Top Banner
1 Installation Guide AB-QM DN 40-100 Heating Solutions VI.A7.E4.3T SMT/SI IP 54 AME 435 QM DN 40/50 DN 50 DN 65-100 Code No.: 003Z0695 + AME 435 QM + Installation / Montering / Einbau / Installation /Installatie / Installation / Asennus / Montaż / Uzstādīšana / Beépítés / Montaj / Монтаж / Instalace / 安装 / Vgradnja / Instalación / Montavimas DN 40/50 DN 50 DN 65-100
8

Installation Guide AB-QM DN 40-100 · AME 55 QM AB-QM DN 200/250 + AME 85 QM IP 54 IP 54 Installation / Montering / Einbau / Installation / Installatie / Installation / Asennus

Dec 28, 2018

Download

Documents

buikhue
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: Installation Guide AB-QM DN 40-100 · AME 55 QM AB-QM DN 200/250 + AME 85 QM IP 54 IP 54 Installation / Montering / Einbau / Installation / Installatie / Installation / Asennus /

1

Installation Guide

AB-QM DN 40-100

Heating Solutions VI.A7.E4.3T SMT/SI

IP 54

AME 435 QM

DN 40/50 DN 50

DN 65-100

Code No.: 003Z0695

+AME 435 QM

+

Installation / Montering / Einbau / Installation /Installatie / Installation / Asennus / Montaż / Uzstādīšana / Beépítés / Montaj / Монтаж / Instalace / 安装 / Vgradnja / Instalación / Montavimas

DN 40/50 DN 50 DN 65-100

Page 2: Installation Guide AB-QM DN 40-100 · AME 55 QM AB-QM DN 200/250 + AME 85 QM IP 54 IP 54 Installation / Montering / Einbau / Installation / Installatie / Installation / Asennus /

2

DN 40/50

50 mmMax. 25 Nm1 turn = 10%

Note: best before applying pressure

DN 65-100

42 mm

Max. 25 Nm1 turn = 10%

Setting / Indstilling / Einstellung / Réglage / Instelling / Inställning / Asettelu / Wykonywanie nastawy / Iestādījumi / Beállítás / Ayarlama / Настройка / Nastavení / 设定 / Nastavitev / Ajuste / Nustatymas

Resetting

Shut off / Afspærring / Absperrung / Fermeture / Afsluiten / Avstängning / Sulkuventtiili / Funkcja odcięcia / Aizvēršana / Elzárás / KAPAMA / Отключение /Uzavření / 关闭 / Zapiranje pretoka / Corte / Uždarymas

3 Nm

DN 40, DN 50 Δp max = 16 bar

DN 65-100Δp max = 16 bar

12 Nm

8 mm

DN 40-100

Max. 25 Nm1 turn = 10%

max

1 tu

rn

3 m

m

3 m

m

+

+

Installation Guide AB-QM DN 40-100

SMT/SI VI.A7.E4.3T Heating Solutions

Page 3: Installation Guide AB-QM DN 40-100 · AME 55 QM AB-QM DN 200/250 + AME 85 QM IP 54 IP 54 Installation / Montering / Einbau / Installation / Installatie / Installation / Asennus /

3

DN 40/50

DN 65-100

Locking / Låsning / Blockierung / Verrouillage / Vergrendelen / Låsning / Lukitseminen / Blokowanie nastawy / Noslēgšana / Korlátozás / Kilitle / Блокировка / Uzamykání / 锁定 / Blokiranje / Bloqueo / Blokavimas

Measuring / Måling / Messung / Mesure / Meten / Mätning / Mittaaminen / Wykonywanie pomiarów / Mērīšana / Mérés / Ölçüm / Измерение / Měření / 测量 / Merjenje / Medida / Matavimas

Pump optimization

Q ≠ const Q = const

Q

P1 - P330 kPa

DN 40/50

3 m

m

3 m

m

DN 65-100

Flow direction

Δp=p1-p3p1-p2

Δp=p1-p3

p1-p2

Installation Guide AB-QM DN 40-100

Heating Solutions VI.A7.E4.3T SMT/SI

Page 4: Installation Guide AB-QM DN 40-100 · AME 55 QM AB-QM DN 200/250 + AME 85 QM IP 54 IP 54 Installation / Montering / Einbau / Installation / Installatie / Installation / Asennus /

