In This Section…
Rigid and Intermediate Metal Conduit Fittings...................A-4–A-34
Conduit Dimensional Data ..............................................A-167–168
www.tnb.com
United StatesTel: 901.252.8000
800.816.7809Fax: 901.252.1354
Technical ServicesTel: 888.862.3289
Overview
Since the turn of the century, Thomas & Betts has been a recognizedleader in electrical fittings. Industry standards such as Chase® Nipples and Erickson® Couplings were introduced by Thomas & Betts and are still registered trademarks. This leadership continues. Here’s why...
The Complete Product Line
High-Performance Products
Quality and performance result when engineering design skills are combinedwith the manufacturing technologies required to produce them. The Thomas & Betts Fittings in this section are produced from many materials and by many manufacturing methods, each carefully selected for its end usesuitability. This combination gives you the reliable performance you expectfrom Thomas & Betts Raceway Fittings.
Innovative Designs
The real test of product design of electrical fittings lies in two areas: Job-suited installation and life of the job reliability. Thomas & Betts Fittingsprovide both because we listen. We listen to problems and suggestions from the field. Most of the products in this section result from the goodsuggestions of knowledgeable electrical people. Many were customer specials to solve particular installation and performance problems. You can benefit from their experience.
Lower Installed Cost
It is a function of purchase cost, availability, installation advantage and performance. Lower installed cost comes in every carton of Thomas & Betts Raceway Fittings.
Approvals and Listings
Electrical raceways require accessory fittings that provide the mechanicalstrength, ground continuity and environmental integrity of the system. As newraceways have been introduced, Thomas & Betts engineers have designedfittings that meet the requirements of the National Electrical Code® as well as the listing requirements of the Underwriter’s Laboratories and the CanadianStandards Association. You can use Thomas & Betts Fittings with confidence.
A-2
United StatesTel: 901.252.8000
800.816.7809Fax: 901.252.1354
Technical ServicesTel: 888.862.3289
www.tnb.com
NOTE: In the United States, boxes and fittings are not listed or marked for use in Class IDivision 2 locations. See NEC® 501.10B for the wiring methods allowed in these areas.
DURA-PLATE® Corrosion-Resistant Fittings have a T&B plating processthat provides excellent corrosion resistance on threaded steel andmalleable iron fittings for use in harsh environments.
DURA-PLATE® Corrosion-Resistant Fittings utilize an electro-platingprocess that ensures a uniform thickness of protective material overthe entire part. Conventional hot dip coatings deposit an uncontrolledbuildup of material on the part, especially in threaded areas. Thisexcess buildup must be removed to enable mating parts to function.
The process of removing this buildup in the threads in turn damagesthe coating and compromises the effectiveness of the protection.
An additional drawback of hot dip coating is that the lower ductility of the alloyed interface layer that is formed during the hot dip process can cause spalling if the item is deformed after coating.
In addition to the uniformity of the coating, the distinctive gold color of the plating enables immediate recognition that the part has beenprepared for exposure to harsh environments and confirms the extraprotection by visual inspection.
DURA-PLATE® Corrosion-Resistant Fittings have been subjected to salt spray tests conducted according to ASTM Specification B-117.The results of Corrosion-Resistant Fittings tests, along with galvanizedparts, appears below:
Overview
DURA-PLATE® Finish — Corrosion-Resistant Finish ProtectsFittings in Harsh Environments
Ordering Information• Add the prefix “040-” to the standard catalog number —
for example: a 5332 with DURA-PLATE® Corrosion-ResistantFittings protection would be ordered as “040-5332”.
• Check for catalog numbers in stock
• Allow 6–8 weeks for delivery on nonstock items
• Add 30% to price of standard item
• Minimum order is standard package quantity
®
A-3
United StatesTel: 901.252.8000
800.816.7809Fax: 901.252.1354
Technical ServicesTel: 888.862.3289
www.tnb.com
Rigid and Intermediate Metal Conduit Fittings
Locknuts
Application• To connect externally threaded conduit or connector
to a threadless opening in a box or enclosure
• To effectively bond conduit or connector to box or enclosure
(i) Provide extended reach for clamping on thin boxes and enclosures
(ii) Cut through protective coating on box and enclosure, thereby ensuring ground continuity
(iii) Permit tightening from outside
(iv) Prevent loosening under vibration
• 106 Series provided with a hardened cone point screw
Standard Material140 Series & 106 Series3⁄8" thru 2" steel (hardened) 21⁄2" thru 6" Malleable IronAll screws steel
141AL Series
All copper-free aluminum
Standard Finish
All steel and malleable iron locknuts, including electro zinc-plated bonding screws and chromate coated all-aluminum locknut, degreased
Range3⁄8" through 6" conduit (All threads straight pipe [NPS]) (140 Series) 1⁄2" through 4" conduit (106 Series & 141AL Series)
Listings/Compliances
UL (UL File No. E-23018)CSA [catalog numbers 108, 109, 110 and 111. All 140 Series
except catalog number 140.] (LR-2884, LR-4484)UL 514BCSA C22.2 No. 18NEMA FB1NFPA 70Federal Specification replaced by A-A-50553Federal Standard H-28 (Threads)
Case Hardened LocknutsCase hardened locknuts make fittings faster and easier to install. Casehardened locknuts do not slip or turn, thereby protecting the biting edge.Case hardened locknuts bite through paint into the enclosure, providingexcellent continuity of ground (typical T&B/Thomas & Betts fitting with casehardened locknuts successfully passed minimum fault current of 10,000amps RMS). Case hardened locknuts, when assembled in the intendedmanner, will not vibrate loose, thereby ensuring excellent ground continuity.
140 Series141AL Series
106 Series
A-4
United StatesTel: 901.252.8000
800.816.7809Fax: 901.252.1354
Technical ServicesTel: 888.862.3289
www.tnb.com
Rigid and Intermediate Metal Conduit Fittings
Available in your choice of steel/malleableiron, aluminum or stainless steel.
Ensures positive bonding of conduit to boxand prevents loosening due to vibration!
Bonding Locknuts
• Steel or malleable iron (steel through 2")
• Can be used anywhere an ordinary locknut is installed
• Also can be used for Service Entrance applications in conformance with code
• T&B rigid conduit and EMT (thinwall) fittings comply with Federal Specification A-A-50553
Application• For quick installation of bonding jumper
to multiple metal conduits (Rigid and IMC)
• Designed to bush conductors and prevent insulation damage
Features• Ease of installation, lay in lug design
• Cast malleable iron body designed to lock insulator in place within body, reducing common assembly problem resulting in dislodging of insulator
• Insulator rated for 150° C/302° F application
• Look for the unique T&B blue color, ensuring the highest quality fitting
Standard Material/FinishBody: Electro zinc plated
Lay-In Lug: Aluminum/tin plated
Insulator: Thermoplastic 150° C/302° FApplication with 94V-0 flammability
Wire Clamping Screw
Insulator
Set Screw (1)
3870 Series
Lay-In Lug
BushingCasting
Threaded Insulated Grounding Bushing
Rigid and Intermediate Metal Conduit Fittings
A-8
United StatesTel: 901.252.8000
800.816.7809Fax: 901.252.1354
Technical ServicesTel: 888.862.3289
www.tnb.com
Blackjack® — Grounding Bushing
The Blackjack® Grounding Bushing never has to be threaded onto a conduit. It is simply placedin position on either a threaded or non-threadedrigid or IMC conduit, with the grounding lug inperfect position to accept the grounding wire —even in tight installations.
It’s as simple as one, two, three!
Compare the installation with conventionalbushings that must be threaded onto theconduit. In tight areas, you may have to remove
the grounding lug, keep up with the loose partsand then reattach the lug. Then you still have to twist and turn the bushing to get the lug in position to accept the grounding wire.
The Blackjack bushing does away with theseneedless delays for good, making it the idealgrounding bushing — and the only logicalchoice for small spaces, corners and multipleconduit runs. And, because the grounding lug is an integral part of the bushing, it's designednot to fall off or get lost.
Lug Screw:
14-4: Slotted
14-2/0: Slotted
6-4/0: Internal Hex Drive
Standard Material/FinishBody: Malleable Iron or Aluminum
RangeConduit: 1⁄2" thru 6" threaded or threadlessrigid/IMC
Wire Range: #14 AWG to 4/0 AWG CU/AL
Listings/CompliancesUL File #E3060
CSA File #LR2884
UL 514B & U.L. 467
CSA C22.2 No. 18 & CSA C22.2 No. 41
Mounting screwwith nylon lockingpatch has a conepoint to lockbushing securely in place.
Insulator surface features a roundeddesign to reducedrag and preventabrasion duringwire pulling.
Cast “threads”opposite themountingscrew tightenthe fit duringinstallation.
Angle of lug screwimproves accessibility
when securinggrounding wire.
Integral groundinglug enhancesground continuity.Added groundwire range takingreduces inventory.Accepts copper or aluminum groundwires.
Insulating nylon surface is 150° Crated and coverstop of bushing,including lug corners.
The Blackjack® bushing providessuperior ground continuity.The design of the Blackjack bushing has an integral, cast-on grounding lug for betterground continuity. This means that the Blackjack bushing stands up to intense loads.
Secure grip forms lasting bond.The Blackjack bushing’scone-point mounting screwbites securely into boththreaded and non-threaded rigid conduits. And theBlackjack bushing’s nylonlocking patch is designed to prevent the screw fromloosening due to vibration.
Reduce inventory.Because the Blackjack Grounding Bushing is designed for threaded and non-threadedconduits, and the ground lugs are designed tohandle an extended range, the number of partsin inventory is reduced by up to two-thirdswithout losing any application coverage.
Blackjack® — Conduit Grounding Bushing
Innovative design makes installation quicker, easier.
Suggested Specifications: Insulated grounding and bonding bushing (Series BG050-BG600)
Where code requires bonding and grounding of single or multiple metal conduits, or positive bonding and grounding of metal conduit to the box, enclosure or auxiliary gutter, the end of the conduit shall be equipped with an insulated metallic grounding and bonding bushing series BG050-14-20 as manufactured by Thomas & Betts.
Grounding and bonding bushings used shall be approved for the purpose and (i) Shall be of malleable iron/steel/aluminum construction adequately protected
against corrosion.
(ii) Bushing insulator shall be listed or certified for 150° C/302° F application with a flammability rating of 94V-O. Insulator must be positively locked in place.
C
D
EØA
A-9
United StatesTel: 901.252.8000
800.816.7809Fax: 901.252.1354
Technical ServicesTel: 888.862.3289
www.tnb.com
Rigid and Intermediate Metal Conduit Fittings
Meets and surpasses NEC® requirements!Insulated Throat Fittings
Locknut-type base improves bonding and resists loosening under vibration.
• Aluminum, steel or malleable iron (steel through 11⁄2")
• Smoothly rounded shoulder covers end of conduit
• Broad flange covers knockout hole
• High ribs for easy tightening with fingersor with wrench
• 1⁄2" to 11⁄2" sizes, formed in steel, feature extra-smooth shoulders
Metallic Bushings
Perfect threads for easy thread-on!
• Impact-resistant plastic insulation
• Ribbed for easy, secure gripping
• UL Listed 105° C
Plastic Insulating Bushings
All Plastic InsulatingBushings
CAT. NO. DIMENSIONS (IN.)STL. OR M.I. ALUM. SIZE A B
Application• When assembled to the end of a threadless conduit,
provides a well-rounded insulating surface over whichconductors may be pulled or on which conductors maybear while in service
Features• Designed to be popped onto, and bush, conduit end
• Fast, easy installation without screws
• High-impact thermoplastic construction
C
B
A
1. Cut conduit end squarely.Remove sharp edges and burrson inside and outside diametersby reaming or filing.
2. Slip the pop-on bushing overthe end of the conduit.
3. Using the flat surface of any standard utility tool such as anelectrician’s pliers (or a hammer with a block of wood for the largersizes), strike the bushing on its top surface using a series of lightblows until the end of the conduit rests against the bushing throat and conduit stop.
Standard MaterialHigh-impact thermoplastic listedfor 105° C (221° F) application
Flammability Classification 94 V-1
Standard FinishAs molded
Range1⁄2" through 4" conduit
Listings/CompliancesUL (UL File No. E-13938)
CSA (LR-2884, LR-4484)
UL 514B
NFPA 70
TRIB-150
TRIB-100
TRIB-75
For threadless rigid conduit and intermediate metal conduit.Insulating Bushing
Knockout PlugsApplication• To plug unused knockout openings in a box or enclosure
Features• One-piece construction designed to snap in place
• High impact strength self-extinguishing non-dripping (per UL-94) thermoplastic construction
1451 Series
Standard MaterialThermoplastic rated for 105° C (221° F) application
Standard FinishAs molded
Range.875" through 2.469" Nominal Diameter
Knockout opening (1⁄2" through 2" trade size knockouts)
Wall thickness of box or enclosure
.095" max. up to 1" trade size
.140" max. through 2" trade size.
Listings/CompliancesUL (UL File No. E13938)
CSA (LR589)
UL 514B
NFPA 70
A-13
United StatesTel: 901.252.8000
800.816.7809Fax: 901.252.1354
Technical ServicesTel: 888.862.3289
www.tnb.com
Rigid and Intermediate Metal Conduit Fittings
CAT. NO. DIMENSIONS (IN.)STL. OR M.I. ALUM. SIZE A B
841TB — 3⁄8" 15⁄167⁄16
842TB 842ALTB† 1⁄2" 19⁄1643⁄64
843TB 843ALTB 3⁄4" 13⁄8 19⁄32
844 844AL† 1" 111⁄163⁄64
845 845AL† 11⁄4" 21⁄3225⁄32
846 846AL 11⁄2" 23⁄8 13⁄16
847 847AL 2" 215⁄1631⁄32
848 848AL 21⁄2" 39⁄16 11⁄16
849 849AL 3" 43⁄8 11⁄4850 850AL 31⁄2" 51⁄8 15⁄16
851 851AL 4" 51⁄8 15⁄16
853 — 5" 61⁄2 15⁄16
854 — 6" 75⁄8 13⁄8
† Not UL Listed
Available with DURA-PLATE® Finish.
UL File No. E-23018
CSA File No. 2884
DIMENSIONS (IN.)CAT. NO. SIZE A B C
1942 1⁄2" 19⁄647⁄16
19⁄32
1943 3⁄4" 13⁄8 17⁄3223⁄32
1944 1" 111⁄1621⁄32
7⁄81945 11⁄4" 21⁄32
25⁄32 11⁄32
1946 11⁄2" 23⁄8 13⁄16 13⁄32
1947 2" 215⁄1631⁄32 111⁄32
1948 21⁄2" 39⁄16 11⁄16 17⁄16
1949 3" 43⁄8 1i 119⁄32
1950 31⁄2" 51⁄8 15⁄16 125⁄32
1951 4" 51⁄8 15⁄16 113⁄16
1953 5" 63⁄8 15⁄16 113⁄16
1954 6" 75⁄8 13⁄8 17⁄8
UL File No. E-23018
CSA File No. 2884
CHASE® Nipples
CHASE® Nipples — Nylon-Insulated
Bush holes in metal boxes or enclosures!
Nylon insulator offers extra protection!
• 3⁄8" and 1⁄2" sizes in steel
• 3⁄4" to 6" sizes in malleable iron
• 1⁄2" to 4" sizes in copper-free aluminum
• 3⁄8" and 1⁄2" sizes in steel
• 3⁄4" to 6" sizes in malleable iron
• 1⁄2" to 6" sizes in copper-free aluminum
• Look for the unique T&B blue color ensuringthe highest quality fitting available
A-14
United StatesTel: 901.252.8000
800.816.7809Fax: 901.252.1354
Technical ServicesTel: 888.862.3289
www.tnb.com
Rigid and Intermediate Metal Conduit Fittings
For Threaded Rigid Metal Conduit/IMC/PVC Coated Rigid Metal Conduit.
Application• To connect threaded metal conduit (ferrous rigid/non-ferrous rigid/
PVC coated/or intermediate metal) to a threadless opening in a box or enclosure in outdoors or indoor location exposed to continuous or intermittent moisture
• To positively bond conduit to box or enclosure
Features• Rugged steel/malleable iron/copper-free aluminum construction
• Tapered internal threads for water-tight/dust-tight union (A)
• Threads relieved to prevent bottoming of conduit, ensuring sound assembly (B)
• Recessed sealing ring at box end; sealing ring captivated (C)
• Hardened steel/malleable iron/copper-free aluminum locknutsdesigned to provide high-quality ground continuity; extended reach of locknut permits clamping on thin boxes and enclosures (D)
• Insulated throat, insulates conductors, prevents abrasion and thinning of conductor insulation, reduces wire pull effort (E)
• Suitable for hazardous location use per following:
(i) Class I Division 2, Class II Division 1 & 2, Class III Division 1 & 2 per NEC 501-4 (b); 502-4 (a) and 503-3 (a)
(ii) Class II Groups E, F, G, & Class III locations per CEC 18-202; 18-252; 18-302; 18-352
National Electrical Code® states that, “Where practical, dissimilar metals incontact anywhere in the system shall be avoided to eliminate the possibilityof galvanic action.” The only exceptions, aluminum fittings and enclosures,are permitted to be used with steel conduit.
Joint Industrial Council (JIC) Electrical Standards also forbid dissimilarmetals in contact for the same reason and require that the fittings formetal conduit be of malleable iron or ductile iron and have impact strengthcomparable to that of the conduit.
Threaded Hubs (Bullet® Hubs)
(B)
(C)
(E)
PredeterminedCompression
370 Series370AL Series
Copper-Free AluminumCopper free aluminum castings for fittings have a maximum of 0.4%copper. The most detrimental effect of higher percentage of copper onaluminum base alloy is its decrease in corrosion resistance.
* Suitable for hazardous locations use in Class I, Div. 2; Class II, Div. 2; Class III, Div. 1 and 2where general purpose equipment is specifically permitted per NEC Section 500-2(a).
** Aluminum not available with insulated throat.
† UL Listed rain tight and CSA Certified watertight and dust tight
Available with DURA-PLATE® finish.
UL File No. E-23018
For Stl.: CSA File No. 2284
For AL.: CSA File No. 0637
Spacing Chart for Bullet® Hubs
MIN. SPACE FROMCENTER-TO-CENTER SPACING CENTER OF KO
Material – Hub and Locknut: zinc or copper-free aluminum
Insulating Throat: thermoplastic temp. rating – 105° C
Flammability Rating – 94V-0
Sealing Ring: Nitrile (BUNA “N”)
For Aluminum Hubs add suffix A (i.e., H050A). For Chrome-Plated Hubs add suffix CP (i.e., H050CP). For 316 Stainless Steel Hubs add suffix GRSST (i.e., H050GRSST). (1⁄2" through 2" only.) Meets NEMA sealing requirements for NEMA 3R, 4 & 13 enclosures.
UL Listed and CSA Certified. CSA Certified for hazardous locations Class II Groups E, F, G, Class III (NEC 501.10B).
UL File No. E-23018 CSA File No. 4484
Chrome-Plated Hubs (suffix-“CP”) are rated NEMA 4X.
Throat Dia. E
D
Never before has a single hub fit like this one. Designed for unequalled performance. The innovative engineering of the T&B® Hub will, quite simply, raise your performanceexpectations for threaded hubs. Look for the distinctive blue color to ensure the quality of a Thomas & Betts fitting.
Sealing Ring and Groove with innovative profile outperformsstandard O-ring design. Sealing ring is captivated in placebefore installation and resists buckling or slipping duringinstallation. The seal groove is designed for optimumcompression of the sealing ring. The sealing ring isdesigned to provide a complete 360° seal, even when the conduit is not perpendicular with the enclosure. (See Figure 1)
Locknut Design with peripheral slots and a hexagonal/angled spline spaced every 30° enables easy application of torque with wrench or hammer and screwdriver.(See Figures 2 & 3)
Sharper and Deeper Teeth on locknut and body designedfor a more penetrating bite for improved bonding to theenclosure.
Hexagonal/Splined Body Design for fast, easy installationwith wrench or hammer and screwdriver.
Precision Machined Tapered Threads designed to createwatertight union.
Insulated Throat molded from 105° C rated thermoplasticwith a flammability rating of 94 V-O.
L050GR-TB 1⁄2 11⁄2 13⁄32 #10-32 x 1⁄4" #10L075GR-TB 3⁄4 111⁄16
13⁄32 #10-32 x 1⁄4" #10L100GR-TB 1 2 13⁄32 #10-32 x 1⁄4" #10L125GR-TB 11⁄4 23⁄8 15⁄32
1⁄4-20 x 1⁄4" #10L150GR-TB 11⁄2 23⁄4 15⁄32
1⁄4-20 x 5⁄16" #8L200GR-TB 2 31⁄4 15⁄32
1⁄4-20 x 5⁄16" #8L250GR-TB 21⁄2 33⁄4 11⁄16
1⁄4-20 x 5⁄16" #6L300GR-TB 3 43⁄8 23⁄32
1⁄4-20 x 5⁄16" #6L350GR-TB 31⁄2 5 23⁄32
1⁄4-20 x 5⁄16" #6L400GR-TB 4 51⁄2 23⁄32
1⁄4-20 x 5⁄16" #4L500GR-TB 5 65⁄8 23⁄32
3⁄8-16 x 3⁄8" #2L600GR-TB 6 711⁄16
23⁄323⁄8-16 x 3⁄8" #1
Material – Locknut: zinc or copper-free aluminum UL File No. E-3060
For Aluminum Locknuts add suffix A. (i.e., L050GRA) CSA File No. 4484
For Chrome-Plated Locknuts add suffix CP. (i.e., L050CP). For 316 Stainless Steel Locknutsadd suffix SST (1⁄2" through 2" only.) For Locknut with Lay In Lug add suffix GRL
XD Expansion/Deflection CouplingUse the T&B XD Expansion/Deflection Coupling to join two conduit runsin applications where movement in any direction is required. The couplingprovides a flexible, watertight connection, accommodating axial or parallelmovement of up to 3⁄4" and angular movement of up to 30° from normal.
