T2ZK7F8 8 Door Kit with Fused Outputs Fully assembled kit includes: - Trove2 enclosure with TZ2 Altronix/ZKTeco backplane - One (1) eFlow104NB - Power Supply/Charger - One (1) ACM8 - Access Power Controller - One (1) VR6 - Voltage Regulator - One (1) PDS8 - Dual Input Fused Power Distribution Module T2ZK7F16 16 Door Kit with Fused Outputs Fully assembled kit includes: - Trove2 enclosure with TZ2 Altronix/ZKTeco backplane - One (1) eFlow104NB - Power Supply/Charger - Two (2) ACM8 - Access Power Controllers - One (1) VR6 - Voltage Regulator - One (1) PDS8 - Dual Input Fused Power Distribution Module All components of this Trove kit are UL Listed sub-assemblies. Please refer to the included corresponding Sub-Assembly Installation Guides for further information. Rev. TZK_041019 Installing Company: _________________________ Service Rep. Name: __________________________________________ Address: _________________________________________________________ Phone #: _________________________ All registered trademarks are property of their respective owners. Installation Guide More than just power.™ Access & Power Integration Altronix/ZKTeco Kits Models Include:
8

Installation Guide - Altronix

May 08, 2023

Download

Documents

Khang Minh
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: Installation Guide - Altronix

T2ZK7F88 Door Kit with Fused Outputs Fully assembled kit includes: - Trove2 enclosure with TZ2 Altronix/ZKTeco backplane - One (1) eFlow104NB - Power Supply/Charger - One (1) ACM8 - Access Power Controller - One (1) VR6 - Voltage Regulator - One (1) PDS8 - Dual Input Fused Power Distribution Module

T2ZK7F1616 Door Kit with Fused Outputs Fully assembled kit includes: - Trove2 enclosure with TZ2 Altronix/ZKTeco backplane - One (1) eFlow104NB - Power Supply/Charger - Two (2) ACM8 - Access Power Controllers - One (1) VR6 - Voltage Regulator - One (1) PDS8 - Dual Input Fused Power Distribution Module

All components of this Trove kit are UL Listed sub-assemblies.Please refer to the included corresponding Sub-Assembly Installation Guides for further information.

Rev. TZK_041019

Installing Company: _________________________ Service Rep. Name: __________________________________________

Address: _________________________________________________________ Phone #: _________________________

All registered trademarks are property of their respective owners.

Installation Guide

More than just power.™

Access & Power Integration

Altronix/ZKTeco Kits

Models Include:

Page 2: Installation Guide - Altronix

- 2 - Trove ZKTeco Kits Installation Guide

Overview:Altronix T2ZK7F8 and T2ZK7F16 Trove ZKTeco kits are pre-assembled and consist of Trove enclosures/backplanes with factory installed Altronix power supply/chargers and sub-assemblies. T2ZK7F8 accommodates up to two (2) ZKTeco modules for up to eight (8) doors in a single enclosure.T2ZK7F16 accommodates up to four (4) ZKTeco modules for up to sixteen (16) doors in a single enclosure.

Configuration Chart:

AltronixModel Number 12

0VAC

60H

zIn

put C

urre

nt (A

)Po

wer

Sup

ply

Boar

dIn

put F

use

Ratin

gPo

wer

Sup

ply

Boar

dBa

ttery

Fus

e Ra

ting Maximum Supply

Current for Main and Aux. Outputs on

Power Supply board and ACM8 Access Power Controllers’

outputs

Nominal DC Output Voltage

Fail-

Safe

/Fai

l-Sec

ure

or D

ry F

orm

“C”

Ou

tput

s

Addi

tiona

l Fus

ed

Outp

uts

ACM

8 Bo

ard

Inpu

t Fus

e Ra

ting

ACM

8 Bo

ard

Outp

ut F

use

Ratin

g

PDS8

Boa

rdIn

put F

use

Ratin

g

PDS8

Boa

rdOu

tput

Fus

e Ra

ting

[DC] [Aux]

Output Range (VDC)

Output Range (VDC)

