Phone: +44 (0)1553 810778 Email: [email protected]web: www.carteraccommodation.com Carter Cabin Hire Ltd | Garage Lane Industrial Estate | Setchey | Kings Lynn | Norfolk | PE33 0BE VAT no. 750 7231 49 | Registered in England & Wales no. 2479578 INDIVIDUAL ECO AND ANTI VANDAL CABINS All rates listed are for weekly hire. 32’ 24’ 21’ 20’ 16’ 12’/10’ OFFICE E/U 1 Anti Vandal Eco Rated SPLIT OFFICE E/U 2 Anti Vandal Eco Rated CANTEEN / TOILET E/U 3 Anti Vandal Eco Rated DRYING ROOM / TOILET E/U 4 Anti Vandal Eco Rated CANTEEN E/U 5 Anti Vandal Eco Rated CANTEEN / DRYING E/U 6 Anti Vandal Eco Rated DRYING ROOM E/U 7 Anti Vandal Eco Rated TOILET / SHOWER E/U 8 Anti Vandal Eco Rated STORE Anti Vandal
18
Embed
INDIVIDUAL ECO AND ANTI VANDAL CABINS€¦ · INDIVIDUAL ECO AND ANTI VANDAL CABINS All rates listed are for weekly hire. ... PROPOSED 16' x 9' DOUBLE STACKED SECURE STEEL ECO UNIT
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
16'x9' SECURE STEEL JACKLEG ECO UNITS, LINKWAYSAND STAIRCASES - PLAN LAYOUT PRODUCT RANGE
TB
NPTS
05 / 12 / 14
16' E/Us
ECO PRODUCT RANGE PRODUCT SELECTOR
QUANT
16'x9' CANTEEN UNIT
16'x9' 3+1 TOILET UNIT
16'x9' DRYING UNIT
16'x10' TOILET/DDA/SHOWER
16'x9' SINGLE OFFICE UNIT
DESCRIPTION
E/U 2
E/U 3
E/U 4
E/U 1
UNIT
DEFG
CB 45A
76-100
101-125
126-150
Over 150
51-75
26-50
0-25
DEFG
CB 45A
76-100
101-125
126-150
Over 150
51-75
26-50
0-25
This is how energy efficientthe building is.
ECO
E/U 5
CarterAccommodation
E/U 1 /16END ELEVATION
E/U 1 /16FRONT ELEVATION
E/U 2 /16END ELEVATION
E/U 2 /16FRONT ELEVATION
E/U 3 /16END ELEVATION
E/U 3 /16FRONT ELEVATION
E/U 4 /16END ELEVATION
E/U 4 /16FRONT ELEVATION
E/U 5 /16END ELEVATION
E/U 5 /16FRONT ELEVATION
TB
1:75
Revisions Drawn
Scale
Date
Drg No
Client
Title 29 / 06 / 15
16x9 E/U E
PROPOSED STANDARD SPECIFICATION 16'x9'JACKLEG ECO UNITS - ELEVATIONS
CarterAccommodation
27
67
J/le
gct
s
PROPOSED 16' x 9' DOUBLE STACKEDSECURE STEEL ECO UNIT - FOUNDATIONS
BJGH
1 : 50
05 / 04 / 11
Revisions Drawn
Scale
Date
Drg No 16'x9' DS-founds
Client
Title
ALL SUBJECT TO LOCAL AUTHORITY BUILDING CONTROL APPROVAL
FOUNDATION PADS OF 600 x 600mm MASSCONCRETE BASE (C20P MIX) FOUNDED ONSUITABLE SUBSTRATE DEPTH/HEIGHT OFFOUNDATIONS SUBJECT TO GROUND CONDITIONS& GROUND BEARING PRESSURES.PRESCRIBED MIX FOR BASE ONLY APPLIES TONON AGGRESSIVE SOIL CONDITIONS.
