PARUS – LED Grow Light Water Cooling System WATER COOLING SYSTEM Innovation Technology Innovative Technology
PARUS – LED Grow Light
Water Cooling System
WA
TE
R C
OO
LIN
G S
YS
TE
MIn
nova
tion
Tec
hnol
ogy
Innovative Technology
Easy InstallationCan be easily mounted to the previous/New modelEasily apply for green house, plant factory systemApplicable to low-cost and easy solution.
More Energy SavingEnergy saving more than ↓ 25%
More Intensity(PPFD)Light intensity more than ↑ 20%
More Life TimeLife time ↑ 50%~ longer
Applicable modelPGL-PFL SeriesPGL-SPOT SeriesPGL-BOX Series
WA
TE
R C
OO
LIN
G S
YS
TE
MIn
nova
tion
Tec
hnol
ogy
Water Cooling Standard
Standard Tb - 55°C
Water coolingTb - 22°C
Applicable model
RA SeriesPGL-PFL SeriesPGL-SPOT SeriesPGL-BOX Series
WATER COOLING SYSTEMInnovation Technology
Simple Design & UsingUsing Clean WaterNo condensation Use less water
Standard Tb 53°C
Water coolingTb 24°C
WATER COOLING SYSTEMTest Data
WA
TE
R C
OO
LIN
G S
YS
TE
MIn
nova
tion
Tec
hnol
ogy
Water Cooling LED Standard LED
Water Cooling LED Standard LED
WA
TE
R C
OO
LIN
G S
YS
TE
MIn
nova
tion
Tec
hnol
ogy
Problem of plant factory lightingA Plant factory has multi-layered growing systems, so many units of LED lights are installed in limited space. LED light generates heat when it works, If not handle this heat, it will reduce the efficiency and lifetime of LED lights. This heat also increases indoor temperature, high temperature disturb growth of plants, and cause additional energy cost for cooling.
Solution from PARUS (Patent technology)① PARUS plant factory uses the water cooling system which
gathers heat of LED lights and handle it effectively.② This heat can be emitted to outside of a plant factory in
summer time, can be used for indoor warming in winter time. The Water Cooling System can be controlled automatically and reduce energy cost of A/C.
PARUS Water Cooling System① increase lifetime of LED (30000 hr 100000 hr)② increase efficiency of LED (more than 25%)③ reduce energy cost (more than 25%)④ prevent plants from thermal shock and unhealthy growing⑤ use water as cooling media, make system safe and efficient
with low cost
110
100
90
80
70
65
60
55
50
010,000 20,000 30,000 40,000 50,000 60,000 70,000
METAL HALIDE
HIGH PRESSURE SODIUM
PLANT GROW LEDPARUS Water Cooling
% r
ated
lum
en/m
icro
mol
outp
utLa
mp
Rep
lace
men
t at
65%
/ E
OL
Gro
w L
amp
Rep
lace
men
t at
90%
/ P
AR
US
Hours of operation
Estimated Lamp LifeWater Cooling - Plants Grow Light
Commercial Lamp life cycle Plant Grow Lamp life cycle
METAL HALIDE : 900HRHIGH PRESSURE SODIUM : 1,000HRPLANT GROW LED : 45,000HR
METAL HALIDE : 5,000HRHIGH PRESSURE SODIUM : 18,000HRPLANT GROW LED : 82,000HR
Lamp Replacement at 65% / EOL Grow Lamp Replacement at 90%
WA
TE
R C
OO
LIN
G S
YS
TE
MIn
nova
tion
Tec
hnol
ogy
FLUORESCENT
STANDATD LED
Refle
ctiv
e Lig
ht O
utpu
t
200%
150%
100%
50%
0%-40 -20 0 20 40 60 80 100 120
Junction Temperature °C
25°C Rating Temperature
AmberRed
Green
White
Blue
Typical Application Temperature
Water CoolingLED Heat sink Effect
