Top Banner
PUBLIC INDIVIDUAL DEVICE ANALYSIS USING HYBRID TEM-SCALPEL SSRM METROLOGY UMBERTO CELANO Senior Researcher Materials & Components Analysis [email protected]
30

INDIVIDUAL DEVICE ANALYSIS USING HYBRIDTEM-SCALPEL …

Mar 12, 2022

Download

Documents

dariahiddleston
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: INDIVIDUAL DEVICE ANALYSIS USING HYBRIDTEM-SCALPEL …

PUBLIC

INDIVIDUAL DEVICE ANALYSIS USING HYBRID TEM-SCALPEL

SSRM METROLOGY

UMBERTO CELANO

Senior Researcher

Materials & Components Analysis

[email protected]

Page 2: INDIVIDUAL DEVICE ANALYSIS USING HYBRIDTEM-SCALPEL …

METROLOGY and 3D ARCHITECTURES

HYBRID METROLOGY

“ FLUID CROSS-TECHNIQUES COMPLEMENTARITY ”

Page 3: INDIVIDUAL DEVICE ANALYSIS USING HYBRIDTEM-SCALPEL …

OUTLINE

Scalpel SSRM-TEM

Basic Principles

Applications

and Results

Motivation

Page 4: INDIVIDUAL DEVICE ANALYSIS USING HYBRIDTEM-SCALPEL …

SSRM past and future

Scalpel SPM for 3D tomographic capability

Combining TEM and Scalpel SPM

Sample preparation / Analysis flow

Page 5: INDIVIDUAL DEVICE ANALYSIS USING HYBRIDTEM-SCALPEL …

SSRM past and future

Scalpel SPM for 3D tomographic capability

Combining TEM and Scalpel SPM

Sample preparation / Analysis flow

Page 6: INDIVIDUAL DEVICE ANALYSIS USING HYBRIDTEM-SCALPEL …

6

SSRM BASIC PRINCIPLES

[P. Eyben, et al. Mater. Sci. Eng. B, 124–125, 45–53, 2005]

[K. Mylvaganam, et al., Nanotechnology, 20, 305705, 2009]

[A. Schulze, Ph.D Thesis, KU Leuven, 2013]

Frontiers of Characterization and Metrology for Nanoelectronics 2017

Page 7: INDIVIDUAL DEVICE ANALYSIS USING HYBRIDTEM-SCALPEL …

7

SSRM FOR CONFINED VOLUMES ANALYSIS

Frontiers of Characterization and Metrology for Nanoelectronics 2017

[Vandervorst, W., Mater. Sci. in Semi. Proc., 2016]

Page 8: INDIVIDUAL DEVICE ANALYSIS USING HYBRIDTEM-SCALPEL …

8

FFT-SSRM BASIC PRINCIPLES

Frontiers of Characterization and Metrology for Nanoelectronics 2017

[A. Schulze, et al., Ultramicroscopy, 161, 59–65, 2016]

a(f)

Page 9: INDIVIDUAL DEVICE ANALYSIS USING HYBRIDTEM-SCALPEL …

9

22 YEARS OF NANOELECTRONICS CHARACTERIZATION IN 2D

Frontiers of Characterization and Metrology for Nanoelectronics 2017

SSRM

• Carriers profiling

• Quantification/Calibration

[Nazir, A., et al, IEEE Trans. Electron. Dev., 61, 2014]

[Schulze, A, et al., Nanotechnology, 22(18), 2011]

FFT-SSRM[Vandervorst, W., Mater. Sci. in Semi. Proc., 2016]

Page 10: INDIVIDUAL DEVICE ANALYSIS USING HYBRIDTEM-SCALPEL …

10

22 YEARS OF NANOELECTRONICS CHARACTERIZATION IN 2D

Frontiers of Characterization and Metrology for Nanoelectronics 2017

SSRM

• Carriers profiling

• Quantification/Calibration

[Nazir, A., et al, IEEE Trans. Electron. Dev., 61, 2014]