500 500 3500
C INE OF DOOR & LANDING
11
00
60
03
50
STAIRCASE
26
40
2438 J/leg cts
4880
FOUNDATION PLANBASED UPON MINIMUM GROUND BEARINGPRESSURE OF 107kN/m²
Point Load35.31kN
Point Load35.31kN
Point Load35.31kN
Point Load35.31kN
50mm
min. 450mm
GL
Expandableholdingdown bolts
CarterAccommodation
2438 J/leg cts
4880
30
82
J/le
gct
s
PROPOSED 16' x 10' 2+DISABLED+SHOWERSECURE STEEL ECO UNIT - FOUNDATIONS
BJGH
1 : 50
13 / 12 / 10
A: POINT LOADINGS ADDED. 03/06/13 BJGHRevisions Drawn
Scale
Date
Drg No 16'x10' founds
Client
Title
ALL SUBJECT TO LOCAL AUTHORITY BUILDING CONTROL APPROVAL
FOUNDATION PADS OF 600 x 600mm PRECASTCONCRETE PAVING SLABS BEDDED & LEVELLEDWITH SAND CEMENT MORTAR (1:3) ONTO MASSCONCRETE BASE (C20P MIX) FOUNDED ONSUITABLE SUBSTRATE DEPTH/HEIGHT OFFOUNDATIONS SUBJECT TO GROUND CONDITIONS& GROUND BEARING PRESSURES.PRESCRIBED MIX FOR BASE ONLY APPLIES TONON AGGRESSIVE SOIL CONDITIONS.
min. 50mm
min. 300mm
GL
Point Load35.31kN
Point Load35.31kN
Point Load35.31kN
Point Load35.31kN
500 500 3500
11
00
60
03
50
CarterAccommodation
E/U 4 /20
SC 3SC 2SC 1
E/U 6 /20
E/U 1 /20
E/U 2 /20 E/U 5 /20
Client
Title
DRAWN
SCALE
DATE
DRG No.
Revisions
20'x9' SECURE STEEL JACKLEG ECO UNITS, LINKWAYSAND STAIRCASES - PLAN LAYOUT PRODUCT RANGE
TB
NPTS
05 / 12 / 14
20' E/Us
ECO PRODUCT RANGE PRODUCT SELECTOR
QUANT
24'x9' 4+1 TOILET UNIT
LONG LANDING STAIRCASE
20'x9' 60/40 OFFICE UNIT
20'x9' CANTEEN/DRY UNIT
DOUBLE LANDING STAIRCASE
20'x9' CANTEEN UNIT
20'x9' DRYING UNIT
STANDARD STEEL STAIRCASE
20'x9' SINGLE OFFICE UNIT
DESCRIPTION
SC 2
E/U 2
SC 3
E/U 3
E/U 4
SC 1
E/U 1
UNIT
DEFG
CB 45A
76-100
101-125
126-150
Over 150
51-75
26-50
0-25
DEFG
CB 45A
76-100
101-125
126-150
Over 150
51-75
26-50
0-25
This is how energy efficientthe building is.
ECO
E/U 3 /20
E/U 5
E/U 6
3658 J/Leg Cts.
27
67
J/L
eg
Cts
.
2640
6100
isolator
1.5kW OFR c/w timer.
RCD
810CylinderDC
500
T/TT/T
4No. h&c hooks@1800mm ab. ffl.
4
Hig
hF
req
uen
cyC
at2
4
Hig
hF
req
uen
cyC
at2
4
Hig
hF
req
uen
cyC
at2
Fused spur. for w/heater at1700mm ab. ffl. with box & blankplate @400mm ab.ffl. c/w earth.
400
Fused spur. for w/heater at1700mm ab. ffl. with box & blankplate @400mm ab.ffl. c/w earth.
400400
3658 J/Leg Cts.
27
67
J/L
eg
Cts
.
2640
6100
isolator
1.5kW OFR c/w timer.
RCD
810CylinderDC
500
T/TT/T
4No. h&c hooks@1800mm ab. ffl.
4
Hig
hF
req
uen
cyC
at2
4
Hig
hF
req
uen
cyC
at2
4
Hig
hF
req
uen
cyC
at2
Fused spur. for w/heater at1700mm ab. ffl. with box & blankplate @400mm ab.ffl. c/w earth.
400
Fused spur. for w/heater at1700mm ab. ffl. with box & blankplate @400mm ab.ffl. c/w earth.
