Installation Guide for VIRDI-4000 V3.2
Fingerprint Identification Terminal
Installation Guide for VIRDI-4000 V3.2
Fingerprint Identification Terminal
Doc. Ver. : V1.40Aug.,25.2009
R&D CenterUnion Community Co., Ltd.
Doc. Ver. : V1.40Aug.,25.2009
R&D CenterUnion Community Co., Ltd.
Installation for VIRDIInstallation for VIRDIInstallation for VIRDIInstallation for VIRDI----4000 4000 4000 4000 V3.2V3.2V3.2V3.2
Installation for VIRDIInstallation for VIRDIInstallation for VIRDIInstallation for VIRDI----4000 4000 4000 4000 V3.2V3.2V3.2V3.2
8
Lock1
LockCon1Q203KN2222ASB
EC
R241472R1 2
NC
D204S1A
AK
Strike/AutoDoor
LM_COM2
Motor
AutoDoor
Strike/Motor
DC216104C2
12
Strike/Motor5V
Door Lock InterfaceST/MT
SW203BSI-10
D202S1A
AK
Q205KN2222ASB
EC
PV204VN20-260LJ
12
LockCon2
PV206VN20-260LJ
12
VIN
NO
AutoDoor
R240473R
1 2
K202G6S-2-5VDC
910
8
43
51
12
D201S1A
AK
LM_COM2
DC210104C2
12
SW201BSI-10
DC215104C2
12
SW202BSI-10
R229473R
1 2DC211104C2
12
D205S1A
AK
VIN
Strike/Motor
5V
SW204BSI-10
R228472R1 2
Lock2
VIN
K201G6S-2-5VDC
910
8
43
51
12
5. Schematic for Door Lock Interface 5. Schematic for Door Lock Interface 5. Schematic for Door Lock Interface 5. Schematic for Door Lock Interface
Installation for VIRDIInstallation for VIRDIInstallation for VIRDIInstallation for VIRDI----4000 4000 4000 4000 V3.2V3.2V3.2V3.2
9
6. Connections of harness to terminal blocks 6. Connections of harness to terminal blocks 6. Connections of harness to terminal blocks 6. Connections of harness to terminal blocks
Power CablePower CablePower CablePower CableDoor LockDoor LockDoor LockDoor LockCableCableCableCable
P-
7(BK)
P-
6(OR)
P-
5(BK)
P-
4(GR)
P-
3(YE)
P-
2(BR)
P-
1(RE)
P-
3
P-
2(BK)
P-
1(RE)
Lock.1
Lock.1
Lock.1
Lock.1
Lock.2
Lock.2
Lock.2
Lock.2
Input1
Input1
Input1
Input1
Input2
Input2
Input2
Input2
+12V
+12V
+12V
+12V
GN
DG
ND
GN
DG
ND
FG
FG
FG
FG
GNDGNDGNDGNDExit BExit BExit BExit B
RS485.B
RS485.B
RS485.B
RS485.B
RS485.A
RS485.A
RS485.A
RS485.A
RS485RS485RS485RS485CableCableCableCable
Installation for VIRDIInstallation for VIRDIInstallation for VIRDIInstallation for VIRDI----4000 4000 4000 4000 V3.2V3.2V3.2V3.2
10
7. Connecting Door Phone 7. Connecting Door Phone 7. Connecting Door Phone 7. Connecting Door Phone
Door PhoneDoor PhoneDoor PhoneDoor PhoneHousingHousingHousingHousing
7 Pin Door Lock 7 Pin Door Lock 7 Pin Door Lock 7 Pin Door Lock HousingHousingHousingHousing
※ The Installation distance is Max 30M(100feet) between VIRDI※ The Installation distance is Max 30M(100feet) between VIRDI※ The Installation distance is Max 30M(100feet) between VIRDI※ The Installation distance is Max 30M(100feet) between VIRDI----4000 and Door Phone.4000 and Door Phone.4000 and Door Phone.4000 and Door Phone.If you want to call the door phone, please use the If you want to call the door phone, please use the If you want to call the door phone, please use the If you want to call the door phone, please use the “ CallCallCallCall” button.button.button.button.
