Page 1
ContentsImportantUserInformation...........................2General........................................2Manufacturer....................................2Warranty .......................................2CeilingandWallPanelPlacementandDesign..........2IntendedUse....................................2
SafetyPrecautions .................................3RequiredTools.....................................3PartsLists........................................4CeilingPanelHardwarePackagePartsList............4WallPanelHardwarePackagePartList...............4
BeforeStartingtheInstallation ........................5HandlingPanels ...................................5CleaningPanels ...................................6CleaningUnfinishedPanels ........................6CleaningPaintedPanels...........................6CleaningFabric-CoveredPanels ....................6
PaintingDiffuserPanels .............................6
CeilingPanelSystemDescription......................7CeilingPanelTypes...............................7CeilingPanelSizes...............................7CeilingPanelDefinitions...........................8
WallPanelSystemDescription........................10WallPanelTypes.................................10WallPanelSizes.................................10WallPanelDefinitions.............................11
RigidCeilingInstallation.............................12FastenaClipModelPanelDirectlytoCeiling...........12SuspendtheClipModelPanelfromCeiling............13
StandardCeilingGridLay-InDiffuserPanelInstallation.....15DesignerCeilingGridLay-InDiffuserPanelInstallation.....15WallPanelInstallation...............................18AttachHangerBracketstoWallDiffuserPanels.........18WallPanelLocations..............................19PreparetheWallBrackets..........................20AttachtheWallBrackets...........................21AttachtheWallPaneltotheWall....................24
Ceiling Panel Wall Panel
©WengerCorporation2016 PrintedinUSA12/16 Part#161H169-01
Wenger Corporation,555ParkDrive,P.O.Box448,Owatonna,Minnesota55060-0448Questions?Call.....USA:800-4WENGER(493-6437)•Worldwide:1-507-455-4100•www.wengercorp.com
Note: Pleasereadandunderstandtheinstructionsbeforestartingtheassemblyorinstallation.Note: Ifyouneedadditionalinformation,contactWengerCorporationusingtheinformationbelow.
InstallationInstructions
Ceiling and Wall Acoustical Panels
Page 2
2
Important User InformationGeneralCopyright©2016byWengerCorporation
Allrightsreserved.Nopartofthecontentsofthismanualmaybereproduced,copied,ortransmittedinanyformorbyanymeansincludinggraphic,electronic,ormechanicalmethodsorphotocopying,recording,orinformationstorageandretrievalsystemswithoutthewrittenpermissionofthepublisher,unlessitisforthepurchaser’spersonaluse.
PrintedandboundintheUnitedStatesofAmerica.
TheinformationinthismanualissubjecttochangewithoutnoticeanddoesnotrepresentacommitmentonthepartofWengerCorporation.WengerCorporationdoesnotassumeanyresponsibilityforanyerrorsthatmayappearinthismanual.
InnoeventwillWengerCorporationbeliablefortechnicaloreditorialomissionsmadeherein,norfordirect,indirect,special,incidental,orconsequentialdamagesresultingfromtheuseordefectofthismanual.
Theinformationinthisdocumentisnotintendedtocoverallpossibleconditionsandsituationsthatmightoccur.TheendusermustexercisecautionandcommonsensewhenassemblingorinstallingWengerCorporationproducts.Ifanyquestionsorproblemsarise,callWengerCorporationat1-800-887-7145.
ManufacturerTheAcousticalPanelsaremanufacturedby:
WengerCorporation 555ParkDrive,Owatonna,MN55060 800-4WENGER(493-6437)•1-507-455-4100www.wengercorp.com
WarrantyThisproductisguaranteedfreeofdefectsinmaterialsandworkmanshipforfivefullyearsfrom dateofshipment.Afullwarrantystatementisavailableuponrequest.
Ceiling and Wall Panel Placement and DesignWengerAcousticalWallandCeilingPanelsshapetheacousticpropertiesofaroom. CorrectplacementofAbsorptionandDiffusionPanelsinaroomreduceunwantedreflections, filldead-spotsandadjustreverberationlevelstotheoptimumforthesoundsource.
Theacousticdesignofaroommustbetailoredtotheroom’sshape,size,constructionandplanneduse.SimplyaddingCeilingandWallPanelsmaynotachievethedesiredacousticperformance.ArrangingCeilingandWallPanelsbasedontheirvisualappearancesimilarlymaynotachievethebestsoundqualitywithintheroom.ThebestacousticcharacteristicscanbeobtainedbyconsultingWengerCorporationoranexperiencedacousticianandthendevelopinganacousticdesignfortheroom.
Intended Use• WengerAcousticalWallandCeilingPanelsareintendedforindooruseinnormalambienttemperature andhumidityconditionsandmustnotbeexposedtoopenflamesorhotlightingfixtures.• WengerAcousticalWallPanelsareintendedtobepermanentlyattachedtopermanentwallstructures onlyasdescribedintheseinstructions.• WengerAcousticalCeilingPanelsareintendedtobepermanentlyattachedtopermanentceiling structuresasdescribedintheseinstructions.
Page 3
3
Safety Precautions
Make sure anyone installing the Acoustical Panels has read and understands these instructions.