400400
tea
bo
iler
3658 J/Leg Cts.
27
67
J/L
eg
Cts
.
2640
6100
isolator
1.5kW OFR c/w timer.
RCD
810CylinderDC
500
4
Hig
hF
req
uen
cy
4
Hig
hF
req
uen
cy
4
Hig
hF
req
uen
cy
T/TT/T
4No. h&c hooks@1800mm ab. ffl.
600
x100
0mm
s.s.
sin
kun
it
Fused spur. for w/heater at1700mm ab. ffl. with box & blankplate @400mm ab.ffl. c/w earth.
400400
teabo
iler
3658 J/Leg Cts.
27
67
J/L
eg
Cts
.
2640
6100
isolator
1.5kW OFR c/w timer.
RCD
810CylinderDC
4
Hig
hF
req
uen
cy
4
Hig
hF
req
uen
cy
4
Hig
hF
req
uen
cy
T/TT/T
600
x100
0m
ms.s.sin
ku
nit
SL
3kW high levelfan heater
Fused spur. for w/heater at1700mm ab. ffl. with box & blankplate @400mm ab.ffl. c/w earth.
400
8262L
15No. hat & coathooks mounted on
softwood pinrail@1800mm ab.ffl.
3658 J/Leg Cts.
27
67
J/L
eg
Cts
.
2640
6100
isolator
RCD
810CylinderDC
500
4
Hig
hF
req
uen
cy
4
Hig
hF
req
uen
cy
4
Hig
hF
req
uen
cy
T/TT/T
Fused spur. for w/heater at1700mm ab. ffl. with box & blankplate @400mm ab.ffl. c/w earth.
400400
3kW high levelfan heater c/wdisabled stat.
Fused spur. for w/heater at1700mm ab. ffl. with box & blankplate @400mm ab.ffl. c/w earth.
400HR100WH Heatexchange extractwith humidity stat
@ 2000mm affl.34No. hat & coat
hooks mounted onsoftwood pinrail
@1800mm ab. ffl.
810CylinderDC
810cylinderDC
PIR WaterHeater
df df df dfdf
wdp
M
Concealedstat.
Concealedstat.
wdpwdp
H/L
H/L
M
M
Concealed stat.uswh
RCD
H/L
4
Hig
hF
req
uen
cy
4
Hig
hF
req
uen
cy
4
Hig
hF
req
uen
cy
Waterless Urinals
isolator
100mmwastethro' wall
15mmwaterthro' wall
3658 J/Leg Cts.
27
67
J/L
eg
Cts
.
2640
6100
CarterAccommodation
E/U 1 /20END ELEVATION
E/U 1 /20FRONT ELEVATION
E/U 2 /20END ELEVATION
E/U 2 /20FRONT ELEVATION
E/U 3 /20END ELEVATION
E/U 3 /20FRONT ELEVATION
E/U 4 /20END ELEVATION
E/U 4 /20FRONT ELEVATION
E/U 5 /20END ELEVATION
E/U 5 /20FRONT ELEVATION
E/U 6 /20END ELEVATION
E/U 6 /20FRONT ELEVATION
TB
NTS
Revisions Drawn
Scale
Date
Drg No
Client
Title 29 / 06 / 15
20x9 E/U E
PROPOSED STANDARD SPECIFICATION 20'x9'JACKLEG ECO UNITS - ELEVATIONS
CarterAccommodation
MAH
1:50
16 / 02 / 11
Revisions Drawn
Scale
Date
Drg No
Client
Title
20' x 9' fndsDS
ALL SUBJECT TO LOCAL AUTHORITY BUILDING CONTROL APPROVAL
FOUNDATION PADS OF 600 x 900mm PRECASTCONCRETE PAVING SLABS BEDDED & LEVELLEDWITH SAND CEMENT MORTAR (1:3) ONTO MASSCONCRETE BASE (C20P MIX) FOUNDED ONSUITABLE SUBSTRATE DEPTH/HEIGHT OFFOUNDATIONS SUBJECT TO GROUND CONDITIONS& GROUND BEARING PRESSURES.PRESCRIBED MIX FOR BASE ONLY APPLIES TONON AGGRESSIVE SOIL CONDITIONS.