• Ideal for use in bridges, tunnels, interbuilding walkways,docks and piers, wastewater and water treatment facilitiesand other applications in which conduit runs are subject tomovement due to external forces or temperature changes
• Suitable for use indoors, outdoors, direct buried or embedded in concrete
• Watertight, flexible neoprene outer jacket, zinc-plated andacrylic-painted hubs and stainless steel tamperproof strapsensure superior corrosion resistance — ideal for use inharsh environments
• Copper ground mounting plates and grounding bondingjumper both entirely enclosed to safeguard against theft
• Includes an Erickson® type conduit union for faster, easierinstallation to reduce labor costs
• Durable stainless steel inner sleeve provides a constant,smooth inner diameter in any position to ease wire pullingand protect wire insulation from damage
• NPT threaded hubs fit standard threaded rigid metal conduit
• Can also be used with rigid PVC conduit with the useof standard adapters (not supplied)
Please consult Technical Services for special orders and availability of products not shown in this list.
Suggested Specifications for Expansion Fittings for Rigid Steel or Intermediate Metal Conduit
Where raceways require expansion fittings to compensate for thermalexpansion and contraction and where expansion fittings and telescopingsections of metal raceway shall be made electrically continuous by bondingjumpers or other means:
• The fitting will be constructed from malleable or ductile iron withexterior and interior zinc plating for corrosion protection.
• The fitting shall be constructed so that disassembly is not requiredduring installation.
• The fitting shall be raintight after installation.
• The fitting shall have an internal bonding jumper constructed of atinned copper braid, sized to meet UL fault current test requirementsand comply with bonding requirements — NEC Article 250.98
• External bonding jumper shall not be required to comply with NECrequirements.
• Accepted Manufacturers: Thomas & Betts - XJG-TB Series
C
B
A
XJG-TB Conduit Expansion Coupling for Rigid and Intermediate Metal Conduit
A-24
United StatesTel: 901.252.8000
800.816.7809Fax: 901.252.1354
Technical ServicesTel: 888.862.3289
www.tnb.com
8" Movement
Slide the fitting onto the conduit until it stops at the internal sliding bushing. Tighten and you’re ready. No parts to reassemble!
With a wrench, tighten the gland nut to compress the Teflon packing, creating a raintightseal around the conduit.
33
11
22
Internal SlidingBushing (keyed)
Internal BondingJumper
BondingBushing
GlandNut
No disassembly required!XJG Conduit Expansion Coupling
Thread the next length of conduit into the other end of the fitting and tighten. You’re done!
Rigid and Intermediate Metal Conduit Fittings
Features• Fast and easy installation — no disassembly required
• No external grounding strap needed — internal bondingjumper is protected from tampering and the environment
• Exceeds code requirements for long conduit runs to permitlinear movement
UL File E23018, Std. 514B, Suitable for Wet Locations
CSA File LR2884, Std. C22.2 No. 18
NEC 250.98
XJG24-EMT
B
A
A-25
United StatesTel: 901.252.8000
800.816.7809Fax: 901.252.1354
Technical ServicesTel: 888.862.3289
www.tnb.com
8123 Series
8120 Series
8130 Series
Threadless Connector/Coupling(For Threadless Rigid Metal Conduit and Intermediate Metal Conduit)
Application• To connect and effectively bond threadless
rigid metal conduit/intermediate metal conduitto a box or enclosure, or to couple ends ofthreadless conduit
Features• Steel/Malleable Iron construction
• Case-hardened ring bites into conduit for high-quality continuity and grip
• Nylon insulator firmly secured in placeprotects conductors and reduces wire pullingeffort by as much as 50%; prevents threaddamage in handling
• Case-hardened steel locknut or malleable ironlocknut designed to provide a positive bond
• Suitable for concrete-tight application
• Capable of carrying ground fault currents upto 10,000 amps RMS (1⁄2" through 11⁄2" size)and 20,000 amps RMS (2" and above sizes)for a duration of current 3 cycles
Standard MaterialNut, Gland . . . . . . 1⁄2" to 1" Steel – 11⁄4" to 4" Malleable Iron
8975 4" 43⁄16 11⁄8Sizes 1⁄2"–2" made of steel. Sizes 21⁄2"–4" are malleable iron.Available with DURA-PLATE® Finish. UL File No. E-23018 CSA File No. 2884
Eliminates the need for conduit threading!
Insulated Set-Screw Connector
No need to thread conduit ends when joining rigid conduit!
Set-Screw CouplingCAT. CONDUIT DIMENSION (IN.)NO. SIZE A
bond threaded ends of rigid metalconduit/intermediate metal conduitwhere neither length of conduit can be rotated
Features• Malleable Iron/Steel/Copper-free
Aluminum construction
• Free fitting threads ensure easy assembly
• Permits conduit coupling without rotating either conduit
• Provides rigid in-line coupling with high- quality grounding; will not loosen under vibration
• Suitable for concrete-tight application
• Capable of carrying ground faultcurrents up to 10,000 amps RMS (1⁄2" through 11⁄2" size) and up to 20,000amps RMS (2" and above) (duration offault current 3 cycles) (674 series tested)
With an ERICKSON® coupling, a conduit runmay be completed when neither conduit canbe turned. A conduit run may also be brokenwithout taking down the whole run. Conduitjoined with ERICKSON® Couplings is rigid andin line and vibration will not loosen theconnections. Malleable iron.
T&B’s Split Couplingis a simple method tojoin threaded conduitsin retrofits or in snugareas. Available in 1⁄2" to 6".
Rigid and Intermediate Metal Conduit Fittings
CAT. DIMENSIONS (IN.)NO. SIZE A B C
1250-TB 3⁄4" to 1⁄2" 11⁄8 5⁄8 3⁄16
1261 1" to 1⁄2" 17⁄1621⁄32
3⁄16
1251 1" to 3⁄4" 13⁄8 11⁄163⁄16
1262 11⁄4" to 1⁄2" 113⁄1623⁄32
3⁄16
1263 11⁄4" to 3⁄4" 113⁄1623⁄32
3⁄16
1252 11⁄4" to 1" 13⁄4 25⁄327⁄32
1253 11⁄2" to 11⁄4" 2 13⁄161⁄4
1254 2" to 11⁄2" 23⁄8 13⁄169⁄32
1255 21⁄2" to 2" 3 11⁄4 3⁄81256 3" to 21⁄2" 35⁄8 11⁄2 1⁄21257 31⁄2" to 3" 41⁄8 19⁄16
1⁄21258 4" to 31⁄2" 45⁄8 19⁄16
1⁄2
* All items shown in this chart are suitable for use in hazardous locations where general purpose equipment is specificallypermitted by the NEC; Class I, Div. 2; Class II, Div. 1 & 2; Class III, Div. 1 & 2, NEC 501-4(b); 502-4(a) (b); 503-3(a) (b).
Available with DURA-PLATE® Finish. UL File No. E-23018 CSA File No. 2884
CAT. DIMENSIONS (IN.)NO. SIZE A B C
1245 1⁄2" to 3⁄4" 113⁄32 11⁄161⁄2
1246 3⁄4" to 1" 111⁄16 11⁄4 15⁄32
1244 1" to 11⁄4" 21⁄16 111⁄321⁄2
1247 11⁄4" to 11⁄2" 25⁄16 13⁄8 9⁄16
* All items shown in this chart are suitable for use in hazardous locations where general purposeequipment is specifically permitted by the NEC; Class I, Div. 2; Class II, Div. 1 & 2; Class III,Div. 1 & 2, NEC 501-4(b); 502-4(a)(b); 503-3(a)(b).Available with DURA-PLATE® Finish.UL File No. E-23018CSA File No. 2884
The ideal solution for applications requiring longer thread length!
Panel Connector Extensions
• Will combine with any fittingwith a male thread
• Male thread of panel connectorextension is 1" long
• Malleable iron construction
Adapt an outlet hole to the next larger size of conduit!
Male Enlargers*
• Built-in bushing covers rough ends of conduit
• Malleable iron construction
Adapt any outlet to the next smaller size of conduit!
Female Reducers*• Hex shoulder for easy wrench tightening
Thomas & Betts offers stainless steel pipe strapsto support and securely fasten rigid, IMC andEMT conduit. One- and two-hole stainless steelstraps are ideal for industrial applications suchas petro-chemical plants, manufacturing plants,pulp and paper mills, food processing, powerplants, refineries and mining operations.Stainless steel pipe straps are also useful incommercial applications in schools, hospitals,office buildings, airports, casinos and stadiums.
Stainless Steel Pipe Straps• Higher degree of corrosion resistance than traditional zinc-plated
or hot-dipped galvanized straps
• One and two-hole straps for EMT sizes 1⁄2" through 2"
• One and two-hole straps for Rigid and IMC size 1⁄2" through 4"
• 303 stainless steel
DIMENSIONS (IN.)CAT. NO. SIZE A B
3700 3⁄4" to 3⁄8" 13⁄8 45⁄64
3701 3⁄4" to 1⁄2" 13⁄8 7⁄83702 1" to 3⁄8" 15⁄8 45⁄64
3703 1" to 1⁄2" 15⁄8 7⁄83704 1" to 3⁄4" 15⁄8 13⁄32
3705-TB 11⁄4" to 3⁄8" 2 45⁄64
3706 11⁄4" to 1⁄2" 2 7⁄83707 11⁄4" to 3⁄4" 2 13⁄32
3708 11⁄4" to 1" 2 123⁄64
3709 11⁄2" to 3⁄8" 21⁄4 45⁄64
3710 11⁄2" to 1⁄2" 21⁄4 7⁄83711 11⁄2" to 3⁄4" 21⁄4 13⁄32
3712 11⁄2" to 1" 21⁄4 123⁄64
3713 11⁄2" to 11⁄4" 21⁄4 123⁄32
3714 2" to 1⁄2" 23⁄4 7⁄83715-TB 2" to 3⁄4" 23⁄4 13⁄32
Conforms to NEC SECT. 300-5-c. UL not applicable. CSA File Nos. 2884 and 4484.
A
B
1351–13541350
Conduit Spacers(For Rigid Metal Conduit, Intermediate MetalConduit and Electrical Metallic Tubing)
Rigid and Intermediate Metal Conduit Fittings
CAT. NO. SIZE
690TB 1⁄2"691TB 3⁄4"692TB 1"693TB 11⁄4"
CSA File No. 2884
• Includes bolts
• Steel construction
DIMENSIONS (IN.)CAT. NO. SIZE A B
440 1⁄2" 15⁄8 127⁄32
441 3⁄4" 13⁄4 21⁄8442 1" 2 217⁄32
UL File No. E-23018
CSA File No. 2884
CONDUIT DIMENSIONS (IN.)CAT. NO. SIZE A C
1490 1⁄2" 3 119⁄32
1491 3⁄4" 39⁄16 17⁄81492 1" 41⁄4 223⁄64
1493 11⁄4" 531⁄64 213⁄16
1494 11⁄2" 61⁄4 27⁄81495 2" 63⁄4 39⁄16
UL File No. E-23018. CSA File Nos. 2884 and 589
One-piece fitting couples armored cable or flexible conduit to threaded rigid conduit!
TITE-BITE® Combination Couplings — Armored Cable for Threaded Rigid
• Tite-Bite® wedge holds conduit securely with a double grip
• When used with a Chase® nipple, this fitting will connect flexible conduit to outlet boxes,enabling more wiring space in the box than the usual connector
• UL Listed as a grounding means under NEC 350-5
• Malleable iron construction
Mount flat against wall, eliminating the need to offset conduit!
Entrance Ells
Adjustable design fits a wide range of flange sizes!
Adjustable Beam Clamps CAT. NO. DESCRIPTION
700TB Fits Flange 23⁄4"–73⁄8"701 Fits Flange 7"–12"703 Special Bolt and 3 Nuts
CSA File No. 2884.
Fits any flange, tapered or straight, up to 5⁄8" thick!
Conduit Supports
• Designed for a straight pull in either direction
• Carefully bushed
• Make it easy to pull heavy wires without damage to insulation
• Made of copper-free aluminum
• For use with standard rigid conduit, EMT or IMC
• Broad hook holds conduit at any desired angle
• Malleable iron construction
A-34
United StatesTel: 901.252.8000
800.816.7809Fax: 901.252.1354
Technical ServicesTel: 888.862.3289
www.tnb.com
Conduit Outlet Bodies
A-35
United StatesTel: 901.252.8000
800.816.7809Fax: 901.252.1354
Technical ServicesTel: 888.862.3289
www.tnb.com
T&B Conduit Fittings for Ordinary and Hazardous LocationsThomas & Betts offers a broad range of conduit bodies, conduit boxes,conduit fittings, unions, sealing fittings, drains and cable fittings for bothordinary and hazardous locations. Complete information on applications,features, materials, finishes, size range and certifications is provided in the following pages.
Conduit Bodies (for ordinary locations)
For raceway systems to provide pull outlets, 90° bends, splices, taps,mounting outlets, etc.
Cast Device Boxes (for ordinary locations)
For raceway systems to accommodate wiring devices, serve as pull boxes,and provide entrances for taps and splices.
Round cast outlet boxes used with rigid conduit to serve as pull andsplice boxes, easy access to wiring, act as a housing for instruments,apparatus, etc.
GUA Conduit Outlet Bodies
Reducers, Plugs, Unions (for ordinary and hazardous locations)
Includes reducers for connecting conduit of dissimilar dimensions,plugs for unused conduit openings and hubs, and unions for threadedconduit systems.
RE, PLG REC Reducers, Plugs and Adapters, UNY/UNF Unions
Sealing Fittings and Drains (for ordinary and hazardous locations)
Cast fittings used with rigid conduit to seal sections from passage of vapors,flame or gases or explosions. Drains provide ventilation as a breather andas a drain in moist locations.
EYS/EYD Sealing Fittings & ECD Drains
Cable Fittings (for ordinary and hazardous locations)
For armored, metal clad, jacketed or unjacketed and unarmored cablesthrough a bulkhead or enclosure in ordinary or hazardous areas.
FORM 7 For neat, compact installation of rigidthreaded conduit.
FORM 8 For heavier conductors using rigidthreaded conduit.
Series 35 For economy installations of rigid threaded conduit.
Red•Dot® AluminumDie-Cast
For rigid threaded conduit installation — copper-free aluminum.
Red•Dot® Thinwall (EMT)
For set-screw installation using thinwallconduit (EMT) — copper-free aluminum.
Mogul Conduit Fittings For larger conduits, spacious, accessiblewiring chambers.
Conduit Outlet Bodies
ApplicationConduit Bodies are installed in conduit systems to:
• Connect conduit sections
• Act as pull outlets when conductors are being installed
• Provide easy access for splices in branch conductors
• Make 90˚ bends in conduit runs
• Act as mounting outlets for wiring devices and lighting fixtures
• Provide access to conductors for maintenance and future system changes
Features• Standard features include tapered (NPT) threads
and integral bushings to protect wire insulation
• T&B Form 7 bodies and covers are interchangeable with other manufacturer’s Form 7 bodies and covers
• T&B Form 8 bodies and covers are interchangeable with other manufacturer’s Form 8 bodies and covers
• T&B Form 7 and Form 8 bodies feature BlueKote internal coating for easier wire pulling
• T&B Series 35 bodies and covers are interchangeablewith other manufacturers’ 35/5 Series iron and steelbodies and covers
MaterialsForm 7, Form 8 and Series 35 Conduit Bodies . . . . . . . . Sand-cast class 30
*Aluminum conduit bodies (A and B series) furnished with one stamped steel cover ** 1⁄2" through 11⁄4" have (2) mounting holes; 11⁄2" through 4" have (4) mounting holes
Conduit Outlet Bodies
Replacement Covers and GasketsSHAPE HUB SIZE (IN.)
For aluminum conduit bodies pre-assembled with covers and gaskets, request Red•Dot® D-PAK® Series Conduit Bodies for rigid and IMC conduit.
Form 7 Body, Gasket and Cover — One Number! NEW!NEW!
Now you can order a conduit body, gasket and cover, pre-assembled, usingone catalog number. T&B’s pre-assembled cast conduit bodies help reducetransactions, eliminate the need for additional stocking bins and provide aneasy inventory reduction. You’ll also have less hassle with managing smallparts in the truck or crib. Best of all, you can be absolutely confident thatthe right parts are in your hands when you need them.
T&B® Conduit Bodies and Covers Feature:• BlueKote internal finish for faster, easier wire pulling
• Epoxy external finish for superior corrosion resistance
• Tapered NPT threads and integral bushings to protect wire insulation
• Bodies are designed with a flat back for more cubic inchcapacity. The flat back also keeps the body more stableduring installation, requiring fewer conduit straps
• T&B Form 7 bodies and covers are interchangeable withCrouse-Hinds and Appleton’s Form 7 bodies and covers
Pre-Assembled Form 7 BlueKote® Conduit Bodies,Gaskets and Covers
Crouse-Hinds is a trademark of Cooper Industries, Inc. Appleton is a trademark of theEGS Electrical Group, a joint venture of Emerson and SPX Corp.
NOTE: BlueKote is registered for conduit bodies but is not registered for a finish or a coating.
and hinge pins provide increased corrosion resistance
• Die cast construction, boxes with securely fastenedmounting plates and industrial designed covers combine to produce a rugged protective enclosure for devices on industrial and OEM applications
• Clean cover edges provide good gasket sealing
• Precision NPT threaded hubs allow trouble-free field installation for rigid or IMC conduit
• Clear UL, CSA and cubic content markings speed approval by inspectors
Standard Materials• Die-cast aluminum alloy A360 with less than
.004% copper content (copper-free)
• Cover hinge pins and springs: Stainless steel
Standard Finish• Aluminum lacquer finish
Listings/Compliances• UL Listed
• Boxes CSA Certified with factory installed ground screw **
• Covers CSA Certified
• Federal Spec. W-C-586
Sample Specifications• Industrial grade FS/FD device boxes and covers shall be
die-cast copper-free* aluminum alloy A360. All conduitstops shall be coined and free of rough edges. Raintightcovers shall have stainless steel springs and hinge pinsand are suitable for use in wet locations with coverclosed (CFSB, CFST and CFSTF suitable for wet locations).Industrial grade FS/FD device boxes and covers shallbe finished with aluminum lacquer. Industrial gradeFS/FD device boxes and covers shall be Thomas & BettsCatalog No. _______
*Less than .004% copper content
**Consult factory for lead time and minimum quantity
FS/FD Aluminum Device Boxes and Covers
AFS
AFSC
AFSS
AFSCC
ADFS
ADFSC
2AFS 2AFSC
2ADFS
Single Gang Boxes Raintight*HUB UNIT STD. WT. LBS.
*Raintight when used with appropriate Thomas & Betts boxes and gaskets. Suitable for use in wet locations with cover closed — NEMA3R.
CFSTF CFSB
CFST
CFSDR
CFSR-G
FS/FD Aluminum Device Boxes and Covers
A-62
United StatesTel: 901.252.8000
800.816.7809Fax: 901.252.1354
Technical ServicesTel: 888.862.3289
www.tnb.com
Single Gang Covers UNIT STD. WT. LBS.
CAT. NO. DESCRIPTION QTY. PKG. PER 100
For Duplex ReceptaclesCDR Duplex receptacle Cover, Box Mount 20 100 11
For SwitchesCTS Switch Cover, Box Mount 20 100 14
NOMINAL MAX. DEVICE UNIT STD. WT. LBS.CAT. NO. SIZE FACE DIA. QTY. PKG. PER 100
For Single Receptacles (Box Mount Only)CRL 19⁄16" 1.600" 20 100 12CRS 13⁄8" 1.395" 20 100 12
STD. WT. LBS.CAT. NO. DESCRIPTION PKG. PER 100
GasketFS-GKV Composition Gasket 100 2
Double Gang Covers — Raintight*UNIT STD. WT. LBS.
CAT. NO. DESCRIPTION QTY. PKG. PER 100
For Two Duplex Receptacles2CWPDR* Two Duplex Receptacle Cover with 2 Spring Doors, 1 10 48
Device Mount
For Single Receptacle2CWPR-M* Single Receptacle Cover, Hole Dia. 21⁄4”, Device Mount 1 10 482CFSR-M* Single Receptacle Cover, Hole Dia. 21⁄4”, Box Mount 1 10 48
For Two Switches2CFST* Plunger Style Switch Cover, Box Mount 1 10 26
Blank2CFSB* Blank Cover, Box Mount 10 50 25
*Raintight when used with appropriate Thomas & Betts boxes, covers and gaskets. Suitable for use in wet locations with cover closed — NEMA3R.
Double Gang Covers UNIT STD. WT. LBS.