! CAUTION
ThroughoutthismanualyoumayfindCAUTIONSandWARNINGSwhicharedefinedasfollows:
• WARNINGmeansthatfailuretofollowtheinstructionmayresultinseriousinjuryordeath. • CAUTION meansthatfailuretofollowtheinstructionmayresultinseriousinjuryordamage toproperty.
ReadallofthesesafetyinstructionsbeforeinstallingtheAcousticalPanels.
Failure to comply with Warnings and Cautions in this document can result in damage to property or serious injury.
! CAUTIONAlways wear safety glasses, protective head gear, safety shoes and use heavy work gloves when installing the Acoustical Panels.
! CAUTION
The Panels are constructed from molded thermoplastic materials and can be covered with polyester fabric or paint. Do not allow open flames or very hot lighting to come into close proximity to any Acoustical Panels. Lighting that is close to an Acoustical Panel must not exceed 176°F (80°C).
! WARNING
Required Tools
SomeofthefollowingtoolsarerequiredforinstallationofWallandCeilingPanels. Refertotheinstallationinstructionsforspecificinformation.
Cordless Drill#2 Phillips Bit #2 Phillips Screwdriver
#30 Drill Bit Number 2B Pencil
8’ Tape Rule Blind Rivet Tool Plumb Bob
Carpenter’s Box Level Chalk Line
Page 4
4
Ceiling Panel Hardware Package Part List
Item Description
1 PanHeadScrew,6-20x1/2” (not included with Lay-In Panels)
2 CeilingMountClipOnBracket (not included with Lay-In Panels)
3 CeilingMountWireHangerBracket (not included with Lay-In Panels)
4 CeilingMountDesignerGridBracket (not included with Clip Model Panels)
5 SafetyCableAssembly (not included with Clip Model Panels)
Note:Items 1-3 not included with Lay-in Panels.Items 4-5 not included with Clip Model Panels.Absorber Panels include all hardware
EachCeilingPanelisfurnishedwithahardwarepackagethatcontainsthefollowingparts. Quantitiesmayvary,partsnotrequiredforinstallationcanbediscarded.
Wall Panel Hardware Package Part ListEachWallPanelisfurnishedwithahardwarepackagethatcontainsthefollowingparts. Quantitiesmayvary,partsnotrequiredforinstallationcanbediscarded.
Item Description1 PanHeadScrew,6-20x1/2”2 DiffuserWallHangerBracket3 WallBracket
5
Parts Lists
Page 5
5
Handling PanelsUnfinished,painted,andfabriccoveredpanelsurfacesareeasilysoiled. Roughhandlingcaneasilydamagepanelsanddegradetheacousticproperties. WhenhandlingandinstallingAcousticalPanels,dothefollowing.• Alwayskeeptheentireinstallationsiteandinstallationtoolsascleanaspossible.• GlovesareprovidedwiththePanels.Alwayswearthesegloveswheneverhandlingthepanels.• Handlepanelswithcaretopreventphysicaldamage.• Twopeoplemustalwaysworktogetherwhenhandlinglargepanels.• HoldAbsorberpanelsbytheedgewhenhandlingorinstalling.• NevercompresstheAbsorberPanelabsorptionmaterialonthepanelface(itwillcrushand notreturntotheoriginalshapeanddegradetheacousticproperties).
1. Makesurethatallpersonnel(includingtemporarylabor)installingAcousticalPanelsreadandunderstandthewarnings,cautions,andinstallationinstructions.
2. Consultlocalbuildingcodesandfirecodesbeforestartingtheinstallation.3. UsetheinstallationdrawingsuppliedbyWengerCorporationorthearchitectshowingthelocation
andorientationofeachPanel.4. Removeallitemsfromtheshippingcontainersandmakesurethatallpartsincludingthefasteners
andaccessoriesintheHardwarePackagesarepresent.RefertotheHardwarePackagePartList.6. Ifproblemsareencounteredduringtheinstallation,callWengerCustomerService
at(800)733-0393.
Before Starting the Installation
Never modify or drill additional holes in panels. Possible damage to the panel structural integrity can result.
! CAUTION
Page 6
6
Cleaning PanelsCleaning Unfinished PanelsCleanunpainted,whiteplasticDiffuserPanelswithanon-abrasive,milddetergentorhousehold-windowcleaner.Difficulttoremovestainscanberemovedwithamildly-abrasivehouseholdcleanerifitisappliedgently.Applythemildly-abrasivehouseholdcleanerwithgentlecaretoavoidhazingorscratchingthepanelfinish.
Cleaning Painted PanelsCleanpaintedplasticDiffuserPanelsonlywithmildsoapywater.Ifitisnecessarytouseacommercialcleanertoremoveadifficultstain,trythecleaneronahiddenareafirsttoseeifthepaintisaffectedbythecleaner(tomakesurethatthecleanerdoesnotbleachorremovethepaintentirely).
Cleaning Fabric-Covered PanelsCleanfabric-coveredpanelsbyvacuumingwithasoftbrushattachmentorusingalow-pressureairnozzleoutdoorsorinawellventilatedspace.
