- Hot dip galvanized to AS/NZS 4680- 1999 - Complies with durability ratings up to R3 of AS/NZS 2699.3 - Cost savings compared to conventional arch bars - Hot dip galvanized to AS/NZS 4680- 1999 - Complies with durability ratings up to R3 of AS/NZS 2699.3 - Cost savings compared to conventional arch bars INGAL BUILDING S YSTEMS INGAL BUILDING SYSTEMS WWW INDGALVCOM AU W W W. I N D GA LV. C O M . AU THE LIGHTWEIGHT LINTEL THAT GIVES MAXIMUM PERFORMANCE. LINTELS DEVELOPED IN AUSTRALIA FOR SUPPORTING BRICKWORK IN AUSTRALIAN HOMES.
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
- Hot dip galvanized to AS/NZS 4680-1999- Complies with durability ratings up to R3 of AS/NZS 2699.3- Cost savings compared to conventional arch bars
- Hot dip galvanized to AS/NZS 4680-1999- Complies with durability ratings up to R3 of AS/NZS 2699.3- Cost savings compared to conventional arch bars
INGALBUILDING SYSTEMSINGALBUILDING SYSTEMSWWW INDGALV COM AUWWW.INDGALV.COM.AU
THE LIGHTWEIGHT LINTEL THAT GIVES
MAXIMUM PERFORMANCE.
LINTELS
DEVELOPED IN AUSTRALIA FOR SUPPORTING
BRICKWORK IN AUSTRALIAN HOMES.
TOLLFREE: 1800 701 555
The required INGAL Lintel length is listed maximum clear INGAL Lintel span plus twice the required end bearing which for structural (load bearing) brickwork is typically:
NOTE: The information in this publication is provided for use as a GUIDE ONLY. Except to the extent that responsibility cannot lawfully be excluded, Industrial Galvanizers Corporation Pty Ltd (”IGC”) does not accept responsibility for any loss or damage of any kind however arising in connection with the selection and use of INGAL Lintel. IGC recommends that professional advice be sought in the selection and use of INGAL Lintel.
* 100mm x 100mm INGAL Lintel ~ All spans up to 1800mm = Clear Span + 200mm* 150mm x 100mm INGAL Lintel ~ All spans = Clear Span + 300m
N.B. Where the brickwork does not comply with the ‘Brickwork Code’, the bearing capacity of the brickwork should be checked by a Structural Engineer.
INGAL Lintels Length (metres)
TYPE ABrick veneer construc-tions with non load-bearing brickwork. Roof structure supported on timber frame
TYPE BLightweight metal roof and ceiling supported on single skin brickwork
TYPE CDouble Cavity brick roof supported uniformly on both skins of brickwork
TYPE DTiled roof with truss/rafter construction supported on a single skin of brickwork
TYPE ELower floor of two storey construction
TYPE OF CONSTRUCTION RAFTER/TRUSS SPAN IN METRES
The above table is provided as a guide for a range of loading applications. Many more loading applications are possible and a comprehensive stock range is manufactured for your selection.