Top Banner
Infrastructure Case Study
39

Infrastructure Case Study - Iowa State Universityhome.engineering.iastate.edu/~jdm/wesep594/MattColeAlliant.pdf · Overview of Balance of Plant ... Dynamic Volt-Amp Reactive ... Superimposed

Jul 14, 2018

Download

Documents

doanthien
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: Infrastructure Case Study - Iowa State Universityhome.engineering.iastate.edu/~jdm/wesep594/MattColeAlliant.pdf · Overview of Balance of Plant ... Dynamic Volt-Amp Reactive ... Superimposed

Infrastructure Case Study

Page 2: Infrastructure Case Study - Iowa State Universityhome.engineering.iastate.edu/~jdm/wesep594/MattColeAlliant.pdf · Overview of Balance of Plant ... Dynamic Volt-Amp Reactive ... Superimposed

Agenda

Alliant Energy Portfolio Mix

Wind Generation Across the United States

Wind Turbine Generator (WTG) Operation

Overview of Balance of Plant (BOP) Equipment

Wind Development & Construction Activities

Infrastructure Challenges / Case Study

Page 3: Infrastructure Case Study - Iowa State Universityhome.engineering.iastate.edu/~jdm/wesep594/MattColeAlliant.pdf · Overview of Balance of Plant ... Dynamic Volt-Amp Reactive ... Superimposed

Alliant Energy - LNTWe are an investor owned energy-services provider:

IPL – Interstate Power & Light Co

WPL – Wisconsin Power & Light Co

Headquartered in Madison, WI

General Offices in Cedar Rapids & Dubuque, IA

~ 4000 Employees

Page 4: Infrastructure Case Study - Iowa State Universityhome.engineering.iastate.edu/~jdm/wesep594/MattColeAlliant.pdf · Overview of Balance of Plant ... Dynamic Volt-Amp Reactive ... Superimposed

Alliant Energy – Service Territory

Alliant Energy serves

over 1,000 cities & towns

Customers:

> 950,000 electric

> 420,000 natural gas

Page 5: Infrastructure Case Study - Iowa State Universityhome.engineering.iastate.edu/~jdm/wesep594/MattColeAlliant.pdf · Overview of Balance of Plant ... Dynamic Volt-Amp Reactive ... Superimposed

Energy Portfolio2014

Page 6: Infrastructure Case Study - Iowa State Universityhome.engineering.iastate.edu/~jdm/wesep594/MattColeAlliant.pdf · Overview of Balance of Plant ... Dynamic Volt-Amp Reactive ... Superimposed

Source: AWEA 2016

Page 7: Infrastructure Case Study - Iowa State Universityhome.engineering.iastate.edu/~jdm/wesep594/MattColeAlliant.pdf · Overview of Balance of Plant ... Dynamic Volt-Amp Reactive ... Superimposed

Graph Source: AWEA Q4 2015 Market Report

Page 8: Infrastructure Case Study - Iowa State Universityhome.engineering.iastate.edu/~jdm/wesep594/MattColeAlliant.pdf · Overview of Balance of Plant ... Dynamic Volt-Amp Reactive ... Superimposed

Wind Generation Benefits

Benefit to customers, our communities and the state

Wind turbines generate clean, cost-effective energy for customers

Create tax revenue for communities, and bring construction jobs and economic growth to the state.

Wind Technician – Fastest growing profession in the U.S.