TheWengerstandardfabricispolyester.Stainscanberemovedbyusingafabriccleanerdesignedforpolyester.Blottingasoiledareaisrecommended.Brushingorotheraggressivemethodscandamagethefabricandshouldbeavoided.ItisalwaysagoodpracticetotestthecleaningmethodandsolutiononthebacksideofthePaneltomakesurethatthefabriccolor,texture,andadhesionarenotaffected.
Tocleancustomfabrics,useonlycleanersandmethodsthatarerecommendedbythefabricmanufacturer.
Cleaning Absorber PanelsNeveruseexcessiveamountsofwaterorliquidcleanersonabsorberpanels.Absorberpanelsabsorbliquidsandrequiredextendedtimetodrypromotingmoldandmildewgrowth.
Painting Diffuser PanelsUnpaintedDiffuserPanelscanbepaintedwithoutsignificantlyreducingtheacousticalperformance.Alwaystestthepaintorstainonasmallhiddenareaofthepanelfirst.
TopaintaDiffuserPanel,doasfollows.1. Selectaflat,satin,semi-gloss,orhigh-glosslatexoracrylic-latexpaintsuitableforexteriorsurfaces.2. CleananddrytheDiffuserPanelsurfacetobepainted.3. Applythepaintatambienttemperaturesbetween50°Fand90°F,atleast5°Fabovethedewpoint,
andwiththerelativehumiditylessthan85%.a. Applythefirstcoatofpaintwithabrushandallowthepainttodry.b. Applythesecondcoatofpaintwitharollerorpaintsprayer.
4. ToapplyastaintoDiffuserPanel,cleanthesurfaceandthenfollowthemanufacturer’srecommendedapplicationinstructions.
5. Unplugalldrainholesafterpaintingpanels.
When painting Panels, always work outside or in a well ventilated space.
! CAUTIONSolvent based coatings containing aromatic hydrocarbon solvents such as lacquers or enamels are not recommended for use on PVC substrates.
! CAUTION
Page 7
7
Ceiling Panel System DescriptionCeiling Panel TypesWengerCorporationmanufacturesdifferenttypesofCeilingPanels.
· Type I Convex Diffuser Panel—constructedwithacompositionmaterialthatispoly-cylindrical inshape,thePanelscattersandblendsmid-rangetohigh-rangeaudiofrequencies.· Quadratic Diffuser Panel—constructedofrecycledmoldedthermoplastic,thePanelscatters andblendsaudiofrequenciesfrom750Hertzto3300Hertz.ThesePanelsareavailableonly asa4’x4’sizetofitintoLay-inCeilingGridSystems.· Pyramid Diffuser Panel—constructedofrecycledmoldedthermoplastic,thePanelisshapedlike anoffsetpyramidandisusedtoshapespecificacousticalapplications.· Absorber Panels —constructedofsound-absorptive,fabric-covered,glass-fibermaterialthatis flatinshape,thePanelabsorbsabroadrangeofaudiofrequencies.Ceiling Panel Sizes
2x2 Convex Clip Model 22.750”x22.750” (57.8x57.8cm)
4x2 Convex Clip Model 23.125”x46.875” (58.7x119cm)
4x4 Convex Clip Model 46.750”x46.750” (118.7x118.7cm)
4x4 Pyramid Clip Model 46.750”x46.750” (118.7x118.7cm)
4x4 Pyramid Lay-in Model 46.750”x46.750” (118.7x118.7cm)
4x4 Convex Lay-in Model 46.750”x46.750” (118.7x118.7cm)
4x2 Convex Lay-in Model 23.125”x46.875” (58.7x119cm)
2x2 Convex Lay-in Model 22.750”x22.750” (57.8x57.8cm)
4x4 Low Profile Trapezoid Lay-in Model 47.625”x47.625” (121x121cm)
2x2 Low Profile Trapezoid Lay-in Model 23.625”x23.625” (60x60cm)
Absorber Panel Nominal2’sizeis23.15”(56.3cm) Nominal3’sizeis35.15”(89.3cm) Nominal4’sizeis46.90”(119.1cm) AbsorberPanelscanbeorderedandbuilttoexactoutsidedimensions.
Page 8
8
Absorber Ceiling Panel Flat,fabriccoveredpanelthatabsorbssoundandreducesreverberation.ThisPanelusesMountingClipsforinstallation.
Convex Clip Model Ceiling Panel Poly-cylindricaldiffuserpanelthatscatterssound. ThePanelusesMountingClipsorHangerBracketstoattachdirectly totheceilingorsuspendfromceilinghardware.
Convex Lay-in Model Ceiling Panel Poly-cylindricaldiffuserpanelthatscatterssound. ThePanelhasaflangeontheperimeterthatallowsrestingthe paneldirectlyintoastandardceilinggrid. DesignerGridClipscanbeattachedsothepanelfitsina designerceilinggrid.
Low Profile Trapezoid Lay-in Model Ceiling Panel Trapezoidalshapeddiffuserpanelthatscatterssound. ThePanelhasaflangeontheperimeterthatallowsrestingthe paneldirectlyintoastandardceilinggrid. DesignerGridClipscanbeattachedsothepanelfitsina designerceilinggrid.