** Inside Open Switch Connection** Inside Open Switch Connection** Inside Open Switch Connection** Inside Open Switch Connection
Installation for VIRDIInstallation for VIRDIInstallation for VIRDIInstallation for VIRDI----4000 4000 4000 4000 V3.2V3.2V3.2V3.2
11
8. Connecting Dead8. Connecting Dead8. Connecting Dead8. Connecting Dead----Bolt Type Door Lock (Fail SafeBolt Type Door Lock (Fail SafeBolt Type Door Lock (Fail SafeBolt Type Door Lock (Fail Safe) ) ) )
ONONONON
WnPWnPWnPWnP
1111 2222 3333 4444
---- CCCC ++++
(-)Black
(+)Red
Door Monitor
Lock(+)
Inside Door Open S/WInside Door Open S/WInside Door Open S/WInside Door Open S/W
8.1. Connect with One System/ One Lock
Lock Type Select S/WLock Type Select S/WLock Type Select S/WLock Type Select S/W
Installation for VIRDIInstallation for VIRDIInstallation for VIRDIInstallation for VIRDI----4000 4000 4000 4000 V3.2V3.2V3.2V3.2
12
8. Connecting Dead8. Connecting Dead8. Connecting Dead8. Connecting Dead----Bolt Type Door Lock (Fail SafeBolt Type Door Lock (Fail SafeBolt Type Door Lock (Fail SafeBolt Type Door Lock (Fail Safe) ) ) )
ONONONON
WnPWnPWnPWnP
1111 2222 3333 4444
---- CCCC ++++
(-)Black
(+)Red
Door Monitor
8.2. Connect with Two Systems/ One LockSystem 2System 2System 2System 2System 1System 1System 1System 1
Lock(+)
Lock(-)
Input1
Lock(+)
Lock(-)
Input1
System 2System 2System 2System 2System 1System 1System 1System 1
Lock
1 (
RE
) -
1Lo
ck 2
(B
R)
-2
Inp
ut1
(Y
E)
-3
Inp
ut2
(G
R)
-4
GN
D (
BK
) -
5E
xit
B (
OR
) -
6G
ND
(B
K)
-7
Lock
1 (
RE
) -
1Lo
ck 2
(B
R)
-2
Inp
ut1
(Y
E)
-3
Inp
ut2
(G
R)
-4
GN
D (
BK
) -
5E
xit
B (
OR
) -
6G
ND
(B
K)
-7
Pin
1
Pin
5
Pin
3
Pin
1
Pin
2
Pin
3
Lock Type Select S/WLock Type Select S/WLock Type Select S/WLock Type Select S/W
SW2SW2SW2SW2
ONONONON
1111 2222 3333 4444 5555 6666
SW201SW201SW201SW201
NO NC
SW204SW204SW204SW204
ST/M
A/D
SW202SW202SW202SW202
SW203SW203SW203SW203ST/MA/D
Strike Motor
Lock Type Select S/WLock Type Select S/WLock Type Select S/WLock Type Select S/W
SW2SW2SW2SW2
ONONONON
1111 2222 3333 4444 5555 6666
SW201SW201SW201SW201
NO NC
SW204SW204SW204SW204
ST/M
A/D
SW202SW202SW202SW202
SW203SW203SW203SW203ST/MA/D
Strike Motor
Installation for VIRDIInstallation for VIRDIInstallation for VIRDIInstallation for VIRDI----4000 4000 4000 4000 V3.2V3.2V3.2V3.2
13
9. Connecting Strike Type Door Lock (Fail Safe9. Connecting Strike Type Door Lock (Fail Safe9. Connecting Strike Type Door Lock (Fail Safe9. Connecting Strike Type Door Lock (Fail Safe) ) ) )