[Schulze, A, et al., Nanotechnology, 22(18), 2011]

FFT-SSRM[Vandervorst, W., Mater. Sci. in Semi. Proc., 2016]

Page 11: INDIVIDUAL DEVICE ANALYSIS USING HYBRIDTEM-SCALPEL …

11

SCALPEL FOR 3D TOMOGRAPHY

Frontiers of Characterization and Metrology for Nanoelectronics 2017

The transition from 2D to 3D

A stress-assisted chemical reaction Atom-by-atom removal

[Hu, J. et al., Surf. Sci., 237, (1995)] [Xu., M.,W. et al., Appl. Phys. Lett., 81, (2002)]

[Celano, U. et al., IIRW final report, 81, (2014)]

[Celano, U. et al., IEDM Tech. Dig., (2013)]

Page 12: INDIVIDUAL DEVICE ANALYSIS USING HYBRIDTEM-SCALPEL …

12

A SLICE-AND-VIEW APPROACH BY TIP-INDUCED MATERIAL REMOVAL

Frontiers of Characterization and Metrology for Nanoelectronics 2017

Removal performed on: Si, SiGe, Ge, InGaAs, InP, TiN, Cu, Ti,

TaN, Ru, HfO2, SiO2, Al2O3 and Au

[Hantschel, T. et al., Physica Status Solidi (a), 206(9), 2006]

Page 13: INDIVIDUAL DEVICE ANALYSIS USING HYBRIDTEM-SCALPEL …

SSRM past and future

Scalpel SPM for 3D tomographic capability

Combining TEM and Scalpel SPM

Sample preparation / Analysis flow

Page 14: INDIVIDUAL DEVICE ANALYSIS USING HYBRIDTEM-SCALPEL …

15

SCALPEL SSRM APPLICATIONS FOR LOGIC DEVICES

Frontiers of Characterization and Metrology for Nanoelectronics 2017

[Vandervorst, W., Mater. Sci. in Semi. Proc., 2016]

[Celano, U., VLSI-Technology, 2016]

[Celano, U., IEDM Tech. Dig., 2013]

G G G

SiSTI

S DD S

1012 Ω

104 Ω1 µm

G

Page 15: INDIVIDUAL DEVICE ANALYSIS USING HYBRIDTEM-SCALPEL …

16

SCALPEL SSRM APPLICATIONS FOR LOGIC DEVICES

Frontiers of Characterization and Metrology for Nanoelectronics 2017

[Vandervorst, W., Mater. Sci. in Semi. Proc., 2016]

[Celano, U., VLSI-Technology, 2016]

[Celano, U., IEDM Tech. Dig., 2013]

Page 16: INDIVIDUAL DEVICE ANALYSIS USING HYBRIDTEM-SCALPEL …

17

3D TOMOGRAM ANALYSIS CAPABILITY

Frontiers of Characterization and Metrology for Nanoelectronics 2017

Details on a FinFET 22 nm node

Page 17: INDIVIDUAL DEVICE ANALYSIS USING HYBRIDTEM-SCALPEL …

SSRM past and future

Scalpel SPM for 3D tomographic capability

Combining TEM and Scalpel SPM

Sample preparation / Analysis flow

Page 18: INDIVIDUAL DEVICE ANALYSIS USING HYBRIDTEM-SCALPEL …

19

CO-EXISTENCE OF SCALPEL SSRM AND TEM

Frontiers of Characterization and Metrology for Nanoelectronics 2017

[T. Hantschel et al., Physica status solidi (a), 206, (2009)]

[M. Tsigkourakos et al., Carbon, 79, (2014)]