Ceiling Grid Gridrailsconnectedatrightanglestoeachother,suspendedfrom theceilingwithhardware.ThegridrailsallowCeilingPanelstorest ontherails.
Ceiling Panel System Description (continued)Ceiling Panel Sizes (continued)Mostdomesticsuspendedceilinggridsystemshavegridrailson2’squarecenters(61cm), 2’x4’centers(61x122cm),or4’(122cm)squarecenters. ThisallowstheinstallationofEnglishsizedtwo-footbytwo-foot,two-footbyfour-foot,andfour-footbyfour-footCeilingPanelstomatchthecenter-to-centergriddistance.
ManyofWengerCeilingPanelsaremadespecificallyforsuspendedgridceilingsystemsandarereferredtobytheirEnglishgridsizesuchas2x2(two-footbytwo-foot).Theactualsizeofthese Panelsisdifferentthanthenominalsize.A2x2CeilingPanelisactuallyslightlysmallerthantwo-feet bytwo-feettoallowforthegridrailtofitbetweentheCeilingPanels.
AbsorberPanelsareavailableincustomsizesthatarebuilttoexactoutsidedimensionsthatarespecifiedonthepanelpurchaseorder.
Ceiling Panel Definitions
Due to their weight, never install Ceiling Panels that are larger than 4’ x 4’ into a suspended ceiling grid system.
! CAUTION
Page 9
9
Standard Ceiling Grid Rail Gridrailflangeis15/16”orgreaterandisadequateforsupportingaLay-inPanelFlange.
Designer Ceiling Grid Rail Gridrailflangeislessthan15/16”andisnotadequateforsupportinga Lay-inPanelFlange.
Designer Grid Mounting Clip Ahookshapedbracketwithclearanceholesthatallowsattachingthe brackettoaLay-inModelPanel.ThehookfitsoveraDesignerGridRail.
Safety Cable AsteelcableandcarabinersecuresthePaneltotheCeilingGridfor addedsafetyintheeventofapanelfalling.
Pan Head Screw Phillipssheetmetalpanheadscrew,6-20x1/2”,usedtoattachbracketstotheCeilingPanelCornerBraces.
Mounting Clip AflatbracketwithclearanceholesthatallowattachingthebrackettotheCornerBracesonaClipModelPanel.TheBracketisusedtoattacha PaneldirectlytoaRigidCeiling.
Hanger Bracket AU-shapedbracketwithclearanceholesthatallowsattachingthebracket totheCornerBracesonaClipModelPanel.TheBracketisusedtosuspendPanelsfromtheceilingwithhardwaresuppliedbytheenduser.
Ceiling Panel System Description (continued)Ceiling Panel Definitions (continued)
Rail Flange is greater than
15/16” (2.38 cm)
Rail Flange is less than
15/16” (2.38 cm)
Rigid Ceiling (not shown) Anon-gridsuspendedceilingthatisintegraltothebuildingstructure(suchastrussanddeckconstruction)orisrigidlyattachedtothebuildingstructurewithoutremovablepanels.
Suspended Ceiling (not shown) Asystemofrails(CeilingGrid)andremovableceilingpanelscommonlyusedfortheeaseof installationandlowcost.
Page 10
10
Wall Panel System Description
4x2 Convex Panel 23.125”x46.875”’ (58.8x119cm)
3x3 Convex Panel 35.250”x35.250” (89.5x89.5cm)
3x4 Convex Panel 35.250”x47.000” (89.5x119.4cm)
3x6 Convex Pane 35.250”x70.813” (89.5x180cm)
2x2 Convex Panel 22.750”x22.750” (57.8x57.8cm)
4x4 Pyramid Panel 46.750”x46.750” (118.7x118.7cm)
4x3 Convex Panel 35.250”x47.000” (89.5x119.4cm)
4x4 Convex Panel 46.750”x46.750” (118.7x118.7cm)
4x6 Convex Panel 47.000”x70.875” (119.4x180cm)
4x8 Convex Panel 46.875“x94.750” (58.8x240.7cm)
Absorber Panel Nominal2’dimensionis23.15”(56.3cm) Nominal3’dimensionis35.15”(89.3cm) Nominal4’dimensionis46.90”(119.1cm) Nominal5’dimensionis58.90”(149.6cm) Nominal6’dimensionis70.90”(180cm) Nominal8’dimensionis94.90”(240.7cm)
AbsorberPanelscanbeorderedandbuilttoexactoutsidedimensions.
Wall Panel TypesWengerCorporationmanufacturesdifferenttypesofWallPanels.
· Type I Convex Diffuser Panel—constructedwithacompositionmaterialthatispoly-cylindrical inshape,thePanelscattersandblendsmid-rangetohigh-rangeaudiofrequencies.· Type II Convex Diffuser Panel—similartobutlargerthantheTypeIDiffuserPanel. TheTypeIIPanelperformsliketheTypeIPanelbutalsoabsorbssomelow-rangeaudiofrequencies.· Pyramid Diffuser Panel—constructedofrecycledmoldedthermoplastic,thePanelisshapedlike anoffsetpyramidandisusedtoshapespecificacousticalapplications.· Absorber Panels —constructedofsound-absorptive,fabric-covered,glass-fibermaterialthatis flatinshape,thePanelabsorbsabroadrangeofaudiofrequencies.
