This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
INDUSTRIAL CONTROLLERS
For Industrial IOT Applications
NORVI IIOT
Ready for the futureNORVI IIOT
24+
POWER
GND COM I.0 I.1 I.2 I.3 I.4 I.5 I.6 I.7
COM Q.0 Q0.1 Q.2 Q.3 Q.4 Q.5 T+ T- P.0 P.1
PWR
RUN
I.0 I.1 I.2 I.3 I.4 I.5 I.6 I.7
Q.0 Q.1 Q.2 Q.3 Q.4 Q.5 P.0 P1
ICONIC
Arduino Micro
0.96 OLED Display8 - 24v Digital Inputs6 - Relay outputs
NORVI
24+
POWER
GND COM I.0 I.1 I.2 I.3 I.4 I.5 I.6 I.7
COM Q.0 Q0.1 Q.2 Q.3 Q.4 Q.5 T+ T- P.0 P.1
PWR
RUN
I.0 I.1 I.2 I.3 I.4 I.5 I.6 I.7
Q.0 Q.1 Q.2 Q.3 Q.4 Q.5 P.0 P1
inside
IIOTn
EN 61131-2:2007EN 61010-1:2010+A1:2019EN IEC 61010-2-201:2018
EN 61131-2:2007EN 61010-1:2010+A1:2019EN IEC 61010-2-201:2018
2014/30/EU- Electromagnetic Compatibility (EMC)Annex III, Part B, Module C
Product line....
8 Digital Inputs
6 Relay outputs
2 Transistor outputs
0.96 OLED Display
8 Digital Inputs
6 analog inputs 0 to 10V
0.96 OLED Display
NORVI-IIOT-AE01-R
NORVI-IIOT-AE02-V
RS 485 Communica�on
RS 485 Communica�on
8 Digital Inputs
NORVI-IIOT-AE03
8 Digital Inputs
8 Transistor outputs
0.96 OLED Display
RS 485 Communica�on
8 Digital Inputs
6 analog inputs 4 - 20mA
0.96 OLED Display
NORVI-IIOT-AE02-I
RS 485 Communica�on
Expansions supported
LoRa communications REYAX RYLR896
NB-IOTBC95 module
TemperatureMAX31856
Analog4-20mA / 0 - 10V
Load cellHX-711
NORVI-IIOT-AE01-R
6 Digital Inputs
6 analog inputs 0 to 10V
0.96 OLED Display
NORVI-IIOT-AE04-V
RS 485 Communica�on
6 Digital Inputs
6 analog inputs 4 - 20mA
0.96 OLED Display
NORVI-IIOT-AE04-I
RS 485 Communica�on
microSD card support microSD card support
DS3231 RTC DS3231 RTC
1 analog inputs 0 to 10V (12 bit)
FeaturesSOC
Power supply characteristics12 ~ 24V DC
Connection of the embedded IOConnection is performed through xed screw terminal blocks (at intervals of5.08 mm/0.200 in.)
Digital Inputs24V DC Sink Source congurable by changing the common line
Head office183, Maharagama RoadBoralasgamuwa, Sri Lanka
The information provided in this documentation contains general descriptions and/or technicalcharacteristics of the performance of the products contained herein. This documentation is notintended as a substitute for and is not to be used for determining suitability or reliability of theseproducts for specific user applications. It is the duty of any such user or integrator to perform theappropriate and complete risk analysis, evaluation and testing of the products with respect to therelevant specific application or use thereof. Neither Schneider Electric nor any of its affiliates orsubsidiaries shall be responsible or liable for misuse of the information contained herein.