SYMBOLS LEGEND INTERIOR ELEVATION SYMBOL COLUMN LOCATION IDENTIFICATION EXTERIOR ELEVATION SYMBOL EXISTING HEIGHT ELEVATION SYMBOL NEW HEIGHT ELEVATION SYMBOL NORTH ARROW FINISH/FIXTURE DRAWING WHERE ELEVATION IS SHOWN DIRECTION WHERE ELEVATION IS VIEWED ROOM NUMBER ROOM NAME ROOM IDENTIFICATION (SEE SCHEDULES) SCHEDULE IDENTIFICATION KEYED GENERAL NOTE MARK (NUMBER) MARK (NUMBER/LETTER) DIRECTION WHERE SECTION IS VIEWED DRAWING WHERE SECTION IS SHOWN BUILDING SECTION SYMBOL DRAWING WHERE SECTION IS SHOWN DIRECTION WHERE SECTION IS VIEWED WALL SECTION SYMBOL ELEVATION IDENTIFICATION DRAWING WHERE ELEVATION IS SHOWN SECTION IDENTIFICATION (NUMBER) SECTION IDENTIFICATION (NUMBER) DETAIL IDENTIFICATION DESCRIPTION ELEVATION IDENTIFICATION DOOR IDENTIFICATION WINDOW IDENTIFICATION DRAWING WHERE DETAIL IS SHOWN MARK (NUMBER) MARK (LETTER) LOCATION OF ELEVATION LOCATION OF ELEVATION DETAIL SYMBOL REVISION IDENTIFICATION MARK (LETTER/NUMBER) MARK (NUMBER) WALL TYPE 0'-0" RATED WALLS 8" CMU WALL CONCRETE PANEL P3 DEMO WALL SYMBOL WALL TO BE REMOVED ONE HOUR FIRE RATED BARRIER MATCH LINE UP or DN STAIR DIRECTION SYMBOL MTL STUD PARTITION WALL W/ BATT INSULATION MTL STUD PARTITION WALL GENERAL NOTES PROJECT SITE PARCEL #: 15-25-18-0000-00300-0000 LOCATION MAP N A. THE INTENT OF THE CONTRACT DOCUMENTS IS TO INCLUDE ALL ITEMS NECESSARY FOR THE PROPER EXECUTION AND COMPLETION OF THE WORK BY THE CONTRACTOR. THE CONTRACT DOCUMENTS ARE COMPLEMENTARY, AND WHAT IS REQUIRED BY ONE SHALL BE AS BINDING AS IF REQUIRED BY ALL; PERFORMANCE BY THE CONTRACTOR SHALL BE REQUIRED ONLY TO THE EXTENT CONSISTENT WITH THE CONTRACT DOCUMENTS AND REASONABLY INFERABLE FROM THEM AS BEING NECESSARY TO PRODUCE THE INTENDED RESULTS. B. ALL CONTRACTORS (GENERAL AND SUB) WILL COORDINATE THEIR WORK PRIOR TO INSTALLATION OF ANY ITEMS SHOWN ON THE DRAWINGS. C. GENERAL CONTRACTOR IS RESPONSIBLE FOR PROVIDING ALL SUBCONTRACTORS ALL NECESSARY INFORMATION. DO NOT GIVE PARTIAL SETS TO SUBCONTRACTORS, AS COORDINATION WILL SUFFER.. D. ALL DRAWINGS WERE PREPARED IN ACCORDANCE WITH THE FLORIDA BUILDING CODE 6TH EDITION 2017. E. THIS IS A PRE-MANUFACTURED BUILDING PROVIDED BY KIRBY BUILDING SYSTEMS. Alteration II BUILDING CODE SUMMARY: III B County State Corporate City City/County Proposed Use: Parcel #: Name of Project: Owned By: Code Enforcement Jurisdiction: Owner or Authorized Agent: Business Construction Type: BUILDING DATA No Sprinklers: YEAR EDITION OF CODE: Yes Repairs Business Occupancy: Pasco County Sheriff's Office Kennel 15-25-18-0000-00300-0000 Livestone Consulting, Inc. FBC 2017 6th Edition, FPC 2017 6th Edition, FMC 2017 6th Edition, Fire Prevention Code 2017 6th Edition, NEC 2014 THESE DRAWINGS WERE PREPARED IN ACCORDANCE WITH AND SHALL COMPLY WITH THE FOLLOWING: 2017 BUILDING CODE, BUILDING, PLUMBING, MECHANICAL TO THE EXTENT REQUIRED BY THE EXISTING BUILDING CODE. 2017 FIRE PREVENTION CODE, 5TH EDITION 2014 NATIONAL ELECTRICAL CODE NFPA 10, 2010 EDITION NFPA 13, 2010 EDITION NFPA 1, 2012 EDITION NFPA 72, 2010 EDITION NFPA 90A, 2012 EDITION NFPA 96, 2011 EDITION NFPA 101, LIFE SAFETY CODE, 2012 EDITION 2017 CODES ARE 6TH EDITION CODE REVIEW PASCO New Construction Private A CODE INFORMATION N/A NOTE: G1.0 Index, Legend and General Notes G1.1 Site Plan G1.2 Life Safety Plans and Notes A1.0 Proposed Floor Plan, Schedules, and Notes A1.1 Proposed Floor Plan and Notes A1.2 Foundation Plan, Wall Types, Details, and Notes A1.3 Lintel Plan, Details, and Notes A1.4 Floor Finish Plan and Notes A2.0 Reflected Ceiling Plan, Schedule, and Notes A2.1 Architectural Electrical Plan and Notes A3.0 Roof Plan, Details, and Notes A4.0 Building Elevations and Notes A4.1 Building Elevations A5.0 Wall Sections A5.1 Wall Section and Key Plan A5.2 Building Sections A6.0 Interior Bathroom Elevations and Key Plan A7.0 Architectural Plumbing Plan and Notes M1.0 Mechanical Sheets M2.0 Mechanical Sheets M3.0 Mechanical Sheets M3.1 Mechanical Sheets E1.0 Electrical Sheets E2.0 Electrical Sheets E3.0 Electrical Sheets E4.0 Electrical Sheets P1.0 Plumbing Sheets P1.1 Plumbing Sheets P2.0 Plumbing Sheets ARCHITECT: LIVESTONE CONSULTING, INC. 2901 W. Busch Blvd., STE. 204, TAMPA, FL 33618 (813) 645-2612 WWW.LIVESTONECONSULTING.COM B INDEX OF DRAWINGS N/A NOTE: D LOCATION INFORMATION N/A NOTE: C NOT USED N/A NOTE: INDEX OF DRAWINGS PROJECT TEAM C 2020 LIVESTONE CONSULTING INC. SEAL SHEET NUMBER REVISIONS PROJECT NUMBER SHEET TITLE DESCRIPTION NO. DATE www.LivestoneConsulting.com GILAD LIVINGSTONE AR 94331 PROJECT PARCEL #: 15-25-18-0000-00300-0000 NEW CONSTRUCTION PASCO COUNTY OWNER L1302130000320 L1302130000317 SHERIFF DEPARTMENT 7220 Osteen Road New Port Richey, FL 34653 2901 W. Busch Blvd., Ste. 204 Tampa, FL 33618 Phone: 813-345-2612 PASCO COUNTY SHERIFF DEPARTMENT DATE ISSUED: REVIEWED BY: GBL DRAWN BY: JEM & JLS DESIGNED BY: JEM 04/14/2020 CANINE KENNEL 1 A0.0 A0.0 A B 1 A0.0 1 A0.0 1 A0.0 C D 1 0'-0" FLOOR ROOM 1 1 1 1 1 1 1 1 G1.0 INDEX, LEGEND, AND GENERAL NOTES SCOPE OF WORK THE CONSTRUCTION OF A BLOCK BUILDING THAT WILL SERVE AS AN OFFICE AND KENNEL BUILDING FOR PASCO SHERIFF CANINE UNIT. THIS BUILDING WILL NOT BE OPEN TO THE PUBLIC AND IS FOR USE BY THE SHERIFF'S DEPARTMENT ONLY. ENGINEER: RENNA ENTERPRISES, INC. 3231 DRANE FIELD ROAD, LAKELAND, FL 33811 (836) 646-1258