Wall Panel SizesWengerConvexDiffuserWallPanelsaremadetoattachdirectlytoapermanentwallstructureandarereferredtobytheirEnglishsizesuchas2x2(two-footbytwo-foot).TheactualsizeofthesePanelsisdifferentthanthenominalsize.A2x2CeilingPanelisactuallyslightlysmallerthantwo-feetbytwo-feet.AbsorberPanelsareavailableincustomsizesthatarebuilttoexactoutsidedimensionsthatarespecifiedonthepanelpurchaseorder.
Page 11
11
Wall Panel System Description (continued)Wall Panel Definitions
Absorber Wall Panel Flat,fabriccoveredpanelthatabsorbssoundandreducesreverberation.ThisPanelusesWallMountingBracketsforinstallation.
Convex Model Wall Panel Poly-cylindricalshapeddiffuserpanelthatscatterssound. ThisPanelusesWallMountingBracketsforinstallation.
Pyramid Model Wall Panel Pyramidshapeddiffuserpanelthatscatterssound. ThisPanelusesWallMountingBracketsforinstallation.
Wall Bracket OffsetmetalrailthatattachestothewallandreceivestheWallPanelHangerBracketswheninstallingtheWallPanel.
Hanger Bracket Z-shapedbracketthatattachestotheDiffuserWallPanelCornerBracesandengages theWallBracketatinstallation.
Pan Head Screw Phillipssheetmetalpanheadscrew,6-20x1/2”,usedtoattachbracketstotheWallPanelCornerBraces.
Page 12
12
Rigid Ceiling InstallationFasten a Clip Model Panel Directly to CeilingClipModelDiffuserandAbsorberPanelsattachdirectlytotheCeilingasfollows.1. AttachoneMountingCliptoeachCornerBracewithtwoSheetMetalScrews,6-20x1/2”,
asshowninIllustration#1below.TheCeilingMountingHolemustbeoutsideofthePanelperimeter.Note: InstallMountingClipsonlyontwosidesofthePanelasshowninIllustration#1.2. HoldthePanelagainsttheceilingintheexactinstallationpositionandmarkthecenteroftheeach
CeilingMountingHoleasshowninIllustration#2below.
2
Clip Model Panel
Clip Model Panel
Mark the four Ceiling Mounting Hole locations on the ceiling.
Mounting ClipMounting Clip
Pan Head Sheet Metal Screw, 6-20x1/2”Ceiling Mounting Hole
Ceiling Mounting Hole
Corner Brace
Corner Brace
Clip Mounting Holes
3. AttachthePaneltotheceilingusingan appropriatefastener(notsupplied).
Note: Ceilingconstructionandmaterialsvary. Alwaysconsultlocalcodesorbuilding materialsuppliersforinformationregarding thecorrectfastener.
3
1
Clip Model Ceiling Panel
Attach to ceiling with a fastener in each Mounting Hole.
Ceiling Mounting Fastener
(not supplied)
Mounting Clip
Mounting Clip
Ceiling Mounting Holes
Make sure that the hardware supplied by the end user is capable of supporting the Panels and is safely anchored. Because ceiling construction such as Tectum® or acoustical tile may not be capable of supporting the Panel weight, make sure the fastener extends into a substrate or structural member capable of supporting the Panel.
! CAUTION
Never attach Wall Panels to a ceiling or horizontal surface. Wall Panels do not have drainage and can fill with water. It is not permissible to drill drainage holes in Wall Panels.
! CAUTION
When attaching Mounting Clips to a Clip Model Panel, always install two Clips on opposite sides. Never attach only one Clip on each side.
! CAUTION
Page 13
13
Rigid Ceiling Installation (continued)Suspend the Clip Model Panel from Ceiling1. HoldthePanelagainsttheceilinginit’sexactmountingpositionanddrawanoutlinearoundthe
PanelperimeterasshowninIllustration#1below.Useaplumbbobtomarkthecornersifthe Panelcannotbeheldagainsttheceiling.
2. Markfourpoints,4-1/2”(11.43cm)insideeachsideofthePanelperimeterasshown intheIllustration#2below.
4-1/2” (11.43 cm)
4-1/2” (11.43 cm)
Mark four points inside the Panel perimeter
2
Panel Perimeter Mark the Clip-mounted Panel
perimeter onto the Ceiling.
1
3. AttachoneHangerBrackettoeachCornerBracewithtwoPanHeadScrews,6-20x1/2”, asshownintheIllustration#3below.
Hanger Bracket and
Panel Corner Brace
3
Hanger Bracket
Pan Head Screw, 6-20x1/2”
Panel Corner Brace
Panel Perimeter
Page 14
14
Rigid Ceiling Installation (continued)
Suspend the Clip Model Panel from Ceiling (continued)4. Attachfasteners(notsuppliedbyWengerCorporation)totheceilingatthefourpoints
markedinsidethePanelPerimeterinStep2onthepreviouspage.
5. Usingwire,cable,orsomesuitablematerial(notsuppliedbyWengerCorporation), attachthefourHangerBracketstothefourfastenersasshownintheIllustration#5below (orbysomeothersafemethod).