(-)Black(+)Red
Door MonitorDoor MonitorDoor MonitorDoor Monitor
9.1. Connect with One system/ One Lock
Lock(+)
Lock(-)
Input1
GND
Inside Door Open S/WInside Door Open S/WInside Door Open S/WInside Door Open S/W
Exit B
Lock
1 (
RE
) -
1Lo
ck 2
(B
R)
-2
Inp
ut1
(Y
E)
-3
Inp
ut2
(G
R)
-4
GN
D (
BK
) -
5E
xit
B (
OR
) -
6G
ND
(B
K)
-7
Pin
1
Pin
5
Pin
3
Pin6
Pin7
Lock Type Select S/WLock Type Select S/WLock Type Select S/WLock Type Select S/W
SW2SW2SW2SW2
ONONONON
1111 2222 3333 4444 5555 6666
SW201SW201SW201SW201
NO NC
SW204SW204SW204SW204
ST/M
A/D
SW202SW202SW202SW202
SW203SW203SW203SW203ST/MA/D
Strike Motor
Installation for VIRDIInstallation for VIRDIInstallation for VIRDIInstallation for VIRDI----4000 4000 4000 4000 V3.2V3.2V3.2V3.2
14
9. Connecting Strike Type Door Lock (Fail Safe9. Connecting Strike Type Door Lock (Fail Safe9. Connecting Strike Type Door Lock (Fail Safe9. Connecting Strike Type Door Lock (Fail Safe) ) ) )
9.2. Connect with Two systems/ One Lock
(-)Black
(+)Red
Door MonitorDoor MonitorDoor MonitorDoor Monitor
Lock(+)
Lock(-)
Input1
Lock(+)
Lock(-)
Input1
System 2System 2System 2System 2System 1System 1System 1System 1
Lock
1 (
RE
) -
1Lo
ck 2
(B
R)
-2
Inp
ut1
(Y
E)
-3
Inp
ut2
(G
R)
-4
GN
D (
BK
) -
5E
xit
B (
OR
) -
6G
ND
(B
K)
-7
Lock
1 (
RE
) -
1Lo
ck 2
(B
R)
-2
Inp
ut1
(Y
E)
-3
Inp
ut2
(G
R)
-4
GN
D (
BK
) -
5E
xit
B (
OR
) -
6G
ND
(B
K)
-7
Pin
1
Pin
5
Pin
3
Pin
1
Pin
2
Pin
3
System 2System 2System 2System 2System 1System 1System 1System 1
Lock Type Select S/WLock Type Select S/WLock Type Select S/WLock Type Select S/W
SW2SW2SW2SW2
ONONONON
1111 2222 3333 4444 5555 6666
SW201SW201SW201SW201
NO NC
SW204SW204SW204SW204
ST/M
A/D
SW202SW202SW202SW202
SW203SW203SW203SW203ST/MA/D
Strike Motor
Lock Type Select S/WLock Type Select S/WLock Type Select S/WLock Type Select S/W
SW2SW2SW2SW2
ONONONON
1111 2222 3333 4444 5555 6666
SW201SW201SW201SW201
NO NC
SW204SW204SW204SW204
ST/M
A/D
SW202SW202SW202SW202
SW203SW203SW203SW203ST/MA/D
Strike Motor
Installation for VIRDIInstallation for VIRDIInstallation for VIRDIInstallation for VIRDI----4000 4000 4000 4000 V3.2V3.2V3.2V3.2
15
10. Connecting Strike Type Door Lock (Fail Secure10. Connecting Strike Type Door Lock (Fail Secure10. Connecting Strike Type Door Lock (Fail Secure10. Connecting Strike Type Door Lock (Fail Secure) ) ) )
10.1. Connect with One system/ One Lock
(-)Black
(+)Red
Door MonitorDoor MonitorDoor MonitorDoor Monitor