29
Embed
INDEX OF DRAWINGS CODE REVIEW SYMBOLS LEGEND · CODE REVIEW PASCO New Construction Private ACODE INFORMATION N/ANOTE: G1.0 Index, Legend and General Notes G1.1 Site Plan G1.2 Life
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
SYMBOLS LEGEND
INTERIOR ELEVATION SYMBOL
COLUMN LOCATION IDENTIFICATION
EXTERIOR ELEVATION SYMBOL
EXISTING HEIGHT ELEVATION SYMBOL
NEW HEIGHT ELEVATION SYMBOL
NORTH ARROW
FINISH/FIXTURE
DRAWING WHERE ELEVATION IS SHOWN
DIRECTION WHERE ELEVATION IS VIEWED
ROOM NUMBER
ROOM NAME
ROOM IDENTIFICATION
(SEE SCHEDULES)
SCHEDULE IDENTIFICATION
KEYED GENERAL NOTE
MARK (NUMBER)
MARK (NUMBER/LETTER)
DIRECTION WHERE SECTION IS VIEWED
DRAWING WHERE SECTION IS SHOWN
BUILDING SECTION SYMBOL
DRAWING WHERE SECTION IS SHOWN
DIRECTION WHERE SECTION IS VIEWED
WALL SECTION SYMBOL
ELEVATION IDENTIFICATION
DRAWING WHERE ELEVATION IS SHOWN
SECTION IDENTIFICATION (NUMBER)
SECTION IDENTIFICATION (NUMBER)
DETAIL IDENTIFICATION
DESCRIPTION
ELEVATION IDENTIFICATION
DOOR IDENTIFICATION
WINDOW IDENTIFICATION
DRAWING WHERE DETAIL IS SHOWN
MARK (NUMBER)
MARK (LETTER)
LOCATION OF ELEVATION
LOCATION OF ELEVATION
DETAIL SYMBOL
REVISION IDENTIFICATION
MARK (LETTER/NUMBER)
MARK (NUMBER)
WALL TYPE
0'-0"
RATED WALLS
8" CMU WALL
CONCRETE PANEL P3
DEMO WALL SYMBOL
WALL TO BE REMOVED
ONE HOUR
FIRE RATED BARRIER
MATCH LINE
UP or DN
STAIR DIRECTION SYMBOL
MTL STUD PARTITION WALL
W/ BATT INSULATION
MTL STUD PARTITION WALL
GENERAL NOTES
PROJECT SITE
PARCEL #:
15-25-18-0000-00300-0000
LOCATION MAP
N
A. THE INTENT OF THE CONTRACT DOCUMENTS IS TO INCLUDE ALL ITEMS NECESSARY FOR THE PROPER EXECUTION AND
COMPLETION OF THE WORK BY THE CONTRACTOR. THE CONTRACT DOCUMENTS ARE COMPLEMENTARY, AND WHAT IS REQUIRED
BY ONE SHALL BE AS BINDING AS IF REQUIRED BY ALL; PERFORMANCE BY THE CONTRACTOR SHALL BE REQUIRED ONLY TO THE
EXTENT CONSISTENT WITH THE CONTRACT DOCUMENTS AND REASONABLY INFERABLE FROM THEM AS BEING NECESSARY TO
PRODUCE THE INTENDED RESULTS.
B. ALL CONTRACTORS (GENERAL AND SUB) WILL COORDINATE THEIR WORK PRIOR TO INSTALLATION OF ANY ITEMS SHOWN ON THE
DRAWINGS.
C. GENERAL CONTRACTOR IS RESPONSIBLE FOR PROVIDING ALL SUBCONTRACTORS ALL NECESSARY INFORMATION. DO NOT GIVE
PARTIAL SETS TO SUBCONTRACTORS, AS COORDINATION WILL SUFFER..
D. ALL DRAWINGS WERE PREPARED IN ACCORDANCE WITH THE FLORIDA BUILDING CODE 6TH EDITION 2017.
E. THIS IS A PRE-MANUFACTURED BUILDING PROVIDED BY KIRBY BUILDING SYSTEMS.
THESE DRAWINGS WERE PREPARED IN ACCORDANCE WITH AND SHALL COMPLY WITH
THE FOLLOWING:
2017 BUILDING CODE, BUILDING, PLUMBING, MECHANICAL
TO THE EXTENT REQUIRED BY THE
EXISTING BUILDING CODE.
2017 FIRE PREVENTION CODE, 5TH EDITION
2014 NATIONAL ELECTRICAL CODE
NFPA 10, 2010 EDITION
NFPA 13, 2010 EDITION
NFPA 1, 2012 EDITION
NFPA 72, 2010 EDITION
NFPA 90A, 2012 EDITION
NFPA 96, 2011 EDITION
NFPA 101, LIFE SAFETY CODE, 2012 EDITION
2017 CODES ARE 6TH EDITION
CODE REVIEW
PASCO
New Construction
Private
A CODE INFORMATION
N/A NOTE:
G1.0 Index, Legend and General Notes
G1.1 Site Plan
G1.2 Life Safety Plans and Notes
A1.0 Proposed Floor Plan, Schedules, and Notes
A1.1 Proposed Floor Plan and Notes
A1.2 Foundation Plan, Wall Types, Details, and Notes
A1.3 Lintel Plan, Details, and Notes
A1.4 Floor Finish Plan and Notes
A2.0 Reflected Ceiling Plan, Schedule, and Notes
A2.1 Architectural Electrical Plan and Notes
A3.0 Roof Plan, Details, and Notes
A4.0 Building Elevations and Notes
A4.1 Building Elevations
A5.0 Wall Sections
A5.1 Wall Section and Key Plan
A5.2 Building Sections
A6.0 Interior Bathroom Elevations and Key Plan
A7.0 Architectural Plumbing Plan and Notes
M1.0 Mechanical Sheets
M2.0 Mechanical Sheets
M3.0 Mechanical Sheets
M3.1 Mechanical Sheets
E1.0 Electrical Sheets
E2.0 Electrical Sheets
E3.0 Electrical Sheets
E4.0 Electrical Sheets
P1.0 Plumbing Sheets
P1.1 Plumbing Sheets
P2.0 Plumbing Sheets
ARCHITECT:
LIVESTONE CONSULTING, INC.
2901 W. Busch Blvd., STE. 204,
TAMPA, FL 33618
(813) 645-2612
WWW.LIVESTONECONSULTING.COM
B INDEX OF DRAWINGS
N/A NOTE:
D LOCATION INFORMATION
N/A NOTE:
C NOT USED
N/A NOTE:
INDEX OF DRAWINGS
PROJECT TEAM
C
2020 LIVESTONE CONSULTING INC.
SEAL
SHEET NUMBER
REVISIONS
PROJECT NUMBER
SHEET TITLE
DESCRIPTIONNO. DATE
www.LivestoneConsulting.com
GILAD LIVINGSTONE
AR 94331
PROJECT
PARCEL #:
15-25-18-0000-00300-0000
NEW CONSTRUCTION
PASCO COUNTY
OWNER
L1302130000320
L1302130000317
SHERIFF DEPARTMENT
7220 Osteen Road
New Port Richey, FL 34653
2901 W. Busch Blvd., Ste. 204
Tampa, FL 33618
Phone: 813-345-2612
PASCO COUNTY
SHERIFF DEPARTMENT
DATE ISSUED:
REVIEWED BY: GBL
DRAWN BY: JEM & JLS
DESIGNED BY: JEM
04/14/2020
CANINE KENNEL
1
A0.0
A0.0
A
B
1
A0.0
1
A0.0
1
A0.0
C
D
1
0'-0"
FLOOR
ROOM
1
1
1
1
1
1
11
G1.0
INDEX, LEGEND,
AND GENERAL
NOTES
SCOPE OF WORK
THE CONSTRUCTION OF A BLOCK BUILDING THAT WILL SERVE AS AN OFFICE AND KENNEL
BUILDING FOR PASCO SHERIFF CANINE UNIT. THIS BUILDING WILL NOT BE OPEN TO THE PUBLIC
AND IS FOR USE BY THE SHERIFF'S DEPARTMENT ONLY.
ENGINEER:
RENNA ENTERPRISES, INC.