Eyebolt or other suitable fastener supplied by the end user
Wire or other suitable material supplied by the end user
Hanger Bracket
Wire or other suitable material supplied by the end user
5
Make sure that the hardware supplied by the end user is capable of supporting the Panels and is safely anchored. Because ceiling construction such as Tectum® or acoustical tile may not be capable of supporting the Panel weight, make sure the fastener extends into a substrate or structural member capable of supporting the Panel.
! CAUTION
Page 15
15
Standard Ceiling Grid Lay-In Diffuser Panel InstallationLay-inModelCeilingPanelsareinstalledintothestandardceilinggridwithoutadditionalhardware.1. InsertaLay-inModelCeilingPanelupwardthroughtheceilinggridasshowninIllustration#1.
2
1
Ceiling Grid
Lay-in Model Ceiling Panel
Lay-in Model Ceiling Panel Flange
Standard Ceiling Grid
2. OrienttheCeilingPanelabovetheceilinggridandlowerthePanelintothegridmakingsure thatallfourflangesonthePanelrestonthegridrailsasshowninIllustration#2below.
3. CliptheprovidedSafetyCablesonthePanelontothenearestSuspensionWire.
Lay-in Model Ceiling Panel Flange
Standard Ceiling Grid
The provided safety cables must be used in all suspended ceiling grid installations.
! CAUTIONMake sure that all four Ceiling Panel Flanges rest on the grid walls.
! CAUTION
Suspension Wire
Safety Cable
Only Flanged Ceiling Panels may be installed into suspended ceiling grids. Make sure that all four Ceiling Lay-in Panel Flanges rest on the ceiling grid rail flange.
! CAUTION
In the event of a Ceiling Panel failure, check the suspended ceiling grid and panel for damage. Do not reinstall a damaged Ceiling Panel.
! CAUTION
Page 16
16
1/4” (0.64 cm)
1-1/2” (3.81 cm)
1/8” Blind Rivet
Drilled Hole (#30 or .1285”
diameter)
Lay-in Diffuser Panel
Designer Grid Mounting Clip
Designer Grid Mounting Clip
Rivet Clearance Holes
1a
8” (20 cm)
Designer Ceiling Grid Lay-In Diffuser Panel Installation1. AttachtheDesignerGridMountingClipstotheLay-inPanelasfollows.
a. UsingaDesignerGridMountingClipasatemplate,markfourholelocationsononeflange ofaDiffuserPanelasshowninIllustration#1abelow.Eachtwo-holepatternshouldbeabout8”(30cm)fromtheendofthepanel.
b. Usinganumber-30drillbit(0.1285”),drillfourholesintheLay-inDiffuserPanelFlange asshowninIllustration#1bbelow.
c. Usingablindrivettool,attacheachDesignerGridMountingCliptotheLay-inPanelFlange byinsertingtwo1/8”BlindRivetsupwardthroughthetwoDrilledHolesandthetwoMountingClipRivetClearanceHoles.
d. RepeatstepsatocontheoppositeLay-inPanelflange.
Do not install a Lay-in Diffuser Panel into a designer grid without attaching the Designer Grid Mounting Clips. Do not install a single Clip on each Panel flange. Install two Clips on one flange and two Clips on the opposite flange.
! CAUTION
1b
Page 17
17
Designer Ceiling Grid Lay-In Diffuser Panel Installation2. InsertaLay-inDiffuserModelCeilingPanelwithDesignerGridMountingClipsupwardthrough
theceilinggrid.
Designer Grid Mounting Clip
Lay-in Diffuser Panel
Designer Ceiling Grid
3. OrienttheDiffuserCeilingPanelabovetheceilinggridandlowerthePanelintothegridmaking surethatallfourDesignerGridMountingClipsonthePanelrestonthegridrailsasshownbelow.
4. CliptheprovidedSafetyCablesonthePanelontothenearestSuspensionWire.
Clip Model Ceiling Panel
Ceiling Grid
Designer Grid Mounting Clip
2
3
Designer Grid Mounting Clip
Designer Ceiling Grid
The provided safety cables must be used in all suspended ceiling grid installations.
! CAUTIONMake sure that all four Mounting Clips rest on the grid. Improperly placed Ceiling Panels can fall.
! CAUTION
Suspension Wire
Safety Cable
Only Flanged Ceiling Panels may be installed into suspended ceiling grids. Make sure that all four Ceiling Lay-in Panel Flanges rest on the ceiling grid rail flange.
! CAUTION
In the event of a Ceiling Panel failure, check the suspended ceiling grid and panel for damage. Do not reinstall a damaged Ceiling Panel.
! CAUTION
Page 18
18
Wall Panel InstallationAttach Hanger Brackets to Wall Diffuser PanelsHangerBracketsarealreadyinstalledonWallAbsorberPanels.
ForWallDiffuserPanels,fourHangerBracketsmustbeattached toeachPanelbeforeinstallationasfollows.