Lock(+)
Lock(-)
Input1
GND
Inside Door Open S/WInside Door Open S/WInside Door Open S/WInside Door Open S/W
Exit B
Lock
1 (
RE
) -
1Lo
ck 2
(B
R)
-2
Inp
ut1
(Y
E)
-3
Inp
ut2
(G
R)
-4
GN
D (
BK
) -
5E
xit
B (
OR
) -
6G
ND
(B
K)
-7
Pin
1
Pin
5
Pin
3
Pin6
Pin7
Lock Type Select S/WLock Type Select S/WLock Type Select S/WLock Type Select S/W
SW2SW2SW2SW2
ONONONON
1111 2222 3333 4444 5555 6666
SW201SW201SW201SW201
NO NC
SW204SW204SW204SW204
ST/M
A/D
SW202SW202SW202SW202
SW203SW203SW203SW203ST/MA/D
Strike Motor
Installation for VIRDIInstallation for VIRDIInstallation for VIRDIInstallation for VIRDI----4000 4000 4000 4000 V3.2V3.2V3.2V3.2
16
10. Connecting Strike Type Door Lock (Fail Secure10. Connecting Strike Type Door Lock (Fail Secure10. Connecting Strike Type Door Lock (Fail Secure10. Connecting Strike Type Door Lock (Fail Secure) ) ) )
10.2. Connect with Two systems/ One Lock
(-)Black
(+)Red
Door MonitorDoor MonitorDoor MonitorDoor Monitor
System 2System 2System 2System 2System 1System 1System 1System 1
Lock(+)
Lock(-)
Input1
Lock(+)
Lock(-)
Input1
System 2System 2System 2System 2System 1System 1System 1System 1
Lock
1 (
RE
) -
1Lo
ck 2
(B
R)
-2
Inp
ut1
(Y
E)
-3
Inp
ut2
(G
R)
-4
GN
D (
BK
) -
5E
xit
B (
OR
) -
6G
ND
(B
K)
-7
Lock
1 (
RE
) -
1Lo
ck 2
(B
R)
-2
Inp
ut1
(Y
E)
-3
Inp
ut2
(G
R)
-4
GN
D (
BK
) -
5E
xit
B (
OR
) -
6G
ND
(B
K)
-7
Pin
1
Pin
5
Pin
3
Pin
1
Pin
5
Pin
3
Lock Type Select S/WLock Type Select S/WLock Type Select S/WLock Type Select S/W
SW2SW2SW2SW2
ONONONON
1111 2222 3333 4444 5555 6666
SW201SW201SW201SW201
NO NC
SW204SW204SW204SW204
ST/M
A/D
SW202SW202SW202SW202
SW203SW203SW203SW203ST/MA/D
Strike Motor
Lock Type Select S/WLock Type Select S/WLock Type Select S/WLock Type Select S/W
SW2SW2SW2SW2
ONONONON
1111 2222 3333 4444 5555 6666
SW201SW201SW201SW201
NO NC
SW204SW204SW204SW204
ST/M
A/D
SW202SW202SW202SW202
SW203SW203SW203SW203ST/MA/D
Strike Motor
Installation for VIRDIInstallation for VIRDIInstallation for VIRDIInstallation for VIRDI----4000 4000 4000 4000 V3.2V3.2V3.2V3.2
17
11. Connecting EM Type Door Lock (Fail Safe11. Connecting EM Type Door Lock (Fail Safe11. Connecting EM Type Door Lock (Fail Safe11. Connecting EM Type Door Lock (Fail Safe) ) ) )
- (Black)
+ (Red)
Door MonitorDoor MonitorDoor MonitorDoor Monitor
Lock(+)
Inside Door Open S/WInside Door Open S/WInside Door Open S/WInside Door Open S/W
Lock(-)
Input1
GND
Exit B
Lock
1 (
RE
) -
1Lo
ck 2
(B
R)
-2
Inp
ut1
(Y
E)
-3
Inp