CAT. NO. DESCRIPTION QTY. PKG. PER 100
For Two Duplex Receptacles2CDR Two Duplex Receptacle Cover, Device Mount 10 50 24
For Two Switches2CTS Switch Cover, Device Mount 10 50 24
For Switch and Duplex Receptacles2CTDR Switch and Duplex Receptacle Cover, Device Mount 10 50 24
• Accessible wiring chamber providesa convenient location to maintain orchange a system, pull conductorsand make splices
• Unique mounting pads and externalhub designideal for installations ofOEM devices or instruments
Features• Copper-free* aluminum provides
increased corrosion resistance
• Precision cast and machinedsurfaces permit safer wire pulling
• Precision NPT threaded hubs enabletrouble-free field installation for rigidor IMC conduit
• Die cast construction and industrialdesign combine to produce a ruggedprotective enclosure for devices onindustrial and OEM applications
• Clear UL, CSA and cubiccontent markings speed approvalby inspectors
Standard Materials• Die cast aluminum alloy A360
with less than .004 copper content(copper-free)
Standard Finish• Aluminum lacquer finish
Listings/Compliances• UL Listed
• CSA Certified
• Suitable for hazardous locations
• NEMA 4 rated when ordered withO-ring installed
• Federal Spec W-C-586
• CI.I, Div. 1 & 2, Groups C, DCI.II, Div. 1, Groups E, F, GCI.III, Div. 1 & 2
• Explosion-Proof
Dust-Ignition-Proof
Raintight
Wet Locations
Sample Specifications• Outlet boxes for hazardous locations
shall be die cast copper- free*aluminum alloy A360 and suitablefor use in Class I, Groups C, D,Class II, Groups E, F, G and Class IIIareas. All conduit stops shall becoined and free of rough edges.Outlet boxes for hazardous locationsshall be finished with aluminumlacquer. Outlet boxes shall beRed•Dot® Catalog No. __________
• Precision cast and machined surfaces permit safer wire pulling
• Precision NPT threaded hubs enable trouble-free field installation for rigid or IMC conduit
• Die cast construction and industrial design combine to produce a rugged protective enclosure for devices on industrial and OEM applications
• Clear UL, CSA and cubic content markings speed approval by inspectors
Standard Materials• Die cast aluminum alloy A360 with less than
.004 copper content (copper-free)
Standard Finish• Aluminum lacquer finish
Listings/Compliances• UL Listed
• CSA Certified
• Suitable for hazardous locations
• Federal Spec W-C-586
• CI.I, Div. 1 & 2, Groups C, DCI.II, Div. 1, Groups E, F, GCI.III, Div. 1 & 2
• NEMA 3, 4, 7 CD, 9 EFG
• Explosion-Proof
• Dust-Ignition-Proof
• Raintight
• Wet Locations
Sample Specifications• Outlet boxes for hazardous locations shall be die cast
copper-free* aluminum alloy A360 and suitable for use inClass I, Groups C, D, Class II, Groups E, F, G and Class IIIareas. All conduit stops shall be coined and free of roughedges. Outlet boxes for hazardous locations shall be finishedwith aluminum lacquer. Outlet boxes shall be Thomas &Betts Catalog No. __________
Application• Junction for branch conduits in hazardous
locations
• Accessible wiring chamber provides a convenient location to maintain or changea system, pull conductors and make splices
Features• Copper-free* aluminum alloy provides
increased corrosion resistance
• Extra wide 33⁄4" opening provides more handspace for easy access to the wiring chamber
• Precision cast and machined surfaces permitsafer wire pulling
• Large capacity 31 cu. in. chamber providesmore wiring space
• Precision NPT threaded hubs enable trouble-free field installation for rigid or IMC conduit
• Sand cast construction and industrial designcombine to produce a rugged protectiveenclosure for devices on industrial and OEMapplications
• Clear UL, CSA and cubic content markingsspeed approval by inspectors
• Hub spacing enables use of EXFU and EXMU unions
Standard Materials• Box —Sand Cast
aluminum alloy A356. 2-T6
• Cover — Die Cast aluminum alloy A360 with less than .004 copper content (copper-free)
Standard Finish• Aluminum lacquer finish
Listings/Compliances• UL Listed
• CSA Certified
• NEC
• CI.I, Div. 1 & 2, Groups C, DCI.II, Div. 1, Groups E, F, GCI.III, Div. 1 & 2
• NEMA 3, 4, 7 CD, 9 EFG
• Explosion-Proof
• Dust-Ignition-Proof
• Raintight
• Wet Locations
Sample Specifications• Enclosure for hazardous locations. The box
shall be cast copper-free* aluminum alloyA356.2-T6 . Suitable for use in hazardouslocations: Suitable for use in Class I, GroupsC, D; Class II, Groups E, F, G; and Class IIIareas. Enclosures shall be finished withaluminum lacquer. Outlet boxes shall beThomas & Betts Catalog No. ______
• Precision cast and machined surfaces permitsafer wire pulling
• Precision NPT threaded hubs enable trouble-free field installation for rigid or IMC conduit
• Deep slotted cover screws for fasterinstallation
• Clear UL, CSA and cubic content markingsspeed approval by inspectors
Standard Materials• Die cast aluminum alloy A360 with
less than .004% copper content (copper-free)
Standard Finish• Aluminum lacquer finish
Listings/Compliances• UL Listed
• CSA Certified
• Suitable for hazardous locations
• CI.I, Div. 1 & 2, Groups C, DCI.II, Div. 1, Groups E, F, GCI.III, Div. 1 & 2
• NEMA 3, 4, 7 CD, 9 EFG
• Explosion-Proof
• Dust-Ignition-Proof
• Raintight
• Wet Locations
Sample Specifications• Conduit fittings for hazardous locations
shall be die cast copper free* aluminum alloy A360. Suitable for use in hazardouslocations: Class I, Groups C, D; Class II,Groups E, F, G and Class III. All conduitstops shall be coined and free of roughedges. Conduit fittings shall be finishedwith aluminum lacquer. Conduit fittings shall be Red•Dot® Catalog No. __________
*Less than .004 copper content.
EXLB
STD. PKG. CAT. NO. DESCRIPTION QTY.
GUP214-TB Junction Box — 10 Hubs (3⁄4" NPT): 12 in top, 2 in bottom, 1 in each side, 4 in the back
GUP215-TB Junction Box — 6 Hubs (3⁄4" NPT): 12 in top, 2 in bottom, 1 in each side
T&B has developed an innovative new solutionideally suited for gas station contractors and thepetrochemical market — the GUP Explosion-Proof Enclosure. The compact design makes gasstation pumps an ideal application due to spaceconstraints. Two different configurations areavailable and the body is constructed of ductileiron for superior strength. Rely on T&B to deliverthe best products when safety is a concern.Features• Compact design
• O-ring gasket standard for raintightapplications
• Supplied with conduit plugs
— 3 plugs for GUP215-TB
— 7 plugs for GUP214-TB
NEW!NEW!Perfect for the petrochemical industry!GUP Explosion-Proof Enclosure
Copper-free aluminum
Smooth conduitstops
Precision machined threadsand surfaces
Heavy wall construction
Deep slotted screws
Specifications
MaterialsDuctile iron for superior strength (Body)Copper-free cast aluminum (A6) (Cover)Neoprene gasket (O-Ring)Standard FinishDuctile iron — Electrogalvanized and aluminum acrylic paintCopper-free aluminum cover — NaturalListings/CompliancesUL886 ListedCSA Standard C22.2CI.I, Div. 1 & 2, Groups C, DCI.II, Div. 1, Groups E, F, GCI.III, Div. 1 & 2NEMA 3, 4, 7 CD, 9 EFGExplosion-ProofDust-Ignition-ProofRaintightWet Locations
elements between enclosures,fittings or boxes that permitfuture changes to the system in both hazardous and non-hazardous areas
Features• Copper-free* aluminum provides
increased corrosion resistance
• Precision cast and machinedsurfaces permit safer wire pulling
• Precision NPT threaded hubs allow trouble-free fieldinstallation for rigid or IMC conduit
• Clear UL, CSA and cubic content markings speedapproval by inspectors
• Unique concentric ring designinsures critical flame path control
Standard Materials• Die cast aluminum alloy A360
with less than .004 coppercontent (copper-free)
• EXMU nipples are galvanized steel
Standard Finish• Aluminum lacquer finish
Listings/Compliances• UL Listed
• CSA Certified
• Suitable for hazardous locations
• Federal Spec W-C-586
• CI.I, Div. 1 & 2, Groups C, DCI.II, Div. 1, Groups E, F, GCI.III, Div. 1 & 2
• NEMA 3, 4, 7 CD, 9 EFG
• Explosion-Proof
• Dust-Ignition-Proof
• Raintight
• Wet Locations
Sample Specifications• Conduit unions for hazardous
locations shall be die castcopper-free* aluminum alloyA360. Suitable for use inhazardous locations: Class I,Groups C, D; Class II, Groups E,F, G and Class III. All conduitstops shall be coined and freeof rough edges. Conduit unionsshall be finished with aluminumlacquer. Conduit unions shallbe Thomas & Betts® CatalogNo. __________
*Less than .004 copper content.
EXFU
Male and Female UnionsFemale to FemaleCAT. NO. HUB SIZE UNIT QTY. STD. PKG. WT. LBS. PER 100
• Made to order items. Consult factory for lead time and minimum quantities.
A-80
United StatesTel: 901.252.8000
800.816.7809Fax: 901.252.1354
Technical ServicesTel: 888.862.3289
www.tnb.com
ElbowsExplosion-Proof, Dust-Ignition-Proof
ApplicationEYD drain and inspection sealing fittings:
• Restrict the passage of gases, vapors or flames fromone portion of the electrical installation to another atatmospheric pressure and normal ambient temperatures
• Limit explosions to the sealed-off enclosure• Prevent precompression or “pressure piling” in conduit
systems. Drain sealing fittings are installed in verticalconduit runs and at low points in conduit systemsto prevent accumulation of condensate above seal
FeaturesEYD drain sealing fittings include:
• Drain to provide continuous, automatic drainage of condensate
• Large openings with threaded closures to provide easy access to conduit hubs for making dams
• Integral bushings to protect conductor insulation from damage
• Tapered-tapped hubs to ensure ground continuityStandard Materials• Bodies, and inspection or drain covers — Gray iron alloy
and/or ductile iron• Closure for drain — copper-free aluminum or ductile iron• Small closure plug — Gray iron alloy and/or steel• Drain — stainless steel• Removable nipples — steelStandard Finish• Gray iron alloy and ductile iron — electrogalvanized
Class I, Division 1 & 2, Groups A,B,C,D. Class II, Division 1,Groups E, F, G. Class III.
• EYD41 — 101-TBClass I, Division 1 & 2, Groups C,D. Class II, Division 1,Groups E, F, G.Class II, Division 2, Groups F, G.Class III
• UL Standard: 886• CSA Standard: C22.2• NEMA 3, 4, 7 CD, 9 EFG• Explosion-Proof• Dust-Ignition-Proof• Raintight• Wet LocationsSealing Compound and Fibers• Seal A3 (1 lb. can of sealing compound)• Fiber X6 (8 oz. fiber packing)• Seal Kit (1 lb. can of sealing compound
Drains/Breathers for Hazardous LocationsHUB DIMENSIONS (IN.)
CAT. NO. SIZE B
ECD15 1⁄2" .975ECD384 3⁄8" .407ECD284 1⁄4" .327
Application
The Thomas & Betts Universal drain/breather fittings can be used as drains or breathers dependingon the installation.• To use as a drain, the product must be installed in the bottom of the enclosure or the
lowest point where an NPT threaded opening exists. It can also be used in a seal fitting ora “T” conduit body. These must be in a lower section of the conduit system. This will enablemoisture inside the conduit system to drain out
• To use as a breather, installation should be done at the top of an enclosure or in uppersections of conduit systems. This will permit air exchange and keep moisture accumulationinside the conduit system to a minimum, Thomas & Betts recommends the use of at least2 devices (one drain and one breather) for maximum efficency
Application• Limits flames and/or explosions to area within electrical
system where they originate
• Limits pressure piling
• Required by NEC for conduit systems in hazardouslocations 18" from an enclosure housing a heatproducing or arcing device; on 2" and larger systemthat enters an enclosure containing splices; whereverconduit leaves a Class I, Division I area and entersa non-hazardous area
• Precision cast and machined surfaces permitsafer wire pulling
• Precision NPT threaded hubs enable trouble-free field installation for rigid or IMC conduit
• Large opening provides maximum working room forcreating dam and seal pouring to speed up installation
• Compact design permits close construction of parallel conduit runs
Standard Materials• Sealing Fittings: Die cast aluminum alloy A360
with less than .004 copper content (copper-free)
• Sealing Cement
• Fiber: Flame retardant Kaowool Type A fiber
Standard Finish• Aluminum lacquer finish
Listings/Compliances• UL Listed
• CSA Certified
• Suitable for hazardous locations
• Federal Spec W-C-586
• CI.I, Div. 1 & 2, Groups C, DCI.II, Div. 1, Groups E, F, GCI.III, Div. 1 & 2
• NEMA 3, 4, 7 CD, 9 EFG
• Explosion-Proof
• Dust Ignition-Proof
• Raintight
• Wet Locations
Sample Specifications• Sealing fittings for hazardous locations shall be die
cast copper — free* aluminum alloy A360. Suitablefor use in hazardous locations: Class I, Groups C, D;Class II, Groups E, F, G and Class III. All conduit stopsshall be coined and free of rough edges. Sealingfittings for hazardous locations shall be finishedwith aluminum lacquer. Sealing fittings shall beThomas & Betts Catalog No. __________
T&B Red•Dot® sealing cement is used for making seals in sealing fittings. The insulationin the conductors sealed in the cement may be approved thermoplastic or rubber, withor without lead covering. The sealing cement should not be used for insulating.
CharacteristicsT&B Red•Dot® sealing cement is not affected by gasoline, alcohol, acetone, ether, naptha, petroleum, benzol or lacquer solvent.
Preparation(1) Use a clean mixing vessel for each batch.
(2) Thoroughly mix powder before adding water.
(3) Do not use if temperature is below 40° F.
(4) Mix 1 part water to 2 parts cement.
(5) Allow cement to set for 72 hours before use.
Standard Dams(1) Push the conductors away from the filling opening and force them apart so that they
do not touch each other or the walls of the fitting or conduit along their length. If theconductors do touch, the sealing cement will not form a closed path between them.
(2) Force the packing fiber between each conductor and the inside walls. Be sure that thedam is strong enough and tight enough to prevent the considerable weight of the fluidsealing cement from seeping out.
Pouring(1) Pour the mixed cement into the fitting slowly so as not to trap air in the seal.
(2) Replace the close-up plugs to ensure that they engage not less than 5 full threads.
Sealing Cement
Packing Fiber
Vertical Installation for EYVF or EVHF Fittings
SealingCement
Packing Fiber Horizontal EVF Installation
CI.I, Div. 1 & 2, Groups C, DCI.II, Div. 1, Groups E, F, GCI.III, Div. 1 & 2
Approximate Amount of Cement and Fiber Required per Hub.
HUB CEMENT FIBERCAT. NO. SIZE QUANTITY QUANTITY
EYVF-11 1⁄2" 2 oz. 1⁄32 oz.EYVF-22 3⁄4" 3 oz. 1⁄16 oz.EYVF-33 1" 4 oz. 1⁄8 oz.EVHF-1 1⁄2" 2 oz. 1⁄32 oz.EVHF-2 3⁄4" 2 oz. 1⁄32 oz.EVHF-3 1" 4 oz. 1⁄4 oz.EVHF-4 11⁄4" 4 oz. 1⁄4 oz.EVHF-5 11⁄2" 6 oz. 1⁄2 oz.EVHF-6 2" 12 oz. 1 oz.EVHF-7 21⁄2" 15 oz. 11⁄2 oz.EVHF-8 3" 40 oz. 2 oz.EVHF-9 31⁄2" 45 oz. 3 oz.EVHF-10 4" 50 oz. 4 oz.
EXSC
EXPF
CI.I, Div. 1 & 2, Groups C, DCI.II, Div. 1, Groups E, F, GCI.III, Div. 1 & 2
• Achieve tight bends in conduitsystems in confined spaces
• Connect stationary equipment toequipment that moves or vibrates
Features
• Corrosion-resistant — ideal for washdown areas
• Flexible bronze construction witharc-resistant inner sleeve andbrass fittings
• Terminated with two threaded femaleend fittings and male close nipples
• No bonding jumper required
Standard Materials
• Flexible bronze construction witharc-resistant inner sleeve
• Brass fittings
Listings/Compliances
• UL Listed
• CSA Certified
• Suitable for hazardous locations
• 1⁄2" and 3⁄4" Hub Sizes: Class I, Div. 1 & 2, Groups A, B, C, DClass II, Div. 1, Groups E, F, GClass III
• 1" Hub Size: Class I, Div. 1 & 2, Groups C, DClass II, Div. 1, Groups E, F, GClass III
• Wet Locations
• UL886
With their flexible design, T&B® XP Flex Couplings make it easy to achieve tight bends in conduitsystems in confined spaces — or to connect stationary equipment to equipment that moves or vibrates.Their explosion-proof and corrosion-resistant construction mean you can use them with confidencein hazardous and wet locations.
NEW!NEW!
CAT. HUB FLEXIBLE DIMENSIONS (IN.)NUMBER SIZE LENGTH (IN.) A B
Make flexible connections in hazardous locations!XP Flex Explosion-Proof Flexible Couplings
Kopr-Shield® Compound
A-88
United StatesTel: 901.252.8000
800.816.7809Fax: 901.252.1354
Technical ServicesTel: 888.862.3289
www.tnb.com
Good connections are one of the most important aspects of electrical work. Mechanicsknow how much downtime is caused when fluids or oils leak into the raceway system orwhen looking for a weak link in a ground system caused by a high resistance connection.Mechanics also know how much time is spent keeping contacts, switches, lugs and otherconnectors clean or replacing parts because of “green scourge” buildup. Thomas & Bettshas the solution to improve connections made in thousands of electrical and racewayinstallations made each day by electricians everywhere.
Kopr-Shield® compound is a unique homogenized blend of pure, polished colloidal copper,rust and corrosion inhibitors that simultaneously protects, lubricates and enhances theconductivity of the mating surfaces to which it is applied. Extremely adhesive, Kopr-Shield®
compound flows smoothly into uneven contours and voids, making application easy,protection and lubrication complete and positive. A stable compound, it will not settle-out,thin, thicken, harden, or dry out under the most severe environmental conditions.
Kopr-Shield® Compound has excellent temperature characteristics — brushed on at -50˚ F to 250˚ F (other compounds either turn solid or run like water at these extremes).Even at 1800˚ F, Kopr-Shield® remains intact for short terms.
Kopr-Shield® Compound may be used to advantage in all electrical installations. When the environment is hostile to good electrical and mechanical connections,Kopr-Shield® Compound is a must!
Kopr-Shield® by Thomas & Betts meets the requirements of Section 300.6(A) in the 2002 NEC Code for Protection Against Corrosion.
“Where corrosion protection is necessary and the conduit isthreaded in the field, the threads shall be coated with an approved electrically conductive, corrosion-resistant compound.”
Use Kopr-Shield® Compound for Battery Lugs and Cables• Prevention of “Green Scourge” corrosion
• Reduction of resistance
• Ease of terminal installation and removal
Use Kopr-Shield® Compound for Raceways.• Lubrication — ease of assembly and disassembly
• Lubrication — easy installation and removal of fuses
Use Kopr-Shield® Compound for Wiping Contacts, Drum Switches and Slip Rings.• Prevention of galling, burning, pitting and discoloration
• Suppression of arching and dissipation of coronas
• Lubrication for ease of operation
The copper colloidal surface treatment that protects, lubricates and enhances conductivity between all electrical connections.
Kopr-Shield® Compound
CAT. NO. DESCRIPTION STD. PKG. WT. LBS./C
CP8-TB 8 oz. Container with brush 12 64.58CP16 16 oz. Container with brush 12 120.83CP128 1 Gallon can 4 952.00
Kopr-Shield® is a trademark of Jet Lube, Inc.
Jacketed Metal Clad Cable Termination Fittings
Jacketed Metal Clad Cable and Teck CableMetal Clad Cable (Type MC) Ref. NEC Article 334*“Metal Clad Cable Type MC is a factory assembly of one or more conductors,each individually insulated and enclosed in a metallic sheath of interlockingtape, or a smooth or corrugated tube.”
Metal Clad Cable Type MC is rated for use up to 5,000 volts. The NationalElectrical Code permits use of metallic sheath as an equipment groundingconductor.
Metal Clad Cables are available with a variety of phase conductor insulationssuch as crosslinked polyethylene, and silicone rubber ethylene propylene,depending on rated temperature of conductors and working potential.Metallic sheath can be of galvanized steel, aluminum, copper or bronze.A special outer covering such as PVC or Neoprene over metallic sheathis usually provided for environmental protection.
Metal clad cable is not permitted in locations where it could be subjectto physical damage. Metal clad cable can be used exposed, concealed, incable tray, in any approved raceway, and with minor exceptions in hazardouslocations. Type MC cable can also be used for services, feeders, branchcircuits, power, lighting, control and signal circuits.
Use of metal clad cable is permitted in wet locations, or where exposed todestructive corrosive conditions or can be directly buried in earth, concreteor exposed to cinder fills, strong chlorides, caustic alkalis, vapors, chlorineor hydrochloric acids provided the construction of cable, the conductorswithin the metallic sheath, the metallic sheath and protective cover overmetallic sheath comply with requirements enumerated in Sec. 334-3 ofthe National Electrical Code.
Bend radius restrictions are dependent on the size of the cable and thetype of sheath, i.e., smooth, interlocked armor, corrugated sheath or shieldedconductors and varies from 7 times to 15 times cable external diameter.
NEC Article 334 requires that approved fittings be used for termination.Where single-conductor cables carrying alternating current enter a ferrousmetal box or enclosure, procedures described in NEC Section 300-20 mustbe followed to reduce effects of heating due to induced currents. Theseprocedures include recommended arrangements of conductors, cutting ofslots in metal between individual conductor holes, passing of conductorsthrough insulating walls, or use of non-magnetic aluminum sheathed cableand aluminum terminating fittings.
Portions of this section reprinted by permission from NFPA 70, NationalElectrical Code®, National Fire Protection Association, Boston, MA.
Please refer to the following for further details and complete information:
1. NEC Article 334…Metal Clad Cable (Type MC)
2. UL 4, ANSI C33.9…Safety Standards for Type MC Metal Clad Cable
3. UL 514B, Safety Standards for Outlet Boxes & Fittings
4. A-A50552…Federal Specification. Fittings for Cable, Power Electrical& Conduit Metal, Flexible
5. NEMA FM-1…Standards Publication. Fittings and Supports for Conduitand Cable Assemblies
Teck CablesTeck cable derived its name from one of its first users, the Teck-HughesGold Mines in Kirkland Lake, Ontario. Teck 90 is CSA Type designation.Trade designation of this cable is Armored Cable.
Teck cables up to 5,000 volt working potential are manufactured in accordancewith CSA Standard C22.2 No. 131 and are provided with a bare groundconductor and an optional outer jacket. Depending on phase conductor insulationthe cables are designated as Teck 90 (X-LINK) when insulation is cross-linked polyethylene and Teck 90 (EP) when insulation is ethylene propylene.Both cables are rated for 90° C service (dry location) and 75° C (wetlocations). When Teck cable is suitable for installation down to minus 40° Fthe cables are marked Teck 90 (X-LINK) minus 40 or Teck 90 (EP) minus 40.
Over 5,000 volts working potential Teck cables are manufactured in accordancewith IPCEA standards and are certified by CSA. Cables are provided with orwithout ground wire as required.