T2ZK7F84.5 6.3A/

250V15A/32V

24VDC @ 9.7A20.17-26.4 20.28-26.4

88 10A/

250V2.5A/250V

10A/32V

3A/32VT2ZK7F16 24VDC @ 9.4A 16

Installation Instructions:Wiring methods shall be in accordance with the National Electrical Code/NFPA 70/ANSI, and with all local codes and authorities having jurisdiction. Product is intended for indoor use only. 1. Remove backplane from enclosure. Do not discard hardware.2. Mark and predrill holes in the wall to line up with the top two/three keyholes in the enclosure. Install two/three upper fasteners and screws in the wall with the screw heads protruding. Place the enclosure’s upper keyholes over the two/three upper screws; level and secure. Mark the position of the lower three holes. Remove the enclosure. Drill the lower holes and install the three fasteners. Place the enclosure’s upper keyholes over the two/three upper screws. Install the three lower screws and make sure to tighten all screws.3. Mount included UL Listed tamper switch (Altronix Model TS112 or equivalent) in desired location, opposite hinge. Slide the tamper switch bracket onto the edge of the enclosure approximately 2” from the right side (Fig. 1, pg. 2). Connect tamper switch wiring to the Access Control Panel input or the appropriate UL Listed reporting device. To activate alarm signal open the door of the enclosure.4. Mount ZKTeco modules to backplane, refer to pages 3 - 6.5. Refer to the eFlow Power Supply/Charger Installation Guide for eFlow104NB and corresponding Sub-Assembly Installation Guides for ACM8, PDS8 and VR6 for further installation instructions.

Hardware:

Fig. 1

Tamper Switch(included)

To Access Control Panel orUL Listed Reporting Device

Edge ofEnclosure

Enclosure

Nylon Spacer | 5/16” Pan Head Screw | Lock Nut

Page 3: Installation Guide - Altronix

Trove ZKTeco Kits Installation Guide - 3 -

T2ZK7F8: Configuration of ZKTeco inBio Modules:1. Fasten DIN Rail (provided by ZKTeco) to pem spacers, utilizing 5/16” pan head screws (included) (Fig. 2, pg. 3). 2. Mount ZKTeco modules to DIN Rail (refer to below chart for model number, Fig. 2, pg. 3).3. Fasten TZ2 backplane to Trove2 enclosure utilizing lock nuts (provided by Altronix).

ZKTeco Model Pem Mounting

inBio-160, inBio-160 Pro, inBio-260, inBio-260 Pro, inBio-460, inBio-460 Pro A

Fig. 2

– D

C

+–

BA

T +

L G N

OUTPUT 1 OUTPUT 2 OUTPUT 3 OUTPUT 4 OUTPUT 5 OUTPUT 6 OUTPUT 7 OUTPUT 8

NC C NO COM NC C NO COM NC C NO COM NC C NO COM NC C NO COM NC C NO COM NC C NO COM NC C NO COM

IN GND IN GND IN GND IN GNDIN GND IN GND IN GND IN GND1 2 3 4 5 6 7 8

INPUTTRIGGER

10A 250V

+IN

P-

T +

RE

T-N

O C

N

CFA

CP

INTE

RFA

CE

Pow

er

Con

trol

-

+

-

+

F1 F2 F3 F4 F5 F6 F7 F8

MAIN

TRG

FACP

1 2 3 41 2 3 4

O NO N

1 2 3 41 2 3 4

O NO N

+ INP1 --

DM1 + OFFIN1IN2

Out1

<1 o

ff 2 >

DM1 +

DM2 +DM2 +

Common (--- )

Common (--- )

+ INP2 --

IN2 F

use

IN1 Fuse

Common Power Outputs (NEG)

N

P

OUT1 OUT2 OUT3 OUT4 OUT5 OUT6 OUT7 OUT8

1 2 3 4 5 6 7 8

10

10

33

3 3 3 3 3 3Out2

<1 o

ff 2 >

Out3

<1 o

ff 2 >

Out4

<1 o

ff 2 >

Out5

<1 o

ff 2 >

Out6

<1 o

ff 2 >

Out7

<1 o

ff 2 >

Out8

<1 o

ff 2 >

A

A

A

A

Altronix - eFlow104NB

Altronix - ACM8

Altronix - PDS8

Altronix VR6 is mounted under PDS8

Page 4: Installation Guide - Altronix

- 4 - Trove ZKTeco Kits Installation Guide

T2ZK7F8: Configuration of ZKTeco C3 Modules:1. Fasten spacers (provided) to pems that match the hole pattern for ZKTeco boards. Refer to below chart for model number and Fig. 3, pg. 4. 2. Mount ZKTeco boards to spacers utilizing 5/16” pan head screws (included) (Fig. 3a, pg. 4).3. Fasten TZ2 backplane to Trove2 enclosure utilizing lock nuts (included).