DN 80 L/h L/s GPM

40% 11200 3,11 49,3

45% 12600 3,50 55,5

50% 14000 3,89 61,6

55% 15400 4,23 67,8

60% 16800 4,67 74,0

65% 18200 5,10 80,1

70% 19600 5,44 86,3

75% 21000 5,83 92,5

80% 22400 6,22 98,6

85% 23800 6,61 104,8

90% 25200 7,00 111,0

95% 26600 7,39 117,1

100% 28000 7,78 123,3

Note: 1 turn = 10%

DN 100 L/h L/s GPM

40% 15200 4,22 66,9

45% 17100 4,75 75,3

50% 19000 5,28 83,7

55% 20900 5,81 92,0

60% 22800 6,33 100,4

65% 24700 6,86 108,8

70% 26600 7,39 117,1

75% 28500 7,92 125,5

80% 30400 8,44 133,8

85% 32300 8,97 142,2

90% 34200 9,50 150,6

95% 36100 10,03 158,9

100% 38000 10,56 167,3

Note: 1 turn = 10%

DN 65 L/h L/s GPM

40% 8000 2,22 35,2

45% 9000 2,50 39,6

50% 10000 2,78 44,0

55% 11000 3,06 48,4

60% 12000 3,33 52,8

65% 13000 3,61 57,2

70% 14000 3,89 61,6

75% 15000 4,17 66,0

80% 16000 4,44 70,4

85% 17000 4,72 74,9

90% 18000 5,00 79,3

95% 19000 5,28 83,7

100% 20000 5,56 88,1

Note: 1 turn = 10%

DN 40 L/h L/s GPM

20% 1500 0,416 6,6

25% 1875 0,520 8,3

30% 2250 0,625 9,9

35% 2625 0,729 11,6

40% 3000 0,833 13,2

45% 3375 0,937 14,9

50% 3750 1,041 16,5

55% 4125 1,145 18,2

60% 4500 1,250 19,8

65% 4875 1,354 21,5

70% 5250 1,458 23,1

75% 5625 1,562 24,8

80% 6000 1,666 26,4

85% 6375 1,770 28,1

90% 6750 1,875 29,7

95% 7125 1,979 31,4

100% 7500 2,083 33,0

Note: 1 turn = 10%

DN 50 L/h L/s GPM

40% 5000 1,386 22,0

45% 5625 1,562 24,8

50% 6250 1,736 27,5

55% 6875 1,909 30,3

60% 7500 2,083 33,0

65% 8125 2,256 35,8

70% 8750 2,430 38,50

75% 9375 2,604 41,3

80% 10000 2,777 44,0

85% 10625 2,951 46,8

90% 11250 3,125 49,5

95% 11875 3,298 52,3

100% 12500 3,472 55,0

Note: 1 turn = 10%

–10…120 °C Δpmax. = 400 kPa (4 bar)PN 16

Installation Guide AB-QM DN 40-100

73693790/VI.A7.E4.3T Produced by Danfoss A/S © 11/2014

Page 5: Installation Guide AB-QM DN 40-100 · AME 55 QM AB-QM DN 200/250 + AME 85 QM IP 54 IP 54 Installation / Montering / Einbau / Installation / Installatie / Installation / Asennus /

© Danfoss | 2016.02

AB-QM DN 125-250Operating Guide

VI.C6.C5.8Y | 1

Installation / Montering / Einbau / Installation / Installatie / Installation / Asennus / Montaż / Uzstādīšana / Beépítés / Montaj / Монтаж /Instalace / 安装 / Vgradnja / Instalación / Montavimas

AB-QM DN 125 AB-QM DN 150 AB-QM DN 200/250

+

+

AME 55 QM

AME 85 QM

Code No.: 003Z0696

Code No.: 003Z0697

DN 125/150 DN 200/250

Page 6: Installation Guide AB-QM DN 40-100 · AME 55 QM AB-QM DN 200/250 + AME 85 QM IP 54 IP 54 Installation / Montering / Einbau / Installation / Installatie / Installation / Asennus /

2 | © Danfoss| 2016.02 VI.C6.C5.8Y

AB-QM DN 125-250

AB-QM DN 125/150 +AME 55 QM

AB-QM DN 200/250 +AME 85 QM

IP 54 IP 54

Installation / Montering / Einbau / Installation / Installatie / Installation / Asennus / Montaż / Uzstādīšana / Beépítés / Montaj / Монтаж /Instalace / 安装 / Vgradnja / Instalación / Montavimas

Temp. −10 ... 120 °C Δpmax. = 600 kPa*PN 16

* In case AB-QM is used above 400 kPa differential pressure contact Danfoss design center to assure proper design.

Page 7: Installation Guide AB-QM DN 40-100 · AME 55 QM AB-QM DN 200/250 + AME 85 QM IP 54 IP 54 Installation / Montering / Einbau / Installation / Installatie / Installation / Asennus /

© Danfoss | 2016.02 | 3VI.C6.C5.8Y

AB-QM DN 125-250

Setting / Indstilling / Einstellung / Réglage / Instelling / Inställning / Asettelu / Wykonywanie nastawy / Iestādījumi / Beállítás /Ayarlama / Настройка / Nastavení / 设定 / Nastavitev / Ajuste / Nustatymas

Measuring / Måling / Messung / Mesure / Meten / Mätning / Mittaaminen / Wykonywanie pomiarów / Mērīšana / Mérés / Ölçüm /Измерение / Měření / 测量 / Merjenje / Medida / Matavimas