3231 DRANE FIELD ROAD,
LAKELAND, FL 33811
(836) 646-1258
AutoCAD SHX Text
CHIPLEY
AutoCAD SHX Text
PANAMA CITY
AutoCAD SHX Text
LAKE CITY
AutoCAD SHX Text
ST AUGUSTINE
AutoCAD SHX Text
GAINESVILLE
AutoCAD SHX Text
BARTOW
AutoCAD SHX Text
TALLAHASSEE
AutoCAD SHX Text
FT. LAUDERDALE
AutoCAD SHX Text
DELAND
AutoCAD SHX Text
DAYTONA BEACH
AutoCAD SHX Text
ORLANDO
AutoCAD SHX Text
TAMPA
AutoCAD SHX Text
WEST PALM BEACH
AutoCAD SHX Text
KEY WEST
AutoCAD SHX Text
SARASOTA
AutoCAD SHX Text
OCALA
AutoCAD SHX Text
LAKE
AutoCAD SHX Text
OKEECHOBEE
AutoCAD SHX Text
PENSACOLA
AutoCAD SHX Text
JACKSONVILLE
AutoCAD SHX Text
ORANGE PARK
AutoCAD SHX Text
QUINCY
AutoCAD SHX Text
PUNTA GORDA
AutoCAD SHX Text
FT. MYERS
AutoCAD SHX Text
N
AutoCAD SHX Text
LAKELAND
AutoCAD SHX Text
CELEBRATION
AutoCAD SHX Text
ST. PETERSBURG
AutoCAD SHX Text
LAND O' LAKES
1 SITE PLAN
NA NOTE:
C
2020 LIVESTONE CONSULTING INC.
SEAL
SHEET NUMBER
REVISIONS
PROJECT NUMBER
SHEET TITLE
DESCRIPTIONNO. DATE
www.LivestoneConsulting.com
GILAD LIVINGSTONE
AR 94331
PROJECT
PARCEL #:
15-25-18-0000-00300-0000
NEW CONSTRUCTION
PASCO COUNTY
OWNER
L1302130000320
L1302130000317
SHERIFF DEPARTMENT
7220 Osteen Road
New Port Richey, FL 34653
2901 W. Busch Blvd., Ste. 204
Tampa, FL 33618
Phone: 813-345-2612
PASCO COUNTY
SHERIFF DEPARTMENT
DATE ISSUED:
REVIEWED BY: GBL
DRAWN BY: JEM & JLS
DESIGNED BY: JEM
04/14/2020
CANINE KENNEL
G1.1
SITE
PLAN
PROPOSED SITE
59 SF
U
3
186 SF
84 SF
U
8
UNOCCUPIED EXTERIOR
ANIMAL STORAGE
1,230 SF
U
1,230 SF
U
1
305 SF
1
305 SF
1
305 SF
1
305 SF
UNOCCUPIED EXTERIOR
ANIMAL STORAGE
67 SF
U
193 SF
U
3
206 SF
3
3
'-5
"
M
A
X
T
R
A
V
E
L
3
2
'
-
2
"
M
A
X
T
R
A
V
E
L
2
27'-5"
MAX TRAVEL
47'-4"
MAX TRAVEL
SEE GENERAL
NOTE #3 (TYP.)
SEE GENERAL
NOTE #3 (TYP.)
SEE GENERAL
NOTE #3 (TYP.)
HW
1 LIFE SAFETY PLAN (OCCUPANT LOAD)
1/8" = 1'-0" NOTE:
C
2020 LIVESTONE CONSULTING INC.
SEAL
SHEET NUMBER
REVISIONS
PROJECT NUMBER
SHEET TITLE
DESCRIPTIONNO. DATE
www.LivestoneConsulting.com
GILAD LIVINGSTONE
AR 94331
PROJECT
PARCEL #:
15-25-18-0000-00300-0000
NEW CONSTRUCTION
PASCO COUNTY
OWNER
L1302130000320
L1302130000317
SHERIFF DEPARTMENT
7220 Osteen Road
New Port Richey, FL 34653
2901 W. Busch Blvd., Ste. 204
Tampa, FL 33618
Phone: 813-345-2612
PASCO COUNTY
SHERIFF DEPARTMENT
DATE ISSUED:
REVIEWED BY: GBL
DRAWN BY: JEM & JLS
DESIGNED BY: JEM
04/14/2020
CANINE KENNEL
G1.2
LIFE SAFETY
PLAN AND
NOTES
DENOTES MAXIMUM LOAD
PER EXTERIOR EGRESS
ELEMENT
ROOM OCCUPANT LOAD
ROOM OCCUPANT LOAD NOT
COUNTED (STORAGE,
HALLWAY, MECH, ETC.)
DENOTES PATH OF
TRAVEL & DISTANCE
DENOTES EMERGENCY EXIT
SIGN WITH BATTERY COMBO
2
U
LIFE SAFETY LEGEND
THE ARCHITECTURAL DRAWINGS ARE IN COMPLIANCE
TO THE BEST OF OUR KNOWLEDGE WITH
THE FOLLOWING CODES AND STANDARDS:
FLORIDA BUILDING CODE - BUILDING 2017, 6TH
EDITION
FLORIDA BUILDING CODE - PLUMBING 2017, 6TH
EDITION
FLORIDA BUILDING CODE - FUEL GAS 2017, 6TH
EDITION
FLORIDA BUILDING CODE - MECHANICAL 2017, 6TH
EDITION
FLORIDA BUILDING CODE - ACCESSIBILITY 2017, 6TH
EDITION
NATIONAL ELECTRICAL CODE - 2014 EDITION
NFPA 101 LIFE SAFETY CODE W/ FLORIDA
MODIFICATIONS - 2015 EDITION
ASHRAE (STANDARD 90.1) - 2010 EDITION
FLORIDA FIRE PREVENTION CODE - 2014, 5TH EDITION
CLASSIFICATION OF WORK: NEW CONSTRUCTION
CONSTRUCTION TYPE: TYPE IIIB, NOT
SPRINKLED
AREA LIMITATION: 19,000 SF PER STORY
HEIGHT LIMITATION: 3 STORIES, 55' MAX.
PROPOSED HEIGHT: 23'-4"
NUMBER OF FLOORS: 1 STORY
OCCUPANCY CLASSIFICATION: BUSINESS GROUP B
(PER FBC 304.1)
PROPOSED AREA (CONDITIONED) :
3,120 SF
PROPOSED AREA (UN-CONDITIONED) :
2,460 SF
GROSS AREA (UNDER ROOF) :
5,667 SF
PROPOSED FACILITY OCCUPANT LOAD: 83 PERSONS
PROPOSED # OF OUTDOOR FIXED SEATS: 0
EGRESS WIDTH:
OCCUPANT LOAD: 6 PERSONS
DOOR WIDTH REQUIRED: 1.2" (6 @ .2" PER
PERSON)
DOOR WIDTH PROVIDED: 28.8" (1,320 PERSONS)
MAXIMUM ALLOWABLE EXIT
ACCESS TRAVEL DISTANCE: 250' (W/O
SPRINKLER
SYSTEM)
MAXIMUM TRAVEL DISTANCE: 47' -45"
MIN. # OF EXITS FOR OCCUPANT LOAD: 2 (1-500
PERSONS)
# OF EXITS PROVIDED: 2
LIFE SAFETY GENERAL NOTES
GENERAL NOTES:
1. POST TACTILE SIGNAGE AS REQUIRED AT ALL
MEANS OF EGRESS; REF. 3/G1.1.
2. PROVIDE FIRE EXTINGUISHERS, TYPE ABC,
WALL HUNG, TOP AT 5'-0" A.F.F. (BY GENERAL
CONTRACTOR); MU,BER AND LOCATIONS AS
REQUIRED BY LOCAL CODE.
THE GENERAL CONTRACTOR SHALL ACQUAINT HIMSELF WITH THE
BARRIER FREE REQUIREMENTS FOR THE APPLICABLE STATES
AND THE AMERICAN DISABILITIES ACT (ADA) AND SHALL ENSURE
THAT THIS FACILITY WILL BE ACCESSIBLE ACCORDING TO THE
STRICTER REQUIREMENTS OF THE APPLICABLE STANDARDS. THE
FOLLOWING IS A PARTIAL LIST OF REQUIREMENTS.
1. DOOR HARDWARE SHALL BE MOUNTED BETWEEN 36" AND 42"
ABOVE FLOOR AND BE LEVER TYPE.
2. TOILETS:
A. LAVATORY TO HAVE LEVER HANDLES, SELF
METERING FAUCETS OR SPRING FAUCET. FAUCETS
SHALL BE SET TO REMAIN OPEN FOR 10 SECONDS
MINIMUM.