ZKTeco Model Pem Mounting

C3-400, C3-400 Pro B

C3-100, C3-100 Pro, C3-200, C3-200 Pro C

Fig. 3

– D

C

+–

BA

T +

L G N

OUTPUT 1 OUTPUT 2 OUTPUT 3 OUTPUT 4 OUTPUT 5 OUTPUT 6 OUTPUT 7 OUTPUT 8

NC C NO COM NC C NO COM NC C NO COM NC C NO COM NC C NO COM NC C NO COM NC C NO COM NC C NO COM

IN GND IN GND IN GND IN GNDIN GND IN GND IN GND IN GND1 2 3 4 5 6 7 8

INPUTTRIGGER

10A 250V

+IN

P-

T +

RE

T-N

O C

N

CFA

CP

INTE

RFA

CE

Pow

er

Con

trol

-

+

-

+

F1 F2 F3 F4 F5 F6 F7 F8

MAIN

TRG

FACP

1 2 3 41 2 3 4

O NO N

1 2 3 41 2 3 4

O NO N

+ INP1 --

DM1 + OFFIN1IN2

Out1

<1 o

ff 2 >

DM1 +

DM2 +DM2 +

Common (--- )

Common (--- )

+ INP2 --

IN2 F

use

IN1 Fuse

Common Power Outputs (NEG)

N

P

OUT1 OUT2 OUT3 OUT4 OUT5 OUT6 OUT7 OUT8

1 2 3 4 5 6 7 8

10

10

33

3 3 3 3 3 3Out2

<1 o

ff 2 >

Out3

<1 o

ff 2 >

Out4

<1 o

ff 2 >

Out5

<1 o

ff 2 >

Out6

<1 o

ff 2 >

Out7

<1 o

ff 2 >

Out8

<1 o

ff 2 >

CB

CB

CB

CB

Altronix - eFlow104NB

Altronix - ACM8

Altronix - PDS8

Altronix VR6 is mounted under PDS8

Pem

Spacer

ZKTecoC3 100/200/400 BackplanePan Head

Screw

Fig. 3a

Page 5: Installation Guide - Altronix

Trove ZKTeco Kits Installation Guide - 5 -

T2ZK7F16: Configuration of ZKTeco inBio Modules:1. Fasten DIN Rail (provided by ZKTeco) to pem spacers, utilizing 5/16” pan head screws (included) (Fig. 4, pg. 5). 2. Mount ZKTeco modules to DIN Rail (refer to below chart for model number, Fig. 4, pg. 5).3. Fasten TZ2 backplane to Trove2 enclosure utilizing lock nuts (provided by Altronix).