Teck cables with outer jacket may be used for exposed or concealed wiring inwet or dry locations, indoors/outdoors and in corrosive environments. Teck cablesare suitable for use in ventilated, non-ventilated and ladder-type cable troughs,in ventilated flexible cable ways in both dry and wet locations. Teck cable withouter jacket is suitable for direct earth burial and for Class II Division 2, ClassIII Division 1 & 2 hazardous locations per Canadian Electric Code.
Some of the features of Teck cable are its flexibility and ease of installation.Absence of dead air space within cable increases heat transfer and minimizecondensation. Overall protective covering provides good environmental protection.
Bend radii for permanent training during installation usually varies between7 times to 12 times the cable diameter depending on cable constructionand manufacturer’s recommendations. Larger radii bends are required forother conditions.
Section 12-3028 of the Canadian Electric Code requires that the terminatingfittings used must provide adequate strain relief to terminal connectionsand ensure electrical continuity without injury to non-metallic sheath.Continuity is mandatory whether or not the armor is used as a groundingconductor. Except for dry locations free from corrosive atmosphere, thenon-metallic jacket is not permitted to be stripped back to a point wherearmor is exposed after installation.
Where single conductor cables carrying 200 amps or more enter metalboxes through separate openings, certain precautions are required to preventoverheating of the metal by induction. Use of non-ferrous or non-metallic boxconnectors, locknuts and bushings and installation of non-magnetic panelinserts is suggested in the code.
Please refer to the following for further details and complete information:
Please Note: The materials herein, whether relating to the National Electrical Code, the Underwriters Laboratories, Inc. listing, to industry practice or otherwise, are not intendedto provide all relevant information required for use and installation of our products. Refer to applicable codes, instructions and industry specifications prior to installation or use.
A-89
United StatesTel: 901.252.8000
800.816.7809Fax: 901.252.1354
Technical ServicesTel: 888.862.3289
www.tnb.com
Jacketed Metal Clad Cable Termination Fittings
STAR TECK EXTREME® — STE/STEX Series Cable Fitting
Application• Provides means for passing jacketed
metal clad cables through a bulkheador enclosure in industrial andhazardous areas. (These fittings aresuitable for hazardous areas whenused with T&B sealing compound.)
• Forms a mechanical grip and waterand/or oil-resistant termination
• Provides grounding continuityof cable armor
Features• Powergrip grounding ring
• Removable armor-stop for greatercable ranges
• Built-in sealing device
• Elastomeric collar ring/ bushing for greater cable ranges
• Built-in jacket stripping gaugeon gland nut
• Gland nut can be tightened with hammer and screwdriver
Range• STAR TECK EXTREME® fittings are
designed to accommodate a broadrange of cables. Each hub rangeoverlaps the adjacent hub range,thereby minimizing the possibilityof mismatched cables and fittingsin the field. They are available in hub sizes from 1⁄2" to 4" and willhandle outer jacket diameters form 0.525" to 4.340".
Materials• Aluminum is standard material
• Add suffix “S” for steel withzinc plating
• Add suffix “PVC” for corrosionresistant PVC coating
• Add suffix “SS” for stainless steel material
Cable Type• JMC, MC-HL, Teck
Environment Classification• STE* Series
–Ordinary Location
–Class I, Division 2†
• –NEMA 4, 4X (stainless steel), 6P
• –STE050 — STE200
NEMA 6P
• –STE250 — 400
NEMA 4
• –STE050 — 400
NEMA 4X (stainless steel)
• STEX** Series
–Class I, Division 1, Groups A, B, C, D
–Class II, Division 1, Groups E, F, G
–Class III
–NEMA 4, 4X (stainless steel), 6P
• UL Listed for Direct Burial when made from stainless steel material
• Suitable for use in wet locations andconcrete tight (steel) applications perUL 514B
• UL File No. E82038/E38947
• CSA File No. LR638/LR23086
* These fittings are suitable for Class I hazardous locationswhen used in combination with a certified Class Ihazardous location sealing fitting.
** May be used in hazardous areas with approved MC-HLor Teck cable (or equal) when installed in accordancewith NEC/CEC requirements.
Not applicable to all STEX series.
The STAR TECK® STE cable fitting series is designed for optimum integrity in ordinary applications.The STEX series is specially designed for classified hazardous areas. Both are designed to stand up to the harshest and most corrosive environment.
A-90
United StatesTel: 901.252.8000
800.816.7809Fax: 901.252.1354
Technical ServicesTel: 888.862.3289
www.tnb.com
Greater CableRange + FewerPart Numbers = Less Inventory!
Greater CableRange + FewerPart Numbers = Less Inventory!
Jacketed Metal Clad Cable Termination Fittings
STAR TECK EXTREME®Jacketed Metal-Clad Cable FittingsDIMENSIONS (IN.) SEALING COMPOUND
HUB STRIP GLAND CABLE RANGE CABLE RANGE A1: THROAT A2: THROAT B C REQUIREDCAT. SIZE LENGTH TORQUE OVER JACKET (IN.) OVER ARMOR (IN.) DIA. MIN. DIA. MIN. OVERALL MAX. SC65 SC4-KITNO. NPT (IN.) (IN.-LB.) MIN. MAX. MIN. MAX. W/END STOP WO/END STOP O.D. PUTTY (G) LIQUID (CC)
STE Series Ordinary STEX Series Hazardous Locations
Sealing Compounds — Used for Hazardous LocationsCAT. NO. DESCRIPTION VOLUME
SC65 Putty Type Sealing Compound 60 gramsSC4-KIT Liquid Type Sealing Compound for use in high wire density applications 2.8 fl. oz. (66 cc)
(5 or more wires)
To specify other material, add the appropriate suffix to the category number.
DESIRED MATERIAL SUFFIX EXAMPLE
Aluminum fitting with grounding lock nut GRL STE-050GRLSteel with zinc plate S STE-050SAluminum with PVC coating PVC STE-050PVCSteel with PVC coating S-PVC STE-050S-PVC
* These products are UL Listed Watertight NEMA Type 6P
** UL tested for data cables
# Does not have a removable armor stop.
A-91
United StatesTel: 901.252.8000
800.816.7809Fax: 901.252.1354
Technical ServicesTel: 888.862.3289
www.tnb.com
Jacketed Metal Clad Cable Termination Fittings
STAR TECK® Jacketed Metal-Clad Cable FittingsOverlapping range of sizes. Star Teck® jacketed metal-clad cable fittings are designed to accommodatea broad range of cables, thereby minimizing the possibility of mismatched cables and fittings in the field.
Application• Provide means for passing armored,
metal clad, jacketed cables througha bulkhead or enclosure in hazardousareas (these fittings are suitable forhazardous areas when used withT&B sealing compound)
• Form a mechanical grip and waterand/or oil-resistant termination
• Provide grounding continuityof cable armor
Cable Type• JMC, MC-HL, Teck
Features
Easy Installation
• Exclusive power-grip. Provides a gripthat’s high up on the cable — not onthe first convolution — so strip lengthand cutting of cable are not as critical
• Power-Grip grounding ring is non-magnetic stainless steel. Provides360° long-term dependablegrounding. It makes immediatecontact with the cable
Watertight
• Tapered bushing. Cone shapedto provide a secure, tight fit whileeliminating cupping or water invertical installations
Easy to Install in Tight Spaces
• Low profile gland nut fits tightspaces. Has grooves for screwdriverinstallation, and flats for a wrench.Durable and reusable with funnelentry for easy cable insertion
Materials• Aluminum is standard material
• Add suffix “S” for steel with zinc plating
• Add suffix “PVC” for corrosionresistant PVC coating
• Add suffix “SS” for stainless steelGrade 316 material (1⁄2"–2" sizes)
Environment Classification• Suitable for hazardous locations.
Class I Div. 2; Class II Div. 2; Class III.Where explosion proof or dust prooffittings are required by code useSTAR TECK XP® fittings (STX Series)
• NEMA 4
• Suitable for use in wet locationsand concrete tight (steel) applicationsper UL 514B
• UL File No. E82038/E38947
• CSA File No. LR638/LR23086
Range• Available in hub sizes from 1⁄2" to 4",
and will handle outer jacketdiameters from 0.525" to 4.340"
WatertightTapered bushing.Cone shaped toprovide a secure,tight fit whileeliminatingcupping or waterin verticalinstallations.
Easy Installation.Exclusive power-grip. Provides agrip that’s high upon the cable —not on the firstconvolution —so strip length andcutting of cableare not critical.
DependableGrounding.Power-Gripgrounding ringis non-magneticstainless steel.Provides 360°long-termdependablegrounding. It makesimmediatecontact withthe cable.
Easy to Installin tight spaces.Low profile glandnut fits tight spaces.Has grooves forscrewdriverinstallation, andflats for a wrench.Durable andreusable withfunnel entryfor easy cableinsertion.
A-92
United StatesTel: 901.252.8000
800.816.7809Fax: 901.252.1354
Technical ServicesTel: 888.862.3289
www.tnb.com
Jacketed Metal Clad Cable Termination Fittings
HUB CABLE RANGE OVER CABLE RANGE OVERCAT. SIZE JACKET (IN.) ARMOR (IN.) DIMENSIONS (IN.)NO. NPT MIN. MAX. MIN. MAX. A B* C
Suggested specifications for metal-clad cable fitting.
1. All metal-clad cable fittings for jacketed interlocked armor cable or continuous corrugated cable shall be approved by a nationally recognized testing laboratory, inspection agency or product evaluation organization.
2. Where corrugated-jacketed metal-clad cable exposed to intermittent or continuous moisture is terminated into a threaded opening, the fitting shall be watertight type furnished with:
a. An elastomeric beveled bushing.
b. A funnel entry, splined gland nut.
c. A non-magnetic stainless steel grounding device with dual grounding action.
d. A taper threaded hub.
e. A hexagonal body and gland nut as manufactured by Thomas & Betts (aluminum series ST050-464).
3. Where cable is terminated into a threadless opening, a suitable moisture-resistant elastomeric gasket as manufacturedby Thomas & Betts, series 5262, shall be provided between the outside of enclosure and fitting shoulder.
4. With single conductor cable and/or in corrosive environments, aluminum fittings such as Thomas & Betts series ST050-464shall be installed.
Class I Div 2; Class II Div. 2; Class III. Where explosion-proof or dust-ignition-proof boxes are required by Teck, fitting mustbe used in conjunction with an approved sealing fitting.
Retaining ring(stainless steel)
Bushing (neoprene)
Gland nut (aluminum)
Grounding ring(stainless steel)
Body (aluminum)
• Overlapping sizes minimizepossibility of mismatched cables and fittings in the field
• Available in hub sizes from 1⁄2" to 4",handling outer jacket diameters from0.525" to 4.34"
• Suitable for hazardous locations(Class 1 Div. 2; Class II Div. 2; Class III)
• Where explosion-proof or dust-proof boxes are required by code, use STAR TECK XP®
fittings (STX050-462 Series)
B
C
A
Overlapping range of sizes accommodates a broad range of cables!
STAR TECK® Jacketed Metal-Clad Cable Fittings for Ordinary Locations
A-93
United StatesTel: 901.252.8000
800.816.7809Fax: 901.252.1354
Technical ServicesTel: 888.862.3289
www.tnb.com
Jacketed Metal Clad Cable Termination Fittings
STAR TECK XP® JacketedMetal-Clad Cable Fittingsfor Hazardous Locations
Easy installation saves time, money!
1. Prepare cable
3. Tighten gland nut 4. Pot cable (using liquid or putty)
5. Install hub on enclosure 6. Insert cable and tighten red union
2. Install STAR TECK XP® on cable
Sealing chamber is easierto fill, requires less sealingcompound — saves time,material. Flame path isoptimally designed to enableeasy insertion into hub.Quick-turn lock securesassembly during installation.
Hub has hexagonal shapefor dependable tool grip.
Internal splinesenable installerto tighten glandnut either on oroff enclosure.
Union features twist-on action foreasy connection and disconnection;red color ensures high visibility,easy recognition. Union also servesas a “puller” during disassembly.
Low profile gland nutfits tightest spaces.Has grooves forhammer/screwdriverinstallation and flatsfor wrench-gripping.Durable and reusablewith funnel entry foreasy cable insertion.
Exclusive Power Grip. Provides gripthat’s high up on cable armor —not on first convolution — soprecise cable preparation is notcritical. Non-magnetic stainlesssteel Power Grip grounding ringensures 360° long-term dependablegrounding. It provides phenomenaltensile pullout resistance.
Tapered bushing. Cone-shaped to provide secure,tight fit while eliminatingcupping of water in verticalinstallations.
Copper-free construction.All aluminum body and glandnut resist corrosion, oxidation.
Application• Provide means for passing armored, metal clad, jacketed
cables through a bulkhead or enclosure in hazardous areas(these fittings are suitable for hazardous areas when usedwith T&B sealing compound)
• Form a mechanical grip and water and/or oil-resistanttermination
• Provide grounding continuity of cable armorCable Type• JMC, MC-HL, Teck
Features• Sealing chamber is easier to fill, requires less sealing
compound — saves time, material. Flame path is optimallydesigned to enable easy insertion into hub. Quick-turn lock
• Internal splines
• Union features twist-on action; red color for high visibility
• Exclusive Power Grip. Provides grip that’s high up on cable armor Non-magnetic stainless steel Power Gripgrounding ring
• Low profile gland nut
Materials• Aluminum is standard material
• Add suffix “S” for steel with zinc plating
• Add suffix “PVC” for corrosion resistant PVC coating
• Add suffix “SS” for stainless steel material
Environment Classification
• Suitable for hazardous locations. Class I Div. 2; Class II Div.2; Class III. Where explosion proof or dust proof fittings arerequired by code use STAR TECK XP® fittings (STX Series)
• NEMA 4
• Suitable for use in wet locations and concrete tight (steel)applications per UL 514B
• UL File No. E82038/E38947
• CSA File No. LR23086
Range• Available in hub sizes from 1⁄2" to 4", and will handle
outer jacket diameters from 0.525" to 4.185"
A-94
United StatesTel: 901.252.8000
800.816.7809Fax: 901.252.1354
Technical ServicesTel: 888.862.3289
www.tnb.com
Jacketed Metal Clad Cable Termination Fittings
STAR TECK XP® Jacketed Metal Clad Cable Fittings for Hazardous Locations
SEALING COMPOUNDCABLE CABLE REQUIRED
HUB RANGE OVER RANGE OVER DIMENSIONS (IN.) SC65** SC4-KIT**SIZE JACKET (IN.) ARMOR (IN.) A PUTTY LIQUID
CAT. NO. NPT MIN. MAX. MIN. MAX. MIN. B* C (G) (CC)
** 1 unit of SC65 putty type sealing compound contains 60 g. 1 unit of SC4-Kit liquid type sealing compound contains 66 cc and includes a dispensing syringe and fiber damming material.
CAUTION: STAR TECK XP® fittings must be installed with Thomas & Betts catalog numbers SC4-Kit or SC65 sealing compound (purchase separately). See installing instructions.
Sealing CompoundsCAT. NO. DESCRIPTION VOLUME
SC65 Putty Type Sealing Compound 60 gramsSC4-KIT Liquid Type Sealing Compound for use in high wire density applications 2.8 fl. oz. (66 cc)
(5 or more wires)
Hub(aluminum)
Grounding Ring(stainless steel)
Gland Nut(aluminum)
Bushing(elastomer)
Retaining Ring(stainless steel)
B
CA
UL Connectors when Used with Putty TypeListed or Liquid Type Compound For:1⁄2 thru 3" Class I Div. 1 Groups A, B,
C, D
Class II Div. 2 Groups F, G
Class III
Enclosure Type 4
Connectors when Used with Putty Type or Liquid Type Compound31⁄2" & 4" Class I Div. 1 Groups B, C, D
Class II Div. 2 Groups F, G
Class III Enclosure Type 4
CSA Certified For:Class I Division Groups A, B,
1 and 2 C, D
Class II Division Groups E, 1 and 2 F, G
Class III, SL (Integral Seal)Enclosure Type 4
A-95
United StatesTel: 901.252.8000
800.816.7809Fax: 901.252.1354
Technical ServicesTel: 888.862.3289
www.tnb.com
Jacketed Metal Clad Cable Termination Fittings
Spin-On® Series II Connectors and Accessories
OPTIONAL HUB CABLE RANGE CORROSIONSIZE OVER ARMOR DIMENSIONS (IN.) RESISTANT BOOT
In corrosive environments, the T&B neoprene boot providesmaximum corrosion protection to the connector. Simplymatch the connector hub size to the boot hub size to selectthe proper boot (NB Series).
A-96
United StatesTel: 901.252.8000
800.816.7809Fax: 901.252.1354
Technical ServicesTel: 888.862.3289
www.tnb.com
ConnectorAluminum
Jacketed Metal Clad Cable Termination Fittings
Spin-On® X Connectorsfor Hazardous Locations
• Each SPIN-ON® X catalog number is a complete compound-filled connector kit
• 3-piece construction — gland/body/insert with O-ring
• Red anodized gland identifies hazardous location fitting
• Compact size — overall length is 2⁄3 less than conventional fitting
• Installation time is 50% less than conventional
• Full tapered hub threads for gas-tight thread engagement
• Machined aluminum construction for corrosion resistance
• Neoprene boots available for additional corrosion protection
• For control cable applications, order liquid compound separately
Install a complete gas-blocked connector in a hazardous location!
Suffix Cat. No. with S for steel, B for brass.
SPIN-ON ® X is UL Listed for: Class I, Div. 2, Groups A, B, C, & D in 3⁄4", 1", 11⁄4", 11⁄2", 2", 2 1⁄2" Hub sizes. Class I, Div. 2,Groups C & D in 3", 3 1⁄2", and 4" Hub sizes. The entire line is UL listed for Class II, Div. 2, Groups F & G and Class III.CSA certified through 4" Hub size for Class I, Groups A, B, C, D; Class II, Groups E, F, G; and Class III.
UL File No. E82038
CSA File No. LR23086
Liquid Type Sealing CompoundsCAT. NO. DESCRIPTION VOLUME
SC65 Putty Type Sealing Compound 60 gramsSC4-KIT Liquid Type Sealing Compound for use in high wire density applications 2.8 fl. oz. (66 cc)
(5 or more wires)
A-97
United StatesTel: 901.252.8000
800.816.7809Fax: 901.252.1354
Technical ServicesTel: 888.862.3289
www.tnb.com
Spin-On® X Connectors for Hazardous LocationsSEALING COMPOUND
HUB CABLE RANGE REQUIREDSIZE OVER ARMOR DIMENSIONS (IN.) SC65** SC4-KIT**
For stainless steel (316), replace AL with SS6 (up to 1" only)
Introducing the Silver Grip® Tray/Cord Fitting — the safe, yet cost-efficientchoice for increased safety when terminating portable cord and tray cable inhazardous locations. Designed for use in Class I, Gas and Vapor environments,the Silver Grip® Tray/Cord Fitting provides efficient strain relief for cablesentering enclosures and raceways, and for cords used on portable equipment.
• Now available in stainless steel in hub sizes from 1⁄2" to 1"
• Corrosion-resistant, non-magnetic aluminum construction
• Tapered neoprene bushing and O-ring seal out moisture and dirt ingress
• Chuck grip provides high mechanical pull-out performance.Exceeds applicable requirements
• Hand-tightens — no tools required
*When cord will not fit through body, stripcord jacket and trim fillers if required. Insertcable, ensuring the outer jacket reaches theend of the bushing as shown. Tighten glandnut onto body.
MaximumOpening
GlandNut
ChuckGrip
Bushing
Body
O-Ring
Increase safety for hazardous locations.Silver Grip® TCF® Series — Tray/Cord Fitting
ApplicationsTray Cable: Complies with IEC requirements for Class I, Zone 2locations when used with enclosures containing no arcing or sparkingdevices. For enclosures with arcing or sparking devices, TCF® fittingsmust be used in combination with a certified Class I hazardouslocation sealing fitting.
Portable Cord: Complies with IEC requirements for Class I, Zone 1locations when used with enclosures containing no arcing or sparkingdevices. For enclosures with arcing or sparking devices, TCF® fittingsmust be used in combination with a certified Class I hazardouslocation sealing fitting.
NOTE: Tray cable is not suitable for use in Zone 1 locations. Portablecord can be used in Zone 1 applications only when installed onportable equipment.
• CSA File Number LR4484
• Class 4418-03 Fittings for Hazardous Locations
• Class 4418-03 Fittings for Hazardous Locations —Certified to U.S. Standards
• Class I, Zone 1, AEx e ll
A-98
United StatesTel: 901.252.8000
800.816.7809Fax: 901.252.1354
Technical ServicesTel: 888.862.3289
www.tnb.com
Now Availablein Stainlessup to 1"
Now Availablein Stainlessup to 1"
Tray Cable Fittings
Tray Cable ConnectorsHUB SIZE A (IN.) B (IN.) CABLE RANGE
NOTE: When installed with the two-part epoxy in the intended manner, the fittings are suitable for the following hazardous locations:3⁄4" thru 21⁄2" — Class I Div. 2, Groups A, B, C, D
Class II Div. 2, Groups F, G
3" thru 4" — Class I Div. 2, Groups C, DClass II Div. 2, Groups F, G
* CSA Certified only (not UL Listed)
C
B
A
The T&B TC Series Tray Cable ConnectorThe Thomas & Betts TC Series of connectors are designed specifically for transitioning tray cable fromhorizontal cable tray to terminations in enclosures. The precision machined aluminum interiors are ideallysuited for use with sunlight-oil resistant cable.