27
67
J/le
gct
s
3658 J/leg cts
6100
26
40
FOUNDATION PLANBASED UPON MINIMUM GROUNDBEARING PRESSURE OF 105kN/m²
50mm
min. 450mm
GL
Expandableholdingdown bolts
60
02
88
93
8
14298001429
PROPOSED DOUBLE STACKED 20'x9' SECURESTEEL JACKLEG UNITS - FOUNDATION LAYOUT
2269UnfactoredPoint Load39.93kN
UnfactoredPoint Load39.93kN
UnfactoredPoint Load39.93kN
UnfactoredPoint Load39.93kN
CarterAccommodation
E/U 5 /24
L 4SC 3SC 2
SC 1L 6L 5L 3L 2L 1
E/U 7 /24
E/U 8 /24
E/U 1 /24
E/U 2 /24 E/U 6 /24
Client
Title
DRAWN
SCALE
DATE
DRG No.
Revisions
24'x9' SECURE STEEL JACKLEG ECO UNITS, LINKWAYSAND STAIRCASES - PLAN LAYOUT PRODUCT RANGE
TB
NPTS
05 / 12 / 14
24' E/Us
910CylinderDC
910CylinderDC
ECO PRODUCT RANGE PRODUCT SELECTOR
QUANT
24'x9' DRYING UNIT
600mm LINKWAY
LONG LANDING STAIRCASE
24'x9' 60/40 OFFICE UNIT
24'x9' CANTEEN UNIT
2100mm LINKWAY
1200mm LINKWAY
DOUBLE LANDING STAIRCASE
24'x9' 50/50 OFFICE UNIT
24'x9' CANTEEN/DRY UNIT
300mm 'BUTT' LINKWAY
2100mm LINK c/w DOOR
1200mm LINK c/w DOOR
STANDARD STEEL STAIRCASE
24'x9' SINGLE OFFICE UNIT
DESCRIPTION
E/U 7
L 2
L 5
SC 2
E/U 2
E/U 8
L 3
L 6
SC 3
E/U 3
E/U 4
L 1
L 4
SC 1
E/U 1
UNIT
DEFG
CB 45A
76-100
101-125
126-150
Over 150
51-75
26-50
0-25
DEFG
CB 45A
76-100
101-125
126-150
Over 150
51-75
26-50
0-25
This is how energy efficientthe building is.
ECO
E/U 3 /24
E/U 4 /24
E/U 5
E/U 6
4268 J/Leg Cts.
2767
J/Le
gC
ts.
2640
7316
810CylinderDC
T/T
isolator
RCD
4No h&c hooks@1800mm ab. ffl.
T/T
1.5kW OFR c/w timer.
Fused spur. for w/heater at1700mm ab. ffl. with box & blankplate @300mm ab.ffl. c/w earth.
400
1.5kW OFR c/w timer.
Fused spur. for w/heater at1700mm ab. ffl. with box & blankplate @300mm ab.ffl. c/w earth.
400
4
Hig
hFr
eque
ncy
Cat
2
4
Hig
hFr
eque
ncy
Cat
2
4
Hig
hFr
eque
ncy
Cat
2
4268 J/Leg Cts.
2767
J/Le
gC
ts.
2640
7316
810CylinderDC
T/T
isolator
RCD
4No h&c hooks@1800mm ab. ffl.
T/T
1.5kW OFR c/w timer.
Fused spur. for w/heater at1700mm ab. ffl. with box & blankplate @300mm ab.ffl. c/w earth.
400
1.5kW OFR c/w timer.
Fused spur. for w/heater at1700mm ab. ffl. with box & blankplate @300mm ab.ffl. c/w earth.
400
4
Hig
hFr
eque
ncy
Cat
2
4
Hig
hFr
eque
ncy
Cat
2
4
Hig
hFr
eque
ncy
Cat
2
8382L
4268 J/Leg Cts.
2767
J/Le
gC
ts.
2640
7316
810CylinderDC
T/T
isolator
RCD
4No h&c hooks@1800mm ab. ffl.
T/T
1.5kW OFR c/w timer.
Fused spur. for w/heater at1700mm ab. ffl. with box & blankplate @300mm ab.ffl. c/w earth.