B. LOCATE THE WATER CLOSET 16" TO 18" FROM THE
CENTER LINE OF THE FIXTURE TO THE WALL. THE
SEAT WILL BE 17" TO 19" ABOVE THE FLOOR TO THE
TOP OF SEAT. FLUSH HANDLE TO BE ON EXPOSED
SIDE OF WATER CLOSET.
C. PROVIDE ONE 42" AND ONE 36" LONG x 1 1/2" OUTSIDE
DIAMETER PEENED GRAB BARS, 1 1/2" FROM THE
WALL WITH ONE BEHIND AT 12" FROM CENTER LINE OF
WATER CLOSET ON ONE SIDE. ONE ADJACENT TO AT
12" FROM THE WALL 33"-36" PARALLEL TO AND ABOVE
THE FLOOR.
D. LAVATORY TO BE MOUNTED 34" MAX. ABOVE THE
FINISHED FLOOR TO RIM WITH KNEE SPACE OF 30" IN
WIDTH AND 27" IN CLEAR HEIGHT. (29" CLEAR UNDER
FRONT EDGE).
E. INSTALL MIRROR 40" MAX. ABOVE THE FINISHED
FLOOR TO BOTTOM EDGE OF REFLECTING SURFACE
(MIRROR GLASS BOTTOM) AND 72" TO TOP.
F. TOILET PAPER DISPENSERS MOUNTED 19" MIN. TO
CENTER LINE ABOVE THE FLOOR AND 7" MINIMUM AND
9" MAXIMUM FROM FRONT EDGE OF WATER CLOSET
MEASURED TO THE CENTERLINE OF THE DISPENSER.
ADA NOTES:
NFPA OCCUPANCY LOAD FACTOR:
USE SF / PERSON AREA OCCUPANTS
BUSINESS 100 GROSS 416 SF 5
STORAGE (GENERAL) 500 GROSS 277 SF 1
ANIMAL STORAGE 500 GROSS 2,432 SF 5
TOTAL: 11
ALL OCCUPANT FACTORS ARE BASED OFF NFPA 101: TABLE 7.3.1.2
2 LIFE SAFETY PLAN (A.D.A CLEARANCES)
1/8" = 1'-0" NOTE:
3 ADA SIGNAGE DETAIL
N.T.S. NOTE: THIS DETAIL IS FOR REFERENCE ONLY; ADA SIGNAGE SHALL COMPLY WITH ALL APPLICABLE CODES
GENERAL CONTRACTOR TO VERIFY EXISTING SIGNAGE IN FIELD AND PROVIDE NEW AS REQUIRED TO COMPLY WITH APPLICABLE BUILDING CODES.
ALL SIGNAGE SHALL CONFORM WITH ADA ACCESSIBILITY GUIDELINES, INCLUDING BUT NOT LIMITED TO PROPORTION, COLOR CONTRAST AND RELIEF AND GRADE 2 BRAILLE REQUIREMENTS.
SIGNAGE: AFFIX AN INTERNATIONAL ACCESSIBILITY SYMBOL ON ALL ACCESSIBLE ENTRANCES PER APPLICABLE BUILDING CODE.
STRIKE EDGE CLEARANCE AT DOORWAY:PROVIDE AN 18" STRIKE EDGE CLEARANCE ON THE PULL SIDE OF INTERIOR DOORS.PROVIDE A 24" STRIKE EDGE CLEARANCE ON THE PULL SIDE OF THE EXTERIOR DOORS.PROVIDE A 12" STRIKE EDGE CLEARANCE ON THE PUSH SIDE OF ALL DOORS WHICH HAVE BOTH A LATCH AND A CLOSER.
TACTILE EXIT SIGNAGE:A TACTILE EXIT SIGN WITH THE WORD "EXIT" SHALL IDENTIFY EACH GRADE LEVEL EXTERIOR EXIT DOOR.A TACTILE EXIT SIGN WITH THE WORDS "EXIT ROUTE" SHALL IDENTIFY EACH EXIT ACCESS DOOR FROM AN INTERIOR ROOM OR AREA TO A CORRIDOR OR HALLWAY THAT IS REQUIRED TO HAVE A VISUAL EXIT SIGN.GENERAL CONTRACTOR TO VERIFY EXISTING SIGNAGE INSTALLATIONS AND PROVIDE NEW AS REQUIRED.CHARACTERS, SYMBOLS AND BACKGROUND SHALL HAVE A NON-GLARE FINISH.CHARACTERS AND SYMBOLS SHALL CONTRAST WITH THE BACKGROUND, EITHER LIGHT ON DARK BACKGROUND OR DARK ON LIGHT BACKGROUND.SIGNS TO INCLUDE BRAILLE AND CHARACTERS AS DEFINED BY CODE.MOUNT SIGNAGE AT 60" A.F.F. TO THE CENTER OF THE SIGN. MOUNTING LOCATION SHALL BE SO THAT A PERSON APPROACHING WITHIN 3" OF SIGN DOES NOT ENCOUNTER PROTRUDING OBJECTS OR WITHIN THE SWING OF ADOOR.
2. ALL FLOORING SHOWN IS BASIS OF DESIGN. GENERAL CONTRACTOR IS TO
VERIFY THE FINAL FLOORING WITH THE ARCHITECT BEFORE INSTALLATION.
3. ALL FLOORING IN RESTROOM AND DOG RUN AREA ARE TO BE RATED FOR WET
USE
AutoCAD SHX Text
N
LED-5 LED-5 LED-5
LED-5LED-5LED-5
LED-5 LED-5 LED-5
LED-5
LED-5
LED-5
LED-5
LED-5
LED-5
LED-5
LED-5
LED-5
LED-5
LED-5
LED-5
LED-5 LED-5 LED-5
LED-5LED-5LED-5
LED-5 LED-5 LED-5
LED-4
LED-4
LED-6 LED-6
LED-6
LED-6
LE
D-6
LE
D-6
LE
D-6
LE
D-6
LED-6LED-6
LED-6
LED-6
LE
D-6
LE
D-6
LE
D-6
LE
D-6
LE
D-6
LE
D-6
O.C.
O.C.
O.C.
O.C.
O.C.
D.S.
1
1
1
1
2
S
S
S
EE
O.C.
1
O.C.
1
FL
FL
FL
EE
EE
D.S.
O.C.
2
FL
FL
C
2020 LIVESTONE CONSULTING INC.
SEAL
SHEET NUMBER
REVISIONS
PROJECT NUMBER
SHEET TITLE
DESCRIPTIONNO. DATE
www.LivestoneConsulting.com
GILAD LIVINGSTONE
AR 94331
PROJECT
PARCEL #:
15-25-18-0000-00300-0000
NEW CONSTRUCTION
PASCO COUNTY
OWNER
L1302130000320
L1302130000317
SHERIFF DEPARTMENT
7220 Osteen Road
New Port Richey, FL 34653
2901 W. Busch Blvd., Ste. 204
Tampa, FL 33618
Phone: 813-345-2612
PASCO COUNTY
SHERIFF DEPARTMENT
DATE ISSUED:
REVIEWED BY: GBL
DRAWN BY: JEM & JLS
DESIGNED BY: JEM
04/14/2020
CANINE KENNEL
A2.0
REFLECTED
CEILING PLAN
AND NOTES
GENERAL NOTES:
1. ALL FIXTURES, INCLUDING FURNITURE, ARE TO BE PROVIDED BY OWNER UNLESS
OTHERWISE SPECIFIED.
2. INTERNAL DIMENSIONS ARE FROM CENTER OF WALL.
3. PROVIDE OCCUPANCY CENSOR, DAYLIGHT SENSOR, AND SMOKE DETECTORS AS
REQUIRED BY CODE.
4. ALL CEILINGS TO BE 10'-0" A.F.F. UNLESS OTHERWISE NOTED.
5. ALL LIGHTING SHOWN IS FOR REFERENCE ONLY; REFER TO ELECTRICAL DRAWING BY
ENGINEER FOR MORE INFORMATION.
1 REFLECTED CEILING PLAN
3/16"-1'-0" NOTE:
LEGEND:
EXHAUST FAN
SSMOKE DETECTOR
LED-4
LED-6
2 X 4 LED TROFFER LIGHT
2 X 2 LED TROFFER LIGHT
EMERGENCY EXIT
SIGN / LIGHT COMBO
FLOOD LIGHT
O.C.1
O.C.2
D.S.
