Page 1: Industrial-Thermometer

Industrial-Thermometer

Page 2: Industrial-Thermometer
Page 3: Industrial-Thermometer

IndexAccording to Types

Page 4: Industrial-Thermometer

Industrial ThermometersDetails of Design

CasingsAluminum, V-shaped, completely pol-ished, gold-colored anodized (or silver-colored upon request). Numerals ofreading scale printed on the right side.Printing black-colored for easy readability.Adjustable to any desired viewing positionand locked by brass nut, spanner size 22mm. Angle thermometers (90 degrees)have a grooved adapter piece with setscrew. Advantage: When mounting thethermometer, it is not necessary to turnthe casing.

Glass Inserts (Capillaries)Capillary tube of solid glass, bar-shaped,prismatic (optic enlargement of the col-umn), diameter approx. 6mm, oval open-ing, with yellow background for mercuryand white background for blue fluid col-umn. Calibration is deeply burnt, in black,thus being absolutely resistant. The maingraduations, which correspond with theprinting on the casing, are especiallyclearly outlined.

Capillary FluidFor standard executions from -60° to+200° C, blue fluid and red fluid, respecti-vely, for -60° C (code "Fu"). For tempera-tures of more than +200° C, only mercurycolumns (code "Hg") are possible. Uponrequest, thermometers can be deliveredwith mercury filling from -30° C onwards.

Immersion Tubes (Pockets)As a standard, manufactured of brass(code "Ms") for temperatures up to 300°C, for temperatures of more than 300° Cmade of steel (Code "St"). Seawaterresistant alloys are available upon request(special alloy SoMs 59, SoMs 76 or"CuNiSOFe"). For corrosive alkalis oracids, material 1.4571 (stainless steel) orother resistant kinds of steel are available.With immersion tube type "B", diameter is10 mm, thickness 1 mm.

AccuracyAbout 1 % of maximum scale value, forthermometers with mercury column. Theaccuracy of thermometers with an alco-holic fluid meets DIN 16 195 requirementsand, consequently, corresponds with therequirements for local readingthermometers.

Page 5: Industrial-Thermometer

SIKA ThermometersCasing 200 x 36 mm • gold- colored anodizedDIN 1 6 1 8 9 A, B, B1DIN 1 6 1 9 0 S , S 1DIN 1 6 1 9 1 B, B1

Immersion tubes of all right-angled thermometers are manufactured with a groovedadapter piece on top, which is installed in the casing and kept in its place by a set screw.Advantage: Immersion tube can be installed independently of thermometer casing. Noturning of thermometer casing is necessary on installation.

1) Bdr: Special execution of angle-type thermometer: After installation, casing can be turnedby 360° in any direct ion. See page 9 for descr ipt ion and i l lustrat ion.

Page 6: Industrial-Thermometer

SIKA ThermometersCasing 150x36mm • gold- colored anodizedDIN 16185BDIN 16186S

Immersion tubes of all right-angled thermometers are manufactured with a grooved adapterpiece on top, which is installed in the casing and kept in its place by a set screw. Advantage:Immersion tube can be installed independently of thermometer casing. No turning ofthermometer casing is necessary on installation.

1) Bdr: Special execution of angle-type thermometer: After installation, casing can be turnedby 360° in any direction. See page 9 for description and illustration.

Page 7: Industrial-Thermometer

SIKA ThermometersCasing 110x30 mm • gold-colored anodizedDIN 16181 B, B1DIN 16182 S, S1

Immersion tubes of all right-angled thermometers are manufactured with a grooved adapterpiece on top, which is installed in the casing and kept in its place by a set screw.Advantage: Immersion tube can be installed independently of thermometer casing. No turning ofthermometer casing is necessary on installation.

1) Bdr: Special execution of angle-type thermometer: After installation, casing can be turned by360° in any direction. See page 9 for description and illustration.

Page 8: Industrial-Thermometer

Protecting Tubes DIN16179 BD/BE/BSfor SIKA Thermometers withImmersion Tube Type "B", to be screwed in

DimensionsThread d1

CodeNo.

d2h14

d3 d4 d5

h11d6 d7 d8 b1 h3 h4 h5 h6 i1

±0,2r1 r2 r3 t1

min.