400
1.5kW OFR c/w timer.
Fused spur. for w/heater at1700mm ab. ffl. with box & blankplate @300mm ab.ffl. c/w earth.
400
4
Hig
hFr
eque
ncy
Cat
2
4
Hig
hFr
eque
ncy
Cat
2
4
Hig
hFr
eque
ncy
Cat
2
8382L
8382L
4268 J/Leg Cts.
2767
J/Le
gC
ts.
2640
7316
810CylinderDC
4
Hig
hFr
eque
ncy
4
Hig
hFr
eque
ncy
4
Hig
hFr
eque
ncy
T/T
T/T
isolator
RCD
4No h&c hooks@1800mm ab. ffl.
T/T
600x
1000
mm
s.s.
sink
unit
tea
boile
r
1.5kW OFR c/w timer.
Fused spur. for w/heater at1700mm ab. ffl. with box & blankplate @300mm ab.ffl. c/w earth.
400
1.5kW OFR c/w timer.
4268 J/Leg Cts.
2767
J/Le
gC
ts.
2640
7316
810CylinderDC
T/T
isolator
RCD
T/T
Fused spur. for w/heater at1700mm ab. ffl. with box & blankplate @300mm ab.ffl. c/w earth.
400
Fused spur. for w/heater at1700mm ab. ffl. with box & blankplate @300mm ab.ffl. c/w earth.
400
4
Hig
hFr
eque
ncy
4
Hig
hFr
eque
ncy
4
Hig
hFr
eque
ncy
40No. hat & coathooks mounted on
softwood pinrail@1800mm ab. ffl.
3kW high levelfan heater c/wdisabled stat.
3kW high levelfan heater c/wdisabled stat.
HR100WH Heatexchange extractwith humidity stat
@ 2000mm affl.
4268 J/Leg Cts.
2767
J/Le
gC
ts.
2640
7316
810CylinderDC
4
Hig
hFr
eque
ncy
4
Hig
hFr
eque
ncy
4
Hig
hFr
eque
ncy
T/T
isolator
RCD
4No h&c hooks@1800mm ab. ffl.
T/T
600x
1000
mm
s.s.
sink
unit
tea
boile
r
Fused spur. for w/heater at1700mm ab. ffl. with box & blankplate @300mm ab.ffl. c/w earth.
1.5kW OFR c/w timer.
400
8382L
20No. Hat & coathooks mounted on
softwood pinrail@1800mm ab. ffl.
3kW high levelfan heater c/wdisabled stat.
df dfdf df dfdf
Concealedstat.
Concealedstat.
H/L
H/L
M
M
Concealed stat.
H/L
4
Hig
hFr
eque
ncy
4
Hig
hFr
eque
ncy
4
Hig
hFr
eque
ncy
Waterless Urinals
810CylinderDC
810cylinder
DC
wdp
wdp
RCDM
1050
uswh
uswh
isolator
100mmwastethro' wall
15mmwaterthro' wall
810CylinderDC
810CylinderDC
df df df df dfdf
wdp
M
Concealedstat.
Concealedstat.
wdpwdp
H/L
H/L
M
M
Concealed stat.
uswh
uswh
RCD
H/L
4
Hig
hFr
eque
ncy
4
Hig
hFr
eque
ncy
4
Hig
hFr
eque
ncy
4
Hig
hFr
eque
ncy
Waterless Urinals
M
100mmwastethro' wall
15mmwaterthro' wall
4268 J/Leg Cts.
2767
J/Le
gC
ts.
2640
7316
4268 J/Leg Cts.
2767
J/Le
gC
ts.
2640
7316
24'x9' 4+2 TOILET UNIT
24'x9' 5+1 TOILET UNIT
CarterAccommodation
E/U 1 /24END ELEVATION
E/U 1 /24FRONT ELEVATION
E/U 2 /24END ELEVATION
E/U 2 /24FRONT ELEVATION
E/U 3 /24END ELEVATION
E/U 3 /24FRONT ELEVATION
E/U 4 /24END ELEVATION
E/U 4 /24FRONT ELEVATION
E/U 5 /24END ELEVATION
E/U 5 /24FRONT ELEVATION
E/U 6 /24END ELEVATION
E/U 6 /24FRONT ELEVATION
E/U 7 /24END ELEVATION
E/U 7 /24FRONT ELEVATION
E/U 8 /24END ELEVATION
E/U 8 /24FRONT ELEVATION
Client
Title
DRAWN
SCALE
DATE
DRG No.