OCCUPANCY CENSOR
INFRARED OCCUPANCY DETECTOR
DAYLIGHT SENSOR
LED-5
1 X 4 LED W.P. LIGHT FIXTURE
2 X 2 DROP CEILING GRID
TYPE X GYP. WITH APOXI FINISH
LIGHTING SCHEDULE:
DESCRIPTION MANUFACTURER
LIGHTING SCHEDULE
CODE MODEL # REMARKS
1. PROVIDE ALL FIXTURES COMPLETE WITH LAMPS
2. PROVIDE ALL REQUIRED MOUNTING OR HANGING HARDWARE
3. THE QUANITIES SHOWN IN THE LIGHTING SCHEDULE ARE BASED ON THE NUMBER OF FIXTURES SHOWN IN THE CONSTRUCTION DOCUMENTS; REFER TO GENERAL NOTE #2 ON SHEET A2.1
NOTES:
OC 1 CEILING SENSOR LOW VOLTAGE BY PIR SWITCH MOTION DETECTOR, OCCUPANCY SENSOR
MOUNT, CEILING LIGHT SENSOR, WHITE
ENERLITES MPC-50L-STICKER
LED-6 2' X 4' 128-WATT EQUIVALENT WHITE VOLUMETRIC INTEGRATED LED COMMERCIAL GRID CEILING
TROFFER
ENVIROLITE EVTR24DI42WD VERIFY INSTALLATION WITH OWNER
COMBO 14-WATT WITH NICAD 9.6 VOLT BATTERY WHITE INTEGRATED LED EXIT SIGN AND
EMERGENCY LIGHT
COMMERCIAL ELECTRIC EECLEDRG120277
QUANTITIES
6
16
3
LED-4 2' X 2' LED VOLUMETRIC WHITE TROFFER LIGHT ENVIROLITE EVTR22DI23WD VERIFY INSTALLATION WITH OWNER2
LED-5 1' X 4' LED SURFACE MOUNT TROFFER, 32, 48, OR 57 WATT SAYLITE 153A14 VERIFY INSTALLATION WITH OWNER30
D.S. 1800-WATT OUTDOOR STEM MOUNT SWIVEL ADJUSTABLE DUSK-TP-DAWN LIGHT CONTROL DEFIANT EZ-352A 2
OC 2 360 PASSIVE INFRARED OCCUPANCY SENSOR FIXTURE MOUNT HIGH BAY LITHONIA LIGHTING CMRB-6 2
EE
FL
EE
GOOD EARTH LIGHTING 6.25-IN 2-HEAD LED WHITE SWITCH-CONTROLLED FLOOD LIGHT GOOD EARTH LIGHTING SE1092-WH3-00LF0-G 3
FL
S CODE ONE 10-YEAR SEALED BATTERY SMOKE DETECTOR WITH IONIZATION SENSOR KIDDE 21009992 3
2 NOT USED
N/A NOTE:
AutoCAD SHX Text
N
3
S3
GF
IG
FI
S
SS
S
3
S
S
S3
S3
S3
S
GFI GFI
WP
GFI GFI
WP
WP WP
S
S
S3
S3
S3
S3
S3
S
3
LED-5 LED-5 LED-5
LED-5LED-5LED-5
LED-5 LED-5 LED-5
LED-5
LED-5
LED-5
LED-5
LED-5
LED-5
LED-5
LED-5
LED-5
LED-5
LED-5
LED-5
LED-5 LED-5 LED-5
LED-5LED-5LED-5
LED-5 LED-5 LED-5
LED-4
LED-4
LED-6 LED-6
LED-6
LED-6
LE
D-6
LE
D-6
LE
D-6
LE
D-6
LED-6LED-6
LED-6
LED-6
LE
D-6
LE
D-6
LE
D-6
LE
D-6
LE
D-6
LE
D-6
FL
FL
FL
FL
FL
WP
/A
CW
P/A
C
C
2020 LIVESTONE CONSULTING INC.
SEAL
SHEET NUMBER
REVISIONS
PROJECT NUMBER
SHEET TITLE
DESCRIPTIONNO. DATE
www.LivestoneConsulting.com
GILAD LIVINGSTONE
AR 94331
PROJECT
PARCEL #:
15-25-18-0000-00300-0000
NEW CONSTRUCTION
PASCO COUNTY
OWNER
L1302130000320
L1302130000317
SHERIFF DEPARTMENT
7220 Osteen Road
New Port Richey, FL 34653
2901 W. Busch Blvd., Ste. 204
Tampa, FL 33618
Phone: 813-345-2612
PASCO COUNTY
SHERIFF DEPARTMENT
DATE ISSUED:
REVIEWED BY: GBL
DRAWN BY: JEM & JLS
DESIGNED BY: JEM
04/14/2020
CANINE KENNEL
A2.1
ARCHITECTURAL
ELECTRICAL PLAN
AND NOTES
1 ELECTRICAL PLAN
1/4" = 1'-0" NOTE:
ELECTRICAL LEGEND:
GFI
S
OC1
S3
DUPLEX RECEPTACLE
S
SMOKE DETECTOR
EXHAUST FAN
OCCUPANCY SENSOR
THREE-WAY SWITCH
SINGLE-POLE SWITCH
GROUND FAULT INTERRUPTED DUPLEX RECEPTACLE
GENERAL NOTES:
1. GENERAL CONTRACTOR'S ELECTRICIAN TO PROVIDE COMPLETED DRAWINGS AND CALCULATIONS REQUIRED
BY THE AUTHORITY HAVING JURISDICTION.
2. GENERAL CONTRACTOR'S ELECTRICAL SUB-CONTRACTOR TO PROVIDE PANEL SCHEDULE AND ALL REQUIRED
DOCUMENTATION TO THE AUTHORITY HAVING JURISDICTION.
3. THE POWER SHOWN IS FOR GENERAL LOCATION PURPOSES ONLY; CONTRACTOR TO PROVIDE SUFFICIENT
SERVICE AND CIRCUIT LOADING TO ALL ELECTRICAL DEVICES.
4. COORDINATE ALL LIGHTING WITH HVAC SO THERE IS NO CONFLICT.
5. GENERAL CONTRACTOR TO INSTALL ALL CEILING OUTLETS WITH WATER PROOF BACKERS.
6. ALL EXTERIOR LIGHTING IS TO BE ON DAYLIGHT SENORES U.N.O.
7. ALL ELECTRICAL SHOWN IS FOR REFERENCE ONLY; REFER TO ELECTRICAL DRAWING BY ENGINEER FOR
MORE INFORMATION INCLUDING BUT NOT LIMITED TO; CALCS, DIAGRAMS, PANEL SCHEDULE ETC.
8. OUTLETS LOCATED IN CEILING ARE TO BE A PULL-DOWN SELF RETRACTING OUTLET; GENERAL CONTRACTOR
TO PROVIDE.
2 NOT USED
N/A NOTE:
WEATHER PROOF OUTLET
WP
GFI
GROUND FAULT INTERRUPTED MOUNTED CEILING HEIGHT
OC2INFRARED OCCUPANCY SENSOR
D.S.DAYLIGHT SENSOR
WEATHER PROOF OUTLET FOR HVAC UNIT
WP/AC
AutoCAD SHX Text
N
SL
OP
E
SL
OP
E
SL
OP
E
SL
OP
E
SL
OP
E
SL
OP
E
SL
OP
E
SL
OP
ES
LO
PE
SL
OP
E
SL
OP
E
SL
OP
E
SL
OP
E
SL
OP
E
SL
OP
ES
LO
PE
RIDGE VENTS
2'-0"
2'-0"
4' 4' 4' 4'
24" O.C.
