207842 © di-soric | Subject to modifications | 12/12/14 | Page 1 (1) DCCR 80 K 50 PSOL-KL Inductive Proximity Switch di-soric GmbH & Co. KG Steinbeisstraße 6 DE-73660 Urbach Fon + 49 (0) 71 81 / 98 79 - 0 Fax + 49 (0) 71 81 / 98 79 - 179 [email protected] www.di-soric.com TECHNICAL INFORMATION (typ.) +20°C, 24V DC Operating principle Inductive Evaluation digital Size 80 x 80 x 40 mm (Dimensions) Design cuboid design Mounting non-flush Operating distance 50 mm Standardized measuring plate 150 x 150 x 1 mm Service voltage 10 ... 30 V DC Internal power consumption < 10 mA Switching output pnp, 200 mA, NO/NC, exclusive OR Switching hysteresis < 15 % LED indicator yes Voltage drop < 2,4 V Operating frequency 100 Hz Ambient temperature -25 … +70 °C Insulation voltage endurance 500 V Protection class IP 67 Casing material plastics (polycarbonate - PC) Connection Connection compartment for 4 x 1,5 mm² 80 80 65 65 5 PG 13,5 11 BN = brown BK = black WH = white BU = blue BN BK BU 1 4 3 pnp WH 2 S S pnp Safety instructions The Instruments are not to be used for safety applications, in particular applications in which safety of persons depends on proper operation of the instruments. These instruments shall exclusively be used by qualified personnel. Connection clamps Protection against short-circuit and reverse polarity LED indicatior for output state High protection class IP 67