ZKTeco Model Pem Mounting

inBio-160, inBio-160 Pro, inBio-260, inBio-260 Pro, inBio-460, inBio-460 Pro A

Fig. 4

– D

C

+–

BA

T +

L G N

OUTPUT 1 OUTPUT 2 OUTPUT 3 OUTPUT 4 OUTPUT 5 OUTPUT 6 OUTPUT 7 OUTPUT 8

NC C NO COM NC C NO COM NC C NO COM NC C NO COM NC C NO COM NC C NO COM NC C NO COM NC C NO COM

IN GND IN GND IN GND IN GNDIN GND IN GND IN GND IN GND1 2 3 4 5 6 7 8

INPUTTRIGGER

10A 250V

+IN

P-

T +

RE

T-N

O C

N

CFA

CP

INTE

RFA

CE

Pow

er

Con

trol

-

+

-

+

F1 F2 F3 F4 F5 F6 F7 F8

MAIN

TRG

FACP

1 2 3 41 2 3 4

O NO N

1 2 3 41 2 3 4

O NO N

OUTPUT 1 OUTPUT 2 OUTPUT 3 OUTPUT 4 OUTPUT 5 OUTPUT 6 OUTPUT 7 OUTPUT 8

NC C NO COM NC C NO COM NC C NO COM NC C NO COM NC C NO COM NC C NO COM NC C NO COM NC C NO COM

IN GND IN GND IN GND IN GNDIN GND IN GND IN GND IN GND1 2 3 4 5 6 7 8

INPUTTRIGGER

10A 250V

+IN

P-

T +

RE

T-N

O C

N

CFA

CP

INTE

RFA

CE

Pow

er

Con

trol

-

+

-

+

F1 F2 F3 F4 F5 F6 F7 F8

MAIN

TRG

FACP

1 2 3 41 2 3 4

O NO N

1 2 3 41 2 3 4

O NO N

+ INP1 --

DM1 + OFFIN1IN2

Out1

<1 o

ff 2 >

DM1 +

DM2 +DM2 +

Common (--- )

Common (--- )

+ INP2 --

IN2 F

use

IN1 Fuse

Common Power Outputs (NEG)

N

P

OUT1 OUT2 OUT3 OUT4 OUT5 OUT6 OUT7 OUT8

1 2 3 4 5 6 7 8

10

10

33

3 3 3 3 3 3Out2

<1 o

ff 2 >

Out3

<1 o

ff 2 >

Out4

<1 o

ff 2 >

Out5

<1 o

ff 2 >

Out6

<1 o

ff 2 >

Out7

<1 o

ff 2 >

Out8

<1 o

ff 2 >

A

A

A

A

Altronix - eFlow104NB

Altronix - ACM8

Altronix - ACM8

Altronix - PDS8

Altronix VR6 is mounted under PDS8

Page 6: Installation Guide - Altronix

- 6 - Trove ZKTeco Kits Installation Guide

T2ZK7F16: Configuration of ZKTeco C3 Modules:1. Fasten spacers (provided) to pems that match the hole pattern for ZKTeco boards. (refer to below chart for model number, Fig. 5, pg. 6). 2. Mount ZKTeco boards to spacers utilizing 5/16” pan head screws (included) (Fig. 5a, pg. 6).3. Fasten TZ2 backplane to Trove2 enclosure utilizing lock nuts (included).

ZKTeco Model Pem Mounting

C3-400, C3-400 Pro B

C3-100, C3-100 Pro, C3-200, C3-200 Pro C

Fig. 5

– D

C

+–

BA

T +

L G N

OUTPUT 1 OUTPUT 2 OUTPUT 3 OUTPUT 4 OUTPUT 5 OUTPUT 6 OUTPUT 7 OUTPUT 8

NC C NO COM NC C NO COM NC C NO COM NC C NO COM NC C NO COM NC C NO COM NC C NO COM NC C NO COM

IN GND IN GND IN GND IN GNDIN GND IN GND IN GND IN GND1 2 3 4 5 6 7 8

INPUTTRIGGER

10A 250V

+IN

P-

T +

RE

T-N

O C

N

CFA

CP

INTE

RFA

CE

Pow

er

Con

trol

-

+

-

+

F1 F2 F3 F4 F5 F6 F7 F8

MAIN

TRG

FACP

1 2 3 41 2 3 4

O NO N

1 2 3 41 2 3 4

O NO N

OUTPUT 1 OUTPUT 2 OUTPUT 3 OUTPUT 4 OUTPUT 5 OUTPUT 6 OUTPUT 7 OUTPUT 8

NC C NO COM NC C NO COM NC C NO COM NC C NO COM NC C NO COM NC C NO COM NC C NO COM NC C NO COM

IN GND IN GND IN GND IN GNDIN GND IN GND IN GND IN GND1 2 3 4 5 6 7 8

INPUTTRIGGER

10A 250V

+IN

P-

T +

RE

T-N

O C

N

CFA

CP

INTE

RFA

CE

Pow

er

Con

trol

-

+

-

+

F1 F2 F3 F4 F5 F6 F7 F8

MAIN

TRG

FACP

1 2 3 41 2 3 4

O NO N

1 2 3 41 2 3 4

O NO N

+ INP1 --

PWR1 + OFFIN1IN2

Out1

<1 o

ff 2 >

DM1 +

PWR2 +PWR2 +

COM ---

COM ---

+ INP2 --

IN2 F

use

IN1 Fuse

Common Power Outputs (NEG)