Low Cost Energy

Renewable Energy Tax Credits = Direct Benefit to the Customer

Zero Fuel Cost

“Wind Farmers” – Economic Support to Rural Communities

Turbine & Miscellaneous Easement Payments

Page 9: Infrastructure Case Study - Iowa State Universityhome.engineering.iastate.edu/~jdm/wesep594/MattColeAlliant.pdf · Overview of Balance of Plant ... Dynamic Volt-Amp Reactive ... Superimposed

Wind Generation Portfolio

344 Vestas V82 Turbines 1.65 MW Generator Rating

568 MW Fleet

Cedar Ridge – Eden, WI

41 Turbines / 68 MW

Bent Tree – Hartland, MN

122 Turbines / 201 MW

Whispering Willow – Iowa Falls

121 Turbines / 200 MW

Franklin County – Iowa Falls

60 Turbines / 99 MW

Page 10: Infrastructure Case Study - Iowa State Universityhome.engineering.iastate.edu/~jdm/wesep594/MattColeAlliant.pdf · Overview of Balance of Plant ... Dynamic Volt-Amp Reactive ... Superimposed

Wind Turbine Generator - WTG

1. Heat Exchanger

2. Generator

3. Nacelle Controller

4. Anemometer Wind Vanes

5. High Speed Coupling

6. Mechanical Brake

7. Gearbox

8. Main Shaft

9. Yaw Motor & Planetary

10.Tower Damper

11.Bed Plate Frame

12.Main Bearing

13.Hub

14.Pitch System

15.Blade

Page 11: Infrastructure Case Study - Iowa State Universityhome.engineering.iastate.edu/~jdm/wesep594/MattColeAlliant.pdf · Overview of Balance of Plant ... Dynamic Volt-Amp Reactive ... Superimposed

Additional WTG Components

Page 12: Infrastructure Case Study - Iowa State Universityhome.engineering.iastate.edu/~jdm/wesep594/MattColeAlliant.pdf · Overview of Balance of Plant ... Dynamic Volt-Amp Reactive ... Superimposed

Vestas V82 Stats Power Output 1.65MW

Hub Height 265 feet

Top of blade travel 400 feet

Blade length 131 feet

Blade weight 15,000 lbs.

Nacelle weight 104,000 lbs.

Nacelle size Class A Motorhome

Foundations 515 yards of concrete

57 Cement Truck Loads per Turbine

7,000 Cement Truck Loads Total Project

45’ X 45’ X 8’ Foundation

Page 13: Infrastructure Case Study - Iowa State Universityhome.engineering.iastate.edu/~jdm/wesep594/MattColeAlliant.pdf · Overview of Balance of Plant ... Dynamic Volt-Amp Reactive ... Superimposed

Turbine Performance Stats

Cut in speed 8 mph

Max Output 25 mph

Cut out 45 mph

Rotor RPM 14 rpm

Tip speed 138 mph

Page 14: Infrastructure Case Study - Iowa State Universityhome.engineering.iastate.edu/~jdm/wesep594/MattColeAlliant.pdf · Overview of Balance of Plant ... Dynamic Volt-Amp Reactive ... Superimposed

Balance of Plant - BOP

Page 15: Infrastructure Case Study - Iowa State Universityhome.engineering.iastate.edu/~jdm/wesep594/MattColeAlliant.pdf · Overview of Balance of Plant ... Dynamic Volt-Amp Reactive ... Superimposed

Wind Development

Meteorological Data

Infrastructure Consideration

Road Access, Grid Location

Land Rights

Easements

WTG, Roads, Collector

Regulatory Approvals

Generator Interconnection

Geotechnical Analysis

Micro-Siting

Setbacks

Page 16: Infrastructure Case Study - Iowa State Universityhome.engineering.iastate.edu/~jdm/wesep594/MattColeAlliant.pdf · Overview of Balance of Plant ... Dynamic Volt-Amp Reactive ... Superimposed

Geographic Information System & Micro-Siting

Page 17: Infrastructure Case Study - Iowa State Universityhome.engineering.iastate.edu/~jdm/wesep594/MattColeAlliant.pdf · Overview of Balance of Plant ... Dynamic Volt-Amp Reactive ... Superimposed

Turbine Layout

Page 18: Infrastructure Case Study - Iowa State Universityhome.engineering.iastate.edu/~jdm/wesep594/MattColeAlliant.pdf · Overview of Balance of Plant ... Dynamic Volt-Amp Reactive ... Superimposed