TYPICAL
AIR
AIR
A
IR
V-600TE
RIDGE SLOT
METAL FLASHING
METAL BRACE
RIDGE CAP
STANDING SEAM METAL ROOFING
UNDERLAYMENT
SHEATHING
1" AIR SLOT
PRE-ENGINEERED P.T. WOOD TRUSSES
2" CLEARANCE FOR VENTILATION
C
2020 LIVESTONE CONSULTING INC.
SEAL
SHEET NUMBER
REVISIONS
PROJECT NUMBER
SHEET TITLE
DESCRIPTIONNO. DATE
www.LivestoneConsulting.com
GILAD LIVINGSTONE
AR 94331
PROJECT
PARCEL #:
15-25-18-0000-00300-0000
NEW CONSTRUCTION
PASCO COUNTY
OWNER
L1302130000320
L1302130000317
SHERIFF DEPARTMENT
7220 Osteen Road
New Port Richey, FL 34653
2901 W. Busch Blvd., Ste. 204
Tampa, FL 33618
Phone: 813-345-2612
PASCO COUNTY
SHERIFF DEPARTMENT
DATE ISSUED:
REVIEWED BY: GBL
DRAWN BY: JEM & JLS
DESIGNED BY: JEM
04/14/2020
CANINE KENNEL
A3.0
ROOF AND TRUSS
PLAN AND
NOTES
1 ROOF PLAN
1/8" = 1'-0" NOTE:
2 TRUSS PLAN
1/8" = 1'-0" NOTE:
ROOFING NOTES:
1. UNDERLAYMENT TO BE GRACE ICE AND WATER SHIELD OR EQUAL.
2. FASTEN
5
8
" APA RATED ROOF SHEATHING TO ROOF TRUSS MEMBERS W/10d COMMON NAILS @
4" O.C. ALONG PANEL EDGES, @12" O.C. ALONG INT SUPPORTS.
3. TRUSS MANUFACTURER TO MEET WIND PRESSURE CRITERIA FOR 145 MPH WIND ZONE.
4. SEE ELEVATIONS FOR ROOF SLOPES.
5. ROOF TO BE STANDING SEAM METAL ROOFING.
6. ROOF VENTS TO BE PLACED ALONG ALL ROOF RIDGES WITH MINIMUM 4'-0" CLEARANCE;
GENERAL CONTRACTOR TO INSTALL ROOF VENTS PER MANUFACTURES INSTRUCTIONS.
7. GENERAL CONTRACTOR TO TIE ALL TRUSSES INTO BLOCK PER FBC 2017 6TH EDITION
STANDARD.
4 NOT USED
N/A NOTE:
3 RIDGE VENT DETAIL (TYP.)
3" = 1'-0" NOTE: THIS DETAIL IS FOR REFERENCE ONLY; GENERAL CONTRACTOR TO INSTALL PER MANUFACTURES INSTRUCTIONS
AutoCAD SHX Text
N
AutoCAD SHX Text
N
1" X 2" P.T. WOOD TRIM
@ 18" O.C.
SOFFIT
STUCCO WITH STONE FINISH;
CAP @ 36"
10
'-0" C
EIL
IN
G H
EIG
HT
23
'-4
"
ATTIC VENT
1X4 P.T. WOOD TRIM
21
'-7
"
12"
8"
STUCCO
STONE TRIM AROUND
WINDOWS AND DOORS
4'-6
"
5'
7'-8
"
2'-8
"
3'-4
"
6'-8
"
STANDING SEAM METAL ROOF
CHAIN FENCE
10
'-0
" C
EIL
IN
G H
EIG
HT
RIDGE VENT
21
'-7
"
23
'-4
"
STUCCO WITH STONE
FINISH; CAP @ 36"
STUCCO
STANDING SEAM METAL ROOF
STUCCO
2'-8
" T
O S
IL
L5
'
7'-8
" H
EA
DE
R
4'
4" WOOD TRIM;
PAINT WHITE U.N.O.
NOTE:
ALL WINDOWS ARE OF THE SAME SIZE AND
STYLE; FINAL STYLE TO BE PER OWNER
C
2020 LIVESTONE CONSULTING INC.
SEAL
SHEET NUMBER
REVISIONS
PROJECT NUMBER
SHEET TITLE
DESCRIPTIONNO. DATE
www.LivestoneConsulting.com
GILAD LIVINGSTONE
AR 94331
PROJECT
PARCEL #:
15-25-18-0000-00300-0000
NEW CONSTRUCTION
PASCO COUNTY
OWNER
L1302130000320
L1302130000317
SHERIFF DEPARTMENT
7220 Osteen Road
New Port Richey, FL 34653
2901 W. Busch Blvd., Ste. 204
Tampa, FL 33618
Phone: 813-345-2612
PASCO COUNTY
SHERIFF DEPARTMENT
DATE ISSUED:
REVIEWED BY: GBL
DRAWN BY: JEM & JLS
DESIGNED BY: JEM
04/14/2020
CANINE KENNEL
A4.0
EXTERIOR
ELEVATIONS
AND NOTES
1 EAST ELEVATION
1/4"=1'-0" NOTE:
1 SOUTH ELEVATION
1/4"=1'-0" NOTE:
GENERAL NOTES:
1. ALL EXTERIOR WALLS FINISHES/ COLORS IS PER OWNER;
GENERAL CONTRACTOR TO VERIFY BEFORE ORDERING.
2. EXTERIOR FINISHES SHOWN ARE BASIS OF DESIGN, FINAL
FINISHES MAY VARY.
2 TYPICAL WINDOW DIAGRAM
1/2" = 1'-0" NOTE:
12"
8"
ATTIC VENT
1" X 2" P.T. WOOD TRIM
@ 18" O.C.
SOFFIT
1X4 P.T. WOOD TRIM
STUCCO WITH STONE
FINISH; CAP @ 36"
STUCCO
6'-8"
3'-6
"
10'-0
" C
EIL
IN
G H
EIG
HT
23
'-4"
STANDING SEAM METAL ROOF
CHAIN FENCE
10
'-0
" C
EIL
IN
G H
EIG
HT
RIDGE VENT
21
'-7"
23'-4"
STUCCO WITH STONE
FINISH; CAP @ 36"
STUCCO
STUCCO
STANDING SEAM METAL ROOF
C
2020 LIVESTONE CONSULTING INC.
SEAL
SHEET NUMBER
REVISIONS
PROJECT NUMBER
SHEET TITLE
DESCRIPTIONNO. DATE
www.LivestoneConsulting.com
GILAD LIVINGSTONE
AR 94331
PROJECT
PARCEL #:
15-25-18-0000-00300-0000
NEW CONSTRUCTION
PASCO COUNTY
OWNER
L1302130000320
L1302130000317
SHERIFF DEPARTMENT
7220 Osteen Road
New Port Richey, FL 34653
2901 W. Busch Blvd., Ste. 204
Tampa, FL 33618
Phone: 813-345-2612
PASCO COUNTY
SHERIFF DEPARTMENT
DATE ISSUED:
REVIEWED BY: GBL
DRAWN BY: JEM & JLS
DESIGNED BY: JEM
04/14/2020
CANINE KENNEL
A41
EXTERIOR
ELEVATIONS
AND NOTES
1 WEST ELEVATION
1/4"=1'-0" NOTE:
1 NORTH ELEVATION
1/4"=1'-0" NOTE:
2 NOT USED
N/A NOTE:
2'-9"
5'-6"
10'-0"
DAMP PROOFING /
VAPOR BARRIER
CONT. METAL
FLASHING WITH
BACKER ROD AND
SEALANT
SIMPSON HETA 20
UNDERLAYMENT
1
2
" EXTERIOR GRADE
PLYWOOD
TRUSS
STANDING SEAM
METAL ROOFING
CONTINUOUS METAL
FLASHING
PGT WINDOW (TYP.);
FINISH TO BE
BRONZE - INSTALL
PER
MANUFACTURER'S
RECOMMENDATIONS;
OLDCASTLE ALL
CAST-FIT
WATERTABLE/SILL,
TAUPE (TYP.);
SOURCE THROUGH
OWNER
CONT. METAL
FLASHING WITH
SEALANT
HORIZONTAL JOINT
REINFORCEMENT @
16" O.C.
CONTINUOUS METAL
FLASHING
DAMP PROOFING /
VAPOR BARRIER
LAP SIDING OR VINYL
CLADDING INSTALL
WHERE APPLICABLE;
INSTALL PER
MANUFACTURER'S
RECOMMENDATION
(SEE ELEVATIONS
FOR MORE
INFORMATION)
8" K.O. BLOCK W/ (1)
#5 CONT. FULLY
GROUTED
1x PT WOOD
FURRING
5
8
" TYPE X GYPSUM
WALL BOARD
3
4
" PT PLYWOOD
SUBSTRATE
R-30 INSULATION
8" CMU BLOCK W/ #5
VERT.