SpanSize

M20x1,5 7 25

G1/2 2 26 27 17 30 25 11 13 16 22 12 25 39 14 1,6 2,5 8,5 20 27

G3/4 3

M27x2 932 32 22 36 26 11 13 20 26 15 29 45 16 2,5 4 8,5 24 32

See page 15 for Works Certificates.

Page 9: Industrial-Thermometer

SIKA ThermometersRevolving angle type

This original SIKA thermometer designpermits the casing including insert to beturned by 360 degrees, after installa-

tion, so it can be read from any direction.This special SIKA thermometer type willbe applied when installation conditions

do not permit using a normal angle-typethermometer which is read from the front.

Page 10: Industrial-Thermometer

SIKA Thermometerswith separate Protecting Tubes

SIKA thermometer with immersiontube type "B", threaded socket withintegral hexagonal nut, with separateprotecting tube type "Gi" made ofsolid material (1 piece), to bescrewed in.

SIKA thermometer with immersion tubetype "B", with separate protecting tubetype "BS" for high pressures, to bewelded in.

SIKA thermometer with immersion tube type"B", threaded socket with integral hexagonalnut, with separate protecting tube type "Ei",brazed for brass, or welded for steel, to bescrewed in.

Page 11: Industrial-Thermometer

SIKA ThermometersImmersion Tube Type "Da", Union nutG 1 / 2 - G 3 / 4 - M 2 0 x 1 , 5 - M 2 7 x 2Casing 200x36mm • gold-colored anodizedDIN 16189 C,C1DIN 1 6 1 9 0 C , C 1DIN 1 6 1 9 1 C , C 1

Immersion tubes of all right-angled thermometers are manufactured with a grooved adapterpiece on top, which is installed in the casing and kept in its place by a set screw.Advantage: Immersion tube can be installed independently of thermometer casing. No turning ofthermometer casing is necessary on installation.

1)Immersion tube lengths match protecting tubes acc. to DIN 16179; see page 12 for this.

Page 12: Industrial-Thermometer

Protecting Tubes DIN16179CD/CE/CSfor SIKA Thermometers withImmersion Tube Type "Da"(connection by union nut)

DimensionsThread d1 Code

No.

d2h14

d4 d7 d8 d9h11

h2 h5 h6 i1±0,2

r1 r3 SpanSize

M20x1,5 7 25

G 1/2 2 2617 11 13 24 12 25 39 14 1,6 8,5 27

G3/4 3

M27x2 932 22 11 13 30 14 29 45 16 2,5 8,5 32

See page 15 for Works Certificates.1) Hex. nut 2.0401 - CuZn39Pb3 or 2.0402 - CuZn40Pb2 tube SoMs76 or Ms 63 brazed.

Page 13: Industrial-Thermometer

SIKA ThermometersImmersion Tube Type "Dc", Union nut M 24x1, 5Casing 200x36 mm • gold-colored anodizedDIN 1 6 1 8 9 F

On principle, thermometers of type "Dc" are supplied with a steel tube of dia. 6. 5mm for the lower part of the capillary, and which fits into protecting tubes with 7 mmbore, in order to protect the capillary and to prevent glass particles to penetrate intothe bore of the protecting tube if glass breakage occurs.

Immersion tubes of all right-angled thermometers are manufactured with a groovedadapter piece on top, which is installed in the casing and kept in its place by a setscrew. Advantage: Immersion tube can be installed independently of thermometercasing. No turning of thermometer casing is necessary on installation.

Page 14: Industrial-Thermometer

Protecting Tubes (Weld-in Type)DIN 43763 Form Dfor SIKA Thermometerswith Immersion Tube Types "Do"

Form Prot.tube

length |3 l4Free*imm.

length l1

d1

h7d2 d3 n

D1 40 50 65 24 12, 5 7 3, 5

D2 200 50 125 24 12, 5 7 3, 5D4 200 110 65 24 12, 5 7 3, 5D5 260 1 10 125 24 12. 5 7 3. 5

Design:

Fig. 1: with screw plug M 18x1. 5, brass, Code No. 000061

Fig. 2: with extension tube 165 mm, made of steel,Type "HD" Code No. 165020V

Fig. 3: with double thread nipple, made of steel Type"HDo" Code No. 00076V1) Sealing ring C 18x22 will be supplied

See page 13 for SIKA thermometers "Dc".suitable for these protecting tubes.