Revisions
PROPOSED STANDARD SPECIFICATION 24'x9'JACKLEG ECO UNITS - ELEVATIONS
TB
NTS
29 / 06 / 15
24x9 E-U E
CarterAccommodation
27
67
J/le
gct
s
PROPOSED 24' x 9' DOUBLE STACKEDSECURE STEEL ECO UNIT - FOUNDATIONS
BJGH
1 : 50
16 / 06 / 11
Revisions Drawn
Scale
Date
Drg No 24'x9' DS-founds
Client
Title
ALL SUBJECT TO LOCAL AUTHORITY BUILDING CONTROL APPROVAL
FOUNDATION PADS OF 900 x 600mm MASSCONCRETE BASE (C20P MIX) FOUNDED ONSUITABLE SUBSTRATE DEPTH/HEIGHT OFFOUNDATIONS SUBJECT TO GROUND CONDITIONS& GROUND BEARING PRESSURES.PRESCRIBED MIX FOR BASE ONLY APPLIES TONON AGGRESSIVE SOIL CONDITIONS.
500 500 3500
110
0
600
350
STAIRCASE
26
40
4270 J/leg cts
7315
FOUNDATION PLANBASED UPON MINIMUM GROUND BEARING
PRESSURE OF 107kN/m²
Point Load49.96kN
Point Load49.96kN
Point Load49.96kN
Point Load49.96kN
50mm
min. 450mm
GL
Expandableholdingdown bolts
CarterAccommodation
E/U 5 /32
L 4SC 3SC 2
SC 1L 6L 5L 3L 2L 1
E/U 7 /32
E/U 8 /32
E/U 1 /32
E/U 2 /32 E/U 6 /32
Client
Title
DRAWN
SCALE
DATE
DRG No.
Revisions
32'x10' SECURE STEEL JACKLEG ECO UNITS, LINKWAYSAND STAIRCASES - PLAN LAYOUT PRODUCT RANGE
TB
NPTS
05 / 12 / 14
32' E/Us
910CylinderDC
910CylinderDC
ECO PRODUCT RANGE PRODUCT SELECTOR
QUANT
32'x10' DRYING ROOM UNIT
600mm LINKWAY
LONG LANDING STAIRCASE
32'x10' 50/50 OFFICE UNIT
32'x10' 5+1+Sh TOILET UNIT
2100mm LINKWAY
1200mm LINKWAY
DOUBLE LANDING STAIRCASE
32'x10' CANTEEN/WC UNIT
32'x10' CANTEEN/DRY UNIT
300mm 'BUTT' LINKWAY
2100mm LINK c/w DOOR
1200mm LINK c/w DOOR
STANDARD STEEL STAIRCASE
32'x10' SINGLE OFFICE UNIT
DESCRIPTION
E/U 7
L 2
L 5
SC 2
E/U 2
E/U 8
L 3
L 6
SC 3
E/U 3
E/U 4
L 1
L 4
SC 1
E/U 1
UNIT
DEFG
CB 45A
76-100
101-125
126-150
Over 150
51-75
26-50
0-25
DEFG
CB 45A
76-100
101-125
126-150
Over 150
51-75
26-50
0-25
This is how energy efficientthe building is.
ECO
E/U 3 /32
E/U 4 /32
E/U 5
E/U 6
32'x10' CANTEEN UNIT
32'x10' HEART UNIT
810CylinderDC
T/T
T/T
T/T T/T
isolator
RC
D
2g
1.5kW OFR c/w timer.
1.5kW OFR c/w timer.
5487 J/Leg Cts.
9752
3082
J/Le
gC
ts.
4No. h&c hooks@1800mm ab. ffl.
Fused spur. for w/heater at1700mm ab. ffl. with box & blankplate @300mm ab.ffl. c/w earth.