1. PlacethePanelfacedownonaclean, dryworksurface.
2. PlaceamarkonthebackinsideofthePanel closetothebottomedgeindicatingthebottom ofthePanelafteritisinstalled.
3. Usingaphillipsscrewdriver,attachfour HangerBracketstothePanelusingfour PanHeadScrews,6-20x1/2”,asshown inIllustration#3below.a. OrienttheOffsettowardthebottomof
thePanel.b. Theoffsetmustbeawayfromthe
PanelCornerBrace.c. Usetheupper pair of Mounting Holes
onPanelCornerBracket.
Hanger BracketWall
Panel
Panel Bottom Edge
3
Pan Head Screw, 6-20x1/2”
Hanger Bracket
Offset
Corner Brace
Hanger Brackets
Place a mark toward the bottom edge of the Panel. The mark can be on a Corner Brace, on the inside edge, or any where inside the Panel close to the bottom edge.
1-2
Bottom Edge
Wall Absorber Panel
Wall Diffuser Panel
Make sure that the Hanger Brackets are firmly attached in the correct locations.
! CAUTION
Page 19
19
Wall Panel Installation (continued)Wall Panel LocationsDetermineandmarkthecenterlineofeachPanellocationasshownonthearchitecturaldrawings fortheinstallation.
Thefollowingexamplecanbefollowedifdrawingshavenotbeensubmittedwiththepanels. ThisexampleconsidersasinglerowofConvexPanelsequallyspacedacrossawallwiththe spacingbetweenpanelsequaltothespacebetweenthecornersandadjacentpanel. Refertotheillustrationbelow.
Note: AfterthePanelsareinstalled,itmaybenecessarytoadjustthepositionofthePanels toobtaintheoptimumaudioperformance.
Onewaytocalculatethecenterlinelocationsisasfollows.
1. Measurethelengthofthewall.
2. MeasurethewidthofthePanel.
3. MultiplythenumberofPanelstimesthePanel Width.
4. SubtractthetotalofthePanelWidthsfromstep3fromtheLengthoftheWall. CallthisvaluetheFree Space.
5. DividetheFree SpacebythenumberofPanelsplusone.Thatis,iftherearethreepanels intherow,addonetocreateavalueoffour.Inthisexample,dividetheFree Spacebyfour.
6. TheresultingvalueisthePanel Spacingwhichisthedistancebetweenacornerand adjacentpanelorbetweenthePanels.
Otherspacingpatternscanbedeveloped. ActualPanellocationsshouldbedetermined bytheroom’sshape,size,constructionmaterials andotherfactors.
Forthebestroomaudioperformance,thelocationofPanelsshouldbe recommendedbyWengerpersonneloracousticiansfamiliarwiththeproject.
Panel Spacing
Panel Spacing
Panel Spacing
Panel Spacing
Panel
Panel Width
Panel Width
Panel Width
Corner
Wall
Floor
Page 20
20
Wall Panel Installation (continued)Prepare the Wall BracketsWallPanelsmustbeattachedtowallsusingtheWallBracketsthataresuppliedwiththeWallPanels.
ThebracketsthatareshippedwithWallPanelsare42.250”(107.32cm)longand mustbemodifiedtomatchthePanelWidth.
1. EachWallBrackethasscoremarksthatmatchthebracketlengthsrequiredtoattachthe Paneltoawall.
2. BendeachBracketontheappropriatescoremarktoshortenthelength.3. Refertotheillustrationbelow.
18.250” (46.36 cm)22.250” (56.52 cm)26.250” (66.68 cm)30.250” (76.84 cm)34.250” (87.00 cm)38.250” (97.16 cm)42.250” (107.32 cm)
Use this end of the Wall Bracket.
Discard this end of the Wall Bracket.
Typical Score
Panel WidthBracket Width
Panel WidthBracket WidthFrom
Less Than From
Less Than
19.5” 23” 18.25” 35” 39” 34.25”23” 27” 22.25” 39” 43” 38.25”27” 31” 26.25” 43” 47” 42.25”31” 35” 30.25” 47” 95” 18.25”
Hanger Bracket
Mounting Hole
Mounting Hole
Page 21
21
Wall Panel Installation (continued)
Attach the Wall BracketsTwoWallBrackets,oneatthePaneltopandoneatthePanelbottommustbeattachedtothewall tosupporttheweightofthePanelandtoholditagainstthewall.
BeforeinstallingtheWallBrackets,consultthearchitecturaldrawingstodeterminetheWallPanellocationsanddistancefromtheceiling.
Note: ThetopoftheWallPanelcannotbeattachedcloserthan3/4”(1.91cm)totheceiling oranyotherobject. ToengagetheWallBracket,theWallPanelHangerBracketloweredgemustbelifted 3/4”(1.91cm)higherthantheWallBracketTopEdge.
To install the Top Wall Bracket:1. DeterminewheretheheightofthetopedgeoftheWallPanelwillbe. Measuredown6-1/4”(15.875cm)andmarkthelocation.
ThiswillbethebottomedgeoftheTopWallBracket.2. DeterminewheretheleftedgeoftheWallPanelwillbe. Measurein2-1/2”(6.35cm)andmarkthelocation.
TheWallBracketsits2-1/2”infromtheedgeofthePanel.Refertotheillustrationbelow.