Access Roads

16 feet wide permanent

35 feet wide for cranes

Page 19: Infrastructure Case Study - Iowa State Universityhome.engineering.iastate.edu/~jdm/wesep594/MattColeAlliant.pdf · Overview of Balance of Plant ... Dynamic Volt-Amp Reactive ... Superimposed

Tower, Nacelle, Blade

Page 20: Infrastructure Case Study - Iowa State Universityhome.engineering.iastate.edu/~jdm/wesep594/MattColeAlliant.pdf · Overview of Balance of Plant ... Dynamic Volt-Amp Reactive ... Superimposed

Construction updateConstruction Overview

Page 21: Infrastructure Case Study - Iowa State Universityhome.engineering.iastate.edu/~jdm/wesep594/MattColeAlliant.pdf · Overview of Balance of Plant ... Dynamic Volt-Amp Reactive ... Superimposed

Geotechnical – Foundation Work

Page 22: Infrastructure Case Study - Iowa State Universityhome.engineering.iastate.edu/~jdm/wesep594/MattColeAlliant.pdf · Overview of Balance of Plant ... Dynamic Volt-Amp Reactive ... Superimposed

Completed Foundation

Page 23: Infrastructure Case Study - Iowa State Universityhome.engineering.iastate.edu/~jdm/wesep594/MattColeAlliant.pdf · Overview of Balance of Plant ... Dynamic Volt-Amp Reactive ... Superimposed

Tower Assembly

Page 24: Infrastructure Case Study - Iowa State Universityhome.engineering.iastate.edu/~jdm/wesep594/MattColeAlliant.pdf · Overview of Balance of Plant ... Dynamic Volt-Amp Reactive ... Superimposed

“Flying the Rotor”

Page 25: Infrastructure Case Study - Iowa State Universityhome.engineering.iastate.edu/~jdm/wesep594/MattColeAlliant.pdf · Overview of Balance of Plant ... Dynamic Volt-Amp Reactive ... Superimposed

Installation of Collector Lines

Page 26: Infrastructure Case Study - Iowa State Universityhome.engineering.iastate.edu/~jdm/wesep594/MattColeAlliant.pdf · Overview of Balance of Plant ... Dynamic Volt-Amp Reactive ... Superimposed

Substation

Receives 34.5kV Power generated by the WTG

Main Power Transformer / GSU (Generator Step Up) steps up the power to 161kV for interconnection to the transmission system

Reactive Power (VAR) Control Capacitor Banks Dynamic Volt-Amp Reactive

Control (D-VAR)

Page 27: Infrastructure Case Study - Iowa State Universityhome.engineering.iastate.edu/~jdm/wesep594/MattColeAlliant.pdf · Overview of Balance of Plant ... Dynamic Volt-Amp Reactive ... Superimposed

Infrastructure Challenges / Case Study Rural Areas

Siting Turbine Rating / Size / FAA Ceiling

Project Cost Cap Pressure Road Construction

Distribution / Transmission Build out to get to the Grid

Transmission Constraints / Congestion Localized, Network, Time of Year Challenges

Transmission Upgrades

MVP – Multi Value Projects

Voltage and Frequency Control

Limiting Component / Repowering / Recycling / Cost Reduction

Page 28: Infrastructure Case Study - Iowa State Universityhome.engineering.iastate.edu/~jdm/wesep594/MattColeAlliant.pdf · Overview of Balance of Plant ... Dynamic Volt-Amp Reactive ... Superimposed

Questions

Page 29: Infrastructure Case Study - Iowa State Universityhome.engineering.iastate.edu/~jdm/wesep594/MattColeAlliant.pdf · Overview of Balance of Plant ... Dynamic Volt-Amp Reactive ... Superimposed

Appendix

Page 30: Infrastructure Case Study - Iowa State Universityhome.engineering.iastate.edu/~jdm/wesep594/MattColeAlliant.pdf · Overview of Balance of Plant ... Dynamic Volt-Amp Reactive ... Superimposed