@ 32" O.C.;
ALTERNATE
SIDES
5
8
" GYPSUM WALL
BOARD
1x PT WOOD
FURRING
FINISHED WALL
BEYOND
LINTEL TYPE L-4;
SEE LINTEL
SCHEDULE
VENTED SOFFIT
COMPACTED EARTH;
COMPACT TO 90%
PROCTOR
FINISH WALL BEYOND
10 MIL. VAPOR
RETARDER
SEE FOOTER DETAIL
5/A1.2 FOR MORE
INFORMATION
10'-0"
8" CMU BLOCK W/ #5
VERT. @ 32" O.C.;
ALTERNATE SIDES
1x PT WOOD
FURRING
4" SLAB WITH W.W.F.
CONTINUOUS METAL
FLASHING
4" CONCRETE SLAB
WITH #4 W.W.F.
CENTERED
1
2
" CONTROL JOINT
STUCCO FINISH;
PAINT PER OWNER'S
REQUIREMENTS
LATH
DAMP PROOFING /
VAPOR BARRIER
UNDERLAYMENT
1
2
" EXTERIOR GRADE
PLYWOOD
TRUSS
STANDING SEAM
METAL ROOFING
CONTINUOUS METAL
FLASHING
3
4
" PT PLYWOOD
SUBSTRATE
PRE-ENGINEERED PT
WOOD TRUSSES
R-30 INSULATION
8" K.O. BLOCK W/ (1)
#5 CONT. FULLY
GROUTED
5
8
" GYPSUM WALL
BOARD; ORANGE
PEEL FINISH
1x PT WOOD
FURRING
1
2
STUCCO; SEE
ELEVATIONS A4.0
FOR MORE
INFORMATION
VENTED SOFFIT
SIMPSON HETA 20
10 MIL. VAPOR
RETARDER
SEE FOOTER DETAIL
5/A1.2 FOR MORE
INFORMATION
COMPACTED EARTH;
COMPACT TO 90%
PROCTOR
5
8
" TYPE X GYPSUM
WALL BOARD
C
2020 LIVESTONE CONSULTING INC.
SEAL
SHEET NUMBER
REVISIONS
PROJECT NUMBER
SHEET TITLE
DESCRIPTIONNO. DATE
www.LivestoneConsulting.com
GILAD LIVINGSTONE
AR 94331
PROJECT
PARCEL #:
15-25-18-0000-00300-0000
NEW CONSTRUCTION
PASCO COUNTY
OWNER
L1302130000320
L1302130000317
SHERIFF DEPARTMENT
7220 Osteen Road
New Port Richey, FL 34653
2901 W. Busch Blvd., Ste. 204
Tampa, FL 33618
Phone: 813-345-2612
PASCO COUNTY
SHERIFF DEPARTMENT
DATE ISSUED:
REVIEWED BY: GBL
DRAWN BY: JEM & JLS
DESIGNED BY: JEM
04/14/2020
CANINE KENNEL
A5.0
BUILDING
SECTIONS
AND NOTES
1 WALL SECTION
1-1/2"=1'-0" NOTE:
2 WALL SECTIONS
1-1/2"=1'-0" NOTE:
10'-0"
CONTINUOUS METAL
FLASHING
4" CONCRETE SLAB
WITH #4 W.W.F.
CENTERED
1
2
" CONTROL JOINT
STUCCO FINISH;
PAINT PER OWNER'S
REQUIREMENTS
5
8
" EXTERIOR GRADE
GYPSUM WALL
BOARD
DAMP PROOFING /
VAPOR BARRIER
SIMPSON HETA 20
UNDERLAYMENT
1
2
" EXTERIOR GRADE
PLYWOOD
TRUSS
STANDING SEAM
METAL ROOFING
CONTINUOUS METAL
FLASHING
3
4
" PT PLYWOOD
SUBSTRATE
PRE-ENGINEERED PT
WOOD TRUSSES
R-30 INSULATION
CHAIN FENCE
ASSEMBLY
VENTED SOFFIT
DAMP PROOFING /
VAPOR BARRIER
STUCCO FINISH
2X6 P.T. WOOD TRIM
CONT. METAL DRIP
EDGE WITH BACKER
ROD AND SEALANT;
BOTH SIDES
(3) 2X12 GLULAM
BEAMS BUCKETED
AT EACH END
4" SLAB WITH W.W.F.
10 MIL. VAPOR
RETARDER
SEE FOOTER DETAIL
5/A1.2 FOR MORE
INFORMATION
COMPACTED EARTH;
COMPACT TO 90%
PROCTOR
1
A5.1
1
A5.2
2
A5.2
1
A5.0
2
A5.0HW
3
A5.1
(3) 2X12 GLULAM
BEAMS
TRUSSES ABOVE WITH
SIMPSON HETA20 STRAPS;
SEE WALL SECTIONS ON A5.0
FOR MORE INFORMATION
LAG BOLT W/ 3"
CLEAR @ 16" O.C.
STAGGERED
CMU BLOCK COLUMN
SIMPSON HU28-4
C
2020 LIVESTONE CONSULTING INC.
SEAL
SHEET NUMBER
REVISIONS
PROJECT NUMBER
SHEET TITLE
DESCRIPTIONNO. DATE
www.LivestoneConsulting.com
GILAD LIVINGSTONE
AR 94331
PROJECT
PARCEL #:
15-25-18-0000-00300-0000
NEW CONSTRUCTION
PASCO COUNTY
OWNER
L1302130000320
L1302130000317
SHERIFF DEPARTMENT
7220 Osteen Road
New Port Richey, FL 34653
2901 W. Busch Blvd., Ste. 204
Tampa, FL 33618
Phone: 813-345-2612
PASCO COUNTY
SHERIFF DEPARTMENT
DATE ISSUED:
REVIEWED BY: GBL
DRAWN BY: JEM & JLS
DESIGNED BY: JEM
04/14/2020
CANINE KENNEL
A5.1
BUILDING
SECTIONS
AND NOTES
1 WALL SECTION
3/4"=1'-0" NOTE:
2 KEY PLAN
1/8"=1'-0" NOTE:
3 GLULAM AND COLUMN CONNECTION DETAIL (TYP.)
1-1/2"=1'-0" NOTE:
23'-4"
10'
1X4 P.T. WOOD TRIM
STANDING SEAM METAL ROOF
R-30
INSULATION
8" CMU BLOCK W/ #5 VERT.
@ 32" O.C.; ALTERNATE SIDES
5
8
" GYPSUM WALL BOARD;
ORANGE PEEL FINISH
4" CONCRETE SLAB
WITH #4 W.W.F.
CENTERED
SOFFIT
2X4 WOOD FACE
2X4 P.T. WOOD NAILER
2X4 PER ENGINEERED
WOOD TRUSS
4" CONCRETE SLAB WITH #4
W.W.F. CENTERED
SEE FOOTER DETAIL 5/A1.2
FOR MORE INFORMATION
SEE FOOTER DETAIL 5/A1.2
FOR MORE INFORMATION
23'-4"
10'
SOFFIT
1X4 P.T. WOOD TRIM
STANDING SEAM METAL ROOF
8" CMU BLOCK W/ #5 VERT.