Application• Provides means for passing TC type
cable from cable tray installations intoan enclosure or threaded bulkhead
Tray Cable Type• TC (rated for 90° C cable)
Features• Precision machined parts
• Full tapered hub threads
• Gas tight thread engagement
Materials• Body, gland nut and insert
copper-free aluminum
Environment Classification• Ordinary locations
• Class I, Division 2†, Groups A, B, C, D (3⁄4"–21⁄2")
• Class I, Division 2, Groups C, D (3"–4")
• Class II, Division 2, Groups F, G
Range0.225"–3.790"
• Suitable for use with sunlight-oilresistant tray cable
• Suitable for 90° Cable
• CSA Certified — Class I Div. 2,Groups A, B, C, DClass II Div. 2,Groups E, F, GClass III
• “SL” Integral Seal
A-99
United StatesTel: 901.252.8000
800.816.7809Fax: 901.252.1354
Technical ServicesTel: 888.862.3289
www.tnb.com
Electrical Metallic Tubing (EMT) Fittings
Series 5123 InsulatedEMT Connector (Raintight)
(Compression Type)
Series 5120EMT Coupling (Raintight)
(Compression Type)
Series 4176Pipe Straps
Series 1350Pipe Spacers
Series 106Bonding Locknut
Series TK121-EEMT Coupling (Concrete tight)
(Set Screw Type)
Series HT-221Combination Coupling
(Concrete tight) Rigid/IMC to EMT(Set Screw Type) Zinc Die Cast
• Ferrous Electrical Metallic Tubing (EMT) shall be of the hot dipped galvanized typeconforming to applicable specifications WW-563/ANSI C33.98/ANSI C80.3/UL 797/CSA C22.2 No. 83. E.M.T. protected solely by enamel shall not be used
• Where lengths of EMT are coupled together or connected to boxes or enclosures or whereEMT is coupled to threaded rigid metal conduit or IMC, fittings approved for intended applications shall be used, and:
(1) Shall be of rugged steel/malleable iron construction electro zinc platedinside/outside including threads. Connector throat shall be bushed with a nylon insulator
(2) Shall be of raintight type for installationsexposed to weather or wet locations suchas Thomas & Betts series TC112A-RT and TK112A-RT
(3) Shall be of concrete tight type forinstallations in poured concrete such as Thomas & Betts series TC121, TC721, or TK121, 5123, 5120, and 530
• Raintight type fittings may be substituted for concrete tight application.
• Where electrical metallic tubing andassociated fittings are used as part of equipment grounding system:
(1) A bonding type locknut such as Thomas & Betts series 106 shall be installed where hub type fitting terminates into a threadless opening
(2) Compression ring type fittings such asThomas & Betts series 5123 and 5120shall be used for terminating and coupling
• EMT shall be securely fastened in place atintervals as specified by the code using straps,hangers and other supporting assemblies asindicated on plans, and as manufactured byThomas & Betts, series 4176 straps. In wetlocations or where supporting surfaces are of absorbent materials vertical and horizontalruns of conduit shall be firmly supported suchthat there is at least 1⁄4" air space betweenconduit and supporting surface
• Spacers and supporting straps shall be ofrugged malleable iron or steel construction hot dipped galvanized and conforming torequirements of Canadian StandardsAssociation Standard C22.2 No. 18 asmanufactured by Thomas & Betts, series 4176 straps and series 1350 spacers
Suggested Specifications for Electrical Metallic Tubing (EMT) Fittings
A-100
United StatesTel: 901.252.8000
800.816.7809Fax: 901.252.1354
Technical ServicesTel: 888.862.3289
www.tnb.com
Electrical Metallic Tubing (EMT) Fittings
Application• To connect and effectively bond electrical
metallic tubing to a box or an enclosure
• To provide a rain tight connection between tubing and the connector
• To couple ends of tubing
Features• Rugged all steel construction
• Rings designed to positively bond conduit to fitting; uniquelocknut design provides effective bond between fitting andbox or enclosure; ground continuity is ensured
• Nylon insulator firmly secured in place — protectsconductors, reduces wire pulling effort and prevents thread damage in handling
• Locknuts are designed with extended reach to lock fitting on to a thin box or an enclosure
• Locknuts tighten without deformation; will not vibrate loose
* Gaskets sold separately. In some jurisdictions, sealing gaskets are not required when installed in a threaded opening. Also, a connector assembled in the bottom of a box or enclosure may beconsidered by code “to be located (placed) so that water will not enter the enclosure at the knockout interface” (NEC 314.15 (A)). In this instance, the sealing O-ring may not be required. Consultwith the local authority having jurisdiction.
Raintight EMT Compression Fittings featurea distinctive design and vibrant gland nutcolor, enabling inspectors to visually inspectconformance from a distance. There's noclose-up inspection required!
L Max
L Max
B Max
HAcrossPeaks
BAcrossPeaks
A-102
United StatesTel: 901.252.8000
800.816.7809Fax: 901.252.1354
Technical ServicesTel: 888.862.3289
www.tnb.com
A
Electrical Metallic Tubing (EMT) Fittings
Insulated for safe, simple installation in cramped locationsor tight corners!
• Ideal for applications where largeradius conduit elbows won’t fit orwould appear unworkmanlike
• Shoulders on body of 1⁄2" size arehex-shaped to provide positiveholding for standard installationtools
• Malleable iron construction
• UL rated 105°C
Short Elbows —Insulated*
Ideal for cramped locations or tight corners!Short Elbows — Malleable Iron*
For connecting EMT to threaded rigid and intermediate metal conduit.Combination Coupling — Steel*
AcrossCorners
HUB DIMENSIONS (IN.)CAT. NO. SIZE A B
530-TB 1⁄2" 13⁄8 11⁄16
531 3⁄4" 11⁄2 111⁄32
532 1" 119⁄32 121⁄32
UL File No. E-09043
CSA File No. 2884
HUB DIMENSION (IN.)CAT. NO. SIZE A B C
4230 1⁄2" 17⁄16 1s 7⁄16
4231 3⁄4" 111⁄16 119⁄321⁄2
4232 1" 17⁄8 127⁄325⁄8
4233 11⁄4" 23⁄4 215⁄3211⁄16
4234 11⁄2" 31⁄16 23⁄4 11⁄16
4235 2" 33⁄8 35⁄1611⁄16
UL File No. E-09043
CSA File No. 2884
HUB DIMENSION (IN.)CAT. NO. SIZE A B C
4240 1⁄2" 17⁄16 1s 7⁄16
4241-TB 3⁄4" 111⁄16 119⁄321⁄2
4242 1" 17⁄8 127⁄325⁄8
4243-TB 11⁄4" 23⁄4 215⁄3211⁄16
4244 11⁄2" 31⁄16 23⁄4 11⁄16
4245 2" 33⁄8 35⁄1611⁄16
UL File No. E-09043
CSA File No. 2884
For XJG Conduit ExpansionCouplings for EMT see page A-25.
• Shoulders on body of 1⁄2" size are hex-shaped to providepositive holding for standard installation tools
• Malleable iron construction
A-103
United StatesTel: 901.252.8000
800.816.7809Fax: 901.252.1354
Technical ServicesTel: 888.862.3289
www.tnb.com
Electrical Metallic Tubing (EMT) Fittings
HUB DIMENSIONS (IN.)CAT. NO. SIZE A B C (BOLT HOLE)
• Elongated bolt hole makes alignmenteasy, even when holes in mountingsurface are out of alignment
• Available in 1⁄2" to 2" sizes
Oval Hole forScrew Size (C)
• High reinforcing ribs on each sideincrease strength and reduce weight
• Hot-dipped galvanized finish
Designed to fit eachsize of conduit snugly!
Pipe Straps —Malleable Iron
Eliminates the need for costly offset-bending of conduit to preventcorrosive moisture traps when conduit is mounted directly to a surface!
Pipe Spacers
• Used with T&B conduit straps topermit space between conduit andmounting surface
• Pre-mountable and stackable toeliminate offsetting
• Malleable iron construction withhot-dipped galvanized finish
1350 1351
A-104
United StatesTel: 901.252.8000
800.816.7809Fax: 901.252.1354
Technical ServicesTel: 888.862.3289
www.tnb.com
Liquidtight Flexible Metal Conduit Fittings
Our Liquidtight Line Is the End-All for Liquidtight Dust-Tight Connections.
A-105
United StatesTel: 901.252.8000
800.816.7809Fax: 901.252.1354
Technical ServicesTel: 888.862.3289
www.tnb.com
All our high-performance products are designed to deliver excellentreliability as well as ease of installation in virtually any application.And you benefit from our expertise through our liquidtight anddust-tight connections available for a variety of conduits as wellas portable cord.
Thomas & Betts offers the largest and most technologically advancedline of liquidtight fittings in the industry, including connectors for highly
specialized applications such as power and petrochemical plants,paper mills, robot manufacturers, packaging equipment, machine toolbuilding, and other OEM and MRO applications. At Thomas & Betts,we integrate the latest manufacturing technologies with the highest quality materials available. So you can be assured of reliable,liquidtight products that offer improved on-the-job performanceand reduced installation time and costs.
Liquidtight Flexible Metal Conduit Fittings
Gland deflects water away from connector andprevents “pooling” of moisture. Look for the distinctive“Pumpkin” appearance of the gland nut.
Self-Cleaning Threads inside gland nut keep dirtand grime out of the threads as you tighten.
Double Beveled Sealing Ring is designed with fiveunique sealing mechanisms and cannot be installedbackwards. Manufactured of high-temperaturerated thermoplastic to demanding specifications.Look for the unique T&B blue color ensuring thehighest quality fitting.
Safe Edge® Ground Cone provides superior bonding,stronger pullout, easy threading and conductorprotection. Look for the distinctive “ski slope”appearance within the “pumpkin” gland nut.
Heat-Curled Insulator provides excellent wireprotection and easier glide of conductors through and into the fitting. In addition, the heat-curled finish gives the insulator more strength than glue-in insulators. Look for the unique T&B blue color ensuring the highest quality fitting.
Precision Machined Rolled Threads provide smooth, easy installations.
Tempered Cast Locknut with Teeth providessuperior strength and electrical bonding and canbe installed without a wrench in the enclosure.
T&B makes liquidtight fittings for demanding situations.Liquidtight Flexible Metal Conduit Fittings
Add suffix -GR to the fitting catalog number to order the Revolver® Grounding version.
T&B’s Heat-CurledInsulator
Competitor’s Glue-In Insulator
Revolver® Grounding FittingSaves time and money using our infinitelyadjustable rotating ground lug. Simplyalign the lug in your preferred position and tighten the gland. You’ll never need to worry about tightening it into an inconvenient position again.
A-106
United StatesTel: 901.252.8000
800.816.7809Fax: 901.252.1354
Technical ServicesTel: 888.862.3289
www.tnb.com
Liquidtight Flexible Metal Conduit Connectors
Liquidtight Flexible MetalConduit Fittings
Thomas & Betts Liquidtight fittings for flexiblemetal conduits are suitable for a wide range of installations, including heavy industrialapplications. Our Liquidtight fittings are designed to stand up to demanding, wet or corrosive environments, including power and petrochemical plants, paper mills, and anywhere high performance is a requirement.
Liquidtight Connectors
The Revolver® Externally Grounded FittingThe Revolver liquidtight grounding fitting isour latest breakthrough in convenience to savetime and money on the job while deliveringa quality connection.
The grounding lug of the new Revolver connectorcan be rotated in a full circle for convenientpositioning that doesn’t change when you tighten it. Plus, it’s available for the first time in aluminum. It’s the newest innovation inThomas & Betts’ versatile line of LiquidtightConnectors — fittings you can count on for liquidtight and dust-tight connections, becauseall our products revolve around your needs.
Chase®-Style FittingsWhere space is tight, our Chase fittings enablefor compact connections within an enclosure.
Sealing GasketsThomas & Betts sealing gaskets are resistant tooil, coolants and hydraulic fluids as well as water,with a stainless steel retaining clip that ensuresa quality seal. They’re the ideal match to ourLiquidtight connectors for a safe and secure seal.
When non-metallic, Type A or EFC conduits arecalled for, Thomas & Betts’ XTRA FLEX® System has our outstanding Bullet fittings and conduits for liquid- and dust-tight connections.
Bullet Fittings• Feature one-piece construction and
a captive O-ring for ease of installation
• Provide a positive seal between the conduit and the connector
• Has tapered thread hub and sealing O-ringfor a tight seal to the box or other enclosure
• Are constructed of nonburning, nondripping thermoplastic for high strength chemical resistance
• Feature a smooth insulated body for maximum dielectric strength
• Include a complete range of flexible, non-metallic conduits — includingboth smooth and corrugated varieties — to complete our XTRA FLEX® System
Features of Thomas & BettsLiquidtight Fittings include:• Safe Edge® ground cone design that
accepts variations in raceway convolutionsand provides a positive bond
• Continuous sealing ring that completelysurrounds the conduit to ensure a liquid-tight seal
• Zinc chromatic plating for longer life and exceptional appearance
• The broadest liquid-tight line in the industry,including PVC coated, externally grounded,aluminum series, Chase® style, nonmetallicBullet series, wire mesh grips and more
* Suitable for hazardous locations use in Class I, Div. 2;Class II, Div. 1 and 2; Class III, Div. 1 and 2, where generalpurpose equipment is specifically permitted per NECSection 500-2(a).** 3⁄8" Conduit Fitting has 1⁄2" hub.† UL Listed as grounding means under NEC 351-7.‡ Not UL Listed.
Blue is a trademark color of Thomas & Betts.
Note: UL Listed liquidtight; and CSA Certified watertight.Available with DURA-PLATE® Finish. UL File No. E-23018CSA File No. 2884
A-109
United StatesTel: 901.252.8000
800.816.7809Fax: 901.252.1354
Technical ServicesTel: 888.862.3289
www.tnb.com
For wire mesh grips refer to page A-114.
Liquidtight Flexible Metal Conduit Fittings
Straight Liquidtight Fittings — HTCAT. CONDUIT DIMENSIONSNO. SIZE A B C
52® Series High-Temperature Flexible Metal Liquidtight FittingsWhere liquidtight flexible metal fittings are required in high-temperature environments up to 150° C:
• Fitting’s body, gland, locknut andground cone shall be constructedfrom steel or malleable iron, electro-zinc plated and chromate coated forcorrosion protection
• Fitting’s sealing ring and throatinsulator will be molded from high-temperature nylon, suitable fortemperatures up to 150° C and aminimum UL flammability rating of UL94-V2
• The fitting shall be constructed toaccept high temperature flexiblemetal liquidtight conduit rated to150° C
• The fitting shall have a plastic throatinsulator to protect conductors
• The fitting shall have a steel groundcone to:
— provide high quality ground contact
— single helical thread for easy installation into conduit
— rolled over edge to protect conductors
• The fitting shall have a plasticsealing ring to:
— grip and seal at leading and trailing edge(double bevel up to 2") of conduit jacket
— provide a watertight/oiltight seal
• The fittings shall be capable toterminate the conduit in either a threaded or threadless opening
• For applications where terminationinto a threaded opening is required,the fitting shall have external taperedNPT threads
• Fittings shall conform to UL 514B
• Accepted Manufacturers: Thomas &Betts — 5331-HT straight series,5341-HT 45° series, 5351-HT 90°series; 5262 sealing ring series
ATX Flexible Liquidtight ConduitCONDUIT LENGTH INSIDE BEND
T&B HT-SeriesLiquidtight Fittingsare available straight,45° and 90°.
A-110
United StatesTel: 901.252.8000
800.816.7809Fax: 901.252.1354
Technical ServicesTel: 888.862.3289
www.tnb.com
Liquidtight Flexible Metal Conduit Fittings
A-111
United StatesTel: 901.252.8000
800.816.7809Fax: 901.252.1354
Technical ServicesTel: 888.862.3289
www.tnb.com
Designed to resist corrosion.LTA Flexible Aluminum ConduitUse T&B LTA Flexible Aluminum Conduit with T&B Aluminum LiquidtightFittings in corrosive environments or where weight is a major consideration— such as oil platforms, saltwater applications, pulp and paper, refineries,wastewater and food processing.
• Construction: Utilizes the flexibility of a lightweight aluminum core, coupled withthe advantage of a PVC jacket that is virtually unaffected by sunlight, acid andoil. WEEE and RoHS compliant
• Application: Used in situations where concerns of excessive weight andcorrosion exist
High-quality, corrosion-resistant,liquidtight termination for LTAflexible aluminum conduit.52® Series Liquidtight Aluminum Connectors — Straight and 90˚
LiquidtightAluminumFitting —Straight
Liquidtight Flexible Metal Conduit Fittings
A-112
United StatesTel: 901.252.8000
800.816.7809Fax: 901.252.1354
Technical ServicesTel: 888.862.3289
www.tnb.com
A
B
A
CB
CONDUIT STD.CAT. SIZE DIMENSIONS (IN.) PKG. NO. (IN.) A B C QTY.
Stainless Steel High-Temperature Liquidtight Conduit Connectors — 150˚ C Max.
Blue is a trademark color of Thomas & Betts.
• Ideal for industrial MRO and OEMapplications in food and beverage,pharmaceutical, petrochemical,wastewater, salt water and othercorrosive environments
• Connects metallic-cored liquidtightconduit to a box or enclosure
• Type 304 stainless steel body andgland-nut resist corrosion farbetter than other metallic fittings
• Stronger and more UV-resistant than non-metallic fittings
• Ground cones are available in 11⁄4", 11⁄2" and 2" sizes and are brass/nickel plated
• Available in straight, 45° and 90°angled configurations to fit conduitfrom 3⁄8" to 2"
• UL Listed Ratings: 3, 3R, 4, 4X
• Standard version (SST Series)rated for temperatures up to 105˚ C (221˚ F)
• Now available in a new high-temperature version (SSTHTSeries) for applications up to 150˚ C (302˚ F)
The strength of steel — with superiorcorrosion-resistance!
Stainless Steel Liquidtight Conduit Connectors
NEW!NEW!
Until now, there’s been no ideal conduit fitting solution for use in heavily corrosiveenvironments. Traditional metallic fittings corrode and require frequent replacement.Non-metallic fittings offer less strength, lower UV-resistance and don’t stand upwell in extreme temperatures. T&B® Stainless Steel Liquidtight Conduit Connectorsare constructed of 304 stainless steel to resist corrosion while offering high strength,high UV-resistance and high endurance. Choose among a full range of fittings instraight, 45°, and 90° angled configurations for 3⁄8" to 2" conduit sizes. Look forthe distinctive blue insulator and sealing ring for assurance of T&B quality.
Liquidtight Flexible Metal Conduit Fittings
A-113
United StatesTel: 901.252.8000
800.816.7809Fax: 901.252.1354
Technical ServicesTel: 888.862.3289
www.tnb.com
Sealing material resists oil, coolants and hydraulic fluidsas well as water!
Liquidtight Sealing Gasket
Provides a re-usable rain-, dust- and oil-tight seal for unused knockouts!
Liquidtight K.O. Plug
5262 Series Sealing Gasket
STD.CAT. CONDUIT DIMENSIONS (IN.) PKG. NO. SIZE A B QTY.
With SAFE-EDGE® ground cone and double bevel sealing ring (through 2").
B
A
C
Nylon Insulated 90° Angle CHASE® ConnectorsCAT. CONDUIT DIMENSIONS (IN.)NO. SIZE A B C
5371† 3⁄8" 11⁄32 11⁄2 3⁄16
5372† 1⁄2" 115⁄64 115⁄323⁄16
5373† 3⁄4" 131⁄64 17⁄8 9⁄32
5374† 1" 123⁄32 21⁄4 11⁄32
With SAFE-EDGE® ground cone and double bevel sealing ring.NOTE: UL Listed Liquidtight; & CSA certified watertight. Suitable for hazardous locations use in Class I, Div. 2; Class II, Div. 1and 2; Class III, Div. 1 and 2, where general purpose equipment is specifically permitted per NEC Section 500-2(a).†UL listed as grounding means under NEC 351-7.Malleable iron
Prevents severe conduit bends and pullout!
Steel or malleable iron with O-Ring Seal
Liquidtight Flexible Metal Conduit Fittings
Series 5331GR
External Bonding Liquidtight Flexible Metal Conduit ConnectorsApplication• Used where external bonding jumper
is required around liquidtight flexiblemetal conduit
• To positively bond conduit to box or enclosure
• Used where flexible raceway isinstalled in outdoor or indoors location where exposed to continuous or intermittent moisture
Features• Designed with provision to install
bonding jumper in several positions• Designed to accept mechanical
or compression lug• Ability to install quickly with low
assures ground contact with lowimpedance and high raceway holding power (A)
(2) Single helical thread on ground cone is easy to install without cross thread;accepts variations in raceway diametersand convolution pitch (B)
(3) Rolled over edge protects conductors (C)
• Sealing ring design has followingexclusive features:(1) Grips and seals at leading and trailing
edge — will not abrade raceway jacket (D)
(2) Provided with grooves on insidediameter for anti-sleeving (E)
(3) Shoulders on both ends for extra sealing (F)
(4) Symmetrical shape ensures foolproof assembly
• Can be disconnected and reuse• Watertight/oil tight installation at
box or enclosure termination isensured by:(1) External taper thread hub on 5331GR
series and use of sealing gasket 5262series (G)
(2) Taper tapped hole on 5271 series
• Suitable for use in Class I Division 2,Class II Division 1 & 2 and Class IIIDivision 1 & 2 Hazardous Locationsper NEC Article 500
• Suitable as a bonding means per UL 467 and NEC Article 351-9
• Conforms with JIC requirements
Standard Material52/53GR Series
Lugs: High conductivity copper (for copperconductor only)
Body, Gland, Locknut & Ground Cones: All steel ormalleable iron
Sealing Ring and Insulator: All thermoplastic
Sealing Gasket: Stainless Steel and Santoprene
Strap: Steel
52ALGR Series
Copper-free aluminum
Standard Finish52/53GR Series
All Electro Zinc Plated and Chromate Coatedexcept lugs
Lugs: Bright Dipped
52ALGR Series
Zinc plating with clear chromate ground cones
Range5331GR Series (straight connectors with malehub): 3⁄8" thru 6" conduit
5341GR Series (45°): 3⁄8" thru 4" conduit
5351GR Series (90°): 3⁄8" thru 4" conduit
5232ALGR Series: 3⁄8" thru 1" conduit
All hubs provided with taper pipe threads (NPT)
Listings/CompliancesUL File #E-23018
CSA
UL 467
UL 514B
CSA C22.2 No. 18
CSA22.2 No. 41
NEMA FB-1
NFPA 70
JIC EGP1
JIC EMP1
Federal Specification A-A-50552
Federal Standard H-28 (threads)
1 per C.E. Code, this method is not permissible. SleevingRaceway Jacket pulls off — exposing core and affectingliquidtight termination. Feature (E) on sealing ring helpsovercome this problem.