A Leader in Renewable Energy

Page 31: Infrastructure Case Study - Iowa State Universityhome.engineering.iastate.edu/~jdm/wesep594/MattColeAlliant.pdf · Overview of Balance of Plant ... Dynamic Volt-Amp Reactive ... Superimposed

Cedar Ridge Wind Farm

• 41 turbines - Vestas V-82

• 68 Megawatts

• 4th largest wind farm in Wisconsin

• Displaces approximately 75 rail cars of coal per month

• $180M capital investment

Page 32: Infrastructure Case Study - Iowa State Universityhome.engineering.iastate.edu/~jdm/wesep594/MattColeAlliant.pdf · Overview of Balance of Plant ... Dynamic Volt-Amp Reactive ... Superimposed

Bent Tree Wind Farm

• 122 turbines -Vestas V-82

• 201 Megawatts

• 5th Largest Wind Farm in MN

• Displaces approximately 225 rail

cars of coal per month.

• $440M capital investment

Page 33: Infrastructure Case Study - Iowa State Universityhome.engineering.iastate.edu/~jdm/wesep594/MattColeAlliant.pdf · Overview of Balance of Plant ... Dynamic Volt-Amp Reactive ... Superimposed

Whispering Willow East

121 turbines -Vestas V-82

200 Megawatts

Displaces approximately 225 Rail Cars

of coal per month

$460M capital investment

Page 34: Infrastructure Case Study - Iowa State Universityhome.engineering.iastate.edu/~jdm/wesep594/MattColeAlliant.pdf · Overview of Balance of Plant ... Dynamic Volt-Amp Reactive ... Superimposed

How Big is a Vestas V82 Turbine?

Vestas V82 – 80M Turbine

Superimposed on a Boeing

747 jumbo jet

80 m.

59.6 m.

Page 35: Infrastructure Case Study - Iowa State Universityhome.engineering.iastate.edu/~jdm/wesep594/MattColeAlliant.pdf · Overview of Balance of Plant ... Dynamic Volt-Amp Reactive ... Superimposed

35

Page 36: Infrastructure Case Study - Iowa State Universityhome.engineering.iastate.edu/~jdm/wesep594/MattColeAlliant.pdf · Overview of Balance of Plant ... Dynamic Volt-Amp Reactive ... Superimposed

Dimensions

Page 37: Infrastructure Case Study - Iowa State Universityhome.engineering.iastate.edu/~jdm/wesep594/MattColeAlliant.pdf · Overview of Balance of Plant ... Dynamic Volt-Amp Reactive ... Superimposed

How much Power?

Each Turbine produces 2,200 Horsepower

at 25 mph wind speed

Page 38: Infrastructure Case Study - Iowa State Universityhome.engineering.iastate.edu/~jdm/wesep594/MattColeAlliant.pdf · Overview of Balance of Plant ... Dynamic Volt-Amp Reactive ... Superimposed

Wind Turbine Generator Maintenance Routine Preventative Maintenance Services

Change filters, Greasing & Lubrication, Oil Changes

Torque Bolts

Inspections

Breakdown Repair

Troubleshoot Systems & Restart Turbines

Corrective Maintenance – Replace Parts

Underground Electrical System / Substation

Major Component Repair / Replacement

Main Bearings, Gear Boxes, Generators

Page 39: Infrastructure Case Study - Iowa State Universityhome.engineering.iastate.edu/~jdm/wesep594/MattColeAlliant.pdf · Overview of Balance of Plant ... Dynamic Volt-Amp Reactive ... Superimposed

Wind Turbine Generator Vs. Windmill

Windmills have flat blades which convert wind energy directly into mechanical energy for tasks such as milling grain or pumping water.

Wind Turbines have blades shaped like a wing which capture energy and convert it to electricity.

A Windmill can capture about 5% of the wind’s energy whereas a Wind Turbine captures and converts about 40% of the wind’s energy.