Attention! New!The protecting tubes D 1 - D 4 are supplied upon request with abore d3 = 3, 5 mm, d1 = 18 mm h7, d2 = 9 mm and female threadM14x1, 5.

The immersion lengths (I3) of the thermometers are as follows:

Form with extensiontube

with double threadednipple

D 1 D2/4

D5

295 mm355 mm415 mm

155 mm215mm275 mm

See page 15 for Works Certificates.

Page 15: Industrial-Thermometer

Table of Materials

The manufacture of SIKA protecting tubes is regularly controlled by theTÜV Hessen" (technical inspection service) and meets the requirementsof AD/HP O.Please inquire if you need protecting tubes made of other materials, with flange connection or PTFEcoating. Upon request, each protecting tube can be put to a pressure test or test for surface cracks,at extra charge; a Certificate DIN 50049-3.1.B/EN 10204 will be supplied.

1) Only with Works Certificate DIN 50049/2.1 or 2.2 is possible. 2) Hexagon Ms 58/tube SoMs 76 or MS63 brazed.

Select the most suitable material for your application, Please see FNE and VDE because some materials may be precluded from certainapplication.

SIKA protecting tubes can be supplied with following Certificates, at extra charge:

DIN 50049-2.1*) DIN 50049-2.2*) DIN 50049-2.3*) DIN 50049-3.1.A*) DIN 50049-3.1.B*) DIN 50049-3.1.C*)

*) EN 10204

Page 16: Industrial-Thermometer

Installation Instructions

According to specifications of the Institute of German Engineers. Weld-in protecting tubes (DIN 43 763, DIN 16179) tobe welded so that cylindrical part does not enter into medium to be measured or into cross section of conduit.

This catalogue offers different types of protecting tubes whichprotect SIKA thermometers against hazards of mechanical,thermal or chemical nature. The protecting tubes permit removalor installation of thermometers during operation.

Special attention is drawn to the fact that all SIKAthermometers with immersions tubes “B” (threaded socketwith integral hexagonal nut” are adjusted at completeimmersion length. These immersion tubes must be totallyimmersed in the medium to be measured. Should this not bepossible, and less than full immersion depth has to used,these special conditions have to be specified to avoidinaccurate reading.

For best results, thermometers with at least 63 mmimmersion tubes are recommended. On pipe conduits ofless than 100 mm dia., the whole width of conduit should beused. On bigger sizes, reaching the center of the conduit issufficient.

Installation Examples

Type "Ga"Type "B" Type "HDo"

Explanations

Page 17: Industrial-Thermometer

SIKA ThermometersSpecial Types

Maximum Thermometer for Transformers(with resetting magnet) Order Code: 2 9 1 9 21 12 150 41

Casing Immersion Tube/Thread Capillary Range

150x36 mm withgrommet

1 5 0 x 1 0 m mbrass G 1"

white-backedmercury filling,long steel mark

+20 +120°C

Order Code: 277 0 12 11 000 00

200x36 mmwith suspensionring on top

with short, perforatedreservoir

white-backedblue liquid

0 +120°C

Order Code:Type 278 Ambient Measuring -30+ 50°c = 273 o 35 11 ooo oo

Thermometers o+100° c = 278 0 1 0 11 o o o o o

200x36 mmwith suspensionring on top

no lower part white-backedblue liquid

-30 + 50° C 0 +100°C

Special Executions of SIKA Thermometers (at extra charge)

• Thermometer with two limit indicators which can be adjusted to any interval

• Thermometer with grommet which prevents moisture from entering into the immersion tube (outdoor installation)

• SIKA industrial thermometers complete stainless steel

Grommet

Type291 BM

Tank ScoopingThermometersType 277

• Blue shining mercury filling. Can onlybe supplied for temperatures upto+400° C

• Immersion tubes brass or steel nickelplated

• Casing silver-coloured

• Thermometer without any parts ofbrass, bronze or similar materials

Thermometerwith Limit Indicators

Page 18: Industrial-Thermometer

Thermometer Inserts(Replacement inserts)

Page 19: Industrial-Thermometer

Spare Parts

Thermometer Casings