+–

Setting 60%

+

Note: 1 turn = 5.0 %

DN 125Flow High Flow

L/h L/s GPM L/h L/s GPM40% 36.000 10,00 158 44.000 12,22 19445% 40.500 11,25 178 49.500 13,75 21850% 45.000 22,50 188 55.000 15,28 24255% 49.500 13,75 218 60.500 16,81 26660% 54.000 15,00 238 66.000 18,33 29065% 58.500 16,25 257 71.500 19,86 31570% 63.000 17,50 277 77.000 21,39 33975% 67.500 18,75 297 82.500 22,92 36380% 72.000 20,00 317 88.000 24,44 38785% 76.500 21,25 337 93.500 25,97 41190% 81.000 22,50 356 99.000 27,50 43695% 85.500 23,75 376 104.500 29,03 460

100% 90.000 25,00 396 110.000 30,56 484105% 95.000 26,39 418 115.000 31,94 506110% 100.000 27,78 440 120.000 33,33 528

Note: 1 turn = 5,0%

DN 150Flow High Flow

L/h L/s GPM L/h L/s GPM40% 58.000 16,11 255 76.000 21,11 33445% 65.250 18,13 287 85.500 23,75 37650% 72.500 20,14 319 95.000 26,39 41855% 79.750 22,15 351 104.500 29,03 46060% 87.000 24,17 383 114.000 31,67 50265% 94.250 26,18 415 123.500 34,31 54370% 101.500 28,19 447 133.000 36,94 58575% 108.750 30,21 479 142.500 39,58 62780% 116.000 32,22 510 152.000 42,22 66985% 123.250 34,24 542 161.500 44,86 71190% 130.500 36,25 574 171.000 47,50 75295% 137.750 38,26 606 180.500 50,14 794

100% 145.000 40,28 638 190.000 52,78 836105% 152.500 42,36 671 209.500 58,19 922110% 160.000 44,44 704 229.000 63,61 1.008

Note: 1 turn = 5,0%

p1−p3

AB-QM DN 150

AB-QM DN 125

p1−p3

Page 8: Installation Guide AB-QM DN 40-100 · AME 55 QM AB-QM DN 200/250 + AME 85 QM IP 54 IP 54 Installation / Montering / Einbau / Installation / Installatie / Installation / Asennus /

VI.C6.C5.8Y 4 | © Danfoss | DHS-SRMT/SI | 2016.02

Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products already on order provided that such alterations can be made without subsequential changes being necessary eady agreed.All trademarks in this material are property of the respective companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved.

AB-QM DN 125-250

DN200Flow High Flow

L/h L/s GPM L/h L/s GPM

40% 80.000 22,22 352 108.000 30,00 475

45% 90.000 25,00 396 121.500 33,75 535

50% 100.000 27,78 440 135.000 37,50 594

55% 110.000 30,56 484 148.500 41,25 653

60% 120.000 33,33 528 162.000 45,00 713

65% 130.000 36,11 572 175.500 48,75 772

70% 140.000 38,89 616 189.000 52,50 832

75% 150.000 41,67 660 202.500 56,25 891

80% 160.000 44,44 704 216.000 60,00 950

85% 170.000 47,22 748 229.500 63,75 1010

90% 180.000 50,00 792 243.000 67,50 1069

95% 190.000 52,78 836 256.500 71,25 1129

100% 200.000 55,56 880 270.000 75,00 1188

105% 210.000 58,33 924 285.000 79,17 1254

110% 220.000 61,11 968 300.000 83,33 1320

Note: 1 turn = 5,0%

DN250Flow High Flow

L/h L/s GPM L/h L/s GPM

40% 120.000 33,33 528 148.000 41,11 651

45% 135.000 37,50 594 166.500 46,25 733

50% 150.000 41,67 660 185.000 51,39 814

55% 165.000 45,83 726 203.500 56,53 895

60% 180.000 50,00 792 222.000 61,67 977

65% 195.000 54,17 858 240.500 66,81 1058

70% 210.000 58,33 924 259.000 71,94 1140

75% 225.000 62,50 990 277.500 77,08 1221

80% 240.000 66,67 1056 296.000 82,22 1302

85% 255.000 70,83 1122 314.500 87,36 1384

90% 270.000 75,00 1188 333.000 92,50 1465

95% 285.000 79,17 1254 351.500 97,64 1547

100% 300.000 83,33 1320 370.000 102,78 1628

105% 315.000 87,50 1386 388.500 107,92 1709

110% 330.000 91,67 1452 407.000 113,06 1791

Note: 1 turn = 5,0% AB-QM DN 200/250

Measuring / Måling / Messung / Mesure / Meten / Mätning / Mittaaminen / Wykonywanie pomiarów / Mērīšana / Mérés / Ölçüm /Измерение / Měření / 测量 / Merjenje / Medida / Matavimas

p1−p3