@ 32" O.C.; ALTERNATE SIDES
CHAIN FENCE
4" CONCRETE SLAB WITH #4
W.W.F. CENTERED
5
8
" GYPSUM WALL
BOARD; ORANGE
PEEL FINISH
8" CMU BLOCK W/ #5
VERT. @ 32" O.C.;
ALTERNATE SIDES
2X4
R-30
INSULATION
SEE FOOTER DETAIL 5/A1.2
FOR MORE INFORMATION
SEE FOOTER DETAIL 5/A1.2
FOR MORE INFORMATION
C
2020 LIVESTONE CONSULTING INC.
SEAL
SHEET NUMBER
REVISIONS
PROJECT NUMBER
SHEET TITLE
DESCRIPTIONNO. DATE
www.LivestoneConsulting.com
GILAD LIVINGSTONE
AR 94331
PROJECT
PARCEL #:
15-25-18-0000-00300-0000
NEW CONSTRUCTION
PASCO COUNTY
OWNER
L1302130000320
L1302130000317
SHERIFF DEPARTMENT
7220 Osteen Road
New Port Richey, FL 34653
2901 W. Busch Blvd., Ste. 204
Tampa, FL 33618
Phone: 813-345-2612
PASCO COUNTY
SHERIFF DEPARTMENT
DATE ISSUED:
REVIEWED BY: GBL
DRAWN BY: JEM & JLS
DESIGNED BY: JEM
04/14/2020
CANINE KENNEL
A5.1
BUILDING
SECTIONS
AND NOTES
1 BUILDING SECTION
1/4"=1'-0" NOTE:
2 BUILDING SECTION
1/4"-1'-0" NOTE:
TOILET
3'-6"
4'-0"
LAVATORY
SOAP
DISPENSER
ACCESSIBILITY
GRAB BAR
MIRROR
1'-6"
4'-0"
1'-3"
6'-1"
SHOWER PAN
SHOWER HEAD
6 X 6 TILE;
1
8
" GROUT LINE
4'-9"2'-0"
STORAGE SHELVES
ACCESSIBILITY
GRAB BAR
TOILET
3'-6"
4'-0"
LAVATORY
SOAP
DISPENSER
ACCESSIBILITY
GRAB BAR
MIRROR
1'-6"
4'-0"
1'-3"
6'-1"
SHOWER PAN
SHOWER HEAD
6 X 6 TILE;
1
8
" GROUT LINE
4'-9"2'-0"
STORAGE SHELVES
ACCESSIBILITY
GRAB BAR
B
A6.0
D
A6.0
C
A6.0
A
A6.0
HW
C
2020 LIVESTONE CONSULTING INC.
SEAL
SHEET NUMBER
REVISIONS
PROJECT NUMBER
SHEET TITLE
DESCRIPTIONNO. DATE
www.LivestoneConsulting.com
GILAD LIVINGSTONE
AR 94331
PROJECT
PARCEL #:
15-25-18-0000-00300-0000
NEW CONSTRUCTION
PASCO COUNTY
OWNER
L1302130000320
L1302130000317
SHERIFF DEPARTMENT
7220 Osteen Road
New Port Richey, FL 34653
2901 W. Busch Blvd., Ste. 204
Tampa, FL 33618
Phone: 813-345-2612
PASCO COUNTY
SHERIFF DEPARTMENT
DATE ISSUED:
REVIEWED BY: GBL
DRAWN BY: JEM & JLS
DESIGNED BY: JEM
04/14/2020
CANINE KENNEL
A6.0
INTERIOR
ELEVATIONS
AND NOTES
1 RESTROOM ELEVATION
1/2" = 1'-0" NOTE:
1 RESTROOM ELEVATION
1/2" = 1'-0" NOTE:
3 KEY PLAN
N/A NOTE:
A
UNISEX RESTROOM 105
B
UNISEX RESTROOM 105
C
UNISEX RESTROOM 106
D
UNISEX RESTROOM 106
HW
PLUMBING
BELOW
GRADE
PLUMBING IN
CEILING ATTIC
SPACE
WATER SUPPLY
FROM EXISTING
PUBLIC WATER LINE
HB
HB HB
HBHB
HBHB
HB
HB HB
C
2020 LIVESTONE CONSULTING INC.
SEAL
SHEET NUMBER
REVISIONS
PROJECT NUMBER
SHEET TITLE
DESCRIPTIONNO. DATE
www.LivestoneConsulting.com
GILAD LIVINGSTONE
AR 94331
PROJECT
PARCEL #:
15-25-18-0000-00300-0000
NEW CONSTRUCTION
PASCO COUNTY
OWNER
L1302130000320
L1302130000317
SHERIFF DEPARTMENT
7220 Osteen Road
New Port Richey, FL 34653
2901 W. Busch Blvd., Ste. 204
Tampa, FL 33618
Phone: 813-345-2612
PASCO COUNTY
SHERIFF DEPARTMENT
DATE ISSUED:
REVIEWED BY: GBL
DRAWN BY: JEM & JLS
DESIGNED BY: JEM
04/14/2020
CANINE KENNEL
A7.0
ARCHITECTURAL
PLUMBING PLAN
AND NOTES
1 PLUMBING PLAN
3/16" = 1'-0" NOTE:
LEGEND:
INDICATES DIRECTION OF FLOW
GENERAL NOTES:
1. GENERAL CONTRACTOR'S PLUMBER TO SIZE PIPES ACCORDINGLY; REFER TO MANUFACTURER'S
SPECIFICATIONS FOR FIXTURE LINE SIZES.
2. INSTALL ALL FIXTURES PER MANUFACTURER'S RECOMMENDATIONS.
3. ALL PLUMBING SHOWN ARE FOR REFERENCE ONLY; REFER TO ENGINEERED PLUMBING
DRAWINGS FOR MORE INFORMATION INCLUDING SIZES, DIAGRAMS, SANITATION PLAN, AND
CALCULATIONS.
4. ALL HOSE BIB CONNECTIONS LOCATED WITHIN THE CEILING ARE TO BE PULL DOWN SELF
RETRACTING STYLE; GENERAL CONTRACT TO PROVIDE
CLASSIFICATION OCCUPANCY WATER CLOSETS
MALE FEMALE
LAVATORIES BATHTUBS /
SHOWERS
DRINKING
FOUNTAIN
OTHER
MALE FEMALE
BUSINESS B 1 PER 25 FOR THE
FIRST 50 AND THEN 1
PER 50 FOR THE
REMAINDER
EXCEEDING 50
---- 1 PER 100 1 SERVICE SINK1 PER 40 FOR THE
FIRST 80 AND THEN 1
PER 80 FOR THE
REMAINDER
EXCEEDING 80
2 O 1 12
PER 2017 FBC. PLUMBING, 6TH EDITION TABLE 403.1 AND 410.2
TOILET EQUIPMENT SCHEDULE
CODE ITEM MANUFACTURER & PRODUCT #
NOTES
A GRAB BARS ASI 3701-18P (18"), -36P (36") & -42P (42")
B TOILET TISSUE DISPENSER KC PROFESSIONAL #09551
C COAT HOOK (ACCESSIBLE) BOBRICK #B-7671
D SOAP DISPENSER DERMA FOAM E - KAY CHEMICAL COMPANY
E HAND DRYER EXCEL DRYER INC XL-BW
F MIRROR ASI 0620-2436
1. OPERATING CONTROLS OF ALL HAND DRYERS, SOAP DISPENSERS AND MULTI PURPOSE UNITS TO BE 42" A.F.F.
2. G.C. TO FIELD VERIFY ALL SIZES.
3. PROVIDE BLOCKING FOR ALL WALL-MOUNTED FIXTURES AND ACCESSORIES.
4. TOILET TISSUE & PAPER TOWEL DISPENSERS SUPPLIED FREE FROM LOCAL DCP; INSTALLED BY G.C.
5. HAND DRYER TO BE ORDERED FROM NATIONAL ACCOUNT SUPPLIER, AND IS REQUIRED TO HAVE STANDARDS DBI GREEN
MESSAGING/BRANDING.
6. SEE ADA NOTES ON SHEET G1.3 FOR MORE INFORMATION.
TOTAL NEEDED
2 O 0 12TOTAL PROVIDED
NOTE:
1. RESTROOM PROVIDED ARE UNISEX RESTROOM COMPLYING WITH ALL APPLICABLE CODES.
2. DRINKING FOUNTAINS ARE PROVIDED AROUND THE SITE LOCATED AT EXISTING RESTROOM
FACILITIES.
PLUMBING LOAD CALCULATIONS
CLASSIFICATION OCCUPANCY WATER CLOSETS
MALE FEMALE
LAVATORIES BATHTUBS /
SHOWERS
DRINKING
FOUNTAIN
OTHER
MALE FEMALE
BUSINESS B 1 PER 25 FOR THE
FIRST 50 AND THEN 1
PER 50 FOR THE
REMAINDER
EXCEEDING 50
---- 1 PER 100 1 SERVICE SINK1 PER 40 FOR THE
FIRST 80 AND THEN 1
PER 80 FOR THE
REMAINDER
EXCEEDING 80
2 O 1 12
PER 2017 FBC. PLUMBING, 6TH EDITION TABLE 403.1 AND 410.2
TOTAL NEEDED
2 O 0 12TOTAL PROVIDED
NOTE:
1. RESTROOM PROVIDED ARE UNISEX RESTROOM COMPLYING WITH ALL APPLICABLE CODES.