A-115
United StatesTel: 901.252.8000
800.816.7809Fax: 901.252.1354
Technical ServicesTel: 888.862.3289
www.tnb.com
Liquidtight Flexible Metal Conduit Fittings
A-116
United StatesTel: 901.252.8000
800.816.7809Fax: 901.252.1354
Technical ServicesTel: 888.862.3289
www.tnb.com
Ground Wire
Max. over Ribs
90º Angle Ground FittingsMalleable iron tapered hub threads.
** 3⁄8" conduit fittings have 1⁄2" trade size hub. With safe-edge ground cone (through 4") and double bevel sealing ring (through 2").
UL Listed liquidtight; and CSA Certified watertight. Suitable for hazardous locations use in Class I, Div. 2; Class II, Div. 1 and 2;Class III, Div. 1 and 2, where general purpose equipment is specifically permitted per NEC Section 500-2(a). Available withDURA-PLATE® Finish. UL File No. E 3060 CSA File No. 638*NOTE: 3⁄8"–1" fittings include Revolver® grounding device. For sizes 11⁄4" and up, fittings are supplied with a copper mechanical lug.
Liquidtight Flexible Metal Conduit Fittings
41 Series
(E)
(C)
Gland
Resilient Seal(A)
Body
Liquidtight Unionfor Threaded Hub
(B)Controlled Deformation
of Resilient Seal
CAT. CONDUITNO. SIZE A B
41-TB 1⁄2" 129⁄64" 1"42-TB 3⁄4" 115⁄16" 11⁄4"
Steel, zinc plated and chromated. Ideal for angle fittingswhere swing clearance is not available.
Application• To couple threaded end of a fitting or
a pipe to a tapped opening in a boxor enclosure where rotation of fittingor pipe is limited or restricted
Features• Design provides high quality bond
between fitting or pipe to the union
• Provided with resilient seal (A)
• Resilient seal subjected to controlleddeformation; positive seal andreusability are ensured (B)
• Unique design centralizes throatopenings of threaded hub and union (C)
• Provided with taper threaded hub for liquidtight assembly (D)
• Straight pipe threads on gland accepta straight or taper threaded hub onfitting or pipe to be coupled (E)
• Suitable for hazardous location useper NEC Article 501 Class I, Division2, Article 502 Class II, Division 1 & 2and Article III Division 1 & 2
Standard Material/FinishGland.......…Steel/Electro Zinc Chromate Coated
* All items shown on this page are suitable for use in hazardouslocation where general purpose equipment is specifically permitted bythe NEC; Class I Div. 2, Class II, Div. 1 & 2; Class III, Div. 1 & 2, NEC501-4(b); 502-4(a)(b); 503-3(a)(b).
U.L. File No. E 23018. CSA File No. 2884
A-117
United StatesTel: 901.252.8000
800.816.7809Fax: 901.252.1354
Technical ServicesTel: 888.862.3289
www.tnb.com
(D)
Liquidtight Flexible Metal Conduit Fittings
CAT. FLEXIBLE METRIC A B CNO. CONDUIT SIZE PG THREAD MM MM MM
Nylon insulated straight connectors7330 1⁄4" 9 36 21 127360 5⁄16" 9 36 26 127361 3⁄8"† 11 40 29 147362 3⁄8"† 13.5 40 29 147363 11⁄2"† 16 41 35 147364 3⁄4"† 21 43 42 147365 1"† 29 56 47 197366 11⁄4"† 36 67 58 217367 11⁄2" 42 72 69 217368 2" 48 81 83 21*All items shown on this page are suitable for use in hazardous location where generalpurpose equipment is specifically permitted by the NEC; Class I Div. 2, Class II, Div. 1 & 2;Class III, Div. 1 & 2, NEC 501-4(b); 502-4(a)(b); 503-3(a)(b).†UL Listed as grounding means under NEC 351-7.UL Listed liquidtight. CSA Certified watertight.UL File No. E-23018 CSA File No. 2884
CAT. FLEXIBLE METRIC A B CNO. CONDUIT SIZE PG THREAD MM MM MM
All items shown on this page are suitable for use in hazardous location where generalpurpose equipment is specifically permitted by the NEC; Class I Div. 2; Class II, Div. 1 & 2;Class III, Div. 1 & 2, NEC 501-4(b); 502-4(a)(b); 503-3(a)(b).
Liquidtight Flexible Metal Conduit Fittings
A-119
United StatesTel: 901.252.8000
800.816.7809Fax: 901.252.1354
Technical ServicesTel: 888.862.3289
www.tnb.com
Provides a positive seal against water, oil and dust!
Steel Liquidtight Connectors for Type A Non-Metallic Flexible Conduit• Steel or malleable iron construction with nylon-insulated throat
• Santoprene® sealing gasket with Type 316 stainless steel retaining ring
• NPT hub threads seal in female threads
• Offers high mechanical pull-out strength
• Supplied with sealing ring and steel locknut
• Available in straight, 45º and 90º in hub sizes from 3⁄8" to 2" Straight Steel Liquidtight Connectors for Type A Conduit
CAT. CONDUIT DIMENSIONS (IN.)NO. SIZE HUB THREAD A B
Application• To provide a liquidtight, dust-tight connection between
flexible, non-metallic conduit and a box or an enclosure
Features• Serrated design provides high mechanical pull-out strength
• Unique component parts (body/ gland) design ensurespositive seal between conduit and connector
• Tapered thread hub and furnished Neoprene sealing O-ringprovide a liquidtight, dust-tight seal to a box or enclosure
• Smooth insulated body throughout for maximum dielectric strength
• Captive O-ring and reduced number of parts saveinstallation time
• High-strength thermoplastic construction — even tougherthan the raceway itself!
• Chemical-resistant — ideal for corrosive environments
• Non-burning, non-dripping thermoplastic material
Designed for Type A all-plastic raceways used in dynamic machine tool applications.
Liquidtight Flexible Metal Conduit Fittings
STD. PKG.CAT. NO. SIZE QTY.
Type A Flexible, Non-Metallic ConduitTYPEA38-250 3⁄8" 250 ft.TYPEA50-200 1⁄2" 200 ft.TYPEA75-175 3⁄4" 175 ft.TYPEA100-100 1" 100 ft.TYPEA125-100 11⁄4" 100 ft.TYPEA150-50 11⁄2" 50 ft.TYPEA200-50 2" 50 ft.
Ideally suited for continuous flexing applications or vibration.
Type A Non-Metallic Flexible Conduit
• No metal core to fatigue from flexing or vibration
• Smooth, seamless inner core of flexible PVC that is bondedto a covering of flexible PVC. Between these layers is a woven nylon mesh molded for reinforcement
• Available in sizes from 3⁄8" to 2"
• Working Temperatures: -20˚ C to 60˚ C
• Sunlight resistant
• UL Listed (conforms to UL Standard ANSI/UL 1660 Type A) UL file: E95745
• CSA Certified (conforms to CSA 22.2 No. 227.2 Type A)
• Meets NEC® Article 351, Part B (ANSI/NFPA-70) for flexible, liquidtight non-metallic conduit
Use on Shureflex™ fittings to achieveIP68 and IP69K ratings.Sealing Washers — NPT andISO Thread
“Easy unlock’’ quick removal without tools
It is extremely easy to remove the tube: Press the conduit andthe release ring against the bodyof the connector and then keepingthe release ring pressed, pull theconduit outwards, twisting it alittle. Both connector and conduitcan be reused, following theassembly instructions given.
Insert the conduitall the way intothe connector.
IP66 IP68 IP69K
Follow the process explainedfor IP66, but first insertingan O-ring on the first grooveof the conduit and a sealingwasher on the thread at thebase of the connector.
The best performance in only one piece!
In addition to the components shown in thiscatalog, the Shureflex™ system also providesfittings for special applications:
• PG threaded connectors
• 45º connectors
• Metal thread metric and PG connectors
• Sweep 90º connectors
• 90º flanged connectors
• Female threaded connectors
Use on Shureflex™ conduitto achieve IP68 and IP69Kratings.
O-Rings
• Combined use of O-ring on conduit andsealing washer on fitting provides IP68 andIP69K ratings
• Insert in first groove of Shureflex™ nylonconduit before inserting conduit into fitting
• Made of NBR70 elastomer
• Temperature rating of –30˚ C to 100˚ C(–22˚ F to 212˚ F)
Protection up to IP66 Protection up to IP69K
“Easy click’’ quick assembly
• Combined use of sealing washer on fitting and O-ring on conduit provides IP68 and IP69K ratings
• Place around thread of Shureflex™ fitting, betweenfitting and entry panel
• Made of deformable, asbestos-free material
• Temperature rating of –40˚ C to 200˚ C (–40˚ F to 392˚ F)
XTRA FLEX® System —Conduit, Tubing, Fittings for Non-Metallic Liquidtight Conduit
Specification Sheet — Bullet® Liquidtight Fittings or Liquidtight Flexible Non-Metallic Conduit and Tubing
Box orEnclosure
Wall
Conduitor Tubing
ApplicationA series of nonmetallic connectors designed to provide a liquidtight seal when terminatingliquidtight nonmetallic conduit (UL Type B) or liquidtight nonmetallic tubing to a box orenclosure with knockout opening or a threaded hub.
Plastic Bullet® Liquidtight Fittings Features• Connector assembles to conduit
without disassembly and is designedto be installed with a positiveinstallation criteria gland bottoms on body shoulder
• Rugged low profile non-metallic body and gland construction (1); theconnector is equipped with a steellocknut to firmly secure connector to box or an enclosure and a sealing O-Ring
• Captivated sealing O-Ring (2) withpredetermined compression for areliable seal at enclosure
• Connector ferrule designed to acceptvariations in conduit inside diameterand is tolerant of field conduit cuts (3)
• The profile of ferrule is designed toreduce friction between conduit I.D.and ferrule, (4) enabling conduit toseat properly for an effective seal
• Outer surface of the clamping fingersprovided with friction reducing ridges(5) for ease of installation; the innersurface is designed with conduitbiting teeth to enhance clamping and sealing action (6)
• Performance of connectors tested to simulate adverse installationconditions
• Provides a double sealing action (7)
• Elongated gland nut profile (8) de signed to provide additional strain relief for 90° pull and an easy hand grip.
• Performance of connector unaffectedby exposure to detergents, cleanersand sanitizers commonly encounteredin food processing plants and typicalindustrial environment; alsounaffected by cutting fluids, wiringpulling compounds and marineenvironment. The connector meetsindustry standards for cold impactand simulated hammer blow.
Standard Material/Finish• Body Gland — Weather stabilized
thermoplastic (black)
• O-Ring — Neoprene (black)
• Locknut — Steel/electro zinc plated
• Material Temperature Rating —thermoplastic -40° C to 105° C
• Material Flammability Rating: UL 94-V2
Listings/Compliances
• UL (File# E23018)
• CSA (File# LR52391)
• CSA 22.2 #227.2 & CSA 22.2 #227.3
• ANSI/U.L.514B-1988
• Watertight requirements of NEMAType 4 and NEMA Type 6 enclosures
• Federal Standard H28 (NPT threads)
• Suitable for hazardous locations —Class I Div. 2; Class II Div. 1 & 2;Groups E,F, & G; Class III per N.E.C.;Article 501-4, 502-4 and 503-3
• NEMA 6P
Suggested Specification:
Where liquidtight flexible non-metallic conduit(UL Type B) or liquidtight flexible non-metallictubing is terminated to a box or enclosure, thenon-metallic connectors used shall be able to be installed without disassembly and provide a positive installation criteria. In the installedcondition, the connector must provide a sealmeeting watertight requirements of NEMA Type4 and Type 6 enclosures. The performance ofconnectors shall be unaffected by exposure todetergents, sanitizers, cutting fluids, wire pullingcompounds and oil base industrial paints. Theconnector must also be capable of withstandingMarine environment and cold impact simulatinga hammer blow. Installed connectors shall be ofthe elongated gland type as manufactured byThomas & Betts LT38P series.
A-126
United StatesTel: 901.252.8000
800.816.7809Fax: 901.252.1354
Technical ServicesTel: 888.862.3289
www.tnb.com
XTRA FLEX® System —Conduit, Tubing, Fittings for Non-Metallic Liquidtight Conduit
Plastic Bullet® Liquidtight Fittings for T&B LTC Non-MetallicLiquidtight Conduit Type B and T&B EFC Flexible Tubing
This engineering breakthrough meets thedemand for a tough, reusable, non-metallicliquidtight fitting for use with XTRA FLEX®
Type B conduit or flexible tubing. The BULLET®
non-metallic fitting provides a reliable liquidtightseal that combines high pullout resistance andease of installation.
Engineered to meet your needs.The BULLET® non-metallic fitting meets yourperformance requirements when terminatingType B liquidtight non-metallic conduit or flexiblenon-metallic tubing to a box or enclosure withknockout opening or threaded hub. Fittings meetthe watertight requirements for NEMA Type 4and Type 6 enclosures and conform to UL514Band CSA No. 22.2 #227.2 specifications.
Ease of installation.Installations can be performed quickly and easilybecause BULLET® liquidtight fittings can beinstalled without disassembly. BULLET® non-metallic fittings are resistant to numerouscaustics and solvents.
The BULLET® fitting is economical because it canbe used over and over again without sacrificingthe quality of the original seal. When used withthe XTRA FLEX® raceway system, you can meetmost machine or industrial requirements whereliquidtight protection is needed.
Corrosion-resistant. Built to take it.The BULLET® liquidtight fitting is manufacturedfrom weather-resistant thermoplastic materialsand is suitable for indoor or outdoor corrosiveenvironments. The BULLET® fitting is resistant todetergents, cleaners, oils, sanitizers, paints,cutting fluids and wire pulling compounds —just about any liquid usually found in industrial,plant or marine environments. It also surpassesindustry standards for cold impact and simulatedhammer blows.
C
B*
A ETHREAD
D
FIGURE 1(STRAIGHT)
C
F*
B*
A ETHREAD
D
FIGURE 2(45 DEGREE)
C
F*
B*
A ETHREAD
D
FIGURE 3(90 DEGREE)
C ±.015 (0.40) MIN. ETRADE A ±.015 ACROSS THROAT THREAD F*SIZE (.040) *B ±.035 (0.90) CORNERS DIA. D NPT (IN.) (MM)
Where liquidtight flexible non-metallic conduit (UL Type B) or liquidtight flexible non-metallic tubing isterminated to a box or enclosure, the metallic connectors used shall be able to be installed withoutdisassembly and provide a positive installation criteria. In the installed condition, the connector mustprovide a seal, meeting watertight requirements of NEMA Type 4 and Type 6 enclosures with conduit andNEMA Type 4 enclosures with tubing. Installed connectors shall be as manufactured by Thomas & BettsLT38M series.
Material: Body/Gland — Steel/MI
Insert — Nylon
NPT Thread
Figure 3
Figure 2
Figure 1
Figure 2
Figure 3
NPT Thread
A
B
C
A
B
C
AB
C
D
A-129
United StatesTel: 901.252.8000
800.816.7809Fax: 901.252.1354
Technical ServicesTel: 888.862.3289
www.tnb.com
XTRA FLEX® System —Conduit, Tubing, Fittings for Non-Metallic Liquidtight Conduit Material — PVC
ISO Metric Bullet® Liquidtight Fitting Non-MetallicCAT. ANGLE CONDUIT KNOCKOUT UNIT STANDARD UPCNO. OF FITTING SIZE SIZE PACKAGE PACKAGE NUMBER
*Testing: UL and CSA listed; NEMA 4, 6, 6P; IP 67 when used with LTC conduit or EFC tubing with installed T&B Bulletliquidtight fitting.
Thomas & Betts introduces the ISO Metric Bullet® liquidtight fittings for use with the 3⁄8", 1⁄2" and 3⁄4" XTRA FLEX® EFC and LTC non-metallic liquidtight conduit series.
The T&B Bullet® liquidtight fitting and EFC non-metallic conduit are suited for OEM applications as in the machine tool industry where environments include
continuous motion, vibration and exposure to moisture, oil, dirt and dust.
The T&B Bullet® liquidtight fitting and LTC non-metallic conduit are also suitable forconstruction applications where ISO metric threading and liquidtight systems are installed.
The XTRA FLEX® system offers a lightweight, liquidtight flexible conduit solution for industrialapplications. The XTRA FLEX® system enables fast, easy installation and high performance in
demanding industrial applications.
When you have a conduit application in a liquidtight environment, it’s time to load up the T&B Bullet®.
A-130
United StatesTel: 901.252.8000
800.816.7809Fax: 901.252.1354
Technical ServicesTel: 888.862.3289
www.tnb.com
XTRA FLEX® System —Conduit, Tubing, Fittings for Non-Metallic Liquidtight Conduit Material — PVC
CONDUIT I.D. (IN.) O.D. (IN.)CAT. NO. SIZE MIN. MAX. MIN. MAX.
• Good tensile strength provides excellent pullout protection
• Smooth inner diameter allows easy wire pulling
• Broad operating temperature range: 18° C to +60° C (-2° F to +140° F).
• Flammability Rating VW-1 (Vertical Wire) UL224
Recommended industrial applications• Protection of fiber optic cable
• Installation of instrumentation and control cable
• Indoor/outdoor lighting
• Packaging equipment
• Marine and shipboard wiring
• Flexing component wiring protection on robots, graphic arts equipment, etc.
* Not CSA Certified.Underwriters RecognizedUL File No. 96548
CSA File No. 067241See technical data next page.Use with Bullet® Liquidtight Fittings.
AVAILABLE COLORSCAT. NO. COLOR OFLTC – CONDUIT
W/O SUFFIX Black-1 Orange-2 Blue
A-131
United StatesTel: 901.252.8000
800.816.7809Fax: 901.252.1354
Technical ServicesTel: 888.862.3289
www.tnb.com
XTRA FLEX® System —Conduit, Tubing, Fittings for Non-Metallic Liquidtight Conduit Material — PVC
XTRA FLEX® Liquidtight Conduit/Reel LengthsCAT. NO. SIZE DESCRIPTION MIN. I.D. MAX. I.D MIN. O.D MAX. O.D. REEL LENGTH MIN. ORDER
LTC038GY-500 3⁄8" Gray Type B LT Conduit .484" .504" .690" .710" 500 ft. 1,500LTC050GY-500 1⁄2" Gray Type B LT Conduit .622" .642" .820" .840" 500 ft. 1,500LTC050-500 1⁄2" Black Type B LT Conduit .622" .642" .820" .840" 500 ft. StockLTC050GY-1000 1⁄2" Gray Type B LT Conduit .622" .642" .820" .840" 1,000 ft. 2,000LTC100GY-500 1" Gray Type B LT Conduit 1.041" 1.066" 1.290" 1.315" 500 ft. 1,500LTC100-500 1" Black Type B LT Conduit 1.041" 1.066" 1.290" 1.315" 500 ft. 1,500
UL Listed, UL File No. 95745
CSA Certified, CSA File No. LL 80349
Now available in reels.
XTRA FLEX® ConduitThe XTRA FLEX® system offers a lightweight, liquidtight flexible conduitsolution for demanding applications. The XTRA FLEX® system ensures fast, easy installations and long-lasting, high performance in a varietyof environments.
Now, XTRA FLEX® Conduit is available on reels. Large users can save spaceand reduce waste, while taking advantage of the convenience of stockingbulk in lengths. Utilizing our new coupling design to connect 100-ft. lengths,Thomas & Betts now offers reel lengths up to 1,000 feet.
• Fast installation — even in tight, cramped spaces
• Smooth inner diameter enables easy wire pulling
• Smooth outer jacket — approved for outdoor use, sunlight resistant and oil resistant
• Tested to CSA and UL requirements
• Lightweight and liquidtight
• Marked at 1-foot intervals for fast, easy measuring
AVAILABLE COLORSLTC – COLOR OF COLOR OFCAT. NO. CONDUIT MARKING
W/O SUFFIX Black Orange-1 Orange Black-2 Blue Black
Rated at 600V
XTRA FLEX® Type B suitable for use inhazardous location (for LTC Series only)where general purpose equipment isspecifically permitted by the NEC; Class IDiv. 2; Class II, Div. 1 & 2; Class III, Div. 1 & 2, NEC 501-4(b); 502-4(a)(b); 503-3(a)(b).
NOTE: These chemical resistance ratings are based upon information supplied by the raw material manufacturers. It is intended as a general guideline only. To determine specific suitability,samples should be tested by user under actual conditions. Operating Condition: 70° F.
A-134
United StatesTel: 901.252.8000
800.816.7809Fax: 901.252.1354
Technical ServicesTel: 888.862.3289
www.tnb.com
Flexible Cord and Cable Fittings
Liquidtight Flexible Cord and Power Cable FittingsWe also offer liquidtight fittings designed to handle the unique connection demands of flexible cords andpower cable applications, where exceptional mechanical strain relief is needed in addition to a dependableseal against dust, oil and other liquids.
The design of our flexible cord and power cable fittings is ideal for installations such as robot manufacturers,packaging equipment, machine tool building and other industrial OEM and MRO applications.
Flexible Cord ConnectorsThe Ranger® Series Cord Connector FittingsOur Ranger® Liquidtight fittings are the only connectors able to take a .250 inch cable range.
These unique connectors feature:• Connectors that take twice the cable range of ordinary strain relief connectors
• Smaller overall size that makes it easy to fit into tight spaces
• Gland nut design that restricts cable bending
• Choice of aluminum, steel, stainless steel and non-metallic materials
• Straight, 45° and 90° designs
The advantages these fittings offer include:• Neoprene bushing to make liquidtight installations by applying pressure
against the cable for the full length of the bushing
• CSA certified watertight
• UL listed for liquidtight strain relief and as an outlet bushing
• Metal and plastic assemblies capable of accepting a wide range of cords
• Black Beauty® non-metallic cord connector offers the convenience of tool-freeinstallation, with a segmented chuck for high mechanical pullout performance,and neoprene bushings for a secure, liquidtight installation.