Wall Panel Location
Bracket Top Line
Top Edge of Wall Panel
Wall
6-1/4” (15.875 cm)
Both Top and Bottom Wall Brackets must be used to hang all Wall Panels.
! CAUTIONOnly use the Brackets supplied with the Panels to attach them to the wall.Only mount the Panels using the procedures in these instructions.
! CAUTION
Bracket Edge Line
Left Edge of Wall Panel
2-1/2” (6.35 cm)
Page 22
22
Wall Panel Installation (continued)
Attach the Wall Brackets (continued)3. AttachtheTopWallBrackettotheWallusingappropriatefasteners(notsupplied).
Note: Constructionandmaterialsvary.Alwaysconsultlocalcodesorbuildingmaterialsuppliers forinformationregardingthecorrectfastener.
• ForWallPanelsshorterthan4’(121.92cm)wide,aligntheTopWallBrackettothe wallmarksandattach.
• WallPanelslongerthan4’(121.92cm)widerequirethattheWallBracketsbesnapped inhalfonascoremarkbeforeattachingtothewall.a. UsethelefthalfoftheWallBracketontheleftsideoftheWallPanelandtherighthalf
oftheBracketontherightsideofthePanel.b. AligntheLeftSidetothewallmarksandattachtothewall.c. DeterminethehorizontalspacefortheRightSideWallBracketbysubtracting5”(12.7cm)
fromthetotalPanellength(2-1/2”infromtheedgeofthePanelonbothsides). Example;6’panel=72”minus5”=67”spanfromtheoutsideofbothWallBrackets.
Leaving5”(2-1/2”oneachside)toaccomodatetheWallPaneledges.d. AttachtheRightBrackettothewallwiththerightside67”straightacrossfromtheleftedgeof
theLeftBracket.Refertotheillustrationbelow.
Make sure that the hardware supplied by the end user is capable of supporting the Panels and is safely anchored.
! CAUTION
Top Edge of Panel
Left Edge of Bracket
2-1/2” (6.35 cm)
Wall Bracket on a Panel Shorter than 4’ (121.92 cm) Wide
Wall Bracket on a Panel Longer than 4’ (121.92 cm) Wide
2-1/2” (6.35 cm) Top Edge of
Wall Bracket
Top Edge of Panel
Left Edge of Bracket
2-1/2” (6.35 cm)
2-1/2” (6.35 cm) Top Edge of Left
Wall BracketTop Edge of Right
Wall Bracket
Page 23
23
Wall Panel Installation (continued)
Attach the Wall Brackets (continued)To install the Bottom Wall Bracket:1. DependingontheWallPanelheight,measuredownfromthe top edge of the Top Bracket and
mark the location for the bottom edge of the Bottom Bracket accordingtothefollowingchart.
Panel Height
Measure down from Top Bracket edge
2’(60.96cm) 16-1/4”(41.275cm)3’(91.44cm) 28-1/4”(71.755cm)4’(121.92cm) 40-1/4”(102.235cm)6’(182.88cm) 64-1/4”(163.195cm)8’(243.84cm) 88-1/4”(224.155cm)
ThiswillbethebottomedgeoftheBottomWallBracket.2. DeterminewheretheleftedgeoftheWallPanelwillbe. Measurein2-1/2”(6.35cm)andmarkthelocation.
TheWallBracketsits2-1/2”infromtheedgeofthePanel.3. AttachtheBottomWallBrackettotheWallusingthesamemethodandprocedureas
theTopWallBracket.Refertotheillustrationbelow.
Bottom Wall Bracket
Bottom Bracket Line
Bottom Wall Bracket
Top Wall Bracket
Page 24
24
Wall Panel Installation (continued)
Attach the Wall Panel to the WallNote: AlwaysinstallthehighestWallPanelfirsttoavoiddebrisfallingontolowerWallPanels.
1. AttachtheWallPanelsbyplacingeachPanelagainstthewallabout1”(2.54cm)above theintendedfinalposition.
2. LowertheWallPaneldownwardguidingthefourHangerBracketsontotheTopandBottomWallBrackets.BesurethatallfourHangerBracketshaveengagedtheWallBrackets.
3. AdjusttheWallPanelhorizontallocationbyslidingthePanelhorizontallytotherightorleft forfinalpositioning. DimplesontheWallBracketspreventmovingtheWallPaneltoofaranddisengagingaHangerBracketfromtheWallBracket.
4. WhentheWallPanelhorizontalpositionisfixed,pullthePaneldownwardtomakesurethattheHangerBracketsareengagedwiththeWallBrackets.
Note: IftheWallPanelsarelowenoughtobeeitheraccidentallyormischievouslydislodged fromtheWallBrackets,contacttheWengerCorporationforrecommendationsregarding additionalsecuringoftheWallPanelstothewall.
Wall Bracket
Hanger Bracket
Dimples
Make sure that the Hanger Bracket is against the Wall Bracket and between Dimples.
View of the Wall Panel Back
Large Panel installation requires that two or more persons work together. Large Panels can be heavy and difficult to handle alone.
! CAUTION
Be sure that all of the Hanger Brackets rest between the Dimples and engage the Wall Brackets.