400
Fused spur. for w/heater at1700mm ab. ffl. with box & blankplate @300mm ab.ffl. c/w earth.
400
4
Hig
hFr
eque
ncy
Cat
2
4
Hig
hFr
eque
ncy
Cat
2
4
Hig
hFr
eque
ncy
Cat
2
4
Hig
hFr
eque
ncy
Cat
2
4
Hig
hFr
eque
ncy
Cat
2
2960
810CylinderDC
T/T
T/T
T/T T/T
isolator
RC
D
2g
1.5kW OFR c/w timer.
1.5kW OFR c/w timer.
5487 J/Leg Cts.
2960
9752
3082
J/Le
gC
ts.
4No. h&c hooks@1800mm ab. ffl.
Fused spur. for w/heater at1700mm ab. ffl. with box & blankplate @300mm ab.ffl. c/w earth.
400
Fused spur. for w/heater at1700mm ab. ffl. with box & blankplate @300mm ab.ffl. c/w earth.
400
4
Hig
hFr
eque
ncy
Cat
2
4
Hig
hFr
eque
ncy
Cat
2
4
Hig
hFr
eque
ncy
Cat
2
4
Hig
hFr
eque
ncy
Cat
2
4
Hig
hFr
eque
ncy
Cat
2
8382L
8382L
810CylinderDC
4
Hig
hFr
eque
ncy
4
Hig
hFr
eque
ncy
4
Hig
hFr
eque
ncy
4
Hig
hFr
eque
ncy
4
Hig
hFr
eque
ncy
T/T
T/T
T/T T/T
isolator
RC
D
2g
1.5kW OFR c/w timer.
1.5kW OFR c/w timer.
5487 J/Leg Cts.
2960
9752
3082
J/Le
gC
ts.
4No. h&c hooks@1800mm ab. ffl.
Fused spur. for w/heater at1700mm ab. ffl. with box & blankplate @300mm ab.ffl. c/w earth.
400
600x
1000
mm
s.s.
sink
unit
42mmwaste
thro' wall
15mmwater
thro' wall
tea
boile
r
810CylinderDC
4
Hig
hFr
eque
ncy
4
Hig
hFr
eque
ncy
4
Hig
hFr
eque
ncy
4
Hig
hFr
eque
ncy
4
Hig
hFr
eque
ncy
T/T
T/T
T/T T/T
isolator
RC
D
2g1.5kW OFR c/w timer.
5487 J/Leg Cts.
2960
9752
3082
J/Le
gC
ts.
4No. h&c hooks@1800mm ab. ffl.
Fused spur. for w/heater at1700mm ab. ffl. with box & blankplate @300mm ab.ffl. c/w earth.
400
600x
1000
mm
s.s.
sink
unit
42mmwaste
thro' wall
15mmwater
thro' wall
tea
boile
r
8382L
20No. Hat & coathooks mounted on
softwood pinrail@1800mm ab. ffl.
3kW high levelfan heater c/wdisabled stat.
5487 J/Leg Cts.
2960
9752
T/TRCD
1000CylinderVPDC
4
Hig
hFr
eque
ncy
100mmwasteoutlet
15mmwaterinlet
H/L
H/L
H/L
8263LDC
8263LDC
M
4
High Frequency
4
High Frequency
4
Hig
hFr
eque
ncy
Waterless Urinals
M
T
926S/core
IB2L 15
00in
t.
2200 int.
Mus
wh
wdp
Con
ceal
edS
tat.
PIR WaterHeater
df
df df
wdp
Concealed Stat.
Concealed Stat.
HD
HD
4" extractc/w run
on timer
isolator
3082
J/Le
gC
ts.
4
Hig
hFr
eque
ncy
4
Hig
hFr
eque
ncy
T/T
1.5kW OFR c/w timer.
600x
1000
mm
s.s.
sink
unit
42mmwaste
thro' wall
15mmwater
thro' wall
tea
boile
r
810CylinderDC
4
Hig
hFr
eque
ncy
4
Hig
hFr
eque
ncy
4
Hig
hFr
eque
ncy
4
Hig
hFr
eque
ncy
4
Hig
hFr
eque
ncy
T/T
T/T
T/T T/T
RC
D
2g
5487 J/Leg Cts.
2960
9752
3082
J/Le
gC
ts.