ut2
(G
R)
-4
GN
D (
BK
) -
5E
xit
B (
OR
) -
6G
ND
(B
K)
-7
Pin
1
Pin
5
Pin
3
Pin6
Pin7
11.1. Connect with One system/ One Lock
Lock Type Select S/WLock Type Select S/WLock Type Select S/WLock Type Select S/W
SW2SW2SW2SW2
ONONONON
1111 2222 3333 4444 5555 6666
SW201SW201SW201SW201
NO NC
SW204SW204SW204SW204
ST/M
A/D
SW202SW202SW202SW202
SW203SW203SW203SW203ST/MA/D
Strike Motor
Installation for VIRDIInstallation for VIRDIInstallation for VIRDIInstallation for VIRDI----4000 4000 4000 4000 V3.2V3.2V3.2V3.2
18
11.2. Connect with Two System/ One Lock
Lock(+)
Lock(-)
Input1
Lock(+)
Lock(-)
Input1
System 2System 2System 2System 2System 1System 1System 1System 1
Lock
+ (
RE
) -
1Lo
ck-
(BR
) -
2In
pu
t1 (
YE
) -
3In
pu
t2 (
GR
) -
4G
ND
(B
K)
-5
Exi
t B
(O
R)
-6
GN
D (
BK
) -
7
Lock
+ (
RE
) -
1Lo
ck-
(BR
) -
2In
pu
t1 (
YE
) -
3In
pu
t2 (
GR
) -
4G
ND
(B
K)
-5
Exi
t B
(O
R)
-6
GN
D (
BK
) -
7
Pin
1
Pin
2
Pin
3
Pin
1
Pin
2
Pin
3
11. Connecting EM Type Door Lock(Fail Safe11. Connecting EM Type Door Lock(Fail Safe11. Connecting EM Type Door Lock(Fail Safe11. Connecting EM Type Door Lock(Fail Safe) ) ) )
- (Black)
+ (Red)
Door MonitorDoor MonitorDoor MonitorDoor Monitor
System 2System 2System 2System 2System 1System 1System 1System 1
Lock Type Select S/WLock Type Select S/WLock Type Select S/WLock Type Select S/W
SW2SW2SW2SW2
ONONONON
1111 2222 3333 4444 5555 6666
SW201SW201SW201SW201
NO NC
SW204SW204SW204SW204
ST/M
A/D
SW202SW202SW202SW202
SW203SW203SW203SW203ST/MA/D
Strike Motor
Lock Type Select S/WLock Type Select S/WLock Type Select S/WLock Type Select S/W
SW2SW2SW2SW2
ONONONON
1111 2222 3333 4444 5555 6666
SW201SW201SW201SW201
NO NC
SW204SW204SW204SW204
ST/M
A/D
SW202SW202SW202SW202
SW203SW203SW203SW203ST/MA/D
Strike Motor
Installation for VIRDIInstallation for VIRDIInstallation for VIRDIInstallation for VIRDI----4000 4000 4000 4000 V3.2V3.2V3.2V3.2
19
11. Connecting EM Type Door Lock (Fail Safe11. Connecting EM Type Door Lock (Fail Safe11. Connecting EM Type Door Lock (Fail Safe11. Connecting EM Type Door Lock (Fail Safe) ) ) )
- (Black)
+ (Red)
Door MonitorDoor MonitorDoor MonitorDoor Monitor
Lock(+)
Inside Door Open S/WInside Door Open S/WInside Door Open S/WInside Door Open S/W
Lock(-)
Input1
GND
Exit B
Lock
1 (
RE
) -
1Lo
ck 2
(B
R)
-2
Inp
ut1
(Y
E)
-3
Inp
ut2
(G
R)
-4
GN
D (
BK
) -
5E
xit
B (
OR
) -
6G
ND
(B
K)
-7
Pin
1
Pin
2Pin
3
Pin
6
Pin
7
11.3. Connect with One system/ Two Locks ** Use external DC Power adapter