INSTALLATION INSTRUCTION mUNIT POLE CLAMP...mUnit Pole Clamp is used together with mUnit Base Mount for installation of one mUnit on tower leg or other vertical or horizontal structures
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
mUnit Pole Clamp is used together with mUnit Base Mount for installation of one mUnit on tower leg or other vertical or horizontal structures of various size and shape.
All Enquiries:tel: +44 (0)1744 762 929email: [email protected]: www.etechcomponents.com
All Enquiries:tel: +44 (0)1744 762 929email: [email protected]: www.etechcomponents.com
5. EXAMPLE OF PROFILES ................................................................................................................ 8
1. PRODUCT COVERED IN THISINSTALLATION INSTRUCTION
This installation instruction covers the mUnit Pole Clamp together with the mUnit Base Mount. The mUnit Pole Clamp is made of anodized aluminium and the fasteners are made of acid proof stainless steel. This instruction shows how the mount is assembled and mounted towards the mUnit.
RECOMMENDED TOOLS
Socket 15 mmSocket 17 mmU-Wrench 17 mmTorque wrenchSocket extension (might be needed for pan function mounting)
All Enquiries:tel: +44 (0)1744 762 929email: [email protected]: www.etechcomponents.com
All Enquiries:tel: +44 (0)1744 762 929email: [email protected]: www.etechcomponents.com
Pre-assemble the mUnit Pole Clamp by assembling the M10 x 185 screws, the M10 washers and the M10 nuts.
Do not tighten the screws or nuts until step 5 and 8 of this assembly instruction.
Make sure you turn the back clamp in right posi-tion depending on the shape and size of the tower leg (see mounting examples on page 17).
3
4
Open up the mUnit Base Mount to maximum extent in order to get best accessibility.
Mount the mUnit Pole Clamps to the mUnit Base Mount.
The picture shows the mUnit Pole Clamp position for attaching the unit to a vertical structure. By turning the mUnit Pole Clamp 90 degrees the unit can be attached to a horizontal structure.
5
Tighten the M10 screws to torque 33 Nm (24 lb ft).
All Enquiries:tel: +44 (0)1744 762 929email: [email protected]: www.etechcomponents.com
All Enquiries:tel: +44 (0)1744 762 929email: [email protected]: www.etechcomponents.com
90˚ ANGLE PROFILES 35 x 35-90 x 90 mmFor 90˚ angle frame legs the back clamp profile should be turned with the protruding lips towards the frame member.
60˚ ANGLE PROFILES 40-100 mm For 60˚ angle frame legs turn the back profile with the protruding lips away from the frame member.
5. EXAMPLE OF PROFILES
ROUND TUBES Ø25-120 mmFor tubes Ø25-60 mm the back clamp profile should be turned with the protruding lips towards the tube. For tubes 60-120 mm the lips should be turned away from the tube.
Ø25-60 mm Ø60-120 mm
35 x 35 to 50 x 50 mm 50 x 50 to 90 x 90 mm
SQUARE PROFILES 35 x 35-90 x 90 mmFor square profiles 35 x 35 to 50 x 50 mm the back clamp profile should be turned with the protruding lips towards the frame member. For squares 50 x 50 to 90 x 90 mm the lips should be turned away from the frame member.
Max Ø120 mmMin Ø25 mm
Max 90 x 90 mmMin 35 x 35 mm
Max 90 x 90 mmMin 35 x 35 mm
All Enquiries:tel: +44 (0)1744 762 929email: [email protected]: www.etechcomponents.com