Fused spur. for w/heater at1700mm ab. ffl. with box & blankplate @300mm ab.ffl. c/w earth.
400
400
3kW high levelfan heater c/wdisabled stat.
3kW high levelfan heater c/wdisabled stat.
60No. hat & coathooks mounted on
softwood pinrail@1800mm ab. ffl.
concealedroom stat.
Fused spur. for w/heater at1700mm ab. ffl. with box & blankplate @300mm ab.ffl. c/w earth.
CEILING HEIGHT - 2235mmEXTERNAL - 1.6mm 2 CORRY STEEL, WITH
PAINT FINISH.INTERNAL - VINYL FACED PLASTERBOARD, WHITE
DOLOMITE TO WALLS, WHITE DOLOMITE TO CEILINGS.WINDOWS - WHITE uPVC FRAMED DOUBLE GLAZEDT/T - 914 x 914mm TILT & TURN WITH LOW E GLASS,
FITTED WITH SIDE HUNG STEEL SHUTTERS INSULATED& LOCKABLE FROM INSIDE FITTED WITH HOLD OPEN CATCHES.
DOOR - COMPOSITE STEEL DOOR WITH MULTIPOINT LOCK.INSULATION - 100mm NON-ITCH LOW ENVIRONMENTAL IMPACT TO
FLOORS, WALLS & ROOF.
LIGHTING - CENTRAL LIGHT CONTROLLEDBY LIGHT SWITCH, ALL OTHERSCONTROLLED BY PIR SENSORS.TIMERS TO HEATERS.FULLY INSULATED ENVELOPE.D/GLAZED uPVC TILT & TURN WINDOWS.INSULATION TO SHUTTERS & DOORS.
ECO-UNIT FEATURES
CarterAccommodation
E/U 1 /32END ELEVATION
E/U 1 /32FRONT ELEVATION
E/U 2 /32END ELEVATION
E/U 2 /32FRONT ELEVATION
E/U 5 /32END ELEVATION
E/U 5 /32FRONT ELEVATION
E/U 6 /32END ELEVATION
E/U 6 / 32FRONT ELEVATION
E/U 3 /32END ELEVATION
E/U 3 /32FRONT ELEVATION
E/U 4 /32END ELEVATION
E/U 4 /32FRONT ELEVATION
E/U 7 /32END ELEVATION
E/U 7 /32FRONT ELEVATION
E/U 8 /32END ELEVATION
E/U 8 /32FRONT ELEVATION
Client
Title
DRAWN
SCALE
DATE
DRG No.
Revisions
PROPOSED STANDARD SPECIFICATION 32'x10'JACKLEG ECO UNITS - ELEVATIONS
TB
NTS
29 / 06 / 15
32'x10' E/U E
CarterAccommodation
MAH
1:50
07 / 05 / 0432' x 10' STANDARD HIRE SPECIFICATION
Revisions Drawn
Scale
Date
Drg No
Client
Title
DS 32'JACKLEG UNIT - FOUNDATION LAYOUT
rwp
rwp
5487 J/leg cts
3082
2990
J/le
gct
s
9770
FOUNDATION PLANBASED UPON MINIMUM GROUNDBEARING PRESSURE OF 78kN/m²
Point Load62.80kN/leg
Point Load62.80kN/leg
Point Load62.80kN/leg
Point Load62.80kN/leg
13962344800
60
03
05
95
5
50mm
min. 300mm
GL
anti crackreinforcementmesh
SUGGESTED REINFORCED PAD FOUNDATIONS OF900 x 900mm WIDE REINFORCED IN-SITU CASTMASS CONCRETE BASE ( C20P MIX ) FOUNDEDON SUITABLE SUBSTRATE DEPTH AND HEIGHTOF FOUNDATIONS SUBJECT TO GROUND CONDITIONSAND GROUND BEARING PRESSURES. PRISCRIBEDMIX FOR BASE ONLY APPLIES TO NON AGGRESSIVESOIL CONDITIONS.
ALL SUBJECT TO LOCAL AUTHORITYBUILDING CONTROL APPROVAL