A-135
United StatesTel: 901.252.8000
800.816.7809Fax: 901.252.1354
Technical ServicesTel: 888.862.3289
www.tnb.com
Whatever the application. Whatever the size.Thomas & Betts is your connection to tough,versatile cord and cable fittings.Thomas & Betts offers a complete line of rugged, reliable cord and cable fittings. All fittings areproduced to the highest standards, combining innovative design and precision manufacturing methodsto provide the products you need for your specific applications. Combining proven performance,installation advantages and availability of ranges, T&B is also your connection to lower installed costsfor the life of your cord and cable requirements.
Use this guide to help you specify the fitting you need for your cord and cable requirements.
Cord and Cable RequirementsCORD AND CABLE TYPE T&B FITTING
S, SO, SV, ST, STD, SJ, Ranger® 2920NM# Series, 2920# SeriesSJO, SJT, SJTO, SVO Liquidtight Strain Relief 2500# SeriesS, SO, SV, ST, STD, SJ, SJO, SJT, SJTO, SVO Wire Mesh Grips WMG-PC Series for Portable Cord
Flexible Cord and Cable Fittings
Considerations for Selection• Selection of the proper device or fitting involves consideration of the type of cable
to be installed and the environment that will surround the cable installation.
• A proper matching of the cable and its fitting is necessary to prevent physicaldamage to the cable when installed.
• NEMA Applications: Fittings used in a trade size knockout requiring a NEMA 3R, 4, 6 or 13 listing require a 5262 Series sealing ring.
Cord and Cable DescriptionsType SJ, tradename is Junior Hard Service Cord. The outer covering is Thermoset and it is a pendant or portable cord used in damp locations for hard usage.
Type SJO, tradename is Junior Hard Service Cord. The outer covering is oil-resistant Thermoset.
Type SJT, tradename is Junior Hard Service Cord. The outer covering is Thermoplastic.
Type SJTO, tradename is Junior Hard Service Cord. The outer covering is oil resistant Thermoplastic.
Type SO, tradename is Hard Service Cord. The outer covering is oil-resistant Thermoset and it is a pendant or portable cord used in damp locations for extra hard usage.
Suggested Specifications for Flexible Cord and Cable Fittings• Flexible cord or cable and associated fittings
shall be suitable for conditions of use andlocation and approved for the purpose bya nationally recognized testing laboratory,inspection agency or product evaluationorganization
• Flexible cord or cable shall be so connectedto the device or fitting that tension will notbe transmitted to joints or terminal screws.Sufficient slack shall be provided to avoid
sharp flexing and straining. Cord or cableshall be installed in such a manner thatliquid will tend to run off the surface insteadof draining towards the fitting
• Where flexible cord or cable exposed tointermittent or constant moisture andsubjected to mechanical strain is terminatedinto a threaded or threadless opening,terminating fittings shall be of watertightstrain relief type such as Thomas & Betts
series 2920, 2920AL, 2920NM, 2520, 2631or 2672. Fittings shall be equipped witha beveled moisture resistant/oil resistantsynthetic rubber bushing
• Where space is limited inside theenclosure, a female hub type fitting suchas Thomas & Betts series 2631 shall befurnished. A captivated resilient sealingO-Ring shall be included to positivelyprotect against damage from overtorquing
A-136
United StatesTel: 901.252.8000
800.816.7809Fax: 901.252.1354
Technical ServicesTel: 888.862.3289
www.tnb.com
Flexible Cord and Cable Fittings
2920 Ranger® Series 2920AL Ranger® Series
Ranger® Series of Liquidtight Flexible Cord and Cable ConnectorsStandard Material
Gland, Body . . . . .Steel/Malleable Iron/Zinc Die Cast
2900 and 4900 Ranger® Series . . .0.250" cable range
Cord/Cable Type . . . . . . . . . .S, SO, SV, ST, STO, SJ, SJO, SJT, SJTO, SVO & SVT
Listings/Compliances
UL File No. E-13938
CSA LR-589, LR-4484
UL 514
CSA. 22.2 No. 18
ANSI C33.84, NFPA 70-1978 (ANSI)
SVO, SV, SVT SJ, SJO, SJT, SJTO S, SO, ST, STOCAT. NO SIZE MIN. MAX. #18 #18 #16 #14 #18 #16 #14 #12 #10 #8 #62 Conductor2920 1⁄2" 0.125 0.375 X X X X2921 1⁄2" 0.310 0.560 X X X X X2922 1⁄2" 0.500 0.750 X X X X X X2930 3⁄4" 0.125 0.375 X X X X2931 3⁄4" 0.310 0.560 X X X X X2932 3⁄4" 0.500 0.750 X X X X X X2940 1" 0.310 0.560 X X X X X2941 1" 0.500 0.750 X X X X X X2942 1" 0.700 0.950 X X X3 Conductor2920 1⁄2" 0.125 0.375 X X X2921 1⁄2" 0.310 0.560 X X X X X2922 1⁄2" 0.500 0.750 X X X2930 3⁄4" 0.125 0.375 X X X2931 3⁄4" 0.310 0.560 X X X X X2932 3⁄4" 0.500 0.750 X X X2940 1" 0.310 0.560 X X X X2941 1" 0.500 0.750 X X X X2942 1" 0.700 0.950 X X
4 Conductor2920 1⁄2" 0.125 0.375 X2921 1⁄2" 0.310 0.560 X X X X X2922 1⁄2" 0.500 0.750 X X2930 3⁄4" 0.125 0.375 X2931 3⁄4" 0.310 0.560 X X X X X2932 3⁄4" 0.500 0.750 X X2940 1" 0.310 0.560 X X X X X2941 1" 0.500 0.750 X X2942 1" 0.700 0.950 X X
2516 Series
A-137
United StatesTel: 901.252.8000
800.816.7809Fax: 901.252.1354
Technical ServicesTel: 888.862.3289
www.tnb.com
2920SST Ranger® Series
Application• A liquidtight connector to connect flexible cord or cable
to an enclosure and provide adequate strain relief
Features• Liquidtight connection with enclosure is ensured by:
(A)Taper threaded hub on 2520 series for female hubapplication
(B)Using sealing ring series 5262 with 2520 seriesfor knockout application
(C)Captivated sealing O-Ring on 2631 series
(D)Neoprene bushing makes liquidtight installation; appliespressure against cable the full length of bushing
(E)Thermoplastic or stainless steel retaining ring(1) Will not abrade cord/cable jacket(2) Reduces installing torque effort
• UL Listed liquidtight, strain relief and as an outlet bushing;CSA certified watertight
Flexible Cord and Cable Fittings
HUB THROAT DIMENSIONS (IN.)CAT. NO. SIZE DIA. CORD RANGE A B C
All items shown on this page are suitable for use in hazardous locations where generalpurpose equipment is specifically permitted by the NEC. NEC 501-4(b).
U.L. File No. E-13938 CSA File No. 52391
HUB THROAT DIMENSIONS (IN.)CAT. NO. SIZE DIA. CORD RANGE A B C
4920 1⁄2" 37⁄64 .125-.375 11⁄8 15⁄1647⁄64
4921 1⁄2" 37⁄64 .310-.560 11⁄8 15⁄1647⁄64
4922 1⁄2" 37⁄64 .500-.750 13⁄8 17⁄1647⁄64
4930 3⁄4" 25⁄32 .125-.375 13⁄8 17⁄165⁄8
4931 3⁄4" 25⁄32 .310-.560 13⁄8 17⁄165⁄8
4932 3⁄4" 25⁄32 .500-.750 13⁄8 17⁄165⁄8
C
B
A
C A
B
C
B
A
The Ranger® Series of Steel Liquidtight Cord Connectors
Application• Provide means for
passing a cord cable into an enclosure, through a bulkhead or into a rigid conduit
• Form a mechanical grip and water and/or oil-resistant seal for cord
• Form a non-slip connection or termination for flexiblecord
Cord & Cable Type• S, SO, SV, ST, STD, SJ,
SJO, SJT, SJTO, SVD
Features• Extended range with
superior strain relief
• Reduced overall size, fits into tighter spaces
• Gland nut designed to restrict cable bending
MaterialsBody: Steel-2920 series,
Malleable Iron-4920 & 4960 series
Gland Nut, Grip: Steel-all seriesBushing: Rubber
Environment Classification• Ordinary locations
• Wet or dry locations
• Fittings used in a trade sizeknockout requiring a NEMA3R, 4, 6 or 13 listing require a 5262 Series sealing ring
The Ranger® Series Steel Liquidtight Connector takes twice the cable range of most ordinary strain relief connectors. T&B’s Ranger Connectors enable you to reduce your inventory and save time with one connector that can do the work of two.
HUB THROAT DIMENSIONS (IN.)CAT. NO. SIZE DIA. CORD RANGE A B C
The Ranger® Series of Non-Metallic Liquidtight Cord ConnectorsApplication• Provide means for passing a cord
into an enclosure or through abulkhead or into a rigid conduit
• Form a mechanical grip and waterand/or oil-resistant seal for cord
• Form a nonslip connection ortermination for flexible cord, cable (armored or unarmored)
Cord & Cable Type• S, SO, SV, ST, STD, SJ, SJO,
SJT, SJTO, SVD
Features• Extended range with
superior strain relief
• Reduced overall size, fits into tighter spaces
• Gland nut designed to restrict cable bending
MaterialsWeather stabilized nylon, temperaturerated -34° C to 105° C
Bushing: Rubber
Environment Classification• Ordinary locations
• Wet or dry locations
• Fittings used in a trade size knockoutrequiring a NEMA 3R, 4, 6 or 13 listingrequire a 5262 Series sealing ring
RangeCord Range: Straight —.125" to .950"90° —.125" to .750"
Hub Size Range: Straight — 1⁄2" to 1"90° — 1⁄2" to 3⁄4"
Listings/CompliancesUL Type 6 and 4X
The Ranger® Series Non-Metallic Liquidtight CordConnector takes twice the cable range of mostordinary strain relief connectors. T&B’s RangerConnectors enable you to reduce your inventoryand save time with one connector that can do the work of two. The sturdy nylon material addscorrosion resistance to your installation.
TRADE OR THROAT DIMENSIONS (IN.)CAT. NO. HUB SIZE DIA. CORD RANGE A B C
Type 304 stainless construction for your harshest environments!
The Ranger® Series of Stainless Steel Liquidtight Cord ConnectorsUntil now, there’s been no ideal solution for liquidtight connections ofportable cord to a box or enclosure in corrosive environments. Steelconnectors rust, and non-metallic connectors can’t withstand hightemperatures or ultraviolet exposure.
In response to customer demand, Thomas & Betts has developed the latest addition to its high-performance line of Ranger® Cord Connectors.Made of Type 304 stainless steel, Ranger® Stainless Steel Liquidtight CordConnectors stand up to highly corrosive environments — such aswashdown areas in food and beverage or pharmaceutical processing — as well as high temperatures and UV exposure.
Application• Provide means for passing a cord cable into an enclosure,
through a bulkhead or into a rigid conduit
• Form a mechanical grip and water and/or oil-resistant sealfor cord
• Form a non-slip connection or termination for flexible cord
13⁄16 2 25 18.20* It may be necessary to remove sufficient outer covering of cable to permit conductors to pass through connector body.
All items shown on this page are suitable for use in hazardous locations where general purpose equipment is specifically permitted by the NEC. NEC 501-4(b).
UL File No. E-13938 CSA File No. 52391
A-141
United StatesTel: 901.252.8000
800.816.7809Fax: 901.252.1354
Technical ServicesTel: 888.862.3289
www.tnb.com
For wire mesh grips refer to page A-147.
A
C
B
D
A
C
B
Application• A liquidtight connector to connect
flexible cord to an enclosure andprovide adequate strain relief
• Form a mechanical grip and water and liquidtight seal
• Form a non-slip connection or termination for flexible cord
• Designed to accept a wide range ofcables, offering nine fittings that covercord ranges from .125" through .950"
• Slotted design gland nut toaccommodate securing in tight spaces
• Installer can simply use screwdriver to get into the hard-to-reach area and secure the gland nut
• Marked with cable ranges and conduithub sizes
Material• Body: Copper-free Aluminum
Gland Nut, Grip: Copper-free Aluminum — all series Bushing: Thermoplastic RubberGrip Ring: Nylon
Environment Classification• Ordinary locations
• Wet or dry locations
• Temperature Range: -20º C to 105º C (-4º F to 221º F)
Range• Cord Range: .125" to .950
• Hub Size Range: 1⁄2" to 1"
The Ranger® Series of Aluminum Liquidtight Cord Connectors
NEW!NEW!
Flexible Cord and Cable Fittings
T&B Liquidtight Strain Relief Cord Connectors
CABLE SIZE THROAT BUSHING GLAND-NUT RETAINER BODYCAT. RANGE HUB DIA. DIMENSIONS (IN.) PART MODEL MODEL MODELNO. MIN.-MAX. SIZE (MIN.) FIG. A B C NO. NO. NO. NO.
The T&B Steel Liquidtight Strain Relief CordConnector is suited for most general control and power cable applications. This seriesfeatures sturdy neoprene bushings and tapered hub threads.
Application• Provide means for passing a cord cable
(armored or unarmored) into an enclosure,through a bulkhead or into a rigid conduit
• Form a mechanical grip and water- and/oroil-resistant seal for cord and unarmored or jacketed armored round cables
• Form a non-slip connection or termination forflexible cord, cable (armored or unarmored)
In many applications you have only room for one fitting but you need to run two cables forexample, proximity switches. Now you can provide strain relief and liquidtight protection withT&B’s new multi-hole liquidtight strain relief connectors. With the ever-increasing number ofsignal cables, now you have a solution to the problem of how to strain relieve multiple cables in one fitting.
Suitable for hazardous locations use in Class I, Div. 2; Class II, Div. 1 and 2; Class III, Div. 1and 2, where general purpose equipment is specifically permitted per NEC Section 500-2(a).
Complete with O-Ring seal and nylon insulated throat and neoprene bushing.
UL Listed as liquidtight strain relief, and outlet bushing.CSA certified watertight.
Temperature Rating: 105° C UL File No. E 13938
CSA File No. 589. CHASE® Liquidtight Cord Connectors are ideal for installation where space is limited inside the enclosure.
Black Beauty® Non-Metallic Liquidtight Strain Relief Connector — Straight
*Remove sufficient outer covering of cable to permitconductors to pass thru connector body.
UL File No. E 13938CSA File No. 52391
All items shown on this page are suitable for use in hazardouslocation where general purpose equipment is specificallypermitted by the NEC. Class I, Div. 2. Class II, Div. 1 & 2. Class III, Div. 1 & 2. NEC 501-4(b), 502-4(a)(b), 503-3(a)(b).
CAT. TRADE OR THROAT DIMENSIONS (IN.)NO. HUB SIZE DIAM. (IN.) CORD RANGE (IN.) A B C
Black Beauty® Non-Metallic Liquidtight Strain Relief Connector — 90° Elbow
*Remove sufficient outer covering of cable to permitconductors to pass thru connector body. 90° angle, standard size body.
UL File No. E 13938
CSA File No. 52391
All items shown on this page are suitable for use inhazardous locations where general purpose equipment isspecifically permitted by the NEC. Class I, Div. 2. Class II,Div. 1 & 2. Class III, Div. 1 & 2. NEC 501-4(b), 502-4(a)(b),503-3(a)(b).
A-146
United StatesTel: 901.252.8000
800.816.7809Fax: 901.252.1354
Technical ServicesTel: 888.862.3289
www.tnb.com
2920 Series
2920AL Series
2516 Series
T&B Wire Mesh grips are ordered separately and fit with your existing inventory of Ranger®
connectors and liquidtight strain relief connectors. There’s no need to duplicate inventory.
The T&B WMG-PC Series Wire Mesh Grips for Portable Cord
Application• Provides high gripping strength for adequate cable support
and strain relief without damage to the cable sheath• Compression of a tapered neoprene bushing ensures
the watertight integrity of the fittings• To meet National Electrical Code or NEC requirements for electrical
installations in hazardous atmospheres, a sealing fitting may berequired in conjunction with the cable and cord fitting
Cord & Cable Type• S, SO, SV, ST, STD, SJ, SJO, SJT, SJTO, SVDFeatures• Prevents severe cord bends and pullouts• Used in aluminum and/or steel fittings
Materials• Wiremesh made of stainless steel.
Retaining rings made of aluminumEnvironment Classification• Ordinary locationsRange• .187 – 3.220
®
Flexible Cord and Cable Fittings
How to select proper wiremesh grip:1. Determine O.D. of portable cord, e.g., .200
2. Determine size of knockout or threaded hub, e.g. 1⁄2"
*Listed under UL file E13938, control #137B NPT and PG threaded Cable Glands are UL Listed, ISO/Metric Threaded Cable Glands are not UL Listed.
T&B Nylon Cable Glands have a sturdy cable sealingmechanism that results in superior strain relief. The compact size ensures quick and easy installationin cramped spaces. The non-metallic constructionprovides excellent corrosion, chemical and impactresistance. The glands have long threads andlocknuts are available.
• Halogen-free
• Flame-retardant UL 94V0
• Rated IP 68 5 BAR, suitable for NEMA 4 enclosures
• UL Listed*, CSA listed for certain ranges of cable
• Working temperatures -30º C (-86º F) to +80º C (176º F)
• Continuous, +150º C (276º F) Intermittent
• Meets VDE ratings
* Material not UV resistant.
Low-profile cable gland perfect for tight spots.
Sturdy Nylon 6 for strong, lightweight construction. Gray color shown, also available in black.
Non-Metallic Cable Glands
A-148
United StatesTel: 901.252.8000
800.816.7809Fax: 901.252.1354
Technical ServicesTel: 888.862.3289
www.tnb.com
Non-Metallic Cable and Cord Fittings
MIN. CABLE MAX CABLE USE T&B DIMENSIONS (IN.) STD. PKG.CAT. NO. SIZE RANGE RANGE LOCKNUT CAT. NO. COLOR A B QTY.
Thomas & Betts is pleased to announce the new non-metallic spiral cable/cordconnector. T&B spiral cable/cord connectors are ideal in environments wheremaximum protection is needed against conductor fatigue caused by flexing cables.
Non-Metallic Cable/Cord Fitting with Integral Strain-Relief
]
]
A
B
NEW!NEW!
Multi-Hole Cord Grip Connectors
TRADE NUMBER OF CABLE RANGE BODY LENGTH LENGTH THREADCAT. NO. SIZE OPENINGS MINIMUM MAXIMUM MINIMUM MAXIMUM PER 100 WEIGHT
Protection Class . . . . . . . . . . . . . . . . . IP 68, 5 Bar
Temperature Range . . . . . . . . . . . . . . . – 30° C to +80° C permanent(-86° F – +176° F)
Operating Temperature . . . . . . . . . . . . Up to +150° C (+276° F)continuous
Please contact your Thomas & Betts sales representative regarding our custom grommet offering.
• Ideal in limited space environments where multiple cables run into an enclosure
• Small cables such as instrumentation wires, proximity device wiring and signal cables can run safely into the enclosure
• Liquidtight, easy to assemble, provide good strain relief, offer a wide clamping range and are simple to use
Space and labor-saving cord fittings for panels.
A-149
United StatesTel: 901.252.8000
800.816.7809Fax: 901.252.1354
Technical ServicesTel: 888.862.3289
www.tnb.com
Service Entrance Cable Fittings
All service fittings shall be approved for the purpose by a nationallyrecognized testing laboratory, inspection agency or product evaluation organization.
Where service raceway consists of a rigid metal conduit, intermediatemetal conduit, electrical metallic tubing or where service entrancecable is used as service conductors, a suitable rain tight service head conforming to Federal Standard W-C-586 shall be provided.
Service raceway shall be securelyfastened in place to the supportingsurface at intervals as specified bythe Code using suitable straps andspacers; straps and spacers shallbe of malleable iron or steelconstruction, hot dipped galvanizedor electro zinc plated conforming to Canadian Standards AssociationStandard C22.2 No. 18 and asmanufactured by Thomas & Betts:series 1275 or 4175 straps andseries 1350 spacers; aluminumstraps or spacers such as series1275AL and series 1350AL maybe substituted when installed inenvironmental conditions that aremore than normally corrosive.
Grounding & Bonding
For grounding and bonding ofservice raceway, end of raceway or the terminating fitting shall beequipped with bonding locknutsand insulated metallic groundingand bonding bushing as required.
Bonding locknuts shall be ofhardened steel or malleable ironconstruction, electro zinc plated,and provided with hardenedbonding screws as manufacturedby Thomas & Betts, series 106bonding locknuts.
Insulated metallic grounding andbonding bushing shall be ofmalleable iron/steel construction,electro zinc plated and assembledwith an insulator listed or certifiedfor 150° C/302° F service asmanufactured by Thomas & Betts,series 3870.
Threaded Rigid Metal
Where threaded rigid metal serviceraceway enters the building, theraceway shall be equipped with a cast malleable iron/copper-freealuminum entrance ell suitablybushed with a burr-free end stop and taper tapped holes asmanufactured by Thomas & Betts,series 1490.
Series 4175Pipe Strap (EMT)
Series 1275/1275ALPipe Strap (Rigid Metal Conduit & I.M.C.)
Series 1350/1350ALPipe Spacer
(Rigid Metal Conduit I.M.C. & EMT) Series 3870Bonding & Grounding Bushing — Insulated
Series 106Bonding Locknut
Series 1490Entrance ELL
A-150
United StatesTel: 901.252.8000
800.816.7809Fax: 901.252.1354
Technical ServicesTel: 888.862.3289
www.tnb.com
Where service entrance cable is used as overhead service conductorsand code requires use of a service head, entrance caps shall beinstalled; caps shall be cast metal type of suitable ferrous or non-ferrous metal equipped with thermoset insulators and properknockout openings; caps when installed with proper drip loop mustensure raintight conditions.
At the point where the service cable enters the building, a suitable sill plate shall be provided; sill/wall plate shall be sealed to ensureraintight conditions.