* Source : DOE (U.S. Department of Energy)
50%
PARUSWaterCooling
STD
WA
TE
R C
OO
LIN
G S
YS
TE
MIn
nova
tion
Tec
hnol
ogy
PARUS temperature of LED Water Cooling (Tc ~24°C = Tj35 ~45°C) General LED lamp life: 30,000 hours, PARUS LED lamp life: over 100,000 hours
Temperature LED Life Time Table
Water Cooling LED
WA
TE
R C
OO
LIN
G S
YS
TE
MIn
nova
tion
Tec
hnol
ogy
Power Conversion for "White" Light Sources
Incandescent Fluorescent Metal Halide LEDVisible Light 8% 21% 27% 30%
IR 73% 37% 17% 0%UV 0% 0% 19% 0%
Heat(Conduction+Convection) 19% 42% 37% 70%
Total 100% 100% 100% 100%
Total Heat(IR+Conduction+Convection) 92% 79% 54% 70%
* Source : DOE (U.S. Department of Energy)
사용 조명별 에너지 사용 전환율 및 발생 열 - 참고자료
0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100%
Incandesc…
Fluorescent
Metal…
LED Light
Light
Light
Light
Heat
HeatHeat - IR
Heat - IR
Heat - IR
Heat
Heat
UV
WA
TE
R C
OO
LIN
G S
YS
TE
MIn
nova
tion
Tec
hnol
ogy
Plant factory lightGrowing bed
(in 1ha)
Power consumption
(per bed)
Powerconsumption
(whole)
Heatgeneration Heat loss
LED 34,500 bed 160 watt 5,520,000 watt 3,864,000 watt 70%
Fluorescent 34,500 bed 320 watt 11,040,000 watt 8,721,600 watt 79%
Heat generation of LED light of 1ha plant factory 3,864KW / hr
It needs 4,000KW/hr of energy for using A/C to cool this heat.
The calculation of power consumption is based on 1,200mm x 600mm of growing bed and 250umol m-2 s-1(PPFD) of light intensity.
Energy cost reduction - more than 25%
Energy Cost발생된 열을 식히기 위한 별도의 에너지 비용 발생
WA
TE
R C
OO
LIN
G S
YS
TE
MIn
nova
tion
Tec
hnol
ogy
Energy consumption of plant factory lighting
LED Lighting and Water Cooling System식물공장 사용조명의 에너지 소모 비교
WA
TE
R C
OO
LIN
G S
YS
TE
MIn
nova
tion
Tec
hnol
ogy
Energy cost of a Plant factory ; 300m2 (1 year)
Fluorescent LEDPARUS LED
(Patent technology)Note
Power consumption 737,280 KWatt 368,640 KWatt 368,640 KWatt 1200x600 of growing bed x 400pcs
(converted into) Light 154,829 KWatt 110,592 KWatt 110,592 KWatt 250umol m-2 s-1 (green vegetable basis)
(converted into) Heat 582,451 KWatt 258,048 KWatt 258,048 KWatt Thermal energy
Energy for cooling heat 582,451 KWatt 258,048 KWatt 8,000 KWattEnergy for using A/C to cool indoor airA/C energy efficiency 33% (grade 1)
Total energy 1,319,731 KWatt 626,688 KWatt 376,640 KWatt
Energy cost 131,973 USD 62,669 USD 37,664 USD
CO2 emission 559,566 Kg 265,716 Kg 159,695 Kg
Calculation base : - Power consumption(input energy) : 16 hours lighting per day (all year round), 400pcs of growing beds (growing bed 1200mm x 600mm)- Energy converted into light for growing : PPFD 250umol m-2 s-1- Energy converted into heat : heat loss of the input energy- Energy for cooling heat : additional energy to cool heat which LED generates
Fluorescent, general LED The heat radiation of LED increases indoor temperature, so additional energy for cooling (A/C) is needed tomaintain proper indoor temp.
PARUS LED light Applying the patent technology, PARUS Water Cooling System handles heat of LED effectively, reuses heat to warmindoor air in winter, emits heat in summer to reduce energy cost.
