N
O C
ON
TAC
TS
COM
BUST
ION
MO
TOR
FEED
MO
TOR
52i D
ISTR
IBU
TIO
N B
LOW
ERS
MA
LE/F
EMA
LE C
ON
NEC
TIO
NS
GRE
EN W
IRE
IS G
ROU
ND
BON
DED
TO
MO
UN
TIN
G F
RAM
E
ACC5
2i /
P35i
GRE
EN
5 A
MP
CERA
MIC
FU
SE (5
X20M
M)
HA
RMA
N #
1-00
-052
37BU
SSM
AN
BK/
S501
-5-R
OR
LITT
ELFU
SE 0
2160
05.M
XP
21
-
Harman® • P35i-C Installation Manual_R5 • 2019 -___ • 03/2128
8390-784i
352MountainHouseRoad,Halifax,PA17032www.harmanstoves.com
PleasecontactyourHarman® dealer with any questions or concerns.
ForthelocationofyournearestHarman® dealer,
please visit www.harmanstoves.com.Printed in U.S.A