N

P

OUT1 OUT2 OUT3 OUT4 OUT5 OUT6 OUT7 OUT8

1 2 3 4 5 6 7 8

10

10

33

3 3 3 3 3 3Out2

<1 o

ff 2 >

Out3

<1 o

ff 2 >

Out4

<1 o

ff 2 >

Out5

<1 o

ff 2 >

Out6

<1 o

ff 2 >

Out7

<1 o

ff 2 >

Out8

<1 o

ff 2 >

CB

CB

CB

CB

Altronix - eFlow104NB

Altronix - ACM8

Altronix - ACM8

Altronix - PDS8

Altronix VR6 is mounted under PDS8

Pem

Spacer

ZKTecoC3 100/200/400 BackplanePan Head

Screw

Fig. 5a

Page 7: Installation Guide - Altronix

Trove ZKTeco Kits Installation Guide - 7 -

eFlow Power Supply/Chargers can be Controlled and Monitored while Reporting Power/Diagnostics from Anywhere over the Network...

LINQ2 Mounts Inside any Trove Enclosure

LINQ2 - Network Communication ModuleLINQ2 provides remote IP access to real-time data from eFlow power supply/chargers to help keep systems up and running at optimal levels. It facilitates fast and easy installation and set-up, minimizes system downtime, and eliminates unnecessary service calls, which helps reduce Total Cost of Ownership (TCO) - as well as creat-ing a new source of Recurring Monthly Revenue (RMR).

LINQ2

Features:- UL Listed in the U.S. and Canada.- Local or remote control of up to (2) two Altronix eFlow power output(s) via LAN and/or WAN.- Monitor real time diagnostics: DC output voltage, output current, AC & battery status/service, input trigger state change, output state change and unit temperature.- Access control and user managment: Restrict read/write, Restrict users to specific resources- Two (2) integral network controlled Form “C” Relays.- Three (3) programmable input triggers: Control relays and power supplies via external hardware sources.- Email and Windows Dashboard notifications- Event log tracks history.- Secure Socket Layer (SSL).- Programmable via USB or web browser - includes operating software and 6 ft. USB cable.

LINQ2 Module

Altronix eFlowPower Supply

Network Connection:Installation, Programmingand Monitoring

Page 8: Installation Guide - Altronix

- 8 - Trove ZKTeco Kits Installation Guide

6.75

” (17

1.5m

m)

8.25

” (20

9.5m

m)

8.00

” (20

3.2m

m)

2.00” (50.8mm)

2.00” (50.8mm)

1.25” (31.8mm)

1.25” (31.8mm)

5.25” (133.4mm) 5.25” (133.4mm)7.00” (177.8mm)

1.25” (31.8mm)6.25” (158.8mm) 19.80” (502.9mm)

1.00” (25.4mm)

27” (

685.

8mm

)

1.5”(38.1mm)

2.00” (50.8mm) 2.00” (50.8mm)3.5”(88.9mm) 3.5”(88.9mm)

21.50” (546.1mm)

5.25” (133.35mm) 5.25” (133.35mm)

6.25

” (15

8.8m

m)

1.25”(31.8mm)

0.85” (21.6mm)

0.5625” (14.3mm)

2.415” (61.3mm)

0.685” (17.4mm)

1.77”(45mm)

0.885” (22.5mm)

1.125” (28.3mm)Knockouts

2.00” (50.8mm) 2.00” (50.8mm)

Enclosure Dimensions (H x W x D):27.25” x 21.75” x 6.5” (692.2mm x 552.5mm x 165.1mm)

Altronix is not responsible for any typographical errors.–––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––140 58th Street, Brooklyn, New York 11220 USA | phone: 718-567-8181 | fax: 718-567-9056web site: www.altronix.com | e-mail: [email protected] | Lifetime WarrantyIITrove ZKTeco Kits J22U MEMBER