Page 19: INDIVIDUAL DEVICE ANALYSIS USING HYBRIDTEM-SCALPEL …

20

ELECTRON TRANSPARENCY COUPLED WITH MECHANICAL STABILITY

Frontiers of Characterization and Metrology for Nanoelectronics 2017

FIB-induced grid

&

Sample positioning

TEM analysis Scalpel SSRM

Repeat

Page 20: INDIVIDUAL DEVICE ANALYSIS USING HYBRIDTEM-SCALPEL …

Real case study on p-FinFET

Interface between SiGe raised S/D and sGe

Site-specific analysis

metaMetrology

Page 21: INDIVIDUAL DEVICE ANALYSIS USING HYBRIDTEM-SCALPEL …

22

HYBRID METROLOGY: REAL CASE STUDY

Frontiers of Characterization and Metrology for Nanoelectronics 2017

[Mitard

, J.,

VLS

I-T

echnolo

gy,

2016]

Page 22: INDIVIDUAL DEVICE ANALYSIS USING HYBRIDTEM-SCALPEL …

23

INDIVIDUAL DEVICE ANALYSIS SCALPEL-SSRM / TEM

Frontiers of Characterization and Metrology for Nanoelectronics 2017

Page 23: INDIVIDUAL DEVICE ANALYSIS USING HYBRIDTEM-SCALPEL …

24

INTERFACIAL LAYER BETWEEN RAISED S/D SiGe AND Ge

Frontiers of Characterization and Metrology for Nanoelectronics 2017

Page 24: INDIVIDUAL DEVICE ANALYSIS USING HYBRIDTEM-SCALPEL …

25

INTERFACIAL LAYER BETWEEN RAISED S/D SiGe AND Ge

Ge poor interface

Oxygen

out of detection sens.

Frontiers of Characterization and Metrology for Nanoelectronics 2017

Page 25: INDIVIDUAL DEVICE ANALYSIS USING HYBRIDTEM-SCALPEL …

26

SITE-SPECIFIC ANALYSIS UNDER-FIN PARASITIC[Mitard, J., VLSI-Technology, 2015, pp. 1–2]

Frontiers of Characterization and Metrology for Nanoelectronics 2017

Page 26: INDIVIDUAL DEVICE ANALYSIS USING HYBRIDTEM-SCALPEL …

Real case study on p-FinFET

Interface between SiGe raised S/D and sGe

Site-specific analysis

Meta-Metrology

“An abstraction behind another concept, used to complete or add to the latter”

Page 27: INDIVIDUAL DEVICE ANALYSIS USING HYBRIDTEM-SCALPEL …

OUTLOOK AND CONCLUSIONS

Page 28: INDIVIDUAL DEVICE ANALYSIS USING HYBRIDTEM-SCALPEL …

31

CONCLUSIONS

Hybrid metrology

- Scalpel SPM is combined with TEM

- New sample-prep. and workflow is designed

- Local nm-precise, 3D characterization structural / electrical for confined volumes

- Material characterization / Process qualification / Device Failure analysis

Outlook

- Applications to emerging logic devices

- GAA / III-V

- Artifacts correction in SSRM in confined volumes and TEM inspections

Frontiers of Characterization and Metrology for Nanoelectronics 2017

Page 29: INDIVIDUAL DEVICE ANALYSIS USING HYBRIDTEM-SCALPEL …

32

ACKNOWLEDGEMENTS

P. Favia, C. Drijbooms, H. Bender, E. Vancoille

A. Vanderheyden, L. Wouters, K. Paredis, A. Schulze, P. Eyben, R. Loo, A. Hikavyy

J. Mitard, N. Collaert, H. Horiguchi, W. Vandervorst

UMBERTO CELANO

Materials & Components Analysis

[email protected]

Tel: +32 16288656

imec, Kapeldreef 75, B-3001 Leuven, Belgium

Frontiers of Characterization and Metrology for Nanoelectronics 2017

Page 30: INDIVIDUAL DEVICE ANALYSIS USING HYBRIDTEM-SCALPEL …

PUBLIC