Terminating fittings for serviceentrance cable (Type SE or USE) orunderground feeder and branch —circuit cable (Type UF) in locationswhere exposed to intermittent orconstant moisture or in drylocations and subjected tomechanical strain shall be ofwatertight strain relief type asmanufactured by Thomas & Betts,series 2111 or 2116; fittings shallbe constructed of ferrous or non-ferrous metal and equipped withtaper threaded hub, beveledmoisture resistant/oil resistantsynthetic rubber bushing.
In dry locations, nylon insulated two screw type fittings of malleableiron/steel construction electro zincplated inside outside, includingthreads such as series 3302Mmanufactured by Thomas & Bettsmay be substituted.
Gaskets
Where service entrance cable is terminated into a threadlessopening using hub type fittings, a gasket shall be provided betweenthe outside of box or enclosure and fitting shoulder; gasket shall beof moisture resistant/oil resistantsynthetic rubber type adequatelyprotected by and permanentlyretained to a metallic retainer asmanufactured by Thomas & Betts,series 5262.
Supports
Service entrance cable shall beadequately supported at intervalsenumerated in code using cablestraps conforming to requirementsof Canadian Standards AssociationStandard CSA 22.2 No. 18; cablestraps shall be of malleableiron/steel construction, hot-dippedgalvanized or electro zinc plated asmanufactured by Thomas & Betts,series 1341.
Service Entrance Cable Fittings
Series 3302MTwo Screw Connector (Insulated)
Series 2116Underground Feeder Cable Connector
Series 2111Service Entrance Cable Connector
Series 1341Cable Strap
Series 5262Sealing Gasket
A-151
United StatesTel: 901.252.8000
800.816.7809Fax: 901.252.1354
Technical ServicesTel: 888.862.3289
www.tnb.com
Service Entrance Cable Fittings
Application• To connect service entrance cables to a meter box
• Hot-dipped galvanizedmalleable iron construction
Oil- and water-resistant neoprene bushing specially designed for sealing around underground feeder cable!
Underground Liquidtight Feeder-Cable Fittings
Rocking action of foot allows each strap to accept a wide range of wire sizes!
Cable Straps
• Stainless steel retaining ring providesbearing surface for glandnut andeliminates cable twist
• Ribbed glandnut tightens easily withwrench to form high-strength connection
A-153
United StatesTel: 901.252.8000
800.816.7809Fax: 901.252.1354
Technical ServicesTel: 888.862.3289
www.tnb.com
Service Entrance Cable Fittings
Nylon UF Cable Fittings for Corrosive EnvironmentsCAT. HUB UF CABLE RANGE A B CNO. SIZE MAX. MIN. MAX. ± .060 ± .060
2827 1⁄2" .550 x .280 .400 x .190 2.60 1.270 .6002828 3⁄4" .675 x .280 .525 x .190 3.00 1.570 .6202829 3⁄4" .775 x .280 .625 x .190 3.00 1.570 .620
UL File No. 15170
CSA File No. 589
Nylon UF-Cable Fittings for CorrosiveEnvironments• Tapered threaded hub
• Liquid- and dust-tight
• Corrosion- and weather-resistantnylon construction for both outdoorand indoor applications
Watertight Connectors for Oval CableCAT. HUB OVAL CABLE RANGENO. SIZE MAX. MIN.
2111 1⁄2" .420 x .560 .380 x .5202232 3⁄4" .385 x .600 .260 x .5002233 3⁄4" .500 x .750 .375 x .6252234 3⁄4" .555 x .800 .490 x .6752432 1" .385 x .600 .260 x .5002433 1" .500 x .750 .375 x .6252434 1" .555 x .800 .430 x .6752438 1" .565 x .855 .440 x .7302439 1" .635 x .975 .510 x .8502442 11⁄4" .635 x .975 .510 x .8502443 11⁄4" .640 x 1.050 .490 x .9002446 11⁄4" .750 x 1.150 .565 x .9652454 11⁄2" .840 x 1.275 .655 x 1.0902447 11⁄2" .880 x 1.425 .695 x 1.2402448 2" .968 x 1.500 .790 x 1.3902449 2" 1.062 x 1.765 .850 x 1.5502450 2" 1.820 x 1.190 1.700 x 1.050
UL File No. E-15170
CSA File No. 589
NOTE: These may be obsoleted and replaced.
Two-taper design — one slow and one fast — enables connectors to accept varied cable sizes for maximum take-up!
Watertight Connectors for Oval Cable• Tapered neoprene bushings resist
oil, sunlight and water
• Hex gland and body take samewrench opening
• Stainless-steel slip ring preventscable from twisting as gland ring is tightened
• Threads on body tapered for water-sealing
Hand tightens —no tools required!
A-154
United StatesTel: 901.252.8000
800.816.7809Fax: 901.252.1354
Technical ServicesTel: 888.862.3289
www.tnb.com
Metal Clad Cable, Armored Cable and Flexible MetalConduit Fittings
NOTE
The materials herein, whether relating to the National Electrical Code, the Underwriters Laboratories, Inc. listing, to industry practice or otherwise, are not intended to provide all relevant information required for use and installation of our products. Refer to applicable codes, instructions and industry specifications prior to installation or use.
Metal Clad Cable, Armored Cable and Flexible Metal ConduitArmored Cable (Type AC) — Ref. NECArticle 320National Electrical Code defines type AC armoredcable as, “A fabricated assembly of insulatedconductors in a flexible metallic enclosure.”
ACT Indicates an armored cableemploying conductors havingthermoplastic (Type T) insulation.
AC Indicates an armored cableemploying conductors having rubber insulation of code grade.
ACH Indicates an armored cableemploying conductors having rubber insulation of the heatresistant (75° C) grade.
ACHH Indicates an armored cableemploying conductors having rubber insulation of the heatresistant (90° C) grade.
ACU Indicates an armored cableemploying conductors having rubber insulation of latex grade.
“L” Used as a suffix, it indicates that a lead covering has been appliedover the conductor assembly.
All armored cables may employ copper oraluminum or copperclad aluminum conductorswith the following sizes and are rated for 600 volts or less:
No. 14 AWG to No. 1 AWG Copper
No. 12 AWG to No. 1 AWG Aluminum or Copperclad Aluminum
Type AC cables except ACL carry an internalbonding strip of copper or aluminum in intimatecontact with the armor for its entire length.Armored cable can be used for both exposed or concealed locations. With lead-coveredconductors (Type ACL), the cable can beembedded in masonry or concrete and can beused in damp locations or where exposed to oil.
Armored cable is not permitted in locationswhere it will be subjected to physical damage or corrosive fumes. Armored cable cannot beused for direct burial in earth.
With minor exceptions, armored cable is alsonot permitted to be used in hoists or elevators,storage battery rooms, any hazardous locations,in commercial garages and in theaters or similarlocations.
Codes require that cable shall be supportedwith straps or staples without damagingconductors and also limit the minimum bendradius to 5 times the diameter of type AC cable.Certain precautions are prescribed in code wherecable is installed through joist rafters or similarwood members.
According to NEC 320 where armored cableis terminated, a fitting is required to protectconductors from abrasion. In addition, a bushingis required between the conductors and armor.Design of fitting has to be such that theinsulating bushing is visible for inspection.Bushing is not required with lead-covered cables when properly installed.
Series 3110Armored Cable Connector & Flexible Metal Conduit
Series 390Anti-Short Bushing
Suggested Specifications for Armored Cable and Flexible Metal Conduit Fittings• Armored cable (metal clad cable type
AC) and flexible metal conduit shallconform to provisions of followingapplicable standards:
Armored Cable…UL 4/ANSIC33.9/CSA 22.2 No. 51
Flexible Metal Conduit…UL 1/ANSIC33.92/WW-C-566/CSA 22.2 No. 56
Type of cable used and conductorswithin flexible metal conduit shallbe suitable for conditions of useand location.
• Where approved armored cable orflexible metal conduit is used as anequipment grounding conductor,terminating fitting used shall be ofthe grounding type as manufacturedby Thomas & Betts, series 3110
• Where armored cable or flexiblemetal conduit terminates into athreadless or threaded opening, itshall be assembled with approvedfittings; fittings shall be of malleableiron/steel construction, electro zinc plated inside outside, equipped withnylon insulated throat and shall be ofangled saddle type as manufacturedby Thomas & Betts, series 3110.Direct bearing screw type fittingsshall not be used
• Suitable bushing as manufacturedby Thomas & Betts, series 422 or 390, shall be provided betweenthe conductors and armor
Metal Clad Cable, Armored Cable and Flexible Metal Conduit — continuedFlexible Metal Conduit — Ref. NEC Article 348Flexible metal conduit can be used for exposedor concealed work in dry locations. It can beused for wet locations provided conductorswithin are lead covered or other approved type.
Flexible metal conduit cannot be usedunderground or embedded in poured concrete or aggregate. With rubber covered conductors,the conduit cannot be exposed to oil, gasoline or other materials having a deteriorating effecton rubber.
With minor exceptions use of flexible metalconduit is not permitted in hoists, in storagebattery rooms and in any hazardous locations.Use of flexible metal conduit is restricted tosystems under 600 volts.
According to NEC Article 350-5, flexible metalconduit no longer than six feet and containingcircuit conductors protected by overcurrentdevice rated for 20 amps or less is suitable as a grounding means provided, it is terminatedin fittings approved for the purpose.
Flexible metal conduit longer than six feet is permitted to be used as a grounding meansprovided the conduit and the fitting are approvedfor the purpose. To date, there is no flexiblemetal conduit approved for the purpose by the Underwriters Laboratories.
In Class I & II, Division 2 hazardous areas, theconduit itself cannot be used as the groundingmeans. A bonding jumper must be installed inaccordance with NEC Section 250.102. Flexiblemetal conduit is available with steel or aluminumarmor in trade size 5⁄16" to 4". With few exceptionswhere 5⁄16" and 3⁄8" trade sizes are used, Codeprohibits use of conduit less than d" trade size.Bends in concealed work are restricted to 360degrees total. No angle connectors are permittedin concealed raceway installations.
Metal Clad Cable, Armored Cable and Flexible MetalConduit Fittings
A-156
United StatesTel: 901.252.8000
800.816.7809Fax: 901.252.1354
Technical ServicesTel: 888.862.3289
www.tnb.com
Metal Clad Cable, Armored Cable and Flexible MetalConduit Fittings
TITE-BITE® Connectors
3110 Series
Application• To connect and effectively bond metal
clad cables, armored cable or flexiblemetal conduit to a box or an enclosure
Features• Provided with an angled saddle
designed to:
(1) Firmly secure conduit in place withoutdamaging cable armor (Mechanicalholding power of angled wedge assemblyincreases with increased strain.)
(2) Provide high quality bond between conduitor cable and is unaffected by vibrations
• Insulated throat protects conductorsduring and after installation andreduces wire pull effort
• Heat-curled insulator in throat:
(1) Better protects conductors due to funnel entry
(2) Reduces pulling force due to rotating design
(3) Won’t pull out
• Locknuts designed to provide effectivebond between connector and box orenclosure, will not vibrate loose
• Designed with fewer installing screws — reduces installation time and labor cost
• Armor stop with viewing window
• Rugged all steel or malleable iron construction
• Suitable as a grounding means per NEC Article 348 for flexible metalconduit, NEC Article 320 for armoredcable and NEC Article 330 for metalclad cable
• Suitable for hazardous location use per Class 1 Division 2 NEC 501.10 (b)(2)
Material: Steel thru 3⁄4" trade size.UL File No. E 23018CSA File No. 2884#UL Listed for Metal Clad Cable (MCI).°UL Listed for new Interlocked Armor Ground Type Metal Clad Cable (MCI-A).*Good for aluminum-sheathed cable.**UL Listed for Armored Cable and Metal Clad Cable.***UL Listed for Flexible Metal Conduit only.†Approximate dimension with screw at minimum height.††CSA not applicable.
• Easy to install with double-grip saddle
• 3⁄8" and 1⁄2" sizes made of formed steel,which produces uniform high qualityand a smooth throat to protectconductor insulation
• 3⁄4" and larger size are malleable iron
CAT. CABLE OPENING (IN.) TRADE K.O. DIMENSIONS (IN.)NO. MAX. MIN. SIZE SIZE A† B C
Material: Steel thru 1⁄2" trade size.UL File No. E 23018CSA File No. 2884#UL Listed for Metal Clad Cable (MCI).°UL Listed for new Interlocked Armor Ground Type Metal Clad Cable (MCI-A).*Not UL Listed.**UL Listed for Armored Cable and Metal Clad Cable.***UL Listed for Flexible Metal Conduit only.†Approximate dimension with screw at minimum height.††CSA not applicable.
Designed to resist vibration and strain!
TITE-BITE® Connectors — Nylon-Insulated
Completely reusable!
TITE-BITE®
Connectors
A-158
United StatesTel: 901.252.8000
800.816.7809Fax: 901.252.1354
Technical ServicesTel: 888.862.3289
www.tnb.com
Metal Clad Cable, Armored Cable and Flexible MetalConduit Fittings
CABLE OPENING (IN.) TRADE K.O. DIMENSIONS (IN.)CAT. NO. MAX. MIN. SIZE SIZE A† B C
3130-TB#° .660 .470 3⁄8" 1⁄2" 111⁄32 119⁄3215⁄16
3132#° .920 .670 1⁄2" 1⁄2" 17⁄8 25⁄1615⁄16
3135# 1.093 .906 3⁄4" 3⁄4" 21⁄8 21⁄8 9⁄16
3137# 1.468 1.250 1" 1" 221⁄32 21⁄8 1⁄2
3138*** 1.750 1.562 11⁄4" 11⁄4" 35⁄16 39⁄329⁄16
3139*** 2.031 1.812 11⁄2" 11⁄2" 4 41⁄8 11⁄16
3140*** 2.500 2.312 2" 2" 415⁄16 51⁄1611⁄16
3141*** 3.062 2.812 21⁄2" 21⁄2" 69⁄32 6 3⁄4
3142*** 3.562 3.312 3" 3" 711⁄32 71⁄163⁄4
3143***†† 4.060 3.620 31⁄2" 31⁄2" — — —
3144-TB***†† 4.560 4.120 4" 4" — — —
CABLE OPENING (IN.) TRADE K.O. DIMENSIONS (IN.)CAT. NO. MAX. MIN. SIZE SIZE A† B C
TITE-BITE® design holds flexible metal cablefirmly in place with a single screw!
Adapter — EMT to Flex
A
B
C
SIZE DIMENSIONS (IN.)CAT. NO. FLEX TO EMT A B C
449-TB 3⁄8" - 1⁄2" 121⁄32 111⁄3215⁄16
One-piece fitting couples 3⁄8" flexible metal conduit to 1⁄2" EMT!
Combination Coupling
Cable opening: max. .656, min. .250. UL File No. E-23018
CSA File No. 2884
Smooth plastic bushing protectsconductor insulation fromrough edges of armored cableand flexible metal conduit!
Anti-Short Bushing
CAT. NO. SIZE
390 14-2, 14-3, 12-2391 14-4, 12-3, 6-1, and 4-1392 12-4, 10-2, 10-3 and 2-1393 10-4, 8-2, 8-3, and 1-1394 8-4, 6-2, 6-3, 4-2, 4-3, and 6-4Colorized.
Temperature Rating: 240° F.
CSA File No. 589
UL not applicable.
Fast and easy installation!
Strap
CAT. NO. SIZE
65-TB 3⁄8" Flex
• Elongated bolt hole makes alignment easy,even when holes in mounting surface are off center
• Snap-on design holds strap in place
A
B
C
A-161
United StatesTel: 901.252.8000
800.816.7809Fax: 901.252.1354
Technical ServicesTel: 888.862.3289
www.tnb.com
Non-Metallic Sheathed Cable Fittings
NOTE:
The materials herein, whether relating to the National Electrical Code, the Underwriters Laboratories, Inc. listing, to industry practice or otherwise, are not intended to provide all relevant information required for use and installation of our products. Refer to applicable codes, instructions and industry specifications prior to installation or use.
Non-Metallic Sheathed CableRef. NEC Article 336Code defines non-metallic sheathed cable as, “A factory assembly of two or more insulated conductors having an outer sheath of moisture resistant,flame retardant, non-metallic material.”
Non-metallic sheathed cable is constructed of insulated conductors (14 to 2 AWG Copper or 12 to 2 AWG Aluminum or Copperclad Aluminum),and an outer non-metallic sheath classified as Type NM or Type NMC.
Non-metallic sheathed cable is provided with or without a bare or insulatedequipment grounding conductor. Non-metallic sheathed cable is rated for 60° C service with voltage limitation of 600 volts.
Type NM — has flame-retardant moisture resistant sheath.
Type NMC — has flame-retardant, moisture-resistant, fungus-resistant and corrosion-resistant sheath.
Non-metallic sheathed cable is permitted by code to be used exposed or concealed in one, two or multifamily dwellings or other structures not exceeding three floors. Use of Type NM cable is restricted to drylocations where as Type NMC can be used in dry, moist, damp or corrosive environments.
Non-metallic sheathed cable (both Type NM & NMC) is not permitted to be used as a service conductor, in commercial garages, in hoists or cannot be embedded in cement, concrete or aggregate. With minorexceptions use of non-metallic sheathed cable is also prohibited in theaters or any hazardous locations.
NEC Section 336-5 requires that cable be secured in place by suitablemeans so as not to injure the cable. Adequate protection for cable is also required when run is exposed, through joists or rafters, through floors, in unfinished basements and accessible attics.
Cable bends are limited to a minimum of five times the diameter of the cable.
NEC 300-4(b) requires that cable be protected from physical damage whenit passes through factory or field punched, cut or drilled holes in metalmembers. A bushing or grommet firmly secured in place is recommended.
7. CSA C22.2 No. 48…Safety Standards for Non-Metallic Sheathed Cable
8. CSA C22.2 No. 18…Safety Standards for Outlet Boxes, Conduit Boxes and Fittings
A-162
United StatesTel: 901.252.8000
800.816.7809Fax: 901.252.1354
Technical ServicesTel: 888.862.3289
www.tnb.com
Non-Metallic Sheathed Cable Fittings
Series 3302MNon-Metallic Sheathed Cable and Flexible Cord Connectors (Steel)
Series 1942Insulated Nipples
Suggested Specifications for Non-Metallic Sheathed Cable Fittings• Where non-metallic sheathed cable or flexible cord terminates
into a threaded or threadless opening, terminating fittings used shall be approved for the purpose by nationally recognized laboratory, inspection agency or product evaluation organization.
• Terminating fittings shall be of malleable iron, steel or thermoplasticconstruction designed to provide adequate strain relief and positivelyprevent damage to jacket or conductor insulation such as series 3300or 3302M manufactured by Thomas & Betts.
Ferrous metal fittings shall be electro zinc plated inside/outsideincluding threads and bushed with a nylon insulated throat.
Thermoplastic material used for connector construction shall be ofhigh impact strength suitable for 105° C/221° F service with a ULflammability rating of 94V-1.
• Where non-metallic sheathed cable passes through either factory or field punched, cut or drilled holes in metallic members, the cable shall be protected by thermoplastic bushing such as series 3210manufactured by Thomas & Betts. Bushing shall be firmly secured in opening. Nylon bushed metallic fittings such as Thomas & Bettsseries 1942 may be substituted as required.
Series 3300Non-Metallic SheathedCable and Flexible CordConnectors (All Plastic)
A-163
United StatesTel: 901.252.8000
800.816.7809Fax: 901.252.1354
Technical ServicesTel: 888.862.3289
www.tnb.com
Series 3210Knockout Bushings
Non-Metallic Sheathed Cable Fittings
6. To remove from cable cut connector as shown.
Non-Metallic Sheathed Cable and Flexible Cord Connectors (All Plastic)
Typical Installation
1. Remove sheath from end ofcable (4" or more as required).Insert cable through connectoras shown (Cable under button).
4. Snap connector into knockoutbox. If desired, this step canbe done prior to Step 1.
5. To remove from knockout boxdepress ears.
Application• To connect non-metallic sheathed cable
and flexible cord to a box or an enclosure
Features• Design provides strain relief by partially
deflecting cable (A); therefore:
(1) Connector will not damage outer coveringor jacket of cable, or conductor insulation;designed to give safe trouble free installation
(2) Holding power and cable strain relief are not affected by surface finish of outer covering or cable jacket
(3) Connector provides superior holdingpower far in excess of listing agencyrequirements
• Snap-in one piece design; accommodatesvariation in knockout dimensions, savesinstallation time (B).
• All high-impact thermoplastic construction provides:
(1) Insulated throat; conductors are protected from abrasion
(2) Improved dielectric strength, and eliminates potential shorts
(3) Corrosion resistance
• Wide range — reduces inventories
• Connector may be pre-installed in box K.O. or on cable
Standard MaterialAll high-impact polycarbonate — UL Class 94V-1 suitable for 105° C application
Cable; also multiple (2) 12-2 and 14-2 Type NM Cable; .300" to.600" outside diameter cord
3202 3⁄4" 8-3 and 6-3 type NM cables; also Multiple (2) 14-3 and
10-2 Type NM Cable; .500" to .850" outside diameter cord
2. Insert button into cavity.
3. With grooved pliers, or parallel jawtype pliers (commercially available)squeeze button into cord or wiresas far into connector body aspossible. NOTE: It may be necessary to re-adjust pliers to ensure button is properly installed.
Steel or malleable iron.Two-Screw ConnectorsRounded cable grip and smooth bushing protect the cable sheath and wireinsulation. Because saddle is threaded, screws do not travel or extend beyond the connector body as it is clamped to the cable. An extra lip on the saddle closes the unused part of the connector opening.
• Threaded saddle means screws don’t travel or extend beyondconnector body as it’s clamped to cable
• Extra lip on saddle closes unused part of connector opening
• Steel or malleable iron construction
• Look for the unique T&B blue color ensuring the highest quality fitting
NON-INSULATED INSULATED UL LISTED & CSA CERTIFIED UL LISTED & CSA INSULATEDCAT. CAT. K.O. FOR THE FOLLOWING SINGLE (1) CERTIFIED FOR THE FOLLOWING IN. CABLE OPENING (IN.)NO. NO. SIZE AND PAIRS OF (2) NM & NMC CABLE SERVICE ENTRANCE CABLES A B C MAX. MIN.