Applicable case : Plant Factory systemWater cooling system
WA
TE
R C
OO
LIN
G S
YS
TE
MIn
nova
tion
Tec
hnol
ogy
WA
TE
R C
OO
LIN
G S
YS
TE
MIn
nova
tion
Tec
hnol
ogy
Water Pump
Water Filter
PFL & RBC
Water Cooling Heat Sink
Chiller
Applicable case : Plant Factory system, Green HouseWater cooling system
Applicable case : Green HouseWater cooling system
WA
TE
R C
OO
LIN
G S
YS
TE
MIn
nova
tion
Tec
hnol
ogy
Warm WaterCool Water
Water Cooling Pump SystemPump Control & Filter FittingSmall ~ big pump model SeriesWater Pipe 6mm,10mm, 12mm, 18mm, 25mm Automatic Water flow control
Test DataWater Cooling System
Water Cooling Test (PFL 1200 2line)
Dim Level
Wattage PPFD-µmolWater STD Water STD
0 0 0 0 01 33 40 12 162 54 75 30 373 92 121 55 574 127 158 76 715 160 196 93 806 175 231 110 877 208 238 111 878 217 246 112 889 221 255 114 89
10 230 258 117 8911 240 269 118 8912 252 274 120 9013 257 286 122 9014 264 292 123 9015 276 302 125 9016 286 314 126 9117 297 320 127 9018 311 331 128 9119 322 342 129 9220 333 350 129 92
Test conditionModel : PGL-PFL 1200 2line 200WattEnvironment Temp : 21°CWater Temp : 20.5°CPPFD : @800mm
Max testWater cooling Tb(25°C) 333watt,135µmol
STD cooling Tb(77°C) 350watt, 92µmol
Wat
er C
oolin
gTe
st D
ata
PPFD
Water Cooling Test (PFL 1200 2line)
Dim Level
Wattage PPFD-µmolWater STD Water STD
1 (19.53v) 20 26 12 202 (20.08v) 39 47 58 753 (22.07v) 63 73 124 1404 (23.16v) 90 107 183 2045 (23.97v) 114 129 235 2436 (24.89v) 142 158 292 2927 (25.03v) 147 163 301 2998 (25.17v) 152 170 310 3089 (25.35v) 157 174 319 316
10 (25.50v) 163 179 330 32311 (25.65v) 171 185 341 33212 (25.83v) 175 192 350 34013 (25.97v) 184 197 361 34914 (26.19v) 188 206 372 35915 (26.35v) 189 206 373 36016 (26.60v) 196 38317 (26.7v) 205 396
18 (26.94v) 211 40519 (27.20v) 221 41820 (27.43v) 230 433
Test conditionModel : PGL-PFL 1200 1line 80watt x 2pcs Environment Temp : 21°CWater Temp : 20.5°CPPFD : @260mm
Max test (Dimming Level 15)Water cooling Tb(22.5°C) 189watt, 373µmol
STD cooling Tb(52.0°C) 206watt, 360µmol
Wat
er C
oolin
gTe
st D
ata
PPFD
Wat
er C
oolin
gTe
st D
ata
Water Temp PPFD Wattage
18°C 290 675
20°C 280 672
22°C 279 670
24°C 275 674
26°C 273 675
28°C 269 675
30°C 267 675
32°C 264 672
34°C 261 670
36°C 259 670
38°C 257 668
40°C 250 666
42°C 248 666
44°C 245 665
46°C 241 663
PPFD@1meter, no lens, Environment temp 25°C
Water Cooling COB 700 test data
Test conditionModel : RA series (RA-700)Environment Temp : 25°CWater Temp : 18~46°CPPFD : @1000mm, no lens
Max testWater cooling Tb(18°C) 675watt,290µmolWater cooling Tb(46°C) 663watt,241µmol
Wat
er C
oolin
gTe
st D
ata
WattWater Cooling
PPFDActive Cooling
PPFD%
1 15 14 8 43
2 50 38 29 24
3 100 72 58 19
4 150 99 80 19
5 200 127 100 21
6 250 150 120 20
7 300 172 135 22
8 350 194 147 24
9 400 209 156 25
10 450 227 163 28
11 500 241 168 30
12 550 253 176 30
13 600 264 176 33
14 650 273 178 35
15 680 285 179 37
PPFD@1 meter, no lens, Environment temp 25°C
Water cooling Temp 20°C,Active Cooling environment Temp 25°C(Metal-PCB 65°C, Tj 75°C)
Test conditionModel : RA series (RA-700)Environment Temp : 25°CWater Temp : 20°CPPFD : @1000mm, no lens
Max testWater cooling Tb(20°C) 680watt,285µmolActive cooling Tb(65°C) 680watt,179µmol